contents 230 ryan way, south san francisco, ca, 94080 · rail & base mount terminal blocks...

33
RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series .250” and .300” Centers 4 NDN Series.375” and .635” Centers 5 N & NFT Series .197”, .281” and .390” Centers 6 NC, NSE & NSS Series 1.06” and .385” Centers 7 PLU & PSU Series .390” and .625” Centers 8 KT & PLK Series .250” and .390” Centers 9 NTQ, BNQ & BQQ Series .390” and .437” Centers 10 NDN Fuse Holders 11 UB Series Circuit Breakers 12 15188 Series .375” Centers; 30A, 600V 13 KU Series .625” Centers; 50A, 600V 14 DOUBLE ROW TERMINAL BLOCKS Magnum ® TB Series 100 .375” Centers; 20A, 300V 15 & 16 Magnum ® TB Series 200 .437” Centers; 20A, 300-600V 17 & 18 Magnum ® TB Series 300 .562” Centers; 20A-45A, 600V 19 & 20 Magnum ® TB Series 400 .687” Centers; 75A, 600V 21 Magnum ® TB Series Options Markings, Marker Strips, Covers 22 & 23 POWER TERMINAL BLOCKS QC Power Distribution .562” and .687” Centers; Ratings 40A, 250V and 70A, 600V 24 Barrier Terminal .968” Centers; Rating 115A, 600V 25 Dead Front Terminal .500” Centers; Rating 90A, 600V 25 Splicer Terminal .812” thru 2.687” Centers; Ratings to 620A, 250V 26 Power Distribution.812” thru 2.687” Centers; Ratings to 840A, 600V 27 Connector/Stud .812” thru 2.687” Centers; Ratings to 760A, 600V 28 Multiple-Input 1.78” Centers; Ratings 285A, 600V 29 MISCELLANEOUS Photo Control Receptacle 13661 Series 30 Non-Fused Disconnect ND-1260 Series 31 Contents Get the latest, most up-to-date specification data on products listed in this catalog by calling Bussmann Information Fax. BIF is a simple to use automated fax response system. No need to wait for normal business hours, BIF is available around the clock for your convenience. All you need is a touch-tone telephone and a fax machine to get specification data when you want it. A BIF document number is indicated with each product in this catalog. To get a detailed specification sheet simply call 314-527-1450 and follow the prompts. In a matter of minutes, a data sheet will be faxed to you. It’s that simple! © 1995 Cooper Industries, Bussmann Division Printed in U.S.A. Bussmann Information Fax ~ 414.527.1450 This catalog is intended to present product data and provide technical information that will help the end user with design application. Bussmann reserves the right, without notice, to change design or construc- tion of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this catalog. Once a product has been selected, it should be tested by the user in all possible applications.

Upload: others

Post on 29-Jul-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

RAIL & BASE MOUNT TERMINAL BLOCKS PAGESGeneral Specifications & Accessories

for Rail Mount Terminal Blocks 3NDN Series .250” and .300” Centers 4NDN Series.375” and .635” Centers 5N & NFT Series .197”, .281” and .390” Centers 6NC, NSE & NSS Series 1.06” and .385” Centers 7PLU & PSU Series .390” and .625” Centers 8KT & PLK Series .250” and .390” Centers 9NTQ, BNQ & BQQ Series .390” and .437” Centers 10NDN Fuse Holders 11UB Series Circuit Breakers 1215188 Series .375” Centers; 30A, 600V 13KU Series .625” Centers; 50A, 600V 14

DOUBLE ROW TERMINAL BLOCKSMagnum® TB Series 100 .375” Centers; 20A, 300V 15 & 16Magnum® TB Series 200 .437” Centers; 20A, 300-600V 17 & 18Magnum® TB Series 300 .562” Centers; 20A-45A, 600V 19 & 20Magnum® TB Series 400 .687” Centers; 75A, 600V 21Magnum® TB Series Options Markings, Marker Strips, Covers 22 & 23

POWER TERMINAL BLOCKSQC Power Distribution .562” and .687” Centers;

Ratings 40A, 250V and 70A, 600V 24Barrier Terminal .968” Centers; Rating 115A, 600V 25Dead Front Terminal .500” Centers; Rating 90A, 600V 25Splicer Terminal .812” thru 2.687” Centers; Ratings to 620A, 250V 26Power Distribution.812” thru 2.687” Centers; Ratings to 840A, 600V 27Connector/Stud .812” thru 2.687” Centers; Ratings to 760A, 600V 28Multiple-Input 1.78” Centers; Ratings 285A, 600V 29

MISCELLANEOUSPhoto Control Receptacle 13661 Series 30Non-Fused Disconnect ND-1260 Series 31

Contents

Get the latest, most up-to-date specification data on products listed in this catalogby calling Bussmann Information Fax.

BIF is a simple to use automated fax response system. No need to wait for normalbusiness hours, BIF is available around the clock for your convenience. All youneed is a touch-tone telephone and a fax machine to get specification data whenyou want it.

A BIF document number is indicated with each product in this catalog. To get adetailed specification sheet simply call 314-527-1450 and follow the prompts. In amatter of minutes, a data sheet will be faxed to you. It’s that simple!© 1995 Cooper Industries, Bussmann DivisionPrinted in U.S.A.

BussmannInformation Fax ~ 414.527.1450

This catalog is intended to present product data and provide technical information that will help the enduser with design application. Bussmann reserves the right, without notice, to change design or construc-tion of any products and to discontinue or limit distribution of any products. Bussmann also reserves theright to change or update, without notice, any technical information contained in this catalog. Once aproduct has been selected, it should be tested by the user in all possible applications.

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

Page 2: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

MAGNUM®

Electrical ProductsTerminal Blocks / Distribution Blocks / Quick Connect Blocks / Disconnects

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

Page 3: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

GET CONNECTED WITH US

ns

d

sh-

ge

at

nn

s.

is

en-

ty

gn

ee

re

-

nts

com-

t

re

L,

of

ti-

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

Bussmann Circuit Components

Bussmann Circuit Components has the most compl

selection of barrier style terminal blocks in North Americ

The MAGNUM® brand pioneered the development of hig

barrier, unbreakable single-row terminal strips for electric

electronic equipment. Accepted nationally, Magnum is

leader in the field of terminal blocks, boards or strips.

Molded of flexible, resilient thermoplastic which elimi

nates barrier and strip breakage and enables molding m

longer strips for convenience and utility, it is lighter tha

thermoset phenolic. Rated at 94VO,

also offers higher dimensional accurac

higher insulating quality and lower hea

absorption during wave soldering.

Complementing its full electronic

product line, BCC offers Double Row

Terminal Blocks, which are one of the

most widely used devices for terminat

ing wires. Versatile and cost effective

only a screwdriver is needed for installation, eliminating tim

consuming splicing. High den-

sity circuitry conserves panel

space with a variety of termina-

tion styles. Increased insulation

is provided to stop leakage and

short circuits. In the field, the

high costs of changes are

reduced by simply rearranging

wire. Other BCC terminal block products include junctio

blocks, power distribution blocks, sectional terminal block

35mm DIN Rail terminal blocks, I/O connectors and MAG

MASTER® interface systems.

The BCC design team is organized into three prod

areas: Terminal Blocks, Circuit Breakers and Custo

Products. Thus, we concentrate our efforts on creat

designs and practical solutions for customer needs. O

design engineers use state-of-the-art technology includ

advanced computer aided design techniques. Employ

high-tech methods enables BCC to rapidly transform des

ideas into working models, expedited by our in-house mo

shop. Prototypes are ready in weeks . . . not months.

ete

a.

h

al/

a

-

uch

n

it

y,

t

-

,

e

n

s,

-

uct

m

ive

ur

ing

ing

ign

del

BCC maintains a complete lab

facility for performing UL,

CSA & IEC qualification test-

ing. This saves time and money

by eliminating costly expenses

and procedures involved in

gaining approvals.

To keep in touch with ever-

changing industry advances,

BCC actively participates in respected industry organizatio

including NEMA, SAE, and UL. Our design engineers hol

positions on several committees that influence the establi

ment of industry standards.

Quality parts are produced by employees with an avera

of 10 years' experience with BCC. Employees take gre

pride in their workmanship and the success of Bussma

Circuit Components. Their strong work ethic along with

quality assembly equipment assures highly reliable product

The BCC commitment to quality parts and service

apparent throughout the production process. Our compreh

sive quality systems are based on the Total Quali

Management philosophy. They start with conceptual desi

and encompass every functional area of BCC. Employ

training, Continuous Quality Improvement Programs, Failu

Mode Effects Analysis (FMEA), CP and Cpk statistical meth

ods and the use of process and quality control docume

such as SPC are all used. These systems measure both

pany and supplier activities providing the framework tha

ensures quality products. ISO 9000 Quality Standards a

fully respected and current agency compliances include U

CSA, VDE, IEC and SAE. BCC has been the recipient

several quality assurance certifications including the pres

gious “Ford Q1” Award.

When searching for a

solution to your electronic

circuit protection or con-

nection needs, you can

rely on Bussmann Circuit

Components.

Get Connected With Us.

2

Page 4: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

Series NDN Rail Mount Terminal Blocks35mm DIN Rail Compatible

High density design: Up to 48 circuits per footClamping collar: Secures wiresLarge, captive, wire-ready screws: Speeds assemblySnap-on installation to DIN rail: Fast, easy assemblyFully shielded construction: 600V spacingsUnique one-piece construction: Increases reliabilityThermoplastic moldings: Strong and impact resistantMaterial: UL Recognized 94V-2 thermoplasticCollars: Heat treated stainless steelTerminals: Tin plated copper alloyScrews: Zinc plated steelApprovals: UL E62622; CSA LR15364;

CE Pending

NDNV4High Density

48 circuits per foot

NDN63Accepts wires larger

than standardcontrol circuits

NDNF1Single pole

fuseholder accepts13/32” x1-1/2”

fuses

NDN1/NDN111Heavy-duty

90 Amp block

NDN3Space saving

3-pole unit

NDNA200Universal aluminum

35mm DIN mounting rail

Series NDN Terminal Block Accessories

NDNA NDNAS NFTA NRA SOA72 MARKING JUMPERS35mm DIN rail 35mm DIN rail C-rail C-rail 72” long TAPE See series

Aluminum End Stop Aluminum Low profile Stand-Off Channel See series specificationsNDNA 100 1 meter Lengths to 72” No flange for C-rail specificationsNDNA 200 2 meters Aluminum

Lengths to 37-1/2”

BIF document: 1400

3 For complete specification data, call Bussmann Information Fax ~ 314.527.1450

Page 5: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

GET CONNECTED WITH US

Inches (Millimeters)

Rail Mount Terminal Blocks

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

NDNV4

SPECIFICATIONSRating: NDNV4 30A, 600V; UL/CSACenter spacing: .250” (6.35)Number of poles: 4Circuits per foot: 48Circuit jumper: JN4, 4 circuitsWire size: AWG #10-22 CUScrew size: #6-32Mounting options: 35mm DIN rail, C-railMarking tape: MTC6Torque rating: 18 in/lb max.Operating temperature: 105°C

For complete specification data, ca

1.23(31.24)

1.47(37.33)

1.67(42.41)

1.00(25.40)

MarkingTape

1.34(34.04)

Inches (Millimeters)

NDN3

SPECIFICATIONSRating: 30A - field wiring; 40A - factory wiring

600V; UL/CSACenter spacing: .300” (7.62)Number of poles: 3Circuits per foot: 38Circuit jumper: JNDN3, 2 circuitsWire size: AWG #10-22 CUScrew size: #6-32Mounting options: 35mm DIN rail, C-railMarking tape: MT12-1/2Torque rating: 18 in/lb max.Operating temperature: 105°C

ll Bussmann Information Fax ~ 314.527.14

1.47(37.33)

1.67(42.41)

1.31(33.27)

.94(23.87)

450

BIF document: 1401

Page 6: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

Rail Mount Terminal Blocks

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

NDN63

SPECIFICATIONSRating: 65A, 600V; UL/CSACenter spacing: .375” (9.52)Number of poles: 3Circuits per foot: 30Circuit jumper: JN3, 2 circuitsWire size: AWG #6-18 CUScrew size: #10-32Mounting options: 35mm DIN rail, C-railMarking tape: MT12-1/2Torque rating: 35 in/lb max.Operating temperature: 105°C

5 For comple

BIF document: 1402

Inches (Millimeters)

1.50(38.10)

1.67(42.41)

1.45(36.83)

1.17(29.71)

NDN1

SPECIFICATIONSRating: 90A, 600VCenter spacing: .635” (16.13)Number of poles: 1Circuits per foot: 18Wire size: AWG #2-18 CUScrew size: 1/4-28Mounting options: 35mm DIN rail, C-rail* Dove-tail option is available for mounting side-by-side. Order part no. NDN1-A.Marking tape: MT12-1/2Torque rating: 32 in/lb max.Operating temperature: 105°C

te

Inches (Millimeters)

.59(14.99)

DovetailOption

1.43(36.31)

1.71(43.48)

1.32(33.68)

NDN111

SPECIFICATIONSRating: 90A, 600V; UL/CSACenter spacing: .635” (16.13)Number of poles: 3Circuits per foot: 18Circuit jumper: JN1, 2 circuitsWire size: AWG #2-18 CUScrew size: 1/4-28Mounting options: 35mm DIN rail, C-rail, Base Mount. * Dove tail option is available for mounting side-by-side. Order part no. NDN111-A.Marking tape: MT12-1/2Torque rating: 32 in/lb max.Operating temperature: 105°C

.1.28

Inches (Millimeters)

1.87(47.50)

.62(15.75)

1.44(36.57)

1.71(43.48)

1.46(37.13)

Mtg. holes8 (4.57) dia.(7.11) c'bores

DovetailOption

specification data, call Bussmann Information Fax ~ 314.527.1450

Page 7: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

GET CONNECTED WITH US

Rail Mount Terminal Blocks

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

N512

SPECIFICATIONSRating: 5A, 600V; UL/CSA

20A, 300V; UL/CSACenter spacing: .197” (5.00)Number of poles: 12Circuits per foot: 60Circuit jumper: JN512, 12 circuitsWire size: AWG #12-22 CUScrew size: #4-48Mounting options: C-rail, 15mm DIN railMarking tape: AT512Torque rating: 12 in/lb max.Operating temperature: 105°C

.88(22.35)

For complete specification

Inches (Millimeters)

2.40(60.96)

1.09(27.68)

BIF document: 1403

NFT2

SPECIFICATIONSRating: 40A, 600V; UL/CSA;

55A Factory WiredCenter spacing: .281” (7.13)Number of poles: 2Circuits per foot: 38Circuit jumper: JN2, 2 circuitsWire size: AWG #8-22 CUScrew size: #8-32Mounting options: C-railMarking tape: MT12-1/2Torque rating: 18 in/lb max.Operating temperature: 105°C

Inches (Millimeters)

.60(15.44)

.65(16.51)

.07(1.78)

1.29(32.94)

.93(23.80)

1.68(42.82)

1.23(31.34)

.36(9.14)

BIF document: 1404

NFT3

SPECIFICATIONSRating: 40A, 600V; UL/CSA;

55A Factory WiredCenter spacing: .390” (9.91)Number of poles: 3Circuits per foot: 28Circuit jumper: JN3, 2 circuitsWire size: AWG #8-22 CUScrew size: #8-32Mounting options: C-railMarking tape: MT12-1/2Torque rating: 18 in/lb max.Operating temperature: 105°C

Inches (Millimeters)

1.18(29.97)

1.29(32.94)

1.23(31.37)

6 data, call Bussmann Information Fax ~ 314.527.1450

BIF document: 1405

Page 8: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

Rail & Base Mount Terminal Blocks

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

NC3

SPECIFICATIONSRating: 175A, 600V; UL/CSACenter spacing: 1.06” (26.92)Number of poles: 3Circuits per foot: 11Wire size: 2/0-#14 CU/ALScrew size: 5/16-24Mounting options: C-rail, Base MountMarking tape: MT12-1/2Torque rating: 45 in/lb max.Operating temperature: 105°C

BIF document: 1406

7

Inches (Millimeters)

3.12(79.38)

.250 x .190"mtg. slots

1.25(31.75)

1.75(44.45)

1.75(44.45)

Optional LS3 Terminal Cover

3.12(79.24)

NSE3

SPECIFICATIONSRating: 115A, 600V; UL/CSACenter spacing: 1.06” (26.92)Number of poles: 3Circuits per foot: 11Circuit jumper: JNSE3, 2 circuitsWire size: For use with wire crimpedto ring terminal.Screw size: 1/4-28Mounting options: C-rail, Base MountMarking tape: MT12-1/2Operating temperature: 105°C

Optional LS3 Terminal Cover

.250 x .190mtg. slots

BIF document: 1407

For co

Inches (Millimeters)

1.75(44.45)

1.53(38.86)

1.25(31.75)

NSS3

SPECIFICATIONSRating: 30A, 600V; UL/CSACenter spacing: .385” (9.77)Number of poles: 3Circuits per foot: 28Circuit jumper: JNSS3, 2 circuitsWire size: For use with wire crimpedto ring terminal.Screw size: #6-32Mounting options: C-railMarking tape: MT12-1/2Operating temperature: 105°C

BIF document: 1408

mp

Inches (Millimeters)

1.24(31.50)

1.25(31.75)

1.32(33.73)

lete specification data, call Bussmann Information Fax ~ 314.527.1450

Page 9: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

GET CONNECTED WITH US

Depluggable Rail Mount Terminal Blocks

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

PLU3

SPECIFICATIONSRating: 40A, 600V; UL/CSACenter spacing: .390” (9.91)Number of poles: 3Circuits per foot: 28Circuit jumper: JN3, 2 circuitsWire size: AWG #8-22 CUScrew size: #8-32Mounting options: C-rail, StackableMarking tape: MT12-1/2Torque rating: 18 in/lb max.Operating temperature: 105°C

For complete specification d

Inches (Millimeters)

1.25(31.75)

.59(14.98)

1.79(45.64)

1.85(46.99)

1.25(31.75)

1.25(31.75)

BIF document: 1409

PLU1 Series

SPECIFICATIONSRating: 70A, 600V; UL/CSACenter spacing: .625” (15.88)Number of poles: 1-3

PLU1 (1 pole)PLU11 (2 pole)PLU111 (3 pole)

Circuits per foot: 19Circuit jumper: JN1, 2 circuitsWire size: AWG #4-18 CUScrew size: 1/4-28Mounting options: C-rail, StackableMarking tape: MT12-1/2Torque rating: 32 in/lb max.Operating temperature: 105°C

ata, ca

Inches (Millimeters)

1.87(47.49)

1.85(46.99)

1.48(37.59)

1.25(31.75)

BIF document: 1410

PSU1 Series

SPECIFICATIONSRating: 45A*, 600V; UL/CSA*45A rating achieved with ring terminalcrimped to wire.Center spacing: .625” (15.88)Number of poles: 1-3

PSU1 (1 pole)PSU11 (2 pole)PSU111 (3 pole)

Circuits per foot: 19Wire size: For use with crimp onconnectors only.Screw size: #10-32Mounting options: C-rail, StackableMarking tape: MT12-1/2Torque rating: 32 in/lb max.Operating temperature: 105°C

(1

Inches (Millimeters)

.6255.88)

1.93(49.12)

2.44(62.10)

1.48(37.64)

1.30(33.00).43

(11.10)

BIF document: 1411

8ll Bussmann Information Fax ~ 314.527.1450

Page 10: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

Base Mount Terminal Blocks

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

KT3

SPECIFICATIONSRating: 40A, 600V; UL/CSACenter spacing: .390” (9.91)Number of poles: 3Circuits per foot: 28Circuit jumper: JN3, 2 circuitsWire size: #8-22 CUScrew size: #8-32Mounting options: Base Mount,StackableMarking tape: MT12-1/2Torque rating: 18 in/lb max.Operating temperature: 105°C

KADEnd Mount Adapter OptionalBIF document: 1412

9 Fo

Inches (Millimeters)

#8 screw clearance

KADend mtg.adapter

1.22(31.04)

1.25(31.75)

2.34(59.51)

1.25(31.75)

.25(6.35)

1.25(31.75)

1.87(47.63)

KT4

SPECIFICATIONSRating: 30A, 600V; UL/CSACenter spacing: .250” (6.35)Number of poles: 4Circuits per foot: 48Circuit jumper: JN4, 4 circuitsWire size: AWG #10-22 CUScrew size: #6-32Mounting options: Base MountMounting screws recommended every 12 circuits.Marking tape: MTC6Torque rating: 18 in/lb max.Operating temperature: 105°C

BIF document: 1413

r complete s

Inches (Millimeters)

1.34(34.04)

1.26(32.23)

.62(15.88)

.98(24.99)

.37(9.40)

PLK3

SPECIFICATIONSRating: 40A, 600V; ULCenter spacing: .390” (9.91)Number of poles: 3Circuits per foot: 28Circuit jumper: JN3, 2 circuitsWire size: AWG #8-22 CUScrew size: #8-32Mounting options: Base Mount,Stackable; End Piece (Part No. KAD)is required for mounting. Mountingscrews recommended every 15 circuits.Marking tape: MT12-1/2Torque rating: 18 in/lb max.Operating temperature: 105°C

BIF document: 1414

Inches (Millimeters)

1.46(37.22)

.56(14.22)

1.79(45.52)

1.84(46.86)

KADEnd Mount Adapter Required

pecification data, call Bussmann Information Fax ~ 314.527.1450

Page 11: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

GET CONNECTED WITH US

Quick Connect Terminal Blocks

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

NTQ23

SPECIFICATIONSRating: 40A, 600VCenter spacing: .390” (9.91)Number of poles: 3Circuits per foot: 28Wire size: AWG #8-22 CUScrew size: #8-32Mounting options: C-railMarking tape: MT12-1/2Torque rating: 18 in/lb max.Operating temperature: 105°C

For complete specification d

Inches (Millimeters)

1.25(31.75)

1.25(31.75)

1.25(31.75)

1.31(33.32)

BIF document: 1415

BNQ21

SPECIFICATIONSRating: 40A, 600V; UL/CSACenter spacing: .437” (11.10)Number of poles: 1Circuits per foot: 24Wire size: AWG #8-22 CUScrew size: #8-32Quick Connects: .250” x .031”Mounting options: Base Mount.,Stackable; End Piece (Part No. BQE)is required for mounting. Mounting screws recommended every 8 circuits.Torque rating: 18 in/lb max.Operating temperature: 105°C

(en

BQEEnd Mounting Adapter Required

A B

(N+2) x .437 (N+1) x .437

N = Number of circuits

Inches (Millimeters)

1.41(35.81)

.56(14.28)

#8 mtg.screw

#BQEd mtg. adaptor)

B

A

1.47(37.33)

BIF document: 1416

BQQ41

SPECIFICATIONSRating: 30A, 600V; UL/CSACenter spacing: .437” (11.10)Number of poles: 1Circuits per foot: 24Wire size: For use with quick connect terminals only.Quick Connects: .250” x .031”Mounting options: Base Mount,Stackable; End Piece (Part No. BQE)is required for mounting. Mounting screws recommended every 8 circuits.Operating temperature: 105°C

BQEEnd Mounting Adapter Required

(e

Inches (Millimeters)

1.41(35.81)

.56(14.28)

1.47(37.33)

B

A

#8 mtg.screw

#BQEnd mtg. adaptor)

BIF document: 1417

A B

(N+2) x .437 (N+1) x .437

N = Number of circuits

10ata, call Bussmann Information Fax ~ 314.527.1450

Page 12: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

Rail Mount Fuse Holders

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

NDNF1

SPECIFICATIONSRating: 30A, 600V; UL/CSANumber of poles: 1Fuse size: 13/32” x 1-1/2”BCC recommends BUSS® KTK-R, FNQ-Ror equivalent.Circuit jumper: JF1, 2 circuitsWire size: AWG #8-22 CUMounting options: 35mm DIN rail, C-railFuse Pullers: PF1 (standard);*LPF1 (lighted neon or incandescent bulb).Marking tape: MT12-1/2Torque rating: 18 in/lb max.Operating temperature: 105°C

1.25(31.7

2.00(50.80)

PF1Fuse Puller

LPF1Lighted Fuse Puller

11 For com

NDND1 non-fused disconnect e

NDNFD1 fused disconnect bloc

Inches (Millimeters)

.62(15.74)

.46(11.68)

1.93(49.02)

5)

nables isolation of individual circuits for testing

k

SPECIFICATIONSRatings:

NDND1: 30A, 600V; UL/CSANDNFD1: 15A, 600V; CSANDNLFD1: 15A, 600V

Number of poles: 1Fuse size: 1/4” x 1-1/4”BCC recommends BUSS® AGC, MDL or equivalent.Circuit jumper: JF1, 2 circuitsWire size: AWG #8-22 CUMounting options: 35mm DIN rail, C-railMarking tape: MT12-1/2Torque rating: 18 in/lb max.Operating temperature: 105°C

NDNLFD1 fused disconnect with visual indicator* f

1.25(31.75

*Visual indicator for blown fuse is neon or incandesce

BIF document: 1418

or blown fuse Inches (Millimeters)

)

2.31(58.67)

2.06(52.32)

.62(15.74)

2.68(68.07)

nt bulb, depending on voltage. Specify voltage required.

plete specification data, call Bussmann Information Fax ~ 314.527.1450

Page 13: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

GET CONNECTED WITH US

Rail Mount Circuit Breakers

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

UB Series

SPECIFICATIONSRating: .5 - 15A, 250VAC/65VDC; UL*/CSA/VDE*For 9A - 15A units, UL voltage ratings: 125VAC/65VDCNumber of poles: 1Max. interrupt cap.: 200A, but not over 100 times rated current.Life: 4,000 cyc. 200% rated current; 6,000 cyc. rated currentDielectric strength: 1,500VACInsulation resist: 100 MegohmsMounting options: 35mm DIN rail, C-rail (Adapter required for C-rail)Weight: 3.2 oz.

For complete specification data, call Bussmann Information Fax ~ 314

Inches (Millimeters)

UBA-CR(Req'd for C-rail mtg.)

.56(14.43)

1.37(35.04)

2.33(59.18)

3.13(79.60)

.45(11.56)

Part Numbering System

■■■■■■■■■■ – ■■Series Amperage

005 – 150(.5A – 15A)

U B U

Tripping Times in Seconds at 70°F

Percent rated current 100% 200% 300% 400% 500% 600% 1000% 2000%Tripping time no trip 10 - 40 3 - 18 1.5 - 9 .8 - 6 .003 - 4 .003 - 2 max. .02For elevated ambient temperatures, find proper current rating of circuit breaker by multiplying actual full load current with these factors. Select closest (higher) amp rating.Temperature 100°F (37.8°C) 120°F (48.9°C) 140°F (60°C) 160°F (71.1°C)Factor 1.1 1.2 1.3 1.4

Standard Current Ratings

Notes: Pressure connector is UL/CSA Recognized for field wiring.Contact factory for ratings below 1A.

Amps Ohms

0.5 8.0001.0 1.9001.5 0.9002.0 0.4802.5 0.3203.0 0.2603.5 0.1604.0 0.1304.5 0.0855.0 0.0765.5 0.064

Amps Ohms

6.0 0.0566.5 0.0357.0 0.0368.0 0.0329.0 0.02210.0 0.01811.0 0.01612.0 0.01613.0 0.01614.0 0.01215.0 0.012

BIF document: 1419

12.527.1450

Page 14: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

Series 15188Disconnect Terminal Blocks for 35mm DIN Rail Mount

SPECIFICATIONSRating: 30A; 600V*Center spacing: .375” (9.52 mm)Wire Size: AWG #12–16 CUScrew Size: #6-32 zinc plated philslotNumber of poles: 3 and 4 pole onlyMounting: 35mm DIN Rail Optional End Stop NDNAS (shown on pg 4).Jumpers: 2 through 4-pole availableMaterials: Molded Base: Black, UL rated 94V-2thermoplastic. Tin plated copper alloy contacts.Torque rating: 12 in/lb max.Operating temperature: 120°CApprovals: UL E62622; CSA LR15364; CE Pending

Assembly* ORIENTATIONReverse In-Line

3 Pole 15188-3R 15188-34 Pole 15188-4R 15188-4

* Includes male and female disconnect terminal blockassembly.

Photo courtesy of Square D Company.

*60A rating achieved with #10AWG wire crimped to ring terminal;25A without.

13

BIF documen

IN-LINE WIRING DIRECTION

1.94(49.27)

3 Pole = 1.19 (30.22)4 Pole = 1.56 (39.62)

REVERSE WIRING DIRECTION

1.94(49.27)

.375(9.52)

.22(5.58)

3 Pole = 1.19 (30.22)4 Pole = 1.56 (39.62)

For complete specification data, call Bussmann Information Fax ~ 314.527.1450

t: 1420

Page 15: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

No. of KU KUX onlyPoles A B A

2 2.50 1.62 2.003 3.12 2.25 2.624 3.75 2.87 3.255 4.37 3.50 3.876 5.00 4.12 4.507 5.62 4.75 5.128 6.25 5.37 5.759 6.87 6.00 6.37

10 7.50 6.62 7.0011 8.12 7.25 7.6212 8.75 7.87 8.25

Series KUBase Mount Double Row Terminal Blocks

SPECIFICATIONSRating: 60A, 600V*Center Spacing: .625” (15.88 mm)Number of poles: 2 - 12Wire Size: AWG #6 CU max.Screw Size: #10-32 brass nickel platedTorque Rating: 20 in/lb max.Distance Between Barriers: .437” (11.09 mm)Mounting: Base mount. For 35mm DIN rail mountable, consult factory.Material: Molded base: Black, UL rated 94V-0 thermoplastic. Terminal plating: Nickel over brass. Screws: Nickel plated brass.Operating Temperature: 105°C max.Approvals: UL E62622; CSA LR15364; CE Pending

#c

Dimensions in inches. To convert to millimeters, multiply by 25.4.

*60A rating achieved with #6 copper wire crimpedto ring terminal

For complete specification data, call Bussmann

GET CONNECTED WITH US

KU12

1.25(31.75)

A

B

10 screwlearance

.62(15.88)

1.50(38.10)

2.00(50.80)

.43(11.09)

.50(12.70)

KUSC4

Accessories

MTMU##Molded Marking Tape

Matte Finish

NUM##Molded

Marking Tape

JU12Jumper

12 Circuits

NUEEnd Piece for NUC

NUC##Cover

Part Numbering System

Series Poles Screw Options Covers Marking Strip

■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■ ■■■■■■■■ ■■■■■■■■ ■■■■■■■■■■■■KU - Standard block 2 to 12 00 - screws shipped bulk WC - Top cover & MT - Matte finishKUX - Short block W - brass washer head, 2 end plates NU - Numbered 1 to 12,KUSC - Standard w/shorting strap nickel plated horizontal

& 4 shorting screws P - Steel screw w/pressure plate NUV - Numbered 1 to 12,KURL - Standard w/removable link zinc plated verticalKUXSC - Short block w/shorting strap B - brass washer head, no plating PT - Marker strip for cover

& 4 shorting screwsKUXRL - Short block w/removable link

K U

BIF document: 1421

14 Information Fax ~ 314.527.1450

Page 16: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

Poles A B Poles A B Poles A B

02 1.40 1.12 14 5.90 5.62 26 10.40 10.1203 1.78 1.50 15 6.28 6.00 27 10.78 10.5004 2.16 1.88 16 6.66 6.38 28 11.16 10.8805 2.53 2.25 17 7.03 6.75 29 11.53 11.2506 2.90 2.62 18 7.40 7.12 30 11.90 11.6207 3.28 3.00 19 7.78 7.50 31 12.28 12.0008 3.66 3.38 20 8.16 7.88 32 12.66 12.3809 4.03 3.75 21 8.53 8.25 33 13.03 12.7510 4.40 4.12 22 8.90 8.62 34 13.40 13.1211 4.78 4.50 23 9.28 9.00 35 13.78 13.5012 5.16 4.88 24 9.66 9.38 36 14.16 13.8813 5.53 5.25 25 10.03 9.75

Series TB100Double Row Terminal Blocks

SPECIFICATIONSRating: UL: 20A, 250V*

CSA: 20A; 150V*Center Spacing: .375” (9.52 mm)Wire Size: #14 - 22 AWG CUScrew Size: #6-32 zinc plated philslot screwsTorque Rating: Max. torque for #6 screws - 9 in/lb.Distance Between Barriers: .30” (7.62 mm)Mounting: #6 screwsMaterials: Molded base: Black, UL rated 94V-0 thermoplasticTerminal plating: Tin over brass; Screws: Zinc plated steel finished with a clear chromate and special coating to inhibit rust.Hardware: Tin over brassOperating Temperature: 260°F (130°C) max., -40°F (-40°C) min.Creepage Paths: Terminal-to-terminal .275” (6.99 mm);Terminal-to-mounting surface .300” (7.62 mm).Breakdown Voltage: 3600V rmsApprovals: UL E62622; CSA LR15364; IEC Compliance; CE Pending* Max. rating shown; some options may be rated lower - consult factory.

.14(3.50)

.31 (7.90

.25 (6.30

* Dimensions in inches. To convert to millimeters, multiply by 25.4.

TB10

15 For complete specification data,

BIF document: 1422

.37(9.50)

.30(7.60).17 dia.

(4.30)

.14(3.50)

.88(22.30)

.41(10.40)

)

A

B

)

Inches (mm)

0

Part Numbering System

Series Poles Screw Options Marking Hardware Options

■■■■■■■■■■■■■■■■■■■■ - ■■■■■■■■ ■■■■■■■■ ■■■■■■■■ ■■■■■■■■■■■■■■■■02 to 36 Blank - std. screws L1 to L6 - std. marking QC1 to QC20 - quick connects

00 - screws shipped bulk Marker strips (pg 23)B - brass philslot, nickel plated Covers (pg 22)BS - brass Sems philslot, nickel platedSP - steel Sems philslot, zinc plated

T B 1 0 0

call Bussmann Information Fax ~ 314.527.1450

Page 17: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

GET CONNECTED WITH US

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

Screw Options

BBrass PhilslotNickel Plated

BSBrass SEMS

Philslot Nickel Plated

SPSteel SEMS

Philslot Zinc Plated

Hardware Options

QC8 QC9 QC11QC10 QC12 QC13

QC7

QC20

Quick Connects – Assembled Terminals .187” x .020”. Max. current rating 13 Amps. For other orientations,contact factory.

QC1 QC2 QC4QC3 QC5 QC6

QC17 QC18 QC19QC14 QC15 QC16

QC108QC 45° – QC 90°

QC105Flat – QC 45°

QC109QC 90° – QC 90°

J101Flat slip-on

OJ4Closed over barrier

OJ2Slip-on over barrier

Quick Connects – Bulk Min. order per part no. – 100 pieces.

Jumpers – Bulk .020” thick tin plated brass. Min. order per part no. – 100 pieces. Contact factory for jumper assembly.

QC102QC 45° – none

QC101Flat – none

QC103QC 90° – none

QC104Flat – Flat

QC107QC 45° – QC 45°

QC106Flat – QC 90°

16For complete specification data, call Bussmann Information Fax ~ 314.527.1450

Page 18: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

TB200

TB200HB

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

Poles A B Poles A B Poles A B

02 1.63 1.31 12 6.00 5.68 22 10.37 10.0603 2.07 1.75 13 6.44 6.12 23 10.81 10.5004 2.51 2.18 14 6.87 6.56 24 11.25 10.9305 2.94 2.62 15 7.31 7.00 25 11.68 11.3706 3.38 3.06 16 7.75 7.43 26 12.12 11.8107 3.82 3.50 17 8.19 7.87 27 12.56 12.2508 4.25 3.93 18 8.62 8.31 28 13.00 12.6809 4.69 4.37 19 9.06 8.75 29 13.44 13.1210 5.13 4.81 20 9.50 9.18 30 13.87 13.5611 5.57 5.25 21 9.94 9.62

Series TB200 & TB200HBDouble Row Terminal Blocks

SPECIFICATIONSRating: TB200 – 20A, 300V*

TB200HB – 20A, 600V*Center Spacing: .437” (11.10 mm)Wire Size: #12 - 22 AWG CUScrew Size: #6-32 zinc plated philslot screwsTorque Rating: Max. torque for #6 screws - 9 in/lb.Distance Between Barriers: .353” (8.97 mm)Mounting: #6 screwsMaterials: Molded base: Black, UL rated 94V-0 thermoplasticTerminal plating: Tin over brass; Screws: Zinc plated steel finished with a clear chromate and special coating to inhibit rustHardware: Tin over brassOperating Temperature: 260°F (130°C) max., -40°F (-40°C) min.Creepage Paths: Terminal-to-terminal .400” (10.16 mm);Terminal-to-mounting surface .375” (9.52 mm)Breakdown Voltage: 4800V rmsApprovals: UL E62622; CSA LR15364; IEC Compliance; CE Pending* Max. rating shown; some options may be rated lower - consult factory.

.16(4.00)

.44 (11.20)

.31 (7.80)* Dimensions in inches. To convert to millimeters, multiply by 25.4.

TB200

17 For complete specification data,

.

.

.43(11.10)

.35(8.90)

.17 dia.(4.30)

.16(4.00)

1.12(28.40)

.56(14.20)

A

B

.16(4.00)

.43(11.10)

.35(8.90)

.17 dia.(4.30)

.17 x .22 slots(4.30 x 5.60)

.16(4.00)

1.37(34.80)

.90(22.80)

.75(19.00)

44 (11.20)

A

B

33 (8.40)

Inches (mm)

TB200HB

Part Numbering System

Series Poles Screw Options Marking Hardware Options

■■■■■■■■■■■■■■■■■■■■ - ■■■■■■■■ ■■■■■■■■ ■■■■■■■■ ■■■■■■■■■■■■■■■■200 02 to 30 Blank - std. screws L1 to L6 - std. marking QC1 to QC20 - quick connects200HB 00 - screws shipped bulk Marker strips (pg 23)

B - brass philslot, nickel plated Covers (pg 22)BS - brass Sems philslot, zinc platedSP - steel Sems philslot, zinc plated

T B

BIF document: 1423

call Bussmann Information Fax ~ 314.527.1450

Page 19: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

GET CONNECTED WITH US

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

Screw Options

BBrass PhilslotNickel Plated

BSBrass SEMS

Philslot Zinc Plated

SPSteel SEMS

Philslot Zinc Plated

Hardware Options

Quick Connects – Assembled Terminals .250” x .031”. Max. current rating 24 Amps. For other orientations,contact factory.

QC8 QC9 QC11QC10 QC12 QC13

QC7

QC20

QC1 QC2 QC4QC3 QC5 QC6

QC17 QC18 QC19QC14 QC15 QC16

J201Flat slip-on

(Not availableon TB200HB)

OJ7Closed over barrier

OJ3Slip-on over barrier

Jumpers – Bulk .020” thick tin plated brass. Min. order per part no. – 100 pieces. Contact factory for jumper assembly.

QC208QC 45° – QC 90°

QC205Flat – QC 45°

QC209QC 90° – QC 90°

Quick Connects – Bulk Min. order per part no. – 100 pieces.

QC202QC 45° – none

QC201Flat – none

QC203QC 90° – none

QC204Flat – Flat

QC207QC 45° – QC 45°

QC206Flat – QC 90°

18For complete specification data, call Bussmann Information Fax ~ 314.527.1450

Page 20: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

Poles A B Poles A B Poles A B

02 2.13 1.69 10 6.62 6.19 18 11.12 10.6803 2.69 2.25 11 7.18 6.75 19 11.68 11.2504 3.25 2.81 12 7.75 7.31 20 12.24 11.8105 3.81 3.37 13 8.31 7.87 21 12.80 12.3706 4.37 3.94 14 8.87 8.44 22 13.37 12.9307 4.94 4.50 15 9.43 9.00 23 13.93 13.5008 5.50 5.06 16 9.99 9.56 24 14.49 14.0609 6.06 5.62 17 10.56 10.12

Series TB300 & TB345Double Row Terminal Blocks

SPECIFICATIONSRating: TB300 – 30A, 600V*

TB345 – 45A, 600V*Center Spacing: .562” (14.28 mm).Wire Size: #10 - 22 AWG CUScrew Size: TB300 – #8-32 zinc plated philslot screws

TB345 – #10-32 zinc plated philslot screwsTorque Rating: Max. torque for #8 screws - 16 in/lb; #10 screws - 20 in/lb.Distance Between Barriers: .412” (10.46 mm)Mounting: #10 screwsMaterial: Molded base: Black, UL rated 94V-0 thermoplasticTerminal plating: Tin over brass; Screws: Zinc plated steel finished with a clear chromate and special coating to inhibit rustHardware: Tin over brassOperating Temperature: 260°F (130°C) max., -40°F (-40°C) min.Creepage Paths: Terminal-to-terminal .500” (12.70 mm);Terminal-to-mounting surface .450” (11.43 mm)Breakdown Voltage: 7500V rmsApprovals: UL E62622; CSA LR15364; IEC Compliance; CE Pending* Max. rating shown; some options may be rated lower - consult factory.

.22(5.60)

.56(14.20)

.21dia.

.50 (12.70)

* Dimensions in inches. To convert to millimeters, multiply by 25.4.

TB300

19 For complete specification data

.

BIF document: 1424

.56(14.20)

.41(10.40)

(5.30)

.21 x .25 slots(5.30 x 6.30)

1.33(33.80)

.90(22.80)

.81(20.50)

A

B

8-32 binding head screw - TB 30010-32 binding head screw - TB 345

33 (8.40)

Inches (mm) & TB345

Part Numbering System

Series Poles Screw Options Marking Hardware Options

■■■■■■■■■■■■■■■■■■■■ - ■■■■■■■■ ■■■■■■■■ ■■■■■■■■ ■■■■■■■■■■■■■■■■300 02 to 24 Blank - std. screws L1 to L6 - std. marking QC1 to QC20 - quick connects345 00 - screws shipped bulk Marker strips (pg 23) (TB300 only)

B - brass philslot, nickel plated Covers (pg 22)BS - brass Sems philslot, zinc plated

(TB300 only)SP - steel Sems philslot, zinc plated

T B

, call Bussmann Information Fax ~ 314.527.1450

Page 21: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

GET CONNECTED WITH US

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

Screw Options

BBrass PhilslotNickel Plated

BSBrass SEMS

Philslot Zinc Plated

SPSteel SEMS

Philslot Zinc Plated

Hardware Options

Quick Connects – Assembled *TB300 only. Terminals .250” x .031”. Max. current rating 24 Amps. For other orientations,contact factory.

QC8 QC9 QC11QC10 QC12 QC13

QC7

QC20

QC1 QC2 QC4QC3 QC5 QC6

QC17 QC18 QC19QC14 QC15 QC16

J301Flat slip-on

(TB300 only)

OJ6Closed over barrier

OJ11Slip-on over barrier

Jumpers – Bulk .020” thick tin plated brass. Min. order per part no. – 100 pieces. Contact factory for jumper assembly.

QC208QC 45° – QC 90°

QC205Flat – QC 45°

QC209QC 90° – QC 90°

Quick Connects – Bulk *TB300 only. Min. order per part no. – 100 pieces.

QC202QC 45° – none

QC201Flat – none

QC203QC 90° – none

QC204Flat – Flat

QC207QC 45° – QC 45°

QC206Flat – QC 90°

20For complete specification data, call Bussmann Information Fax ~ 314.527.1450

Page 22: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

Poles A B Poles A B Poles A B

02 2.51 2.06 06 5.26 4.81 10 8.01 7.5603 3.20 2.75 07 5.95 5.50 11 8.70 8.2504 3.89 3.44 08 6.64 6.19 12 9.39 8.9405 4.58 4.13 09 7.33 6.88

Series TB400Double Row Terminal Blocks

SPECIFICATIONSRating: 75A, 600V** 30A max. with #10 AWG; 75A max. achieved with #4 AWG wire crimped to ring terminal.Center Spacing: .687” (17.45 mm)Wire Size: #10 - 14 AWG CUScrew Size: #10-32 zinc plated philslot screwsTorque Rating: Max. torque for #10 screw - 20 in/lb.Distance Between Barriers: .562” (14.27 mm)Mounting: #10 screwsMaterial: Molded base: Black, UL rated 94V-0 thermoplasticTerminal plating: Tin over brass; Screws: Zinc plated steel finished with a clear chromate and special coating to inhibit rustOperating Temperature: 260°F (130°C) max., -40°F (-40°C) min.Creepage Paths: Terminal-to-terminal .598” (15.19 mm);Terminal-to-mounting surface .542” (13.77 mm)Breakdown Voltage: 7500V rmsApprovals: UL E62622; CSA LR15364; IEC Compliance; CE Pending

.15 dia.(3.80)

* Dimensions in inches. To convert to millimeters, multiply by 25.4.

TB400

* 75A max acheived with #4 AWG wire crimped to ring terminal; 30A max. with #10 AWG.

21 For complete specification data

.68(17.40)

.22(5.60)

A'

A'

A

B

A' - A'

.625(15.90)

.1.12(28.40)

.68(17.40)

.56(14.30)

1.81(46.00)

.76(19.30).46 (11.70)

1.34(34.00)

.22 dia. (5.60)

Closed bottom

Inches (mm)

Screw Options

BBrass PhilslotNickel Plated

Part Numbering System

Series Poles Screw Options Marking Hardware Options

■■■■■■■■■■■■■■■■■■■■ - ■■■■■■■■ ■■■■■■■■02 to 12 Blank - std. screws Not available Not available

00 - screws shipped bulkB - brass philslot, nickel plated

T B 4 0 0

BIF document: 1425

, call Bussmann Information Fax ~ 314.527.1450

Page 23: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

All Series Marking Options & AccessoriesDouble Row Terminal Blocks

GET CONNECTED WITH US

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

Marking Options

Special Marking

Special markings are available at an additional charge forpreparation. Production charges for setup, handling andmarking are the same as for standard marking. Drawing(s)must be submitted to ensure accuracy of part required.Consult factory for price and delivery.

Standard Marking

Standard markings are applied directly to the side(s) of ablock. Standard color is white. Standard height is .125”.

Note: Blocks marked on both sides require a differentcode for each side. Example Style L1 on one side of theblock requires Style L2 on the other side to ensure com-mon terminal marking. To order, add appropriate suffix(L1, L2, L3, L4, L5 and/or L6) to block part number in theproper sequence.

Note: Not available on TB400 Series

For complete specification data, call Bussmann In

1 2 3 3 2 1

3 2 11 2 3

1 2 3

123

L1 L2 L3

L4 L5 L6

Covers

Covers prevent personnel, screws and foreign items fromcontacting live terminals. Available in white or clearplastic. Two cover clips supplied with each cover. Coverwidth is 1.31 inches.

All covers must be ordered separately. Consult factory forspecial legends.

Example: 10 position cover, white, TB100 Series, nolegends . . . Part # is X12010.

formation

Part Numbering System

Series Cover Strip Poles

■■■■ ■■■■■■■■■■■■ ■■■■■■■■120 - TB100/white 02 to 36 (TB100)119 - TB100/clear 02 to 30 (TB200/TB200HB)220 - TB200 & TB200HB* - white 02 to 24 (TB300/TB345)219 - TB200 & TB200HB* - clear320 - TB300 & TB345 - white319 - TB300 & TB345 - clear

X

Cover Clips – Bulk

Part NumberDD1 – TB100 SeriesDD2 – TB200 SeriesDD2HB – TB200HB SeriesDD3 – TB300 Series

Note: Not available on TB400 Series.* For use on TB200HB, specify HB after Part No. i.e., X21902HB

22 Fax ~ 314.527.1450

BIF document: 1426

Page 24: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

Double Row Terminal Blocks

Top Marker Strips

Top mounting marker strips are available in white(opaque) plastic. Two cover clips are supplied with eachmarker strip.

All top marker strips must be ordered separately. Consultfactory for special legends.

Example: 12 position cover, TB200, .032” x .312”, withno legends . . . Part # is X20312.

Example: 12 position cover, TB200HB, .060” x .500”,with no legends . . . Part # is X23312HB.

Part Numbering System

Series Top Marker Strip Poles

■■■■ ■■■■■■■■■■■■ ■■■■■■■■133 - TB100 (.060 thk x .500w) 02 to 36 (TB100) Note: Not available on TB400 Series.103 - TB100 (.032 thk x .312w) 02 to 30 (TB200/TB200HB)* * For use on TB200HB, specify HB 233 - TB200 & TB200HB* (.060 thk x .500w) 02 to 24 (TB300/TB345) after Part No. i.e., X23302HB203 - TB200 & TB200HB* (.032 thk x .312w)333 - TB300 & TB345 (.060 thk x .500w)303 - TB300 & TB345 (.032 thk x .380w)

X

Top & Bottom Marking Strips

BIF document: 1427

Bottom Marker Strips

Bottom mounting marker strips are made of black PVC,.030” thick. Space is available to handle most markingsituations. All marker strips must be ordered separately.

To order, specify part number, required legends and (BF)bottom forward, (BR) bottom reverse, (TF) top forward, or(TR) top reverse. Consult factory for specials.

Example: 13 position strip, TB100 with no legends, spacefor marking one side . . . Part # is X10513.

Position for legends (one side, two sides) can be speci-fied standard. Standard legend height is .125”. Standardlegends are 0-99. Special legends are available on spe-cial order. Drawing(s) must be submitted to ensure accu-racy of part required.

Part Numbering System

Series Bottom Marker Strip Poles Orientation

■■■■ ■■■■■■■■■■■■ ■■■■■■■■ ■■■■■■■■105 - TB100 – marking one side 02 to 36 (TB100) BF – bottom forward101 - TB100 – marking both sides 02 to 30 (TB200/TB200HB) BR – bottom reverse205 - TB200 – marking one side 02 to 24 (TB300/TB345) TF – top forward201 - TB200 – marking both sides TR – top reverse295 - TB200HB – marking one side291 - TB200HB – marking both sides305 - TB300 & TB345 – marking one side301 - TB300 & TB345 – marking both sides Note: Not available on TB400 Series.

X

Space for markingone side

Space for markingtwo sides

23 For complete specification data, call Bussmann Information Fax ~ 314.527.1450

Page 25: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

GET CONNECTED WITH US

Inches (Millimeters)

Power BlocksSeries 11675 & 11725

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

Series 11675SPECIFICATIONSRatings: 40A, 250V; UL/CSAPoles: 2 to 6 poles with (3) .250” quick-connect terminals per pole.Input wire sizes: #8 – #14 CUTorque rating: 18 in/lb max.Operating temperature: 150°CDesign: Screw connections for field wiring. Quick connects reduce cost of internal wiring.Agency approvals: UL E62622; CSA LR15364;

CE Pending

Quick-Connect Power Distribution Blocks

11675-4

For complete specification data, call Bussmann Informatio

.43(10.92)

1.03(26.16)

.37(9.39)

.20 (5.08) I.D.eyelets

.20 (5.08)dia. holes

.50(12.70)

1.37(34.79)

.20(5.08)

.56(14.22)

.76(19.30)

.46(11.68)

A

B

C

D

PartNumber A B C D

11675-2 2.09 1.68 .56 1.1511675-3 2.66 2.25 1.12 1.7111675-4 3.22 2.81 1.68 2.2811675-5 3.78 3.37 2.25 2.8411675-6 4.34 3.93 2.81 3.40

Series 11725SPECIFICATIONSRatings: 70A, 600V; UL/CSAPoles: 2, 3 or 4 poles with (4) .250” quick-connect terminals per pole.Input wire sizes: #2 – #14 CU/#8 ALTorque rating: 45 in/lb max.Operating temperature: 150°CDesign: Screw connections for field wiring. Quickconnects reduce cost of internal wiring.Agency approvals: UL E62622; CSA LR15364;

CE Pending

11725-2

BIF document: 1428

.43(10.92)

1.12(28.44)

.59(14.98)

.19 (4.98) I.D.eyelets

.19 (4.98)dia. holes

.62(15.74)

1.84(46.73)

.21(5.33)

.68(17.27)

.90(22.86)

.56(14.22)

A

B

C

D

PartNumber A B C D

11725-2 2.50 2.06 .68 1.3711725-3 3.18 2.75 1.37 2.0611725-4 3.87 3.43 2.06 2.75

24n Fax ~ 314.527.1450

Page 26: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

Barrier & Dead Front Terminal BlocksSeries 14002 & 14004

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

Series 14002SPECIFICATIONSRatings: 115A, 600V; UL/CSAPoles: 2 to 6 polesWire sizes: #2 – #14 CU/#8 ALOperating temperature: 150°CMarking: Marking strip optional, consult factory.Options: CP = Pressure plate, rated 60A, 600V

Q = Quick-Connect, rated 50A, 600VTo order options, enter letter code in front of Part No.: ie; CP14002-2Agency approvals: UL E62622; CSA LR15364;

CE Pending

Barrier Terminal Blocks

14002-2

25 For complete specification data

Inches (Millimeters)

.37(9.39)

1.25(31.75)

.17 (4.31) dia. holeswith .34 (8.63) dia. x.75 (19.05) deep c'bore

.75(19.05)

1.50(38.10)

.87(22.09)

.39(9.90)

.96(24.38)

.62(15.74)

A

B

A*

PartNumber A B

14002-2 1.75 –14002-3 2.37 –14002-4 3.34 1.5914002-5 3.96 2.2114002-6 4.59 2.84

Note: “A” dimension for 14002-2 & 14002-3 only.(14002-2 & 14002-3 have only two mounting holes.)

BIF document: 1429

Series 14004SPECIFICATIONSRatings: 90A, 600V; UL/CSAPoles: 2 to 12 polesWire sizes: #4 – #14 CU/#8ALOperating temperature: 75°CMarking: Marking strip optional, consult factory.Agency approvals: UL E62622; CSA LR15364

Dead Front Terminal Blocks

14004-4

Inches (Millimeters)

1.12(28.44)

.21 (5.33)dia. holes

.75(19.05)

1.50(38.10)

.65(16.51)

.18(4.57)

.50(12.70)

.50(12.70)

A

B

PartNumber A B

14004-2 1.81 1.4314004-3 2.31 1.9314004-4 2.81 2.4314004-5 3.31 2.9314004-6 3.81 3.4314004-7 4.31 3.9314004-8 4.81 4.9314004-9 5.31 4.9314004-10 5.81 5.4314004-11 6.31 5.9314004-12 6.81 6.43

, call Bussmann Information Fax ~ 314.527.1450

Page 27: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

GET CONNECTED WITH US

Inches (Millimeters)

Power Blocks

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

ConnectorPart Line Load Material & Agency

Number Connection Connection Ampacity Approvals

*16000 2/0-#8CU-AL 2/0-#8 CU-AL AL-175A UL –*16003 250MCM-#6CU 250MCM-#6CU CU-255A UL –*16005 350MCM-#6CU-AL 350MCM-#6CU-AL AL-310A UL –

16200 #2-#14CU/#8AL #2-#14CU/#8AL AL-115A UL CSA16201 1/0-#14CU 1/0-#14CU CU-150A UL CSA16204 2/0-#8CU-AL 2/0-#8CU-AL AL-175A UL CSA16301 250MCM-#6CU 250MCM-#6CU CU-255A UL CSA16303 350MCM-#6CU-AL 350MCM-#6CU-AL AL-310A UL CSA16306 500MCM-#6CU-AL 500MCM-#6CU-AL AL-380A UL CSA16500 (2)350MCM-#4CU-AL (2)350MCM-#4CU-AL AL-620A UL CSA16504 (2)500MCM-#6CU-AL (2)500MCM-#6CU-AL AL-760A UL CSA

Series 160, 162, 163 & 165

SPECIFICATIONSRatings: To 620A, 600V; UL/CSA. See table.Materials: Molded material: Black, UL rated 94V-0 thermoplasticOperating Temperature: 150°CMarking: Marker strip is optional, consult factory.Agency approvals: UL E62622 General Industrial Class per UL1059; CSA LR15364; CE Pending

Splicer Terminal Blocks

* 160 Series Bases have mounting holes outside the barriers. Other bases(162 through 165) have mounting holes within barriers. See dimensionaldrawings.

No. of Poles A B

2 4.12 3.623 5.37 4.874 6.62 6.12

2.00(50.80)

.50(12.70)

.68(17.27)

1.37(33.02)

2.06(52.32)

2.75(69.85)

.21 x .37 slots

B.26 dia.holes

.37(9.39)

1.00(25.40)

A

Series 160 (2, 3, & 4-pole available)

For complete specification data, call Bussmann Information

A

B

C

E

F

E

G HD

JMTG. HOLES .21 x .41C'BORE .42 x .62 x. 12 DEEP

Series 163 (1, 2, & 3-pole available)

Series 162 & 165 (1, 2, & 3-pole available)

Series A B C C C1-pole 2-pole 3-pole

162 2.87 2.25 1.06 1.87 2.68163 4.00 3.37 1.96 3.58 5.20165 5.50 4.75 3.12 5.81 8.50

Series D E F G H J

162 1.75 .81 .53 .31 .84 .31163 3.32 1.62 .97 .31 .87 .35165 3.12 2.68 1.56 .37 1.37 .62

BIF document: 1430

A

B

CE

F

E

G

D

H

J.20 dia. hole w/ .40 dia. c'bore

26 Fax ~ 314.527.1450

Page 28: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

Inches (Millimeters)

Power Blocks

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

Series 160, 162, 163 & 165

SPECIFICATIONSRatings: To 840A, 600V; UL/CSA. See table.Materials: Molded material: Black, UL rated 94V-0 thermoplasticOperating Temperature: 150°CMarking: Marker strip is optional; consult factory.Agency approvals: UL E62622 General Industrial Class per UL 1059; CSA LR15364; CE Pending

Power Distribution Blocks

ConnectorPart Line Load Material & Agency

Number Connection Connection Ampacity Approvals

*16021 2/0-#14CU/#8AL (6)#4-#14CU/#8AL AL-175A UL CSA*16023 350MCM-#6CU-AL (6)#4-#14CU/#8AL AL-310A UL CSA

16220 2/0-#14CU/#8AL (4)#4-#14CU/#8AL AL-175A UL CSA16321 2/0-#14CU-AL (6)#4-#14CU/#8AL AL-175A UL CSA16323 350MCM-#6CU-AL (6)#4-#14CU/#8AL AL-310A UL CSA16325 (2)2/0-#14CU/#8 AL (6)#4-#14CU/#8AL AL-350A UL CSA16330 500MCM-#6CU-AL (6)#2-#14CU/#8AL AL-380A UL CSA16332 350MCM-#6CU-AL (3)#2-#14CU/#8AL AL-310A UL CSA

& (2)1/0-#14CU/#8AL16335 500MCM-#6CU-AL (3)#2-#14CU/#8AL AL-380A UL CSA

& (2)1/0-#14CU/#8AL UL –16370 350MCM-#6CU-AL (12)#4-#14CU/#8AL AL-310A UL CSA16371 350MCM-#6CU-AL (6)#2-#14CU/#8AL AL-310A UL CSA

(3)1/0-#14CU/#8AL16372 350MCM-#6CU-AL (21)#10-#14CU/#10AL AL-310A UL CSA16373 350MCM-#6CU-AL (3)1/0-#14CU/#8AL AL-310A UL CSA

(14)#10-#14CU/#8AL16375 600MCM-#2CU-AL (12)#4-#14CU/#8AL AL-420A UL CSA16376 600MCM-#2CU-AL (6)#2-#14CU/#8AL AL-420A UL CSA

(3)1/0-#14CU-8AL16377 (2)300MCM-#2CU-AL (12)#4-#14CU/#8AL AL-570A UL –16528 (2)600MCM-#2CU-AL (4)3/0-#8CU-AL AL-840A UL CSA

& (4)#4-#14CU/#8AL16530 (2)500MCM-#6CU-AL (12)#4-#14CU/#8AL AL-760A UL CSA

* 160 Series Bases have mounting holes outside the barriers. Other bases(162 through 165) have mounting holes within barriers. See dimensionaldrawings.

27 For complete specification data

C

D

E

F

E

A

B G

JMTG. HOLES .21 x .41

C'BORE .42 x .62 x. 12 DEEP

Series 163 (1, 2, & 3-pole available)

BIF document: 1431

2.00(50.80)

.37(9.39)

1.00(25.40)

.50(12.70)

.68(17.27)

1.37(33.02)

2.06(52.32)

2.75(69.85)

.21 x .37 slots

B

A

.26 dia.holes

Series 160 (2, 3, & 4-pole available)

No. of Poles A B

2 4.12 3.623 5.37 4.874 6.62 6.12

20. dia. hole w/ .40 dia. c'bore

A DHBG

J

F

C

E

E

Series 162 & 165 (1, 2, & 3-pole available)

Series A B C C C1-pole 2-pole 3-pole

162 2.87 2.25 1.06 1.87 2.68163 4.00 3.37 1.96 3.58 5.20165 5.50 4.75 3.12 5.81 8.50

Series D E F G H J

162 1.75 .81 .53 .31 .84 .31163 3.32 1.62 .97 .31 .87 .35165 3.12 2.68 1.56 .37 1.37 .62

, call Bussmann Information Fax ~ 314.527.1450

Page 29: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

GET CONNECTED WITH US

Connector/Stud Power Distribution Blocks Inches (Millimeters)

Power Blocks

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

Series 162, 163 & 165

SPECIFICATIONSRatings: To 760A, 600V; UL/CSA. See table.Materials: Molded material: Black, UL rated 94V-0 thermoplasticOperating Temperature: 150°CAgency approvals: UL E62622 General Industrial Class per UL 1059. CSA LR15364; CE Pending.

ConnectorPart Line Load Material & Agency

Number Connection Connection Ampacity ApprovalsConnector to Stud

16280 2/0-#14CU/#8AL 1/4-20x1/2 Stud AL-175A UL CSA16281 2/0-#14CU/#8AL 1/4-20 Tapped hole AL-175A UL CSA16378 500MCM-#6CU-AL (2)1/4-20x1 Stud AL-380A UL CSA16383 500MCM-#6CU-AL (1)3/8-16x11/4 Stud AL-380A UL CSA16582 (2)500MCM-#6CU-AL (2)3/8-16x15/8 Stud AL-760A UL CSA

Stud to Stud16390 3/8-16x11/8 Stud 3/8-16x11/8 Stud CU-250A UL CSA16394 1/2-13x11/16 Stud 1/2-13x11/16 Stud CU-400A UL CSA16395 3/8-16x17/16 Stud (2)1/4-20x9/16 Stud CU-310A UL CSA16591 3/8-16x17/16 Stud (2)3/8-16x17/16 Stud CU-400A UL –16593 1/2-13x1 Stud 1/2-13x1 Stud CU-600A UL CSA

BUSSCPDB

®

TEXTUREDSURFACE

SUPPLIED WITH(4) #4 THREAD-CUTTING SCREWS

ASSEMBLED AS SHOWN

CPDB-1=2.10"CPDB-2=3.72"CPDB-3=5.34"

4.14

New Option Available on163 Series Power BlocksPROTECTIVE COVER TO GUARDAGAINST ACCIDENTAL CONTACT• Clear with write on surface for field

termination identification.• Available in 1, 2, & 3 poles.

For complete specification data, call Bussmann Informati

A

B

CE

F

E

G

D

H

J.20 dia. hole w/ .40 dia. c'bore

Series 163 (1, 2, & 3-pole available)

BIF document: 1432

Series A B C C C1-pole 2-pole 3-pole

162 2.87 2.25 1.06 1.87 2.68163 4.00 3.37 1.96 3.58 5.20165 5.50 4.75 3.12 5.81 8.50

Series D E F G H J

162 1.75 .81 .53 .31 .84 .31163 3.32 1.62 .97 .31 .87 .35165 3.12 2.68 1.56 .37 1.37 .62

A

B

J

H

C

E

F

E

G

D

MTG. HOLES .21 x .41C'BORE .42 x .62 x. 12 DEEP

Series 162 & 165 (1, 2, & 3-pole available)

28on Fax ~ 314.527.1450

Page 30: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

Inches (Millimeters)

Power BlocksSeries EN

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

SPECIFICATIONSRatings: 285A, 600V; UL/CSALine connector: #300MCM-#6 CU/ALLoad connection: (6)#6-#14 CU/#8 ALMaterial: Molded material; Black, UL rated 94V-2 thermoplasticOperating temperature: 125°CAgency approvals: UL E62622; CSA LR15364;

CE Pending

Series EN 1.78” Centers

Series A B

EN61 1.38 1.78EN62 3.15 3.62EN63 4.93 5.37

29 For complete specification da

BIF document: 1433

.20 x .37mtg. slot

1.68(42.67)

.50(12.70)

2.12(53.84)

A

B

ta, call Bussmann Information Fax ~ 314.527.1450

Page 31: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

GET CONNECTED WITH US

Wire Management Products

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

Photo Control Receptacle Series

■ 3-pole, 3-wire receptacles for plug-in, locking type photo controls used in outdoor areas and roadway lighting.

■ Receptacle configuration, terminals and limiting dimensionsare in accordance with Figure 3 of EE Pub. No. TDJ-146,NEMA Pub. No. SH 16-1962 and UL 773.

■ Wire types and sizes ranging from #12 AWG through 16 AWGrated at 600V with temperature ratings from 105° to 200°C.

■ Hook-up wires are an integral part of the assembly withlengths furnsihed to customer specification.

■ Available with .250 quick-connect terminals in lieu of wireleads (13661-Q).

■ UL recognized under file E65288 for a rating of 1 KW or1800VA for potentials up to 480V.

■ CSA certified under file LR21295 for 15 amps at 125V.■ CE Pending.

BLACK (B)

WHITE (COM)

"Z" (WIRE LENGTH IN INCHES)

RED (R)

A

A

.14 DIA. W/.28 DIA. x 80°C'SINK (2 HOLES)

2.56

.96

1.93 1.37

1.45

1.37

MODEL 13661

For complete specification data, call Bussmann Information Fax ~ 314.527

1.56

.62

1.37 DIA.1.37

MODEL 13661-Q

Part Numbering System

Terminal Wire Wire WireSeries Type Type Gauge Length

■■■■■■■■■■■■■■■■■■■■ - ■■■■ ■■■■ ■■■■ ■■■■W = Wire See Table See Table DimensionQ = Quick Connect “Z”

1 3 6 6 1

TABLE I (WIRE TYPE)ASS’Y NO. WIRE DESCRIPTION13661-W1XX Min. of 26 Strands, Copper Conductor, 125ºC-600V Crosslinked Polyethylene.

13661-W2XX Min. of 26 Strands, Copper Conductor, Silicone Rubber Insulation And FiberGlass Braid Jacket, Nec. Type SFF-2(150ºC)

13661-W3XX Min. Of 26 Strands, Copper Conductor, Type TW, 105ºC-600V Insulation(16 gauge only).

13661-W4XX Min. of 7 Strands, Copper Conductor Of .0192 Silicone Rubber Insulation AndFiber Glass Braid Jacket, Nec. Type SF-2 (200ºC)

13661-W5XX Min. Of 19 Strands, Copper Conductor, Type AWM. 105ºC-600V Insulation.

TABLE II (WIRE GAUGE)ASS’Y NO. GAUGE

13661-WX2X 12 Gauge13661-WX4X 14 Gauge13661-WX6X 16 Gauge

BIF document: 1434

30.1450

Page 32: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

Disconnect Blocks

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com

Nonfused, Disconnects

■ Ratings: 60A, 240V■ Wire Range: #2-14 CU/#8 AL■ Available in both 2 and 3 pole versions for both single and three phase systems.■ Compact, one-piece thermoplastic housing is rated to 150°C.■ Box connector or quick-connect terminations available on load side. Box

connector standard on line side.■ Body of disconnect can be mounted enabling disconnect head (pull-out) to

interlock with door to insure power is off when door is open.■ UL E120756; CSA LR 37129; CE Pending.

Part Numbering System

Line Side Load SideSeries Poles Connections Connections Options

■■■■■■■■■■■■■■■■■■■■■■■■■■■■ - ■■■■ ■■■■ ■■■■ ■■■■2 C = Box C = Box Connection H = Wire3 Connection Q = (4) .250" Quick- Handle

Connects

N D - 1 2 6 0

31 For complete specification data, call Bussmann Information Fax ~ 314.527.1450

LINE SIDE

LOAD SIDE

WIRE HANDLEOPTIONAL

WIRE HANDLEOPTIONAL

L0AD SIDE

2.50

1.25

.621.251.932.03

LINE SIDE

.06

2.25

2.96

.25

.54

.20.40

1.06 1.061.70

1.0312.06

.20 DIA. (2 HOLES) .20 DIA. (4 HOLES)1.673.34

.62

1.25

.40.20

1.70

.25.54

2.96

.06 .18

MALE DISCONNECTSHOWN INSTALLED

2.251.43

1.28

2.15

.12

1.00

3.283.18

1.25

2.503.62

.62

BIF document: 1435

Page 33: Contents 230 Ryan Way, South San Francisco, CA, 94080 · RAIL & BASE MOUNT TERMINAL BLOCKS PAGES General Specifications & Accessories for Rail Mount Terminal Blocks 3 NDN Series.250”

BUSSMANN CIRCUIT COMPONENTS • 7300 W. Wilson Ave. • Chicago, IL 60656-4708 • Fax: 800-832-9873 • Phone: 888-YES MAGNUMWebsite: http://www.busscc.com

An ISO 9001 Quality System Certified Facility

Look for other reliable productsin these comprehensive catalogs . . .

Circuit Protection

MAGNUM® Terminal Blocks

Products for the DC mobile and AC supplementary circuit protection

requirements including Shortstop®, Flat-Pak® and Hi-Amp™ auto, manual

or modified reset and switchable circuit protectors, Maxi™ ATC®, ATM®

blade type circuit protectors, Stud Type Junction Blocks, Small

Dimension Fuse Panels, Battery Disconnect Switches and Power

Distribution Modules.

A complete line of conventional terminal blocks in an easy-to-use

catalog. Includes Single Row, Double Row, Depluggable and Edge

Connectors, Interface Systems and accessories. Popular center

spacings include .250", .325", .375", .437", .562" and .687" with

the industry’s most comprehensive range of options.

MAGNUM®

GET CONNECTED WITH US

MAGNUM® Euro-Mag Terminal BlocksMAGNUM® has just expanded it’s product line to include European style

PCB terminal blocks. These blocks are available in sizes ranging from

3.81mm to 10.16mm centers. Configurations include single, two-tier,

depluggable and screwless. All blocks have full agency approvals and

are available in horizontal, vertical, and 45º wire orientations.

FORM NO. MEP1/15M/1097

C

ourte

sy o

f Ste

ven

Eng

inee

ring,

Inc.

� 2

30 R

yan

Way

, Sou

th S

an F

ranc

isco

, CA

, 940

80-6

370 �

Mai

n O

ffice

: (65

0) 5

88-9

200 �

Out

side

Loc

al A

rea:

(800

) 258

-920

0 �

ww

w.s

teve

neng

inee

ring.

com