    PROJECT : SOIL INVESTIGASI

    BORING NO.: DB.1 / UDS.1 TESTED BY : Aji

    DEPTH : 3.00 - 3.50 m DATE : 25/03/2014

    LOCATION : Bandara Halim Perdana Kusuma

    DESCRIPT. : Silty Clay, Brownish Red

    APPARATUS MEASUREMENTS SPECIFIC GRAVITY (Gs) 3 2.635

    CONTAINER HEIGHT : 2.000 cm CONTAINER DIAMETER : 5.000 cm SOLIDS HEIGHT (Hs) IN cm : 0.807

    CONTAINER AREA (A) : 19.635 cm2 Hs = Ws/(Gs.w. A)

    DEGREE OF SATURATION IN %

    TEST START : 97.98

    TEST END :

    WATER CONTENT BEGINNING OF TEST END OF TEST

    CONTAINER NO.

    WT. CONTAINER + WET SOIL IN g 127.120

    WT. CONTAINER IN g 62.410

    WT. WET SOIL IN g 64.710

    WT. DRY SOIL (Ws) IN g 41.762 WT. WATER (Ww) IN g 22.95

    WATER CONTENT (w) IN % 54.948

    FINAL DIAL AVERAGE Cv

    DIAL CHANGE e = H/Hs e = eo - e HEIGHT 0.848 H2

    (H) FOR LOAD t 90

    cm cm cm cm2/sec

    0.00 1.0670 1.478 2.000

    0.0373 0.0462 0.00542

    0.25 1.0297 1.432 1.963

    0.0167 0.0207 0.00337

    0.50 1.0130 1.411 1.946

    0.0315 0.0390 0.00672

    1.00 0.9815 1.372 1.915

    0.0365 0.0452 0.00752

    2.00 0.9450 1.327 1.878

    0.0560 0.0694 0.00716

    4.00 0.8890 1.257 1.822

    0.0715 0.0886 0.00501

    8.00 0.8175 1.169 1.751

    0.0170 0.0211

    2.00 0.8345 1.190 1.768

    0.0305 0.0378

    0.25 0.8650 1.227 1.798

    sec

    APPLIED

    PRESSURE

    kg/cm2

    (t 90)

    FITTING

    TIMEH

    cm

    0.880

    0.891

    101.40

    135.00

    0.925

    0.893

    101.40

    0.991

    CONSOLIDATION TEST

    0.977

    0.965

    0.948

    153.60

    240.60

    117.60

  • 7/26/2019 Consolidation Bandara Halim

    2/18

    PROJECT : SOIL INVESTIGASI

    LOCATION : Bandara Halim Perdana Kusuma

    BORING NO. : DB.1 / UDS.1 Coefficient of Consolidation (Cv) : 0.00660 cm2/sec

    DEPTH : 3.00 - 3.50 m Compression Index (Cc) : 0.294

    TESTED BY : Aji Swell Index (Cs) : 0.039

    DATE : 25/03/2014 Coeff. of Volume Comp. (mv) : 0.031 cm2/kg

    DESCRIPTION : Silty Clay, Brownish Red

    CONSOLIDATION TEST

    Cv vs Applied Pressure

    0.00306

    0.00406

    0.00506

    0.00606

    0.00706

    0.00806

    0.100 1.000 10.000

    Pressure, p (kg/cm2)

    Cv(cm2/sec)

    Void Ratio vs Applied Pressure

    1.000

    1.200

    1.400

    1.600

    0.10 1.00 10.00

    Pressure, p (kg/cm2)

    Voidratio(e)

    eo= 1.478

  • 7/26/2019 Consolidation Bandara Halim

    3/18

    PROJECT : SOIL INVESTIGASI

    BORING NO.: DB.1 / UDS.2 TESTED BY : Aji

    DEPTH : 5.50 - 6.00 m DATE : 25/03/2014

    LOCATION : Bandara Halim Perdana Kusuma

    DESCRIPT. : Silty Clay,Reddish Brown

    APPARATUS MEASUREMENTS SPECIFIC GRAVITY (Gs) 3 2.587

    CONTAINER HEIGHT : 2.000 cm CONTAINER DIAMETER : 5.000 cm SOLIDS HEIGHT (Hs) IN cm : 0.782

    CONTAINER AREA (A) : 19.635 cm2 Hs = Ws/(Gs.w. A)

    DEGREE OF SATURATION IN %

    TEST START : 99.65

    TEST END :

    WATER CONTENT BEGINNING OF TEST END OF TEST

    CONTAINER NO.

    WT. CONTAINER + WET SOIL IN g 124.110

    WT. CONTAINER IN g 60.560

    WT. WET SOIL IN g 63.550

    WT. DRY SOIL (Ws) IN g 39.716 WT. WATER (Ww) IN g 23.83

    WATER CONTENT (w) IN % 60.011

    FINAL DIAL AVERAGE Cv

    DIAL CHANGE e = H/Hs e = eo - e HEIGHT 0.848 H2

    (H) FOR LOAD t 90

    cm cm cm cm2/sec

    0.00 1.0330 1.558 2.000

    0.0570 0.0729 0.00610

    0.25 0.9760 1.485 1.943

    0.0250 0.0320 0.00672

    0.50 0.9510 1.453 1.918

    0.0440 0.0563 0.00752

    1.00 0.9070 1.397 1.874

    0.0588 0.0752 0.00711

    2.00 0.8482 1.322 1.815

    0.0802 0.1026 0.00659

    4.00 0.7680 1.219 1.735

    0.0980 0.1253 0.00512

    8.00 0.6700 1.094 1.637

    0.0145 0.0185

    2.00 0.6845 1.112 1.652

    0.0252 0.0322

    0.25 0.7097 1.144 1.677

    CONSOLIDATION TEST

    0.965

    0.948

    0.922

    135.00

    117.60

    101.40

    0.822

    0.832

    101.40

    117.60

    0.888

    0.843

    101.40

    0.986

    sec

    APPLIED

    PRESSURE

    kg/cm2

    (t 90)

    FITTING

    TIMEH

    cm

  • 7/26/2019 Consolidation Bandara Halim

    4/18

    PROJECT : SOIL INVESTIGASI

    LOCATION : Bandara Halim Perdana Kusuma

    BORING NO. : DB.1 / UDS.2 Coefficient of Consolidation (Cv) : 0.00659 cm2/sec

    DEPTH : 5.50 - 6.00 m Compression Index (Cc) : 0.416

    TESTED BY : Aji Swell Index (Cs) : 0.034

    DATE : 25/03/2014 Coeff. of Volume Comp. (mv) : 0.046 cm2/kg

    DESCRIPTION : Silty Clay,Reddish Brown

    CONSOLIDATION TEST

    Cv vs Applied Pressure

    0.00406

    0.00506

    0.00606

    0.00706

    0.00806

    0.100 1.000 10.000

    Pressure, p (kg/cm2)

    Cv(cm2/sec)

    Void Ratio vs Applied Pressure

    1.000

    1.200

    1.400

    1.600

    0.10 1.00 10.00

    Pressure, p (kg/cm2)

    Voidratio(e)

    eo= 1.558

  • 7/26/2019 Consolidation Bandara Halim

    5/18

    PROJECT : SOIL INVESTIGASI

    BORING NO.: DB.1 / UDS.3 TESTED BY : Aji

    DEPTH : 9.50 - 10.00 m DATE : 25/03/2014

    LOCATION : Bandara Halim Perdana Kusuma

    DESCRIPT. : Clayey Silt, Greyish Brown

    APPARATUS MEASUREMENTS SPECIFIC GRAVITY (Gs) 3 2.567

    CONTAINER HEIGHT : 2.000 cm CONTAINER DIAMETER : 5.000 cm SOLIDS HEIGHT (Hs) IN cm : 0.805

    CONTAINER AREA (A) : 19.635 cm2 Hs = Ws/(Gs.w. A)

    DEGREE OF SATURATION IN %

    TEST START : 96.51

    TEST END :

    WATER CONTENT BEGINNING OF TEST END OF TEST

    CONTAINER NO.

    WT. CONTAINER + WET SOIL IN g 123.010

    WT. CONTAINER IN g 59.780

    WT. WET SOIL IN g 63.230

    WT. DRY SOIL (Ws) IN g 40.591 WT. WATER (Ww) IN g 22.64

    WATER CONTENT (w) IN % 55.772

    FINAL DIAL AVERAGE Cv

    DIAL CHANGE e = H/Hs e = eo - e HEIGHT 0.848 H2

    (H) FOR LOAD t 90

    cm cm cm cm2/sec

    0.00 1.0680 1.483 2.000

    0.0400 0.0497 0.00707

    0.25 1.0280 1.434 1.960

    0.0232 0.0288 0.00794

    0.50 1.0048 1.405 1.937

    0.0388 0.0482 0.00507

    1.00 0.9660 1.357 1.898

    0.0500 0.0621 0.00861

    2.00 0.9160 1.295 1.848

    0.0770 0.0956 0.00357

    4.00 0.8390 1.199 1.771

    0.1075 0.1335 0.00463

    8.00 0.7315 1.066 1.664

    0.0135 0.0168

    2.00 0.7450 1.082 1.677

    0.0262 0.0325

    0.25 0.7712 1.115 1.703

    sec

    APPLIED

    PRESSURE

    kg/cm2

    (t 90)

    FITTING

    TIMEH

    cm

    0.835

    0.845

    194.40

    135.00

    0.905

    0.859

    86.40

    0.990

    CONSOLIDATION TEST

    0.974

    0.959

    0.937

    117.60

    101.40

    153.60

  • 7/26/2019 Consolidation Bandara Halim

    6/18

    PROJECT : SOIL INVESTIGASI

    LOCATION : Bandara Halim Perdana Kusuma

    BORING NO. : DB.1 / UDS.3 Coefficient of Consolidation (Cv) : 0.00547 cm2/sec

    DEPTH : 9.50 - 10.00 m Compression Index (Cc) : 0.443

    TESTED BY : Aji Swell Index (Cs) : 0.033

    DATE : 25/03/2014 Coeff. of Volume Comp. (mv) : 0.038 cm2/kg

    DESCRIPTION : Clayey Silt, Greyish Brown

    CONSOLIDATION TEST

    Cv vs Applied Pressure

    0.00306

    0.00406

    0.00506

    0.00606

    0.00706

    0.00806

    0.00906

    0.100 1.000 10.000

    Pressure, p (kg/cm2)

    Cv(cm2/sec)

    Void Ratio vs Applied Pressure

    1.000

    1.200

    1.400

    1.600

    0.10 1.00 10.00

    Pressure, p (kg/cm2)

    Voidratio(e)

    eo= 1.483

  • 7/26/2019 Consolidation Bandara Halim

    7/18

    PROJECT : SOIL INVESTIGASI

    BORING NO.: DB.2 / UDS.1 TESTED BY : Aji

    DEPTH : 3.00 - 3.50 m DATE : 25/03/2014

    LOCATION : Bandara Halim Perdana Kusuma

    DESCRIPT. : Silty Clay, Brownish Red

    APPARATUS MEASUREMENTS SPECIFIC GRAVITY (Gs) 3 2.621

    CONTAINER HEIGHT : 2.000 cm CONTAINER DIAMETER : 5.000 cm SOLIDS HEIGHT (Hs) IN cm : 0.806

    CONTAINER AREA (A) : 19.635 cm2 Hs = Ws/(Gs.w. A)

    DEGREE OF SATURATION IN %

    TEST START : 97.42

    TEST END :

    WATER CONTENT BEGINNING OF TEST END OF TEST

    CONTAINER NO.

    WT. CONTAINER + WET SOIL IN g 123.850

    WT. CONTAINER IN g 59.520

    WT. WET SOIL IN g 64.330

    WT. DRY SOIL (Ws) IN g 41.499 WT. WATER (Ww) IN g 22.83

    WATER CONTENT (w) IN % 55.016

    FINAL DIAL AVERAGE Cv

    DIAL CHANGE e = H/Hs e = eo - e HEIGHT 0.848 H2

    (H) FOR LOAD t 90

    cm cm cm cm2/sec

    0.00 1.0410 1.480 2.000

    0.0435 0.0539 0.00615

    0.25 0.9975 1.426 1.957

    0.0183 0.0227 0.00793

    0.50 0.9792 1.404 1.938

    0.0322 0.0399 0.00580

    1.00 0.9470 1.364 1.906

    0.0420 0.0521 0.00743

    2.00 0.9050 1.312 1.864

    0.0633 0.0785 0.00527

    4.00 0.8417 1.233 1.801

    0.0795 0.0986 0.00248

    8.00 0.7622 1.134 1.721

    0.0208 0.0258

    2.00 0.7830 1.160 1.742

    0.0360 0.0446

    0.25 0.8190 1.205 1.778

    CONSOLIDATION TEST

    0.974

    0.961

    0.943

    135.00

    101.40

    135.00

    0.866

    0.880

    135.00

    264.60

    0.916

    0.880

    101.40

    0.989

    sec

    APPLIED

    PRESSURE

    kg/cm2

    (t 90)

    FITTING

    TIMEH

    cm

  • 7/26/2019 Consolidation Bandara Halim

    8/18

    PROJECT : SOIL INVESTIGASI

    LOCATION : Bandara Halim Perdana Kusuma

    BORING NO. : DB.2 / UDS.1 Coefficient of Consolidation (Cv) : 0.00525 cm2/sec

    DEPTH : 3.00 - 3.50 m Compression Index (Cc) : 0.328

    TESTED BY : Aji Swell Index (Cs) : 0.047

    DATE : 25/03/2014 Coeff. of Volume Comp. (mv) : 0.035 cm2/kg

    DESCRIPTION : Silty Clay, Brownish Red

    CONSOLIDATION TEST

    Cv vs Applied Pressure

    0.00206

    0.00306

    0.00406

    0.00506

    0.00606

    0.00706

    0.00806

    0.00906

    0.100 1.000 10.000

    Pressure, p (kg/cm2)

    Cv(cm2/sec)

    Void Ratio vs Applied Pressure

    1.000

    1.200

    1.400

    1.600

    0.10 1.00 10.00

    Pressure, p (kg/cm2)

    Voidratio(e)

    eo= 1.480

  • 7/26/2019 Consolidation Bandara Halim

    9/18

    PROJECT : SOIL INVESTIGASI

    BORING NO.: DB.2 / UDS.2 TESTED BY : Aji

    DEPTH : 5.50 - 6.00 m DATE : 25/03/2014

    LOCATION : Bandara Halim Perdana Kusuma

    DESCRIPT. : Silty Clay, Brownish Red

    APPARATUS MEASUREMENTS SPECIFIC GRAVITY (Gs) 3 2.614

    CONTAINER HEIGHT : 2.000 cm CONTAINER DIAMETER : 5.000 cm SOLIDS HEIGHT (Hs) IN cm : 0.766

    CONTAINER AREA (A) : 19.635 cm2 Hs = Ws/(Gs.w. A)

    DEGREE OF SATURATION IN %

    TEST START : 92.22

    TEST END :

    WATER CONTENT BEGINNING OF TEST END OF TEST

    CONTAINER NO.

    WT. CONTAINER + WET SOIL IN g 121.230

    WT. CONTAINER IN g 59.560

    WT. WET SOIL IN g 61.670

    WT. DRY SOIL (Ws) IN g 39.332 WT. WATER (Ww) IN g 22.34

    WATER CONTENT (w) IN % 56.793

    FINAL DIAL AVERAGE Cv

    DIAL CHANGE e = H/Hs e = eo - e HEIGHT 0.848 H2

    (H) FOR LOAD t 90

    cm cm cm cm2/sec

    0.00 1.0390 1.610 2.000

    0.0590 0.0770 0.00953

    0.25 0.9800 1.533 1.941

    0.0250 0.0326 0.00778

    0.50 0.9550 1.500 1.916

    0.0420 0.0548 0.00751

    1.00 0.9130 1.445 1.874

    0.0580 0.0757 0.00835

    2.00 0.8550 1.370 1.816

    0.0808 0.1054 0.00435

    4.00 0.7742 1.264 1.735

    0.0957 0.1249 0.00310

    8.00 0.6785 1.139 1.640

    0.0215 0.0281

    2.00 0.7000 1.167 1.661

    0.0400 0.0522

    0.25 0.7400 1.220 1.701

    sec

    APPLIED

    PRESSURE

    kg/cm2

    (t 90)

    FITTING

    TIMEH

    cm

    0.825

    0.841

    153.60

    194.40

    0.888

    0.844

    86.40

    0.985

    CONSOLIDATION TEST

    0.964

    0.948

    0.923

    86.40

    101.40

    101.40

  • 7/26/2019 Consolidation Bandara Halim

    10/18

    PROJECT : SOIL INVESTIGASI

    LOCATION : Bandara Halim Perdana Kusuma

    BORING NO. : DB.2 / UDS.2 Coefficient of Consolidation (Cv) : 0.00583 cm2/sec

    DEPTH : 5.50 - 6.00 m Compression Index (Cc) : 0.415

    TESTED BY : Aji Swell Index (Cs) : 0.053

    DATE : 25/03/2014 Coeff. of Volume Comp. (mv) : 0.047 cm2/kg

    DESCRIPTION : Silty Clay, Brownish Red

    CONSOLIDATION TEST

    Cv vs Applied Pressure

    0.00206

    0.00306

    0.00406

    0.00506

    0.00606

    0.00706

    0.00806

    0.00906

    0.01006

    0.100 1.000 10.000

    Pressure, p (kg/cm2)

    Cv(cm2/sec)

    Void Ratio vs Applied Pressure

    0.800

    1.200

    1.600

    2.000

    0.10 1.00 10.00

    Pressure, p (kg/cm2)

    Vo

    idratio(e)

    eo= 1.610

  • 7/26/2019 Consolidation Bandara Halim

    11/18

    PROJECT : SOIL INVESTIGASI

    BORING NO.: DB.2 / UDS.3 TESTED BY : Aji

    DEPTH : 9.50 - 10.00 m DATE : 25/03/2014

    LOCATION : Bandara Halim Perdana Kusuma

    DESCRIPT. : Silty Clay, Greyish Brown

    APPARATUS MEASUREMENTS SPECIFIC GRAVITY (Gs) 3 2.548

    CONTAINER HEIGHT : 2.000 cm CONTAINER DIAMETER : 5.000 cm SOLIDS HEIGHT (Hs) IN cm : 0.845

    CONTAINER AREA (A) : 19.635 cm2 Hs = Ws/(Gs.w. A)

    DEGREE OF SATURATION IN %

    TEST START : 99.38

    TEST END :

    WATER CONTENT BEGINNING OF TEST END OF TEST

    CONTAINER NO.

    WT. CONTAINER + WET SOIL IN g 125.700

    WT. CONTAINER IN g 60.900

    WT. WET SOIL IN g 64.800

    WT. DRY SOIL (Ws) IN g 42.256 WT. WATER (Ww) IN g 22.54

    WATER CONTENT (w) IN % 53.352

    FINAL DIAL AVERAGE Cv

    DIAL CHANGE e = H/Hs e = eo - e HEIGHT 0.848 H2

    (H) FOR LOAD t 90

    cm cm cm cm2/sec

    0.00 1.0240 1.368 2.000

    0.0348 0.0412 0.00429

    0.25 0.9892 1.327 1.965

    0.0184 0.0218 0.00690

    0.50 0.9708 1.305 1.947

    0.0358 0.0424 0.00584

    1.00 0.9350 1.263 1.911

    0.0450 0.0533 0.00875

    2.00 0.8900 1.209 1.866

    0.0622 0.0736 0.00704

    4.00 0.8278 1.136 1.804

    0.0848 0.1004 0.00487

    8.00 0.7430 1.035 1.719

    0.0140 0.0166

    2.00 0.7570 1.052 1.733

    0.0288 0.0341

    0.25 0.7858 1.086 1.762

    CONSOLIDATION TEST

    0.978

    0.964

    0.944

    194.40

    117.60

    135.00

    0.863

    0.874

    101.40

    135.00

    0.917

    0.881

    86.40

    0.991

    sec

    APPLIED

    PRESSURE

    kg/cm2

    (t 90)

    FITTING

    TIMEH

    cm

  • 7/26/2019 Consolidation Bandara Halim

    12/18

    PROJECT : SOIL INVESTIGASI

    LOCATION : Bandara Halim Perdana Kusuma

    BORING NO. : DB.2 / UDS.3 Coefficient of Consolidation (Cv) : 0.00663 cm2/sec

    DEPTH : 9.50 - 10.00 m Compression Index (Cc) : 0.334

    TESTED BY : Aji Swell Index (Cs) : 0.034

    DATE : 25/03/2014 Coeff. of Volume Comp. (mv) : 0.033 cm2/kg

    DESCRIPTION : Silty Clay, Greyish Brown

    CONSOLIDATION TEST

    Cv vs Applied Pressure

    0.00306

    0.00406

    0.00506

    0.00606

    0.00706

    0.00806

    0.00906

    0.100 1.000 10.000

    Pressure, p (kg/cm2)

    Cv(cm2/sec)

    Void Ratio vs Applied Pressure

    1.000

    1.100

    1.200

    1.300

    1.400

    0.10 1.00 10.00

    Pressure, p (kg/cm2)

    Void

    ratio(e)

    eo= 1.368

  • 7/26/2019 Consolidation Bandara Halim

    13/18

    PROJECT : SOIL INVESTIGASI

    BORING NO.: DB.3 / UDS.1 TESTED BY : Aji

    DEPTH : 3.00 - 3.50 m DATE : 25/03/2014

    LOCATION : Bandara Halim Perdana Kusuma

    DESCRIPT. : Silty Clay, Reddish Brown

    APPARATUS MEASUREMENTS SPECIFIC GRAVITY (Gs) 3 2.528

    CONTAINER HEIGHT : 2.000 cm CONTAINER DIAMETER : 5.000 cm SOLIDS HEIGHT (Hs) IN cm : 0.667

    CONTAINER AREA (A) : 19.635 cm2 Hs = Ws/(Gs.w. A)

    DEGREE OF SATURATION IN %

    TEST START : 97.84

    TEST END :

    WATER CONTENT BEGINNING OF TEST END OF TEST

    CONTAINER NO.

    WT. CONTAINER + WET SOIL IN g 121.040

    WT. CONTAINER IN g 62.310

    WT. WET SOIL IN g 58.730

    WT. DRY SOIL (Ws) IN g 33.132 WT. WATER (Ww) IN g 25.60

    WATER CONTENT (w) IN % 77.263

    FINAL DIAL AVERAGE Cv

    DIAL CHANGE e = H/Hs e = eo - e HEIGHT 0.848 H2

    (H) FOR LOAD t 90

    cm cm cm cm2/sec

    0.00 1.0410 1.996 2.000

    0.0995 0.1491 0.00795

    0.25 0.9415 1.847 1.901

    0.0355 0.0532 0.00870

    0.50 0.9060 1.794 1.865

    0.0650 0.0974 0.00702

    1.00 0.8410 1.697 1.800

    0.1138 0.1705 0.00548

    2.00 0.7272 1.526 1.686

    0.1532 0.2295 0.00283

    4.00 0.5740 1.297 1.533

    0.1780 0.2667 0.00327

    8.00 0.3960 1.030 1.355

    0.0230 0.0345

    2.00 0.4190 1.064 1.378

    0.0508 0.0761

    0.25 0.4698 1.141 1.429

    sec

    APPLIED

    PRESSURE

    kg/cm2

    (t 90)

    FITTING

    TIMEH

    cm

    0.683

    0.702

    194.40

    135.00

    0.805

    0.722

    117.60

    0.975

    CONSOLIDATION TEST

    0.941

    0.916

    0.872

    101.40

    86.40

    101.40

  • 7/26/2019 Consolidation Bandara Halim

    14/18

    PROJECT : SOIL INVESTIGASI

    LOCATION : Bandara Halim Perdana Kusuma

    BORING NO. : DB.3 / UDS.1 Coefficient of Consolidation (Cv) : 0.00465 cm2/sec

    DEPTH : 3.00 - 3.50 m Compression Index (Cc) : 0.886

    TESTED BY : Aji Swell Index (Cs) : 0.073

    DATE : 25/03/2014 Coeff. of Volume Comp. (mv) : 0.080 cm2/kg

    DESCRIPTION : Silty Clay, Reddish Brown

    CONSOLIDATION TEST

    Cv vs Applied Pressure

    0.00206

    0.00306

    0.00406

    0.00506

    0.00606

    0.00706

    0.00806

    0.00906

    0.100 1.000 10.000

    Pressure, p (kg/cm2)

    Cv(cm2/sec)

    Void Ratio vs Applied Pressure

    0.800

    1.000

    1.200

    1.400

    1.600

    1.800

    2.000

    2.200

    0.10 1.00 10.00

    Pressure, p (kg/cm2)

    Voidratio(e)

    eo= 1.996

  • 7/26/2019 Consolidation Bandara Halim

    15/18

    PROJECT : SOIL INVESTIGASI

    BORING NO.: DB.3 / UDS.2 TESTED BY : Aji

    DEPTH : 5.50 - 6.00 m DATE : 25/03/2014

    LOCATION : Bandara Halim Perdana Kusuma

    DESCRIPT. : Silty Clay, Brownish Red

    APPARATUS MEASUREMENTS SPECIFIC GRAVITY (Gs) 3 2.580

    CONTAINER HEIGHT : 2.000 cm CONTAINER DIAMETER : 5.000 cm SOLIDS HEIGHT (Hs) IN cm : 0.799

    CONTAINER AREA (A) : 19.635 cm2 Hs = Ws/(Gs.w. A)

    DEGREE OF SATURATION IN %

    TEST START : 97.79

    TEST END :

    WATER CONTENT BEGINNING OF TEST END OF TEST

    CONTAINER NO.

    WT. CONTAINER + WET SOIL IN g 123.300

    WT. CONTAINER IN g 59.770

    WT. WET SOIL IN g 63.530

    WT. DRY SOIL (Ws) IN g 40.467 WT. WATER (Ww) IN g 23.06

    WATER CONTENT (w) IN % 56.992

    FINAL DIAL AVERAGE Cv

    DIAL CHANGE e = H/Hs e = eo - e HEIGHT 0.848 H2

    (H) FOR LOAD t 90

    cm cm cm cm2/sec

    0.00 1.0950 1.504 2.000

    0.0330 0.0413 0.00823

    0.25 1.0620 1.462 1.967

    0.0252 0.0315 0.00937

    0.50 1.0368 1.431 1.942

    0.0498 0.0623 0.00902

    1.00 0.9870 1.368 1.892

    0.0540 0.0676 0.00627

    2.00 0.9330 1.301 1.838

    0.0720 0.0901 0.00448

    4.00 0.8610 1.211 1.766

    0.0990 0.1239 0.00407

    8.00 0.7620 1.087 1.667

    0.0250 0.0313

    2.00 0.7870 1.118 1.692

    0.0470 0.0588

    0.25 0.8340 1.177 1.739

    CONSOLIDATION TEST

    0.977

    0.958

    0.933

    101.40

    86.40

    86.40

    0.840

    0.858

    153.60

    153.60

    0.901

    0.858

    117.60

    0.992

    sec

    APPLIED

    PRESSURE

    kg/cm2

    (t 90)

    FITTING

    TIMEH

    cm

  • 7/26/2019 Consolidation Bandara Halim

    16/18

    PROJECT : SOIL INVESTIGASI

    LOCATION : Bandara Halim Perdana Kusuma

    BORING NO. : DB.3 / UDS.2 Coefficient of Consolidation (Cv) : 0.00596 cm2/sec

    DEPTH : 5.50 - 6.00 m Compression Index (Cc) : 0.412

    TESTED BY : Aji Swell Index (Cs) : 0.060

    DATE : 25/03/2014 Coeff. of Volume Comp. (mv) : 0.038 cm2/kg

    DESCRIPTION : Silty Clay, Brownish Red

    CONSOLIDATION TEST

    Cv vs Applied Pressure

    0.00306

    0.00406

    0.00506

    0.00606

    0.00706

    0.00806

    0.00906

    0.01006

    0.100 1.000 10.000

    Pressure, p (kg/cm2)

    Cv(cm2/sec)

    Void Ratio vs Applied Pressure

    1.000

    1.100

    1.200

    1.300

    1.400

    1.500

    1.600

    0.10 1.00 10.00

    Pressure, p (kg/cm2)

    Void

    ratio(e)

    eo= 1.504

  • 7/26/2019 Consolidation Bandara Halim

    17/18

    PROJECT : SOIL INVESTIGASI

    BORING NO.: DB.3 / UDS.3 TESTED BY : Aji

    DEPTH : 9.00 - 9.50 m DATE : 25/03/2014

    LOCATION : Bandara Halim Perdana Kusuma

    DESCRIPT. : Silty Clay, Brownish Red

    APPARATUS MEASUREMENTS SPECIFIC GRAVITY (Gs) 3 2.601

    CONTAINER HEIGHT : 2.000 cm CONTAINER DIAMETER : 5.000 cm SOLIDS HEIGHT (Hs) IN cm : 0.781

    CONTAINER AREA (A) : 19.635 cm2 Hs = Ws/(Gs.w. A)

    DEGREE OF SATURATION IN %

    TEST START : 89.48

    TEST END :

    WATER CONTENT BEGINNING OF TEST END OF TEST

    CONTAINER NO.

    WT. CONTAINER + WET SOIL IN g 115.980

    WT. CONTAINER IN g 54.690

    WT. WET SOIL IN g 61.290

    WT. DRY SOIL (Ws) IN g 39.865 WT. WATER (Ww) IN g 21.42

    WATER CONTENT (w) IN % 53.742

    FINAL DIAL AVERAGE Cv

    DIAL CHANGE e = H/Hs e = eo - e HEIGHT 0.848 H2

    (H) FOR LOAD t 90

    cm cm cm cm2/sec

    0.00 1.0520 1.562 2.000

    0.0270 0.0346 0.00545

    0.25 1.0250 1.528 1.973

    0.0140 0.0179 0.00533

    0.50 1.0110 1.510 1.959

    0.0280 0.0359 0.00463

    1.00 0.9830 1.474 1.931

    0.0370 0.0474 0.00659

    2.00 0.9460 1.426 1.894

    0.0580 0.0743 0.00232

    4.00 0.8880 1.352 1.836

    0.0690 0.0884 0.00146

    8.00 0.8190 1.264 1.767

    0.0222 0.0284

    2.00 0.8412 1.292 1.789

    0.0393 0.0503

    0.25 0.8805 1.342 1.829

    sec

    APPLIED

    PRESSURE

    kg/cm2

    (t 90)

    FITTING

    TIMEH

    cm

    0.889

    0.904

    317.40

    470.40

    0.933

    0.901

    117.60

    0.993

    CONSOLIDATION TEST

    0.983

    0.973

    0.956

    153.60

    153.60

    173.40

  • 7/26/2019 Consolidation Bandara Halim

    18/18

    PROJECT : SOIL INVESTIGASI

    LOCATION : Bandara Halim Perdana Kusuma

    BORING NO. : DB.3 / UDS.3 Coefficient of Consolidation (Cv) : 0.00375 cm2/sec

    DEPTH : 9.00 - 9.50 m Compression Index (Cc) : 0.294

    TESTED BY : Aji Swell Index (Cs) : 0.052

    DATE : 25/03/2014 Coeff. of Volume Comp. (mv) : 0.026 cm2/kg

    DESCRIPTION : Silty Clay, Brownish Red

    CONSOLIDATION TEST

    Cv vs Applied Pressure

    0.00106

    0.00206

    0.00306

    0.00406

    0.00506

    0.00606

    0.00706

    0.100 1.000 10.000

    Pressure, p (kg/cm2)

    Cv(cm2/sec)

    Void Ratio vs Applied Pressure

    1.200

    1.300

    1.400

    1.500

    1.600

    0.10 1.00 10.00

    Pressure, p (kg/cm2)

    Void

    ratio(e)

    eo= 1.562