  • SINTEF Materials and Chemistry 1

    Ole Øystein Knudsen, SINTEF

    www.smartpipe.com

    Continuous condition monitoring of pipelines and risers

  • SINTEF Materials and Chemistry 2

    • Technical condition• Warnings• Simulations• Visualisation

    Data interpretation

    • Materials degradation• Analysis tools• Database

    • Sensors• Communication• Power

    Decision making

    Data collection

  • SINTEF Materials and Chemistry 3

    General system requirements

    • No interference with laying operations• Non intrusive sensors• Low cost, simple, robust• Lifetime >20 years• Interfacing to existing sensor technology• Low power consumption• Local processing to reduce needed communication capacity

  • SINTEF Materials and Chemistry 4

    Lithiumbatteries

  • SINTEF Materials and Chemistry 5

    SmartPipe 

    Sensors• Ultrasound wall thickness 

    measurement• Strain gauges for measuring 

    deflection, vibration and internal pressure

    • Thermistor for temperature measurements

    • Accelerometer for measuring inclination

    Communication• Wireless electromagnetic signal in 

    coating

    Power• A package of conventional Lithium 

    batteries• Thermoelectric generator

  • SINTEF Materials and Chemistry 6

    Battery packing

    • Four cells in series inserted in steel tubes– 600 mm length– Space available for charge 

    balancing electronics– Hermetically sealed to prevent 

    water intrusion

    • Ten 14.4 V battery packs encased in exterior bracelet– 40 cells in total (120% capacity)– Close contact to cold sea water 

    beneficial for battery lifetime

    • Exterior bracelet can be partially embedded in PP‐insulation.

  • SINTEF Materials and Chemistry 7

    Communication

    • Electromagnetic wave in the coating

    • Inter node distance: 24 m• Redundancy distance: >200 m (8‐

    10 nodes)• Carrier frequency: 3.8 MHz• Output power +14 dBm• Band with: 150 kHz

    • Patented 

    Antenna

    Signal

    Multihop topography

    variable hop lengthintelligent end nodesdead nodes

    variable hop lengthsimple  nodes intelligent end nodes

  • SINTEF Materials and Chemistry 8

    SmartPipe data management

    Fibre modem or powerline modem

    Host machineData 

    collecion system

    Fibre modem or powerline modem

    Cab

    le o

    r opt

    ical

    fibr

    e

    Data base

    Sub-sea

    Fibre modem or powerline modem

    Pick-up antenna on outside of pipe

    Cable or optical fibre

    Degrada‐tion analysis

    Visuali‐sation tools

  • SINTEF Materials and Chemistry 9

    Test pipe: 216 m long 10" pipe 80 mm PP coating8 sensor and communication nodes

    Testing communication range and sensorsInstalled November 18, 2013 in the Orkanger fjord on 10‐15 m water depth 

    SmartPipe Meso test 

  • SINTEF Materials and Chemistry 10

    • Steel thickness = 9/16 i.e. 14.3mm• OD = 10 3/4• ID = 9 5/8

    The SmartPipe

  • SINTEF Materials and Chemistry 11

  • SINTEF Materials and Chemistry 12

    Antenna

  • SINTEF Materials and Chemistry

    • Communication at least 200 m along the pipe• Able to communicate with 8 nodes along the pipe• Attenuation of the communication signal is as expected or better 

    13

    Communication variable hop length

    intelligent end nodesdead nodesvariable hop length

    simple  nodes intelligent end nodes

  • SINTEF Materials and Chemistry

    • Pipe set in vibrational motion on land before the installation

    • Counting vibration half cycles in different strain ranges

    • Strain gauges mounted around the pipe as shown

    • 93 half cycles • Ax2 and Ax4 registered 92 and 93 half 

    cycles

    14

    Fatigue monitoring test

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    0 200 400 600 800 1000 1200Ra

    infall ha

    lf cycle coun

    tsAmplitude peak to peak (µ‐strain)

    0‐Hoop

    1‐Axial

    2‐Axial

    3‐Axial

    4‐Axial

    5‐Hoop

    Ax1

    Ax2

    Ax3

    Ax4

    H2

    H1

    Accelerometer

  • SINTEF Materials and Chemistry 15

    Temperature (SINTEF data log)

    Holes in data logged at SINTEF are caused by faulty 3G router and PC outages, not by faults in the SmartPipe system.

    The figure shows data from two of the four sensors at node 117

    All functional nodes and sensors show practically the same temperature with variation in the least significant bit only. This is as expected.

    Variation in temperature is probably cased by changes in water temperature due to tides, and weather conditions.

    Sensor 2 from last week only

    Sensor 1

    degrees C

  • SINTEF Materials and Chemistry

    Strain (SINTEF data log)The figure shows two of the six sensors at node 119

    • The strain values correlate with the temperature. This is as expected.• As expected the strain values do not change much over time (just a few μS)• The static strain value on each sensor element is more or less random and assumed to be caused by the 

    mounting procedure (stretching of belt etc)

    • Some sensors show some outliers that have been removed from these plots.

    microstrain

    Strain

    Temperature

    linear regression curve

  • SINTEF Materials and Chemistry 17

    Ultrasound thickness (SINTEF data log)The figure shows two of the eight sensors at node 119

    rising = more diffuse echo

    echo quality

    thickness

    unit 10µm13.080 mm

    • For most sensors the data shows a falling thickness and falling echo quality (rising quality number).• The mean change of thickness corresponds to 100um/year which is within expected range (steel in ocean water).• The echo quality is expected to fall as the steel surface corrodes.• Some sensors are more noisy than others but the averaged value seems to be correct.• Some sensors show outliers that have been removed from these plots. 

    12.475 mm

    linear regression curve

  • SINTEF Materials and Chemistry

    • Strain gauges• Ultrasound 

    18

    Laboratory testing of sensor resolution

  • SINTEF Materials and Chemistry

    • Tensile testing machine• Compressive mode• 10 to 250 kN• Calculated strain plotted vs measured 

    strain• 5% scaling deviation• Resolution better than 10 µ‐strain

    19

    Strain test

  • SINTEF Materials and Chemistry

    • Sensor belt mounted on steel panel

    • Grinded on the backside in ca 10 µm steps

    • Sensor measurement vs µm screw gauge

    • 180 µm grinded away• Average of 4 measurements has a 

    resolution better than 10 µm 

    20

    Wall thickness 

  • SINTEF Materials and Chemistry 21

    The consortium