CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8% air entrainment Reinforcement : Steel to CSA CAN A23.1 Weight-18,000lbs / 8,180kg Drawn by: O.B Date: Feb/2011 armtec concrete brooklin BCP 104S Foundation for 3 Phase Padmount Transformer. Typical Use: Mississauga HM-10-101 (up to 1000KVA/1200A) Front view scale:1:50 Top view scale:1:50 Delivery is made by crane-equipped trucks, excavation must be ready, safe and accessible for unloading from the rear of the truck. Min overhead clearance of 18ft is required. ALL UNITS MUST BE HANDLED WITH PROPER LIFTING EQUIPMENT. (I.E. SPREADER BAR) Cable entry openings-PVC seals for max 4"I.D. duct 2286 [90"] 2083 [82"] 2692 [106"] 12" Sump pit 4" Drain Knockout 152 [6"] 152 [6"] 1143 [45"] 2286 [90"] 152 [6"] 152 [6"] Right view scale:1:50 2159 [85"] 2769 [109"] 1270 [50"] 762 [30"] 711 [28"] 1118 [44"] 127 [5"] 203 [8"] 203 [8"] 320 [12 5/8"] 28"x44" Galvanized Door w/ lock bar 203 [8"] 203 [8"] 320 [12 5/8"] Galvanized Lock Bar Padlock Eyehole 445 [17 1/2"] 521 [20 1/2"]

Upload: doantuyen

Post on 01-Feb-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight-18,000lbs / 8,180kg

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklinBCP 104S

Foundation for 3 Phase Padmount Transformer.

Typical Use: Mississauga HM-10-101 (up to 1000KVA/1200A)

Front view

scale:1:50

Top view

scale:1:50

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

Cable entry openings-PVC seals for max

4"I.D. duct

22

86

[9

0"]

2083

[82"]

2692

[106"]

12" Sump pit

4" Drain

Knockout

15

2

[6

"]

15

2

[6

"]

11

43

[4

5"]

22

86

[9

0"]

15

2

[6

"]

15

2

[6

"]

Right view

scale:1:50

21

59

[8

5"]

2769

[109"]

12

70

[5

0"]

762

[30"]

711

[28"]

11

18

[4

4"]

127

[5"]

203

[8"]

20

3

[8

"]

32

0

[1

2 5

/8

"]

28"x44"

Galvanized Door

w/ lock bar

203

[8"]

20

3

[8

"]

32

0

[1

2 5

/8

"]

Galvanized

Lock Bar

Padlock

Eyehole

44

5

[1

7 1

/2

"]

52

1

[2

0 1

/2

"]

Page 2: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight - 9,750lbs / 4,430kg

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklinBCP 113S

Foundation for 3 Phase Padmount Transformer.

Typical Use: Mississauga HM-10-102

(Up to 500kVA or 600)

Front view

scale:1:50

Top view

scale:1:50

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

Cable entry openings-PVC seals for max

4"I.D. duct

4" Drain

Knockout

12" Sump pit

4" Drain

Knockout

12" Sump pit

Right view

scale:1:50

16

32

[6

4 1

/2

"]

2546

[100"]

762

[30"]

12

70

[5

0"]

190

[7 1/2"]

2464

[97"]

91

4

[3

6"]

18

28

[7

2"]

1549

[61"]1

52

[6

"]

89

[3 1/2"]

91

4

[3

6"]

18

28

[7

2"]

15

2

[6

"]

89

[3 1/2"]

127

[5"]

711

[28"]

11

18

[4

4"]

28"x44"

Galvanized Door

w/ lock bar

20

3

[8

"]

165

[6 1/2"]

406

[16"]

20

3

[8

"]

11

4

[4

1

/2

"]

11

4

[4

1

/2

"]

Galvanized

Lock Bar

Padlock

Eyehole

1" grounding hole

Page 3: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight-10,300lbs / 4,680kg

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklinBCP 113MH

Precast Concrete Manhole Structure.

Typical Use: Boulevard

Front view

scale:1:50

Top view

scale:1:50

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

Typical use would include a standard

manhole frame & cover (OPSD 401.01) for

burial depth add at least 6".

Cable entry openings-PVC seals for max

4"I.D. duct

4" Drain

Knockout

12" Sump pit

4" Drain

Knockout

12" Sump pit

Right view

scale:1:50

16

32

[6

4 1

/2

"]

2546

[100"]

2464

[97"]

91

4

[3

6"]

18

28

[7

2"]

22

8

[9

"]

80

0

[3

1 1

/2

"]

165

[6 1/2"]

1549

[61"]1

52

[6

"]

89

[3 1/2"]

91

4

[3

6"]

18

28

[7

2"]

20

3

[8

"]

22

8

[9

"]

15

2

[6

"]

89

[3 1/2"]

26" Opening

Page 4: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight-10,300lbs / 4,680kg

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklinBCP 113

Foundation for 3 Phase Padmount Transformer.

Typical Use: Newmarket

Front view

scale:1:50

Top view

scale:1:50

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

Cable entry openings-PVC seals for max

4"I.D. duct

4" Drain

Knockout

12" Sump pit

4" Drain

Knockout

12" Sump pit

Right view

scale:1:50

16

32

[6

4 1

/2

"]

2546

[100"]

762

[30"]

91

4

[3

6"]

305

[12"]

2464

[97"]

91

4

[3

6"]

18

28

[7

2"]

22

8

[9

"]

80

0

[3

1 1

/2

"]

165

[6 1/2"]

1549

[61"]1

52

[6

"]

89

[3 1/2"]

91

4

[3

6"]

18

28

[7

2"]

20

3

[8

"]

22

8

[9

"]

15

2

[6

"]

89

[3 1/2"]

Page 5: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

Left view

scale:1:40

Front view

scale:1::40

Top view

scale:1:40

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight-3625lbs / 1590kg

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklin

1931

[76"]

15

76

[6

2"]

102

[4"]

1727

[68"]

102

[4"]

10

67

[4

2"]

20

3

[8

"]

20

3

[8

"]

203

[8"]

1931

[76"]

102

[4"]

1372

[54"]

102

[4"]

10

67

[4

2"]

20

3

[8

"]

1576

[62"]

203

[8"]

33

0

[1

3"]

483

[19"]

BCP 111P

FOUNDATION FOR PADMOUNT

TRANSFORMER / SWITCHGEAR

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

47

0

[1

8 1

/2

"]

2" Lifting points

2-1/2"

Lifting

point

Cable entry openings-PVC seals for max

4"I.D. duct

Page 6: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

Left view

scale:1:40

Front view

scale:1::40

Top view

scale:1:40

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight-3625lbs / 1590kg

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklin

1931

[76"]

15

76

[6

2"]

102

[4"]

1727

[68"]

102

[4"]

10

67

[4

2"]

30

5

[1

2"]

457

[18"]

1931

[76"]

102

[4"]

1372

[54"]

102

[4"]

10

67

[4

2"]

30

5

[1

2"]

1576

[62"]

457

[18"]

33

0

[1

3"]

483

[19"]

BCP 111

FOUNDATION FOR PADMOUNT

TRANSFORMER / SWITCHGEAR

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

47

0

[1

8 1

/2

"]

2" Lifting points

2-1/2"

Lifting

point

737

[29"]

737

[29"]

560

[22"]

560

[22"]

Page 7: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

Right view

scale:1:30

Front view

scale:1:30

Top view

scale:1:30

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight-3,560lbs / 1540kg

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklinBCP 110PM

Precast Foundation For Padmount Transformer.

Typical Use: Single Phase Powerstream # 1701000, Mississagua

HM11290, Brampton 37-113

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

Cable entry openings-PVC seals for max

4"I.D. duct

1

2

" N.C. Threaded

Inserts

25

4

[1

0"]

152

[6"]

20

3

[8

"]

712

[28"]

165

[6 1/2"]

Recessed

Lift Point/

Pulling eye

17

8

[7

"]

1016

[40"]

12

19

[4

8"]

406

[16"]

864

[34"]

203

[8"]

38

1

[1

5"]

16

5

[6

1

/2

"]

16

5

[6

1

/2

"]

165

[6 1/2"]

12

19

[4

8"]

1473

[58"]

1016

[40"]

14

73

[5

8"]

86

4

[3

4"]

712

[28"]

43

2

[1

7"]

2" Grounding

Holes

Page 8: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

Right view

scale:1:30

Front view

scale:1:30

Top view

scale:1:30

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight-3,560lbs / 1540kg

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklinBCP 110PC

Precast Foundation For Padmount Transformer.

Typical Use: Single Phase less than 167kVA

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

Cable entry openings-PVC seals for max

4"I.D. duct

1

2

" N.C. Threaded

Inserts

14

73

[5

8"]

1016

[40"]

10

67

[4

2"]

152

[6"]

20

3

[8

"]

10

2

[4

"]

17

8

[7

"]

88

9

[3

5"]

25

4

[1

0"]

12

7

[5

"]

25

4

[1

0"]

20

3

[8

"]

165

[6 1/2"]

2" Lifting

hole.

712

[28"]

86

4

[3

4"]

1016

[40"]

165

[6 1/2"]

203

[8"]

864

[34"]

406

[16"]

1473

[58"]

10

67

[4

2"]

43

2

[1

7"]

114

[4 1/2"]

Page 9: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

Right view

scale:1:30

Front view

scale:1:30

Top view

scale:1:30

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight-5,500lbs / 2500kg

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklinBCP 110H20

Precast Manhole. This vault is designed to resist Ontario Highway

Design wheel loads as follow:

Individual wheel 100kN (22,300lbs)/ Dual axle 2-70kN (spaced @ 1.2m)

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

Cable entry openings-PVC seals for max

4"I.D. duct

26" opening.

BCP 110T6H20

14

73

[5

8"]

1016

[40"]

BCP 110PC

BCP 110B

10

67

[4

2"]

15

2

[6

"]

15

2

[6

"]

1016

[40"]

152

[6"]

152

[6"]

165

[6 1/2"]

20

3

[8

"]

10

2

[4

"]

17

8

[7

"]

88

9

[3

5"]

25

4

[1

0"]

12

7

[5

"]

15

2

[6

"]

13

71

[5

4"]

1473

[58"]

25

4

[1

0"]

20

3

[8

"]

165

[6 1/2"]

2" Lifting

hole.

BCP 110T6H20

BCP 110PC

BCP 110B

Page 10: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

Right view

scale:1:30

Front view

scale:1:30

Top view

scale:1:30

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight-3,400lbs / 1,545kg

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklinBCP 110C

Precast Foundation For Padmount Transformer .

Typical Use: Single Phase less than 167 kVA

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

1

2

" N.C. Threaded

Inserts

14

73

[5

8"]

1016

[40"]

10

67

[4

2"]

152

[6"]

165

[6 1/2"]

17

8

[7

"]

88

9

[3

5"]

25

4

[1

0"]

12

7

[5

"]

2" Lifting

hole.

1016

[40"]

457

[18"]

152

[6"]

30

5

[1

2"]

30

5

[1

2"]

1473

[58"]

406

[16"]

203

[8"]

407

[16"]

660

[26"]

152

[6"]

864

[34"]

712

[28"]

86

4

[3

4"]

Page 11: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

Right view

scale:1:20

Front view

scale:1:20

Top view

scale:1:30

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight-1,200lbs / 545kg

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklinBCP 110B

Precast Base For Padmount

Transformer Foundation BCP 110 Series

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

4" Drain

Knockout

14

73

[5

8"]

1016

[40"]

1016

[40"]

15

2

[6

"]

203

[8"]

203

[8"]

20

3

[8

"]

203

[8"]

4" Drain

Knockout

1473

[58"]

15

2

[6

"]

203

[8"]

203

[8"]

4" Drain

Knockout

1

2

" N.C threaded

Inserts

1

2

" N.C threaded

Inserts

305

[12"]

305

[12"]

2" Lifting Holes

Page 12: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklin

Right View

Scale 1:50

Top View

Scale 1:25

Front View

Scale 1:50

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

BCP 109

Precast Concrete Foundation for Padmount Transformer

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight-2,900lbs / 1,320kg

2" Lifting

Holes

1245

[49"]

96

5

[3

8"]

941

[37"]

66

1

[2

6"]

941

[37"]

152

[6"]

152

[6"]

33

0

[1

3"]

10

67

[4

2"]

533

[21"]

152

[6"]

152

[6"]

432

[17"]

33

0

[1

3"]

965

[38"]

152

[6"]

152

[6"]

10

67

[4

2"]

Page 13: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklin

Right View

Scale 1:50

Top View

Scale 1:50

Front View

Scale 1:50

5055

[199"]

25

91

[1

02

"]

10

8

[4

1

/4

"]

16

19

[6

3 3

/4

"]

32

38

[1

27

1

/2

"]

5055

[199"]

16

19

[6

3 3

/4

"]

32

38

[1

27

1

/2

"]

2591

[102"]

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

Cable entry openings-PVC seals for max

4"I.D. duct

28"x44"

Galvanized Door

w/ lock bar

BCP 106V

Precast Concrete Utility Foundation with galvanized Lockable

Frame & Cover.

35

5

[1

4"]

20

3

[8

"]

203

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight-43,285lbs / 19,635kg

16

19

[6

3 3

/4

"]

16

26

[6

4"]

306

[12"]

508

[20"]

253

[10"]

Page 14: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight-25,100lbs / 11,400kg

Drawn by: O.B Date: Jan/2011

armtecconcrete

brooklinBCP 104H20

Precast Utility Manhole. This vault is designed to resist Ontario Highway

Design wheel loads as follow:

Individual wheel 100kN (22,300lbs)/ Dual axle 2-70kN (spaced @ 1.2m)

Front view

scale:1:50

Top view

scale:1:50

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

Cable entry openings-PVC seals for max

4"I.D. duct

4" Drain

Knockout

22

35

[8

8"]

2845

[112"]

22

86

[9

0"]

2159

[85"]

2769

[109"]

12" Sump pit

4" Drain

Knockout

19

8

[7

3

/4

"]

19

8

[7

3

/4

"]

16

5

[6

1

/2

"]

16

5

[6

1

/2

"]

32"

opening

12" Sump pit

11

43

[4

5"]

22

86

[9

0"]

406

[16"]

19

8

[7

3

/4

"]

20

3

[8

"]

203

[8"]

16

5

[6

1

/2

"]

16

5

[6

1

/2

"]

165

[6 1/2"]

203

[8"]

20

3

[8

"]

Right view

scale:1:50

Page 15: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

Front view

scale:1:50

Top view

scale:1:50

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight-20,100lbs / 9,140kg

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklinBCP 104

Precast Concrete Utility Manhole

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

Cable entry openings-PVC seals for max

4"I.D. duct

Manhole opening

location and size may

be modified as required

12" Sump pit

4" Drain

Knockout

21

59

[8

5"]

2769

[109"]

Right view

scale:1:50

22

86

[9

0"]

2083

[82"]

2692

[106"]

11

43

[4

5"]

22

86

[9

0"]

27

1

[1

1"]

33

0

[1

3"]

165

[6"]

165

[6"]

12" Sump pit4" Drain

Knockout

16

5

[6

"]

16

5

[6

"]

27

1

[1

1"]

20

3

[8

"]

165

[6"]

15

2

[6

"]

15

2

[6

"]

127

[5"]

32"

opening

Page 16: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight - 9,750lbs / 4,430kg

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklinBCP 113SM

Foundation for 3 Phase Padmount Transformer.

Typical Use: Mississauga HM-10-102

(Up to 500kVA or 600)

Front view

scale:1:50

Top view

scale:1:50

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

Cable entry openings-PVC seals for max

4"I.D. duct

4" Drain

Knockout

12" Sump pit

4" Drain

Knockout

Cylindrically Straight

12" Sump pit

Right view

scale:1:50

16

32

[6

4 1

/2

"]

2546

[100"]

457

[18"]

12

70

[5

0"]

305

[12"]

2464

[97"]

91

4

[3

6"]

18

28

[7

2"]

1549

[61"]1

52

[6

"]

89

[3 1/2"]

91

4

[3

6"]

18

28

[7

2"]

15

2

[6

"]

89

[3 1/2"]

127

[5"]

711

[28"]

11

18

[4

4"]

28"x44"

Galvanized Door

w/ lock bar

20

3

[8

"]

165

[6 1/2"]

165

[6 1/2"]

20

3

[8

"]

11

4

[4

1

/2

"]

11

4

[4

1

/2

"]

Galvanized

Lock Bar

Padlock

Eyehole

1" grounding hole

Page 17: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

Top view

scale:1:30

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight (total)- 3,625lbs / 1,590kg

Weight (Indiv Lid)- 550lbs / 250kg

Drawn by: O.B Date: Mar/2011

armtecconcrete

brooklinBCP 112PC

Precast Concrete Pulling Chamber

Typical Use: Boulevard

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

Front view

scale:1:30

Right view

scale:1:30

2" Lifting

Holes

1829

[72"]

12

19

[4

8"]

18

4

[7

1

/4

"]

184

[7 1/4"]

476

[18 3/4"]

476

[18 3/4"]

184

[7 1/4"]

255

[10"]

102

[4"]

915

[36"]

915

[36"]

91

4

[3

6"]

10

2

[4

"]

1219

[48"]

18

4

[7

1

/4

"]

12

7

[5

"]

184

[7 1/4"]

102

[4"]

368

[14 1/2"]

368

[14 1/2"]

10

2

[4

"]

10

16

[4

0"]

BCP 112PCL

BCP112P

BCP 112PCL

Consist of three pieces:

1x BCP 112P

2x BCP 112PCL

Page 18: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

Top view

scale:1:40

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight - 1,260lbs / 572kg

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklinBCP 111TK (Kabar)

Precast Top for BCP 111 series

Typical Use: Ontario Hydro Kabar Switchgear

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

1

2

" N.C. Threaded

Inserts

1981

[78"]

16

26

[6

4"]

127

[5"]

12

7

[5

"]

1981

[78"]

15

2

[6

"]

Front view

scale:1:40

1626

[64"]

15

2

[6

"]

305

[12"]

305

[12"]

Right view

scale:1:40

1473

[58"]

11

18

[4

4"]

25

4

[1

0"]

2" Lifting

Holes

Page 19: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

Top view

scale:1:40

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight - 1,260lbs / 572kg

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklinBCP 111TGW

Precast Top for BCP 111 series

Typical Use: Ontario Hydro G&W / SF6 Switchgear

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

1

2

" N.C. Threaded

Inserts

1981

[78"]

16

26

[6

4"]

127

[5"]

12

7

[5

"]

1981

[78"]

15

2

[6

"]

Front view

scale:1:40

1626

[64"]

15

2

[6

"]

305

[12"]

305

[12"]

Right view

scale:1:40

1524

[60"]

66

0

[2

6"]

22

9

[9

"]

2" Lifting

Holes

305

[12"]

305

[12"]

Page 20: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

Top view

scale:1:40

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight - 2,200lbs / 1,000kg

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklinBCP 111T

Precast Top for BCP 111 series

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

1

2

" N.C. Threaded

Inserts

1981

[78"]

16

26

[6

4"]

305

[12"]

30

5

[1

2"]

1981

[78"]

15

2

[6

"]

Front view

scale:1:40

1626

[64"]

15

2

[6

"]

305

[12"]

305

[12"]

Right view

scale:1:40

1016

[40"]

45

7

[1

8"]

25

4

[1

0"]

483

[19"]

483

[19"]

2" Lifting

Holes

305

[12"]

305

[12"]

Page 21: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

Top view

scale:1:40

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight - 2,600lbs / 1,120kg

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklinBCP 111B

Precast Base for BCP 111 series

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

1

2

" N.C. Threaded

Inserts

1981

[78"]

16

26

[6

4"]

305

[12"]

30

5

[1

2"]

4" Drain

Knockout

1981

[78"]

15

2

[6

"]

Front view

scale:1:40

4" Drain

Knockout

1626

[64"]

15

2

[6

"]

4" Drain

Knockout

Right view

scale:1:40

305

[12"]

305

[12"]

2" Lifting

Hole

76

[3

"]

Page 22: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

Top view

scale:1:30

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI 6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight - 818lbs / 371kg

Drawn by: O.B Date: Mar/2011

armtecconcrete

brooklinBCP 110TCM

Precast Collar for Padmount Transformer

Typical Use: Mississauga Hydro Retrofit Collar

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

1

2

" N.C. Threaded

Inserts

Front view

scale:1:20

Right view

scale:1:20

1321

[52"]

11

94

[4

7"]

99

1

[3

9"]

1168

[46"]

254

[10"]

12

7

[5

"]

940

[37"]

68

6

[2

7"]

153

[6"]

1168

[46"]

22

9

[9

"]

279

[11"]

940

[37"]

102

[4"]

1321

[52"]

12

7

[5

"]

10

2

[4

"]

991

[39"]

102

[4"]

102

[4"]

254

[10"]

686

[27"]

254

[10"]

22

9

[9

"]

Page 23: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

THICKNESS

Top view

scale:1:30

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI 6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight(6") - 700lbs / 320kg

Weight(12") -1,400lbs / 640kg

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklinBCP 110TC

Precast Collar for Padmount Transformer

Typical Use: Grade Adjustment for 110 series

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

1

2

" N.C. Threaded

Inserts

737

[29"]

330

[13"]

71

1

[2

8"]

10

16

[4

0"]

76

[3

"]

279

[11"]

533

[21"]

737

[29"]

737

[29"]

102

[4"]

102

[4"]

737

[29"]

15

2

[6

"]

737

[29"]

737

[29"]

30

5

[1

2"]

102

[4"]

102

[4"]

711

[28"]

153

[6"]

153

[6"]

15

2

[6

"]

711

[28"]

153

[6"]

153

[6"]

30

5

[1

2"]

15

3

[6

"]

76

[3

"]

Page 24: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

Right view

scale:1:30

Front view

scale:1:30

Top view

scale:1:30

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight-3,560lbs / 1615kg

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklinBCP 110PS

Precast Foundation For Multiplex Junction Cubicle.

Typical Use: K500, K501, K502 series

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

Cable entry openings-PVC seals for max

4"I.D. duct

1

2

" N.C. Threaded

Inserts

14

73

[5

8"]

1016

[40"]

10

67

[4

2"]

152

[6"]

21

6

[8

1

/2

"]

89

[3

1

/2

"]

17

8

[7

"]

88

9

[3

5"]

16

5

[6

1

/2

"]

165

[6 1/2"]

2" Lifting

hole.

712

[28"]

1016

[40"]

165

[6 1/2"]

203

[8"]

864

[34"]

406

[16"]

1473

[58"]

10

67

[4

2"]

43

2

[1

7"]

114

[4 1/2"]

16

5

[6

1

/2

"]

Galvanized

Steel plate

508

[20"]

86

4

[3

4"]

Page 25: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

Right view

scale:1:30

Front view

scale:1:30

Top view

scale:1:30

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight-3,560lbs / 1615kg

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklinBCP 110PMO

Precast Foundation For Padmount Transformer.

Typical Use: Single Phase Oakville Hydro HS-506A

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

Cable entry openings-PVC seals for max

4"I.D. duct

1

2

" N.C. Threaded

Inserts

14

73

[5

8"]

1016

[40"]

2" Lifting

hole.

712

[28"]

86

4

[3

4"]

1016

[40"]

43

2

[1

7"]

Galvanized

Steel mounting

Bracket

32mm PVC

pipe @ 3"

Galvanized

Steel mounting

Bracket

32mm PVC

pipe @ 3"

12

19

[4

8"]

165

[6 1/2"]

17

8

[7

"]

20

3

[8

"]

203

[8"]

864

[34"]

406

[16"]

1473

[58"]

12

19

[4

8"]

165

[6 1/2"]

16

5

[6

1

/2

"]

16

5

[6

1

/2

"]

Page 26: CONSTRUCTION SPECIFICATIONS Drawn by: O.B Date: …files.armtec.com/Downloads/Categories/Underground-and-Utilities/... · CONSTRUCTION SPECIFICATIONS Concrete: 32MPa, 4600PSI 6-8%

CONSTRUCTION SPECIFICATIONS

Concrete: 32MPa, 4600PSI

6-8% air entrainment

Reinforcement : Steel to CSA CAN A23.1

Weight-18,000lbs / 8,180kg

Drawn by: O.B Date: Feb/2011

armtecconcrete

brooklinBCP 104SM

Foundation for 3 Phase Padmount Transformer.

Typical Use: Mississauga HM-10-101 (up to 1000KVA/1200A)

Front view

scale:1:50

Top view

scale:1:50

Delivery is made by crane-equipped trucks,

excavation must be ready, safe and

accessible for unloading from the rear of

the truck.

Min overhead clearance of 18ft is required.

ALL UNITS MUST BE HANDLED WITH

PROPER LIFTING EQUIPMENT.

(I.E. SPREADER BAR)

Cable entry openings-PVC seals for max

4"I.D. duct

22

86

[9

0"]

2083

[82"]

2692

[106"]

12" Sump pit

15

2

[6

"]

15

2

[6

"]

11

43

[4

5"]

22

86

[9

0"]

15

2

[6

"]

15

2

[6

"]

Right view

scale:1:50

21

59

[8

5"]

2769

[109"]

12

70

[5

0"]

457

[18"]

711

[28"]

11

18

[4

4"]

127

[5"]

203

[8"]

20

3

[8

"]

32

0

[1

2 5

/8

"]

28"x44"

Galvanized Door

w/ lock bar

203

[8"]

20

3

[8

"]

32

0

[1

2 5

/8

"]

305

[12"]

4" Drain

Knockout

Cylindrically Straight

Galvanized

Lock Bar

Padlock

Eyehole4

83

[1

9"]

40

7

[1

6"]