(3) Counter
T he counter v alues can be display ed.
F unction P urpose Setting D etails/P recautions
T O T A L C O U NT E R
T o display the total number of
pages used.
C O P Y : Number of copies
printed
P R INT : Number of computer
printouts printed
T est prints made in Serv ice
mode to check the operation
are not counted.
P M C O U NT E R
T o display the number of times that
P M parts are used.
T o clear the counter data, use
the functions on the C L E A R
D A T A menu of Serv ice
mode.
S-73
I/C C O U NT E R
T o display the total number of
times that the D rum C artridge has
been used.
T o clear the counter data, use
the functions on the C L E A R
D A T A menu of Serv ice
mode.
S-73
A P P L IC A T IO N
C O U NT E R
T o display the number of pages
used w ith each application.
C O P Y P R INT : Number of cop-
ies printed
F A X R X P R INT : (Not U sed)
R E P O R T P R INT : (Not U sed)
P C P R INT : Number of com-
puter printouts printed
F A X T X P A G E : (Not U sed)
M A IL T X P A G E : (Not U sed)
T o clear the counter data, use
the functions on the C L E A R
D A T A menu of Serv ice
mode.
S-73
SC A N C O U NT E R
T o display the number of scans
made.
M O NO C H R O M E : Number of
monochrome scans
C O L O R : Number of color scans
Scans made w hile mak ing
copies are not counted.
T o clear the counter data, use
the functions on the C L E A R
D A T A menu of Serv ice
mode.
S-73
-
S-69
NOTES
The following counters continue counting even while op era tions a re p erform ed in S ervice
m od e.
P M CO UNTER
IC CO UNTER
P RINTER J A M CO UNTER
A DF J A M CO UNTER
TRO UB L E CO UNTER
S-73
PRINTER J AM
COUNTER
To display the number of misfeeds
that occurred while printing.
To clear the counter data, use
the functions on the CLEAR
DATA menu of Service
mode.
S-73
ADF J AM
COUNTER
To display the number of misfeeds
that occurred while using the Auto-
matic Document Feeder.
To clear the counter data, use
the functions on the CLEAR
DATA menu of Service
mode.
S-73
TROUB LE
COUNTER
To display the number of times
each error was detected.
C004 5:Fuser fan error
C021 0:Transfer voltage error
C0500:Fuser W arm up error
C051 0:Fuser temperature low
C0520:Fuser overheat
C0650:Home sensor error /
Scanner motor error
C1 200:ASIC memory abnormal
C1 300:Polygon mirror motor
error
C1 33B :Communication with
option error
C1 33C:Modem error
C1 33D:ROM checksum error
C1 3F0:Laser error
C1 4 68:EEPROM error
C1 4 A3:IR lamp malfunction
To clear the counter data, use
the functions on the CLEAR
DATA menu of Service
mode.
S-73
Function Purpose Setting Details/Precautions