connection and safety catalog for photovoltaic installations

24
Connection and Safety Catalog for Photovoltaic Installations [email protected] · [email protected] · www.sofamel.com

Upload: others

Post on 04-Jun-2022

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Connection and Safety Catalog for Photovoltaic Installations

Connection and Safety Catalogfor Photovoltaic Installations

[email protected] · [email protected] · www.sofamel.com

Page 2: Connection and Safety Catalog for Photovoltaic Installations

2

OFFICE AND WAREHOUSEC/ Thomas Alva Edison, 16-17Pol. Industrial Plans d’Arau08787 La Pobla de Claramunt(Barcelona) España

FACTORY AND LABORATORYC/ Thomas Alva Edison, 12-13Pol. Industrial Plans d’Arau08787 La Pobla de Claramunt (Barcelona) España

CUSTOMER SERVICETel. +34 93 808 79 [email protected]@sofamel.es

www.sofamel.com

Page 3: Connection and Safety Catalog for Photovoltaic Installations

3

Sofamel S.L. is a Spanish company dedicated to the production of electrical materialof connection, as well as safety and electric protection material.

Sofamel’s main objective has been to reach a high degree of specialization with the aim of

providing a global solution for our clients. The same backed up by strict quality standards and by

important investments in machinery and design for the manufacturing of all those products that

that exists on the market.

Our commitment with excellent quality work allows our company to own the quality management

Page 4: Connection and Safety Catalog for Photovoltaic Installations

44

Page 5: Connection and Safety Catalog for Photovoltaic Installations

5

index

CONNECTIONConnections for photovoltaic cables

Copper connectors

Bimetallic connectors

Piercing connectors

Heat shrink

Earthing rods clamps and battery connections

TOOLSCortacables manuales

Wire and cable strippers

Crimping tool

SAFETYPersonal protection elements

Insulation elements

Earthing and short circuit equipment

Personal voltage detectors

Insulating poles

MATERIAL FOR WORK AT HEIGHTEverything you need for your personal protection

10

11

12

13

13

14

16

17

18

18

18

19

20

Page 6: Connection and Safety Catalog for Photovoltaic Installations

12

7

6

3

4

6

5

6

Photovoltaic power plantsConnectors forthe wiring

1

Insulating piercing connectorsfor Cu or Al cable

4

Fuses

2

Brass connectors for connecting to structure

7

Pre-insulated terminals

Neutral earthing switch

5

Copper compression clamp

Earthing clamp

Setscrew joint

5

Copper tubular terminals

3

6

6

Aluminum and bimetalliccable lug

Battery terminals

66

Page 7: Connection and Safety Catalog for Photovoltaic Installations

7

6

Photovoltaic power plants

Brass connectors for connecting to structure

7

Copper compression clamp

Earthing clamp

Setscrew joint

Earthing clamp

w joint

5

6

Aluminum and bimetalliccable lug

7

Page 8: Connection and Safety Catalog for Photovoltaic Installations

Copper tubular terminalsCopper tterminals4

Tap-off connectors

3

Connectors forthe wiring

1

Fuses

2

Fuses

2

1

2

5

4

3

6

88

Page 9: Connection and Safety Catalog for Photovoltaic Installations

Self-consumption

Pre-insulated terminals

Neutral earthing switch

5

6

Copper compression clamp

Earthing clampSetscrew joint clampEarthing cetscrew joint

Brass connectors for connecting to structure

7

Solar optimiser

7

8

88

9

Page 10: Connection and Safety Catalog for Photovoltaic Installations

1010

ConnectionCONNECTIONS FOR PHOTOVOLTAIC CABLES

501 SCF/OPTSolar optimiser

SCF/OPT power optimisers to connect to solar panels: used to reduce losses from a photovoltaic system and therefore increase system efficiency.

501 SCF/CMC4 type connectors for 1000 V and 1500 V

MC4 type connectors, male and female: ensure a good connection and water tightness between the wiring terminations and the various elements that make up a photovoltaic installation.

SCF/C-1000V for cross-sections of between 2.5 and 6 mm² SCF/C-1500V-A for cross-sections of between 2.5 and 6 mm²SCF/C-1500V-B for 10 mm² cross-sectionsA cable crimper is required for correct installation.

501 SCF/D-TLTap-off connectors with flexible hose

MC4 type flexible connectors for connecting strings in parallel.

SCF/D-2TL-1500V for connecting 2 to 1 and 1500 V isolationSCF/D-3TL-1500V for connecting 3 to 1 and 1500 V isolation

501 SCF/FUSEMC4 TYPE fuse holder for 1500 V

Integrated, watertight 20 A fuse in MC4 connector.Fuse dimensions: 10x85 mm. Possibility of changing fuse (from 10 A to 50 A).

SCF/FUSE-1500V, female-male.

501 SCF/D-TTap-off connectors

MC4 type rigid connectors for con-necting strings in parallel.

SCF/D-2T-1500V for connecting 2 to 1 and 1500 V isolationSCF/D-3T-1500V for connecting 3 to 1 and 1500 V isolation

Page 11: Connection and Safety Catalog for Photovoltaic Installations

11

Connection

010 TCopper cable lug

T cable lug manufactured from electrolytic copper with a

inspection hole to check the correct cable positioning.

According to IEC 61238-1-3 standard.

007 T45°

-tation makes it suitable for installations where connection

According to IEC 61238-1-3 standard.

006 TLCopper cable lug long barrel

TL cable lug manufactured from electrolytic copper with a

The larger length of the barrel guarantees a better electrical connection in unfavorable conditions.

According to IEC 61238-1-3-3 standard.

008 T90°

Its particular orientation makes it suitable for installations

According to IEC 61238-1-3 standard.

Page 12: Connection and Safety Catalog for Photovoltaic Installations

1212

Connection

111 TDC/SBimetallic cable lug

The complete cable lug surface is tinned by means of an electrolytic process. Incorporates neutral grease to avoid aluminium oxidation.It is especially designed for underground cable connections.

101 TTGShear head bolt cable lug

TTG cable lugs are manufactured from high conductivity

by means of an electrolytic process.

110 TBFBimetallic cable lug

The palm is manufactured with forged copper.The two parts of the bimetallic cable lug are joined through a friction stir welding process. Incorporates neutral grease to avoid aluminium oxidation.

Electric test according to CEI 61238-1 standard.Tested under IEC 61238 standard.

103 TTGAInsulated terminals with shear head bolts

TTGA cable lugs are manufactured from high-conductivity

lug surface using a tinplating process.

grey, and neutral in blue.

PRODUCTOCERTIFICADO

Page 13: Connection and Safety Catalog for Photovoltaic Installations

13

136 ABT

ABT piercing connectors are made from 6.6 polyamide with

by piercing the main and tap cables.

377 TPMAMedium-walled heat shrink tube with adhesive

TPMA tubes possess an excellent isolation, watertight seal, and abrasion and impact resistance. They are used in low voltage electrical applications and provide an excellent mechanical protection.

Connection

Page 14: Connection and Safety Catalog for Photovoltaic Installations

1414

170 GTR Earthing clamp

-less steel screws. With high robustness, they are designed for earthing connections.

501 SCF/BBBattery terminals

Set of 2 brass terminals for connecting the cable to the

T50 TGT142Earthing rod clamps

Earthing rod clamp manufactured from brass with galvanized steel ring.

T50 TGT142 RF

Earthing rod clamp manufactured from brass from galvanized steel ring.The cable tie walls thickness improves the safety and

earthing rods.

Connection

Page 15: Connection and Safety Catalog for Photovoltaic Installations

15

Tools

380 SF-21Cable cutters

-bles up to 16 mm².

400 SF-22Wire and cable strippers

385 SF-MC4Crimp tool

Crimping tool for solar connectors

installations.

Page 16: Connection and Safety Catalog for Photovoltaic Installations

1616

Safety

530 SG

The natural latex base has excellent dielectric properties.The thicker the glove, the greater the electrical resistance.The ergonomic design provides comfort and a smoother

easily.

539 SGLeather overgloves

Leather overgloves must be worn over dielectric gloves to protect against mechanical risks as well as against possi-ble electric arc risks. These leather cowhide gloves with

-cro strap on the back of the hand.

The cowhide leather is treated with silicone to increase its waterproof characteristics.

531 SGMInsulated gloves

Composite insulated gloves provide electrical, mechanical

combined with any other kind of glove with mechanical protection.

The Composite glove range is made using a natural latex base covered by an outer layer of polychloroprene, combining mechanical resistance and comfort with a high level of protection.

properties in the event of a short circuit in the electric arc.

535 SG-37

-ties.They are used under dielectric gloves with the aim of protecting against a possible electric arc.

Page 17: Connection and Safety Catalog for Photovoltaic Installations

17

565 ARMOURSafety helmets for protection from mechanical and electrical hazards

ABS helmet complete with a 1.7 mm thick polycarbonate face shield. The head circumference of the hard hat can be

point height adjustment.

580 STInsulating stool for indoor use

Made of high impact copolymer polypropylene.The platform surface is rough and non-slip.

-

585 ADClass 0, 2, 3 and 4 insulating mat

3

71 Shore A2

2

182 mm3

According to IEC 61111.

580 STEInsulating stool for outdoor use

Made of high impact copolymer polypropylene.The platform surface is rough, non-slip and the legs have

-

Safety

Page 18: Connection and Safety Catalog for Photovoltaic Installations

Seguridad

18

Safety

EARTHING AND SHORT CIRCUIT EQUIPMENTThe main aim for its installation is operator’s protection against an accidental commissioning or possible voltage return during repair operations.

The earthing and short-circuit equipment for low voltage electrical panels comply with the IEC 61230 standard.

Possibility of customizing any equipment.

618 BSC-MConnectable multiuse poles

Indoor and Outdoor use in humid environment

with polyurethane foam that complies

(Hexagonal)Includes carrying bag.

617 BMAEConnectable poles

Connectable poles with two sections,

each end, hand protector, grip, tip and

or P (Hexagonal + Metric-10) head.

635 TESTER PDOptical & Acoustic

A two-pole voltage tester with phase discriminator, optical

test.

Page 19: Connection and Safety Catalog for Photovoltaic Installations

19

691 KRM-4001Manoeuvring and rescue kit

with bag1 rescue hook with universal head1 pair of dielectric gloves SG-40 T10 stored in a nylon bag

1 respiration pipette1 neck immobilizer

1 stretcher

690 SZ-51M

Composed of a 1 x 1.6 m board that contains the following

1 plastic case for gloves1 pair of dielectric gloves (class 3)

1 pipette

1 pair of insulating shoes

1 instruction plate

Safety

Page 20: Connection and Safety Catalog for Photovoltaic Installations

2020

Material for work at height

550 SO-06Support belt with rope

550 SO-74Steel symmetrical karabiner

550 SO-71 550 S/ATCSafety harness with belt

565 S/CABS-397Safety helmet

550 S/MOALAluminium asymmetrical karabiner

Page 21: Connection and Safety Catalog for Photovoltaic Installations

21

550 S/ADM-353Sliding fall arrest device

550 SO-07Adjustable rope

550 S/ELAR-354Adjustable rope

550 S/CSE-353Semi-static rope

550 SO-75Lifeline cord

Material for work at height

Page 22: Connection and Safety Catalog for Photovoltaic Installations
Page 23: Connection and Safety Catalog for Photovoltaic Installations
Page 24: Connection and Safety Catalog for Photovoltaic Installations

OFFICE AND WAREHOUSEC/ Thomas Alva Edison, 16-17Pol. Industrial Plans d’Arau08787 La Pobla de Claramunt(Barcelona) España

FACTORY AND LABORATORYC/ Thomas Alva Edison, 12-13Pol. Industrial Plans d’Arau08787 La Pobla de Claramunt (Barcelona) España

[email protected] - [email protected]

Customer service