computed radiography digital radiography leeann pack dvm diplomate acvr

23
Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

Upload: alejandro-holdway

Post on 31-Mar-2015

250 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

Computed RadiographyDigital Radiography

LeeAnn Pack DVM

Diplomate ACVR

Page 2: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

Computed Radiography (CR)

• Been around since 1980-81

• Uses same radiographic equipment– No change in X-ray machine

• Uses an imaging plate– Contains a photostimulator phosphor

• Need a cassette reader

• Images can be sent to a PACS

Page 3: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

CT System

Page 4: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

CR cons

• Still need imaging plates

• Cost of plates is expensive

• Same amount of time to produce the image as with film

• Processing time

• Increased exposure when compared to film and DR

Page 5: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

DR

• Works like a digital camera– Images are seen immediately

• Two options– CCD– Digital flat plate detector

• Can be sent to PACS• Small decrease in tech time/time to

development when compared to CR

Page 6: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

DR• No film costs• No darkroom space• No processor to maintain• No films to search for or file• No expense for film jackets• Increased productivity• Decreased retakes• Decreased exposure (Eklin)

Page 7: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

Digital Flat Plate Detectors

• Expensive ($80,000-120,000)• Can retrofit into existing X-ray machines• Eklin

– Exposure is decreased thus improving radiation safety

• Do not use grid but use image software

• IDEXX• Sound Technologies

Page 8: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

DR Portable System - EKLIN

Page 9: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

DR – Portable with Carrier

Page 10: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

DR Portable System - IDEXX

Page 11: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

CCD

• Is sold with an X-ray machine

• Camera is placed in machine before install – fits underneath the table

• Less expensive than the Flat Plate Detector

• Cause increase in exposure by 2 times– Double the mAs

Page 12: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

Potential Cost Savings• Film• Space

– Wont need the darkroom space

• Processor– Maintenance

• Less technician time– Decreased repeats and no developing

• Time lost looking for films

Page 13: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

Images

• Ability to window exposures– Works like CT– Wider latitude for exposures

• Less retakes

– Better soft tissue – Image consistency

Page 14: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

PACS

• Picture – viewing at workstations• Archiving – images short/long term• Communication –local or wide area

networks • System – use with HIS, other equip. ect.• Method that allows storing, retrieving,

distributing throughout your hospital or the internet

Page 15: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

PACS

• Once an image is made – it is sent to the local PACS – a copy is also sent somewhere else (in house server, off site server)

• Then the image can be pulled up and viewed– Multiple sites throughout the hospital

Page 16: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

EKLIN

Page 17: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

DICOM

• Digital Imaging and Communications in Medicine

• Imaging standard that allows multiple pieces of medical equipment to communicate

• Essentially all PACS and almost all equipment speak DICOM now

• DICOM does not effect image quality

Page 18: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

Computer Monitors

• Bigger really is better– Small monitor can not see entire image

• Some choose grey scale monitors– More expensive (3MP)

• Some choose the Dell monitor – Less costly (2MP)

Page 19: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

Dell 2407 HC

Page 20: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

Image Back Up

• Must have a way to back up copies of images in case your computer crashes

• Time to “keep” images varies by province/state

• 3 options– On site server– Off site server– Fingers crossed storage

Page 21: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

Teleradiology

• Can send your images to a radiologist for interpretation– Should be of diagnostic quality

• Buy machine they add in contract with radiologists– Be careful

Page 22: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

Hospital Integration

• Can integrate the images you take into the patients hospital record– If hospital is automated

• Referral veterinarians can view images you have made and also receive reports

Page 23: Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR

• Images used in this presentation from– www.eklin.com– www.idexx.com– www.dell.com