compact/highly accurate actuator new product...

60
1 CC-848A LINEAR SLIDE CYLINDER LCM SERIES Linear slide cylinder Compact/highly accurate actuator LCM Series New product

Upload: haphuc

Post on 06-Jul-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

1CC-848A

LINEAR SLIDE CYLINDER LCM SERIES

Linear slide cylinderCompacthighly accurate actuator

LCM Series

New product

20 15 5 10

RoHS Directive-compliantSubstances adversely affecting the environment including lead and hexavalent chromium have been eliminated

Wide variationsAvailable variations include adjustable-stroke side installation and clean room specifications

Highly reliable stainless steel partsCorrosion-resistant stainless steel is used for the cylinder and slide table

Workpiece installation on either of two facesThe workpiece can be directly installed either on the table top or front using the installation holes provided

Compatible with small spaces This cylinder can be installed even in compact spacing making layout more flexible

Miniature size 2-color F type switch is now available

Ideal for high-accuracy positioning Highly accurate 0005 mm sliding parallelism and 003 mm installation parallelism are ensured making this actuator ideal for positioning

2-color switch installableHighly compact accurate and rigid LCM Series linear slide cylinder (oslash45 middot oslash6 middot oslash8)

Compact highly accurate actuator

LCM-P

LCM

Stroke length (mm)Bore size

Ф45 Ф6 Ф8 Ф45 Ф6 Ф8 Ф45 Ф6 Ф8

Ф45 Ф6 Ф8 Ф45 Ф6 Ф8

Double acting single rod type

Double acting stroke adjustable type (extended)

LCM-A

LCM-R Double acting stroke adjustable type (extendedretracted)

Double acting side installation type

LCM-P73 Double acting single rod type clean room specifications

Variation

Powerful designA linear guide with contacts at four points enables this cylinder to be used with loads in different directions

Ultimate pursuit of downsizing The cylinder linear guide and slide table have been integrated into a highly compact unit

Sliding parallelism

Installation parallelism

Switch rail

Actual size

10mm

18mm

43mm

LCM Series product

Table Guide

Cylinder

20 15 5 10

RoHS Directive-compliantSubstances adversely affecting the environment including lead and hexavalent chromium have been eliminated

Wide variationsAvailable variations include adjustable-stroke side installation and clean room specifications

Highly reliable stainless steel partsCorrosion-resistant stainless steel is used for the cylinder and slide table

Workpiece installation on either of two facesThe workpiece can be directly installed either on the table top or front using the installation holes provided

Compatible with small spaces This cylinder can be installed even in compact spacing making layout more flexible

Miniature size 2-color F type switch is now available

Ideal for high-accuracy positioning Highly accurate 0005 mm sliding parallelism and 003 mm installation parallelism are ensured making this actuator ideal for positioning

2-color switch installableHighly compact accurate and rigid LCM Series linear slide cylinder (oslash45 middot oslash6 middot oslash8)

Compact highly accurate actuator

LCM-P

LCM

Stroke length (mm)Bore size

Ф45 Ф6 Ф8 Ф45 Ф6 Ф8 Ф45 Ф6 Ф8

Ф45 Ф6 Ф8 Ф45 Ф6 Ф8

Double acting single rod type

Double acting stroke adjustable type (extended)

LCM-A

LCM-R Double acting stroke adjustable type (extendedretracted)

Double acting side installation type

LCM-P73 Double acting single rod type clean room specifications

Variation

Powerful designA linear guide with contacts at four points enables this cylinder to be used with loads in different directions

Ultimate pursuit of downsizing The cylinder linear guide and slide table have been integrated into a highly compact unit

Sliding parallelism

Installation parallelism

Switch rail

Actual size

10mm

18mm

43mm

LCM Series product

Table Guide

Cylinder

Intro

VariationModel no

JIS symbolBore size (mm)

Double acting single rod type

LCM Φ45

Φ6

Φ8

Double acting stroke adjustable type

(extended)

LCM-P Φ45

Φ6

Φ8

Double acting stroke adjustable type

(extendedretracted)

LCM-R Φ45

Φ6

Φ8

Double acting side installation type

LCM-A Φ45

Φ6

Φ8

Double acting single rod type clean room

specifications

LCM-P73 Φ45

Φ6

Φ8

Linear slide cylinder

LCM SeriesSeries variation

Specification tableLCMSeries

Intro

Standard Option Custom order Not available

Standard stroke length (mm)

Option

Switc

h

Page

With

buf

fer

With

mag

net

With

mag

net +

sw

itch

rail

Dow

el p

in a

ttach

ed

5 10 15 20 B M F J

9

7

39

Note Custom stroke length is not available

Intro 3

The safety cautions are ranked as DANGER WARNING and CAUTION in this section

DANGER When a dangerous situation may occur if handling is mistaken leading to fatal or serious injuries or when there is a high degree of emergency to a warning

WARNING When a dangerous situation may occur if handling is mistaken leading to fatal or serious injuries

CAUTION When a dangerous situation may occur if handling is mistaken leading to minor injuries or physical damage

Note that some items described as ldquoCAUTIONrdquo may lead to serious results depending on the situationIn any case important information that must be observed is explained

When designing and manufacturing a device using CKD products the manufacturer is obligated to check that device safety mechanical mechanism pneumatic control circuit or water control circuit and the system operated by electrical control that controls the devices is securedIt is important to select use handle and maintain the product appropriately to ensure that the CKD product is used safelyObserve warnings and precautions to ensure device safetyCheck that device safety is ensured and manufacture a safe device

Always read this section before starting use

Safety precautions

WARNING This product is designed and manufactured as a general industrial machine part It must be handled by an operator having sufficient knowledge and experience in handling Use this product in accordance of specificationsThis product must be used within its stated specifications It must not be modified or machinedThis product is intended for use as a general-purpose industrial device or part It is not intended for use outdoors or for use under the following conditions or environmentNote that this product can be used when CKD is consulted prior to use and the customer consents to CKD product specifications The customer must provide safety measures to avoid risks in the event of problems

Use for special applications requiring safety including nuclear energy railroad aviation ship vehicle medical equipment equipment or applications coming into contact with beverage or food amusement equipment emergency shutoff circuits press machine brake circuits or for safeguard

Use for applications where life or assets could be adversely affected and special safety measures are required

Do not handle pipe or remove devices before confirming safety Inspect and service the machine and devices after confirming safety of the entire system related to this product Note that there may be hot or charged sections even after operation is stopped When inspecting or servicing the device turn off the energy source (air supply or water supply) and turn off power to the facility Discharge any compressed air from the system and pay enough attention to possible water leakage and leakage of electricity

When starting or restarting a machine or device that incorporates pneumatic components make sure that the system safety such as pop-out prevention measures is secured

Observe warnings and cautions on the pages below to prevent accidents

Observe corporate standards and regulations etc related to the safety of device design and control etcISO 4414 JIS B 8370 (pneumatic system rules)JFPS 2008 (principles for pneumatic cylinder selection and use)High Pressure Gas Maintenance Law Occupational Safety and Sanitation Laws other safety rules body standards and regulations etc

1 CKD cannot be held liable for any business interruption loss of profit personal injury delay cost or any other ancillary or indirect loss cost or damage resulting from the use of or faults in the use of CKD products

2 CKD cannot be held responsible for the following damage (1) Damage resulting from failure of CKD parts due to fire from reasons not attributable to CKD or by intentional

or negligence of a third party or customer (2) When a CKD product is assembled into customer equipment damage that could have been avoided if

customer equipment were provided with functions and structure etc generally accepted in the industry (3) Damage resulting from use exceeding the scope of specifications provided in CKD catalogs or instruction

manuals etc or from actions not following precautions for installation adjustment or maintenance etc (4) Damage resulting from production modifications not approved by CKD or from faults due to combination with

other software or other connected devices

Disclaimer

Allowable load mass1000

100

100 01 02 03 04 06

Load

mas

s(g

)

05Max speed v (ms)

LCM-8

LCM-6

LCM-45

Intro 4

Pneumatic components

Design amp Selection

Always read this section before starting useRefer to Pneumatic cylinders (CB-029SA) general details on cylinders and cylinder switch

Safety precautions

Use the cylinder with the tolerable absorption or less shown below If dynamic energy exceeds this value consider using a separate shock absorber

1 Common

CAUTION

Installation amp Adjustment

1 Common Piping

When changing a piping port position apply adhesive to M3 plug (hexagon socket head set screw)(Low intensity adhesive such as LOCTITE 222 221 THREE BOND1344 recommended)Tighten the plug to where the bolt does not protrude from the port or contact the base of the port hole Applicable piping joints are limited so refer to the below table

Bore size Φ45 Φ6 Φ8

Allowable energy absorption J 159times10-3 283times10-3 502times10-3

Refer to the LCM Selection Guide on pages 47 and 48 when selecting the cylinder When using the cylinder where it could be subject to water or oil exposure where it could corrode or where high levels of dust are present the cylinder could be damaged or malfunction Protect the product with a cover Stainless steel is used for the body and slide table but rust could form depending on the environment Regularly apply an anticorrosion agent The switch could malfunction if used in an environment including magnetic fields Magnetic sources around the switch could also cause malfunction When attaching a magnetic workpiece to the slide table check that the workpiece does not extend toward the switch from the end of the table Exposing this product to a powerful magnet could magnetize the product and cause the switch to malfunction

Bore size Recommended joints

All bore sizes

PG-S2-M3PG-S2-M3-SPG-L2-M3FTS4-M3FTL4-M3

Recommended joints

The slide table and end plate are supported by balls When fixing the jig with bolts support the slide table and end plate before tightening If held and tightened excessive moment on the guide could decrease guide section accuracy

Avoid denting or scratches that could obstruct the parallelism of the cylinder installation face or slide table face Maintain parallelism of the installation mate at 002 mm or less If parallelism is poor guide section accuracy could decrease rolling resistance could increase and product life could be adversely affected

Use a loose-fitting stepped pin (option) for positioning A press-fit dimension pin could damage the guide due to the load in press-fitting and result in faults The pin hole is a through hole so if a pin other than a stepped pin is used the pin could interfere and result in faults

Note FTL4-M3 cannot be used for the φ45 clean room specification dust port

D E

F

A

B

LCMSeries

Intro 5

Installation amp Adjustment

Cylinder installation

Jig installation

Model no Applicable bolts

Max tightening torqueNm

Dmm

LCM--45 M2times04 032 35LCM--6 M25times045 065 5LCM--8 M25times045 065 55

Model no Applicable bolts

Max tightening torqueNm

Emm

LCM--45 M25times045 065 35LCM--6 M3times05 114 5LCM--8 M3times05 114 55

Model no Applicable bolts

Max tightening torqueNm

Max screw depthF mm

LCM--45 M2times04 032 25LCM--6 M25times045 065 25LCM--8 M3times05 114 3

Model no Applicable bolts

Max tightening torqueNm

Max screw depthA mm

Max screw depthB mm

LCM--45 M3times05 063 4 45LCM--6 M3times05 063 4 55LCM--8 M3times05 063 5 55

Note The work installation bolt must be shorter than the maximum screw depth If it is too long it could contact the body and break

This cylinder switch can be changed to one with a switch and the switch installation face can be changed The tightening torque of the bolt fixing the switch rail is given below The switch installation face port is not used so attach a plug before assembling the switch rail

Model no Applicable bolts

Max tightening torqueNm

LCM--45 M2times04 017LCM--6 M2times04 017LCM--8 M2times04 017

C

Note Do not use a washer etc The installation bolt could contact the guide and break

Model no Applicable bolts

Max tightening torqueNm

Cmm

LCM-A-45 M3times05 114 5LCM-A-6 M3times05 114 5LCM-A-8 M4times07 27 4

When installing a jig guide slide table or end plate observe the following values for bolt screw depth and tightening torque

Cylinder installation (side installation)

3mm or longer

Magneticsubstance

DB

A

C

3mm or longer

Magneticsubstance

DB

A

C

The cylinder may malfunction if a magnetic substance such as a steel plate is nearby Move the magnetic substance to at least 3 mm from the cylinder (Same clearance for all bore size)

The cylinder switch may malfunction if cylinders are installed adjacently Separate cylinders with maintaining these distances A B C and D = 3 mm or longer (Same clearance for all bore size)

A A A

LCMSeries

Intro 6

Care must be taken as the product can not be installed vertically if of the type with a buffer

2 Side installation type 3 With buffer

CAUTION

Interval larger than dimensions listed on the table below must be maintained if the side installation type is installed in parallel

During Use amp Maintenance

CAUTION

Apply CGL grease (Nippon Thompson) to the track rails tracks of the guide after six months of use or 3000000 operations whichever is sooner

Model no A mmLCM-A-45 LCM-A-6 14LCM-A-8 16

Installation amp Adjustment

JIS symbol

Linear slide cylinder double acting single rod type

LCM Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCMBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCMSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 42 46 42 46 - - - - 3 10Φ6 58 63 58 63 66 7 - - 4 10Φ8 83 88 83 88 104 110 104 110 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCMSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM J2

R R6 10 J2LCM F2H

4

LCMSeriesHow to order

Dowel pin

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

J 45 LCM

Pin number

5

LCMSeries

Internal structure and parts list

LCM-45bull LCM-68bull

LCM-45 to 8 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel Guard Acetar resin Bolt Stainless steel 3 Stop plate Stainless steel3 End plate Aluminum alloy 14 Machine screw Stainless steel4 O ring Nitrile rubber 15 Floating bush B Stainless steel5 Rod cover Acetar resin 16 Cushion rubber Urethane rubber (Φ6 Φ8)6 Rod packing seal Nitrile rubber 7 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 18 Switch rail Aluminum alloy8 Slide table Stainless steel 9 Plate Aluminum alloy9 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel

10 Piston packing seal Nitrile rubber Magnet Plastic O ring Nitrile rubber Dowel pin Steel

6

LCMSeriesInternal structure and parts list

Internal structure and parts list

LCM-45 to 8 with bufferbull

Parts listNo Parts name Material Remarks

End plate Aluminum alloy Floating bush A Stainless steel3 Floating bush B Stainless steel4 Spring holder Copper alloy5 Coil spring Stainless steel

115 16 2-M3 x 05L side piping port (Note 1)

3

10

94

652-M3 x 05 depth 45

18 3

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42 ()

16

4

Φ3

+00

3 0

dept

h 1

8 05

4 55

9

3

7 16 4-Φ21

4-42 2-M2 x 04 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05R side piping port (Note 1)

235 32

1

32

35

3

115 16

3 28

Φ3 +003 0 depth 254-M25 x 045 depth 35 7 16

Φ3 +003 0

depth 25

8 34

45 15

3

35

7 Φ4h

7 0 -0

012

25 18

Φ3-0

002

-00

14

95

65 8 34115

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 52 () 16

4

3

7 16 4-Φ214-42

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

21

2-M3 x 05 depth 6(If two switches installed) (If one switch installed)

95

7

LCMSeries

Dimensions

LCM-45bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

45

112

72-M3 x 05 depth 55

14 20 14

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A ()

B

4

Φ3

+00

3 0

dept

h 1

8 05

4 75

3

7 C 4-Φ26

4-5 2-M25 x 045 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

21

32

45 E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

14 95

95

115 9 H

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 I () B

4

14

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)

J 14

99

21

2-M3 x 05 depth 6

8

LCMSeriesDimensions

LCM-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dimensions

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 49 30 34 40 40 59 40

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

5

14

125

82-M3 x 05 depth 55

16 24 18

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A ()

B

4

Φ3

+00

3 0

dept

h 2

8

05

5 85

14

4

7 C 4-Φ26

4-5 2-M3 x 05 depth 3

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

34 5

E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

18 35

5

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

95

114 9 H09

Φ3

+00

3 0

dept

h 2

8Φ3 +003 0 depth 28

4-M3 x 05 depth 5I ()

B4

18

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

3

(Note 1) Plugs are assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

9

LCMSeries

Dimensions

LCM-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 54 26 26 35 26 39 45 45 64 4520 54 26 26 35 26 39 45 45 64 45

10

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extended)

LCM-P SeriesBore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-PBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion NoneLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range mm -5 to 0Repeat position accuracy mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCM-PSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 49 53 49 53 - - - - 3 10Φ6 68 73 68 73 77 83 - - 4 10Φ8 97 102 97 102 120 126 120 126 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 2: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

20 15 5 10

RoHS Directive-compliantSubstances adversely affecting the environment including lead and hexavalent chromium have been eliminated

Wide variationsAvailable variations include adjustable-stroke side installation and clean room specifications

Highly reliable stainless steel partsCorrosion-resistant stainless steel is used for the cylinder and slide table

Workpiece installation on either of two facesThe workpiece can be directly installed either on the table top or front using the installation holes provided

Compatible with small spaces This cylinder can be installed even in compact spacing making layout more flexible

Miniature size 2-color F type switch is now available

Ideal for high-accuracy positioning Highly accurate 0005 mm sliding parallelism and 003 mm installation parallelism are ensured making this actuator ideal for positioning

2-color switch installableHighly compact accurate and rigid LCM Series linear slide cylinder (oslash45 middot oslash6 middot oslash8)

Compact highly accurate actuator

LCM-P

LCM

Stroke length (mm)Bore size

Ф45 Ф6 Ф8 Ф45 Ф6 Ф8 Ф45 Ф6 Ф8

Ф45 Ф6 Ф8 Ф45 Ф6 Ф8

Double acting single rod type

Double acting stroke adjustable type (extended)

LCM-A

LCM-R Double acting stroke adjustable type (extendedretracted)

Double acting side installation type

LCM-P73 Double acting single rod type clean room specifications

Variation

Powerful designA linear guide with contacts at four points enables this cylinder to be used with loads in different directions

Ultimate pursuit of downsizing The cylinder linear guide and slide table have been integrated into a highly compact unit

Sliding parallelism

Installation parallelism

Switch rail

Actual size

10mm

18mm

43mm

LCM Series product

Table Guide

Cylinder

20 15 5 10

RoHS Directive-compliantSubstances adversely affecting the environment including lead and hexavalent chromium have been eliminated

Wide variationsAvailable variations include adjustable-stroke side installation and clean room specifications

Highly reliable stainless steel partsCorrosion-resistant stainless steel is used for the cylinder and slide table

Workpiece installation on either of two facesThe workpiece can be directly installed either on the table top or front using the installation holes provided

Compatible with small spaces This cylinder can be installed even in compact spacing making layout more flexible

Miniature size 2-color F type switch is now available

Ideal for high-accuracy positioning Highly accurate 0005 mm sliding parallelism and 003 mm installation parallelism are ensured making this actuator ideal for positioning

2-color switch installableHighly compact accurate and rigid LCM Series linear slide cylinder (oslash45 middot oslash6 middot oslash8)

Compact highly accurate actuator

LCM-P

LCM

Stroke length (mm)Bore size

Ф45 Ф6 Ф8 Ф45 Ф6 Ф8 Ф45 Ф6 Ф8

Ф45 Ф6 Ф8 Ф45 Ф6 Ф8

Double acting single rod type

Double acting stroke adjustable type (extended)

LCM-A

LCM-R Double acting stroke adjustable type (extendedretracted)

Double acting side installation type

LCM-P73 Double acting single rod type clean room specifications

Variation

Powerful designA linear guide with contacts at four points enables this cylinder to be used with loads in different directions

Ultimate pursuit of downsizing The cylinder linear guide and slide table have been integrated into a highly compact unit

Sliding parallelism

Installation parallelism

Switch rail

Actual size

10mm

18mm

43mm

LCM Series product

Table Guide

Cylinder

Intro

VariationModel no

JIS symbolBore size (mm)

Double acting single rod type

LCM Φ45

Φ6

Φ8

Double acting stroke adjustable type

(extended)

LCM-P Φ45

Φ6

Φ8

Double acting stroke adjustable type

(extendedretracted)

LCM-R Φ45

Φ6

Φ8

Double acting side installation type

LCM-A Φ45

Φ6

Φ8

Double acting single rod type clean room

specifications

LCM-P73 Φ45

Φ6

Φ8

Linear slide cylinder

LCM SeriesSeries variation

Specification tableLCMSeries

Intro

Standard Option Custom order Not available

Standard stroke length (mm)

Option

Switc

h

Page

With

buf

fer

With

mag

net

With

mag

net +

sw

itch

rail

Dow

el p

in a

ttach

ed

5 10 15 20 B M F J

9

7

39

Note Custom stroke length is not available

Intro 3

The safety cautions are ranked as DANGER WARNING and CAUTION in this section

DANGER When a dangerous situation may occur if handling is mistaken leading to fatal or serious injuries or when there is a high degree of emergency to a warning

WARNING When a dangerous situation may occur if handling is mistaken leading to fatal or serious injuries

CAUTION When a dangerous situation may occur if handling is mistaken leading to minor injuries or physical damage

Note that some items described as ldquoCAUTIONrdquo may lead to serious results depending on the situationIn any case important information that must be observed is explained

When designing and manufacturing a device using CKD products the manufacturer is obligated to check that device safety mechanical mechanism pneumatic control circuit or water control circuit and the system operated by electrical control that controls the devices is securedIt is important to select use handle and maintain the product appropriately to ensure that the CKD product is used safelyObserve warnings and precautions to ensure device safetyCheck that device safety is ensured and manufacture a safe device

Always read this section before starting use

Safety precautions

WARNING This product is designed and manufactured as a general industrial machine part It must be handled by an operator having sufficient knowledge and experience in handling Use this product in accordance of specificationsThis product must be used within its stated specifications It must not be modified or machinedThis product is intended for use as a general-purpose industrial device or part It is not intended for use outdoors or for use under the following conditions or environmentNote that this product can be used when CKD is consulted prior to use and the customer consents to CKD product specifications The customer must provide safety measures to avoid risks in the event of problems

Use for special applications requiring safety including nuclear energy railroad aviation ship vehicle medical equipment equipment or applications coming into contact with beverage or food amusement equipment emergency shutoff circuits press machine brake circuits or for safeguard

Use for applications where life or assets could be adversely affected and special safety measures are required

Do not handle pipe or remove devices before confirming safety Inspect and service the machine and devices after confirming safety of the entire system related to this product Note that there may be hot or charged sections even after operation is stopped When inspecting or servicing the device turn off the energy source (air supply or water supply) and turn off power to the facility Discharge any compressed air from the system and pay enough attention to possible water leakage and leakage of electricity

When starting or restarting a machine or device that incorporates pneumatic components make sure that the system safety such as pop-out prevention measures is secured

Observe warnings and cautions on the pages below to prevent accidents

Observe corporate standards and regulations etc related to the safety of device design and control etcISO 4414 JIS B 8370 (pneumatic system rules)JFPS 2008 (principles for pneumatic cylinder selection and use)High Pressure Gas Maintenance Law Occupational Safety and Sanitation Laws other safety rules body standards and regulations etc

1 CKD cannot be held liable for any business interruption loss of profit personal injury delay cost or any other ancillary or indirect loss cost or damage resulting from the use of or faults in the use of CKD products

2 CKD cannot be held responsible for the following damage (1) Damage resulting from failure of CKD parts due to fire from reasons not attributable to CKD or by intentional

or negligence of a third party or customer (2) When a CKD product is assembled into customer equipment damage that could have been avoided if

customer equipment were provided with functions and structure etc generally accepted in the industry (3) Damage resulting from use exceeding the scope of specifications provided in CKD catalogs or instruction

manuals etc or from actions not following precautions for installation adjustment or maintenance etc (4) Damage resulting from production modifications not approved by CKD or from faults due to combination with

other software or other connected devices

Disclaimer

Allowable load mass1000

100

100 01 02 03 04 06

Load

mas

s(g

)

05Max speed v (ms)

LCM-8

LCM-6

LCM-45

Intro 4

Pneumatic components

Design amp Selection

Always read this section before starting useRefer to Pneumatic cylinders (CB-029SA) general details on cylinders and cylinder switch

Safety precautions

Use the cylinder with the tolerable absorption or less shown below If dynamic energy exceeds this value consider using a separate shock absorber

1 Common

CAUTION

Installation amp Adjustment

1 Common Piping

When changing a piping port position apply adhesive to M3 plug (hexagon socket head set screw)(Low intensity adhesive such as LOCTITE 222 221 THREE BOND1344 recommended)Tighten the plug to where the bolt does not protrude from the port or contact the base of the port hole Applicable piping joints are limited so refer to the below table

Bore size Φ45 Φ6 Φ8

Allowable energy absorption J 159times10-3 283times10-3 502times10-3

Refer to the LCM Selection Guide on pages 47 and 48 when selecting the cylinder When using the cylinder where it could be subject to water or oil exposure where it could corrode or where high levels of dust are present the cylinder could be damaged or malfunction Protect the product with a cover Stainless steel is used for the body and slide table but rust could form depending on the environment Regularly apply an anticorrosion agent The switch could malfunction if used in an environment including magnetic fields Magnetic sources around the switch could also cause malfunction When attaching a magnetic workpiece to the slide table check that the workpiece does not extend toward the switch from the end of the table Exposing this product to a powerful magnet could magnetize the product and cause the switch to malfunction

Bore size Recommended joints

All bore sizes

PG-S2-M3PG-S2-M3-SPG-L2-M3FTS4-M3FTL4-M3

Recommended joints

The slide table and end plate are supported by balls When fixing the jig with bolts support the slide table and end plate before tightening If held and tightened excessive moment on the guide could decrease guide section accuracy

Avoid denting or scratches that could obstruct the parallelism of the cylinder installation face or slide table face Maintain parallelism of the installation mate at 002 mm or less If parallelism is poor guide section accuracy could decrease rolling resistance could increase and product life could be adversely affected

Use a loose-fitting stepped pin (option) for positioning A press-fit dimension pin could damage the guide due to the load in press-fitting and result in faults The pin hole is a through hole so if a pin other than a stepped pin is used the pin could interfere and result in faults

Note FTL4-M3 cannot be used for the φ45 clean room specification dust port

D E

F

A

B

LCMSeries

Intro 5

Installation amp Adjustment

Cylinder installation

Jig installation

Model no Applicable bolts

Max tightening torqueNm

Dmm

LCM--45 M2times04 032 35LCM--6 M25times045 065 5LCM--8 M25times045 065 55

Model no Applicable bolts

Max tightening torqueNm

Emm

LCM--45 M25times045 065 35LCM--6 M3times05 114 5LCM--8 M3times05 114 55

Model no Applicable bolts

Max tightening torqueNm

Max screw depthF mm

LCM--45 M2times04 032 25LCM--6 M25times045 065 25LCM--8 M3times05 114 3

Model no Applicable bolts

Max tightening torqueNm

Max screw depthA mm

Max screw depthB mm

LCM--45 M3times05 063 4 45LCM--6 M3times05 063 4 55LCM--8 M3times05 063 5 55

Note The work installation bolt must be shorter than the maximum screw depth If it is too long it could contact the body and break

This cylinder switch can be changed to one with a switch and the switch installation face can be changed The tightening torque of the bolt fixing the switch rail is given below The switch installation face port is not used so attach a plug before assembling the switch rail

Model no Applicable bolts

Max tightening torqueNm

LCM--45 M2times04 017LCM--6 M2times04 017LCM--8 M2times04 017

C

Note Do not use a washer etc The installation bolt could contact the guide and break

Model no Applicable bolts

Max tightening torqueNm

Cmm

LCM-A-45 M3times05 114 5LCM-A-6 M3times05 114 5LCM-A-8 M4times07 27 4

When installing a jig guide slide table or end plate observe the following values for bolt screw depth and tightening torque

Cylinder installation (side installation)

3mm or longer

Magneticsubstance

DB

A

C

3mm or longer

Magneticsubstance

DB

A

C

The cylinder may malfunction if a magnetic substance such as a steel plate is nearby Move the magnetic substance to at least 3 mm from the cylinder (Same clearance for all bore size)

The cylinder switch may malfunction if cylinders are installed adjacently Separate cylinders with maintaining these distances A B C and D = 3 mm or longer (Same clearance for all bore size)

A A A

LCMSeries

Intro 6

Care must be taken as the product can not be installed vertically if of the type with a buffer

2 Side installation type 3 With buffer

CAUTION

Interval larger than dimensions listed on the table below must be maintained if the side installation type is installed in parallel

During Use amp Maintenance

CAUTION

Apply CGL grease (Nippon Thompson) to the track rails tracks of the guide after six months of use or 3000000 operations whichever is sooner

Model no A mmLCM-A-45 LCM-A-6 14LCM-A-8 16

Installation amp Adjustment

JIS symbol

Linear slide cylinder double acting single rod type

LCM Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCMBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCMSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 42 46 42 46 - - - - 3 10Φ6 58 63 58 63 66 7 - - 4 10Φ8 83 88 83 88 104 110 104 110 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCMSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM J2

R R6 10 J2LCM F2H

4

LCMSeriesHow to order

Dowel pin

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

J 45 LCM

Pin number

5

LCMSeries

Internal structure and parts list

LCM-45bull LCM-68bull

LCM-45 to 8 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel Guard Acetar resin Bolt Stainless steel 3 Stop plate Stainless steel3 End plate Aluminum alloy 14 Machine screw Stainless steel4 O ring Nitrile rubber 15 Floating bush B Stainless steel5 Rod cover Acetar resin 16 Cushion rubber Urethane rubber (Φ6 Φ8)6 Rod packing seal Nitrile rubber 7 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 18 Switch rail Aluminum alloy8 Slide table Stainless steel 9 Plate Aluminum alloy9 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel

10 Piston packing seal Nitrile rubber Magnet Plastic O ring Nitrile rubber Dowel pin Steel

6

LCMSeriesInternal structure and parts list

Internal structure and parts list

LCM-45 to 8 with bufferbull

Parts listNo Parts name Material Remarks

End plate Aluminum alloy Floating bush A Stainless steel3 Floating bush B Stainless steel4 Spring holder Copper alloy5 Coil spring Stainless steel

115 16 2-M3 x 05L side piping port (Note 1)

3

10

94

652-M3 x 05 depth 45

18 3

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42 ()

16

4

Φ3

+00

3 0

dept

h 1

8 05

4 55

9

3

7 16 4-Φ21

4-42 2-M2 x 04 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05R side piping port (Note 1)

235 32

1

32

35

3

115 16

3 28

Φ3 +003 0 depth 254-M25 x 045 depth 35 7 16

Φ3 +003 0

depth 25

8 34

45 15

3

35

7 Φ4h

7 0 -0

012

25 18

Φ3-0

002

-00

14

95

65 8 34115

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 52 () 16

4

3

7 16 4-Φ214-42

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

21

2-M3 x 05 depth 6(If two switches installed) (If one switch installed)

95

7

LCMSeries

Dimensions

LCM-45bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

45

112

72-M3 x 05 depth 55

14 20 14

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A ()

B

4

Φ3

+00

3 0

dept

h 1

8 05

4 75

3

7 C 4-Φ26

4-5 2-M25 x 045 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

21

32

45 E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

14 95

95

115 9 H

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 I () B

4

14

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)

J 14

99

21

2-M3 x 05 depth 6

8

LCMSeriesDimensions

LCM-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dimensions

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 49 30 34 40 40 59 40

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

5

14

125

82-M3 x 05 depth 55

16 24 18

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A ()

B

4

Φ3

+00

3 0

dept

h 2

8

05

5 85

14

4

7 C 4-Φ26

4-5 2-M3 x 05 depth 3

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

34 5

E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

18 35

5

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

95

114 9 H09

Φ3

+00

3 0

dept

h 2

8Φ3 +003 0 depth 28

4-M3 x 05 depth 5I ()

B4

18

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

3

(Note 1) Plugs are assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

9

LCMSeries

Dimensions

LCM-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 54 26 26 35 26 39 45 45 64 4520 54 26 26 35 26 39 45 45 64 45

10

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extended)

LCM-P SeriesBore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-PBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion NoneLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range mm -5 to 0Repeat position accuracy mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCM-PSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 49 53 49 53 - - - - 3 10Φ6 68 73 68 73 77 83 - - 4 10Φ8 97 102 97 102 120 126 120 126 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 3: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

20 15 5 10

RoHS Directive-compliantSubstances adversely affecting the environment including lead and hexavalent chromium have been eliminated

Wide variationsAvailable variations include adjustable-stroke side installation and clean room specifications

Highly reliable stainless steel partsCorrosion-resistant stainless steel is used for the cylinder and slide table

Workpiece installation on either of two facesThe workpiece can be directly installed either on the table top or front using the installation holes provided

Compatible with small spaces This cylinder can be installed even in compact spacing making layout more flexible

Miniature size 2-color F type switch is now available

Ideal for high-accuracy positioning Highly accurate 0005 mm sliding parallelism and 003 mm installation parallelism are ensured making this actuator ideal for positioning

2-color switch installableHighly compact accurate and rigid LCM Series linear slide cylinder (oslash45 middot oslash6 middot oslash8)

Compact highly accurate actuator

LCM-P

LCM

Stroke length (mm)Bore size

Ф45 Ф6 Ф8 Ф45 Ф6 Ф8 Ф45 Ф6 Ф8

Ф45 Ф6 Ф8 Ф45 Ф6 Ф8

Double acting single rod type

Double acting stroke adjustable type (extended)

LCM-A

LCM-R Double acting stroke adjustable type (extendedretracted)

Double acting side installation type

LCM-P73 Double acting single rod type clean room specifications

Variation

Powerful designA linear guide with contacts at four points enables this cylinder to be used with loads in different directions

Ultimate pursuit of downsizing The cylinder linear guide and slide table have been integrated into a highly compact unit

Sliding parallelism

Installation parallelism

Switch rail

Actual size

10mm

18mm

43mm

LCM Series product

Table Guide

Cylinder

Intro

VariationModel no

JIS symbolBore size (mm)

Double acting single rod type

LCM Φ45

Φ6

Φ8

Double acting stroke adjustable type

(extended)

LCM-P Φ45

Φ6

Φ8

Double acting stroke adjustable type

(extendedretracted)

LCM-R Φ45

Φ6

Φ8

Double acting side installation type

LCM-A Φ45

Φ6

Φ8

Double acting single rod type clean room

specifications

LCM-P73 Φ45

Φ6

Φ8

Linear slide cylinder

LCM SeriesSeries variation

Specification tableLCMSeries

Intro

Standard Option Custom order Not available

Standard stroke length (mm)

Option

Switc

h

Page

With

buf

fer

With

mag

net

With

mag

net +

sw

itch

rail

Dow

el p

in a

ttach

ed

5 10 15 20 B M F J

9

7

39

Note Custom stroke length is not available

Intro 3

The safety cautions are ranked as DANGER WARNING and CAUTION in this section

DANGER When a dangerous situation may occur if handling is mistaken leading to fatal or serious injuries or when there is a high degree of emergency to a warning

WARNING When a dangerous situation may occur if handling is mistaken leading to fatal or serious injuries

CAUTION When a dangerous situation may occur if handling is mistaken leading to minor injuries or physical damage

Note that some items described as ldquoCAUTIONrdquo may lead to serious results depending on the situationIn any case important information that must be observed is explained

When designing and manufacturing a device using CKD products the manufacturer is obligated to check that device safety mechanical mechanism pneumatic control circuit or water control circuit and the system operated by electrical control that controls the devices is securedIt is important to select use handle and maintain the product appropriately to ensure that the CKD product is used safelyObserve warnings and precautions to ensure device safetyCheck that device safety is ensured and manufacture a safe device

Always read this section before starting use

Safety precautions

WARNING This product is designed and manufactured as a general industrial machine part It must be handled by an operator having sufficient knowledge and experience in handling Use this product in accordance of specificationsThis product must be used within its stated specifications It must not be modified or machinedThis product is intended for use as a general-purpose industrial device or part It is not intended for use outdoors or for use under the following conditions or environmentNote that this product can be used when CKD is consulted prior to use and the customer consents to CKD product specifications The customer must provide safety measures to avoid risks in the event of problems

Use for special applications requiring safety including nuclear energy railroad aviation ship vehicle medical equipment equipment or applications coming into contact with beverage or food amusement equipment emergency shutoff circuits press machine brake circuits or for safeguard

Use for applications where life or assets could be adversely affected and special safety measures are required

Do not handle pipe or remove devices before confirming safety Inspect and service the machine and devices after confirming safety of the entire system related to this product Note that there may be hot or charged sections even after operation is stopped When inspecting or servicing the device turn off the energy source (air supply or water supply) and turn off power to the facility Discharge any compressed air from the system and pay enough attention to possible water leakage and leakage of electricity

When starting or restarting a machine or device that incorporates pneumatic components make sure that the system safety such as pop-out prevention measures is secured

Observe warnings and cautions on the pages below to prevent accidents

Observe corporate standards and regulations etc related to the safety of device design and control etcISO 4414 JIS B 8370 (pneumatic system rules)JFPS 2008 (principles for pneumatic cylinder selection and use)High Pressure Gas Maintenance Law Occupational Safety and Sanitation Laws other safety rules body standards and regulations etc

1 CKD cannot be held liable for any business interruption loss of profit personal injury delay cost or any other ancillary or indirect loss cost or damage resulting from the use of or faults in the use of CKD products

2 CKD cannot be held responsible for the following damage (1) Damage resulting from failure of CKD parts due to fire from reasons not attributable to CKD or by intentional

or negligence of a third party or customer (2) When a CKD product is assembled into customer equipment damage that could have been avoided if

customer equipment were provided with functions and structure etc generally accepted in the industry (3) Damage resulting from use exceeding the scope of specifications provided in CKD catalogs or instruction

manuals etc or from actions not following precautions for installation adjustment or maintenance etc (4) Damage resulting from production modifications not approved by CKD or from faults due to combination with

other software or other connected devices

Disclaimer

Allowable load mass1000

100

100 01 02 03 04 06

Load

mas

s(g

)

05Max speed v (ms)

LCM-8

LCM-6

LCM-45

Intro 4

Pneumatic components

Design amp Selection

Always read this section before starting useRefer to Pneumatic cylinders (CB-029SA) general details on cylinders and cylinder switch

Safety precautions

Use the cylinder with the tolerable absorption or less shown below If dynamic energy exceeds this value consider using a separate shock absorber

1 Common

CAUTION

Installation amp Adjustment

1 Common Piping

When changing a piping port position apply adhesive to M3 plug (hexagon socket head set screw)(Low intensity adhesive such as LOCTITE 222 221 THREE BOND1344 recommended)Tighten the plug to where the bolt does not protrude from the port or contact the base of the port hole Applicable piping joints are limited so refer to the below table

Bore size Φ45 Φ6 Φ8

Allowable energy absorption J 159times10-3 283times10-3 502times10-3

Refer to the LCM Selection Guide on pages 47 and 48 when selecting the cylinder When using the cylinder where it could be subject to water or oil exposure where it could corrode or where high levels of dust are present the cylinder could be damaged or malfunction Protect the product with a cover Stainless steel is used for the body and slide table but rust could form depending on the environment Regularly apply an anticorrosion agent The switch could malfunction if used in an environment including magnetic fields Magnetic sources around the switch could also cause malfunction When attaching a magnetic workpiece to the slide table check that the workpiece does not extend toward the switch from the end of the table Exposing this product to a powerful magnet could magnetize the product and cause the switch to malfunction

Bore size Recommended joints

All bore sizes

PG-S2-M3PG-S2-M3-SPG-L2-M3FTS4-M3FTL4-M3

Recommended joints

The slide table and end plate are supported by balls When fixing the jig with bolts support the slide table and end plate before tightening If held and tightened excessive moment on the guide could decrease guide section accuracy

Avoid denting or scratches that could obstruct the parallelism of the cylinder installation face or slide table face Maintain parallelism of the installation mate at 002 mm or less If parallelism is poor guide section accuracy could decrease rolling resistance could increase and product life could be adversely affected

Use a loose-fitting stepped pin (option) for positioning A press-fit dimension pin could damage the guide due to the load in press-fitting and result in faults The pin hole is a through hole so if a pin other than a stepped pin is used the pin could interfere and result in faults

Note FTL4-M3 cannot be used for the φ45 clean room specification dust port

D E

F

A

B

LCMSeries

Intro 5

Installation amp Adjustment

Cylinder installation

Jig installation

Model no Applicable bolts

Max tightening torqueNm

Dmm

LCM--45 M2times04 032 35LCM--6 M25times045 065 5LCM--8 M25times045 065 55

Model no Applicable bolts

Max tightening torqueNm

Emm

LCM--45 M25times045 065 35LCM--6 M3times05 114 5LCM--8 M3times05 114 55

Model no Applicable bolts

Max tightening torqueNm

Max screw depthF mm

LCM--45 M2times04 032 25LCM--6 M25times045 065 25LCM--8 M3times05 114 3

Model no Applicable bolts

Max tightening torqueNm

Max screw depthA mm

Max screw depthB mm

LCM--45 M3times05 063 4 45LCM--6 M3times05 063 4 55LCM--8 M3times05 063 5 55

Note The work installation bolt must be shorter than the maximum screw depth If it is too long it could contact the body and break

This cylinder switch can be changed to one with a switch and the switch installation face can be changed The tightening torque of the bolt fixing the switch rail is given below The switch installation face port is not used so attach a plug before assembling the switch rail

Model no Applicable bolts

Max tightening torqueNm

LCM--45 M2times04 017LCM--6 M2times04 017LCM--8 M2times04 017

C

Note Do not use a washer etc The installation bolt could contact the guide and break

Model no Applicable bolts

Max tightening torqueNm

Cmm

LCM-A-45 M3times05 114 5LCM-A-6 M3times05 114 5LCM-A-8 M4times07 27 4

When installing a jig guide slide table or end plate observe the following values for bolt screw depth and tightening torque

Cylinder installation (side installation)

3mm or longer

Magneticsubstance

DB

A

C

3mm or longer

Magneticsubstance

DB

A

C

The cylinder may malfunction if a magnetic substance such as a steel plate is nearby Move the magnetic substance to at least 3 mm from the cylinder (Same clearance for all bore size)

The cylinder switch may malfunction if cylinders are installed adjacently Separate cylinders with maintaining these distances A B C and D = 3 mm or longer (Same clearance for all bore size)

A A A

LCMSeries

Intro 6

Care must be taken as the product can not be installed vertically if of the type with a buffer

2 Side installation type 3 With buffer

CAUTION

Interval larger than dimensions listed on the table below must be maintained if the side installation type is installed in parallel

During Use amp Maintenance

CAUTION

Apply CGL grease (Nippon Thompson) to the track rails tracks of the guide after six months of use or 3000000 operations whichever is sooner

Model no A mmLCM-A-45 LCM-A-6 14LCM-A-8 16

Installation amp Adjustment

JIS symbol

Linear slide cylinder double acting single rod type

LCM Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCMBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCMSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 42 46 42 46 - - - - 3 10Φ6 58 63 58 63 66 7 - - 4 10Φ8 83 88 83 88 104 110 104 110 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCMSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM J2

R R6 10 J2LCM F2H

4

LCMSeriesHow to order

Dowel pin

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

J 45 LCM

Pin number

5

LCMSeries

Internal structure and parts list

LCM-45bull LCM-68bull

LCM-45 to 8 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel Guard Acetar resin Bolt Stainless steel 3 Stop plate Stainless steel3 End plate Aluminum alloy 14 Machine screw Stainless steel4 O ring Nitrile rubber 15 Floating bush B Stainless steel5 Rod cover Acetar resin 16 Cushion rubber Urethane rubber (Φ6 Φ8)6 Rod packing seal Nitrile rubber 7 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 18 Switch rail Aluminum alloy8 Slide table Stainless steel 9 Plate Aluminum alloy9 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel

10 Piston packing seal Nitrile rubber Magnet Plastic O ring Nitrile rubber Dowel pin Steel

6

LCMSeriesInternal structure and parts list

Internal structure and parts list

LCM-45 to 8 with bufferbull

Parts listNo Parts name Material Remarks

End plate Aluminum alloy Floating bush A Stainless steel3 Floating bush B Stainless steel4 Spring holder Copper alloy5 Coil spring Stainless steel

115 16 2-M3 x 05L side piping port (Note 1)

3

10

94

652-M3 x 05 depth 45

18 3

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42 ()

16

4

Φ3

+00

3 0

dept

h 1

8 05

4 55

9

3

7 16 4-Φ21

4-42 2-M2 x 04 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05R side piping port (Note 1)

235 32

1

32

35

3

115 16

3 28

Φ3 +003 0 depth 254-M25 x 045 depth 35 7 16

Φ3 +003 0

depth 25

8 34

45 15

3

35

7 Φ4h

7 0 -0

012

25 18

Φ3-0

002

-00

14

95

65 8 34115

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 52 () 16

4

3

7 16 4-Φ214-42

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

21

2-M3 x 05 depth 6(If two switches installed) (If one switch installed)

95

7

LCMSeries

Dimensions

LCM-45bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

45

112

72-M3 x 05 depth 55

14 20 14

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A ()

B

4

Φ3

+00

3 0

dept

h 1

8 05

4 75

3

7 C 4-Φ26

4-5 2-M25 x 045 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

21

32

45 E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

14 95

95

115 9 H

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 I () B

4

14

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)

J 14

99

21

2-M3 x 05 depth 6

8

LCMSeriesDimensions

LCM-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dimensions

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 49 30 34 40 40 59 40

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

5

14

125

82-M3 x 05 depth 55

16 24 18

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A ()

B

4

Φ3

+00

3 0

dept

h 2

8

05

5 85

14

4

7 C 4-Φ26

4-5 2-M3 x 05 depth 3

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

34 5

E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

18 35

5

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

95

114 9 H09

Φ3

+00

3 0

dept

h 2

8Φ3 +003 0 depth 28

4-M3 x 05 depth 5I ()

B4

18

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

3

(Note 1) Plugs are assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

9

LCMSeries

Dimensions

LCM-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 54 26 26 35 26 39 45 45 64 4520 54 26 26 35 26 39 45 45 64 45

10

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extended)

LCM-P SeriesBore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-PBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion NoneLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range mm -5 to 0Repeat position accuracy mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCM-PSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 49 53 49 53 - - - - 3 10Φ6 68 73 68 73 77 83 - - 4 10Φ8 97 102 97 102 120 126 120 126 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 4: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

Intro

VariationModel no

JIS symbolBore size (mm)

Double acting single rod type

LCM Φ45

Φ6

Φ8

Double acting stroke adjustable type

(extended)

LCM-P Φ45

Φ6

Φ8

Double acting stroke adjustable type

(extendedretracted)

LCM-R Φ45

Φ6

Φ8

Double acting side installation type

LCM-A Φ45

Φ6

Φ8

Double acting single rod type clean room

specifications

LCM-P73 Φ45

Φ6

Φ8

Linear slide cylinder

LCM SeriesSeries variation

Specification tableLCMSeries

Intro

Standard Option Custom order Not available

Standard stroke length (mm)

Option

Switc

h

Page

With

buf

fer

With

mag

net

With

mag

net +

sw

itch

rail

Dow

el p

in a

ttach

ed

5 10 15 20 B M F J

9

7

39

Note Custom stroke length is not available

Intro 3

The safety cautions are ranked as DANGER WARNING and CAUTION in this section

DANGER When a dangerous situation may occur if handling is mistaken leading to fatal or serious injuries or when there is a high degree of emergency to a warning

WARNING When a dangerous situation may occur if handling is mistaken leading to fatal or serious injuries

CAUTION When a dangerous situation may occur if handling is mistaken leading to minor injuries or physical damage

Note that some items described as ldquoCAUTIONrdquo may lead to serious results depending on the situationIn any case important information that must be observed is explained

When designing and manufacturing a device using CKD products the manufacturer is obligated to check that device safety mechanical mechanism pneumatic control circuit or water control circuit and the system operated by electrical control that controls the devices is securedIt is important to select use handle and maintain the product appropriately to ensure that the CKD product is used safelyObserve warnings and precautions to ensure device safetyCheck that device safety is ensured and manufacture a safe device

Always read this section before starting use

Safety precautions

WARNING This product is designed and manufactured as a general industrial machine part It must be handled by an operator having sufficient knowledge and experience in handling Use this product in accordance of specificationsThis product must be used within its stated specifications It must not be modified or machinedThis product is intended for use as a general-purpose industrial device or part It is not intended for use outdoors or for use under the following conditions or environmentNote that this product can be used when CKD is consulted prior to use and the customer consents to CKD product specifications The customer must provide safety measures to avoid risks in the event of problems

Use for special applications requiring safety including nuclear energy railroad aviation ship vehicle medical equipment equipment or applications coming into contact with beverage or food amusement equipment emergency shutoff circuits press machine brake circuits or for safeguard

Use for applications where life or assets could be adversely affected and special safety measures are required

Do not handle pipe or remove devices before confirming safety Inspect and service the machine and devices after confirming safety of the entire system related to this product Note that there may be hot or charged sections even after operation is stopped When inspecting or servicing the device turn off the energy source (air supply or water supply) and turn off power to the facility Discharge any compressed air from the system and pay enough attention to possible water leakage and leakage of electricity

When starting or restarting a machine or device that incorporates pneumatic components make sure that the system safety such as pop-out prevention measures is secured

Observe warnings and cautions on the pages below to prevent accidents

Observe corporate standards and regulations etc related to the safety of device design and control etcISO 4414 JIS B 8370 (pneumatic system rules)JFPS 2008 (principles for pneumatic cylinder selection and use)High Pressure Gas Maintenance Law Occupational Safety and Sanitation Laws other safety rules body standards and regulations etc

1 CKD cannot be held liable for any business interruption loss of profit personal injury delay cost or any other ancillary or indirect loss cost or damage resulting from the use of or faults in the use of CKD products

2 CKD cannot be held responsible for the following damage (1) Damage resulting from failure of CKD parts due to fire from reasons not attributable to CKD or by intentional

or negligence of a third party or customer (2) When a CKD product is assembled into customer equipment damage that could have been avoided if

customer equipment were provided with functions and structure etc generally accepted in the industry (3) Damage resulting from use exceeding the scope of specifications provided in CKD catalogs or instruction

manuals etc or from actions not following precautions for installation adjustment or maintenance etc (4) Damage resulting from production modifications not approved by CKD or from faults due to combination with

other software or other connected devices

Disclaimer

Allowable load mass1000

100

100 01 02 03 04 06

Load

mas

s(g

)

05Max speed v (ms)

LCM-8

LCM-6

LCM-45

Intro 4

Pneumatic components

Design amp Selection

Always read this section before starting useRefer to Pneumatic cylinders (CB-029SA) general details on cylinders and cylinder switch

Safety precautions

Use the cylinder with the tolerable absorption or less shown below If dynamic energy exceeds this value consider using a separate shock absorber

1 Common

CAUTION

Installation amp Adjustment

1 Common Piping

When changing a piping port position apply adhesive to M3 plug (hexagon socket head set screw)(Low intensity adhesive such as LOCTITE 222 221 THREE BOND1344 recommended)Tighten the plug to where the bolt does not protrude from the port or contact the base of the port hole Applicable piping joints are limited so refer to the below table

Bore size Φ45 Φ6 Φ8

Allowable energy absorption J 159times10-3 283times10-3 502times10-3

Refer to the LCM Selection Guide on pages 47 and 48 when selecting the cylinder When using the cylinder where it could be subject to water or oil exposure where it could corrode or where high levels of dust are present the cylinder could be damaged or malfunction Protect the product with a cover Stainless steel is used for the body and slide table but rust could form depending on the environment Regularly apply an anticorrosion agent The switch could malfunction if used in an environment including magnetic fields Magnetic sources around the switch could also cause malfunction When attaching a magnetic workpiece to the slide table check that the workpiece does not extend toward the switch from the end of the table Exposing this product to a powerful magnet could magnetize the product and cause the switch to malfunction

Bore size Recommended joints

All bore sizes

PG-S2-M3PG-S2-M3-SPG-L2-M3FTS4-M3FTL4-M3

Recommended joints

The slide table and end plate are supported by balls When fixing the jig with bolts support the slide table and end plate before tightening If held and tightened excessive moment on the guide could decrease guide section accuracy

Avoid denting or scratches that could obstruct the parallelism of the cylinder installation face or slide table face Maintain parallelism of the installation mate at 002 mm or less If parallelism is poor guide section accuracy could decrease rolling resistance could increase and product life could be adversely affected

Use a loose-fitting stepped pin (option) for positioning A press-fit dimension pin could damage the guide due to the load in press-fitting and result in faults The pin hole is a through hole so if a pin other than a stepped pin is used the pin could interfere and result in faults

Note FTL4-M3 cannot be used for the φ45 clean room specification dust port

D E

F

A

B

LCMSeries

Intro 5

Installation amp Adjustment

Cylinder installation

Jig installation

Model no Applicable bolts

Max tightening torqueNm

Dmm

LCM--45 M2times04 032 35LCM--6 M25times045 065 5LCM--8 M25times045 065 55

Model no Applicable bolts

Max tightening torqueNm

Emm

LCM--45 M25times045 065 35LCM--6 M3times05 114 5LCM--8 M3times05 114 55

Model no Applicable bolts

Max tightening torqueNm

Max screw depthF mm

LCM--45 M2times04 032 25LCM--6 M25times045 065 25LCM--8 M3times05 114 3

Model no Applicable bolts

Max tightening torqueNm

Max screw depthA mm

Max screw depthB mm

LCM--45 M3times05 063 4 45LCM--6 M3times05 063 4 55LCM--8 M3times05 063 5 55

Note The work installation bolt must be shorter than the maximum screw depth If it is too long it could contact the body and break

This cylinder switch can be changed to one with a switch and the switch installation face can be changed The tightening torque of the bolt fixing the switch rail is given below The switch installation face port is not used so attach a plug before assembling the switch rail

Model no Applicable bolts

Max tightening torqueNm

LCM--45 M2times04 017LCM--6 M2times04 017LCM--8 M2times04 017

C

Note Do not use a washer etc The installation bolt could contact the guide and break

Model no Applicable bolts

Max tightening torqueNm

Cmm

LCM-A-45 M3times05 114 5LCM-A-6 M3times05 114 5LCM-A-8 M4times07 27 4

When installing a jig guide slide table or end plate observe the following values for bolt screw depth and tightening torque

Cylinder installation (side installation)

3mm or longer

Magneticsubstance

DB

A

C

3mm or longer

Magneticsubstance

DB

A

C

The cylinder may malfunction if a magnetic substance such as a steel plate is nearby Move the magnetic substance to at least 3 mm from the cylinder (Same clearance for all bore size)

The cylinder switch may malfunction if cylinders are installed adjacently Separate cylinders with maintaining these distances A B C and D = 3 mm or longer (Same clearance for all bore size)

A A A

LCMSeries

Intro 6

Care must be taken as the product can not be installed vertically if of the type with a buffer

2 Side installation type 3 With buffer

CAUTION

Interval larger than dimensions listed on the table below must be maintained if the side installation type is installed in parallel

During Use amp Maintenance

CAUTION

Apply CGL grease (Nippon Thompson) to the track rails tracks of the guide after six months of use or 3000000 operations whichever is sooner

Model no A mmLCM-A-45 LCM-A-6 14LCM-A-8 16

Installation amp Adjustment

JIS symbol

Linear slide cylinder double acting single rod type

LCM Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCMBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCMSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 42 46 42 46 - - - - 3 10Φ6 58 63 58 63 66 7 - - 4 10Φ8 83 88 83 88 104 110 104 110 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCMSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM J2

R R6 10 J2LCM F2H

4

LCMSeriesHow to order

Dowel pin

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

J 45 LCM

Pin number

5

LCMSeries

Internal structure and parts list

LCM-45bull LCM-68bull

LCM-45 to 8 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel Guard Acetar resin Bolt Stainless steel 3 Stop plate Stainless steel3 End plate Aluminum alloy 14 Machine screw Stainless steel4 O ring Nitrile rubber 15 Floating bush B Stainless steel5 Rod cover Acetar resin 16 Cushion rubber Urethane rubber (Φ6 Φ8)6 Rod packing seal Nitrile rubber 7 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 18 Switch rail Aluminum alloy8 Slide table Stainless steel 9 Plate Aluminum alloy9 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel

10 Piston packing seal Nitrile rubber Magnet Plastic O ring Nitrile rubber Dowel pin Steel

6

LCMSeriesInternal structure and parts list

Internal structure and parts list

LCM-45 to 8 with bufferbull

Parts listNo Parts name Material Remarks

End plate Aluminum alloy Floating bush A Stainless steel3 Floating bush B Stainless steel4 Spring holder Copper alloy5 Coil spring Stainless steel

115 16 2-M3 x 05L side piping port (Note 1)

3

10

94

652-M3 x 05 depth 45

18 3

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42 ()

16

4

Φ3

+00

3 0

dept

h 1

8 05

4 55

9

3

7 16 4-Φ21

4-42 2-M2 x 04 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05R side piping port (Note 1)

235 32

1

32

35

3

115 16

3 28

Φ3 +003 0 depth 254-M25 x 045 depth 35 7 16

Φ3 +003 0

depth 25

8 34

45 15

3

35

7 Φ4h

7 0 -0

012

25 18

Φ3-0

002

-00

14

95

65 8 34115

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 52 () 16

4

3

7 16 4-Φ214-42

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

21

2-M3 x 05 depth 6(If two switches installed) (If one switch installed)

95

7

LCMSeries

Dimensions

LCM-45bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

45

112

72-M3 x 05 depth 55

14 20 14

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A ()

B

4

Φ3

+00

3 0

dept

h 1

8 05

4 75

3

7 C 4-Φ26

4-5 2-M25 x 045 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

21

32

45 E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

14 95

95

115 9 H

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 I () B

4

14

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)

J 14

99

21

2-M3 x 05 depth 6

8

LCMSeriesDimensions

LCM-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dimensions

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 49 30 34 40 40 59 40

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

5

14

125

82-M3 x 05 depth 55

16 24 18

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A ()

B

4

Φ3

+00

3 0

dept

h 2

8

05

5 85

14

4

7 C 4-Φ26

4-5 2-M3 x 05 depth 3

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

34 5

E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

18 35

5

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

95

114 9 H09

Φ3

+00

3 0

dept

h 2

8Φ3 +003 0 depth 28

4-M3 x 05 depth 5I ()

B4

18

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

3

(Note 1) Plugs are assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

9

LCMSeries

Dimensions

LCM-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 54 26 26 35 26 39 45 45 64 4520 54 26 26 35 26 39 45 45 64 45

10

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extended)

LCM-P SeriesBore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-PBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion NoneLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range mm -5 to 0Repeat position accuracy mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCM-PSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 49 53 49 53 - - - - 3 10Φ6 68 73 68 73 77 83 - - 4 10Φ8 97 102 97 102 120 126 120 126 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 5: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

Specification tableLCMSeries

Intro

Standard Option Custom order Not available

Standard stroke length (mm)

Option

Switc

h

Page

With

buf

fer

With

mag

net

With

mag

net +

sw

itch

rail

Dow

el p

in a

ttach

ed

5 10 15 20 B M F J

9

7

39

Note Custom stroke length is not available

Intro 3

The safety cautions are ranked as DANGER WARNING and CAUTION in this section

DANGER When a dangerous situation may occur if handling is mistaken leading to fatal or serious injuries or when there is a high degree of emergency to a warning

WARNING When a dangerous situation may occur if handling is mistaken leading to fatal or serious injuries

CAUTION When a dangerous situation may occur if handling is mistaken leading to minor injuries or physical damage

Note that some items described as ldquoCAUTIONrdquo may lead to serious results depending on the situationIn any case important information that must be observed is explained

When designing and manufacturing a device using CKD products the manufacturer is obligated to check that device safety mechanical mechanism pneumatic control circuit or water control circuit and the system operated by electrical control that controls the devices is securedIt is important to select use handle and maintain the product appropriately to ensure that the CKD product is used safelyObserve warnings and precautions to ensure device safetyCheck that device safety is ensured and manufacture a safe device

Always read this section before starting use

Safety precautions

WARNING This product is designed and manufactured as a general industrial machine part It must be handled by an operator having sufficient knowledge and experience in handling Use this product in accordance of specificationsThis product must be used within its stated specifications It must not be modified or machinedThis product is intended for use as a general-purpose industrial device or part It is not intended for use outdoors or for use under the following conditions or environmentNote that this product can be used when CKD is consulted prior to use and the customer consents to CKD product specifications The customer must provide safety measures to avoid risks in the event of problems

Use for special applications requiring safety including nuclear energy railroad aviation ship vehicle medical equipment equipment or applications coming into contact with beverage or food amusement equipment emergency shutoff circuits press machine brake circuits or for safeguard

Use for applications where life or assets could be adversely affected and special safety measures are required

Do not handle pipe or remove devices before confirming safety Inspect and service the machine and devices after confirming safety of the entire system related to this product Note that there may be hot or charged sections even after operation is stopped When inspecting or servicing the device turn off the energy source (air supply or water supply) and turn off power to the facility Discharge any compressed air from the system and pay enough attention to possible water leakage and leakage of electricity

When starting or restarting a machine or device that incorporates pneumatic components make sure that the system safety such as pop-out prevention measures is secured

Observe warnings and cautions on the pages below to prevent accidents

Observe corporate standards and regulations etc related to the safety of device design and control etcISO 4414 JIS B 8370 (pneumatic system rules)JFPS 2008 (principles for pneumatic cylinder selection and use)High Pressure Gas Maintenance Law Occupational Safety and Sanitation Laws other safety rules body standards and regulations etc

1 CKD cannot be held liable for any business interruption loss of profit personal injury delay cost or any other ancillary or indirect loss cost or damage resulting from the use of or faults in the use of CKD products

2 CKD cannot be held responsible for the following damage (1) Damage resulting from failure of CKD parts due to fire from reasons not attributable to CKD or by intentional

or negligence of a third party or customer (2) When a CKD product is assembled into customer equipment damage that could have been avoided if

customer equipment were provided with functions and structure etc generally accepted in the industry (3) Damage resulting from use exceeding the scope of specifications provided in CKD catalogs or instruction

manuals etc or from actions not following precautions for installation adjustment or maintenance etc (4) Damage resulting from production modifications not approved by CKD or from faults due to combination with

other software or other connected devices

Disclaimer

Allowable load mass1000

100

100 01 02 03 04 06

Load

mas

s(g

)

05Max speed v (ms)

LCM-8

LCM-6

LCM-45

Intro 4

Pneumatic components

Design amp Selection

Always read this section before starting useRefer to Pneumatic cylinders (CB-029SA) general details on cylinders and cylinder switch

Safety precautions

Use the cylinder with the tolerable absorption or less shown below If dynamic energy exceeds this value consider using a separate shock absorber

1 Common

CAUTION

Installation amp Adjustment

1 Common Piping

When changing a piping port position apply adhesive to M3 plug (hexagon socket head set screw)(Low intensity adhesive such as LOCTITE 222 221 THREE BOND1344 recommended)Tighten the plug to where the bolt does not protrude from the port or contact the base of the port hole Applicable piping joints are limited so refer to the below table

Bore size Φ45 Φ6 Φ8

Allowable energy absorption J 159times10-3 283times10-3 502times10-3

Refer to the LCM Selection Guide on pages 47 and 48 when selecting the cylinder When using the cylinder where it could be subject to water or oil exposure where it could corrode or where high levels of dust are present the cylinder could be damaged or malfunction Protect the product with a cover Stainless steel is used for the body and slide table but rust could form depending on the environment Regularly apply an anticorrosion agent The switch could malfunction if used in an environment including magnetic fields Magnetic sources around the switch could also cause malfunction When attaching a magnetic workpiece to the slide table check that the workpiece does not extend toward the switch from the end of the table Exposing this product to a powerful magnet could magnetize the product and cause the switch to malfunction

Bore size Recommended joints

All bore sizes

PG-S2-M3PG-S2-M3-SPG-L2-M3FTS4-M3FTL4-M3

Recommended joints

The slide table and end plate are supported by balls When fixing the jig with bolts support the slide table and end plate before tightening If held and tightened excessive moment on the guide could decrease guide section accuracy

Avoid denting or scratches that could obstruct the parallelism of the cylinder installation face or slide table face Maintain parallelism of the installation mate at 002 mm or less If parallelism is poor guide section accuracy could decrease rolling resistance could increase and product life could be adversely affected

Use a loose-fitting stepped pin (option) for positioning A press-fit dimension pin could damage the guide due to the load in press-fitting and result in faults The pin hole is a through hole so if a pin other than a stepped pin is used the pin could interfere and result in faults

Note FTL4-M3 cannot be used for the φ45 clean room specification dust port

D E

F

A

B

LCMSeries

Intro 5

Installation amp Adjustment

Cylinder installation

Jig installation

Model no Applicable bolts

Max tightening torqueNm

Dmm

LCM--45 M2times04 032 35LCM--6 M25times045 065 5LCM--8 M25times045 065 55

Model no Applicable bolts

Max tightening torqueNm

Emm

LCM--45 M25times045 065 35LCM--6 M3times05 114 5LCM--8 M3times05 114 55

Model no Applicable bolts

Max tightening torqueNm

Max screw depthF mm

LCM--45 M2times04 032 25LCM--6 M25times045 065 25LCM--8 M3times05 114 3

Model no Applicable bolts

Max tightening torqueNm

Max screw depthA mm

Max screw depthB mm

LCM--45 M3times05 063 4 45LCM--6 M3times05 063 4 55LCM--8 M3times05 063 5 55

Note The work installation bolt must be shorter than the maximum screw depth If it is too long it could contact the body and break

This cylinder switch can be changed to one with a switch and the switch installation face can be changed The tightening torque of the bolt fixing the switch rail is given below The switch installation face port is not used so attach a plug before assembling the switch rail

Model no Applicable bolts

Max tightening torqueNm

LCM--45 M2times04 017LCM--6 M2times04 017LCM--8 M2times04 017

C

Note Do not use a washer etc The installation bolt could contact the guide and break

Model no Applicable bolts

Max tightening torqueNm

Cmm

LCM-A-45 M3times05 114 5LCM-A-6 M3times05 114 5LCM-A-8 M4times07 27 4

When installing a jig guide slide table or end plate observe the following values for bolt screw depth and tightening torque

Cylinder installation (side installation)

3mm or longer

Magneticsubstance

DB

A

C

3mm or longer

Magneticsubstance

DB

A

C

The cylinder may malfunction if a magnetic substance such as a steel plate is nearby Move the magnetic substance to at least 3 mm from the cylinder (Same clearance for all bore size)

The cylinder switch may malfunction if cylinders are installed adjacently Separate cylinders with maintaining these distances A B C and D = 3 mm or longer (Same clearance for all bore size)

A A A

LCMSeries

Intro 6

Care must be taken as the product can not be installed vertically if of the type with a buffer

2 Side installation type 3 With buffer

CAUTION

Interval larger than dimensions listed on the table below must be maintained if the side installation type is installed in parallel

During Use amp Maintenance

CAUTION

Apply CGL grease (Nippon Thompson) to the track rails tracks of the guide after six months of use or 3000000 operations whichever is sooner

Model no A mmLCM-A-45 LCM-A-6 14LCM-A-8 16

Installation amp Adjustment

JIS symbol

Linear slide cylinder double acting single rod type

LCM Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCMBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCMSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 42 46 42 46 - - - - 3 10Φ6 58 63 58 63 66 7 - - 4 10Φ8 83 88 83 88 104 110 104 110 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCMSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM J2

R R6 10 J2LCM F2H

4

LCMSeriesHow to order

Dowel pin

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

J 45 LCM

Pin number

5

LCMSeries

Internal structure and parts list

LCM-45bull LCM-68bull

LCM-45 to 8 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel Guard Acetar resin Bolt Stainless steel 3 Stop plate Stainless steel3 End plate Aluminum alloy 14 Machine screw Stainless steel4 O ring Nitrile rubber 15 Floating bush B Stainless steel5 Rod cover Acetar resin 16 Cushion rubber Urethane rubber (Φ6 Φ8)6 Rod packing seal Nitrile rubber 7 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 18 Switch rail Aluminum alloy8 Slide table Stainless steel 9 Plate Aluminum alloy9 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel

10 Piston packing seal Nitrile rubber Magnet Plastic O ring Nitrile rubber Dowel pin Steel

6

LCMSeriesInternal structure and parts list

Internal structure and parts list

LCM-45 to 8 with bufferbull

Parts listNo Parts name Material Remarks

End plate Aluminum alloy Floating bush A Stainless steel3 Floating bush B Stainless steel4 Spring holder Copper alloy5 Coil spring Stainless steel

115 16 2-M3 x 05L side piping port (Note 1)

3

10

94

652-M3 x 05 depth 45

18 3

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42 ()

16

4

Φ3

+00

3 0

dept

h 1

8 05

4 55

9

3

7 16 4-Φ21

4-42 2-M2 x 04 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05R side piping port (Note 1)

235 32

1

32

35

3

115 16

3 28

Φ3 +003 0 depth 254-M25 x 045 depth 35 7 16

Φ3 +003 0

depth 25

8 34

45 15

3

35

7 Φ4h

7 0 -0

012

25 18

Φ3-0

002

-00

14

95

65 8 34115

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 52 () 16

4

3

7 16 4-Φ214-42

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

21

2-M3 x 05 depth 6(If two switches installed) (If one switch installed)

95

7

LCMSeries

Dimensions

LCM-45bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

45

112

72-M3 x 05 depth 55

14 20 14

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A ()

B

4

Φ3

+00

3 0

dept

h 1

8 05

4 75

3

7 C 4-Φ26

4-5 2-M25 x 045 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

21

32

45 E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

14 95

95

115 9 H

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 I () B

4

14

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)

J 14

99

21

2-M3 x 05 depth 6

8

LCMSeriesDimensions

LCM-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dimensions

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 49 30 34 40 40 59 40

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

5

14

125

82-M3 x 05 depth 55

16 24 18

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A ()

B

4

Φ3

+00

3 0

dept

h 2

8

05

5 85

14

4

7 C 4-Φ26

4-5 2-M3 x 05 depth 3

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

34 5

E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

18 35

5

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

95

114 9 H09

Φ3

+00

3 0

dept

h 2

8Φ3 +003 0 depth 28

4-M3 x 05 depth 5I ()

B4

18

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

3

(Note 1) Plugs are assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

9

LCMSeries

Dimensions

LCM-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 54 26 26 35 26 39 45 45 64 4520 54 26 26 35 26 39 45 45 64 45

10

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extended)

LCM-P SeriesBore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-PBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion NoneLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range mm -5 to 0Repeat position accuracy mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCM-PSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 49 53 49 53 - - - - 3 10Φ6 68 73 68 73 77 83 - - 4 10Φ8 97 102 97 102 120 126 120 126 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 6: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

Intro 3

The safety cautions are ranked as DANGER WARNING and CAUTION in this section

DANGER When a dangerous situation may occur if handling is mistaken leading to fatal or serious injuries or when there is a high degree of emergency to a warning

WARNING When a dangerous situation may occur if handling is mistaken leading to fatal or serious injuries

CAUTION When a dangerous situation may occur if handling is mistaken leading to minor injuries or physical damage

Note that some items described as ldquoCAUTIONrdquo may lead to serious results depending on the situationIn any case important information that must be observed is explained

When designing and manufacturing a device using CKD products the manufacturer is obligated to check that device safety mechanical mechanism pneumatic control circuit or water control circuit and the system operated by electrical control that controls the devices is securedIt is important to select use handle and maintain the product appropriately to ensure that the CKD product is used safelyObserve warnings and precautions to ensure device safetyCheck that device safety is ensured and manufacture a safe device

Always read this section before starting use

Safety precautions

WARNING This product is designed and manufactured as a general industrial machine part It must be handled by an operator having sufficient knowledge and experience in handling Use this product in accordance of specificationsThis product must be used within its stated specifications It must not be modified or machinedThis product is intended for use as a general-purpose industrial device or part It is not intended for use outdoors or for use under the following conditions or environmentNote that this product can be used when CKD is consulted prior to use and the customer consents to CKD product specifications The customer must provide safety measures to avoid risks in the event of problems

Use for special applications requiring safety including nuclear energy railroad aviation ship vehicle medical equipment equipment or applications coming into contact with beverage or food amusement equipment emergency shutoff circuits press machine brake circuits or for safeguard

Use for applications where life or assets could be adversely affected and special safety measures are required

Do not handle pipe or remove devices before confirming safety Inspect and service the machine and devices after confirming safety of the entire system related to this product Note that there may be hot or charged sections even after operation is stopped When inspecting or servicing the device turn off the energy source (air supply or water supply) and turn off power to the facility Discharge any compressed air from the system and pay enough attention to possible water leakage and leakage of electricity

When starting or restarting a machine or device that incorporates pneumatic components make sure that the system safety such as pop-out prevention measures is secured

Observe warnings and cautions on the pages below to prevent accidents

Observe corporate standards and regulations etc related to the safety of device design and control etcISO 4414 JIS B 8370 (pneumatic system rules)JFPS 2008 (principles for pneumatic cylinder selection and use)High Pressure Gas Maintenance Law Occupational Safety and Sanitation Laws other safety rules body standards and regulations etc

1 CKD cannot be held liable for any business interruption loss of profit personal injury delay cost or any other ancillary or indirect loss cost or damage resulting from the use of or faults in the use of CKD products

2 CKD cannot be held responsible for the following damage (1) Damage resulting from failure of CKD parts due to fire from reasons not attributable to CKD or by intentional

or negligence of a third party or customer (2) When a CKD product is assembled into customer equipment damage that could have been avoided if

customer equipment were provided with functions and structure etc generally accepted in the industry (3) Damage resulting from use exceeding the scope of specifications provided in CKD catalogs or instruction

manuals etc or from actions not following precautions for installation adjustment or maintenance etc (4) Damage resulting from production modifications not approved by CKD or from faults due to combination with

other software or other connected devices

Disclaimer

Allowable load mass1000

100

100 01 02 03 04 06

Load

mas

s(g

)

05Max speed v (ms)

LCM-8

LCM-6

LCM-45

Intro 4

Pneumatic components

Design amp Selection

Always read this section before starting useRefer to Pneumatic cylinders (CB-029SA) general details on cylinders and cylinder switch

Safety precautions

Use the cylinder with the tolerable absorption or less shown below If dynamic energy exceeds this value consider using a separate shock absorber

1 Common

CAUTION

Installation amp Adjustment

1 Common Piping

When changing a piping port position apply adhesive to M3 plug (hexagon socket head set screw)(Low intensity adhesive such as LOCTITE 222 221 THREE BOND1344 recommended)Tighten the plug to where the bolt does not protrude from the port or contact the base of the port hole Applicable piping joints are limited so refer to the below table

Bore size Φ45 Φ6 Φ8

Allowable energy absorption J 159times10-3 283times10-3 502times10-3

Refer to the LCM Selection Guide on pages 47 and 48 when selecting the cylinder When using the cylinder where it could be subject to water or oil exposure where it could corrode or where high levels of dust are present the cylinder could be damaged or malfunction Protect the product with a cover Stainless steel is used for the body and slide table but rust could form depending on the environment Regularly apply an anticorrosion agent The switch could malfunction if used in an environment including magnetic fields Magnetic sources around the switch could also cause malfunction When attaching a magnetic workpiece to the slide table check that the workpiece does not extend toward the switch from the end of the table Exposing this product to a powerful magnet could magnetize the product and cause the switch to malfunction

Bore size Recommended joints

All bore sizes

PG-S2-M3PG-S2-M3-SPG-L2-M3FTS4-M3FTL4-M3

Recommended joints

The slide table and end plate are supported by balls When fixing the jig with bolts support the slide table and end plate before tightening If held and tightened excessive moment on the guide could decrease guide section accuracy

Avoid denting or scratches that could obstruct the parallelism of the cylinder installation face or slide table face Maintain parallelism of the installation mate at 002 mm or less If parallelism is poor guide section accuracy could decrease rolling resistance could increase and product life could be adversely affected

Use a loose-fitting stepped pin (option) for positioning A press-fit dimension pin could damage the guide due to the load in press-fitting and result in faults The pin hole is a through hole so if a pin other than a stepped pin is used the pin could interfere and result in faults

Note FTL4-M3 cannot be used for the φ45 clean room specification dust port

D E

F

A

B

LCMSeries

Intro 5

Installation amp Adjustment

Cylinder installation

Jig installation

Model no Applicable bolts

Max tightening torqueNm

Dmm

LCM--45 M2times04 032 35LCM--6 M25times045 065 5LCM--8 M25times045 065 55

Model no Applicable bolts

Max tightening torqueNm

Emm

LCM--45 M25times045 065 35LCM--6 M3times05 114 5LCM--8 M3times05 114 55

Model no Applicable bolts

Max tightening torqueNm

Max screw depthF mm

LCM--45 M2times04 032 25LCM--6 M25times045 065 25LCM--8 M3times05 114 3

Model no Applicable bolts

Max tightening torqueNm

Max screw depthA mm

Max screw depthB mm

LCM--45 M3times05 063 4 45LCM--6 M3times05 063 4 55LCM--8 M3times05 063 5 55

Note The work installation bolt must be shorter than the maximum screw depth If it is too long it could contact the body and break

This cylinder switch can be changed to one with a switch and the switch installation face can be changed The tightening torque of the bolt fixing the switch rail is given below The switch installation face port is not used so attach a plug before assembling the switch rail

Model no Applicable bolts

Max tightening torqueNm

LCM--45 M2times04 017LCM--6 M2times04 017LCM--8 M2times04 017

C

Note Do not use a washer etc The installation bolt could contact the guide and break

Model no Applicable bolts

Max tightening torqueNm

Cmm

LCM-A-45 M3times05 114 5LCM-A-6 M3times05 114 5LCM-A-8 M4times07 27 4

When installing a jig guide slide table or end plate observe the following values for bolt screw depth and tightening torque

Cylinder installation (side installation)

3mm or longer

Magneticsubstance

DB

A

C

3mm or longer

Magneticsubstance

DB

A

C

The cylinder may malfunction if a magnetic substance such as a steel plate is nearby Move the magnetic substance to at least 3 mm from the cylinder (Same clearance for all bore size)

The cylinder switch may malfunction if cylinders are installed adjacently Separate cylinders with maintaining these distances A B C and D = 3 mm or longer (Same clearance for all bore size)

A A A

LCMSeries

Intro 6

Care must be taken as the product can not be installed vertically if of the type with a buffer

2 Side installation type 3 With buffer

CAUTION

Interval larger than dimensions listed on the table below must be maintained if the side installation type is installed in parallel

During Use amp Maintenance

CAUTION

Apply CGL grease (Nippon Thompson) to the track rails tracks of the guide after six months of use or 3000000 operations whichever is sooner

Model no A mmLCM-A-45 LCM-A-6 14LCM-A-8 16

Installation amp Adjustment

JIS symbol

Linear slide cylinder double acting single rod type

LCM Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCMBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCMSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 42 46 42 46 - - - - 3 10Φ6 58 63 58 63 66 7 - - 4 10Φ8 83 88 83 88 104 110 104 110 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCMSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM J2

R R6 10 J2LCM F2H

4

LCMSeriesHow to order

Dowel pin

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

J 45 LCM

Pin number

5

LCMSeries

Internal structure and parts list

LCM-45bull LCM-68bull

LCM-45 to 8 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel Guard Acetar resin Bolt Stainless steel 3 Stop plate Stainless steel3 End plate Aluminum alloy 14 Machine screw Stainless steel4 O ring Nitrile rubber 15 Floating bush B Stainless steel5 Rod cover Acetar resin 16 Cushion rubber Urethane rubber (Φ6 Φ8)6 Rod packing seal Nitrile rubber 7 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 18 Switch rail Aluminum alloy8 Slide table Stainless steel 9 Plate Aluminum alloy9 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel

10 Piston packing seal Nitrile rubber Magnet Plastic O ring Nitrile rubber Dowel pin Steel

6

LCMSeriesInternal structure and parts list

Internal structure and parts list

LCM-45 to 8 with bufferbull

Parts listNo Parts name Material Remarks

End plate Aluminum alloy Floating bush A Stainless steel3 Floating bush B Stainless steel4 Spring holder Copper alloy5 Coil spring Stainless steel

115 16 2-M3 x 05L side piping port (Note 1)

3

10

94

652-M3 x 05 depth 45

18 3

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42 ()

16

4

Φ3

+00

3 0

dept

h 1

8 05

4 55

9

3

7 16 4-Φ21

4-42 2-M2 x 04 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05R side piping port (Note 1)

235 32

1

32

35

3

115 16

3 28

Φ3 +003 0 depth 254-M25 x 045 depth 35 7 16

Φ3 +003 0

depth 25

8 34

45 15

3

35

7 Φ4h

7 0 -0

012

25 18

Φ3-0

002

-00

14

95

65 8 34115

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 52 () 16

4

3

7 16 4-Φ214-42

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

21

2-M3 x 05 depth 6(If two switches installed) (If one switch installed)

95

7

LCMSeries

Dimensions

LCM-45bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

45

112

72-M3 x 05 depth 55

14 20 14

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A ()

B

4

Φ3

+00

3 0

dept

h 1

8 05

4 75

3

7 C 4-Φ26

4-5 2-M25 x 045 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

21

32

45 E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

14 95

95

115 9 H

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 I () B

4

14

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)

J 14

99

21

2-M3 x 05 depth 6

8

LCMSeriesDimensions

LCM-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dimensions

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 49 30 34 40 40 59 40

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

5

14

125

82-M3 x 05 depth 55

16 24 18

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A ()

B

4

Φ3

+00

3 0

dept

h 2

8

05

5 85

14

4

7 C 4-Φ26

4-5 2-M3 x 05 depth 3

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

34 5

E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

18 35

5

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

95

114 9 H09

Φ3

+00

3 0

dept

h 2

8Φ3 +003 0 depth 28

4-M3 x 05 depth 5I ()

B4

18

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

3

(Note 1) Plugs are assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

9

LCMSeries

Dimensions

LCM-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 54 26 26 35 26 39 45 45 64 4520 54 26 26 35 26 39 45 45 64 45

10

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extended)

LCM-P SeriesBore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-PBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion NoneLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range mm -5 to 0Repeat position accuracy mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCM-PSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 49 53 49 53 - - - - 3 10Φ6 68 73 68 73 77 83 - - 4 10Φ8 97 102 97 102 120 126 120 126 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 7: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

Allowable load mass1000

100

100 01 02 03 04 06

Load

mas

s(g

)

05Max speed v (ms)

LCM-8

LCM-6

LCM-45

Intro 4

Pneumatic components

Design amp Selection

Always read this section before starting useRefer to Pneumatic cylinders (CB-029SA) general details on cylinders and cylinder switch

Safety precautions

Use the cylinder with the tolerable absorption or less shown below If dynamic energy exceeds this value consider using a separate shock absorber

1 Common

CAUTION

Installation amp Adjustment

1 Common Piping

When changing a piping port position apply adhesive to M3 plug (hexagon socket head set screw)(Low intensity adhesive such as LOCTITE 222 221 THREE BOND1344 recommended)Tighten the plug to where the bolt does not protrude from the port or contact the base of the port hole Applicable piping joints are limited so refer to the below table

Bore size Φ45 Φ6 Φ8

Allowable energy absorption J 159times10-3 283times10-3 502times10-3

Refer to the LCM Selection Guide on pages 47 and 48 when selecting the cylinder When using the cylinder where it could be subject to water or oil exposure where it could corrode or where high levels of dust are present the cylinder could be damaged or malfunction Protect the product with a cover Stainless steel is used for the body and slide table but rust could form depending on the environment Regularly apply an anticorrosion agent The switch could malfunction if used in an environment including magnetic fields Magnetic sources around the switch could also cause malfunction When attaching a magnetic workpiece to the slide table check that the workpiece does not extend toward the switch from the end of the table Exposing this product to a powerful magnet could magnetize the product and cause the switch to malfunction

Bore size Recommended joints

All bore sizes

PG-S2-M3PG-S2-M3-SPG-L2-M3FTS4-M3FTL4-M3

Recommended joints

The slide table and end plate are supported by balls When fixing the jig with bolts support the slide table and end plate before tightening If held and tightened excessive moment on the guide could decrease guide section accuracy

Avoid denting or scratches that could obstruct the parallelism of the cylinder installation face or slide table face Maintain parallelism of the installation mate at 002 mm or less If parallelism is poor guide section accuracy could decrease rolling resistance could increase and product life could be adversely affected

Use a loose-fitting stepped pin (option) for positioning A press-fit dimension pin could damage the guide due to the load in press-fitting and result in faults The pin hole is a through hole so if a pin other than a stepped pin is used the pin could interfere and result in faults

Note FTL4-M3 cannot be used for the φ45 clean room specification dust port

D E

F

A

B

LCMSeries

Intro 5

Installation amp Adjustment

Cylinder installation

Jig installation

Model no Applicable bolts

Max tightening torqueNm

Dmm

LCM--45 M2times04 032 35LCM--6 M25times045 065 5LCM--8 M25times045 065 55

Model no Applicable bolts

Max tightening torqueNm

Emm

LCM--45 M25times045 065 35LCM--6 M3times05 114 5LCM--8 M3times05 114 55

Model no Applicable bolts

Max tightening torqueNm

Max screw depthF mm

LCM--45 M2times04 032 25LCM--6 M25times045 065 25LCM--8 M3times05 114 3

Model no Applicable bolts

Max tightening torqueNm

Max screw depthA mm

Max screw depthB mm

LCM--45 M3times05 063 4 45LCM--6 M3times05 063 4 55LCM--8 M3times05 063 5 55

Note The work installation bolt must be shorter than the maximum screw depth If it is too long it could contact the body and break

This cylinder switch can be changed to one with a switch and the switch installation face can be changed The tightening torque of the bolt fixing the switch rail is given below The switch installation face port is not used so attach a plug before assembling the switch rail

Model no Applicable bolts

Max tightening torqueNm

LCM--45 M2times04 017LCM--6 M2times04 017LCM--8 M2times04 017

C

Note Do not use a washer etc The installation bolt could contact the guide and break

Model no Applicable bolts

Max tightening torqueNm

Cmm

LCM-A-45 M3times05 114 5LCM-A-6 M3times05 114 5LCM-A-8 M4times07 27 4

When installing a jig guide slide table or end plate observe the following values for bolt screw depth and tightening torque

Cylinder installation (side installation)

3mm or longer

Magneticsubstance

DB

A

C

3mm or longer

Magneticsubstance

DB

A

C

The cylinder may malfunction if a magnetic substance such as a steel plate is nearby Move the magnetic substance to at least 3 mm from the cylinder (Same clearance for all bore size)

The cylinder switch may malfunction if cylinders are installed adjacently Separate cylinders with maintaining these distances A B C and D = 3 mm or longer (Same clearance for all bore size)

A A A

LCMSeries

Intro 6

Care must be taken as the product can not be installed vertically if of the type with a buffer

2 Side installation type 3 With buffer

CAUTION

Interval larger than dimensions listed on the table below must be maintained if the side installation type is installed in parallel

During Use amp Maintenance

CAUTION

Apply CGL grease (Nippon Thompson) to the track rails tracks of the guide after six months of use or 3000000 operations whichever is sooner

Model no A mmLCM-A-45 LCM-A-6 14LCM-A-8 16

Installation amp Adjustment

JIS symbol

Linear slide cylinder double acting single rod type

LCM Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCMBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCMSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 42 46 42 46 - - - - 3 10Φ6 58 63 58 63 66 7 - - 4 10Φ8 83 88 83 88 104 110 104 110 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCMSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM J2

R R6 10 J2LCM F2H

4

LCMSeriesHow to order

Dowel pin

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

J 45 LCM

Pin number

5

LCMSeries

Internal structure and parts list

LCM-45bull LCM-68bull

LCM-45 to 8 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel Guard Acetar resin Bolt Stainless steel 3 Stop plate Stainless steel3 End plate Aluminum alloy 14 Machine screw Stainless steel4 O ring Nitrile rubber 15 Floating bush B Stainless steel5 Rod cover Acetar resin 16 Cushion rubber Urethane rubber (Φ6 Φ8)6 Rod packing seal Nitrile rubber 7 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 18 Switch rail Aluminum alloy8 Slide table Stainless steel 9 Plate Aluminum alloy9 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel

10 Piston packing seal Nitrile rubber Magnet Plastic O ring Nitrile rubber Dowel pin Steel

6

LCMSeriesInternal structure and parts list

Internal structure and parts list

LCM-45 to 8 with bufferbull

Parts listNo Parts name Material Remarks

End plate Aluminum alloy Floating bush A Stainless steel3 Floating bush B Stainless steel4 Spring holder Copper alloy5 Coil spring Stainless steel

115 16 2-M3 x 05L side piping port (Note 1)

3

10

94

652-M3 x 05 depth 45

18 3

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42 ()

16

4

Φ3

+00

3 0

dept

h 1

8 05

4 55

9

3

7 16 4-Φ21

4-42 2-M2 x 04 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05R side piping port (Note 1)

235 32

1

32

35

3

115 16

3 28

Φ3 +003 0 depth 254-M25 x 045 depth 35 7 16

Φ3 +003 0

depth 25

8 34

45 15

3

35

7 Φ4h

7 0 -0

012

25 18

Φ3-0

002

-00

14

95

65 8 34115

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 52 () 16

4

3

7 16 4-Φ214-42

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

21

2-M3 x 05 depth 6(If two switches installed) (If one switch installed)

95

7

LCMSeries

Dimensions

LCM-45bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

45

112

72-M3 x 05 depth 55

14 20 14

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A ()

B

4

Φ3

+00

3 0

dept

h 1

8 05

4 75

3

7 C 4-Φ26

4-5 2-M25 x 045 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

21

32

45 E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

14 95

95

115 9 H

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 I () B

4

14

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)

J 14

99

21

2-M3 x 05 depth 6

8

LCMSeriesDimensions

LCM-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dimensions

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 49 30 34 40 40 59 40

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

5

14

125

82-M3 x 05 depth 55

16 24 18

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A ()

B

4

Φ3

+00

3 0

dept

h 2

8

05

5 85

14

4

7 C 4-Φ26

4-5 2-M3 x 05 depth 3

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

34 5

E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

18 35

5

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

95

114 9 H09

Φ3

+00

3 0

dept

h 2

8Φ3 +003 0 depth 28

4-M3 x 05 depth 5I ()

B4

18

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

3

(Note 1) Plugs are assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

9

LCMSeries

Dimensions

LCM-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 54 26 26 35 26 39 45 45 64 4520 54 26 26 35 26 39 45 45 64 45

10

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extended)

LCM-P SeriesBore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-PBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion NoneLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range mm -5 to 0Repeat position accuracy mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCM-PSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 49 53 49 53 - - - - 3 10Φ6 68 73 68 73 77 83 - - 4 10Φ8 97 102 97 102 120 126 120 126 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 8: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

D E

F

A

B

LCMSeries

Intro 5

Installation amp Adjustment

Cylinder installation

Jig installation

Model no Applicable bolts

Max tightening torqueNm

Dmm

LCM--45 M2times04 032 35LCM--6 M25times045 065 5LCM--8 M25times045 065 55

Model no Applicable bolts

Max tightening torqueNm

Emm

LCM--45 M25times045 065 35LCM--6 M3times05 114 5LCM--8 M3times05 114 55

Model no Applicable bolts

Max tightening torqueNm

Max screw depthF mm

LCM--45 M2times04 032 25LCM--6 M25times045 065 25LCM--8 M3times05 114 3

Model no Applicable bolts

Max tightening torqueNm

Max screw depthA mm

Max screw depthB mm

LCM--45 M3times05 063 4 45LCM--6 M3times05 063 4 55LCM--8 M3times05 063 5 55

Note The work installation bolt must be shorter than the maximum screw depth If it is too long it could contact the body and break

This cylinder switch can be changed to one with a switch and the switch installation face can be changed The tightening torque of the bolt fixing the switch rail is given below The switch installation face port is not used so attach a plug before assembling the switch rail

Model no Applicable bolts

Max tightening torqueNm

LCM--45 M2times04 017LCM--6 M2times04 017LCM--8 M2times04 017

C

Note Do not use a washer etc The installation bolt could contact the guide and break

Model no Applicable bolts

Max tightening torqueNm

Cmm

LCM-A-45 M3times05 114 5LCM-A-6 M3times05 114 5LCM-A-8 M4times07 27 4

When installing a jig guide slide table or end plate observe the following values for bolt screw depth and tightening torque

Cylinder installation (side installation)

3mm or longer

Magneticsubstance

DB

A

C

3mm or longer

Magneticsubstance

DB

A

C

The cylinder may malfunction if a magnetic substance such as a steel plate is nearby Move the magnetic substance to at least 3 mm from the cylinder (Same clearance for all bore size)

The cylinder switch may malfunction if cylinders are installed adjacently Separate cylinders with maintaining these distances A B C and D = 3 mm or longer (Same clearance for all bore size)

A A A

LCMSeries

Intro 6

Care must be taken as the product can not be installed vertically if of the type with a buffer

2 Side installation type 3 With buffer

CAUTION

Interval larger than dimensions listed on the table below must be maintained if the side installation type is installed in parallel

During Use amp Maintenance

CAUTION

Apply CGL grease (Nippon Thompson) to the track rails tracks of the guide after six months of use or 3000000 operations whichever is sooner

Model no A mmLCM-A-45 LCM-A-6 14LCM-A-8 16

Installation amp Adjustment

JIS symbol

Linear slide cylinder double acting single rod type

LCM Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCMBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCMSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 42 46 42 46 - - - - 3 10Φ6 58 63 58 63 66 7 - - 4 10Φ8 83 88 83 88 104 110 104 110 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCMSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM J2

R R6 10 J2LCM F2H

4

LCMSeriesHow to order

Dowel pin

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

J 45 LCM

Pin number

5

LCMSeries

Internal structure and parts list

LCM-45bull LCM-68bull

LCM-45 to 8 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel Guard Acetar resin Bolt Stainless steel 3 Stop plate Stainless steel3 End plate Aluminum alloy 14 Machine screw Stainless steel4 O ring Nitrile rubber 15 Floating bush B Stainless steel5 Rod cover Acetar resin 16 Cushion rubber Urethane rubber (Φ6 Φ8)6 Rod packing seal Nitrile rubber 7 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 18 Switch rail Aluminum alloy8 Slide table Stainless steel 9 Plate Aluminum alloy9 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel

10 Piston packing seal Nitrile rubber Magnet Plastic O ring Nitrile rubber Dowel pin Steel

6

LCMSeriesInternal structure and parts list

Internal structure and parts list

LCM-45 to 8 with bufferbull

Parts listNo Parts name Material Remarks

End plate Aluminum alloy Floating bush A Stainless steel3 Floating bush B Stainless steel4 Spring holder Copper alloy5 Coil spring Stainless steel

115 16 2-M3 x 05L side piping port (Note 1)

3

10

94

652-M3 x 05 depth 45

18 3

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42 ()

16

4

Φ3

+00

3 0

dept

h 1

8 05

4 55

9

3

7 16 4-Φ21

4-42 2-M2 x 04 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05R side piping port (Note 1)

235 32

1

32

35

3

115 16

3 28

Φ3 +003 0 depth 254-M25 x 045 depth 35 7 16

Φ3 +003 0

depth 25

8 34

45 15

3

35

7 Φ4h

7 0 -0

012

25 18

Φ3-0

002

-00

14

95

65 8 34115

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 52 () 16

4

3

7 16 4-Φ214-42

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

21

2-M3 x 05 depth 6(If two switches installed) (If one switch installed)

95

7

LCMSeries

Dimensions

LCM-45bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

45

112

72-M3 x 05 depth 55

14 20 14

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A ()

B

4

Φ3

+00

3 0

dept

h 1

8 05

4 75

3

7 C 4-Φ26

4-5 2-M25 x 045 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

21

32

45 E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

14 95

95

115 9 H

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 I () B

4

14

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)

J 14

99

21

2-M3 x 05 depth 6

8

LCMSeriesDimensions

LCM-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dimensions

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 49 30 34 40 40 59 40

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

5

14

125

82-M3 x 05 depth 55

16 24 18

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A ()

B

4

Φ3

+00

3 0

dept

h 2

8

05

5 85

14

4

7 C 4-Φ26

4-5 2-M3 x 05 depth 3

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

34 5

E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

18 35

5

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

95

114 9 H09

Φ3

+00

3 0

dept

h 2

8Φ3 +003 0 depth 28

4-M3 x 05 depth 5I ()

B4

18

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

3

(Note 1) Plugs are assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

9

LCMSeries

Dimensions

LCM-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 54 26 26 35 26 39 45 45 64 4520 54 26 26 35 26 39 45 45 64 45

10

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extended)

LCM-P SeriesBore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-PBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion NoneLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range mm -5 to 0Repeat position accuracy mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCM-PSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 49 53 49 53 - - - - 3 10Φ6 68 73 68 73 77 83 - - 4 10Φ8 97 102 97 102 120 126 120 126 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 9: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

A A A

LCMSeries

Intro 6

Care must be taken as the product can not be installed vertically if of the type with a buffer

2 Side installation type 3 With buffer

CAUTION

Interval larger than dimensions listed on the table below must be maintained if the side installation type is installed in parallel

During Use amp Maintenance

CAUTION

Apply CGL grease (Nippon Thompson) to the track rails tracks of the guide after six months of use or 3000000 operations whichever is sooner

Model no A mmLCM-A-45 LCM-A-6 14LCM-A-8 16

Installation amp Adjustment

JIS symbol

Linear slide cylinder double acting single rod type

LCM Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCMBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCMSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 42 46 42 46 - - - - 3 10Φ6 58 63 58 63 66 7 - - 4 10Φ8 83 88 83 88 104 110 104 110 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCMSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM J2

R R6 10 J2LCM F2H

4

LCMSeriesHow to order

Dowel pin

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

J 45 LCM

Pin number

5

LCMSeries

Internal structure and parts list

LCM-45bull LCM-68bull

LCM-45 to 8 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel Guard Acetar resin Bolt Stainless steel 3 Stop plate Stainless steel3 End plate Aluminum alloy 14 Machine screw Stainless steel4 O ring Nitrile rubber 15 Floating bush B Stainless steel5 Rod cover Acetar resin 16 Cushion rubber Urethane rubber (Φ6 Φ8)6 Rod packing seal Nitrile rubber 7 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 18 Switch rail Aluminum alloy8 Slide table Stainless steel 9 Plate Aluminum alloy9 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel

10 Piston packing seal Nitrile rubber Magnet Plastic O ring Nitrile rubber Dowel pin Steel

6

LCMSeriesInternal structure and parts list

Internal structure and parts list

LCM-45 to 8 with bufferbull

Parts listNo Parts name Material Remarks

End plate Aluminum alloy Floating bush A Stainless steel3 Floating bush B Stainless steel4 Spring holder Copper alloy5 Coil spring Stainless steel

115 16 2-M3 x 05L side piping port (Note 1)

3

10

94

652-M3 x 05 depth 45

18 3

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42 ()

16

4

Φ3

+00

3 0

dept

h 1

8 05

4 55

9

3

7 16 4-Φ21

4-42 2-M2 x 04 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05R side piping port (Note 1)

235 32

1

32

35

3

115 16

3 28

Φ3 +003 0 depth 254-M25 x 045 depth 35 7 16

Φ3 +003 0

depth 25

8 34

45 15

3

35

7 Φ4h

7 0 -0

012

25 18

Φ3-0

002

-00

14

95

65 8 34115

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 52 () 16

4

3

7 16 4-Φ214-42

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

21

2-M3 x 05 depth 6(If two switches installed) (If one switch installed)

95

7

LCMSeries

Dimensions

LCM-45bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

45

112

72-M3 x 05 depth 55

14 20 14

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A ()

B

4

Φ3

+00

3 0

dept

h 1

8 05

4 75

3

7 C 4-Φ26

4-5 2-M25 x 045 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

21

32

45 E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

14 95

95

115 9 H

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 I () B

4

14

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)

J 14

99

21

2-M3 x 05 depth 6

8

LCMSeriesDimensions

LCM-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dimensions

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 49 30 34 40 40 59 40

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

5

14

125

82-M3 x 05 depth 55

16 24 18

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A ()

B

4

Φ3

+00

3 0

dept

h 2

8

05

5 85

14

4

7 C 4-Φ26

4-5 2-M3 x 05 depth 3

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

34 5

E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

18 35

5

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

95

114 9 H09

Φ3

+00

3 0

dept

h 2

8Φ3 +003 0 depth 28

4-M3 x 05 depth 5I ()

B4

18

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

3

(Note 1) Plugs are assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

9

LCMSeries

Dimensions

LCM-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 54 26 26 35 26 39 45 45 64 4520 54 26 26 35 26 39 45 45 64 45

10

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extended)

LCM-P SeriesBore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-PBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion NoneLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range mm -5 to 0Repeat position accuracy mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCM-PSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 49 53 49 53 - - - - 3 10Φ6 68 73 68 73 77 83 - - 4 10Φ8 97 102 97 102 120 126 120 126 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 10: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

JIS symbol

Linear slide cylinder double acting single rod type

LCM Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCMBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCMSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 42 46 42 46 - - - - 3 10Φ6 58 63 58 63 66 7 - - 4 10Φ8 83 88 83 88 104 110 104 110 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCMSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM J2

R R6 10 J2LCM F2H

4

LCMSeriesHow to order

Dowel pin

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

J 45 LCM

Pin number

5

LCMSeries

Internal structure and parts list

LCM-45bull LCM-68bull

LCM-45 to 8 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel Guard Acetar resin Bolt Stainless steel 3 Stop plate Stainless steel3 End plate Aluminum alloy 14 Machine screw Stainless steel4 O ring Nitrile rubber 15 Floating bush B Stainless steel5 Rod cover Acetar resin 16 Cushion rubber Urethane rubber (Φ6 Φ8)6 Rod packing seal Nitrile rubber 7 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 18 Switch rail Aluminum alloy8 Slide table Stainless steel 9 Plate Aluminum alloy9 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel

10 Piston packing seal Nitrile rubber Magnet Plastic O ring Nitrile rubber Dowel pin Steel

6

LCMSeriesInternal structure and parts list

Internal structure and parts list

LCM-45 to 8 with bufferbull

Parts listNo Parts name Material Remarks

End plate Aluminum alloy Floating bush A Stainless steel3 Floating bush B Stainless steel4 Spring holder Copper alloy5 Coil spring Stainless steel

115 16 2-M3 x 05L side piping port (Note 1)

3

10

94

652-M3 x 05 depth 45

18 3

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42 ()

16

4

Φ3

+00

3 0

dept

h 1

8 05

4 55

9

3

7 16 4-Φ21

4-42 2-M2 x 04 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05R side piping port (Note 1)

235 32

1

32

35

3

115 16

3 28

Φ3 +003 0 depth 254-M25 x 045 depth 35 7 16

Φ3 +003 0

depth 25

8 34

45 15

3

35

7 Φ4h

7 0 -0

012

25 18

Φ3-0

002

-00

14

95

65 8 34115

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 52 () 16

4

3

7 16 4-Φ214-42

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

21

2-M3 x 05 depth 6(If two switches installed) (If one switch installed)

95

7

LCMSeries

Dimensions

LCM-45bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

45

112

72-M3 x 05 depth 55

14 20 14

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A ()

B

4

Φ3

+00

3 0

dept

h 1

8 05

4 75

3

7 C 4-Φ26

4-5 2-M25 x 045 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

21

32

45 E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

14 95

95

115 9 H

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 I () B

4

14

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)

J 14

99

21

2-M3 x 05 depth 6

8

LCMSeriesDimensions

LCM-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dimensions

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 49 30 34 40 40 59 40

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

5

14

125

82-M3 x 05 depth 55

16 24 18

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A ()

B

4

Φ3

+00

3 0

dept

h 2

8

05

5 85

14

4

7 C 4-Φ26

4-5 2-M3 x 05 depth 3

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

34 5

E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

18 35

5

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

95

114 9 H09

Φ3

+00

3 0

dept

h 2

8Φ3 +003 0 depth 28

4-M3 x 05 depth 5I ()

B4

18

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

3

(Note 1) Plugs are assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

9

LCMSeries

Dimensions

LCM-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 54 26 26 35 26 39 45 45 64 4520 54 26 26 35 26 39 45 45 64 45

10

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extended)

LCM-P SeriesBore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-PBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion NoneLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range mm -5 to 0Repeat position accuracy mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCM-PSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 49 53 49 53 - - - - 3 10Φ6 68 73 68 73 77 83 - - 4 10Φ8 97 102 97 102 120 126 120 126 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 11: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

LCMSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 42 46 42 46 - - - - 3 10Φ6 58 63 58 63 66 7 - - 4 10Φ8 83 88 83 88 104 110 104 110 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCMSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM J2

R R6 10 J2LCM F2H

4

LCMSeriesHow to order

Dowel pin

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

J 45 LCM

Pin number

5

LCMSeries

Internal structure and parts list

LCM-45bull LCM-68bull

LCM-45 to 8 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel Guard Acetar resin Bolt Stainless steel 3 Stop plate Stainless steel3 End plate Aluminum alloy 14 Machine screw Stainless steel4 O ring Nitrile rubber 15 Floating bush B Stainless steel5 Rod cover Acetar resin 16 Cushion rubber Urethane rubber (Φ6 Φ8)6 Rod packing seal Nitrile rubber 7 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 18 Switch rail Aluminum alloy8 Slide table Stainless steel 9 Plate Aluminum alloy9 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel

10 Piston packing seal Nitrile rubber Magnet Plastic O ring Nitrile rubber Dowel pin Steel

6

LCMSeriesInternal structure and parts list

Internal structure and parts list

LCM-45 to 8 with bufferbull

Parts listNo Parts name Material Remarks

End plate Aluminum alloy Floating bush A Stainless steel3 Floating bush B Stainless steel4 Spring holder Copper alloy5 Coil spring Stainless steel

115 16 2-M3 x 05L side piping port (Note 1)

3

10

94

652-M3 x 05 depth 45

18 3

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42 ()

16

4

Φ3

+00

3 0

dept

h 1

8 05

4 55

9

3

7 16 4-Φ21

4-42 2-M2 x 04 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05R side piping port (Note 1)

235 32

1

32

35

3

115 16

3 28

Φ3 +003 0 depth 254-M25 x 045 depth 35 7 16

Φ3 +003 0

depth 25

8 34

45 15

3

35

7 Φ4h

7 0 -0

012

25 18

Φ3-0

002

-00

14

95

65 8 34115

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 52 () 16

4

3

7 16 4-Φ214-42

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

21

2-M3 x 05 depth 6(If two switches installed) (If one switch installed)

95

7

LCMSeries

Dimensions

LCM-45bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

45

112

72-M3 x 05 depth 55

14 20 14

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A ()

B

4

Φ3

+00

3 0

dept

h 1

8 05

4 75

3

7 C 4-Φ26

4-5 2-M25 x 045 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

21

32

45 E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

14 95

95

115 9 H

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 I () B

4

14

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)

J 14

99

21

2-M3 x 05 depth 6

8

LCMSeriesDimensions

LCM-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dimensions

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 49 30 34 40 40 59 40

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

5

14

125

82-M3 x 05 depth 55

16 24 18

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A ()

B

4

Φ3

+00

3 0

dept

h 2

8

05

5 85

14

4

7 C 4-Φ26

4-5 2-M3 x 05 depth 3

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

34 5

E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

18 35

5

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

95

114 9 H09

Φ3

+00

3 0

dept

h 2

8Φ3 +003 0 depth 28

4-M3 x 05 depth 5I ()

B4

18

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

3

(Note 1) Plugs are assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

9

LCMSeries

Dimensions

LCM-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 54 26 26 35 26 39 45 45 64 4520 54 26 26 35 26 39 45 45 64 45

10

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extended)

LCM-P SeriesBore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-PBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion NoneLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range mm -5 to 0Repeat position accuracy mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCM-PSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 49 53 49 53 - - - - 3 10Φ6 68 73 68 73 77 83 - - 4 10Φ8 97 102 97 102 120 126 120 126 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 12: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

3

LCMSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM J2

R R6 10 J2LCM F2H

4

LCMSeriesHow to order

Dowel pin

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

J 45 LCM

Pin number

5

LCMSeries

Internal structure and parts list

LCM-45bull LCM-68bull

LCM-45 to 8 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel Guard Acetar resin Bolt Stainless steel 3 Stop plate Stainless steel3 End plate Aluminum alloy 14 Machine screw Stainless steel4 O ring Nitrile rubber 15 Floating bush B Stainless steel5 Rod cover Acetar resin 16 Cushion rubber Urethane rubber (Φ6 Φ8)6 Rod packing seal Nitrile rubber 7 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 18 Switch rail Aluminum alloy8 Slide table Stainless steel 9 Plate Aluminum alloy9 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel

10 Piston packing seal Nitrile rubber Magnet Plastic O ring Nitrile rubber Dowel pin Steel

6

LCMSeriesInternal structure and parts list

Internal structure and parts list

LCM-45 to 8 with bufferbull

Parts listNo Parts name Material Remarks

End plate Aluminum alloy Floating bush A Stainless steel3 Floating bush B Stainless steel4 Spring holder Copper alloy5 Coil spring Stainless steel

115 16 2-M3 x 05L side piping port (Note 1)

3

10

94

652-M3 x 05 depth 45

18 3

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42 ()

16

4

Φ3

+00

3 0

dept

h 1

8 05

4 55

9

3

7 16 4-Φ21

4-42 2-M2 x 04 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05R side piping port (Note 1)

235 32

1

32

35

3

115 16

3 28

Φ3 +003 0 depth 254-M25 x 045 depth 35 7 16

Φ3 +003 0

depth 25

8 34

45 15

3

35

7 Φ4h

7 0 -0

012

25 18

Φ3-0

002

-00

14

95

65 8 34115

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 52 () 16

4

3

7 16 4-Φ214-42

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

21

2-M3 x 05 depth 6(If two switches installed) (If one switch installed)

95

7

LCMSeries

Dimensions

LCM-45bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

45

112

72-M3 x 05 depth 55

14 20 14

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A ()

B

4

Φ3

+00

3 0

dept

h 1

8 05

4 75

3

7 C 4-Φ26

4-5 2-M25 x 045 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

21

32

45 E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

14 95

95

115 9 H

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 I () B

4

14

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)

J 14

99

21

2-M3 x 05 depth 6

8

LCMSeriesDimensions

LCM-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dimensions

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 49 30 34 40 40 59 40

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

5

14

125

82-M3 x 05 depth 55

16 24 18

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A ()

B

4

Φ3

+00

3 0

dept

h 2

8

05

5 85

14

4

7 C 4-Φ26

4-5 2-M3 x 05 depth 3

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

34 5

E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

18 35

5

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

95

114 9 H09

Φ3

+00

3 0

dept

h 2

8Φ3 +003 0 depth 28

4-M3 x 05 depth 5I ()

B4

18

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

3

(Note 1) Plugs are assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

9

LCMSeries

Dimensions

LCM-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 54 26 26 35 26 39 45 45 64 4520 54 26 26 35 26 39 45 45 64 45

10

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extended)

LCM-P SeriesBore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-PBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion NoneLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range mm -5 to 0Repeat position accuracy mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCM-PSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 49 53 49 53 - - - - 3 10Φ6 68 73 68 73 77 83 - - 4 10Φ8 97 102 97 102 120 126 120 126 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 13: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

4

LCMSeriesHow to order

Dowel pin

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

J 45 LCM

Pin number

5

LCMSeries

Internal structure and parts list

LCM-45bull LCM-68bull

LCM-45 to 8 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel Guard Acetar resin Bolt Stainless steel 3 Stop plate Stainless steel3 End plate Aluminum alloy 14 Machine screw Stainless steel4 O ring Nitrile rubber 15 Floating bush B Stainless steel5 Rod cover Acetar resin 16 Cushion rubber Urethane rubber (Φ6 Φ8)6 Rod packing seal Nitrile rubber 7 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 18 Switch rail Aluminum alloy8 Slide table Stainless steel 9 Plate Aluminum alloy9 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel

10 Piston packing seal Nitrile rubber Magnet Plastic O ring Nitrile rubber Dowel pin Steel

6

LCMSeriesInternal structure and parts list

Internal structure and parts list

LCM-45 to 8 with bufferbull

Parts listNo Parts name Material Remarks

End plate Aluminum alloy Floating bush A Stainless steel3 Floating bush B Stainless steel4 Spring holder Copper alloy5 Coil spring Stainless steel

115 16 2-M3 x 05L side piping port (Note 1)

3

10

94

652-M3 x 05 depth 45

18 3

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42 ()

16

4

Φ3

+00

3 0

dept

h 1

8 05

4 55

9

3

7 16 4-Φ21

4-42 2-M2 x 04 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05R side piping port (Note 1)

235 32

1

32

35

3

115 16

3 28

Φ3 +003 0 depth 254-M25 x 045 depth 35 7 16

Φ3 +003 0

depth 25

8 34

45 15

3

35

7 Φ4h

7 0 -0

012

25 18

Φ3-0

002

-00

14

95

65 8 34115

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 52 () 16

4

3

7 16 4-Φ214-42

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

21

2-M3 x 05 depth 6(If two switches installed) (If one switch installed)

95

7

LCMSeries

Dimensions

LCM-45bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

45

112

72-M3 x 05 depth 55

14 20 14

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A ()

B

4

Φ3

+00

3 0

dept

h 1

8 05

4 75

3

7 C 4-Φ26

4-5 2-M25 x 045 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

21

32

45 E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

14 95

95

115 9 H

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 I () B

4

14

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)

J 14

99

21

2-M3 x 05 depth 6

8

LCMSeriesDimensions

LCM-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dimensions

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 49 30 34 40 40 59 40

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

5

14

125

82-M3 x 05 depth 55

16 24 18

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A ()

B

4

Φ3

+00

3 0

dept

h 2

8

05

5 85

14

4

7 C 4-Φ26

4-5 2-M3 x 05 depth 3

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

34 5

E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

18 35

5

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

95

114 9 H09

Φ3

+00

3 0

dept

h 2

8Φ3 +003 0 depth 28

4-M3 x 05 depth 5I ()

B4

18

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

3

(Note 1) Plugs are assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

9

LCMSeries

Dimensions

LCM-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 54 26 26 35 26 39 45 45 64 4520 54 26 26 35 26 39 45 45 64 45

10

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extended)

LCM-P SeriesBore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-PBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion NoneLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range mm -5 to 0Repeat position accuracy mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCM-PSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 49 53 49 53 - - - - 3 10Φ6 68 73 68 73 77 83 - - 4 10Φ8 97 102 97 102 120 126 120 126 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 14: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

5

LCMSeries

Internal structure and parts list

LCM-45bull LCM-68bull

LCM-45 to 8 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel Guard Acetar resin Bolt Stainless steel 3 Stop plate Stainless steel3 End plate Aluminum alloy 14 Machine screw Stainless steel4 O ring Nitrile rubber 15 Floating bush B Stainless steel5 Rod cover Acetar resin 16 Cushion rubber Urethane rubber (Φ6 Φ8)6 Rod packing seal Nitrile rubber 7 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 18 Switch rail Aluminum alloy8 Slide table Stainless steel 9 Plate Aluminum alloy9 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel

10 Piston packing seal Nitrile rubber Magnet Plastic O ring Nitrile rubber Dowel pin Steel

6

LCMSeriesInternal structure and parts list

Internal structure and parts list

LCM-45 to 8 with bufferbull

Parts listNo Parts name Material Remarks

End plate Aluminum alloy Floating bush A Stainless steel3 Floating bush B Stainless steel4 Spring holder Copper alloy5 Coil spring Stainless steel

115 16 2-M3 x 05L side piping port (Note 1)

3

10

94

652-M3 x 05 depth 45

18 3

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42 ()

16

4

Φ3

+00

3 0

dept

h 1

8 05

4 55

9

3

7 16 4-Φ21

4-42 2-M2 x 04 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05R side piping port (Note 1)

235 32

1

32

35

3

115 16

3 28

Φ3 +003 0 depth 254-M25 x 045 depth 35 7 16

Φ3 +003 0

depth 25

8 34

45 15

3

35

7 Φ4h

7 0 -0

012

25 18

Φ3-0

002

-00

14

95

65 8 34115

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 52 () 16

4

3

7 16 4-Φ214-42

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

21

2-M3 x 05 depth 6(If two switches installed) (If one switch installed)

95

7

LCMSeries

Dimensions

LCM-45bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

45

112

72-M3 x 05 depth 55

14 20 14

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A ()

B

4

Φ3

+00

3 0

dept

h 1

8 05

4 75

3

7 C 4-Φ26

4-5 2-M25 x 045 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

21

32

45 E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

14 95

95

115 9 H

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 I () B

4

14

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)

J 14

99

21

2-M3 x 05 depth 6

8

LCMSeriesDimensions

LCM-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dimensions

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 49 30 34 40 40 59 40

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

5

14

125

82-M3 x 05 depth 55

16 24 18

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A ()

B

4

Φ3

+00

3 0

dept

h 2

8

05

5 85

14

4

7 C 4-Φ26

4-5 2-M3 x 05 depth 3

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

34 5

E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

18 35

5

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

95

114 9 H09

Φ3

+00

3 0

dept

h 2

8Φ3 +003 0 depth 28

4-M3 x 05 depth 5I ()

B4

18

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

3

(Note 1) Plugs are assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

9

LCMSeries

Dimensions

LCM-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 54 26 26 35 26 39 45 45 64 4520 54 26 26 35 26 39 45 45 64 45

10

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extended)

LCM-P SeriesBore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-PBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion NoneLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range mm -5 to 0Repeat position accuracy mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCM-PSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 49 53 49 53 - - - - 3 10Φ6 68 73 68 73 77 83 - - 4 10Φ8 97 102 97 102 120 126 120 126 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 15: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

6

LCMSeriesInternal structure and parts list

Internal structure and parts list

LCM-45 to 8 with bufferbull

Parts listNo Parts name Material Remarks

End plate Aluminum alloy Floating bush A Stainless steel3 Floating bush B Stainless steel4 Spring holder Copper alloy5 Coil spring Stainless steel

115 16 2-M3 x 05L side piping port (Note 1)

3

10

94

652-M3 x 05 depth 45

18 3

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42 ()

16

4

Φ3

+00

3 0

dept

h 1

8 05

4 55

9

3

7 16 4-Φ21

4-42 2-M2 x 04 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05R side piping port (Note 1)

235 32

1

32

35

3

115 16

3 28

Φ3 +003 0 depth 254-M25 x 045 depth 35 7 16

Φ3 +003 0

depth 25

8 34

45 15

3

35

7 Φ4h

7 0 -0

012

25 18

Φ3-0

002

-00

14

95

65 8 34115

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 52 () 16

4

3

7 16 4-Φ214-42

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

21

2-M3 x 05 depth 6(If two switches installed) (If one switch installed)

95

7

LCMSeries

Dimensions

LCM-45bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

45

112

72-M3 x 05 depth 55

14 20 14

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A ()

B

4

Φ3

+00

3 0

dept

h 1

8 05

4 75

3

7 C 4-Φ26

4-5 2-M25 x 045 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

21

32

45 E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

14 95

95

115 9 H

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 I () B

4

14

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)

J 14

99

21

2-M3 x 05 depth 6

8

LCMSeriesDimensions

LCM-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dimensions

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 49 30 34 40 40 59 40

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

5

14

125

82-M3 x 05 depth 55

16 24 18

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A ()

B

4

Φ3

+00

3 0

dept

h 2

8

05

5 85

14

4

7 C 4-Φ26

4-5 2-M3 x 05 depth 3

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

34 5

E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

18 35

5

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

95

114 9 H09

Φ3

+00

3 0

dept

h 2

8Φ3 +003 0 depth 28

4-M3 x 05 depth 5I ()

B4

18

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

3

(Note 1) Plugs are assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

9

LCMSeries

Dimensions

LCM-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 54 26 26 35 26 39 45 45 64 4520 54 26 26 35 26 39 45 45 64 45

10

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extended)

LCM-P SeriesBore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-PBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion NoneLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range mm -5 to 0Repeat position accuracy mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCM-PSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 49 53 49 53 - - - - 3 10Φ6 68 73 68 73 77 83 - - 4 10Φ8 97 102 97 102 120 126 120 126 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 16: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

115 16 2-M3 x 05L side piping port (Note 1)

3

10

94

652-M3 x 05 depth 45

18 3

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42 ()

16

4

Φ3

+00

3 0

dept

h 1

8 05

4 55

9

3

7 16 4-Φ21

4-42 2-M2 x 04 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05R side piping port (Note 1)

235 32

1

32

35

3

115 16

3 28

Φ3 +003 0 depth 254-M25 x 045 depth 35 7 16

Φ3 +003 0

depth 25

8 34

45 15

3

35

7 Φ4h

7 0 -0

012

25 18

Φ3-0

002

-00

14

95

65 8 34115

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 52 () 16

4

3

7 16 4-Φ214-42

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

21

2-M3 x 05 depth 6(If two switches installed) (If one switch installed)

95

7

LCMSeries

Dimensions

LCM-45bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

45

112

72-M3 x 05 depth 55

14 20 14

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A ()

B

4

Φ3

+00

3 0

dept

h 1

8 05

4 75

3

7 C 4-Φ26

4-5 2-M25 x 045 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

21

32

45 E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

14 95

95

115 9 H

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 I () B

4

14

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)

J 14

99

21

2-M3 x 05 depth 6

8

LCMSeriesDimensions

LCM-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dimensions

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 49 30 34 40 40 59 40

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

5

14

125

82-M3 x 05 depth 55

16 24 18

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A ()

B

4

Φ3

+00

3 0

dept

h 2

8

05

5 85

14

4

7 C 4-Φ26

4-5 2-M3 x 05 depth 3

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

34 5

E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

18 35

5

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

95

114 9 H09

Φ3

+00

3 0

dept

h 2

8Φ3 +003 0 depth 28

4-M3 x 05 depth 5I ()

B4

18

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

3

(Note 1) Plugs are assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

9

LCMSeries

Dimensions

LCM-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 54 26 26 35 26 39 45 45 64 4520 54 26 26 35 26 39 45 45 64 45

10

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extended)

LCM-P SeriesBore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-PBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion NoneLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range mm -5 to 0Repeat position accuracy mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCM-PSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 49 53 49 53 - - - - 3 10Φ6 68 73 68 73 77 83 - - 4 10Φ8 97 102 97 102 120 126 120 126 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 17: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

E 2-M3 x 05 L side piping port (Note 1)

45

112

72-M3 x 05 depth 55

14 20 14

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A ()

B

4

Φ3

+00

3 0

dept

h 1

8 05

4 75

3

7 C 4-Φ26

4-5 2-M25 x 045 depth 25

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

21

32

45 E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

14 95

95

115 9 H

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

Φ3

+00

3 0

dept

h 1

8Φ3 +003 0 depth 18

4-M3 x 05 depth 4 I () B

4

14

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)

J 14

99

21

2-M3 x 05 depth 6

8

LCMSeriesDimensions

LCM-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dimensions

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 49 30 34 40 40 59 40

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

E 2-M3 x 05 L side piping port (Note 1)

5

14

125

82-M3 x 05 depth 55

16 24 18

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A ()

B

4

Φ3

+00

3 0

dept

h 2

8

05

5 85

14

4

7 C 4-Φ26

4-5 2-M3 x 05 depth 3

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

34 5

E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

18 35

5

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

95

114 9 H09

Φ3

+00

3 0

dept

h 2

8Φ3 +003 0 depth 28

4-M3 x 05 depth 5I ()

B4

18

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

3

(Note 1) Plugs are assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

9

LCMSeries

Dimensions

LCM-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 54 26 26 35 26 39 45 45 64 4520 54 26 26 35 26 39 45 45 64 45

10

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extended)

LCM-P SeriesBore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-PBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion NoneLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range mm -5 to 0Repeat position accuracy mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCM-PSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 49 53 49 53 - - - - 3 10Φ6 68 73 68 73 77 83 - - 4 10Φ8 97 102 97 102 120 126 120 126 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 18: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

E 2-M3 x 05 L side piping port (Note 1)

5

14

125

82-M3 x 05 depth 55

16 24 18

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A ()

B

4

Φ3

+00

3 0

dept

h 2

8

05

5 85

14

4

7 C 4-Φ26

4-5 2-M3 x 05 depth 3

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

D 14

34 5

E

3 F

Φ3 +003 0 depth 254-M3 x 05 depth 5 7 C

3 +003 0

depth 25

9 G

55 15

4

18 35

5

25 18

Φ4h

7 0 -0

012

Φ3-0

002

-00

14

95

114 9 H09

Φ3

+00

3 0

dept

h 2

8Φ3 +003 0 depth 28

4-M3 x 05 depth 5I ()

B4

18

7 C 4-Φ26

4-5

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

3

(Note 1) Plugs are assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

9

LCMSeries

Dimensions

LCM-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Dowel pin (-J)bullStroke length A B C D E F G H I J5 44 16 16 25 16 9 35 35 54 35

10 44 16 16 25 16 9 35 35 54 3515 54 26 26 35 26 39 45 45 64 4520 54 26 26 35 26 39 45 45 64 45

10

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extended)

LCM-P SeriesBore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-PBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion NoneLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range mm -5 to 0Repeat position accuracy mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCM-PSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 49 53 49 53 - - - - 3 10Φ6 68 73 68 73 77 83 - - 4 10Φ8 97 102 97 102 120 126 120 126 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 19: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

10

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extended)

LCM-P SeriesBore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-PBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion NoneLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range mm -5 to 0Repeat position accuracy mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCM-PSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 49 53 49 53 - - - - 3 10Φ6 68 73 68 73 77 83 - - 4 10Φ8 97 102 97 102 120 126 120 126 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 20: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extended)

LCM-P SeriesBore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-PBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion NoneLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range mm -5 to 0Repeat position accuracy mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

LCM-PSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 49 53 49 53 - - - - 3 10Φ6 68 73 68 73 77 83 - - 4 10Φ8 97 102 97 102 120 126 120 126 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 21: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

LCM-PSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 49 53 49 53 - - - - 3 10Φ6 68 73 68 73 77 83 - - 4 10Φ8 97 102 97 102 120 126 120 126 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 22: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

3

LCM-PSeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-P-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extended)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-P J2

R6 10LCM-P R J2F2H

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 23: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

14

LCM-PSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 24: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

15

LCM-PSeries

Internal structure and parts list

LCM-P-45bull LCM-P-68bull

LCM-P-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 Adjustable stopper Steel Nickel plating Bolt Stainless steel

15 Hexagon nutΦ45 Stainless steel

3 End plate Aluminum alloy Φ6 Φ8 Steel Nickel plating4 Rod cover Acetar resin 16 O ring Nitrile rubber5 Rod packing seal Nitrile rubber 7 Floating bush B Stainless steel6 Cylinder body Stainless steel 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Slide table Stainless steel 9 O ring Nitrile rubber8 Piston Stainless steel 20 Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy Switch rail Aluminum alloy Stop plate Stainless steel 3 Plate Aluminum alloy Machine screw Stainless steel 24 Hexagon socket head cap screw Stainless steel3 Stopper A Steel Nickel plating 25 Magnet Plastic

26 Dowel pin Steel

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 25: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16

4

65

16 + stroke length

Stroke length

10

6594

18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

7

55

16

2-M2 x 04 depth 25 (for magnet installation both sides)235 3

21

458

Width across flats 5Width across flats 4

(58

)

35

4-M3 x 05 depth 4Φ3 +003

0 depth 1852

16

465

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

21

818 (5

8) 35

4-42

Note Refer to Page 46 for switch installation position dimensions

115

95

8 3465

95

(If two switches installed) (If one switch installed)

4-Φ21

Width across flats 5

Width across flats 4

16

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 26: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

4-M3 x 05 depth 4Φ3 +003

0 depth 18 A

B4

7

9 + stroke length

Stroke length

14 20 14

2-M3 x 05 depth 55

7 C

4-Φ26

Φ3 +003 0 depth 18

9

75

18

2-M2 x 04 depth 25 (for magnet installation both sides)D 14

21

559

Width across flats 6

Width across flats 55

(69

)4

5

4-5

115

95

9 H4-M3 x 05 depth 4

Φ3 +003 0 depth 18 I

B4

7

9 + stroke length

Stroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

21

99

Width across flats 6

Width across flats 55(6

9)

45

4-5

Note Refer to Page 46 for switch installation position dimensions

7

112

7

LCM-PSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 27: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

A B

47

9 + stroke lengthStroke length

14

16 24 18

2-M3 x 05 depth 5-57 C

4-Φ26

Φ3 +003 0 depth 28

10585

2-M2 x 04 depth 25(for magnet installation both sides)

D 14

3

Width across flats 8Width across flats 55

(92

)5

5

8

1254-5

09

95

9 H1144-M3 x 05 depth 5Φ3 +003

0 depth 28 I B

4

79 + stroke length

Stroke length

18

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 28

2-M2 x 04 depth 25(for magnet installation both sides) J 14

3

9

9

Width across flats 8 Width across

flats 55(9

2)

55

4-5

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

559

Note Refer to Page 46 for switch installation position dimensions

18

LCM-PSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-P-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 28: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

9

JIS symbol

Linear slide cylinder double acting stroke adjustable type (extendedretracted)

LCM-R Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-RBore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 025 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500

CushionExtended NoneRetracted None

Lubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Adjustable stroke range

Extended mm -5 to 0Retracted mm -7 to 0

Repeatability mm plusmn002Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 29: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

20

LCM-RSeriesSpecifications

Switch specifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 52 56 52 56 - - - - 3 10Φ6 7 76 7 76 80 86 - - 4 10Φ8 100 105 100 105 3 9 3 9 5 10

Unit g

Theoretical thrust tableBore size (mm) Working pressure MPa

02 03 04 05 06 07Φ45 26 38 51 64 77 90Φ6 42 64 85 106 127 148Φ8 86 130 173 216 259 302

Unit N

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 30: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

LCM-RSeries

How to orderWithout switchbullWith switchbull

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-R-6-10-R-F2H-R-J2Model Linear slide cylinder double acting stroke adjustable type (extendedretracted)A Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-R J2

R6 10LCM-R R J2F2H

E Switch quantity

D Switch model no

A Bore size

B Stroke length

C Piping direction

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

E Switch quantityR One on rod endH One on head endD Two

F OptionB With bufferM Note With magnetF1 Note 1 2 Magnet + switch rail (one switch groove)F2 Note Magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

F Option

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 31: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

LCM-RSeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 32: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

3

LCM-RSeries

Internal structure and parts list

LCM-R-45bull LCM-R-68bull

LCM-R-45 to 8 with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel16 Hexagon nut

Φ45 Stainless steel Bolt Stainless steel Φ6 Φ8 Steel Nickel plating3 End plate Aluminum alloy 7 O ring Nitrile rubber4 Rod cover Acetar resin 18 Floating bush B Stainless steel5 Rod packing seal Nitrile rubber 9 Cushion rubber Urethane rubber (Φ6 Φ8)6 Cylinder body Stainless steel 20 O ring Nitrile rubber7 Slide table Stainless steel Machine screw Stainless steel8 Piston Stainless steel Stopper A Steel Nickel plating9 Piston packing seal Nitrile rubber 3 Hexagon socket head cap screw Stainless steel

10 Guard Aluminum alloy 24 Hexagon socket head cap screw Stainless steel Stopper B Steel Nickel plating 25 Switch rail Aluminum alloy Machine screw Stainless steel 26 Plate Aluminum alloy3 Hexagon nut Stainless steel 7 Hexagon socket head cap screw Stainless steel14 Stopper bolt Stainless steel 28 Magnet Plastic 15 Adjustable stopper Steel Nickel plating 9 Dowel pin Steel

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 33: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

4

16 + stroke length

Stroke length

10 18 3

2-M3 x 05 depth 457 16

4-42 Φ3 +003 0 depth 18

(3)

16

2-M2 x 04 depth 25 (for magnet installation both sides)235

Width across flats 15Width across flats 55

(58

)

35

6594

4-M3 x 05 depth 4Φ3 +003

0 depth 18

42

16 65

3 Width across flats 15 55

15 84

21

3

458

M3 x 05 length 15

Width across flats 5Width across flats 4

98

65 8 34

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18 4

65

16 + stroke length

Stroke length

3

2-M3 x 05 depth 67 16 4-Φ21

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)335 3

818

Width across flats 4

Width across flats 55

(58

)3

5

4-42

1652

3

Width across flats 5

21

98

95

115

(If two switches installed) (If one switch installed)

4-Φ21

24

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-45bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 34: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

4

9 + stroke length

Stroke length

14 20 142-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 18

(15)

14

18

D

Width across flats 15Width across flats 55

(69

)

45

7112

4-M3 x 05 depth 4Φ3 +003

0 depth 18

AB

7

3 Width across flats 15 75

15 84

21 14

559

M3 x 05 length 15Width across flats 6

Width across flats 55

118

4-5

115 9 H

95

4-M3 x 05 depth 4Φ3 +003

0 depth 18

47

9 + stroke lengthStroke length

14

2-M3 x 05 depth 67 C 4-Φ26

Φ3 +003 0 depth 18

2-M2 x 04 depth 25 (for magnet installation both sides)J 14

99

Width across flats 55

Width across flats 55(6

9)

45

4-5

BI

3

Width across flats 6

21

118

25

LCM-RSeries

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-6bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 49 30 40 59 40

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 35: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

4

9 + stroke length

Stroke length

14

16 24 182-M3 x 05 depth 55

7 C 4-Φ26Φ3 +003

0 depth 28

(162)

16

DWidth across flats 15Width across flats 55

(92

)

55

8125

AB 7

3 Width across flats 15 85

9

3

14

559

M3 x 05 length 15Width across flats 8Width across flats 55

3

4-5

2-M2 x 04 depth 25(for magnet installation both sides)

09 9 H

95

114 4-M3 x 05 depth 5Φ3 +003

0 depth 28

47

9 + stroke lengthStroke length

18

2-M3 x 05 depth 67 C 4-Φ26

3 +003 0 depth 18

2-M2 x 04 depth 25(for magnet installation both sides) J 14

99

Width across flats 55Width across flats 55

(92

)5

5

4-5

BI

3

Width across flats 8

3

3

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

26

LCM-RSeriesDimensions

Dimensions (Dimensions other than listed below are the same as double acting single rod type Refer to Page 7)

LCM-R-8bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

With buffer (-B)bull

Note Refer to Page 46 for switch installation position dimensions

Stroke length A B C D H I J5 44 16 16 25 35 54 35

10 44 16 16 25 35 54 3515 54 26 26 35 45 64 4520 54 26 26 35 45 64 45

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 36: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

7

JIS symbol

Linear slide cylinder double acting side installation type

LCM-A Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM-ABore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 500Cushion None Rubber cushionedLubrication Not required (when lubricating use turbine oil Class 1 ISOVG 32)Allowable energy absorption J Refer to table on Page 4 in the Introduction

With buffer specificationsDescriptions LCM----BBuffer stroke length mm 4 (Max)Buffer section spring load

Set N 03Operation N 07

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with switch (mm)

Φ45 5 105Φ6 5 10 15

Φ8 5 10 15 20Note 1 Other than standard stroke length is not available

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 37: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

28

LCM-ASeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With buffer

Weight per

switchΦ45 59 63 59 63 - - - - 3 10Φ6 78 83 78 83 88 94 - - 4 10Φ8 106 106 3 138 3 138 5 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 38: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

9

LCM-ASeries

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Table direction

With switchbullSymbol Descriptions

A Bore size (mm)45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Table directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionF OptionB With bufferM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-A-6-10-R-F2H-R-J2Model Linear slide cylinder double acting side installation typeA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)

R6 10LCM-A J2

R6 10LCM-A R J2F2H

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 39: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

30

LCM-ASeriesHow to order

How to order switchSwitch body + switch rail + magnetbull Only switch bodybull

D Switch model no

A Bore size

B Stroke length

E Switch quantity

Φ45bullOnly magnetbull

D Switch model no

Switch rail

Magnet

A Bore size

How to order discrete dowel pin

Φ6 Φ8bull

Switch rail

A Bore sizeB Stroke length

F2H R 6 10LCM F2HSW

M 6LCMF1F2LCM 45

6F2 10LCM

Only switch railbull

Dowel pin

J 45 LCM

Pin number

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 40: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

3

LCM-ASeries

Internal structure and parts list

LCM-A-45bull LCM-A-68bull

LCM-A-45 to 8-F with magnet and switch railbull Dowel pin (-J)bull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 14 End plate Aluminum alloy Bolt Stainless steel 15 O ring Nitrile rubber3 Slide table Stainless steel 16 Floating bush B Stainless steel4 Rod cover Acetar resin 7 Hexagon socket head cap screw Stainless steel5 Rod packing seal Nitrile rubber 18 O ring Nitrile rubber6 Machine screw Stainless steel 9 Hexagon socket head cap screw Stainless steel7 Cylinder body Stainless steel 20 Base Aluminum alloy8 Piston Note Stainless steel Hexagon socket head cap screw Stainless steel9 Piston packing seal Nitrile rubber Switch rail Aluminum alloy

10 O ring Nitrile rubber 3 Plate Aluminum alloy Head cover Aluminum alloy Alumite 24 Hexagon socket head cap screw Stainless steel Bolt Stainless steel 25 Magnet Plastic3 Cushion rubber Urethane rubber (Φ6 Φ8) 26 Dowel pin Steel

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 41: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

3

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 42: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

3 47

65

4

21

235 3

65

3

65

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-Φ34

2-M2 x 04 depth 25 (for magnet installation)

10

94

6508

7

18

1152-M3 x 05 depth 45 M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

5 83

3+0

03

0de

pth

18

2-M3 x 05 piping port 55

6

9

2-Φ3H 8 +0014 0 depth 33 47

9

45

8 34 5

21 64 8 34

365

3 47

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

42

1

335 3

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

52 16

4

18

53

5

83

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

Note Refer to Page 46 for switch installation position dimensions

95

114

(If two switches installed) (If one switch installed)

365

95

21

2-M3 x 05 depth 6

33

LCM-ASeries

Dimensions

LCM-A-45-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Dowel pin (-J)bull

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 43: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

45

8345

347

65

3

65

2353

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

9

55

6 83

5

115

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

42

16

4

18

53

3+0

03

0D

epth

18

2-Φ3H8 +0014 0 depth 3 347

92-Φ34

2-M3 x 05 depth 45

10

94

65 08

18

7

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

2164834

365

347

65 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21

3353

36

5

2-Φ34

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8 52

164

18

53

58

3

95

95

114

(If two switches installed)(If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

2-M2 x 04 depth 25(for magnet installation)

2-M3 x 05 depth 6

365

21

34

LCM-ASeriesDimensions

Dimensions

LCM-A-45-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 44: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

3 A

65

3

65

B 14

65

4

21

2-M3 x 05 with plug

2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

683

5

3

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +0014 0 depth 33 A

10

55

55F9

2-Φ34

2-M3 x 05 depth 55

14

112

708

14 20

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

21 114 9 G

385

95

Note Refer to Page 46 for switch installation position dimensions

A365 652-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

4

21 H 14

3

65

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 18

4-M3 x 05 depth 4

Φ3

+00

3 0

dept

h 1

8

ID

4

9

14

E

5

83

2-M3 x 05 depth 6

35

LCM-ASeries

Dimensions

LCM-A-6-R (piping direction right)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 45: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

3A

65

3

65

B14

65

4

21

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

105

65

6 83

5

3

2-M3 x 05 port

M3 x 05 with plug

4-M3 x 05 depth 4

Φ3 +0030 depth 18

C

D

4

9

14

E

3+0

03

0de

pth

18

2-Φ3H8 +00140 depth 3 3A

10

55

9F55

2-Φ34

2-M3 x 05 depth 55

14

112

7 08

20 14

9

Φ4h

70 -0

012

Φ3

-00

02-0

014

25 18

211149G

365

95

Note Refer to Page 46 for switch installation position dimensions

3A

65 652-M3 x 05 with plug2-M2 x 04 depth 3(for switch rail installation)

42

1H14

36

5

2-Φ34

2-M2 x 04 depth 25(for magnet installation)

Φ3 +0030 depth 18

4-M3 x 05 depth 4

3+0

03

0de

pth

18

ID

4

9

14

E

583

2-M3 x 05 depth 6

36

LCM-ASeriesDimensions

Dimensions

LCM-A-6-L (piping direction left)bull

With magnet and cylinder switchbull

Dowel pin (-J)bull

With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 54 35 35 35 5410 48 25 44 16 54 35 35 35 5415 53 30 49 59 40 40 40 59

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 46: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

4 A

8

4 8

B 14

8

5 3

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

683

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 34 A

55

55F9

2-Φ45

2-M3 x 05 depth 55

16

14

125

808

16 24

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

29 114 9 G

425

95

A4

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

5 3

H 14

4

8

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D

4

18

E

4 83

Note Refer to Page 46 for switch installation position dimensions

2-M3 x 05 depth 6

37

LCM-ASeries

Dimensions

LCM-A-8-R (piping direction right)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 47: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

4A

8

48

B14

8

53

2-M3 x 05 with plug2-M2 x 04 depth 3 (for switch rail installation)

2-M2 x 04 depth 25 (for magnet installation)

75

6 83

4

15

2-M3 x 05 piping port

M3 x 05 with plug

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

C

D

4

18

E

3+0

03

0de

pth

28

2-Φ3H8 +0014 0 depth 3 4A

55

9F55

2-Φ45

2-M3 x 05 depth 55

16

14

125

8 08

24 16

33

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

291149G

425

95

4A

8 82-M3 x 05 with plug

2-M2 x 04 depth 3(for switch rail installation)

53

H14

48

2-Φ45

2-M2 x 04 depth 25(for magnet installation)

Φ3 +003 0 depth 28

4-M3 x 05 depth 5

3+0

03

0de

pth

28

I

D4

18

E

483

2-M3 x 05 depth 6

Note Refer to Page 46 for switch installation position dimensions

38

LCM-ASeriesDimensions

Dimensions

LCM-A-8-L (piping direction left)bull

With magnet and cylinder switchbull With buffer (-B)bull

Stroke length A B C D E F G H I

5 48 25 44 16 56 35 35 35 5410 48 25 44 16 56 35 35 35 5415 58 35 54 26 66 45 45 45 6420 58 35 54 26 66 45 45 45 64

Dowel pin (-J)bull

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 48: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

39

JIS symbol

Linear slide cylinder double acting single rod type clean room specifications

LCM -P73 Series

Bore size Φ45 Φ6 Φ8

SpecificationsDescriptions LCM -P73Bore size mm Φ45 Φ6 Φ8Actuation Double actingWorking fluid Compressed airMax working pressure MPa 07Min working pressure MPa 02 015Withstanding pressure MPa 105Ambient temperature degC 0 to 60Port size M3

Stroke tolerance mm +100

Working piston speed mms 30 to 300Cushion None Rubber cushionedLubrication Not availableAllowable energy absorption J Refer to table on Page 4 in the Introduction

Stroke lengthBore size (mm) Standard stroke length (mm) Min stroke length of types with

switch (mm)Φ45 5 10

5Φ6 5 10 15Φ8 5 10 15 20

Note 1 Other than standard stroke length is not available

Switch specifications

Note 1 The maximum load current 20mA is applied at 25degC The current will be lower than 20mA if ambient temperature around switch is higher than 25degC (5 to 10mA at 60degC)

Descriptions Proximity 2-wire Proximity 3-wireF2HF2V F2YHF2YV F3HF3V F3YHF3YV

Applications Programmable controller Programmable controller and relayOutput type - NPN outputPower voltage - 10 to 28 VDCLoad voltage 10 to 30 VDC 24 VDC plusmn10 30 VDC or lessLoad current 5 to 20mA (Note 1) 100mA or less 50mA or less

Light LED (ON lighting)

RedGreen LED (ON lighting)

LED (ON lighting)

RedGreen LED (ON lighting)

Leakage current mA or less 10μA or less

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 49: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

40

LCM-P73SeriesSpecifications

Cylinder weightStroke length (mm) 5 10 15 20 Additional

weight

Bore size (mm)

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

With magnet + without switch rail

With magnet + switch rail

Weight per

switchΦ45 45 49 45 49 - - - - 10Φ6 61 66 61 66 69 75 - - 10Φ8 87 9 87 9 108 114 108 114 10

Unit g

Theoretical thrust tableBore size (mm) Operation

directionWorking pressure MPa

02 03 04 05 06 07

Φ45Push 32 48 64 80 95 111Pull 26 38 51 64 77 90

Φ6Push 56 85 113 141 169 197Pull 42 64 85 106 127 148

Φ8Push 101 151 201 252 302 352Pull 86 130 173 216 259 302

Unit N

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 50: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

41

LCM-P73Series

E Switch quantity

D Switch model no

A Bore size

B Stroke length

How to orderWithout switchbull

C Piping direction

With switchbull

F Option

G Clean room spec G Clean room specificationsP73 Vacuum treatment

Symbol DescriptionsA Bore size (mm)

45 Φ456 Φ68 Φ8

B Stroke length (mm)Bore size

Φ45 Φ6 Φ85 5

10 1015 15 -20 20 - -

C Piping directionR Right viewed from rod endL Left viewed from rod end

E Switch quantityR One on rod endH One on head endD Two

F OptionM Note With magnetF1 Note 1 2 With magnet + switch rail (one switch groove)F2 Note With magnet + switch rail (two switch grooves)J Dowel pin attached ( indicates pin number)

Note on model no selectionNote 1 Selection not required when designating the switch type

Note 2 Selectable if Φ45 is selected

ltExample of model numbergt

LCM-6-10-R-F2H-R-J2P73Model Linear slide cylinder double actingA Bore size Φ6mmB Stroke length 10 mmC Piping direction Right viewed from rod endD Switch model no Proximity switch F2H lead wire 1mE Switch quantity One on rod endF Option Dowel pin attached (two pcs)G Clean room specifications Vacuum treatment

R6 10 J2 P73LCM

F2HR R6 10 J2 P73LCM

D Switch model noAxial lead

wireRadial lead

wire Contact Indicator Lead wire

F2H F2V

Proximity

One color indicator

type

2-wire

F3H F3V 3-wire

F2YH F2YV Two color indicator

type

2-wire

F3YH F3YV 3-wire

Lead wire lengthBlank m (standard)

3 3m (option)

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 51: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

42

LCM-P73SeriesInternal structure and parts list

Internal structure and parts list

LCM-45-P73bull LCM-68-P73bull

LCM-45 to 8-F-P73 with magnet and switch railbull Dowel pinbull

Parts listNo Parts name Material Remarks No Parts name Material Remarks

Floating bush A Stainless steel 3 Guard Acetar resin Bolt Stainless steel 14 Stop plate Stainless steel3 End plate Aluminum alloy 15 Machine screw Stainless steel4 O ring Nitrile rubber 16 Machine screw Stainless steel5 Floating bush B Stainless steel 7 Dust collection block Aluminum alloy6 Rod cover Acetar resin 18 Cushion rubber Urethane rubber (Φ6 Φ8)7 Rod packing seal Nitrile rubber 9 Hexagon socket head cap screw Stainless steel8 Cylinder body Stainless steel 20 Switch rail Aluminum alloy9 Slide table Stainless steel Plate Aluminum alloy

10 Piston Stainless steel Hexagon socket head cap screw Stainless steel Piston packing seal Nitrile rubber 3 Magnet Plastic O ring Nitrile rubber 24 Dowel pin Steel

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 52: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

4-M25 x 045 depth 35 Φ3 +003 0 depth 25 16

8 39

45 20

5

3

35

7

3 +003 0

depth 25

-L M3 x 05 dust collection port(With plug for-R)

25 14 16

3

2-M3 x 05 L side piping port (Note 1)

10

18

65

94

2-M3 x 05 depth 45

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

47

16

()

43

16

4-42

4-Φ21

Φ3

+00

3 0

dept

h 1

816 05

4 55

9

3 2-M2 x 04 depth 25

-R M3 x 05 dust collection port(With plug for -L)

285 3

25 14 16

3

8 28

21

32

35

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

115

95

3 34

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

65

95

(If two switches installed) (If one switch installed)

Note Refer to Page 46 for switch installation position dimensions

43

LCM-P73Series

Dimensions

LCM-45-P73bull

With magnet and cylinder switch (piping direction -R)bull

Dowel pin (-J)bullWith magnet and cylinder switch (piping direction -L)bull

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 53: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

45

2-M3 x 05 L side piping port (Note 1)

14 20

7

112

2-M3 x 05 depth 55

4-M3 x 05 depth 4

Φ3 +003 0 depth 18

A

B

()

4

14

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 1

8705

4 75

3 2-M25 x 045 depth 25

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

21

45

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 5 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

14 9

3 +003 0

depth 25

32

115

95

14 H

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

44

LCM-P73SeriesDimensions

Dimensions

LCM-6-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 54 35 34 45 40

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 54: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

-L M3 x 05 dust collection port(With plug for -R)

25 145 E

5

2-M3 x 05 L side piping port (Note 1)

14

16 24

8

125

2-M3 x 05 depth 55

4-M3 x 05 depth 5

Φ3 +003 0 depth 28

A

B

()

418

C

4-5

4-Φ26

Φ3

+00

3 0

dept

h 2

87 05

5 85

14

4 2-M3 x 05 depth 3

-R M3 x 05 dust collection port(With plug for -L)

D 14

25 145 E

8 F

3

5

2-M2 x 04 depth 25 (for magnet installation both sides)

2-M2 x 04 depth 3 (for switch rail installation both sides)

2-M3 x 05 R side piping port (Note 1)

4-M3 x 05 depth 55 Φ3 +003 0 depth 25 C

9 G

55 20

5

4

18 3

3 +003 0

depth 25

4

55

55

55

114

95

14 H09

Φ4h

7 0 -0

012

Φ3

-00

02-0

014

25 18

(Note 1) A plug is assembled on the opposite side of piping port indicated in the model no

Note Refer to Page 46 for switch installation position dimensions

45

LCM-P73Series

Dimensions

LCM-8-P73bull

Dowel pin (-J)bull

With magnet and cylinder switch (piping direction -R)bull

With magnet and cylinder switch (piping direction -L)bull

Stroke length A B C D E F G H

5 49 16 16 30 16 9 40 3510 49 16 16 30 16 9 40 3515 59 26 26 40 26 39 50 4520 59 26 26 40 26 39 50 45

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 55: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

Bore size (mm) Stroke length RD HD B1 color indicator type 2 color indicator type

φ455

7- -

10 7 17 62

φ65

7- -

10 7 17 6215 17 62

φ8

5

7

- -10 7 17 6215 - -20 7 17 62

Bore size (mm) Stroke length RD HD A1 color indicator type 2 color indicator type

φ455 7

27 72

10 7 7

φ65 3 18

10 8 1815 8 3

φ8

5 3 1810 8 1815 3 2820 8 28

(Projecting length for axial lead wire)

(Projecting length for axial lead wire)

HD 197

A

RD 197

HD197

B

RD197

46

LCM-P73Series

LCM Series common Switch installation and projection dimensions

For rear lead wire outletbull

For front lead wire outletbull

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 56: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

M moment M3 momentL L

Allowable load mass1000

100

10

Load

mas

s(g

)

0 01 02 03 04 05 06Max speed v (ms)

LCM-8

LCM-6

LCM-45

Note that when butting the work at a point offset from the guide section in the middle of the stroke a large moment will be generated by the thrust of the mini guide slider

LCMSeries

47

STEP-1Confirm that the load moment in each direction is below the allowable value in all strokes

Model no M1 M2 M3LCM--45 024 022 029LCM--6 028 023 034LCM--8 028 038 034

Selection guide

Allowable momentbullDirection of moment guide center position Xbull

Guide center position dimensionsbull

Model no Stroke length

XStandard With buffer Clean room spec

LCM--455

30 40 3510

LCM--65

315 415 3651015 365 465 415

LCM--8

5315 415 365

1015

415 515 46520

mm

STEP-2Confirm that dynamic energy from cylinder load weight and piston speed is less than allowable energy absorption

Bore size Φ45 Φ6 Φ8Allowable

energy absorption J

159times10-3 283times10-3 502times10-3

Nm

L

M W

xL

M W

L3

M3 W

xL3

M3 W

M W M W

LL

Direct

ion Figure Formula

M1

mom

ent

M1=L1timesW

M2

mom

ent

M2=L2timesW

M3

mom

ent

M3=L3timesW

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 57: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

A

A

D

B

G CE

AF

AA sectional view

Disp

lacem

ent a

ngle M moment

Disp

lacem

ent

angle

M moment

M3 moment

() 0025

002

0015

0005

0

Bending moment (Nm)0 005 01 015 02 025 03

LCM-45

LCM-6 8

0010

Bending moment (Nm)0 005 01 015 02 025 03 035 04

002003004005006007008

LCM-45LCM-6

LCM-8

0005

0

Bending moment (Nm)0 005 01 015 02 025 03 035 04

001

0015

002

0025

LCM-45

LCM-6 8

Disp

lacem

ent a

ngle

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

()

Disp

lacem

ent a

ngle

LCMSeries

48

Technical data

Accuracy of slide table

Technical data

Descriptions LCM--45 to 8

ParallelismC plane against A plane 003D plane against B plane 003

Sliding parallelismC plane against A plane 0005D plane against B plane 0005

Tolerance of E plusmn005Tolerance of F plusmn005Tolerance of G plusmn005

mm

Displacement angle of slide table caused by bending moment (reference value)

M moment

M moment

M3 moment

49

50

Page 58: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

49

50

Page 59: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6

50

Page 60: Compact/highly accurate actuator New product …ckd.co-site.jp/ad/biochemical/Catalog/CC-848A-1.pdfCompact, highly accurate actuator LCM-P LCM Bore size Stroke length (mm) Ф4.5 Ф6