comparison+of+switches

Upload: anitha-anu

Post on 30-Oct-2015

27 views

Category:

Documents


0 download

DESCRIPTION

c

TRANSCRIPT

Sheet1FEATURESC-DOTOCB-283E10BEWSD5ESSAXE-10Version2_2_1_9R252L+Ver 16version 16IN56 (local) / IN73(TAX)Sw TypeTSTTTSTTSSSTTSTTST / TSNo of subs400002,00,000450002,42,760650002,00,000No of trunks1500060000 (2048 PCM)5000 (384 PCM)60000 (2048 PCM)1800060000 (2048 PCM)Traffic in Erlangs8000250004000252002520026000BHCA8 LAKH8 Lakh1.96 Lakh14 Lakh14 LAKH8 LakhMaintanace TypePreventivePreventiveCorrectivePreventivePreventivePreventiveSignallingCAS / CCSCAS / CCSR2MF / CASCAS / CCSCAS / CCSCAS / CCSCDR CompatabilityYesYesNoYesYesNo / YesSTPYesNoYesYesNo / YesCENTREXYesYesNoYesYESYesLATEST S/W FUNCTIONCENTREXCDRPRBT,CDRCENTREX ,PRBTSTP,CDR,PRBTLATEST H/W FUNCTIONSTM-1 TERMINATIONLOCAL,TAXALLLOCALLOCALLOCAL,TAXENVIRONMENT CONDITIONSTemperature24 to 4823+/- 3 C1820 TO25'C5 to 40'cHumidity45+/-15%55%15 to 80%False flooringDEPENDS ON REQNeededDEPENDS ON REQD BOTH POSSIBLENot neededCable connectivityBack endBack endBACK ENDBACK ENDFront end connectivityFront end connectivityRack installation (occupied space)Single row (more)ROW BY ROWBack to back (less)Power consumtion700A (50K MSU)300A ( 10K MSU)Power per line1 to 1.4 WattCHARGINGCONNECTED TONDNENESNBSNBTYPEA,B,NO PARTYA,B NO PARTYA,B,NO PARTYCHARGE METERS4454METER DUMP FILEGTLCCA.SU.CHACMVNFILEDETAIL BILL FILENCBR FileGTDTGTDTIA.ICAMATTFILEH/WSUBS -MSUATU - (BM)CSNLCSEL / URALDLU LOCALLSM (SM)LSS (EMG)SUBS-RSUATU - (RBM)CSNDCSED / URADDLU REMOTERSMRSS (EMG)TRUNKDTUSMTURMLTG -P/LTG-M/N/GDLTU/SMTSSSWITCHTSU(BM), SSU/CMSMXCXSN-BSM(Time),CM(Space)GSSCONTROLAMSMCUGCXCPAMCP / RPO&MIOMSMMOMCOMTCU/AMIOG12 / IOG20 / APG40CLOCKNSCSTSBTCCGNCLK/CMCLMCCS7SUMSMA (PUPE)-CCNCPSU/SMTSS (C7STD)CAS/R2MFDTUSMTETA(LTG)PSU/SMTSS (CSRD)CONFERENCESMA(ICTSH)CCFCOUBESS (CCD)ANNOUNCEMENTSANNCSMM(ICMPN2)BDADAS/OCANEQDSU2-SAS/RAFESS (ASMD)CONNECTIVITY (CTRL PATH)HDLCMIS-1,MAS -4SDC (8 Mbps)DSCH / CLNKBUSCONNECTIVITY (CALL PATH)PCMLR (PCM 2Mbps)LR (2Mbps)PDC (2Mbps/4Mbps))NCTPCM (2Mbps)SUBS. EQUIPMNTRack-msuATU/ BMCSNLCSEL/URALDLU LOCALLSS (EMG)Rack-RsuATU/RBMCSNDCSED/URADDLU REMOTERSS (EMG)MAX SUBS RACK32255256Max-Anlog/ UNIT20245000/CSN1024952/1760/19042048Max-ISDN/rack256 B Chls928/1536Max-Anlog /shelf128256/SHELF512128Max-Bra /shelf12825616 / 32subs card-POTS(Capacity)LCC (8)TABASE(16)XEJ16SLMA(8)/16/32LPZ100B (32)LIB7(4) / LIB8(8) (LI3)subs card-ISDN (Capacity)BRL, PRLTAN3G (8 ) TADP(PRI)SLMD(8)/16LPU112 (12)DLB2 (LIBA)Reversal card (Capacity)CCM (8)TABAF (16)XEJ8SLMACMRL(6)/16/32LPZ100B (32)All line cards16Khz pulse card (Capacity)CCB (7th,8th port)TABAF (16)XEJ8SLMACMRL(6)/16/32LCP100B (24)SEPRM (8)Power sharing in shelfsYesYESYESNOTONE GENERATORTGAETAETATOG-CRGPTSWKRDTMF RECEIVERMFCETAETACRP8DFITSWKRTESTER (CARD/ LINE)TTCTMLABLCMM/FMTUSLIMSLCT / SULTDPCM Interface ( MSU /RSU)ESM/CM, ETS/RBMTTRS /RSUURMDIULDIM/DIUC76JTB / ETBMAX PCM (SHELF /RACK)128/SMT32PCMS/RACK4MBPS/DLURACK2 / 32CONCENTRAION (AVILABLE)4:110:110:11:810:11 : 2CONCENTRAION (GIVEN)4:1, 8:110:11:81 : 8STAND ALONEYesYesLimitedYES (Cluster)YesYES ( Internal)STAND ALONE MeteringCharged ( Updated)Free (Lost)Free (Lost)Free (Lost)Charged ( Updated)Free (Lost)DOUBLE REMOTINGNoYesYesNoNoNoSUBS. CommandsCreationCRE-SUBABOCRABOCRCRSUBSULIIFacility provide / ChangesMOD-SUB-FACABOMOABOMOMODSUBSUSCCSUBS. Facilities DisplayDISPL-SUBABOINABOINDISPSUBSUSCPMeteringDISPL-SUB-MTRABOINABOINDISPMETCHSIPTesting (Card / line)TST-TRMESABABESLTESTDLULC/TESTSUBSLOCI / SLOMIALARMSDISPL-SYS-ALLALAILALAILDISPALARMALLIPNE Formatbmno-rackno-fr.no-slotno-portnoUrno-tmnleqptno-portnoUrno-tmnleqptno-portnoDLU-SHELF-MOD-PORTLI3- xxxxxxSUBS. FacilitiesAbb.dailingNA2/NA4ALL LINES (ABBD-20)All lines ( ADI )Morning AlarmAUTO-ALRMALL LINESAll linesDynamic lockSUB-OG-BARREDSRCALL LINESAll lines ( KWC )Call transferRVTALL LINESAll lines (CFUV )Call waitIAIALL LINESAll lines (CAW )ClipCLIPTY=DTMF, CAT=DIPAALL LINESAll lines (IPT,ANT,APT)ReversalCCB_CRDTTX(Home metering)SLMACMRL/FPE/ITFAll lines (TLI )Hot lineTIMED HTLN/UNTIMED HTLNLAIALL LINESAll lines ( FDC )PREVIOUS YEAR QUESTIONSCC7 implemented inSUMPU/PESSNC/CCNCPSUPCDD / C7STDCDR Stored inIOPSMMIA.ICAMAAMIOG / APGSYNCHRONISATIONNSCSTSCCGCLMIP interface in H/W (EWSD)LTG-HTransmission testingATE-TM/TEM-LEGDSUSubs. Parameter in CommandDISPSUBdirnrSNBBORSHCT FunctionLCC/CCMTABASEXEJ16SLMCPLIB7 / LIB8O&M PeripheralsConsole,OOD,ADP, PrinterOMPC/CV,CONSOLES,PCWAMMITRA225,MDDMOD,OMT,SYP,X.25HDD,MTD,ODD, EXTERNAL ALARMS, TERMINALS,TRUNK EQUIPMNTSMTURMLTGTSSPCM i/f card (No of pcm)1 DTS- 1 PCMICTRQDIU120AETC (1)MAX PCM PER RACK15 E1 / Main rack128/SMT32/RACK96O & MEquipmentIOMSMMMITRA 225AMIOG 12BMAX No OF Terminals8 terminals3226416HDD CAPACITY8GB4GB50/60MB HD2GB2 GBCONTROLCPCPCPNo of processorsDISTRIBUTE PROS2 ( SPU, IPU )SW .EQUIPMENTTIME SwTSU/BMSMXCXSNSMTSM/GSSNo of TIME sw inlets1024 TS2048PCM384PCMS204830K TS16 PCMsSPACE SwSSU/CMCMSPMNo of SPACE sw inlets64 x 6432 TSMBlocking factor

Sheet2

Sheet3