concrete scanning report · 156 onslow road, shenton park wa 6008 tel: (08) 938 82810...
TRANSCRIPT
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible
for inaccurate or false interpretation of data, images or reports relating to target service locations. Design and structural interpretations or opinions expressed by the
company or its technicians must be verified by a suitably qualified professional engineer.
P: 08 9294 1832
F: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Concrete Scanning Report
JOB DOCKET
Date: ................................. Purchase Order No: ...............................................................
Site Contact ...........................................................................
Telephone No: ......................................................... Email ......................................................................................
Site Location: .....................................................................................................................................................................
Scan Type:
Scan Report Required? .............................................. Photo’s Required? .........................................................
Pre-site Safety Checklist
On arrival at the site, tick the correct answer where relevant to the job. If the answer is NO the situation is unsafe.
Alert the office.
YES NO YES NO
INDUCTION REQUIRED VENTILATION ADEQUATE
FIRST AID LOCATED/ACCESSIBLE SCAFFOLDING ERECTED
SAFETY EQUIPMENT FUNCTIONAL FALL PROTECTION IN PLACE
ELECTRIC LEADS OPERATIONAL EQUIPMENT
In good condition and safe In good working order
Correctly Tagged Components operational / safe
PROTECTIVE CLOTHING HAZARDOUS SUBSTANCES
Suitable Identified
Fit for duty LIGHTING SUITABLE
Disclaimer: Whilst every effort is taken to give an accurate assessments of all articles detected beneath the concrete surface by radar operating personnel. United Scanning Services and its Affiliates do not take any responsibility if any article is detected incorrectly or not detected by the radar or radar operating personnel. By reading and signing this you understand that no responsibility will be accepted for any damage caused whatsoever.
USS Rep: ................................................................. Client Rep: .................................................................
Print Name: .............................................
United Scanning Services Pty Ltd
A: PO BOX 3029 Midland, WA 6056 P: (08) 9294 1832 M: 0433 724 921 F: (08) 9294 1832 E: [email protected] W: unitedscanning.com.au
DOCKET No.
Return to Site Required?
Company Name: ......................................................
Print Name: .............................
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible
for inaccurate or false interpretation of data, images or reports relating to target service locations. Design and structural interpretations or opinions expressed by the
company or its technicians must be verified by a suitably qualified professional engineer.
P: 08 9294 1832
F: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
1. Scanning Results
To whom it may concern,
This document is to state that Ground Penetrating Radar Scanning was undertaken by UNITED SCANNING SERVICES
PTY LTD on the:
Scanning was undertaken in the following location:
Description of Works Completed:
If you require any more information, please let us know.
UP
VOID
VOID
11
GF H I JE
4
3
2
5
6
7
9
A
B
10
C
D
1
8
CC
1C
C1
CC
1
CC
1
CC
2
CC
1
CC
1
CC
1
CC
1
CC
1
CC
1
CC
1
CC
1
CC
1
CC
1
CC
1
CC
1
W1
W1
W1A
W1A
W1A
W1
RW1
RW1
W9
W1A
W9
W9
W9
W2
W2
W2
W2
W2W2
RW2
W2
RW2
W9
W9
CC
1
W2
W2
W9
W9
W1
W1
W1B-A
S12
B-B
S12
STAIR 4
STAIR 2
B-D
S12
B-C
S12BB-P
S14
BB-H
S13
BB-F
S13
BB-E
S13
BB-A
S13
BB-B
S13
BB-C
S13
BB-D
S13
BB-G
S13
W9W9
W10
W2
W2
W2
W1A
W10
300
MASS CONCRETE LIFT PIT BASE FROM RAFT TOLIFT PIT LEVEL.
ALTERNATIVELY, PROVIDE COMPACTED SAND FILLAND PROVIDE A 250 THICK SLAB WITH N12-200EACH WAY TOP AND BOTTOM TO REQUIRED LIFTPIT LEVEL. DRILL AND EPOXY N16-200 CENTRAL TOSLAB TO WALLS ALL AROUND. LOCALLY PROVIDESLAB FOLD FOR LIFT PIT SUMP.
22 N28-150
ADDITION AL
22 N28-150
AD DITIONAL
22 N
28-1
50
AD
DIT
ION
AL
22 N28-150
ADDITIONAL
REINFORCEMENTMAT 'A' TYPICAL.
MAT 'A
'
TYPICALLY PROVIDE A 200H x 120WCONCRETE CORBEL TO SUPPORTEXTERNAL LEAF OF BRICKWORK MINIMUM2 COURSES BELOW GROUND LEVEL
MAT 'A
'
MAT 'A
'
MAT 'A
'
MAT 'A
'
MAT 'A
'
MAT 'A
'
MAT 'A
'
MAT 'A
'
MAT 'A
'
MAT 'A
'
MAT 'A
'
MAT 'A
'
MAT 'A
'
MAT 'A
'
MAT 'A
'
MAT 'A'
MAT 'A'
RW2
W11A
W11A
SF1
SF1
W2
W2
W2
WJ
WJ
WJ
WJ
WJ
WJ
WJ
WJ
WJ
WJ
WJ
WJ
WJ
WJ
WJ
WJ
WJ
WJ
WJ
W11A
STAIR 7
WE1
WE2
WE3
WE4
WE5
WE7
WE6
WE8
WJ
WE21
WE22
WE23
ST2
ST
2
ST2
W11A
W11A
W11A
TRENCH DRAIN
BASEMENT RAFT NOTES
1. FOR GENERAL NOTES REFER TO DRAWING S01- S02
2. ADOPT TYPICAL DETAILS UNLESS NOTED OTHERWISE
3. REFER TO ARCHITECTURAL DETAILS FOR FALLS & LEVELS
4.
6. DENOTES WET AREA SETDOWN ARE REQUIRED
8. DENOTES SLAB STEP
9 . DENOTES DOWELED MOVEMENT JOINT
12.
-86
DJ
B.C.J.
10.
11 .
DENOTES BRICK CONTROL JOINT VERTICAL
THROUGH OUT
5. ALL CONCRETE JOINTS AND CONCRETE POUR JOINTSTO HAVE WATER STOPS AS INDICATED ON THEDRAWINGS AS WELL AS THE ARCHITECRUALDRAWINGS. ALL REARGUARD WATERSTOPS TO BEWELDED JOINTS AND SHOP DRAWINGS SUBMITTED TOTHE SUPERINTENDENT FOR APPROVAL.
C.J.
M.J.
DENOTES CONSTRUCTION JOINT. 10 DAY
DELAY BETWEEN ADJACENT POURS
DENOTES SLAB MOVEMENT JOINT. 20mm
COMPRESSIBLE FILLER BETWEEN
SLAB INDICATED AS SHADED
7. DENOTES EXTENT OF 50mm CURBING
PROVIDE MINIMUM THICKNESS RAFT OF 450mm. RAFTCONCRETE TO BE AN S40 MIX WITH XYPEX ADMIX C-1000ADDITIVE, INCLUDING ALL RAFT PUMP PITS, LIFT PITS ANDRETAINING WALLS. PROVIDE N20-175 EACH WAY TOP ANDBOTTOM THROUGHOUT RAFT SLAB AND PROVIDEADDITIONAL BARS AS INDICATED ON PLAN. LAP BARS 1000TYPICAL. PROVIDE 2 N20 X 2000 LONG BARS AT ALL RE-ENTRANT CORNERS.
CAST-IN SERVICES
LOCASLISED THICKENINGS TO BE PROVIDED FOR CAST-INSERVICES INTO RAFT. PROVIDE MINIMUM 150 CONCRETE BELOWSERVICE. CRANK AND LAP REINFORCEMENT AS REQUIRED.
NDRAWING No.
PHA No.
DESIGNED
REDUCTION
DATESCALE @ B1
APPROVED
DRAWN
CHECKED0 25
REV.
THIS IS A CAD DRAWING - DO NOT AMEND MANUALLY
NO DATE AMENDMENT CHECKED
8 COLIN GROVE WEST PERTH WA 6005t: (08) 9322 6033 f: (08) 9324 1691e: [email protected]
Mechanical Consultant
Quantity Surveyor
Electrical Consultant
Hydraulic Consultant
Structural and Civil
Environmental Consultant
BCA Compliance
Mechanical Consultant
Hydraulic Consultant
Landscape Architect
Fire Consultant
BPA EngineeringGround Floor, 460 Roberts Road, Subiaco WA 6000Tel: (08) 93828008 Fax: (08) 93898374 [email protected]
Geoff Hesford EngineeringLevel 1/45 Market Street, Fremantle, WA 6160Mob. 0419 911 166/ 0410 976 571 [email protected]
ETC61 Loftus Street, Leederville WA 6006Tel: (08) 9328 5500 Fax: (08) 9328 5522 [email protected]
SEDGMAN CONSULTINGLevel 1, 202 Pier Street, Perth, WA 6000Tel: (08) 6255 0000 [email protected]
Gabriels Environmental DesignUNIT 3 2 Hardy Street, South Perth WA 6151Tel: (08) 9474 5966 Fax: (08) 9474 5977 [email protected]
ARUPLevel 7, Wellington Central, 836 Wellington Street, West Perth, WA 6005Tel: (08) 9328 5500 Fax: (08) 9328 5522 [email protected]
Ian Lush & AssociatesLevel 2, 2 GEORGE WIENCKE DRIVE, PERTH AIRPORT WA 6105Tel: (08) 9479 5170 Fax: (08) 94772259 [email protected]
Pullyblank Pty Ltd42 Solomon Stret, Fremantle, WA 6160Mob: 0413 056 836 [email protected]
COST PLANNING INTELLIGENCE8 Colin Grove, West Perth, WA 6005Mob: 0419 915 337 [email protected]
HeritageHOCKING HERITAGE STUDIO156 Onslow Road, Shenton Park WA 6008Tel: (08) 938 82810 [email protected]
ACEA
Civil And Structural Consultants
BPA Engineering
E-mail: [email protected]
460 Roberts Road Subiaco, Western Australia 6008
P.O. Box 1308 Subiaco,Facsimile: 61 8 9382 8006Telephone 61 8 9382 8008Western Australia 6008
BPA No. S01217 1As indicated
S10
JAV
BASEMENT FLOOR PLAN SHEET 1
LT
LT
S01217
FEB 2017
CONSTRUCTION
1 : 100
BASEMENT FLOOR PLAN SHEET 1
WALL SCHEDULE
TYPE DESCRIPTION
RW1 250 THICK CONCRETE RETAINING WALL
RW2 200 THICK CONCRETE RETAINING WALL
RW3 320 THICK DOUBLE BRICK CONCRETECAVITY RETAINING WALL
RW4 320 THICK DOUBLE BRICK CONCRETECAVITY RETAINING WALL
SW1 350 THICK BRICK SCREEN WALL
W1 250 THICK CONCRETE WALL
W1A 250 THICK CONCRETE WALL + 110THICK BRICK OUTER SKIN
W2 200 THICK CONCRETE WALL
W3 300 THICK CONCRETE WALL
W5 450 THICK CONCRETE WALL
W6A 100 HIGH x 92 WIDE CONCRETE BUND
W6B 200 HIGH x 200 WIDE CONCRETE BUND
W6C 150 HIGH x 150 WIDE CONCRETE BUND
W8 DOUBLE BRICK 320 CONC CAVITY
W9 190 THICK CORE FILLED BLOCK WALL
W10 90mm BLOCK WALL
W10A 190 THICK CORE FILLED BLOCK WALL +110 BRICK
W11A 230 DOUBLE BRICK
W11C 285 THICK DOUBLE BRICK WALL
W11E 285 BRICK VENEER
W11F 270 DOUBLE BRICK
W11G BRICK VENEER
W12A 110 THICK SINGLE LEAF BRICK
W12B 110 BRICK FIRE WALL
W12C 110 BRICK FIRE WALL
W13 140 THICK CORE FILLED BLOCK WALL
STRUCTURAL COLUMN SCHEDULE
TYPE DESCRIPTION
CC1 700x350 CONCRETE COLUMN
CC2 Ø500 CONCRETE COLUMN
CC3 500x550 CONCRETE COLUMN
CC4 350 x 600 CONCRETE COLUMN
CC5 400 x 600 CONCRETE COLUMN
CC7 600 x 300 CONCRETE COLUMN
CC8 300 x 300 CONCRETE COLUMN
CC9 300 x 900 CONCRETE COLUMN
SC1* 219.1x8.2 CHS (2HR FIRE RATED)
SC2 100x100x6 SHS
SC2* 100x100x6 SHS (2HR FIRE RATED)
SC3 89x89x6 SHS
SC4 150x150x5.0 SHS
SC5 150x100x4.0 RHS
SC6* 150x150x6.0 SHS (2HR FIRE RATED)
SC7 100x50x4.0 RHS
SC8 100x100x4.0 SHS TRUSS CONNECTOR
SC9 219.1 x 6.3 CHS
SC10 125x125x5.0 SHS
SC11 100x100x6.0 SHS
SC12 125x75x6.0 RHS
SC13 100x100x5.0 SHS
SC14 89x89x5.0 SHS
UA1 100x75x8 UA RWP BLOCKOUT ANGLEFIXED WITH M12 ANCHORS AT 300 C/C
FOOTING SCHEDULE
MARK DESCRIPTION REINFORCEMENT
PF1 2000 x 2000 x 400 DEEP N20 - 150 E.W. T&B
PF2 1200 x 1200 x 400 DEEPCONCRETE PAD FOOTING
N12 - 200 E.W. T&B
PF3 1400 x 1400 x 400CONCRETE PAD FOOTING
N16 - 200 E.W. T&B
SF1 500 WIDE x 443 DEEPSTRIP FOOTING
5L11TM BOTTOM
SF2 1200 WIDE x 400 DEEPSTRIP FOOTING
N12 - 300 E.W. T&B
ST1 500 WIDE x 172 DEEP SLABTHICKENING
5L11TM BOTTOM
ST2 2400W CONCRETE SLABTHICKENING
REFER DETAIL
1 08.01.17 ISSUED FOR CONSTRUCTION CJ
1
2
34
5
6
The blue lines show the block walls requested to be scanned to confirm that all cores had been filled.The numbers correspond with photos for each wall scanned, showing where voids were detected or not detected.
UP
VOID
VOID
17
15
13
14
16
11
12
GF H IE
9A B10 C D8
CC
1C
C1
CC
1
CC
1
CC
1
CC
1
CC
1
CC1
CC
1C
C1
CC
1
CC
1
W1A
W1A
W1A
W1A
W1
W1A
W1
W1
W9
W9
W9
W9
W2
W2
W2
W2
W9
W9
W1
W1
W9
W2W2
W1A
W9
W9
W9
W9
RW2
W9
CONCRETE ENCASED PUMPPACKAGE UNIT BY HYDRAULICCONSULTANTS
W2
W2
W9
W9
W1
W1
W1
W1B-A
S12
BB-N
S14
B-B
S12
STAIR 2
STAIR 5
B-D
S12
B-C
S12BB-P
S14
BB-L
S14
BB-H
S13
CC7
CC7
W1
SLAB LAID TO FALLS.MAINTAIN MIN 400mmSLAB THICKNESS
PLINTH SHOWN INDICATIVELY.REFER HYDRAULIC FOR PUMPLOCATION.
BB-F
S13
BB-J
S13
BB-K
S13
BB-G
S13
BB-M
S14
W11A
W9W9
W10
W2
W2
W2
W1A
W1A
W1A
W5 UNDER
W5 UNDER
W10
300
300
150
ET3
MASS CONCRETE LIFT PIT BASE FROM RAFT TOLIFT PIT LEVEL.
ALTERNATIVELY, PROVIDE COMPACTED SAND FILLAND PROVIDE A 250 THICK SLAB WITH N12-200EACH WAY TOP AND BOTTOM TO REQUIRED LIFTPIT LEVEL. DRILL AND EPOXY N16-200 CENTRAL TOSLAB TO WALLS ALL AROUND. LOCALLY PROVIDESLAB FOLD FOR LIFT PIT SUMP.
MAT 'A
'
450 THICK RAFT FOLDBETWEEN RAMP SLABAND MAIN RAFT
BB-R
S14
2S14
3S14
MAT 'A
'
MAT 'A
'
MAT 'A'
MAT 'A'
MAT 'A'
MAT 'A'
MAT 'A'
MAT 'A'
MAT 'A'
MAT 'A'
MAT 'A'
MAT 'A'
WJ
W2
W2
W2
WJ
WJ
WJ
WJ
WJ
WJ
WJ
WJ
WJ
WJ
WJ
WJ
WJ
WJ
WJ
WJ
W1
CC8
W11A
WE7
WE6
WE8
WE9
WE10
WE11
WE12
WE13
WE14
WE15
WE16
WE17
WE18
WE19
WE20
WE24
ST2
ST
2
ST
2
ST
2S
T2
TRENCH DRAIN
-100
RW2
RW2
RW2
W8 UNDER LANDING.W11A ABOVE LANDING.
CC
1
200 HIGH W6BUNDER W9
BASEMENT RAFT NOTES
1. FOR GENERAL NOTES REFER TO DRAWING S01- S02
2. ADOPT TYPICAL DETAILS UNLESS NOTED OTHERWISE
3. REFER TO ARCHITECTURAL DETAILS FOR FALLS & LEVELS
4.
6. DENOTES WET AREA SETDOWN ARE REQUIRED
8. DENOTES SLAB STEP
9 . DENOTES DOWELED MOVEMENT JOINT
12.
-86
DJ
B.C.J.
10.
11 .
DENOTES BRICK CONTROL JOINT VERTICAL
THROUGH OUT
5. ALL CONCRETE JOINTS AND CONCRETE POUR JOINTSTO HAVE WATER STOPS AS INDICATED ON THEDRAWINGS AS WELL AS THE ARCHITECRUALDRAWINGS. ALL REARGUARD WATERSTOPS TO BEWELDED JOINTS AND SHOP DRAWINGS SUBMITTED TOTHE SUPERINTENDENT FOR APPROVAL.
C.J.
M.J.
DENOTES CONSTRUCTION JOINT. 10 DAY
DELAY BETWEEN ADJACENT POURS
DENOTES SLAB MOVEMENT JOINT. 20mm
COMPRESSIBLE FILLER BETWEEN
SLAB INDICATED AS SHADED
7. DENOTES EXTENT OF 50mm CURBING
PROVIDE MINIMUM THICKNESS RAFT OF 450mm. RAFTCONCRETE TO BE AN S40 MIX WITH XYPEX ADMIX C-1000ADDITIVE, INCLUDING ALL RAFT PUMP PITS, LIFT PITS ANDRETAINING WALLS. PROVIDE N20-175 EACH WAY TOP ANDBOTTOM THROUGHOUT RAFT SLAB AND PROVIDEADDITIONAL BARS AS INDICATED ON PLAN. LAP BARS 1000TYPICAL. PROVIDE 2 N20 X 2000 LONG BARS AT ALL RE-ENTRANT CORNERS.
CAST-IN SERVICES
LOCASLISED THICKENINGS TO BE PROVIDED FOR CAST-INSERVICES INTO RAFT. PROVIDE MINIMUM 150 CONCRETE BELOWSERVICE. CRANK AND LAP REINFORCEMENT AS REQUIRED.
NDRAWING No.
PHA No.
DESIGNED
REDUCTION
DATESCALE @ B1
APPROVED
DRAWN
CHECKED0 25
REV.
THIS IS A CAD DRAWING - DO NOT AMEND MANUALLY
NO DATE AMENDMENT CHECKED
8 COLIN GROVE WEST PERTH WA 6005t: (08) 9322 6033 f: (08) 9324 1691e: [email protected]
Mechanical Consultant
Quantity Surveyor
Electrical Consultant
Hydraulic Consultant
Structural and Civil
Environmental Consultant
BCA Compliance
Mechanical Consultant
Hydraulic Consultant
Landscape Architect
Fire Consultant
BPA EngineeringGround Floor, 460 Roberts Road, Subiaco WA 6000Tel: (08) 93828008 Fax: (08) 93898374 [email protected]
Geoff Hesford EngineeringLevel 1/45 Market Street, Fremantle, WA 6160Mob. 0419 911 166/ 0410 976 571 [email protected]
ETC61 Loftus Street, Leederville WA 6006Tel: (08) 9328 5500 Fax: (08) 9328 5522 [email protected]
SEDGMAN CONSULTINGLevel 1, 202 Pier Street, Perth, WA 6000Tel: (08) 6255 0000 [email protected]
Gabriels Environmental DesignUNIT 3 2 Hardy Street, South Perth WA 6151Tel: (08) 9474 5966 Fax: (08) 9474 5977 [email protected]
ARUPLevel 7, Wellington Central, 836 Wellington Street, West Perth, WA 6005Tel: (08) 9328 5500 Fax: (08) 9328 5522 [email protected]
Ian Lush & AssociatesLevel 2, 2 GEORGE WIENCKE DRIVE, PERTH AIRPORT WA 6105Tel: (08) 9479 5170 Fax: (08) 94772259 [email protected]
Pullyblank Pty Ltd42 Solomon Stret, Fremantle, WA 6160Mob: 0413 056 836 [email protected]
COST PLANNING INTELLIGENCE8 Colin Grove, West Perth, WA 6005Mob: 0419 915 337 [email protected]
HeritageHOCKING HERITAGE STUDIO156 Onslow Road, Shenton Park WA 6008Tel: (08) 938 82810 [email protected]
ACEA
Civil And Structural Consultants
BPA Engineering
E-mail: [email protected]
460 Roberts Road Subiaco, Western Australia 6008
P.O. Box 1308 Subiaco,Facsimile: 61 8 9382 8006Telephone 61 8 9382 8008Western Australia 6008
BPA No. S01217 1As indicated
S11
JAV
BASEMENT FLOOR PLAN SHEET 2
LT
LT
S01217
FEB 2017
CONSTRUCTION
1 : 100
BASEMENT FLOOR PLAN SHEET 2
WALL SCHEDULE
TYPE DESCRIPTION
RW1 250 THICK CONCRETE RETAINING WALL
RW2 200 THICK CONCRETE RETAINING WALL
RW3 320 THICK DOUBLE BRICK CONCRETECAVITY RETAINING WALL
RW4 320 THICK DOUBLE BRICK CONCRETECAVITY RETAINING WALL
SW1 350 THICK BRICK SCREEN WALL
W1 250 THICK CONCRETE WALL
W1A 250 THICK CONCRETE WALL + 110THICK BRICK OUTER SKIN
W2 200 THICK CONCRETE WALL
W3 300 THICK CONCRETE WALL
W5 450 THICK CONCRETE WALL
W6A 100 HIGH x 92 WIDE CONCRETE BUND
W6B 200 HIGH x 200 WIDE CONCRETE BUND
W6C 150 HIGH x 150 WIDE CONCRETE BUND
W8 DOUBLE BRICK 320 CONC CAVITY
W9 190 THICK CORE FILLED BLOCK WALL
W10 90mm BLOCK WALL
W10A 190 THICK CORE FILLED BLOCK WALL +110 BRICK
W11A 230 DOUBLE BRICK
W11C 285 THICK DOUBLE BRICK WALL
W11E 285 BRICK VENEER
W11F 270 DOUBLE BRICK
W11G BRICK VENEER
W12A 110 THICK SINGLE LEAF BRICK
W12B 110 BRICK FIRE WALL
W12C 110 BRICK FIRE WALL
W13 140 THICK CORE FILLED BLOCK WALL
STRUCTURAL COLUMN SCHEDULE
TYPE DESCRIPTION
CC1 700x350 CONCRETE COLUMN
CC2 Ø500 CONCRETE COLUMN
CC3 500x550 CONCRETE COLUMN
CC4 350 x 600 CONCRETE COLUMN
CC5 400 x 600 CONCRETE COLUMN
CC7 600 x 300 CONCRETE COLUMN
CC8 300 x 300 CONCRETE COLUMN
CC9 300 x 900 CONCRETE COLUMN
SC1* 219.1x8.2 CHS (2HR FIRE RATED)
SC2 100x100x6 SHS
SC2* 100x100x6 SHS (2HR FIRE RATED)
SC3 89x89x6 SHS
SC4 150x150x5.0 SHS
SC5 150x100x4.0 RHS
SC6* 150x150x6.0 SHS (2HR FIRE RATED)
SC7 100x50x4.0 RHS
SC8 100x100x4.0 SHS TRUSS CONNECTOR
SC9 219.1 x 6.3 CHS
SC10 125x125x5.0 SHS
SC11 100x100x6.0 SHS
SC12 125x75x6.0 RHS
SC13 100x100x5.0 SHS
SC14 89x89x5.0 SHS
UA1 100x75x8 UA RWP BLOCKOUT ANGLEFIXED WITH M12 ANCHORS AT 300 C/C
FOOTING SCHEDULE
MARK DESCRIPTION REINFORCEMENT
PF1 2000 x 2000 x 400 DEEP N20 - 150 E.W. T&B
PF2 1200 x 1200 x 400 DEEPCONCRETE PAD FOOTING
N12 - 200 E.W. T&B
PF3 1400 x 1400 x 400CONCRETE PAD FOOTING
N16 - 200 E.W. T&B
SF1 500 WIDE x 443 DEEPSTRIP FOOTING
5L11TM BOTTOM
SF2 1200 WIDE x 400 DEEPSTRIP FOOTING
N12 - 300 E.W. T&B
ST1 500 WIDE x 172 DEEP SLABTHICKENING
5L11TM BOTTOM
ST2 2400W CONCRETE SLABTHICKENING
REFER DETAIL
1 08.01.17 ISSUED FOR CONSTRUCTION CJ
7 8
9
1011121314
15
16
17
The following 10 pages show photos of the walls scanned on the basement level.
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 1
Wall 2
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 3
Wall 4
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 5
Wall 5
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 6
Wall 6
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 7
Wall 8
No Voids Detected
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 9
Wall 10
No Voids Detected
No Voids Detected
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 11
Wall 12
No Voids Detected
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 13
Wall 14
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 15
Wall 16
No Voids Detected
No Voids Detected
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 17No Voids Detected
UPUPUP
UPUP
UPUP
UPUPUP
UPUPUP
UPUPUP
UPUP
UPUP
UPUPUP
UPUPUP11
GF H I LKJE
4
3
2
5
6
7
9
A
B
10
C
D
1
8
250
1-B11
1-B10
1-B9
1-B8
200
200
300
1-B5
1-B7
200
200 MIN
FALL1:100
300
200
CC
3
200
200
W2
W2
W2
W2
W2
W2
W2
W2
-250
300
W9
W9
CC
3
CC
1
200
W2
SC1*
SC1*
SC1*
250
250
CC
5C
C4
120 MIN.FIRE WALL
W9
SLAB JOINT
W9
W9
W9
STAIR
2
STAIR 1
STAIR
3
PF2PF2
PF2PF2
PF2
SC
2S
C2
SC
2
SC
2
SC
2
1-B4
-86
B-D
S12
B-C
S12
1-B
14
BB-P
S14
CB-L
S29
ST1
ST1S
T1
CB-J
S28
CB-B
S27
CB-E
S28
CB-C
S28
CB-M
S28
CB-P
S28
CB-A
S28
CB-D
S27
CB-H
S27
CB-K
S28
CB-N
S29
CB-F
S27
CB-R
S29
1-B3
DJ1
DJ1
W11C
W11C
W11C
W11C
W11C
W11C
W11C W9
W11C
W11C
W2
W11C
W11C
W11C
W9
W9
W9
W13
W11C
W11C
W9
W11C
W11C
W11C W11C
W2
W2
W2
W2
CC9
CC
9
SC6*
SC6*
SF
1
SF
1
SF1
CB-ZA
S27
W6C
W11C
W11C
SF1
SF1SF1
W11C
W11C
STAIR 4
SC6*
SC6*
SC6*
SC6*
SC6*
SC6*
SC6*
SC6*
SC6*
W12BUNDER
ET1
ZB
S28
VO
ID
VO
ID
VO
ID
TJTJEJTJ
TJ
VOID
SF
1
SF1
W11F
W11F
W9
ZC
S28
NOTE: INTERNAL WALLS NOT CALLED UP FORCLARITY, THEY ARE TO BE 110mm THICKBRICKWORK UNLESS NOTED OTHERWISE.
FOOTING AND GROUND SLAB NOTES
1. FOR GENERAL NOTES REFER TO DRAWING S01- S02
2. ADOPT TYPICAL DETAILS UNLESS NOTED OTHERWISE
3. REFER TO ARCHITECTURAL DETAILS FOR FALLS & LEVELS
4. U.N.O. SLABS ON GROUND TO BE 100mm THICK LAID OVER
WATERPROOF MEMBRANE ON CLEAN COMPACTED SAND
(COMPACTED TO 95% MDD).
SLAB REINFORCEMENT TO BE-
- INTERNAL SL62 MESH (TOP LAYER)
- EXTERNAL SL72 MESH (TOP LAYER)
6. DENOTES WET AREA SETDOWN AS REQUIRED
8. DENOTES SLAB STEP
9 . DENOTES DOWELED MOVEMENT JOINT
12.
13. DENOTES N16 -1500 LONG RE-ENTRANT BAR
FIXED TO BOTTOM OF SLAB REINFORCING MESHTO ALL RE-ENTRANT CORNERS.
-86
DJ
B.C.J.
RE
10.
11 .
DENOTES BRICK CONTROL JOINT VERTICAL
THROUGH OUT
5. REFER TO GENERAL NOTES S01-S02 FOR MASONRYDETAILS AND REQUIREMENTS. PROVIDE ACOUSTIC WALLTIES TO CAVITY WALLS DIVIDING UNITS, LOBBY, FOYER,COMMON ROOMS AND AS REQUIRED BY ARCHITECT.INSTALL IN ACCORDANCE WITH ARCHITECT AND B.C.A.REQUIREMENTS. PROVIDE TIES AT 600mm HORIZONTALCENTRES AND 400mm VERTICALLY MANUFACTURESSPECIFICATION.
C.J.
M.J.
DENOTES CONSTRUCTION JOINT. 10 DAY
DELAY BETWEEN ADJACENT POURS
DENOTES SLAB MOVEMENT JOINT. 20mm
COMPRESSIBLE FILLER BETWEEN
SLAB INDICATED AS SHADED
7. DENOTES EXTENT OF 40mm MATWELL SETDOWN
SUSPENDED SLAB GENERAL NOTES
DENOTES COLUMN AND LOAD BEARING WALLSUNDER, REFER TYPICAL CONCRETE DETAILS
DENOTES COLUMN ABOVE, REFER DETAILDRAWINGS FOR DETAILS OF COLUMNS ANDWALLS ABOVE
CC
?
DENOTES CONSTRUCTION JOINT. 10DAY DELAY BETWEEN ADJACENT POURS
C.J.
200
MJ
B.C.J.
1. FOR GENERAL NOTES REFER TO DRAWING S001- S002
2. ADOPT TYPICAL DETAILS UNLESS NOTED OTHERWISE
3. REFER TO ARCHITECTURAL DETAILS FOR FALLS & LEVELS
4. SLAB THICKNESS NOTATION
DENOTES MINIMUM STRUCTURAL THICKNESS,
NOT INCLUDING FALLS.
5. PROVIDE BOND BREAKER TO ALL LOAD BEARINGSURFACES. PROVIDE COMPRESSIBLE JOINT TO NON LOADBEARING SURFACES. REFER TO GENERAL NOTESDRAWING S01-S02. INSTALL BOND BREAKER INACCORDANCE WITH SUPPLIERS SPECIFICATIONS.
6. REFER TO GENERAL NOTES S01-S02 FOR MASONRYDETAILS & REQUIREMENTS. PROVIDE ACOUSTIC WALL TIESTO PARTITION CAVITY WALLS AS PER ARCHITECTURAL &B.C.A REQUIREMENTS.
7.
8.
DENOTES 40mm WET AREA SETDOWN9.
DENOTES SLAB STEP10.
11.
12.
DENOTES MOVEMENT JOINT -BETWEEN SLAB AND WALLS
DENOTES BRICK CONTROLJOINT - VERTICALLY UP WALL
13.PROVIDE ACOUSTIC INSULATION TO ALL 172SLABS OR THINNER, AS REQUIRED TO BCA REQUIREMENTS.
14.
-86
15.CONTRACTOR TO CO-ORDINATE CAST IN SERVICES PIPESAND DISPLACE REINFORCEMENT AS REQUIRED TO SUIT.
DENOTES FREEZER/COOLROOM SETDOWN10.
DENOTES 65mm KITCHEN SETDOWN9.
NDRAWING No.
PHA No.
DESIGNED
REDUCTION
DATESCALE @ B1
APPROVED
DRAWN
CHECKED0 25
REV.
THIS IS A CAD DRAWING - DO NOT AMEND MANUALLY
NO DATE AMENDMENT CHECKED
8 COLIN GROVE WEST PERTH WA 6005t: (08) 9322 6033 f: (08) 9324 1691e: [email protected]
Mechanical Consultant
Quantity Surveyor
Electrical Consultant
Hydraulic Consultant
Structural and Civil
Environmental Consultant
BCA Compliance
Mechanical Consultant
Hydraulic Consultant
Landscape Architect
Fire Consultant
BPA EngineeringGround Floor, 460 Roberts Road, Subiaco WA 6000Tel: (08) 93828008 Fax: (08) 93898374 [email protected]
Geoff Hesford EngineeringLevel 1/45 Market Street, Fremantle, WA 6160Mob. 0419 911 166/ 0410 976 571 [email protected]
ETC61 Loftus Street, Leederville WA 6006Tel: (08) 9328 5500 Fax: (08) 9328 5522 [email protected]
SEDGMAN CONSULTINGLevel 1, 202 Pier Street, Perth, WA 6000Tel: (08) 6255 0000 [email protected]
Gabriels Environmental DesignUNIT 3 2 Hardy Street, South Perth WA 6151Tel: (08) 9474 5966 Fax: (08) 9474 5977 [email protected]
ARUPLevel 7, Wellington Central, 836 Wellington Street, West Perth, WA 6005Tel: (08) 9328 5500 Fax: (08) 9328 5522 [email protected]
Ian Lush & AssociatesLevel 2, 2 GEORGE WIENCKE DRIVE, PERTH AIRPORT WA 6105Tel: (08) 9479 5170 Fax: (08) 94772259 [email protected]
Pullyblank Pty Ltd42 Solomon Stret, Fremantle, WA 6160Mob: 0413 056 836 [email protected]
COST PLANNING INTELLIGENCE8 Colin Grove, West Perth, WA 6005Mob: 0419 915 337 [email protected]
HeritageHOCKING HERITAGE STUDIO156 Onslow Road, Shenton Park WA 6008Tel: (08) 938 82810 [email protected]
ACEA
Civil And Structural Consultants
BPA Engineering
E-mail: [email protected]
460 Roberts Road Subiaco, Western Australia 6008
P.O. Box 1308 Subiaco,Facsimile: 61 8 9382 8006Telephone 61 8 9382 8008Western Australia 6008
BPA No. S01217 2As indicated
S20
JAV
GROUND FLOOR PLAN SHEET 1
LT
LT
1557
FEB 2017
CONSTRUCTION
1 : 100
GROUND FLOOR PLAN SHEET 1
GROUND FLOOR CONCRETE BEAM SCHEDULE
TYPE DESCRIPTION
1-B1 2400 WIDE x 550 DEEP CONCRETE TAPER BEAM REFERDETAIL
1-B2 2400 WIDE x 700 DEEP CONCRETE TAPER BEAM REFERDETAIL
1-B3 2400 WIDE x 700 DEEP CONCRETE TAPER BEAM REFERDETAIL
1-B4 2400 WIDE x 550 DEEP CONCRETE TAPER BEAM REFERDETAIL
1-B5 300 WIDE x 1450 DEEP CONCRETE BEAM
1-B7 300 WIDE x 1450 DEEP CONCRETE BEAM
1-B8 600 WIDE x 500 DEEP CONCRETE BEAM
1-B9 600 WIDE x 500 DEEP CONCRETE BEAM
1-B10 2400 WIDE x 550 DEEP CONCRETE TAPER BEAM REFERDETAIL
1-B11 1200 WIDE x 550 DEEP CONCRETE BEAM
1-B12 2400 WIDE x 550 DEEP CONCRETE BEAM
1-B13 2400 WIDE x 550 DEEP CONCRETE TAPER BEAM REFERDETAIL
1-B14 250 WIDE x 730 DEEP CONCRETE BEAM
1-B15 900 X 450 DEEP CONCRETE BEAM
WALL SCHEDULE
TYPE DESCRIPTION
RW1 250 THICK CONCRETE RETAINING WALL
RW2 200 THICK CONCRETE RETAINING WALL
RW3 320 THICK DOUBLE BRICK CONCRETE CAVITY RETAININGWALL
RW4 320 THICK DOUBLE BRICK CONCRETE CAVITY RETAININGWALL
SW1 200mm THICK PRECAST CONCRETE PANEL WITHARTWORK TO ARCH. REQUIREMENTS. MINIMUM PANELTHICKNESS 190mm.
SW2 200mm THICK PRECAST CONCRETE PANEL WITHARTWORK TO ARCH. REQUIREMENTS. MINIMUM PANELTHICKNESS 190mm.
W1 250 THICK CONCRETE WALL
W1A 250 THICK CONCRETE WALL + 110 THICK BRICK OUTERSKIN
W2 200 THICK CONCRETE WALL
W3 300 THICK CONCRETE WALL
W5 450 THICK CONCRETE WALL
W6A 100 HIGH x 92 WIDE CONCRETE BUND
W6B 200 HIGH x 200 WIDE CONCRETE BUND
W6C 150 HIGH x 150 WIDE CONCRETE BUND
W8 DOUBLE BRICK 320 CONC CAVITY
W9 190 THICK CORE FILLED BLOCK WALL
W10 90mm BLOCK WALL
W10A 190 THICK CORE FILLED BLOCK WALL + 110 BRICK
W11A 230 DOUBLE BRICK
W11C 285 THICK DOUBLE BRICK WALL
W11E 285 BRICK VENEER
W11F 270 DOUBLE BRICK
W11G BRICK VENEER
W12A 110 THICK SINGLE LEAF BRICK
W12B 110 BRICK FIRE WALL
W12C 110 BRICK FIRE WALL
W13 140 THICK CORE FILLED BLOCK WALL
FOOTING SCHEDULE
MARK DESCRIPTION REINFORCEMENT
EP1 800 x 600 x 300 DEEP MASSCONCRETE ERECTION PAD, REFERSF3 DETAIL.
N/A
PF1 2000 x 2000 x 400 DEEP N20 - 150 E.W. T&B
PF2 1200 x 1200 x 400 DEEP CONCRETEPAD FOOTING
N12 - 200 E.W. T&B
PF3 1400 x 1400 x 400 CONCRETE PADFOOTING
N16 - 200 E.W. T&B
SF1 500 WIDE x 443 DEEP STRIP FOOTING 5L11TM BOTTOM
SF2 1200 WIDE x 400 DEEP STRIPFOOTING
N12 - 300 E.W. T&B
SF3 1200 WIDE x 300 DEEP STRIPFOOTING
REFER DETAIL
SF4 800 WIDE x 300 DEEP STRIP FOOTING REFER DETAIL
ST1 500 WIDE x 172 DEEP SLABTHICKENING
5L11TM BOTTOM
ST2 2400W CONCRETE SLAB THICKENING REFER DETAIL
STRUCTURAL COLUMN SCHEDULE
TYPE DESCRIPTION
CC1 700x350 CONCRETE COLUMN
CC2 Ø500 CONCRETE COLUMN
CC3 500x550 CONCRETE COLUMN
CC4 350 x 600 CONCRETE COLUMN
CC5 400 x 600 CONCRETE COLUMN
CC7 600 x 300 CONCRETE COLUMN
CC8 300 x 300 CONCRETE COLUMN
CC9 300 x 900 CONCRETE COLUMN
SC1* 219.1x8.2 CHS (2HR FIRE RATED)
SC2 100x100x6 SHS
SC2* 100x100x6 SHS (2HR FIRE RATED)
SC3 89x89x6 SHS
SC4 150x150x5.0 SHS
SC5 150x100x4.0 RHS
SC6* 150x150x6.0 SHS (2HR FIRE RATED)
SC7 100x50x4.0 RHS
SC8 100x100x4.0 SHS TRUSS CONNECTOR
SC9 219.1 x 6.3 CHS
SC10 125x125x5.0 SHS
SC11 100x100x6.0 SHS
SC12 125x75x6.0 RHS
SC13 100x100x5.0 SHS
SC14 89x89x5.0 SHS
UA1 100x75x8 UA RWP BLOCKOUT ANGLE FIXED WITH M12ANCHORS AT 300 C/C
SLAB EDGE SCHEDULE
MARK DESCRIPTION
ET1 257 D x 500 W SLAB EDGE THICKENING
ET3 300 D x 500 W SLAB EDGE THICKENING
0 27.10.17 ISSUED FOR TENDER CJ
1 08.01.18 ISSUED FOR CONSTRUCTION CJ
2 23.08.18 ISSUED FOR CONSTRUCTION CJ
2
2
2
12
3
4
5 6
78
9
10
11
The blue lines show the block walls requested to be scanned to confirm that all cores had been filled.Where a wall is shown with an “ ”, this shows where the wall had not yet been built or had not yet been filled.The numbers correspond with photos for each wall scanned, showing where voids were detected or not detected.
UPUPUP
UPUPUP
UPUPUP
UPUP
UPUP
UPUPUP
UPUPUP
UPUPUP
UPUP
UPUP
17
15
13
14
16
11
12
GF H I LKJE
9A B10 C D8
1-B11
1-B
1
CC
3
W2
W2
W2
W2
W2
W2
W2
W2
-250
300
W9
W9
W9
W9
CC
3
CC
1
W9
W9
400
200
200
200
200
300
W9
250
300
W2
SC1*
SC1*
SC1*
SC1*
250
250
250
CC
5C
C4
120 MIN.FIRE WALL
FIRE WALL
W9
W9
W9 W11C
RW4
SF
1E
T1
DJ1
DJ1
DJ1
DJ1
DJ1
DJ1
DJ1
DJ1
DJ1
W10A
1-B
2
BB-N
S14
CB-X
S29
STAIR
2
STAIR 6STAIR 5
1800
1-B
13
-86
B-D
S12
B-C
S12
CB-Q
S27
1-B
14
BB-L
S14
CB-L
S29
SF1
SF1
SF
1
SF
1
ST
1
ST
1
ST
1
ST
1
ST
1
ST
1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST
1S
T1
ST
1S
T1
ST
1
ST
1
ST
1
ST
1
ST
1
ST
1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
9117
250 THICK TANK LID WITHAUSTRAL DECK FORMWORK WITHTEMPORARY SUPPORT BEAMS.
CB-Z
S28
CB-W
S28
CB-Y
S28
CB-S
S29
CB-M
S28
CB-P
S28
CB-N
S29
CB-T
S29
CB-U
S29
CB-V
S28
BB-M
S14
CB-R
S29
1-B3
SC6* SC
6*
SC6*
SC6*
SC6*SC
6*
SLAB JOINT
DJ1
DJ1
DJ1 DJ1
W11C
W11C
W2
W2
W2
W2
W2
CC9
CC
9
W11C
W11C
W11C
W11C
CC
7
CC
7
W13
W11C
W11C
W11F
W11F
W11C
W11C
W11C
UN
DER
CC
8
W11C
W11C
W11C
W11C
W11C
SC6*
SC6*
SC6* SC
6*
SC6*
SC6*
SC3
SC3
SC6*
SC6*
SC6*
SC6*
SC
9
SC
9
SC8SC
8
SC
8SC
8
SC
8
SC
8
SC8SC
8
SC
8
SC
8
SC
8
SC
8
SC
8
SC
8
SC8
SC8
SC
8
SC
8
SC
8
SC
8
SC
8
SC
8
PF1
PF1
PF3PF3
PF3PF3
BB-R
S14
1-B
15
SF
1
SF
1SW2
SW1
SW2 SW1
SW1
SW2
SW1
1
S56
2
S56
PF3
PF3PF3
PF3PF3
PF3PF3
PF3PF3
PF3
PF3
6
S56
W6C
W11C
W11C
SF1SF1
SC6*
SC1*
W12BUNDER
ET1
ET1
-86
ST
1
RW3BELOW
RW3BELOW
RW4BELOW
RW4BELOW
ZB
S28
10
S56
SC6*
SC6*
ST
1
VO
ID
VO
ID
VO
ID
VOID
SF
1
SF1
SF
1
W11F
W11F
2
S63
3
S63
7
S63
6
S63
SF
3
EP1
EP1
EP1
EP1
EP1
EP1
SF
4SF
3
SF
3
SF
4
EP1
EP1
EP1EP1
SF
3
SF
4
EP1EP1
EP1
EP1
ZC
S28
NOTE: INTERNAL WALLS NOT CALLED UP FORCLARITY, THEY ARE TO BE 110mm THICKBRICKWORK UNLESS NOTED OTHERWISE.
FOOTING AND GROUND SLAB NOTES
1. FOR GENERAL NOTES REFER TO DRAWING S01- S02
2. ADOPT TYPICAL DETAILS UNLESS NOTED OTHERWISE
3. REFER TO ARCHITECTURAL DETAILS FOR FALLS & LEVELS
4. U.N.O. SLABS ON GROUND TO BE 100mm THICK LAID OVER
WATERPROOF MEMBRANE ON CLEAN COMPACTED SAND
(COMPACTED TO 95% MDD).
SLAB REINFORCEMENT TO BE-
- INTERNAL SL62 MESH (TOP LAYER)
- EXTERNAL SL72 MESH (TOP LAYER)
6. DENOTES WET AREA SETDOWN AS REQUIRED
8. DENOTES SLAB STEP
9 . DENOTES DOWELED MOVEMENT JOINT
12.
13. DENOTES N16 -1500 LONG RE-ENTRANT BAR
FIXED TO BOTTOM OF SLAB REINFORCING MESHTO ALL RE-ENTRANT CORNERS.
-86
DJ
B.C.J.
RE
10.
11 .
DENOTES BRICK CONTROL JOINT VERTICAL
THROUGH OUT
5. REFER TO GENERAL NOTES S01-S02 FOR MASONRYDETAILS AND REQUIREMENTS. PROVIDE ACOUSTIC WALLTIES TO CAVITY WALLS DIVIDING UNITS, LOBBY, FOYER,COMMON ROOMS AND AS REQUIRED BY ARCHITECT.INSTALL IN ACCORDANCE WITH ARCHITECT AND B.C.A.REQUIREMENTS. PROVIDE TIES AT 600mm HORIZONTALCENTRES AND 400mm VERTICALLY MANUFACTURESSPECIFICATION.
C.J.
M.J.
DENOTES CONSTRUCTION JOINT. 10 DAY
DELAY BETWEEN ADJACENT POURS
DENOTES SLAB MOVEMENT JOINT. 20mm
COMPRESSIBLE FILLER BETWEEN
SLAB INDICATED AS SHADED
7. DENOTES EXTENT OF 40mm MATWELL SETDOWN
SUSPENDED SLAB GENERAL NOTES
DENOTES COLUMN AND LOAD BEARING WALLSUNDER, REFER TYPICAL CONCRETE DETAILS
DENOTES COLUMN ABOVE, REFER DETAILDRAWINGS FOR DETAILS OF COLUMNS ANDWALLS ABOVE
CC
?
DENOTES CONSTRUCTION JOINT. 10DAY DELAY BETWEEN ADJACENT POURS
C.J.
200
MJ
B.C.J.
1. FOR GENERAL NOTES REFER TO DRAWING S001- S002
2. ADOPT TYPICAL DETAILS UNLESS NOTED OTHERWISE
3. REFER TO ARCHITECTURAL DETAILS FOR FALLS & LEVELS
4. SLAB THICKNESS NOTATION
DENOTES MINIMUM STRUCTURAL THICKNESS,
NOT INCLUDING FALLS.
5. PROVIDE BOND BREAKER TO ALL LOAD BEARINGSURFACES. PROVIDE COMPRESSIBLE JOINT TO NON LOADBEARING SURFACES. REFER TO GENERAL NOTESDRAWING S01-S02. INSTALL BOND BREAKER INACCORDANCE WITH SUPPLIERS SPECIFICATIONS.
6. REFER TO GENERAL NOTES S01-S02 FOR MASONRYDETAILS & REQUIREMENTS. PROVIDE ACOUSTIC WALL TIESTO PARTITION CAVITY WALLS AS PER ARCHITECTURAL &B.C.A REQUIREMENTS.
7.
8.
DENOTES 40mm WET AREA SETDOWN9.
DENOTES SLAB STEP10.
11.
12.
DENOTES MOVEMENT JOINT -BETWEEN SLAB AND WALLS
DENOTES BRICK CONTROLJOINT - VERTICALLY UP WALL
13.PROVIDE ACOUSTIC INSULATION TO ALL 172SLABS OR THINNER, AS REQUIRED TO BCA REQUIREMENTS.
14.
-86
15.CONTRACTOR TO CO-ORDINATE CAST IN SERVICES PIPESAND DISPLACE REINFORCEMENT AS REQUIRED TO SUIT.
DENOTES FREEZER/COOLROOM SETDOWN10.
DENOTES 65mm KITCHEN SETDOWN9.
NDRAWING No.
PHA No.
DESIGNED
REDUCTION
DATESCALE @ B1
APPROVED
DRAWN
CHECKED0 25
REV.
THIS IS A CAD DRAWING - DO NOT AMEND MANUALLY
NO DATE AMENDMENT CHECKED
8 COLIN GROVE WEST PERTH WA 6005t: (08) 9322 6033 f: (08) 9324 1691e: [email protected]
Mechanical Consultant
Quantity Surveyor
Electrical Consultant
Hydraulic Consultant
Structural and Civil
Environmental Consultant
BCA Compliance
Mechanical Consultant
Hydraulic Consultant
Landscape Architect
Fire Consultant
BPA EngineeringGround Floor, 460 Roberts Road, Subiaco WA 6000Tel: (08) 93828008 Fax: (08) 93898374 [email protected]
Geoff Hesford EngineeringLevel 1/45 Market Street, Fremantle, WA 6160Mob. 0419 911 166/ 0410 976 571 [email protected]
ETC61 Loftus Street, Leederville WA 6006Tel: (08) 9328 5500 Fax: (08) 9328 5522 [email protected]
SEDGMAN CONSULTINGLevel 1, 202 Pier Street, Perth, WA 6000Tel: (08) 6255 0000 [email protected]
Gabriels Environmental DesignUNIT 3 2 Hardy Street, South Perth WA 6151Tel: (08) 9474 5966 Fax: (08) 9474 5977 [email protected]
ARUPLevel 7, Wellington Central, 836 Wellington Street, West Perth, WA 6005Tel: (08) 9328 5500 Fax: (08) 9328 5522 [email protected]
Ian Lush & AssociatesLevel 2, 2 GEORGE WIENCKE DRIVE, PERTH AIRPORT WA 6105Tel: (08) 9479 5170 Fax: (08) 94772259 [email protected]
Pullyblank Pty Ltd42 Solomon Stret, Fremantle, WA 6160Mob: 0413 056 836 [email protected]
COST PLANNING INTELLIGENCE8 Colin Grove, West Perth, WA 6005Mob: 0419 915 337 [email protected]
HeritageHOCKING HERITAGE STUDIO156 Onslow Road, Shenton Park WA 6008Tel: (08) 938 82810 [email protected]
ACEA
Civil And Structural Consultants
BPA Engineering
E-mail: [email protected]
460 Roberts Road Subiaco, Western Australia 6008
P.O. Box 1308 Subiaco,Facsimile: 61 8 9382 8006Telephone 61 8 9382 8008Western Australia 6008
BPA No. S01217 2As indicated
S21
JAV
GROUND FLOOR PLAN SHEET 2
LT
LT
\
1557
FEB 2017
CONSTRUCTION
1 : 100
GROUND FLOOR PLAN SHEET 2
GROUND FLOOR CONCRETE BEAM SCHEDULE
TYPE DESCRIPTION
1-B1 2400 WIDE x 550 DEEP CONCRETE TAPER BEAM REFERDETAIL
1-B2 2400 WIDE x 700 DEEP CONCRETE TAPER BEAM REFERDETAIL
1-B3 2400 WIDE x 700 DEEP CONCRETE TAPER BEAM REFERDETAIL
1-B4 2400 WIDE x 550 DEEP CONCRETE TAPER BEAM REFERDETAIL
1-B5 300 WIDE x 1450 DEEP CONCRETE BEAM
1-B7 300 WIDE x 1450 DEEP CONCRETE BEAM
1-B8 600 WIDE x 500 DEEP CONCRETE BEAM
1-B9 600 WIDE x 500 DEEP CONCRETE BEAM
1-B10 2400 WIDE x 550 DEEP CONCRETE TAPER BEAM REFERDETAIL
1-B11 1200 WIDE x 550 DEEP CONCRETE BEAM
1-B12 2400 WIDE x 550 DEEP CONCRETE BEAM
1-B13 2400 WIDE x 550 DEEP CONCRETE TAPER BEAM REFERDETAIL
1-B14 250 WIDE x 730 DEEP CONCRETE BEAM
1-B15 900 X 450 DEEP CONCRETE BEAM
WALL SCHEDULE
TYPE DESCRIPTION
RW1 250 THICK CONCRETE RETAINING WALL
RW2 200 THICK CONCRETE RETAINING WALL
RW3 320 THICK DOUBLE BRICK CONCRETE CAVITY RETAININGWALL
RW4 320 THICK DOUBLE BRICK CONCRETE CAVITY RETAININGWALL
SW1 200mm THICK PRECAST CONCRETE PANEL WITHARTWORK TO ARCH. REQUIREMENTS. MINIMUM PANELTHICKNESS 190mm.
SW2 200mm THICK PRECAST CONCRETE PANEL WITHARTWORK TO ARCH. REQUIREMENTS. MINIMUM PANELTHICKNESS 190mm.
W1 250 THICK CONCRETE WALL
W1A 250 THICK CONCRETE WALL + 110 THICK BRICK OUTERSKIN
W2 200 THICK CONCRETE WALL
W3 300 THICK CONCRETE WALL
W5 450 THICK CONCRETE WALL
W6A 100 HIGH x 92 WIDE CONCRETE BUND
W6B 200 HIGH x 200 WIDE CONCRETE BUND
W6C 150 HIGH x 150 WIDE CONCRETE BUND
W8 DOUBLE BRICK 320 CONC CAVITY
W9 190 THICK CORE FILLED BLOCK WALL
W10 90mm BLOCK WALL
W10A 190 THICK CORE FILLED BLOCK WALL + 110 BRICK
W11A 230 DOUBLE BRICK
W11C 285 THICK DOUBLE BRICK WALL
W11E 285 BRICK VENEER
W11F 270 DOUBLE BRICK
W11G BRICK VENEER
W12A 110 THICK SINGLE LEAF BRICK
W12B 110 BRICK FIRE WALL
W12C 110 BRICK FIRE WALL
W13 140 THICK CORE FILLED BLOCK WALL
FOOTING SCHEDULE
MARK DESCRIPTION REINFORCEMENT
EP1 800 x 600 x 300 DEEP MASSCONCRETE ERECTION PAD, REFERSF3 DETAIL.
N/A
PF1 2000 x 2000 x 400 DEEP N20 - 150 E.W. T&B
PF2 1200 x 1200 x 400 DEEP CONCRETEPAD FOOTING
N12 - 200 E.W. T&B
PF3 1400 x 1400 x 400 CONCRETE PADFOOTING
N16 - 200 E.W. T&B
SF1 500 WIDE x 443 DEEP STRIP FOOTING 5L11TM BOTTOM
SF2 1200 WIDE x 400 DEEP STRIPFOOTING
N12 - 300 E.W. T&B
SF3 1200 WIDE x 300 DEEP STRIPFOOTING
REFER DETAIL
SF4 800 WIDE x 300 DEEP STRIP FOOTING REFER DETAIL
ST1 500 WIDE x 172 DEEP SLABTHICKENING
5L11TM BOTTOM
ST2 2400W CONCRETE SLAB THICKENING REFER DETAIL
STRUCTURAL COLUMN SCHEDULE
TYPE DESCRIPTION
CC1 700x350 CONCRETE COLUMN
CC2 Ø500 CONCRETE COLUMN
CC3 500x550 CONCRETE COLUMN
CC4 350 x 600 CONCRETE COLUMN
CC5 400 x 600 CONCRETE COLUMN
CC7 600 x 300 CONCRETE COLUMN
CC8 300 x 300 CONCRETE COLUMN
CC9 300 x 900 CONCRETE COLUMN
SC1* 219.1x8.2 CHS (2HR FIRE RATED)
SC2 100x100x6 SHS
SC2* 100x100x6 SHS (2HR FIRE RATED)
SC3 89x89x6 SHS
SC4 150x150x5.0 SHS
SC5 150x100x4.0 RHS
SC6* 150x150x6.0 SHS (2HR FIRE RATED)
SC7 100x50x4.0 RHS
SC8 100x100x4.0 SHS TRUSS CONNECTOR
SC9 219.1 x 6.3 CHS
SC10 125x125x5.0 SHS
SC11 100x100x6.0 SHS
SC12 125x75x6.0 RHS
SC13 100x100x5.0 SHS
SC14 89x89x5.0 SHS
UA1 100x75x8 UA RWP BLOCKOUT ANGLE FIXED WITH M12ANCHORS AT 300 C/C
SLAB EDGE SCHEDULE
MARK DESCRIPTION
ET1 257 D x 500 W SLAB EDGE THICKENING
ET3 300 D x 500 W SLAB EDGE THICKENING
0 27.10.17 ISSUED FOR TENDER CJ
1 08.01.18 ISSUED FOR CONSTRUCTION CJ
2 23.08.18 ISSUED FOR CONSTRUCTION CJ
2
2
2
2
2
2
2
10
11
12
13
14
The following 8 pages show photos of the walls scanned on the ground floor.
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 1
Wall 2No Voids Detected
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 2
Wall 3
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 3
Wall 4
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 5
Wall 6
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 7
Wall 8
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 9
Wall 10No Voids Detected
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 11
Wall 12
No Voids Detected
Part of the wall had not yet been filled, this was not marked as voids
No Voids Detected
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 13
Wall 14Part of the wall had not yet been filled, this was not marked as voids
No Voids Detected
UPUPUP
UPUP
UPUPUP
UPUP
11
GF H I LKJE
4
3
2
5
6
7
9
A
B
10
C
D
1
8
237
257
SLAB JOINT
237
237
257
CC
5
CC3
CC
1
SC6*
SC2*
SC6*
SC6*
SC2*
SC2*
SC2*
SC2*
SC2
SC2*
SC2*
SC2
SC2*
SC6*
SC2*
SC
2
SC
3
W2
W2W2
W2
W2
W2
W2
W2
W9
W9
W9
W2
SC6*
SC6*
SC6*
CC4
SC2*
SC2
SC2
SC2*
SC2*
SC2*
SC2*
SC2*
SC2*
SC2*
SC2*
SC2*
SC2*
SC2*
SC2*
SC2*
SC2*
SC3
SC2*
SC2*
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC6*
SC2
STAIR 1
STAIR
2
STAIR
3
VOID
2-B
12
SC6*
3-A
S59
2-B6
2-B9
2-B8
2-B
7 257
257
2-B1
2-B2
2-B32-B4
2-B5
W13
W9
W9
W9
W9
W9
W9
W2
CC9
CC9
W11C W11C
W11E
W2
W2
W2
W2
SC2*
SC3
SC2*
SC2*
SC3
SC3
SC2*
SC3
SC3
SC6* SC
6*
SC3
SC2*
SC3
SC3
SC3
SC3
W9
W11E
3-B
S59
3-C
S59
3-D
S59
2-DP1
2-DP1
SC2*
SC2*
SC2*
SC2*
SC6*
SC6*
SC6*
2-B13
SB9
SB
9
SB
9
W11E
13
S37
14
S37
15
S37
16
S37
17
S37
18
S37
UNDER
SC1*
UNDERSC
1*
SC2*
SC2*
SC2*
SC2*
W12B
SS
U1
SSU
1
SSU
2
SSU
1
SSU
1
SSU
2
SSU
1
SSU
1
SSU1
SSU
1
SSU
1
SSU
1
SSU
2
SSU
1
VO
ID VO
ID
VO
ID
VO
ID
VO
ID
VO
ID
VOID
VOID
VOID
VOID
SB9
P1
P1
SB9
VOID
VO
ID
W11E
SC2*
W11G
W11G
CJ1
CJ1
SUSPENDED SLAB GENERAL NOTES
DENOTES COLUMN AND LOAD BEARING WALLSUNDER, REFER TYPICAL CONCRETE DETAILS
DENOTES COLUMN ABOVE, REFER DETAILDRAWINGS FOR DETAILS OF COLUMNS ANDWALLS ABOVE
CC?
DENOTES CONSTRUCTION JOINT. 10DAY DELAY BETWEEN ADJACENT POURS
C.J.
200
MJ
B.C.J.
1. FOR GENERAL NOTES REFER TO DRAWING S001- S002
2. ADOPT TYPICAL DETAILS UNLESS NOTED OTHERWISE
3. REFER TO ARCHITECTURAL DETAILS FOR FALLS & LEVELS
4. SLAB THICKNESS NOTATION
DENOTES MINIMUM STRUCTURAL THICKNESS,
NOT INCLUDING FALLS.
5. PROVIDE BOND BREAKER TO ALL LOAD BEARINGSURFACES. PROVIDE COMPRESSIBLE JOINT TO NON LOADBEARING SURFACES. REFER TO GENERAL NOTESDRAWING S01-S02. INSTALL BOND BREAKER INACCORDANCE WITH SUPPLIERS SPECIFICATIONS.
6. REFER TO GENERAL NOTES S01-S02 FOR MASONRYDETAILS & REQUIREMENTS. PROVIDE ACOUSTIC WALL TIESTO PARTITION CAVITY WALLS AS PER ARCHITECTURAL &B.C.A REQUIREMENTS.
7.
8.
DENOTES 40mm WET AREA SETDOWN9.
DENOTES SLAB STEP10.
11.
12.
DENOTES MOVEMENT JOINT -BETWEEN SLAB AND WALLS
DENOTES BRICK CONTROLJOINT - VERTICALLY UP WALL
13.PROVIDE ACOUSTIC INSULATION TO ALL 172SLABS OR THINNER, AS REQUIRED TO BCA REQUIREMENTS.
14.
-86
15.CONTRACTOR TO CO-ORDINATE CAST IN SERVICES PIPESAND DISPLACE REINFORCEMENT AS REQUIRED TO SUIT.
DENOTES FREEZER/COOLROOM SETDOWN10.
DENOTES 65mm KITCHEN SETDOWN9.
NDRAWING No.
PHA No.
DESIGNED
REDUCTION
DATESCALE @ B1
APPROVED
DRAWN
CHECKED0 25
REV.
THIS IS A CAD DRAWING - DO NOT AMEND MANUALLY
NO DATE AMENDMENT CHECKED
8 COLIN GROVE WEST PERTH WA 6005t: (08) 9322 6033 f: (08) 9324 1691e: [email protected]
Mechanical Consultant
Quantity Surveyor
Electrical Consultant
Hydraulic Consultant
Structural and Civil
Environmental Consultant
BCA Compliance
Mechanical Consultant
Hydraulic Consultant
Landscape Architect
Fire Consultant
BPA EngineeringGround Floor, 460 Roberts Road, Subiaco WA 6000Tel: (08) 93828008 Fax: (08) 93898374 [email protected]
Geoff Hesford EngineeringLevel 1/45 Market Street, Fremantle, WA 6160Mob. 0419 911 166/ 0410 976 571 [email protected]
ETC61 Loftus Street, Leederville WA 6006Tel: (08) 9328 5500 Fax: (08) 9328 5522 [email protected]
SEDGMAN CONSULTINGLevel 1, 202 Pier Street, Perth, WA 6000Tel: (08) 6255 0000 [email protected]
Gabriels Environmental DesignUNIT 3 2 Hardy Street, South Perth WA 6151Tel: (08) 9474 5966 Fax: (08) 9474 5977 [email protected]
ARUPLevel 7, Wellington Central, 836 Wellington Street, West Perth, WA 6005Tel: (08) 9328 5500 Fax: (08) 9328 5522 [email protected]
Ian Lush & AssociatesLevel 2, 2 GEORGE WIENCKE DRIVE, PERTH AIRPORT WA 6105Tel: (08) 9479 5170 Fax: (08) 94772259 [email protected]
Pullyblank Pty Ltd42 Solomon Stret, Fremantle, WA 6160Mob: 0413 056 836 [email protected]
COST PLANNING INTELLIGENCE8 Colin Grove, West Perth, WA 6005Mob: 0419 915 337 [email protected]
HeritageHOCKING HERITAGE STUDIO156 Onslow Road, Shenton Park WA 6008Tel: (08) 938 82810 [email protected]
ACEA
Civil And Structural Consultants
BPA Engineering
E-mail: [email protected]
460 Roberts Road Subiaco, Western Australia 6008
P.O. Box 1308 Subiaco,Facsimile: 61 8 9382 8006Telephone 61 8 9382 8008Western Australia 6008
BPA No. S01217 2As indicated
S30
JAV
FIRST FLOOR PLAN SHEET 1
LT
LT
1557
FEB 2017
CONSTRUCTION
1 : 100
FIRST FLOOR PLAN SHEET 1
WALL SCHEDULE
TYPE DESCRIPTION
RW1 250 THICK CONCRETE RETAINING WALL
RW2 200 THICK CONCRETE RETAINING WALL
RW3 320 THICK DOUBLE BRICK CONCRETE CAVITY RETAININGWALL
RW4 320 THICK DOUBLE BRICK CONCRETE CAVITY RETAININGWALL
SW1 200mm THICK PRECAST CONCRETE PANEL WITHARTWORK TO ARCH. REQUIREMENTS. MINIMUM PANELTHICKNESS 190mm.
SW2 200mm THICK PRECAST CONCRETE PANEL WITHARTWORK TO ARCH. REQUIREMENTS. MINIMUM PANELTHICKNESS 190mm.
W1 250 THICK CONCRETE WALL
W1A 250 THICK CONCRETE WALL + 110 THICK BRICK OUTERSKIN
W2 200 THICK CONCRETE WALL
W3 300 THICK CONCRETE WALL
W5 450 THICK CONCRETE WALL
W6A 100 HIGH x 92 WIDE CONCRETE BUND
W6B 200 HIGH x 200 WIDE CONCRETE BUND
W6C 150 HIGH x 150 WIDE CONCRETE BUND
W8 DOUBLE BRICK 320 CONC CAVITY
W9 190 THICK CORE FILLED BLOCK WALL
W10 90mm BLOCK WALL
W10A 190 THICK CORE FILLED BLOCK WALL + 110 BRICK
W11A 230 DOUBLE BRICK
W11C 285 THICK DOUBLE BRICK WALL
W11E 285 BRICK VENEER
W11F 270 DOUBLE BRICK
W11G BRICK VENEER
W12A 110 THICK SINGLE LEAF BRICK
W12B 110 BRICK FIRE WALL
W12C 110 BRICK FIRE WALL
W13 140 THICK CORE FILLED BLOCK WALL
STRUCTURAL COLUMN SCHEDULE
TYPE DESCRIPTION
CC1 700x350 CONCRETE COLUMN
CC2 Ø500 CONCRETE COLUMN
CC3 500x550 CONCRETE COLUMN
CC4 350 x 600 CONCRETE COLUMN
CC5 400 x 600 CONCRETE COLUMN
CC7 600 x 300 CONCRETE COLUMN
CC8 300 x 300 CONCRETE COLUMN
CC9 300 x 900 CONCRETE COLUMN
SC1* 219.1x8.2 CHS (2HR FIRE RATED)
SC2 100x100x6 SHS
SC2* 100x100x6 SHS (2HR FIRE RATED)
SC3 89x89x6 SHS
SC4 150x150x5.0 SHS
SC5 150x100x4.0 RHS
SC6* 150x150x6.0 SHS (2HR FIRE RATED)
SC7 100x50x4.0 RHS
SC8 100x100x4.0 SHS TRUSS CONNECTOR
SC9 219.1 x 6.3 CHS
SC10 125x125x5.0 SHS
SC11 100x100x6.0 SHS
SC12 125x75x6.0 RHS
SC13 100x100x5.0 SHS
SC14 89x89x5.0 SHS
UA1 100x75x8 UA RWP BLOCKOUT ANGLE FIXED WITH M12ANCHORS AT 300 C/C
STEEL BEAM SCHEDULE
TYPE DESCRIPTION
B1 150x100x4.0 RHS
B2 125 x 75 x 6 RHS
B3 125 x 125 x 5 SHS
B4 150 x 216 D WELDED T-BEAM
B5 125x75x4.0 RHS HEAD MEMBER
B6 100x100x5.0 SHS
B7 150 x 102 D WELDED T-BEAM
B8 150x50x3.0 RHS
B9 200x100x6.0 RHS
B10 89x89x5.0 SHS
BR1 75x 75x6 EA
CH1 139.7x5.4CHS
CJ1 C10019
G1 C15019 GIRTS AT 900 CTRS. MID SPAN BRIDGING.
G2 C10019
P1 Z15019 LAPPED PURLINS AT 1200mm INTERNAL SPAN CRS.900mm END SPAN CRS. 2 ROWS BRIDGING.
RA 100x100x6 EA
SA 100x100x10 EA
SA2 75x 75x6 EA
SB1 200PFC
SB2 250PFC
SB3 200 UB 22
SB4 250 UB 37
SB5 180 UB 18
SB6 250 UB 37
SB7 410 UB 54
SB9 180PFC
WH1 150PFC WINDOW BEAM
WH2 250PFC
FIRST FLOOR CONCRETE BEAM SCHEDULE
TYPE DESCRIPTION
2-B1 250 WIDE x 600 DEEP CONCRETE BEAM
2-B2 250 WIDE x 600 DEEP CONCRETE BEAM
2-B3 250 WIDE x 600 DEEP CONCRETE BEAM
2-B4 250 WIDE x 600 DEEP CONCRETE BEAM
2-B5 250 WIDE x 600 DEEP CONCRETE BEAM
2-B6 450 x 450 DEEP CONCRETE BEAM
2-B7 450 x 450 DEEP CONCRETE BEAM
2-B8 450 x 450 DEEP CONCRETE BEAM
2-B9 450 x 450 DEEP CONCRETE BEAM
2-B10 450 x 450 DEEP CONCRETE BEAM
2-B11 450 x 450 DEEP CONCRETE BEAM
2-B12 250 WIDE x 730 DEEP CONCRETE BEAM
2-B13 250 WIDE x 730 DEEP CONCRETE BEAM
2-DP1 1000 x 1000 x 400 DEEP CONCRETE COLUMN CAPITOL
0 27.10.17 ISSUED FOR TENDER CJ
1 08.01.18 ISSUED FOR CONSTRUCTION CJ
2 23.08.18 ISSUED FOR CONSTRUCTION CJ
2
2
1 2
3
4
5 6
7
8
9
The blue lines show the block walls requested to be scanned to confirm that all cores had been filled.Where a wall is shown with an “ ”, this shows where the wall had not yet been built or had not yet been filled.The numbers correspond with photos for each wall scanned, showing where voids were detected or not detected.
UPUPUP
UPUPUPUP
17
15
13
14
16
11
12
GF H I LKJE
9A B10 C D8
237
237
257
237
257
CC
5
237
257
257
237
CC3
W9
W9
W9
W9
W2
W2W2
W2
W2
W2
W2
W2
W2
SC6*
SC6*
SC6*
SC6*
SC6*
SC6*
SC6*
SC6*
SC6*
CC4
SC2*
SC2*
SC2*
SC2*
SC2*
SC2*
SC2*
SC2*
SC2
SC2*
SC2
SC2*
SC2*
SC2*
SC2*
SC2*SC
2
SC2
SC2
SC2*
SC2
SC2
SC2*
SC3
SC3
SC2*
SC2*
SC2
SC2*
SC2*
SC2
SC2*
SC2
SC2*
SC6*
SC2*
SC3
SC3
SC2*
SC2*
SC2*
SC2*SC
2*
SC2*
SC2*
SC2
SC2
SC2
SC2*
SC2*
SC2*
SC2
SC2
SC3
SC2*
SC2*
SC2*
SC2*
SC2*
SC2
SC2
SC2*
SC2
SC2*
SC3
SC3
SC3
SC2*
SC3
SC2
SC2*SC
2*
SC3
SC3
SC3
SC2*
SC2
SC3
SC3
SC2*
SC6*
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC3
SC2*
SC3
SC2
SC3
SC6*
SC6*
SC2
STAIR 5 STAIR 6
STAIR
2
VOID
CC7
CC7
2-B6
2-B9
2-B8
2-B
7
2-B10
257
257
257
2-B11
W9
W9
W2
CC9
CC9
W11C W11C
W11E
W2
W2
W2
W2
SC3
SC6* SC
6*
SC3
SC3
SC2*
SC3
SC3
SC3
SC3
SC3
SC2*
SC3
W9
SC3
SC3
SC3
SC3
SC3
SC2*
SC6*
SC6*
SC6*
SC6*
SC3
SC3
SC3
SC3
SC3
SC6*
SC2*
SC3
SC6*
SC3
SC3
SC3
SC3
W11E
3-E
S59
3-D
S59
TR2
2-DP1
2-DP1
SC3 SC
3
SC3
SC2*
SC2*
6
S56
150 x 6 SHSFRAME
SC9
SC9
3-F
S59
23
S37
19
S37
20
S37
21
S37
22
S37
24
S37
SC2
SC2
SC2
SC2
SC2
SC2
SC2
UNDERSC
1*
UNDER
SC1*
UNDER
SC1*
UNDERSC
1*
SC2*
SC2*
SW1
SW1
SC3
SC2*
SC2*
SC2*
W12B
B4 UNDER
B7B7
B7
B7
B7
B8
B8
B8
B8
B8
B8
B9
B1 UNDER
PT1
PT1
PT1
PT2
PT1
PT1
PT1
PT1
PT1
PT1
PT2
B7
B7
B7
10
S56
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
14
S56
SS
U1
SS
U2
SS
U1
SS
U1
SS
U2
SS
U1
SS
U2
SS
U1
SS
U1
SS
U1
SS
U2
SS
U1
SS
U1.2
SS
U2
SS
U1
SS
U1
SS
U2
SS
U1
VO
ID VO
ID
VO
ID
SS
U1.2
SS
U1.2
VO
ID
VOID
VOID
VOID
VOID
VOID
VO
ID
W11G
W11GW11G
W11G
SUSPENDED SLAB GENERAL NOTES
DENOTES COLUMN AND LOAD BEARING WALLSUNDER, REFER DRAWINGS S800-S801 FORDETAILS
DENOTES COLUMN ABOVE, REFER DETAIL DRAWINGSFOR DETAILS OF COLUMNS AND WALLS ABOVE
CC?
DENOTES CONSTRUCTION JOINT. 10DAY DELAY BETWEEN ADJACENT POURS
C.J.
200
MJ
B.C.J.
1. FOR GENERAL NOTES REFER TO DRAWING S001- S002
2. ADOPT TYPICAL DETAILS UNLESS NOTED OTHERWISE
3. REFER TO ARCHITECTURAL DETAILS FOR FALLS & LEVELS
4. SLAB THICKNESS NOTATION
DENOTES MINIMUM STRUCTURAL THICKNESS,
NOT INCLUDING FALLS.
5. PROVIDE BOND BREAKER TO ALL LOAD BEARING
SURFACES. PROVIDE COMPRESSIBLE JOINT TO NON LOAD
BEARING SURFACES. REFER TO GENERAL NOTES DRAWING
S001-S002. INSTALL BOND BREAKER IN ACCORDANCE WITH
SUPPLIERS SPECIFICATIONS.
6. REFER TO GENERAL NOTES S001-S002 FOR MASONRY
DETAILS AND REQUIREMENTS. PROVIDE ACOUSTIC WALL
TIES TO PARTITION CAVITY WALLS AS PER
ARCHITECTURAL AND B.C.A REQUIREMENTS.
7.
8.
DENOTES 40mm WET AREA SETDOWN9.
DENOTES SLAB STEP10.
11.
12.
DENOTES MOVEMENT JOINT -BETWEEN SLAB AND WALLS
DENOTES BRICK CONTROLJOINT - VERTICALLY UP WALL
13.PROVIDE ACOUSTIC INSULATION TO ALL 172SLABS OR THINNER, AS REQUIRED TO BCA REQUIREMENTS.
14.
-86
15.CONTRACTOR TO CO-ORDINATE CAST IN SERVICES PIPES ANDDISPLACE REINFORCEMENT AS REQUIRED TO SUIT.
NDRAWING No.
PHA No.
DESIGNED
REDUCTION
DATESCALE @ B1
APPROVED
DRAWN
CHECKED0 25
REV.
THIS IS A CAD DRAWING - DO NOT AMEND MANUALLY
NO DATE AMENDMENT CHECKED
8 COLIN GROVE WEST PERTH WA 6005t: (08) 9322 6033 f: (08) 9324 1691e: [email protected]
Mechanical Consultant
Quantity Surveyor
Electrical Consultant
Hydraulic Consultant
Structural and Civil
Environmental Consultant
BCA Compliance
Mechanical Consultant
Hydraulic Consultant
Landscape Architect
Fire Consultant
BPA EngineeringGround Floor, 460 Roberts Road, Subiaco WA 6000Tel: (08) 93828008 Fax: (08) 93898374 [email protected]
Geoff Hesford EngineeringLevel 1/45 Market Street, Fremantle, WA 6160Mob. 0419 911 166/ 0410 976 571 [email protected]
ETC61 Loftus Street, Leederville WA 6006Tel: (08) 9328 5500 Fax: (08) 9328 5522 [email protected]
SEDGMAN CONSULTINGLevel 1, 202 Pier Street, Perth, WA 6000Tel: (08) 6255 0000 [email protected]
Gabriels Environmental DesignUNIT 3 2 Hardy Street, South Perth WA 6151Tel: (08) 9474 5966 Fax: (08) 9474 5977 [email protected]
ARUPLevel 7, Wellington Central, 836 Wellington Street, West Perth, WA 6005Tel: (08) 9328 5500 Fax: (08) 9328 5522 [email protected]
Ian Lush & AssociatesLevel 2, 2 GEORGE WIENCKE DRIVE, PERTH AIRPORT WA 6105Tel: (08) 9479 5170 Fax: (08) 94772259 [email protected]
Pullyblank Pty Ltd42 Solomon Stret, Fremantle, WA 6160Mob: 0413 056 836 [email protected]
COST PLANNING INTELLIGENCE8 Colin Grove, West Perth, WA 6005Mob: 0419 915 337 [email protected]
HeritageHOCKING HERITAGE STUDIO156 Onslow Road, Shenton Park WA 6008Tel: (08) 938 82810 [email protected]
ACEA
Civil And Structural Consultants
BPA Engineering
E-mail: [email protected]
460 Roberts Road Subiaco, Western Australia 6008
P.O. Box 1308 Subiaco,Facsimile: 61 8 9382 8006Telephone 61 8 9382 8008Western Australia 6008
BPA No. S01217 1As indicated
S31
JAV
FIRST FLOOR PLAN SHEET 2
LT
LT
S01217
FEB 2017
CONSTRUCTION
1 : 100
FIRST FLOOR PLAN SHEET 2
WALL SCHEDULE
TYPE DESCRIPTION
RW1 250 THICK CONCRETE RETAINING WALL
RW2 200 THICK CONCRETE RETAINING WALL
RW3 320 THICK DOUBLE BRICK CONCRETECAVITY RETAINING WALL
RW4 320 THICK DOUBLE BRICK CONCRETECAVITY RETAINING WALL
SW1 350 THICK BRICK SCREEN WALL
W1 250 THICK CONCRETE WALL
W1A 250 THICK CONCRETE WALL + 110THICK BRICK OUTER SKIN
W2 200 THICK CONCRETE WALL
W3 300 THICK CONCRETE WALL
W5 450 THICK CONCRETE WALL
W6A 100 HIGH x 92 WIDE CONCRETE BUND
W6B 200 HIGH x 200 WIDE CONCRETE BUND
W6C 150 HIGH x 150 WIDE CONCRETE BUND
W8 DOUBLE BRICK 320 CONC CAVITY
W9 190 THICK CORE FILLED BLOCK WALL
W10 90mm BLOCK WALL
W10A 190 THICK CORE FILLED BLOCK WALL +110 BRICK
W11A 230 DOUBLE BRICK
W11C 285 THICK DOUBLE BRICK WALL
W11E 285 BRICK VENEER
W11F 270 DOUBLE BRICK
W11G BRICK VENEER
W12A 110 THICK SINGLE LEAF BRICK
W12B 110 BRICK FIRE WALL
W12C 110 BRICK FIRE WALL
W13 140 THICK CORE FILLED BLOCK WALL
FIRST FLOOR CONCRETE BEAM...
TYPE DESCRIPTION
2-B1 250 WIDE x 600 DEEP CONCRETE BEAM
2-B2 250 WIDE x 600 DEEP CONCRETE BEAM
2-B3 250 WIDE x 600 DEEP CONCRETE BEAM
2-B4 250 WIDE x 600 DEEP CONCRETE BEAM
2-B5 250 WIDE x 600 DEEP CONCRETE BEAM
2-B6 450 x 450 DEEP CONCRETE BEAM
2-B7 450 x 450 DEEP CONCRETE BEAM
2-B8 450 x 450 DEEP CONCRETE BEAM
2-B9 450 x 450 DEEP CONCRETE BEAM
2-B10 450 x 450 DEEP CONCRETE BEAM
2-B11 450 x 450 DEEP CONCRETE BEAM
2-B12 250 WIDE x 730 DEEP CONCRETE BEAM
2-B13 250 WIDE x 730 DEEP CONCRETE BEAM
2-DP1 1000 x 1000 x 400 DEEP CONCRETECOLUMN CAPITOL
STEEL BEAM SCHEDULE
TYPE DESCRIPTION
B1 150x100x4.0 RHS
B2 125 x 75 x 6 RHS
B3 125 x 125 x 5 SHS
B4 150 x 216 D WELDED T-BEAM
B5 125x75x4.0 RHS HEAD MEMBER
B6 100x100x5.0 SHS
B7 150 x 102 D WELDED T-BEAM
B8 150x50x3.0 RHS
B9 200x100x6.0 RHS
B10 89x89x5.0 SHS
BR1 75x 75x6 EA
CH1 139.7x5.4CHS
CJ1 C10019
G1 C15019 GIRTS AT 900 CTRS. MIDSPAN BRIDGING.
G2 C10019
P1 Z15019 LAPPED PURLINS AT 1200mmINTERNAL SPAN CRS. 900mm ENDSPAN CRS. 2 ROWS BRIDGING.
RA 100x100x6 EA
SA 100x100x10 EA
SA2 75x 75x6 EA
SB1 200PFC
SB2 250PFC
SB3 200 UB 22
SB4 250 UB 37
SB5 180 UB 18
SB6 250 UB 37
SB7 410 UB 54
SB9 180PFC
WH1 150PFC WINDOW BEAM
WH2 250PFC
STRUCTURAL COLUMN SCHEDULE
TYPE DESCRIPTION
CC1 700x350 CONCRETE COLUMN
CC2 Ø500 CONCRETE COLUMN
CC3 500x550 CONCRETE COLUMN
CC4 350 x 600 CONCRETE COLUMN
CC5 400 x 600 CONCRETE COLUMN
CC7 600 x 300 CONCRETE COLUMN
CC8 300 x 300 CONCRETE COLUMN
CC9 300 x 900 CONCRETE COLUMN
SC1* 219.1x8.2 CHS (2HR FIRE RATED)
SC2 100x100x6 SHS
SC2* 100x100x6 SHS (2HR FIRE RATED)
SC3 89x89x6 SHS
SC4 150x150x5.0 SHS
SC5 150x100x4.0 RHS
SC6* 150x150x6.0 SHS (2HR FIRE RATED)
SC7 100x50x4.0 RHS
SC8 100x100x4.0 SHS TRUSS CONNECTOR
SC9 219.1 x 6.3 CHS
SC10 125x125x5.0 SHS
SC11 100x100x6.0 SHS
SC12 125x75x6.0 RHS
SC13 100x100x5.0 SHS
SC14 89x89x5.0 SHS
UA1 100x75x8 UA RWP BLOCKOUT ANGLEFIXED WITH M12 ANCHORS AT 300 C/C
1
1
1
1
1 08.01.17 ISSUED FOR CONSTRUCTION CJ
1
The following 5 pages show photos of the walls scanned on the first floor.
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 1
Wall 2
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 3
Wall 4No Voids Detected
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 5
Wall 6No Voids Detected
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 7
Wall 8
No Voids Detected
No Voids Detected
2.
P: 08 9294 1832
W: unitedscanning.com.au
P: PO Box 3029, Midland WA 6056
A: Level 8, 251 Adelaide Tce, Perth 6000
ABN: 89 262 952 771
Site Address
Client
Date:
Drawn By:
This is an indication of utilities clearance area or utilities located only, and is to be read in conjunction with the service statement and location terms and conditions of service. The 'As Located' Reference Plan is not to scale and cannot be used as a survey document. Please contact our company for further information if any part of your site clearance is unclear prior to excavation. Be aware of your utility damage potential at conclusion of location service and the associated client duty of care requirements. Review Utility Risk level and Utility Duty of Care Requirements including the WA Utility Code of Practice.
Whilst every effort is taken to accurately record and interpret the images located by the Ground Penetrating Radar, United Scanning Services cannot be held responsible for inaccurate or false interpretation of data, images or reports relating
to target service locations. Design and structural interpretations or opinions expressed by the company or its technicians must be verified by a suitably qualified professional engineer.
Photos
Wall 9
United
decisions. construction informed for allows that concrete into insights provide to technicians periencedxe our allows technology (GPR) Radar
Penetrating Ground 3D Our to. able is Perth in else oneno what provide can services Scanning
We provide the following services:
We offer GPR in Scanning Concrete a safe and timely manner with GSSI and Mala equipment. includes:This
NATA testing Lab Accredited planning rehabilitation for condition concrete relative map - assessment
balconies tunnels, towers, walls, monuments, bridges, - sinspection thickness slab concrete
members structural or walls slabs, concrete in conduits plastic or metallic embedded cables, tension post ,reinforcement steel of depth and location the
demolish or cut drill, to areas safe of
Identify fractures) (voids, concrete inside damage or defects Quality
floors and walls in targets non-metallic and metallic of Location voids and cracks honeycombing, tanking, delamination, of areas identifies that inspection
Condition
alStructurDetermine
DetermineLocation
CAPABILITY STATEMENT.
CONCRETE SCANNING
including equipment GPR of bestthe use Scanning United .Scanners CX aMal and StructureScan GSSI
(08) 9294 1832 [email protected] unitedscanning.com.au
Level 8, 251 Adelaide Tce, Perth WA 6000
ONCRETEC SCANNING
3D Technology Imaging
ACCREDITED LOCATORS FORATCO GASWESTERN POWERDIAL BEFORE YOU DIG
AMCOM WATER CORPORATION TELSTRA
! Safe Work Method Statement (SWMS) Company Name: United Scanning Service PTY LTD Project:
Company Address: Level 8, 251 Adelaide Tce Perth WA ABN No. 89 262 952 771
Job / Trade Activity: USE OF GROUND PENETRATING RADAR, to locate services, P.T cables, re bar and condition prior to client works.
SWMS Prepared by: Name: Sign Date:
!1
LEGISLATION
WA Acts and Regulations Building Regulations 1989Dangerous Goods Safety Act 2004Occupational Safety and Health Act 1984
Occupational Safety and Health Regulations 1996Electricity Regulations 1947Electricity (Licensing) Regulations 1991
WA Codes of Practice
(relevant to construction work, tick as applicable to work)
" Concrete and masonry cutting and drilling, 2010
! Excavation, 2005
" First aid, workplace amenities and personal protective clothing, 2002
" Manual handling, 2000
" Managing noise at workplaces, 2002
! Safe design of buildings and structures, 2008
" The Prevention of falls at workplaces, 2004
! Tilt-up and precast concrete construction, 2004
" Violence aggression and bullying at work, 2006
" Working hours, 2006
Australian Standards As quoted in legislation and codes of practice
! Safe Work Method Statement (SWMS) National Standards (relevant to construction, tick as applicable to work)
☑ National Standard for Construction Work[NOHSC:1016(2005)]
☑ Adopted National Exposure StandardsFor Atmospheric Contaminants In TheOccupational Environment [NOHSC:1003(1995)]
☑ National model regulation for the controlof scheduled carcinogenic substances [NOHSC:1011(1995)]
☑ National Standard for Manual Tasks(2007)
☑ National OHS Certification Standard forUsers and Operators of Industrial Equipment- 3rd Edition [NOHSC:1006(2001)]
☑ National Standard for the Storage andHandling of Workplace Dangerous Goods [NOHSC:1015(2001)]
☑ National Model Regulation for theControl of Workplace Hazardous Substances
☑ National Standard for LicensingPersons Performing High Risk Work
☑ National Standard for OccupationalNoise [NOHSC:1007(2000)]
☑ National Standard for Plant [NOHSC:1010(1994)]
◻ National Standard for SyntheticMineral
National Codes of Practice (relevant to construction work, tick as applicable to work)
◻ Safe Removal of Asbestos 2nd Edition [NOHSC:2002(2005)]
◻ Code of Practice for the Management and Control of Asbestos in the Workplace [NOHSC:2018(2005)]
☑ Code of Practice for the Control of Scheduled Carcinogenic Substances [NOHSC:2014(1995)]
☑ National Code of Practice for Induction for Construction Work (May 2007)
◻ National Code of Practice for Precast, Tilt-up and Concrete Elements in Building Construction (2008)
☑ National Code of Practice for the Prevention of Falls in General Construction (2008)
☑ National Code of Practice for the Storage and Handing of Dangerous Goods [NOHSC:2017(2001)]
☑ National Code of Practice for the Control of Workplace Hazardous Substances [NOHSC:2007(1994)]
☑ National Code of Practice for the Control of Work Related Exposure to Hepatitis and HIV (blood-borne) Viruses[NOHSC:2010(2003)]
◻ National Code of Practice for the Control and Safe Use of Inorganic Lead at Work [NOHSC:2015(1994)]
☑ National Code of Practice for the Labelling of Workplace Substances [NOHSC:2012(1994)]
☑ National Code of Practice for the Prevention of Muskuloskeletal Disorders Caused From Performing Manual Tasks
☑ National Code of Practice for Noise Management and Protection of Hearing at Work - 3rd Edition [NOHSC:2009(2004)]
◻ National Code of Practice for the Safe Use of Synthetic Mineral Fibres [NOHSC:2006(1990)]
National Guidance Notes
◻ Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres 2nd Edition [NOHSC:3003(2005)]
☑ Guidance Note on the Interpretation of Exposure Standards for Atmospheric Contaminants in the OccupationalEnvironment 3rd Edition [NOHSC:3008(1995)] (HTML)
☑ Guidelines for Integrating OHS into National Industry Training Packages
◻ Guidance Note for Placarding Stores for Dangerous Goods and Specified Hazardous Substances [NOHSC:3009 !2
! Safe Work Method Statement (SWMS)
PERMITS TO WORK (✓) ◻ Work at Height (unprotected over 2m) ◻ Confined Space ◻ Hot Work
◻ Excavation ☑ Concrete Cutting/Drilling ◻ Other (specify)
MINIMUM PPE (✓) ☑ Safety Glasses (medium impact) ☑ Hi-Visibility vest or shirt ☑ Hard Hat
☑ Safety Footwear ☑ Hearing Protection (<85dB) ◻ Other (specify)
!3
EQUIPMENT / TOOLS (✓) ☑ Hazard WarningSigns
☑ Barricade orGuarding
◻ EWP (Scissor Lift / Boom Lift) ☑ Power Tools
◻ Scaffolds ◻ Portable Ladder(s) ◻ Safety Harness ◻ Other (specify)
!
Safe Work Method Statement (SWMS)
Level Description of Consequence or Impact ConsequenceLikelihood / Probability
LLikely
MModerate
UUnlikely
H (1)
(High level of harm)
Potential death, permanent disability or major structural failure/damage. Off-site environmental discharge/release not contained and significant long-term environmental harm.
H (1)
(High) 1 1 2
M (2)(Medium level of
harm)
Potential temporary disability or minor structural failure/damage.On-site environmental discharge/release contained, minor remediation required, short-term environmental harm.
M (2)(Medium) 1 2 3
L (3)(Low level of
harm)
Incident that has the potential to cause persons to require first aid.On-site environmental discharge/release immediately contained minor level clean up with no short-term environmental harm.
L (3)(Low) 2 3 3
Level Likelihood / Probability
Likely Could happen frequently
Moderate Could happen occasionally
Unlikely May occur only in exceptional circumstances
Health and Safety Environment
Catastrophic Fatality or permanent disability (Class 1 incident) High severity which has or may have permanent and/or irreversible effects (Level 1)
Major Life threatening incident, Lost Time Injury or ongoing illness/health effects (Class 2 incident)
Medium severity which has or may have persistent but reversible effects (Level 2)
Moderate Incident that requires medical treatment by a qualified medical practitioner (Class 3 incident)
Low severity which has short term and reversible effects (Level 3 incident)
Minor Incident that may require first aid treatment only Impact confined to area impacted by work operations
Insignificant No injuries Very low environmental impact, not noticeable
!
Most Effective
Least Effective
Elimination Eg Eliminate the need for a fall risk area by careful design
Substitution Eg Barricading or enclosing the fall risk area with edge protection
Isolation Eg Isolating the hazard or practice from people involved in the work
Engineering Eg Using a fall injury prevention system
Administrative Eg Procedures, training, warning signs, limiting exposure time
PPE Eg Use of Personal Protective Equipment
Risk Hierarchy of Control - Preferred Order of Control Measures to Eliminate or reduce risks of injury or illness.To calculate Inherent and Residual risk, refer to ‘Qualitative Risk Analysis Matrix: Level of Risk’ on Page 2
4
! Safe Work Method Statement (SWMS)
1 General planning Scanning, Drilling / Coring
Inadequate training / instruction / supervision.
M (2)(Medium)
Matthew Hill to ensure all employees:• Attend a construction industry “Safety
Awareness Course Blue Card.
• Attend a site-specific induction.
• Attend a Daily Prestart
Provide supervision on the site.Make sure the employees are instructed in the correct use of:
• Personal Protective Equipment (PPE).• Tools, equipment and plant• Hazardous substances and chemicals (Provide
Material Safety Data Sheets - MSDS).• Clean work areas regularly.
Ensure that Personnel contact Site Manager for the following;
• Access to Site Inductions• Ensure sign in complete• Plant equipment onsite
• Hazardous substances• Permit to Work to be opened prior to work
commencing
Deliver materials to a safe lay down area as close as possible to the work. Undertake Take 5 prior to commencing task.
Note: If you identify additional risks and their control measures are not listed on this SWMS, set them out on an additional SWMS Worksheet and attach to the end of this SWMS
Matthew Hill
L (3)(Low)
!
No
Job Step(break the job down into steps)
Potential Hazards(what can harm you or
others?)
Inherent Risk*(Likelihood x Consequence
)
Controls & Checks Required(What are you going to do to carry out the work
safely – apply risk hierarchy of control)
Who is Responsible?(Position Title)
Residual Risk*
(Likelihood x
Consequence)
5
! Safe Work Method Statement (SWMS)
2 Inspect the work area before work begins for the day.
Hazards caused through work activity:
• Obstructed access.• Poor housekeeping
causing manual handlinginjuries/slips trips andfalls.
• Other personnel injuredfrom other work activities.
M (2) (Medium)
• Complete Take 5• Inspect the work area for hazards before work• Provide safe access to all work areas.• Clean up work areas on a regular basis.• Make sure signs and barriers are erected in
areas where required.
Operator
L (3) (Low)
3 General planning Areas been scanned for Client works
• Electrical services H (1) (High)
Prior to scanning ensure all exposed electrical cables that are in the area to be scanned are made safe or switched off
( This does not include cables in conduits that are in the slab to be scanned.)
Operator
L (3) (Low)
4 Scan Area where worksrequired.
Manual Handling
Slips and Trips M (2) (Medium)
• Equipment is brought to site via a trolley asrequired
• Ensure work area is clear and free of obstacles
Operator
L (3) (Low)
5 Planning For scanning - Arrive on site
- Site traffic and personalinterference
M (2) (Medium)
United Scanning employee/s - consult with site Superviser- Ensure Necessary Permits are obtained- Wear correct PPE before entering site- Take care during site movement- Sign In prior to undertaking work.
Operator
L (3) (Low)
!6
Date services•
! Safe Work Method Statement (SWMS) 6 - Meet with client, discuss job
- Site Induction- Activity of other workers- General site environment eg.objects or liquids on the ground.- Inadequate training andsupervision of employees M (2)
(Medium)
United Scanning employee/s Client - Wear correct PPE- Take care during site movement- Have a blue/white card- Attend site specific induction Shell / Swan- Attend Prestart and Tool box meetings- Ensure Relevant Permits Obtained- Check notice board- Ensure appropriate training and tickets have beenacquired
Operator
L (3) (Low)
7 - Check work area - Unsafe work environments, egexcavations, confined spaces,chemical presence etc- Inadequate airflow- Inadequate lighting- Obstructed or insufficient accessand/or egress- Poor housekeeping- Uncomfortable or cramped workconditions- Unstable footing- Work activity of others- Weather conditions
M (2) (Medium)
United Scanning employee/s Client
• Inspect the work area for hazards• Eliminate hazards where possible.• Ensure appropriate measures are taken should
hazards exist.• Raise any safety concerns with supervisor and
do not conduct work activity until all safetyconcerns are adequately dealt with
• Ensure safe access and egress is in place• Cleanup work area• Ensure there is adequate airflow• Ensure there is adequate lighting• Erect signs and barricading around area• Ensure firm footing• Ensure the weather conditions are conducive to
safe work activity, i.e. comfortable workingtemperature and dry. Use sunscreen and weartrousers and long sleeve shirts when exposed todirect sunlight
• Have First Aid Kit in close proximity and befamiliar with first aid personal
Operator
L (3) (Low)
!7
8 General Planning and considerations
- Presence of other trades- Presence of general public
M (2)(Medium)
United Scanning employee/sClien- Obtain permits as applicable- Complete (United Scanning) general proceduresstart checks
Operator L (3)(Low)
9 Set up;-Carry tools and equipment to worksite-Set up tools and equipmentand barricades
- Heavy equipment- Creation of obstacles- Faulty equipment M (2)
(Medium)
United Scanning employee/s- Limit load size- Use correct/alternative manual handling techniques- Keep work area neat and clean- Clear area of slip and trip hazards- Be aware of surroundings-Wear correct PPE- Ensure regular workshop servicing and completemachinery pre start check lists
Operator L (3)(Low)
! Safe Work Method Statement (SWMS)
10 Housekeeping Trips and slips.
M (2)(Medium)
Housekeeping standards are adequate to prevent other trades, personnel or members of the public from slipping or tripping on materials or associated discarded rubbish.
• Work areas are left clean and safe at the end ofeach working day.
• To prevent injury from poor housekeeping makesure:
• Workers are trained in good housekeepingpractices.
• Regular clean-ups occur throughout the workingday and at the conclusion
• Permit to be closed on completion, ofwork.
Discarded materials and rubbish is placed in designated areas or bins/skips.
Access ways are not obstructed by rubbish from work activity.
Operator
L (3)(Low)
11Working near the public injury to public:
• Trips / slips / falls• Struck by plant M (2)
(Medium)
When working near the public:• Erect rigid barriers and warning. Signs.• Follow site traffic management plan• Remove or make safe material stacks.• Make excavations safe or use a 1.8 metre
security fence for open excavations.
Operator
L (3)(Low)
!8
! Safe Work Method Statement (SWMS)
Employees involved in consultation, development and acceptance of this Safe Work Method Statement
Revisions 1 2 3 4 5
Initial / Date Jan 2018
Print Name: Signature Date signed Print Name: Signature Date signed
Personnel qualifications and experience required to complete the task (eg work at heights training)
Specific training required to complete this task: Engineering Details/Certificate/Regulatory Approvals
Site Induction
Construction Industry Safety Awareness Training
!9
Allistair Higgs 08-02-2019
!
Job Safety Analysis Checklist
Safety Hazards
❒ Fall to below
❒ Contact with Chemicals ❒ Fall to same level
❒ Contact with Pressure ❒ Dropped objects
❒ Overstress, strain, sprain ❒ Struck against
❒ Fire ❒ Struck by
❒ Explosion ❒ Caught between
❒ Engulfment
❒ Cuts / Abrasion
❒ Oxygen deficiency / excess
❒ Flying particles
❒ Atmospheric contaminants
❒ Burns - Hot, Cold, Acid
❒ Electrical contact
Health Hazards
❒Heat Stress
❒ Dust ❒Noise
❒ Biological Hazards ❒Radiation
❒ Synthetic Mineral Fibres ❒Vibration
❒ Asbestos ❒Contact with Chemicals
❒ Atmospheric Contaminants
Environmental Hazards
❒Chemicals
❒ Chemical Spills
! 10
Emergency Company Contact Information
Contact: Matthew Hill Position: Director Phone: 0433 724 921 Email: [email protected]
❒General Rubbish ❒ Hazardous Waste