compact ups systems for high power network rack applications

7
Compact UPS Systems for High Power Network Rack Applications 5- 6- 8- 10kVA Today’s converged networks require increased availability and reliability. This has created a need for higher density power protection systems that adapt to mixed load voltages and plug types, while remaining easy to install and maintain. New IT technologies, such as VoIP and PoE, have greatly increased power demands. Unfortunately, as these requirements have risen, the amount of space available for your protected equipment and related power support systems has not. Liebert GXT3 5kVA & 6kVA models are true on-line UPS systems that provide internal batteries and dual output voltage. They are an ideal fit for applications where the power requirements are demanding – but rack space is limited – delivering 5kVA (4kW) or 6kVA (4.8kW) of power in a single 4U size cabinet. This cabinet size is well suited for installations such as network closets or small data centers. Liebert GXT3 8kVA & 10kVA units offer a flexible solution for protecting rack-mount equipment, including VoIP and PoE. Especially designed for use with the new generation of high power switches, these compact UPS systems pack 8kVA (7.2kW) or 10kVA (9kW) of power into a 6U rack/tower package with flexible output voltage and optional output distribution. The UPS includes built-in, user-replaceable batteries for up to four minutes of run time at full load. Key Benefits: Rack/tower configuration in one form factor Rotatable display Automatic frequency detection User replaceable hot-swappable internal batteries Additional runtime with additional battery cabinets Liebert IntelliSlot communications port Multiple outpost possibilities (hardwired and receptacles) Includes Windows-based configuration program Built-in USB communications for use with Liebert MultiLink Automated Shutdown Software Built-in closure signals Emergency Power Off (EPO) Wider input voltage window minimizes battery use Internal automatic and manual bypass (integrated) Self-diagnostics Standard two-year replacement warranty Uses minimum rack space Shields batteries from heat generating electronic components Battery C\cutoff voltage to prevent from over-discharge of batteries Up to 0.9 Power Factor Applications: LAN & WAN Servers Network Equipment IP Telephony Deployments Office Telecommunications systems ISDN & frame relay applications Test and Diagnostic Equipment

Upload: priyanka236

Post on 28-Dec-2015

20 views

Category:

Documents


0 download

DESCRIPTION

high power networks

TRANSCRIPT

Page 1: Compact UPS Systems for High Power Network Rack Applications

Compact UPS Systems for High Power Network Rack Applications

5- 6- 8- 10kVAToday’s converged networks require increased availability and reliability.  This has created a need for higher density power

protection systems that adapt to mixed load voltages and plug types, while remaining easy to install and maintain.  New IT

technologies, such as VoIP and PoE, have greatly increased power demands.  Unfortunately, as these requirements have risen, the

amount of space available for your protected equipment and related power support systems has not.

Liebert GXT3 5kVA & 6kVA models are true on-line UPS systems that provide internal batteries and dual output voltage.  They are

an ideal fit for applications where the power requirements are demanding – but rack space is limited – delivering 5kVA (4kW) or

6kVA (4.8kW) of power in a single 4U size cabinet.  This cabinet size is well suited for installations such as network closets or small

data centers.

Liebert GXT3 8kVA & 10kVA units offer a flexible solution for protecting rack-mount equipment, including VoIP and PoE.  Especially

designed for use with the new generation of high power switches, these compact UPS systems pack 8kVA (7.2kW) or 10kVA (9kW)

of power into a 6U rack/tower package with flexible output voltage and optional output distribution.  The UPS includes built-in, user-

replaceable batteries for up to four minutes of run time at full load.

Key Benefits:

Rack/tower configuration in one form factor

Rotatable display

Automatic frequency detection

User replaceable hot-swappable internal batteries

Additional runtime with additional battery cabinets

Liebert IntelliSlot communications port

Multiple outpost possibilities (hardwired and receptacles)

Includes Windows-based configuration program

Built-in USB communications for use with Liebert MultiLink Automated Shutdown Software

Built-in closure signals

Emergency Power Off (EPO)

Wider input voltage window minimizes battery use

Internal automatic and manual bypass (integrated)

Self-diagnostics

Standard two-year replacement warranty

Uses minimum rack space

Shields batteries from heat generating electronic components

Battery C\cutoff voltage to prevent from over-discharge of batteries

Up to 0.9 Power Factor

Applications:

LAN & WAN Servers

Network Equipment

IP Telephony Deployments

Office Telecommunications systems

ISDN & frame relay applications

Test and Diagnostic Equipment

Banks

Micro Processor-controlled Equipment

Popular UPS Models Include:

Page 2: Compact UPS Systems for High Power Network Rack Applications

GXT3-5000RT208 – 5000VA/4000W Rack/Tower, 120/208V hardwired input/output

GXT3-6000RT208 – 6000VA/4800W Rack/Tower, 120/208V hardwired input/output

GXT3-6000RTL630 – 6000VA/4800W Rack/Tower, 208V hardwired input/output

GXT3-8000RT208 – 8000VA/7200W Rack/Tower, 120/208V hardwired input/output

GXT3-10000RT208 – 10000VA/9000W Rack/Tower, 120/208V hardwired input/outputPower Distribution Box Options – GXT3-5000RT208, GXT3-6000RT208, GXT3-6000RTL630

PD2-HDWR – Hardwire terminal block 3W + G (L-L-N-G) input/output

PD2-HDWR-MBS – Hardwire terminal block 3W + G (L-L-N-G) input/output

PD2-001 – L14-30P input on 3.2M cord, (4) 5-20R, (1) L14-30, (1) L6-30R output

PD2-002 – L14-30P input on 3.2M cord, (2) 5-20R, (2) L6-20R output

PD2-003 – L14-30P input on 3.2M cord, (4) 5-20R, (2) L6-30R output

PD2-004 – L14-30P input on 3.2M cord, (4) L5-20R, (2) L5-30R output

PD2-005 – L14-30P input on 3.2M cord, (4) L5-20R, (2) L6-20R output

PD2-006 – L14-30P input on 3.2M cord, (4) L6-20R output

PD2-L630 – L6-30P input on 3.2M cord, (2) L6-20R, (2) L6-30R outputPower Distribution Box Options – GXT3-8000RT208 and GXT3-10000RT208

PD2-101 – Hardwire terminal block 3W + G (L-L-N-G) input, (2) L6-30, (8) 5-20R output

PD2-102 – Hardwire terminal block 3W + G (L-L-N-G) input, (4) L6-20R, (4) 5-20R output

PD2-103 – Hardwire terminal block 3W + G (L-L-N-G) input, (4) 5-20R, (4) L6-30R output

PD2-104 – Hardwire terminal block 3W + G (L-L-N-G) input, (4) 5-20R, (2) L6-30R, (2) L6-20R output

PD2-105 – Hardwire terminal block 3W + G (L-L-N-G) input, (4) 5-20R, (2) L5-30R, (2) L5-20R output

PD2-106 – Hardwire terminal block 3W + G (L-L-N-G) input, (4) L6-20R, (4) L5-20R outputExternal Battery Cabinet Options:

GXT3-5000RT208 – use GXT3-144VBATT

GXT3-6000RT208 – use GXT3-144VBATT

GXT3-6000RTL630 – use GXT3-240VBATTUL

GXT3-8000RT208 – use GXT3-288RTBATT

GXT3-10000RT208 – use GXT3-288RTBATT

Liebert GXT3 – 500VA – 3000VAReliable On-Line UPS Protection in a Compact 2U Package

700- 1000- 1500- 2000- 3000VALiebert GXT3 is a true on-line UPS that delivers continuous, high-quality AC power to IT equipment with no break when transferring

to battery.  It protects equipment from virtually all power disturbances due to blackouts, brownouts, sags, surges or noise

interference.  The UPS is available in rack/tower and mini-tower configurations.

Liebert GXT3 requires just a slim 2U of rack space providing the capabilities of a physically larger system.  Get up to 3kVA of

capacity battery backup, in 120V or 208V systems.  External battery cabinets may be added for extended run time.

Key Benefits:

Up to seven battery-backed outlets

Rotatable display panel

Page 3: Compact UPS Systems for High Power Network Rack Applications

Automatic frequency sensing

Mounting flexibility

Multiple Communications Options (SNMP/WEB & USB)

Compatible with Liebert MultiLink, Liebert Nform, Liebert Multiport, Liebert Intellislot Relay Interface card

Advance early warning of UPS systems status

Scalable runtime with up to four external battery modules

Full sequenced battery testing

User replaceable hot swappable batteries

0.9 Output Power Factor

Wider input voltage window

Intelligent fan operation

Efficient operation

2-Year warranty protection

Ideally Suited For:

PCs

Network workstations

Servers

Network closets

Large network peripherals

VoIP

Popular Models Include:

GXT3-500RT120 – 500VA/450W Rack/Tower, 120V 5-15P input, 120V (6) 5-15R output, 17 minutes of runtime

GXT3-700RT120 – 700VA/630W Rack/Tower, 120V 5-15P input, 120V (6) 5-15R output, 11 minutes of runtime

GXT3-1000RT120 – 1000VA/900W Rack/Tower, 120V 5-15P input, 120V (6) 5-15R output, 7 minutes of runtime, TAA Compliant

GXT3-1000MT120 – 1000VA/900W Rack/Tower, 120V 5-15P input, 120V (6) 5-15R output, 7 minutes of runtime

GXT3-1500RT120 – 1500VA/1350W Rack/Tower, 120V 5-15P input, 120V (6) 5-15R output, 4 minutes of runtime, TAA Compliant

GXT3-2000RT120 – 2000VA/1800W Rack/Tower, 120V 5-20P input, 120V (6) 5-20R output, 3 minutes of runtime, TAA Compliant

GXT3-3000RT120 – 3000VA/2700W Rack/Tower, 120V L5-30P input, 120V (1) L5-30R, (6) 520R output, 3 minutes of runtime, TAA

Compliant

GXT3-3000RT208 – 3000VA/2700W Rack/Tower, 208V L6-20P input, 208V (1) L6-20R, (2) L6-15R output, 3 minutes of runtime

Liebert GXT3 – 5kVA – 10kVA UPSCompact UPS Systems for High Power Network Rack Applications

5- 6- 8- 10kVAToday’s converged networks require increased availability and reliability.  This has created a need for higher density power

protection systems that adapt to mixed load voltages and plug types, while remaining easy to install and maintain.  New IT

technologies, such as VoIP and PoE, have greatly increased power demands.  Unfortunately, as these requirements have risen, the

amount of space available for your protected equipment and related power support systems has not.

Liebert GXT3 5kVA & 6kVA models are true on-line UPS systems that provide internal batteries and dual output voltage.  They are

an ideal fit for applications where the power requirements are demanding – but rack space is limited – delivering 5kVA (4kW) or

6kVA (4.8kW) of power in a single 4U size cabinet.  This cabinet size is well suited for installations such as network closets or small

data centers.

Page 4: Compact UPS Systems for High Power Network Rack Applications

Liebert GXT3 8kVA & 10kVA units offer a flexible solution for protecting rack-mount equipment, including VoIP and PoE.  Especially

designed for use with the new generation of high power switches, these compact UPS systems pack 8kVA (7.2kW) or 10kVA (9kW)

of power into a 6U rack/tower package with flexible output voltage and optional output distribution.  The UPS includes built-in, user-

replaceable batteries for up to four minutes of run time at full load.

Key Benefits:

Rack/tower configuration in one form factor

Rotatable display

Automatic frequency detection

User replaceable hot-swappable internal batteries

Additional runtime with additional battery cabinets

Liebert IntelliSlot communications port

Multiple outpost possibilities (hardwired and receptacles)

Includes Windows-based configuration program

Built-in USB communications for use with Liebert MultiLink Automated Shutdown Software

Built-in closure signals

Emergency Power Off (EPO)

Wider input voltage window minimizes battery use

Internal automatic and manual bypass (integrated)

Self-diagnostics

Standard two-year replacement warranty

Uses minimum rack space

Shields batteries from heat generating electronic components

Battery C\cutoff voltage to prevent from over-discharge of batteries

Up to 0.9 Power Factor

Applications:

LAN & WAN Servers

Network Equipment

IP Telephony Deployments

Office Telecommunications systems

ISDN & frame relay applications

Test and Diagnostic Equipment

Banks

Micro Processor-controlled Equipment

Popular UPS Models Include:

GXT3-5000RT208 – 5000VA/4000W Rack/Tower, 120/208V hardwired input/output

GXT3-6000RT208 – 6000VA/4800W Rack/Tower, 120/208V hardwired input/output

GXT3-6000RTL630 – 6000VA/4800W Rack/Tower, 208V hardwired input/output

GXT3-8000RT208 – 8000VA/7200W Rack/Tower, 120/208V hardwired input/output

GXT3-10000RT208 – 10000VA/9000W Rack/Tower, 120/208V hardwired input/output

Power Distribution Box Options – GXT3-5000RT208, GXT3-6000RT208, GXT3-6000RTL630PD2-HDWR – Hardwire terminal block 3W + G (L-L-N-G) input/outputPD2-HDWR-MBS – Hardwire terminal block 3W + G (L-L-N-G) input/outputPD2-001 – L14-30P input on 3.2M cord, (4) 5-20R, (1) L14-30, (1) L6-30R outputPD2-002 – L14-30P input on 3.2M cord, (2) 5-20R, (2) L6-20R outputPD2-003 – L14-30P input on 3.2M cord, (4) 5-20R, (2) L6-30R outputPD2-004 – L14-30P input on 3.2M cord, (4) L5-20R, (2) L5-30R outputPD2-005 – L14-30P input on 3.2M cord, (4) L5-20R, (2) L6-20R outputPD2-006 – L14-30P input on 3.2M cord, (4) L6-20R outputPD2-L630 – L6-30P input on 3.2M cord, (2) L6-20R, (2) L6-30R output

Page 5: Compact UPS Systems for High Power Network Rack Applications

Power Distribution Box Options – GXT3-8000RT208 and GXT3-10000RT208

PD2-101 – Hardwire terminal block 3W + G (L-L-N-G) input, (2) L6-30, (8) 5-20R output

PD2-102 – Hardwire terminal block 3W + G (L-L-N-G) input, (4) L6-20R, (4) 5-20R output

PD2-103 – Hardwire terminal block 3W + G (L-L-N-G) input, (4) 5-20R, (4) L6-30R output

PD2-104 – Hardwire terminal block 3W + G (L-L-N-G) input, (4) 5-20R, (2) L6-30R, (2) L6-20R output

PD2-105 – Hardwire terminal block 3W + G (L-L-N-G) input, (4) 5-20R, (2) L5-30R, (2) L5-20R output

PD2-106 – Hardwire terminal block 3W + G (L-L-N-G) input, (4) L6-20R, (4) L5-20R output

External Battery Cabinet Options:

GXT3-5000RT208 – use GXT3-144VBATT

GXT3-6000RT208 – use GXT3-144VBATT

GXT3-6000RTL630 – use GXT3-240VBATTUL

GXT3-8000RT208 – use GXT3-288RTBATT

GXT3-10000RT208 – use GXT3-288RTBATT

Liebert NX On-Line UPS 10 – 30kVAUPS for Small and Medium Business

Liebert NX: 10kVA, 15kVA, 20kVA, 30kVA – Flexible, Reliable and EconomicalThe Liebert NX family of UPS systems combines numerous technology advances and innovations to create a power system that

combines high performance, compact size, reliability and cost-efficiency.  Liebert NX models are available with characteristics to fit

the flexibility and availability needs of different sites.

Flexibility:

Parallel units that are the same or different capacities for greater flexibility in managing power growth

Generator compatible

Power communications available through Liebert IntelliSlot Web Card LB and Liebert MultiLink shutdown software

Large and user-friendly LCD display provides operating information in twelve languages

Internal automatic bypass transfers load to bypass in the unlikely event that a fault occurs in the UPS.  Optional wrap-around

maintenance bypass allows the UPS to be powered down or taken out of service without disconnecting power to the load Front accessibility allows easy servicing of critical components, self-diagnostics and various monitoring options

Optional Bypass Distribution Cabinets

Page 6: Compact UPS Systems for High Power Network Rack Applications

Higher Availability:

Wider input voltage window and frequency tolerances help to minimize transfer to battery, reducing the number of charging and

discharging cycles High overload rating capable of clearing a 20A branch circuit breaker

True on-line double conversion technology protects and conditions against a full range of power irregularities, requiring fewer

transfers to battery Advanced inverter control technology provides the highest output power quality to maximize efficiency and operating life of

connected equipment Load Bus Synchronization provides the capability to synchronize the outputs of two independent UPS modules when they are

configured as a redundant system feeding independent distribution paths. An intelligent battery management algorithm monitors the battery to detect any premature battery failure

Lowest Total Cost of Ownership:

Soft-switching technology optimizes operation with the same high efficiency at 40% utilization as at 100% utilization

Adaptive input voltage window results in fewer hits on the battery

The unit’s compact footprint requires less floor space, leaving you with more room for other equipment

temperature-compensated battery charging extends battery life

Softscale technology allows you to purchase the capacity you need now and economically upgrade in the future without the expense

of additional cabinets or floorspaceLiebert NX 10kVA – 30kVA is best suited for:

Small to mid-size data centers

Server rooms

Production

Labs and Testing

Telecommunications

Process Control

Point-Of-Sale

Other sensitive electronics