comparison of fixation of the femoral component without cement and fixation with use of a...

13
Comparison of Fixation of the Femoral Component without Cement and Fixation with Use of a Bone- Vacuum Cementing Technique for the Prevention of Fat Embolism During Total Hip Arthroplasty. A Prospective, Randomized Clinical Trial* by ROCCO PAOLO PITTO, MATTHIAS KOESSLER, and JOERN W. KUEHLE J Bone Joint Surg Am Volume 81(6):831-43 June 1, 1999 ©1999 by The Journal of Bone and Joint Surgery, Inc.

Upload: everett-webster

Post on 12-Jan-2016

226 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Comparison of Fixation of the Femoral Component without Cement and Fixation with Use of a Bone-Vacuum Cementing Technique for the Prevention of Fat Embolism

Comparison of Fixation of the Femoral Component without Cement and Fixation with Use of a Bone-Vacuum

Cementing Technique for the Prevention of Fat Embolism During Total Hip Arthroplasty. A Prospective, Randomized

Clinical Trial*

by ROCCO PAOLO PITTO, MATTHIAS KOESSLER, and JOERN W. KUEHLE

J Bone Joint Surg AmVolume 81(6):831-43

June 1, 1999

©1999 by The Journal of Bone and Joint Surgery, Inc.

Page 2: Comparison of Fixation of the Femoral Component without Cement and Fixation with Use of a Bone-Vacuum Cementing Technique for the Prevention of Fat Embolism

Fig. 1 Drawing showing the position of the proximal drainage cannula that is used in the bone-vacuum cementing technique.

ROCCO PAOLO PITTO et al. J Bone Joint Surg Am 1999;81:831-43

©1999 by The Journal of Bone and Joint Surgery, Inc.

Page 3: Comparison of Fixation of the Femoral Component without Cement and Fixation with Use of a Bone-Vacuum Cementing Technique for the Prevention of Fat Embolism

Fig. 2 Drawing showing the positions of the two 4.5-millimeter-diameter cannulae that are used in the bone-vacuum cementing technique.

ROCCO PAOLO PITTO et al. J Bone Joint Surg Am 1999;81:831-43

©1999 by The Journal of Bone and Joint Surgery, Inc.

Page 4: Comparison of Fixation of the Femoral Component without Cement and Fixation with Use of a Bone-Vacuum Cementing Technique for the Prevention of Fat Embolism

Figs. 3-A through 3-D: Transesophageal echocardiograms made during total hip arthroplasty, showing the main echogenic patterns.

ROCCO PAOLO PITTO et al. J Bone Joint Surg Am 1999;81:831-43

©1999 by The Journal of Bone and Joint Surgery, Inc.

Page 5: Comparison of Fixation of the Femoral Component without Cement and Fixation with Use of a Bone-Vacuum Cementing Technique for the Prevention of Fat Embolism

Fig. 3-B Grade 1.

ROCCO PAOLO PITTO et al. J Bone Joint Surg Am 1999;81:831-43

©1999 by The Journal of Bone and Joint Surgery, Inc.

Page 6: Comparison of Fixation of the Femoral Component without Cement and Fixation with Use of a Bone-Vacuum Cementing Technique for the Prevention of Fat Embolism

Fig. 3-C Grade 2.

ROCCO PAOLO PITTO et al. J Bone Joint Surg Am 1999;81:831-43

©1999 by The Journal of Bone and Joint Surgery, Inc.

Page 7: Comparison of Fixation of the Femoral Component without Cement and Fixation with Use of a Bone-Vacuum Cementing Technique for the Prevention of Fat Embolism

Fig. 3-D Grade 3.

ROCCO PAOLO PITTO et al. J Bone Joint Surg Am 1999;81:831-43

©1999 by The Journal of Bone and Joint Surgery, Inc.

Page 8: Comparison of Fixation of the Femoral Component without Cement and Fixation with Use of a Bone-Vacuum Cementing Technique for the Prevention of Fat Embolism

Figs. 4-A and 4-B: Graphs showing the distribution of embolic events observed with transesophageal echocardiography in the three groups of patients.

ROCCO PAOLO PITTO et al. J Bone Joint Surg Am 1999;81:831-43

©1999 by The Journal of Bone and Joint Surgery, Inc.

Page 9: Comparison of Fixation of the Femoral Component without Cement and Fixation with Use of a Bone-Vacuum Cementing Technique for the Prevention of Fat Embolism

Fig. 4-B Distribution of embolic events observed a few seconds after the relocation of the hip joint.

ROCCO PAOLO PITTO et al. J Bone Joint Surg Am 1999;81:831-43

©1999 by The Journal of Bone and Joint Surgery, Inc.

Page 10: Comparison of Fixation of the Femoral Component without Cement and Fixation with Use of a Bone-Vacuum Cementing Technique for the Prevention of Fat Embolism

Fig. 5 Graph showing the mean intraoperative values (and standard errors of the mean) of oxygen saturation (SaO2) during total hip arthroplasty, when all patients were receiving 100

percent inspired oxygen, in the three groups of patients.

ROCCO PAOLO PITTO et al. J Bone Joint Surg Am 1999;81:831-43

©1999 by The Journal of Bone and Joint Surgery, Inc.

Page 11: Comparison of Fixation of the Femoral Component without Cement and Fixation with Use of a Bone-Vacuum Cementing Technique for the Prevention of Fat Embolism

Fig. 6 Graph showing the mean levels (and standard error of the mean) of end tidal carbon dioxide (PetCO2) in the three groups of patients.

ROCCO PAOLO PITTO et al. J Bone Joint Surg Am 1999;81:831-43

©1999 by The Journal of Bone and Joint Surgery, Inc.

Page 12: Comparison of Fixation of the Femoral Component without Cement and Fixation with Use of a Bone-Vacuum Cementing Technique for the Prevention of Fat Embolism

Fig. 7 Graph showing the mean perioperative pulmonary shunt values in the three groups of patients.

ROCCO PAOLO PITTO et al. J Bone Joint Surg Am 1999;81:831-43

©1999 by The Journal of Bone and Joint Surgery, Inc.

Page 13: Comparison of Fixation of the Femoral Component without Cement and Fixation with Use of a Bone-Vacuum Cementing Technique for the Prevention of Fat Embolism

Fig. 8 Graph showing the mean perioperative pulmonary shunt values and the physical status of the sixty patients assessed according to the criteria of the American Society of

Anesthesiologists (ASA)1.

ROCCO PAOLO PITTO et al. J Bone Joint Surg Am 1999;81:831-43