Page 1: Components - Franke

Components

Tower

Water Vacuum Supply Center

Page 2: Components - Franke

Air / Water Flow

Page 3: Components - Franke

Water / Descale Inlet

V1-Water inlet valve • Water inlet to unit V13-Descale • Only used for descale Both protected by

check valves

Page 4: Components - Franke
Page 5: Components - Franke

Water Pump

M1-Water Pump • Set at 90 PSI at the factory. • Adjustments may be

required during calibrations.

Page 6: Components - Franke
Page 7: Components - Franke

Flow Meter

FM-Flow Meter • Measures the volume of water

flowing through the unit

Page 8: Components - Franke
Page 9: Components - Franke

Thermoblock 1

TB1-Thermoblock 1-cold water • Heats the water to 45°C (113°F) • NTC Probe monitors the

temperature • Hi-limit trips at 75°C (167°F)

Page 10: Components - Franke
Page 11: Components - Franke

Thermoblock 2 & 3

TB2-Thermoblock 2 & TB3-Thermoblock 3-hot water • Heat the water to 120°C (248°F) • NTC Probe monitors the

temperature • Hi-limits trip at 150°C (302°F)

Page 12: Components - Franke
Page 13: Components - Franke

Proportional / Mixing Valve

V5-Mixing Valve • Regulates the flow of cold

water

Page 14: Components - Franke
Page 15: Components - Franke

Brewing Valve

V11-Brewing valve • Activates during the brew

cycle

Page 16: Components - Franke
Page 17: Components - Franke

Safety Overpressure Valve

UV1-Safety Valve • Set at 12 bar

Page 18: Components - Franke
Page 19: Components - Franke

Air Sanitizing Valve

V2-Air Sanitizing Valve • “Clean in Place” Cycle • “Descale” Cycle

Page 20: Components - Franke
Page 21: Components - Franke

Overpressure Relief Valve

UV3-Overpressure Relief Valve • Opens at 3 bar • Prevents steam in the lines

Flow Direction

Page 22: Components - Franke
Page 23: Components - Franke

Overpressure Valve

UV2-Overpressure Relief Valve • Opens at 3 bar • Prevents steam in the lines

Flow Direction

Page 24: Components - Franke
Page 25: Components - Franke

Temperature Sensor

T-mix-Temperature Sensor • Measures the temperature of

the combined cold and hot water

Page 26: Components - Franke
Page 27: Components - Franke

Fill Valve

V3-Fill Valve • Energized to fill brew

chamber • Located on the top of the

tower

Page 28: Components - Franke
Page 29: Components - Franke

Rinse Valve

V4-Rinse Valve • Energized to rinse brew

chamber • Located on the top of the

tower

Page 30: Components - Franke
Page 31: Components - Franke

Flow Regulator-Water

FR1-Flow Regulator • Located on the top of the

tower • **Currently not being used**

Page 32: Components - Franke
Page 33: Components - Franke

Brew Chamber

BC-Brew Chamber • Water and ingredients mix • Vacuum and purge occur

Page 34: Components - Franke

Flow Regulator-Vacuum Leak

FR2-Flow Regulator • Regulates the volume of

air entering the unit.

Page 35: Components - Franke

FR2 Flow Regulator

PS Pressure Sensor

V6 Atmosphere Valve

BC Brew chamber

M2 Vacuum Pump

Atmosphere

Page 36: Components - Franke

Pressure Sensor

PS-Pressure Sensor • Measures the air pressure in

the vacuum and purge lines

Page 37: Components - Franke

FR2 Flow Regulator

PS Pressure Sensor

V6 Atmosphere Valve

BC Brew chamber

M2 Vacuum Pump

Atmosphere

Page 38: Components - Franke

Atmosphere Valve

V6-Atmosphere Valve • Allows air to escape brew

chamber • Energized for vacuum and purge • Located on the top of the tower

Page 39: Components - Franke

FR2 Flow Regulator

PS Pressure Sensor

V6 Atmosphere Valve

BC Brew chamber

M2 Vacuum Pump

Atmosphere

Page 40: Components - Franke
Page 41: Components - Franke

Water Separator

WS-Air-Water Separator • Prevents water from

reaching the vacuum pump

Page 42: Components - Franke
Page 43: Components - Franke

Blowout Valve

V8-Blowout Valve • Energized to clear and drain

the Air-water separator

Page 44: Components - Franke
Page 45: Components - Franke

Vacuum Valve

V10-Vacuum valve • Energized to create vacuum

Page 46: Components - Franke
Page 47: Components - Franke

Vacuum Pump

M2-Vacuum Pump • Used for creating a vacuum • Used for purging brew

chamber • Used for flushing WS & V8

Page 48: Components - Franke
Page 49: Components - Franke

Flush Valve

V9-Flush Valve • Energized to flush brew

chamber

Page 50: Components - Franke
Page 51: Components - Franke

Purge Valve

Purge Valve • Located on the brew handle • Opens at 3 PSI

Page 52: Components - Franke
Page 53: Components - Franke