configuration and typical wiring diagrams
TRANSCRIPT
N/A
Step Press Button(s) COMMENTSPress or to select: Displayed
(Factory Default)
HOLD(0:00)
0 to 8 hrs (in 15 minute increments)
2(FA)
SL
Select temporary Hold time
N/A
N/A
E(ON)
OFF
4
5
LOC(OFF)
ON
0 HI(0)
4 LO to4 HI
°(F) °C
Returns to normal operation
Returns to normal operation
6
7
Select Energy Management Recovery OFF or ON
Select Compressor lockout OFF or ON
Select temperature display adjustment higher or lower
Select temperature display to °F or °C
RUN
PRGMand RUN
*
*
3 d-L(ON)
OFF Select display backlight OFF or ON*
*
Filter(000)
0 to 1950 hours(in 50 hour increments)
Select filter replacement run time*
*
*
Select FA or SL (Fast or Slow) heating cycle rate
Configuration Menu
N/A
Step
2
N/A
4
5
6
7
8
3
1
Step
2
4
5
6
7
8
9
3
1
1 SYSTEM switch must be OFF to configure thermostatoptions
Set SYSTEMswitch to OFF
Set SYSTEMswitch to HEAT
or COOL
1N/AN/A
N/AN/A
N/AN/A
Step
2
4
N/A
5
6
7
8
3
1F80
-241
1F80
-361
1F86
-241
1F86
-344
1F87-361 Press Button(s)
RUN
1
HOLD*
HOLD*
HOLD*
HOLD*
HOLD*
HOLD*
HOLD*
N/A
1
N/A
*9
Step
2
4
5
N/A
6
7
8
3
*1F8
0-24
0
1
N/A
8
Step
2
N/A
N/A
4
5
6
7
3
1F80
-224
* 1F80/1F87 - Press HOLD to advance to next item or TIME to move backwards to previous item1F86 - Press and to advance to next item1F80-240 is HEAT only
RH
24 VAC 120 VAC
Hot
Neutral
THERMOSTAT
SYSTEMG W
Heat only, 3-wire, single transformer systems
TRANSFORMER
HeatingSystem
FanRelay
YC‡ RC
JUMPERWIRE
OB
For 1F80-361 and 1F86-344 2-wire Heat only, attach to RH and W.
NOTE
RHY
24 VAC 120 VAC
Hot
Neutral
TRANSFORMER
THERMOSTAT
SYSTEMG W
Cool only, 3-wire, single transformer systems
CoolingSystem
FanRelay
RCOBC‡
JUMPERWIRE
RHY
24 VAC 120 VAC
Hot
Neutral
THERMOSTAT
SYSTEMG W
Heat/cool, 4-wire, single transformer systems
TRANSFORMER
HeatingSystem
FanRelay
CoolingSystem
RC
JUMPERWIRE
OC‡ B
RED jumper wire (provided with thermostat) must be connected between thermostat RH and RC terminals for proper thermostat operation with this system.
NOTE
RHY
24 VAC 120 VAC
Hot
Neutral
THERMOSTAT
SYSTEMG W
Heat/cool, 5-wire, two-transformer systems
HEATINGTRANSFORMER
HeatingSystem
FanRelay
CoolingSystem
RC
24 VAC 120 VAC
Hot
Neutral
COOLING TRANSFORMER
OBC‡
RHY
24 VAC 120 VAC
Hot
Neutral
THERMOSTAT
SYSTEMG W
Heat pump with reversing valve energized in COOLTRANSFORMER
ReversingValve*
RCOBC‡
JUMPERWIRE
CompressorContactor
JUMPERWIRE
* Reversing valve is energized when the system switch is in the COOL position
FanRelay
RHY
24 VAC 120 VAC
Hot
Neutral
THERMOSTAT
SYSTEMG W
Heat pump with reversing valve energized in HEATTRANSFORMER
ReversingValve*
RCOBC‡
JUMPERWIRE
CompressorContactor
JUMPERWIRE
* Reversing valve is energized when the system switch is in the HEAT position
FanRelay
The following table allows you to customize the options on your Comfort-Set thermostat.
1F80-224 / 1F80-240 / 1F80-241/1F80-3611F86-241 / 1F86-344 / 1F87-361
CONFIGURATION ANDTYPICAL WIRING DIAGRAMS
CONFIGURATION
TYPICAL WIRING DIAGRAMS
TEC
HN
ICA
L H
ELP
www.white-rodgers.com 157