commissioning of electron cooling in...

5
COMMISSIONING OF ELECTRON COOLING IN CSRM* X.D. Yang #,1 , V.V. Parkhomchuk 2 , W.L. Zhan 1 , J.W. Xia 1 , H.W. Zhao 1 , G.Q Xiao 1 , Y.J. Yuan 1 , M.T. Song 1 , Y. Liu 1 , J.C. Yang 1 , L.J. Mao 1 , J. Li 1 , G.H. Li 1 , D.Q. Gao 1 , Z.Z. Zhou 1 , Y. He 1 , W. Zhang 1 , X. T. Yang 1 , J.H. Zheng 1 , R.S. Mao 1 , T.C. Zhao 1 1. Institute of Modern Physics, 730000 Lanzhou, CAS, China 2. Budker institute of Nuclear Physics,630090 Novosibirsk, RAS, Russia Abstract A new generation electron cooler has started operation in the heavy ion synchrotron CSRm which is used to increase the intensity of heavy ions. Transverse cooling of the ion beam after horizontal multiturn injection allows beam accumulation at the injection energy. After optimization of the accumulation process an intensity increase in a synchrotron pulse by more than one order of magnitude has been achieved. In given accumulation time interval of 10 seconds, 10 8 particles have been accumulated and accelerated to the final energy. The momentum spread after accumulation and acceleration in the 10 -4 range has been demonstrated in five species of ion beams. Primary measurements of accumulation process varying with electron energy, electron beam current, electron beam profile, expansion factor and injection interval have been performed. The lifetimes of ion beam in the presence of electron beam were roughly measured with the help of DCCT signal. INSTRUCTION HIRFL-CSR is a new ion cooler-storage-ring system in IMP China. It consists of a main ring (CSRm) and an experimental ring (CSRe). The two existing cyclotrons SFC (K=69) and SSC (K=450) of the Heavy Ion Research Facility in Lanzhou (HIRFL) are used as its injector system. The heavy ion beams from HIRFL is injected into CSRm, then accumulated, e-cooled and accelerated, finally extracted to CSRe for internal-target experiments and other physics experiments. Table 1: Parameters of the CSRm electron cooler Maximum electron energy 35 keV Maximum electron current 3A Gun perveance 29 μP Cathode diameter 29mm Current collection efficiency 99.99% Maximum magnetic field in gun section 0.25T Maximum magnetic field in cooling section 0.15T Field parallelism in cooling section 4×10 -5 Effective length of cooling section 3.4m Vacuum pressure 3×10 -11 mbar CSRm is a 161m circumference cooler storage ring with sixteen 22.5 degree H-type bending dipole magnets. The maximum betatron functions are 15.3m and 30.5m in horizontal and vertical respectively. The maximum dispersion is 5.4m, and the dispersion at injection point is 4m. The betatron functions at electron cooler are 10m and 17m in the two transverse directions respectively, the dispersion is zero here. The emittance of ion beam from SFC and SSC is about 20 mmmrad and 10 mmmrad, and the acceptance of CSRm is about 150 mmmrad. Two modes of injection are used in CSRm, stripping for lighter ions and repeated multiturn for heavier ones. The accumulation duration of CSRm is about 10s, and the acceleration time of CSRm is nearly 3s, and the one whole cycle period is about 17s. In CSRm, the electron cooling device plays an important role in the heavy ion beam accumulation at injection energy. The new state-of-the-art electron cooling device was designed and manufactured in the collaboration between BINP and IMP, it has three distinctive characteristics, namely high magnetic field parallelism in cooling section, variable electron beam profile and electrostatic bending in toroids. The main parameters are listed in table 1. In 2005 the main construction of the CSR project was completed, and from then the preliminary commissioning of CSRm was performed, including the first turn commissioning as a beam line, the stripping injection, and the zero-bumping orbit test, fixed-bumping orbit test with four in-dipole coils, bumping orbit test, C-beam accumulation and some investigations of the closed orbit with BPM. Shortly after last workshop of COOL2005, the cooler started routine operation during CSR commissioning. Up to now five species of ion were cooled and accumulated with the help of electron cooling. In this paper the recent results of commissioning of CSRm and its cooler are presented. The previous results have been given in the APAC2007-THXMA03 [1] BEAM DIAGNOSTICS The closed orbit is monitored by 16 shoebox-shaped BPMs, the length of electrodes is 150mm, the cross- section is rectangular, and the width and height are 170mm and 100mm respectively. Two additional cylindrical BPMs were installed at the ends of cooling section to measure the positions of electron beam and ion beam. A Schottky pickup was placed behind the cooler, the length of the plate electrodes is 395mm, and the widths are 160mm in horizontal and 100mm in vertical directions, the gaps between electrodes are 110mm in vertical and 160mm in horizontal. A DCCT developed by company Bergoz is used to monitor the ion beam current in the ring, with precision of about 0.5μA. The direct determination of beam’s transverse emittance was presently ruled out due to the magnesium jet monitor was out of order during commission. In order to measure the work-point, the Schottky pickup electrodes were used to ___________________________________________ *Work supported by the central government of China # [email protected] Proceedings of COOL 2007, Bad Kreuznach, Germany TUM1I02 59

Upload: dohanh

Post on 21-Apr-2018

218 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Commissioning of Electron Cooling in CSRmaccelconf.web.cern.ch/AccelConf/cl07/papers/tum1i02.pdfexcite the ion beam, a BPM was used to monitor the Schottky signal, the length of its

COMMISSIONING OF ELECTRON COOLING IN CSRM* X.D. Yang#,1, V.V. Parkhomchuk2, W.L. Zhan1, J.W. Xia1, H.W. Zhao1, G.Q Xiao1,Y.J. Yuan1, M.T. Song1, Y. Liu1, J.C. Yang1, L.J. Mao1, J. Li1, G.H. Li1, D.Q. Gao1,

Z.Z. Zhou1, Y. He1, W. Zhang1 , X. T. Yang1, J.H. Zheng1, R.S. Mao1, T.C. Zhao1

1. Institute of Modern Physics, 730000 Lanzhou, CAS, China 2. Budker institute of Nuclear Physics,630090 Novosibirsk, RAS, Russia

AbstractA new generation electron cooler has started operation

in the heavy ion synchrotron CSRm which is used toincrease the intensity of heavy ions. Transverse cooling ofthe ion beam after horizontal multiturn injection allowsbeam accumulation at the injection energy. Afteroptimization of the accumulation process an intensityincrease in a synchrotron pulse by more than one order ofmagnitude has been achieved. In given accumulation timeinterval of 10 seconds, 108 particles have beenaccumulated and accelerated to the final energy. Themomentum spread after accumulation and acceleration inthe 10-4 range has been demonstrated in five species ofion beams. Primary measurements of accumulationprocess varying with electron energy, electron beamcurrent, electron beam profile, expansion factor andinjection interval have been performed. The lifetimes ofion beam in the presence of electron beam were roughly measured with the help of DCCT signal.

INSTRUCTIONHIRFL-CSR is a new ion cooler-storage-ring system in

IMP China. It consists of a main ring (CSRm) and an experimental ring (CSRe). The two existing cyclotronsSFC (K=69) and SSC (K=450) of the Heavy Ion ResearchFacility in Lanzhou (HIRFL) are used as its injectorsystem. The heavy ion beams from HIRFL is injected intoCSRm, then accumulated, e-cooled and accelerated,finally extracted to CSRe for internal-target experimentsand other physics experiments.

Table 1: Parameters of the CSRm electron coolerMaximum electron energy 35 keV Maximum electron current 3AGun perveance 29 μPCathode diameter 29mmCurrent collection efficiency 99.99%Maximum magnetic field in gun section 0.25TMaximum magnetic field in cooling section 0.15TField parallelism in cooling section 4×10-5

Effective length of cooling section 3.4mVacuum pressure 3×10-11mbar

CSRm is a 161m circumference cooler storage ringwith sixteen 22.5 degree H-type bending dipole magnets.The maximum betatron functions are 15.3m and 30.5m inhorizontal and vertical respectively. The maximumdispersion is 5.4m, and the dispersion at injection point is4m. The betatron functions at electron cooler are 10m and17m in the two transverse directions respectively, thedispersion is zero here. The emittance of ion beam from

SFC and SSC is about 20 mmmrad and 10 mmmrad,and the acceptance of CSRm is about 150 mmmrad.

Two modes of injection are used in CSRm, stripping forlighter ions and repeated multiturn for heavier ones. Theaccumulation duration of CSRm is about 10s, and the acceleration time of CSRm is nearly 3s, and the onewhole cycle period is about 17s.

In CSRm, the electron cooling device plays an important role in the heavy ion beam accumulation at injection energy. The new state-of-the-art electron cooling device was designed and manufactured in thecollaboration between BINP and IMP, it has threedistinctive characteristics, namely high magnetic fieldparallelism in cooling section, variable electron beamprofile and electrostatic bending in toroids. The mainparameters are listed in table 1.

In 2005 the main construction of the CSR project was completed, and from then the preliminary commissioningof CSRm was performed, including the first turncommissioning as a beam line, the stripping injection, andthe zero-bumping orbit test, fixed-bumping orbit test withfour in-dipole coils, bumping orbit test, C-beamaccumulation and some investigations of the closed orbitwith BPM.

Shortly after last workshop of COOL2005, the coolerstarted routine operation during CSR commissioning. Upto now five species of ion were cooled and accumulatedwith the help of electron cooling. In this paper the recentresults of commissioning of CSRm and its cooler arepresented. The previous results have been given in theAPAC2007-THXMA03 [1]

BEAM DIAGNOSTICSThe closed orbit is monitored by 16 shoebox-shaped

BPMs, the length of electrodes is 150mm, the cross-section is rectangular, and the width and height are170mm and 100mm respectively. Two additionalcylindrical BPMs were installed at the ends of cooling section to measure the positions of electron beam and ion beam. A Schottky pickup was placed behind the cooler,the length of the plate electrodes is 395mm, and thewidths are 160mm in horizontal and 100mm in verticaldirections, the gaps between electrodes are 110mm invertical and 160mm in horizontal. A DCCT developed bycompany Bergoz is used to monitor the ion beam currentin the ring, with precision of about 0.5μA. The directdetermination of beam’s transverse emittance was presently ruled out due to the magnesium jet monitor wasout of order during commission. In order to measure thework-point, the Schottky pickup electrodes were used to

___________________________________________

*Work supported by the central government of China #[email protected]

Proceedings of COOL 2007, Bad Kreuznach, Germany TUM1I02

59

Page 2: Commissioning of Electron Cooling in CSRmaccelconf.web.cern.ch/AccelConf/cl07/papers/tum1i02.pdfexcite the ion beam, a BPM was used to monitor the Schottky signal, the length of its

excite the ion beam, a BPM was used to monitor theSchottky signal, the length of its electrodes is smaller thanSchottky pickup electrodes. The lifetime of ion beam was measured by DCCT signal roughly. The work point ofring was monitored during the process of acceleration. Due to lack of the transverse ion beam monitors, thetransverse profile of the ion beam was not measuredduring the commissioning.

CLOSED-ORBIT CORRECTIONThe closed-orbit is monitored during acceleration by

the BPM system. 16 steering in-dipole coils, 8 pairs ofhorizontal and vertical bidirectional correction dipolesand 6 additional vertical correction dipoles are used tocorrect the closed-orbit.

The longitudinal field produced by electron cooler iscompensated by two compensation solenoids at the bothends of cooler. The transverse field introduced by thetoroids is corrected by four pairs of horizontal and verticalcorrection dipoles. The displacement and direction of ionbeam in the cooling section can be adjusted by thesedipoles.

The global closed-orbit correction was performedaccording to the ion beam decay in the ring afteraccumulation process. After turning on the magnetic field of electron cooler and related correction coils, the localclosed-orbit correction was carried out in the region of electron cooler.

BEAM ACCUMULATIONStripping jection of 12C6+

Firstly, the 7MeV/u 12C4+ was injected into CSRm fromsmall cyclotron SFC through a stripping foil withthickness of 15μg/cm2 placed in the first dipole of the ring,the average pulse intensity was about 12μA in the injection line. In the absent of magnetic field of electroncooler, the single-turn stripping injection beam was tested in CSRm with bumping orbit, the stored beam signal wasobserved from BPM signal, the closed orbit correctionwas done roughly, the machine parameter such asworking point was measured and tuned, acceleration wasattempted.

The average particle number of stored 12C6+ was about4.7×108 in one standard multiturn injection. With the helpof electron cooling of partially hollow electron beam,2.5×109 particles were accumulated in the ring after 10times injection in 10 seconds, and 2.2×109 particles were accelerated to final energy of 1GeV/u. The momentumspread of injected beam was about 1.5×10-3, after electron cooling the momentum spread rapidly reduced to 5.5×10-5

in a second at first shot, and then final momentum spreadincreased linearly with the stored particle number. TheSchottky noise signal of 12C6+ during accumulation waspresented in Figure 1, and the dependence of momentumspread upon the stored ion number was shown in Figure 2.The momentum cooling time was about 0.3sec. About1.6×1010 particles were stored in the ring after longer timeaccumulation which is displayed in Figure 3.

Figure 1: Schottky signal of 12C6+ during accumulation.

1E8 1E91E-5

1E-4

1E-3

1E8 1E9

1E-5

1E-4

1E-3

Mom

entu

m s

prea

dP/

P af

ter c

oolin

g

Number of ion N

12C6+ 7MeV/uUgrid=0.2173kVUanode=0.5859kVIelectron=74mAfexp

=3.8

P/Pinitial

=1.46*10-3

Figure 2: Momentum spread of cooled 12C6+ as a function of the stored particle number at the injection energydetermined by Schottky signal of a coasting beam in Fig.1.

Figure 3: 12C6+ beam accumulation.Multiturn jection of 12C4+

At the end of the transfer line one magnetic septum and an electrostatic septum inflector guides the beam parallel to the ring orbit; four in-dipole coils create a DC bump of 50mm amplitude at the electrostatic septum. For multiturninjection four fast bump magnets produce a timedependent bump orbit to fill the horizontal acceptance ofthe ring.

In order to test the performance of the elements for multiturn injection, repeated multiturn injection wascarried out with 7MeV/u 12C4+ without stripping. Theaverage pulse intensity was about 6μA in the injection

In

In

TUM1I02 Proceedings of COOL 2007, Bad Kreuznach, Germany

60

Page 3: Commissioning of Electron Cooling in CSRmaccelconf.web.cern.ch/AccelConf/cl07/papers/tum1i02.pdfexcite the ion beam, a BPM was used to monitor the Schottky signal, the length of its

line. Only 47% of beam intensity left after turned on thecooler magnetic field and related correction, it is smallerthan the results of SIS. The average particle number of12C4+ per pulse is about 1.2×108 in one standard multiturninjection, with the help of electron cooling of partiallyhollow electron beam, 5.8×108 particles wereaccumulated in the ring after 10 times injection in 10seconds, and 4.6×108 particles were accelerated to finalenergy of 300MeV/u. The measured lifetime of 12C4+ is 28 seconds, which is shorter comparing with 255s of 12C6+,after longer time accumulation, the particle number wassaturated at 7.0×108.

Multiturn jection of 36Ar18+

For the sake of the performance of accelerator complexof HIRFL, 22MeV/u 36Ar8+ beam extracted from SSC was stripped into 36Ar18+ by the foil with thickness of 350μg/cm2, and then injected to CSRm, the average pulseintensity was about 4μA in the injection line. The averagepulse particle number of 36Ar18+ was about 5.4×106 in onestandard multiturn injection. With the help of electron cooling of partially hollow electron beam, 1.2×108

particles were accumulated in the ring after 29 timesinjection in 10 seconds, and 1.1×108 particles were accelerated to final energy of 1GeV/u. 3.8×108 particleswere stored for long time accumulation. The best resultswere demonstrated in Figure 4. Comparing with theresults in reference[2], accumulation rate which is definedas the increase of circulating current per unit of timedivided by the current in the injection line to thesynchrotron, was achieved 6 in the commissioning ofCSRm. It seems slightly better than the maximal value 5in the reference.

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 180

100

200

300

400

500

600

7000 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

0

100

200

300

400

500

600

700

ion

curr

ent

I 36Ar

18+ /

A

time / sec

36Ar18+ 21.7MeV/u---600MeV/uUgrid=0.3418kVUanode=1.6553kVIelectron=200mAfexp=3.3

Tinj=360ms

Figure 4: A complete cycle of accumulation andacceleration of 36Ar18+ with electron beam.

Multiturn jection of 129Xe27+

It should be mentioned that a new superconductingECR ion source SECRAL developed by IMP has startedoperation to provide high intensity heavier ion beam[3].129Xe27+ delivered by the SECRAL was accelerated bySFC to 2.9MeV/u and then injected into CSRm, theaverage pulse intensity was about 3.0μA in the injectionline. The average pulse particle number of 129Xe27+ wasabout 1.0×107 in one standard multiturn injection. Withthe help of electron cooling of partially hollow electron

beam, 1.2×108 particles were accumulated in the ring after 29 times injection in 10 seconds, and 1.0×108

particles were accelerated to final energy of 235GeV/u.1.1×108 particles were stored after long timeaccumulation.

1.626 1.628 1.630 1.632 1.634 1.636 1.6380

10

20

30

40

50

60

70

801.626 1.628 1.630 1.632 1.634 1.636 1.638

0

50

100

150

200

250

300

350

400

after 10sec accumulation

ion

curr

ent i

n 10

sec

I10

seco

nd /

A

Uhv / kV

129Xe27+

2.86---235MeV/u

Ugrid=0.1636kVUanode=0.8008kVIelectron=66mAfexp=3.3Tinj=350ms

after acceleration

ion

curr

ent a

fter a

ccel

erat

ion

I final /

A

Figure 5: 129Xe27+ intensity after accumulation andacceleration as a function of electron beam energy.

The ion intensity after 10s accumulation and acceleration depending on the electron beam energy wasinvestigated in case of fixed electron beam current andprofile, the results are illustrated in Figure 5. Theaccumulated intensity in 10s does not critically rely on theelectron energy compared with the intensity after acceleration. The reason was that the RF capturefrequency is more precise than the velocity of electrons. The same phenomena were observed in thecommissioning of 12C5+. The potential drop caused byspace charge of electron with different profile was takeninto account at the time of finely tuning the velocity of theelectron beam.

0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.10

10

20

30

40

50

60

70

80

90

1000.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1

0

50

100

150

200

250

300

350

400

450

500

Acc

umul

ated

ion

curr

ent i

n10

sI 12

9 Xe27

+ /

A

Ugrid/Uanode

Ielectron

=66mA Ielectron=96mA

129Xe27+ 2.86---235MeV/u fexp=3.3Tinj=350ms

ion

curre

ntaf

ter a

ccel

erat

ion

I 129 Xe

27+ /

A

Ielectron

=66mA Ielectron=96mA

Figure 6: 129Xe27+ intensity after 10 seconds accumulationand acceleration as a function of the ratio Ugrid/Uanode of electron gun.

In the interest of optimization the electron beam profilefor accumulation, the electron beam profile was changedat fixed electron beam current. The results were shown inFigure 6. One can see that at the larger ratio Ugrid/Uanode,the electron density in the centre of electron beambecomes smaller than that at the edge. The ion beam was

In

In

Proceedings of COOL 2007, Bad Kreuznach, Germany TUM1I02

61

Page 4: Commissioning of Electron Cooling in CSRmaccelconf.web.cern.ch/AccelConf/cl07/papers/tum1i02.pdfexcite the ion beam, a BPM was used to monitor the Schottky signal, the length of its

weakly cooled in this case, and the accumulated ion becomes smaller. When the electron beam currentincreases, the electron density in the centre slightlyincreases, and the accumulated ion beam also increase.Optimum accumulation happened when the ratio Ugrid/Uanode is near 0.2.Multiturn jection of 12C5+

In order to examine the performance of the elements for fast extraction, repeated multiturn injection was done with8.26MeV/u 12C5+ without stripping. The average pulseintensity was about 3μA in the injection line. The averagepulse particle number of 12C5+ was about 4.0×107 in onestandard multiturn injection, with the help of electron cooling of partially hollow electron beam, 3.5×108

particles were accumulated in the ring after 10 timesinjection in 10 seconds, and 4.6×108 particles were accelerated to final energy 100MeV/u. The lifetime of 16 seconds of 12C5+ is short compared with 255s of 12C6+,after longer time accumulation only 4.6×108 particleswere accumulated and saturation was reached.

Figure 7: Decrease of the stored 12C5+ intensity with timefor different profile electron beam at different current.

The charge state of ion 12

C5+

is medial, so that thepossibilities of ion loss due to various mechanisms existin the ring. In the absence of electron beam, the ionizationand electron capture process due to residual gasdetermines the lifetime of ion beam in the ring. In thepresence of electron beam, the electron capture processwill dominate. Figure 7 reveals the decrease of the stored12C5+ ion current during cooling at different electron current and profile. Figure 8 shows the lifetime of thestored 12C5+ ion with the ratio Ugrid/Uanode in electron gunat different electron current. It is clear that the lifetime islonger in the case of partially hollow electron beam. Theaccumulation efficiency demonstrated is higher for hollow electron beam in 10 seconds. In the case of biggercurrent of hollow electron beam, the lifetime becomesshorter, but accumulation becomes higher. Much higheraccumulation efficiency for higher ratio Ugrid/Uanode can beexplained by improving the vacuum conditions. Vacuumcondition along ring depends on the degasification byaction of ion beam and it will be improved with time.

The effect of the electron beam expansion factor on theaccumulation is shown in Figure 9. After repeated

multiturn injection, the emittance of ion beam will beclose to the transverse acceptance of the ring. And theradius of ion beam will be 3.8cm in the cooling section.The ion beam is completely surrounded by the electron. The accumulation is improved in the case of biggerexpansion factor. The experimental results don’t changesmoothly and regularly because of the fluctuation of injected ion beam.

-0.2 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.60

5

10

15

20

25

30

35

40

45-0.2 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6

0

10

20

30

40

50

60

70

80

90

lifet

ime

12C

5+ /

sec

Ugrid

/Uanode

solid 70mA

hollow 100mA

hollow 70mA

hollow 100mA

hollow 100mA

hollow 148mA

hollow 100mA

hollow 100mA

hollow 100mA

hollow 148mAhollow 70mA

solid 70mA

Red star---Max accumulated intensityBlack star---lifetime

12C5+

8.26MeV/u

Max

acc

umul

ated

inte

nsity

in 1

0s /

A

Figure 8: Lifetime of the stored 12C5+ ion as a function ofthe ratio Ugrid/Uanode of electron gun at different electron current.

2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.00

10

20

30

40

50

60

702.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0

0

20

40

60

80

100

120

140

10sec

ion

curre

ntin

10

sec

I 10se

cond

/ A

expansion factor

12C5+ 8.26MeV/u---100MeV/u

Ugrid=0.2856kVUanode=1.3721kVIelectron=150mABcooling section=375Gauss

after acceleration

ion

curr

ent a

fter a

ccel

erat

ion

I final /

A

Figure 9: 12C5+ intensity after 10 seconds accumulationand acceleration as a function of expansion factor.

The accumulation rate subjects to the cooling time and injection repetition rate. It is determined by the electronbeam parameters and injected ion beam stability.Variation of the time between two successive multiturninjections is illustrated in Figure 10. The optimum timeinterval between the two adjacent multiturn injectionscorresponds to the transverse cooling time of ion.

The influence of the electron beam current on theaccumulation is illustrated in Figure 11, The accumulatedion intensity in 10s was measured as a function of theelectron current for the different electron beam profile.For the hollow electron beam, because the electron density in the centre decreases, higher electron current is

In

TUM1I02 Proceedings of COOL 2007, Bad Kreuznach, Germany

62

Page 5: Commissioning of Electron Cooling in CSRmaccelconf.web.cern.ch/AccelConf/cl07/papers/tum1i02.pdfexcite the ion beam, a BPM was used to monitor the Schottky signal, the length of its

needed for the same cooling. The effects of higherelectron beam current on the work-point should be takeninto account.

0 250 500 750 1000 1250 15000

5

10

15

20

25

30

35

40

45

500 250 500 750 1000 1250 1500

0

5

10

15

20

25

30

35

40

45

50

Ielectron=76mA Ugrid/Uanode=0.2 Uhv=4.5285kV Ielectron=100mA Ugrid/Uanode=0.2 Uhv=4.5456kV Ielectron=150mA Ugrid/Uanode=0.2 Uhv=4.59kV Ielectron=200mA Ugrid/Uanode=0.2 Uhv=4.6275kV

I 12C

5+ /

A

Injection period Tinj

/ ms

12C5+ 8.26MeV/u

Figure 10: 12C5+ intensity after 10 seconds accumulationas a function of the time interval between subsequentmultiturn injections at different electron current in case ofthe same electron beam profile.

25 50 75 100 125 150 1750

10

20

30

40

50

60

70

80

90

10025 50 75 100 125 150 175

0

10

20

30

40

50

60

70

80

90

100

I 10se

cond

/ A

electron beam current / mA

Ugrid/Uanode=0

Ugrid/Uanode=0.2

Ugrid/Uanode=0.5

Ugrid/Uanode=1.0

Ugrid/Uanode=1.5

12C5+ 8.26MeV/u Tinj=0.9sfexp=3.3

Figure 11: 12C5+ intensity after 10 seconds accumulationas a function of the electron current at different ratiobetween Ugrid and Uanode of electron gun.

The impact of the electron beam profile on theaccumulation is shown in Figure 12. The accumulated ionintensity in 10s was measured as a function of the ratioUgrid /Uanode of electron gun at different electron current. Itis clear that optimum accumulation happened in thepartially hollow electron beam, the ratio Ugrid /Uanode isclose to 0.2. In this case, the central density is 2 times lessthan the edge one in the electron beam.

Table 2: Accumulation parameters of ion beamIon Einj M Iinj

μAFoil

μg/cm2Tinj

msLifetime

secIe

mA12C6+ 7.09 ST 12 15 1000 255 7012C4+ 7.1 MI 6 1000 27.7 124

36Ar18+ 21.7 MI 4 350 350 554.7 97129Xe27+ 2.9 MI 3 350 12 70

12C5+ 8.26 MI 3 900 16 151

The injection parameters of ion are enumerated in table2, Iinj is the intensity of single multiturn shot, Tinj is the

injection period, and the lifetime of the ion beams with the electron beam is listed in the penultimate column.

The momentum spread of the ion beams aresummarized in table 3, after accumulation andacceleration it is in the range of 10-4.

-0.2 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.60

10

20

30

40

50

60

70

80

90

100-0.2 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6

0

10

20

30

40

50

60

70

80

90

100

I 10se

cond

/ A

Ugrid/Uanode

Ielectron

=50mA I

electron=70mA

Ielectron

=100mA I

electron=150mA

12C5+ 8.26MeV/u

Figure 12: 12C5+ intensity after 10 seconds accumulationas a function of the ratio Ugrid /Uanode of electron gun at different electron current.

Table 3: Momentum spread of ion beam

Ion Eion Mode P/Pinj P/P10sec P/Pfinal

12C6+ 7.09---1000 ST 1.46×10-3 3.9×10-3 3.6×10-4

36Ar18+ 21.7---1000 MI 6.98×10-4 3.2×10-4 2.5×10-4

129Xe27+ 2.9---235 MI 2.4×10-4 1.8×10-4

12C5+ 8.26---100 MI 2.3×10-4 1.3×10-4

SUMMARY AND OUTLOOKExperimental results indicate that the partially hollow

electron beam has an advantage in beam accumulation.The optimal ratio Ugrid/Uanode is near 0.2. In this case, thecentre density is 2 times less than the edge density in theelectron beam. The equilibrium momentum spreadincreases with the number of accumulated ions; the resultis unanimous contrasted with the SIS cooler. The optimalelectron currents are well agreed with simulated one withthe help of Vasily’s electron cooling simulation code.Systematic investigation of cooling with hollow electron beam will be performed in the future.

REFERENCES[1] J.W. Xia et al, “Construction and Commissioning of

the HIRFL-CSR”, APAC’2007, Indore, India,January 2007

[2] M. Steck et al, “Beam Accumulation with the SIS Electron Cooler”, NIM A441(2000) 175-182.

[3] H. W. Zhao et al, “First Results of SECRAL at 18GHz for Intense Beam Production Highly ChargedIons”, HEPNP Vol (31) S1 (2007)8-12.

Proceedings of COOL 2007, Bad Kreuznach, Germany TUM1I02

63