TAG Number Steam Trap Placement Service Type ize [inch Connection Condition 1 NF-25-ME-074 Relating to EA-1506 EA-1506 FT 1 FL 12.3 345 1 2 NF-25-HD-026 Near GT-1511A Draining TD (LC) 1/2 SW 55 440 4 3 NF-25-HD-036 Near GT-1511A Draining TD (LC) 1/2 SW 55 440 6 4 NF-02-L2T-257 Tracing TD (LC) 1/2 SW 4.5 165 2 5 NF-21-L2D-198 Under NF-EA-1103 Draining TD (LC) 1/2 SW 4.5 165 2 6 NF-21-L2D-339 Under FA-1101A Draining TD (LC) 1/2 SW 4.5 165 5 7 NF-14-L2X-138 AT-1401 TD (LC) 1/2 SW 4.5 165 2 8 NF-22-L2X-230 AT-1201 TD (LC) 1/2 SW 4.5 165 6 9 NF-22-L2T-288 Tracing TD (LC) 1/2 SW 4.5 165 6 10 NF-25-L2T-208 Near NF-TV-1721 Tracing TD (LC) 1/2 SW 4.5 165 4 11 NF-24-L2T-252 Tracing TD (LC) 1/2 SW 4.5 165 2 12 NF-04-L2T-180 Near NF-PV-451B Tracing TD (LC) 1/2 SW 4.5 165 5 13 NF-23-L2X-222 TD (LC) 1/2 SW 4.5 165 6 14 NF-23-L2T-220 Near NF-PV-1306 Tracing TD (LC) 1/2 SW 4.5 165 4 15 NF-23-L2T-214 Near NF-PV-1204 Tracing TD (LC) 1/2 SW 4.5 165 6 TAG Number Steam Trap Placement Service Type ize [inch Connection Condition 16 NF-21-L2T-206 Near NF-PV-1103A Tracing TD (LC) 1/2 SW 4.5 165 5 17 NF-21-L2T-246 Near NF-PDT-1401 and NF-FG-240 Tracing TD (LC) 1/2 SW 4.5 165 5 18 NF-21-L2T-247 Near NF-PDT-1401 and NF-FG-240 Tracing TD (LC) 1/2 SW 4.5 165 5 Design Pressure [bar] Design Temp. [c] Under Pipe rack and Near tankyard and infront of FA-1505 Relating to AT-1401 in analyzer room (N5) Relating to AT-1201 and infront of NF-EA-1208 Near Pipe rack and above FV-1210 and Near NF-FT-1210 Near NF-SC-1404 and infront of NF- FA-1105A Near NF-PV-2306 and Relating to AT-2302 pressure reducing station AT- 1302PRS Design Pressure [bar] Design Temp. [c]

Upload: fkhajeh

Post on 17-Sep-2015

2 views

Category:

Documents


0 download

DESCRIPTION

this file is steam trap check list fore nf plant overhaules .

TRANSCRIPT

steam-trapTAG NumberSteam Trap PlacementServiceTypeSize [inch]ConnectionDesign Pressure [bar]Design Temp. [c]Condition1NF-25-ME-074Relating to EA-1506EA-1506FT1FL12.334512NF-25-HD-026Near GT-1511ADrainingTD (LC)1/2SW5544043NF-25-HD-036Near GT-1511ADrainingTD (LC)1/2SW5544064NF-02-L2T-257Under Pipe rack and Near tankyard and infront of FA-1505TracingTD (LC)1/2SW4.516525NF-21-L2D-198Under NF-EA-1103DrainingTD (LC)1/2SW4.516526NF-21-L2D-339Under FA-1101ADrainingTD (LC)1/2SW4.516557NF-14-L2X-138Relating to AT-1401 in analyzer room (N5)AT-1401TD (LC)1/2SW4.516528NF-22-L2X-230Relating to AT-1201 and infront of NF-EA-1208AT-1201TD (LC)1/2SW4.516569NF-22-L2T-288Near Pipe rack and above FV-1210 and Near NF-FT-1210TracingTD (LC)1/2SW4.5165610NF-25-L2T-208Near NF-TV-1721TracingTD (LC)1/2SW4.5165411NF-24-L2T-252Near NF-SC-1404 and infront of NF-FA-1105ATracingTD (LC)1/2SW4.5165212NF-04-L2T-180Near NF-PV-451BTracingTD (LC)1/2SW4.5165513NF-23-L2X-222Near NF-PV-2306 and Relating to AT-2302 pressure reducing stationAT-1302PRSTD (LC)1/2SW4.5165614NF-23-L2T-220Near NF-PV-1306TracingTD (LC)1/2SW4.5165415NF-23-L2T-214Near NF-PV-1204TracingTD (LC)1/2SW4.51656TAG NumberSteam Trap PlacementServiceTypeSize [inch]ConnectionDesign Pressure [bar]Design Temp. [c]Condition16NF-21-L2T-206Near NF-PV-1103ATracingTD (LC)1/2SW4.5165517NF-21-L2T-246Near NF-PDT-1401 and NF-FG-240TracingTD (LC)1/2SW4.5165518NF-21-L2T-247Near NF-PDT-1401 and NF-FG-240TracingTD (LC)1/2SW4.5165519NF-24-L2X-234Near NF-FV-1406B and analyzer roomAT-1411TD (LC)1/2SW4.5165220NF-24-L2D-253Near NF-FV-1403DrainingTD (LC)1/2SW4.5165521NF-25-L2D-203Near NF-FA-1506DrainingTD (LC)1/2SW4.5165522NF-24-L2T-251Near NF-FA-1401 and infront of NF-FA-1105BTracingTD (LC)1/2SW4.5165423NF-22-L2T-235Near NF-FA-1211TracingTD (LC)1/2SW4.5165724NF-02-L2T-262Near GAM-203ATracingTD (LC)1/2SW4.5165525NF-22-L2T-295Near GA-1202BTracingTD (LC)1/2SW4.5165626NF-22-L2T-297Near GA-1202BTracingTD (LC)1/2SW4.5165627NF-22-L2T-296Near GA-1202ATracingTD (LC)1/2SW4.5165228NF-21-L2D-340Near FA-1101A and infront of FB-301BDrainingTD (LC)1/2SW4.5165429NF-24-L2T-243infront of NF-FT-1416 and Near NF-PDT-1411TracingTD (LC)1/2SW4.5165430NF-24-L2T-244infront of NF-FT-1416 and Near NF-PDT-1411TracingTD (LC)1/2SW4.51654TAG NumberSteam Trap PlacementServiceTypeSize [inch]ConnectionDesign Pressure [bar]Design Temp. [c]Condition31NF-22-L2D-228infront of NF-EA-1208 and Near analyzer room (N2)DrainingTD (LC)1/2SW4.5165432NF-22-L2D-286infront of FA-1204DrainingTD (LC)1/2SW4.5165433NF-23-L2T-210Behind NF-GA-1301ATracingTD (LC)1/2SW4.5165734NF-21-L2T-200Behind NF-GA-1301ATracingTD (LC)1/2SW4.5165535NF-24-L2T-242Above NF-FA-1402 on 1st floorTracingTD (LC)1/2SW4.5165636NF-22-L2T-238Above NF-FA-1211 on 2nd floor and Near NF-FT-1205TracingTD (LC)1/2SW4.5165537NF-22-L2T-239Above NF-FA-1211 on 2nd floor and Near NF-FT-1205TracingTD (LC)1/2SW4.5165538NF-22-L2T-236Above NF-FA-1211 on 2nd floor and Near NF-FT-1203TracingTD (LC)1/2SW4.5165739NF-22-L2T-237Above NF-FA-1211 on 2nd floor and Near NF-FT-1203TracingTD (LC)1/2SW4.5165340NF-22-L2D-240Between NF-EA-1203 and NF-DA-1202DrainingTD (LC)1/2SW4.5165241NF-23-ME-079Relating to NF-EA-1312EA-2312FT3FL12.3345142NF-23-ME-081Relating to NF-EA-1302EA-2312FT3FL12.3345143NF-25-HG-037Relating to NF-GT-1511EA-2302TD (LC)3/4SW55440644NF-25-HD-035Near GA-1513ADrainingTD (LC)3/4SW55440445NF-07-L2D-169Under pipe rack and infront of NF-TV-1722 and Near NF-FT-706DrainingTD (LC)3/4SW4.51652TAG NumberSteam Trap PlacementServiceTypeSize [inch]ConnectionDesign Pressure [bar]Design Temp. [c]Condition46NF-25-L2H-201Relating to NF-FA-1507FA-2507FT3/4FL4.5165447NF-25-L2H-202Relating to NF-FA-1506fa-1506FT3/4FL4.5165748NF-25-L1D-097Near NF-GT-1511ADrainingTD (LC)3/4SW4.5350649NF-25-L1D-095Between NF-EA-1501A and NF-PV-1503DrainingTD (LC)3/4SW4.5350750NF-25-MD-073infront of NF-LV-1552DrainingTD (LC)3/4SW4.5345451NF-25-HD-028Near NF-PV-1722DrainingTD (LC)3/4SW55440752NF-25-HD-023at the right hand of NF-PV-2729 near NF-EA-2504ADrainingTD (LC)3/4SW55440253NF-25-HD-027at the right hand of NF-PV-1729 near NF-EA-1504ADrainingTD (LC)3/4SW55440254NF-25-L1D-096Near NF-GA-1513ADrainingTD (LC)3/4SW4.5350255NF-23-MD-078Near NF-FV-1309DrainingTD (LC)3/1SW12.3345756NF-23-MD-080Near NF-FV-1304DrainingTD (LC)3/4SW12.3345457NF-22-MD-082Near NF-FV-1202DrainingTD (LC)3/4SW12.3345458NF-22-MD-083Near analyzer room and infront of NF-EA-1208DrainingTD (LC)3/4SW12.3345459NF-25-MD-070behind NF-GA-1513BDrainingTD (LC)3/4SW12.3345260NF-25-MD-071behind NF-GA-1513BDrainingTD (LC)3/4SW12.33452

CONDITIONSYMBOL REMOVED2TDThemodynamicDISCONECTED3FTFloat & ThermostaticsFAIL IN OPEN POSITION4IBInverted BucketFAIL IN CLOSE POSITION5TSThermostaticNOT IN USE6 ACTION IN RAPID CYCLE7BODY HAS LEAKAGE8