background
A contract chemical manufacturer synthesizes halogenated aromatic reference standards for use
in environmental analysis and toxicological research; compound types include chlorinated dioxins
(PCDDs), chlorinated dibenzofurans (PCDFs) and chlorinated biphenyls (PCBs).
In its more than 20 years of operation, the company has become well-known and respected within
the environmental industry, participating in the validation of U.S. EPA and Environment Canada
analytical testing methods as well as analyzing and certifying reference matrices for the NRCC,
Environment Canada and NBS/NIST. The company’s products are sold worldwide through specialty
chemical distributors.
cHaLLEngE
The company produces hundreds of chemicals that are used in a variety of solutions and calibra-
tion sets. Prior to the production and distribution of the final product, all compounds must be
rigorously tested for chemical and isotopic purity. To this end, the company employs a number of
different analytical instruments, including high performance liquid chromatography (HPLC) and
mass spectrometry (MS).
To improve the quality of sample testing, the company sought a new LC/MS solution that would
provide enhanced data resolution. Given a sample turnaround schedule that involves performing
hundreds of analyses on a weekly basis, it was critical that the solution be robust, experiencing
little or no downtime. In addition to innovative instrument technology, the company required
world-class service and support to ensure that utility of this new instrumentation was maximized.
T HE SoLuT Ion
To improve data resolution, the company chose the Waters ACQUITY UPLC® System and the
Waters Quattro micro™ API Mass Spectrometer. The ACQUITY UPLC System synergistically com-
bines unique instrumentation capabilities, column chemistries and software to yield dramatically
improved analytical resolution, sensitivity and speed. Combined with the Quattro micro API, a
tandem quadrupole instrument, the ACQUITY UPLC System has allowed the company to generate
better-resolved sample data in less time.
To ensure the highest instrument utilization, the ACQUITY UPLC System was installed with
Waters Connections INSIGHT®, an intelligent service delivery platform that provides continuous
monitoring and instant-alert notifications for faster, proactive support that prevents problems
from occurring. Specific information such as system usage, operational parameters and diagnostic
information is securely transmitted to Waters Technical Support.
co nn ec t io ns ins ig h t
reducing instrument down-time in an analytical laboratoryThe client: Contract manufacturer of environmental testing standards
“Without Connections INSIGHT
software, I would have lost an
entire day’s worth of work.”
–QCchemist
[ business solution ]
Three levels of reporting are provided:
n Periodic Status Log (Level 1): Provides basic system performance
information, including lamp hours, injection counters, ambient
temperature, pressure and fluid volume delivered. This
information is used to proactively determine the maintenance
schedule for the instrument.
n System Alert (Level 2): At this level, an automatic notification
of system failures is sent directly to Waters Technical Support.
System alerts are generated when the Connections INSIGHT
Agent encounters a significant system performance parameter.
This automatically triggers an email alert that is delivered via
a secure Internet connection to the Technical Support team, who
analyzes the information. The local Field Service Engineer is
notified and contacts the customer to take the appropriate action.
If necessary, parts are ordered for next-day delivery and the
engineer is proactively dispatched to the customer site.
n Customer Initiated Request (Level 3): With a push of a button,
the customer can ask for help via “Submit Connections INSIGHT
Request” functionality. When selected, it zips the service profile
file – containing detailed troubleshooting information – and
automatically sends an email alert to Waters Technical Support.
The file is reviewed and the appropriate action is initiated: the
customer receives either a call from Technical Support or a visit
from the Field Service Engineer.
buSInESS bEnEFIT
Since installation of the ACQUITY UPLC System in the customer’s
laboratory, Connections INSIGHT has detected two system errors.
In each case, within 15 minutes of the incident, Waters Technical
Support notified the customer of the system error and provided a
solution. No service call was needed, and the customer was able to
make necessary corrections.
“ Without Connections INSIGHT software, I would have lost an entire
day’s worth of work. The value of Connections INSIGHT technology
is that it provides early warning of system issues that can be fixed
quickly – and in most cases, eliminates the need for an on-site
visit that reduces unplanned downtime so that our laboratories can
maintain system uptime,” said the lab’s QC chemist.
The proactive alert system prevented the contract chemical manu-
facturer from losing valuable instrument time, which would have
negatively impacted product delivery schedules and their customers’
satisfaction. The company has seen additional benefits from using
Connections INSIGHT, including:
n A reduction in the time spent assessing and diagnosing the
problem with Waters Technical Support – and more time for
analyses
n Connections INSIGHT’s request option allows them to directly
access Waters Technical Support for faster problem resolution
n The ability to predict potential problems by monitoring component
and consumable usage – saving time and money, and maintaining
uptime
n Greater laboratory productivity and lower instrument support costs
n Reporting to document instrument history for auditing requirements
The Connections INSIGHT service and support program is available
for Waters customers who are covered under an ACQUITY UPLC
System Warranty or Total Assurance Plan, at no additional cost.