Page 1: Comfort - geoservices.ca · mor-09hdn1-bn10w mor-12hdn1-bn10w moc-18hdn1-mn10w mof-22hdn1-mn10w 115v 1ph/60hz 115v 1ph/60hz 208-230v 1ph/60hz 208-230v 1ph/60hz 15 15 20 25 56 57

INVERTER

Comfortat it’s best!

DUCTLESS AIR CONDITIONING OR HEAT PUMP SYSTEM

Page 2: Comfort - geoservices.ca · mor-09hdn1-bn10w mor-12hdn1-bn10w moc-18hdn1-mn10w mof-22hdn1-mn10w 115v 1ph/60hz 115v 1ph/60hz 208-230v 1ph/60hz 208-230v 1ph/60hz 15 15 20 25 56 57

DUCTLESS AIR CONDITIONERS AND HEAT PUMPS

INVERTER

Compact and quiet outdoor unit

• Easy-to-use infra-red remote control unit

• Quiet, three-speed fans

• Louver position memory function

• Auto pivot air sweep

• Reusable, washable filters for quick and easy maintenance

• Anti-cycling protection for compressor

• R410A refrigerant meets industry standards and protects environment

• Digital display on unit ensures optimal operation

• Compact indoor unit of only 26.75 in. for 9,000 Btu/h

• PTC Heat cable prevents ice from accumulating in outdoor unit

Comfort-relatedfeatures:

Remote CONTROL UNIT

The unit can be installed high on the wall, while allowing user to enjoy full remote control. Louvers permit excellent air circulation, even in confined locations.

MODE : Auto – Cool – *Heat Dry – Fan. Cycles through the diffrent modes at each press of the button.

SWING : Adjusts the angle of the louvers to direct the air wheer you want it.

AIR DIRECTION : Sets the direction of blown air

FAN SPEED : Chooses the fan speed in 4 steps; Auto, Low, Medium, High.

TIMER ON : Sets the start time of the AC in increments of 30 minutes.

TIMER OFF : Sets the stop time of the AC in increments of 30 minutes.

TURBO : Allows the fan to operate at high speed to reach the set temperature faster.

LED DISPLAY : Allows to display or not the information in the display window.

SLEEP MODE:Adjusts the temperature and maintains it for 5 hours before shutting down

Mode Selection : Auto – Cool – *Heat

Dry - Fan

Louver direction setting

Louver direction setting

Fan speed selection

Start time selection

Stop time selection

Turbo mode

LED Display mode

Model MS11DContemporary indoor unit

MEMORIZED LOUVER POSITION

OAIR CONDITIONER COOLS UP TO 0 COHEAT PUMP HEATS UP TO -15 C

REFRIGERANT LEAK DETECTION

* Heat Pump Only

Page 3: Comfort - geoservices.ca · mor-09hdn1-bn10w mor-12hdn1-bn10w moc-18hdn1-mn10w mof-22hdn1-mn10w 115v 1ph/60hz 115v 1ph/60hz 208-230v 1ph/60hz 208-230v 1ph/60hz 15 15 20 25 56 57

- Turbo Mode: This function will heat or cool a room to the desired temperature more rapidly.

- Cold Catalyst Filter: Eliminates VOCs (Volatile Organic Compounds) and other harmful gases as well as odors.

- Bidirectional Ventilation: In cooling mode, the cold air will be blowing horizontally while in heat mode, the warm air will be directed vertically. This technology makes the room temperature more comfortable and consistent.

- PTC Heat Strap: The PTC heat strap prevents the accumulation of snow and ice at the base of the outdoor unit.

- Low Ambient Kit: The air conditioner equipped with the low ambient kit can be used even if the outdoor temperature is as low as -0°C.

- Energy saving Protection: When the outdoor temperature reaches -15°C, the unit will turn off by itself to save energy.

- Sleep Mode: This function enables the air conditioner to automatically increase or reduce the temperature by 1°C every hour for 2 hours and hold steady for the next 5 hours before shutting down.

- Auto-restart: If the unit shuts down unexpectedly due to power outage, it will restart with the previous function setting automatically when the power returns.

- Refrigerant Leakage Detect: Indoor unit will display error code EC and automatically stop when refrigerant leakage is detected to protect compressor from overheating.

EACH DIRECT AIR

MINI-SPLIT HEAT PUMP SYSTEM COMES WITH THESE STANDARD FEATURES:

Page 4: Comfort - geoservices.ca · mor-09hdn1-bn10w mor-12hdn1-bn10w moc-18hdn1-mn10w mof-22hdn1-mn10w 115v 1ph/60hz 115v 1ph/60hz 208-230v 1ph/60hz 208-230v 1ph/60hz 15 15 20 25 56 57

5yearson compressoron compressoron compressor 5years

on partson partson parts

- Easy installation

- Attractive

- Only 3” wall

opening integrates

seamlessly

into existing decor

- Ideal for condos

5yearson compressoron compressoron compressor 5years

on partson partson parts

5yearson laboron laboron labor

Limited

Warranty

Comfort like you like it

Limited

Warranty

Page 5: Comfort - geoservices.ca · mor-09hdn1-bn10w mor-12hdn1-bn10w moc-18hdn1-mn10w mof-22hdn1-mn10w 115v 1ph/60hz 115v 1ph/60hz 208-230v 1ph/60hz 208-230v 1ph/60hz 15 15 20 25 56 57

SPECIFICATIONS AIR CONDITIONERS

Model

Cooling Capacity (Btu/h)

SEER

Humidity Removal (L/h)

Air Flow H-M-L (CFM)

Noise H-M-L (Db)

Width (mm/in)

Height (mm/in)

Depth (mm/in)

Weight (Kg/lb)

Outdoor Unit

Voltage

Breaker Amp

Noise (Db)

Width (mm/in)

Height (mm/in)

Depth (mm/in)

Weight (Kg/lbs)

MS11D-09CRDN1-BN10W MS11D-12CRDN1-BN10W MS11D-18CRDN1-MN10W MS11D-22CRDN1-MN10W

2 250 / 9 900 2 600 / 13 200 5 300 / 20 000 6 500 / 24 200

15,0 15,0 15,0 15,0

1,0 1,2 1,8 2,4

282/247/188 341/294/ 236 441/388/282 736/677/559

39/35/28 39/35/29 42/39/31 47/45/39

680 / 26,75 770 / 30,31 905 / 35,63 1030 / 40,55

255 / 10,04 255 / 10,4 275 / 10,83 315 / 12,40

178 / 7,01 188 / 7,40 198 / 7,8 218 / 8,58

7 / 15,4 7,5 / 16,5 9 / 19,8 12 / 26,4

MOR-09CDN1-BN10W MOR-12CDN1-BN10W MOC-18CDN1-MN10W MOF-22CDN1-MN10W

115V/1Ph/60HZ 115V/1Ph/60HZ 208-230V/1Ph/60HZ 208-230V/1Ph/60HZ

20A 20A 15A 20A

54 55 59 59

660 / 26 660 / 26 760 / 29,92 845 / 33,27

540 / 21,3 540 / 21,3 590 / 23,23 700 / 27,56

265 / 10,4 265 / 10,4 285 / 11,22 320 / 12,6

27 / 59,4 28 / 61,6 35 / 77 45 / 99

SPECIFICATIONS HEAT PUMPS

Model

Cooling Capacity Min/Max (Btu/h)

Heating Capacity Min/Max (Btu/h)

SEER

EER

HSPF Region 4

HSPF Region 5 Canada

Humidity Removal (L/h)

Indoor Unit

Air Flow H-M-L (CFM)

Noise H-M-L (Db)

Width(mm/in)

Height(mm/in)

Depth(mm/in)

Weight (Kg/lbs)

Outdoor Unit Model

Voltage

Breaker Amp

Noise (Db)

Width(mm/in)

Height(mm/in)

Depth(mm/in)

Weight (Kg/lbs)

MS11D-09HRDN1-BN10W MS11D-12HRDN1-BN10W MS11D-18HRDN1-MN10W MS11D-22HRDN1-MN10W

2 250 / 9 900 2 600 / 13 200 5 300 / 20 000 6 500 / 24 200

2 300 / 11 000 2 800 / 13 000 5 500 / 23 000 6 500 / 26 000

15,0 15,0 15,0 15,0

9,0 9,0 9,0 9,0

8,2 8,2 8,2 8,2

7,2 7,2 7,2 7,2

1,0 1,2 1,8 2,5

295 / 242 / 212 354 / 313 / 236 443 / 389 / 283 738 / 679 / 561

38/31/29 39/35/31 42/39/31 49/45/39

680 / 26.75 770 / 30.3 905 / 35.6 1 030 / 40.55

255 / 10.0 255 / 10.0 275 / 10.8 315 / 12.4

178 / 7.0 188 / 7.4 198 / 7.8 218 / 8.6

7 / 15 7,5 / 16,5 9 / 20 12 / 26,5

MOR-09HDN1-BN10W MOR-12HDN1-BN10W MOC-18HDN1-MN10W MOF-22HDN1-MN10W

115V 1Ph/60HZ 115V 1Ph/60HZ 208-230V 1Ph/60HZ 208-230V 1Ph/60HZ

15 15 20 25

56 57 59 60

660 / 26 660 / 26 760 / 30.0 845 / 33.25

540 / 21.25 540 / 21.25 590 / 23.25 700 / 27.55

265 / 10.4 265 / 10.4 285 / 11.25 320 / 12.6

27 / 59 30 / 66 37,5 / 83 47 / 103

Page 6: Comfort - geoservices.ca · mor-09hdn1-bn10w mor-12hdn1-bn10w moc-18hdn1-mn10w mof-22hdn1-mn10w 115v 1ph/60hz 115v 1ph/60hz 208-230v 1ph/60hz 208-230v 1ph/60hz 15 15 20 25 56 57

Retailer

Directairhvac.com

To find your nearest Direct Air dealer, please contact the Powrmatic branch of your area.

Montréal9500, boul. Ray-LawsonAnjou, Qc, H1J 1L1Tel.: 514.493.6400Fax: [email protected]

Québec385, FortinVille-Vanier, Qc, G1M 1B2Tel.: 418.683.2708Fax: [email protected]

Ottawa162, Elm StreetOttawa, On, K1R 6N5Tel.: 613.230.7160Fax: [email protected]

Toronto111; Staffern DriveConcord, On, L4K 2R2Tel.: 905.660.0033Fax: [email protected]

London1064, Hargrieve RoadLondon, On, N6E 1P5Tel.: 519.675.1491Fax: [email protected]

Halifax100, Wright Ave.Dartmouth, NS, B3B 1L2Tel.: 902.454.8684Fax: 902:[email protected]

326ANG-0314

WARRANTYWARRANTYWARRANTY

LIMITEDLIMITEDLIMITED

THE MS11D SERIES OF AIR CONDITIONERS

have a 5 year limited warranty on the compressor and 5 years on parts

THE MS11D SERIES OF HEAT PUMPS

have a 5 year limited warranty on the compressor, 5 years on parts and 5 years on labour

DIRECTAIRHVAC.COM