combustible gas leak detector - marks supply · 2020-04-25 · combustible gas leak detector the...

20
Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible gases including Methane (Natural Gas), Propane, Butane, Ethane (R170), Acetylene, Methanol, Acetone and Gasoline. MSHA Certified as Intrinsically Safe. Inspect furnaces, gas appliances and gas lines fast and safely. Also use to find leaks in fuel and exhaust systems plus verify integrity of fuel storage containers. The unique digital display allows for quick, precise pinpointing of the leak source and also determines the size of the leak. Housed in rugged high impact ABS plastic. Part # 53-D-540 Description Leak Detector; Combustible Gas Sensitivity <10 ppm (methane) Sensor Life >300 hours Response Time Instantaneous Power Supply 4 AA Alkaline batteries (included) Battery Life 20 hours continuous Warm Up Time <10 seconds Probe Length 43cm (17”) Numerical Display 1 to 9 Weight 0.58kg (1.5lbs) Warranty 2 years (includes sensor) SPECIFICATIONS FEATURES Long life, stable sensor Unique numeric leak size indicator & alarm Automatic calibration and reset to ambient levels 3 adjustable sensitivity levels Low battery indicator Audio mute function Comfortable sanoprene grip MSHA Intrinsic Safety Certified CE Certified Made in USA 2 Year Warranty (includes sensor) Detectable Gases (Partial List) Methane, Propane, Ethane, Butane, Hydrogen, Ethylene, ISO-Butane, NOL, Gasoline, Acetylene, Ammonia, H. Sulfide, Industrial Solvents, Alcohol, Acetane, Foluene, Xylene. 53-D-540 Storage case included RED HOT PRICING! ORDER NOW!

Upload: others

Post on 12-Jul-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Combustible Gas Leak Detector - MARKS SUPPLY · 2020-04-25 · Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible

Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible gases including Methane (Natural Gas), Propane, Butane, Ethane (R170), Acetylene, Methanol, Acetone and Gasoline. MSHA Certified as Intrinsically Safe. Inspect furnaces, gas appliances and gas lines fast and safely. Also use to find leaks in fuel and exhaust systems plus verify integrity of fuel storage containers. The unique digital display allows for quick, precise pinpointing of the leak source and also determines the size of the leak. Housed in rugged high impact ABS plastic.

Part # 53-D-540Description Leak Detector; Combustible GasSensitivity <10 ppm (methane) Sensor Life >300 hoursResponse Time InstantaneousPower Supply 4 AA Alkaline batteries (included)Battery Life 20 hours continuousWarm Up Time <10 secondsProbe Length 43cm (17”)Numerical Display 1 to 9Weight 0.58kg (1.5lbs)Warranty 2 years (includes sensor)

SPECIFICATIONS

FEATURES • Long life, stable sensor• Unique numeric leak size

indicator & alarm• Automatic calibration and reset

to ambient levels• 3 adjustable sensitivity levels• Low battery indicator• Audio mute function• Comfortable sanoprene grip• MSHA Intrinsic Safety Certified• CE Certified• Made in USA• 2 Year Warranty (includes sensor)

Detectable Gases (Partial List)Methane, Propane, Ethane,Butane, Hydrogen, Ethylene, ISO-Butane, NOL, Gasoline,Acetylene, Ammonia, H. Sulfide,Industrial Solvents, Alcohol,Acetane, Foluene, Xylene.

53-D-540

Storage case included

RED HOTPRICING!

ORDER NOW!

Page 2: Combustible Gas Leak Detector - MARKS SUPPLY · 2020-04-25 · Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible

alltemp heating special 08/092

2008/09 Heating Specialwww.alltemp.ca

Heat SequencersFeatures

• Solid State PTC Heaters• Quick-Connect Terminals• Shock & Vibration Resistant• Mounts in any position• Contact Ratings - to 25 Amps at 120 or 240 Volts, and 12.5A at 480 Volts• Full-Load Rated Auxilliary Contacts• Standard Operating Ambience Between -50°F (-45.5°C) and 165°F (73.8°C)

Notes• M1-M2 and M3-M4 are always the first switches to turn on and the last to turn off. All other switches are random on and random off.• ON TIME - Elapsed time to make contacts after heater is energized• OFF TIME - Elapsed time to make contacts after heater is de-energized• OFF timings determined after PTC heater has been electrified for a total of 5 minutes• Standard Timings determined at 25°C. Timings at temperatures above or below 25° will vary

Combined Load Ratings (all models): 30A @ 240 VAC - Total: 23 A non-inductive + 7 FLA/42 LRA Inductive Life at rated current: 100,000 cycles

Heater Pole24 Vac 0.18A (anticipator)0.75A Max Inrush0.16 to 0.20 amps Steady StateAmbient Rating: - 50° to 160°F

Applications• Electric Furnaces• Baseboard Heaters• Duct Heaters• Suspension Heaters• Recreational vehicle blower and element control• Heat pump blower and heating element control• Motor speed switching in air conditioning ( high speed ) / heating systems (low speed) where a single set of contacts handle combination motor and heater element loading in the heater function• Control circuts requiring definate sequence on both start up and shut downStandard Timings

Electrical Ratings

Part # Timings Switches Timings (seconds) - On Timings (seconds) - Off

M1- M2

M3- M4

M5- M6

M7- M8

M9- M10

M1- M2

M3-M4

M5-M6

M7-M8

M9-M10

HS-24A34-21 1 1 1-20 1-60

HS-24A34-22 1 1 15-45 1-30

HS-24A34-23 1 1 25-60 15-45

HS-24A34-24 1 1 30-90 1-40

HS-24A34-25 1 1 30-90 1-30

HS-24A34-26 2 2 1-20 30-90 40-90 1-30

HS-24A34-27 3 1 1-160 1-160

HS-24A34-29 1 1 15-35 25-55

HS-24A34-36 2 2 1-20 30-90 45-110 1-30

HS-24A34-37 3 1 1-110 1-110

VACResistive (non-inductive) Motor ratings (inductive) Pilot

DutyWatts Amps Full Load Locked Rotor

120 3000 25.0 10.0A 60.0A 125VA

240 6000 25.0 5.0A 30.0A 125VA

480 6000 12.5 3.0A 18.0A 480VA

NEW!

HS-24A34-21, 22, 23, 24, 25 HS-24A34-29 HS-24A34-26, 27, 36 HS-24A34-37

Page 3: Combustible Gas Leak Detector - MARKS SUPPLY · 2020-04-25 · Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible

alltemp heating special 08/09 3

2008/09 Heating Specialwww.alltemp.ca

One Pole Contactors• One pole contactor with shunt • UL, CSA, CE Approved• 4 - 1/4" Brass Spade Terminals Per Power Connection• #10-32 Combination Screw Terminals• 50/ 60 Hz

Part #Full Load

Amps.Coil Voltage

50/60Resistive

Amps.Locked Rotor Amps.@240V

Height Width Depth

HC-13024 30 24 40 150 2.39" 2.00" 3.29"HC-130120 30 120 40 150 2.39" 2.00" 3.29"HC-130240 30 208/240 40 150 2.39" 2.00" 3.29"

Two Pole Contactors• UL, CSA, CE Approved• 30 Amp.= 4 - 1/4" Brass Spade Terminals Per Power Connection• 40 Amp.= 4 - 1/4" Copper Spade Terminals Per Power Connection• 50/ 60 Hz• Contact Cover Over Contacts (40 Amp Models & Up)

Part #Full Load

Amps.Coil Voltage

50/60Resistive

Amps.Locked Rotor Amps.@240V

Height Width Depth

HC-23024 30 24 40 150 2.45" 2.00" 3.29"HC-230120 30 120 40 150 2.45" 2.00" 3.29"HC-230240 30 208/240 40 150 2.45" 2.00" 3.29"

HC-24024 40 24 50 200 2.63" 2.00" 3.29"HC-240120 40 120 50 200 2.63" 2.00" 3.29"HC-240240 40 208/240 50 200 2.63" 2.00" 3.29"

HC-130241 Pole Contactor With Shunt Illustrated

HC-230242 Pole Contactor Illustrated

Definite Purpose Magnetic Contactors

Contactor Terminal Types• 30 Amp. = #10-32 Combination Screw

Terminals.• 40 Amp. = # 14-4 Aluminum Compression Lug

Terminals With 1/4"-20 Screws.• 50 - 60 Amp. = # 14-2 Aluminum Compression

Lug Terminals With 1/4"-20 Screws.• 75 - 90 Amp. = # 14-1 Aluminum Compression

Lug Terminals With 1/4"-20 Screws.Custom Terminal Type Models Available

Upon Request!

Rotom Definite Purpose Magnetic ContactorsContactors are designed to establish or interrupt a power circuit. Definite purpose contactors unlike general purpose contactors are non-rebuildable electronic controls designed for specific application with clearly defined operating condi-tions.

Auxiliary Switch.HC-600

Auxiliary Switch.HC-250 (One Switch)

HC-500 (Two Switches)

Auxiliary Contact Switches• Clips Directly Onto Either End Of Any Rotom Contactor• 1/4" Quick Connect Terminals• Snap Fast Action Switch• UL & CSA Approved When Used With UL & CSA Approved Rotom Contactors

Part #Contactor

FLAContinuous

Amps.Voltage Rating

Description Height Width Depth

HC-250 30 & 40 10 300 1 × SPDT, N.O. & N.C. 2.81" 2.61" 0.67"HC-500 30 & 40 10 300 2 × SPDT, N.O. & N.C. 2.81" 2.61" 0.67"

HC-600* 30 & 40 10 6002 Contacts × 1 Pole, N.O

(make) or N.C. (break)2.77" 3.13" 0.70"

HC-300 50 & 60 10 300 1 × SPDT, N.O. & N.C. 2.00" 1.34" 0.79"* 6-32 Screw Terminal Model Available - Order Part # HC-600S

Auxiliary Switch.HC-300

FEATURES:• Compact size.• Quieter than traditional designs.• Far more efficient operation.• Universal electrical connections.• Quick connect terminals.• Universal galvanized mounting plates.• Protective contact cover.

• Snap on auxiliary contacts.• Individually labelled & packaged.• Easy to understand part numbers.• Complete cross reference.• cURus, UL, CSA & CE approved.• Price competitive.

Page 4: Combustible Gas Leak Detector - MARKS SUPPLY · 2020-04-25 · Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible

alltemp heating special 08/094

2008/09 Heating Specialwww.alltemp.ca

Three Pole Contactors• UL, CSA, (CE 30 - 60 Amp)• 30 Amp.= 2 - 1/4" Brass Spade Terminals Per Power Connection• 40 Amp.= 2 - 1/4" Copper Spade Terminals Per Power Connection• 50 - 90 Amp.= 2 - 1/4" Copper Spade Terminals & Aluminum Lug Per Power

Connection• 50/ 60 Hz• Contact Cover Over Contacts (30 - 40 Amp Feature Built-In Test Button)

Part #Full Load

Amps.Coil Voltage

50/60Resistive

Amps.Locked Rotor Amps.@240V

Height Width Depth

HC-33024 30 24 40 180 2.99" 2.37" 3.75"HC-330120 30 120 40 180 2.99" 2.37" 3.75"HC-330240 30 208/240 40 180 2.99" 2.37" 3.75"

HC-34024 40 24 50 240 2.99" 2.37" 3.75"HC-340120 40 120 50 240 2.99" 2.37" 3.75"HC-340240 40 208/240 50 240 2.99" 2.37" 3.75"

HC-35024 50 24 65 300 3.62" 2.75" 4.00"HC-350120 50 120 65 300 3.62" 2.75" 4.00"HC-350240 50 208/240 65 300 3.62" 2.75" 4.00"

HC-36024 60 24 75 360 3.62" 2.75" 4.00"HC-360120 60 120 75 360 3.62" 2.75" 4.00"

HC-360240 60 208/240 75 360 3.62" 2.75" 4.00"

HC-37524 75 24 90 450 4.05" 3.75" 5.18"

HC-375120 75 120 90 450 4.05" 3.75" 5.18"

HC-375240 75 208/240 90 450 4.05" 3.75" 5.18"

HC-39024 90 24 120 540 4.05" 3.75" 5.18"

HC-390120 90 120 120 540 4.05" 3.75" 5.18"

HC-390240 90 208/240 120 540 4.05" 3.75" 5.18"

Four Pole Contactors• UL, CSA, CE Approved• 30 Amp.= 2 - 1/4" Brass Spade Terminals Per Power Connection• 40 Amp.= 2 - 1/4" Copper Spade Terminals Per Power Connection• 50/ 60 Hz• Contact Cover Over Contacts With Built-In Test Button

Part #Full Load

Amps.Coil Voltage

50/60Resistive

Amps.Locked Rotor Amps.@240V

Height Width Depth

HC-43024 30 24 40 180 2.99" 2.75" 3.75"

HC-430120 30 120 40 180 2.99" 2.75" 3.75"

HC-430240 30 208/240 40 180 2.99" 2.75" 3.75"

HC-44024 40 24 50 240 2.99" 2.75" 3.75"

HC-440120 40 120 50 240 2.99" 2.75" 3.75"

HC-440240 40 208/240 50 240 2.99" 2.75" 3.75"

Contactor NomenclatureHC - 1 30 24

HC = Product Code1 = Poles (1, 2, 3 or 4)30 = Full Load Amps. (30A, 40A...)24 = Coil Voltage (24, 120 or 240)

Typical Applications• Heating• Ventilation• Air Conditioning• Refrigeration

- Compressors- Motors

• Agriculture • Pool & Spa Controls• Food Service Equipment• Welding Equipment• Business Machines

HC-330243 Pole, 30-40 Amp

Illustrated

HC-440244 Pole Contactor Illustrated

Definite Purpose Magnetic Contactors

HC-3601203 Pole, 50-90 Amp

Illustrated

Page 5: Combustible Gas Leak Detector - MARKS SUPPLY · 2020-04-25 · Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible

alltemp heating special 08/09 5

2008/09 Heating Specialwww.alltemp.ca

Totally Enclosed Fan Relays - Heavy Duty

General Purpose Fan Relays - Standard DutyFeatures Designed for switching single or two speed fan motor, relays,

solenoids, resistive loads in cooling, heating or general pur-pose switching applications.

• Replace WR/ Essex/ RBM & Mars type 84 models• Totally enclosed compact design.• Quiet & reliable operations.• UL & cUR (file E44211)• Universal mounting bracket.

Features Designed for cooling, heating or general purpose switching

equipment operating heavier loads.• Replace WR/ Essex/ RBM & Mars type 184 models• Totally enclosed compact design.• Quiet & reliable operations.• Universal mounting bracket• UL & cUR (file E44211)• SPST, SPDT & SPNO/SPNC models.

Specifications• Temperature Range: -20°C (-4°F) to 40°C (104°F).• Mechanical Life: 1,000,000 operations.• Electrical Life: 100,000 operations (@ 25amp 277VAC Res.)• Operate Time (typical): 25 ms at nominal coil voltage.• Release Time (typical): 25 ms at nominal coil voltage.• Dielectric Strength (at sea level for 1 min.):- 2500 Vrms coil to contact.- 1000 Vrms between open contacts.• Coil Frequency: 50/60 Hz.• Coil Insulation: Class A (105°C / 221°F).• Coil Duty Cycle: Continuous.• Terminals: ¼" quick-connects.• Contact Material: Silver cadmium oxide.• Enclosure: Phenolic.

Specifications• Temperature Range: -20°C (-4°F) to 40°C (104°F).• Mechanical Life: 1,000,000 operations.• Electrical Life: 100,000 operations (@ 16amp 240VAC Res.)• Operate Time (typical): 25 ms at nominal coil voltage.• Release Time (typical): 25 ms at nominal coil voltage.• Dielectric Strength (at sea level for 1 min.):- 2500 Vrms coil to contact.- 1000 Vrms between open contacts.• Coil Frequency: 50/60 Hz.• Coil Insulation: Class A (105°C / 221°F).• Coil Duty Cycle: Continuous.• Terminals: ¼" quick-connects.• Contact Material: Silver cerium• Enclosure: Phenolic.

Totally Enclosed Relay - 2 Pole HVAC Switching Relays

Heavy Duty Relays

Coil Voltage

DPDTPart #

Terminals 1,2,3.

Terminals 4,5,6.

Resistance DC OHMS

±10%

Nominal Current

MA

Nominal VA

Sealed Max.

Inrush VA

Max.

Cross Reference

WR/RBM

Honeywell Mars

24 25-90340Power Power

15 334

8 21.5

90-340 R4222B1082 90340

120 25-90341 400 66 90-341 R4222B1090 90341

240 25-90342 1415 38 90-342 R4222D1013 90342

Features Intended for many applications in air conditioning, refrigeration,

heating and general purpose switching.• Replaces Honeywell, White-Rodgers/RBM & Mars (cross refer-

ence in packaging)• Semi-enclosed compact design.• Quiet & reliable operations.• Universal mounting bracket• Molded terminal numbers and circuit diagram on top of relay.• UL & cUR (file E44211).• 2 Pole DT mode

Specifications• Temperature Range: -40°C (-40°F) to 54°C (130°F).• Mechanical Life: 750,000 operations.• Electrical Life: 100,000 operations.• Coil Frequency: 50/60 Hz.• Coil Insulation: Class B.• Coil Duty Cycle: Continuous.• Terminals: ¼" quick-connects.• Contact Material: Silver cadmium oxide.• Enclosure: Phenolic.• Dimensions 2.13" × 1.88" × 2.25".

25-90340Illustrated

25-90380Illustrated

25-90290Illustrated

Contact Rating- 125/250 VAC

FLA LRAInductive

AmpsResistive

Amps

8 188 Amp

Continuous16 Amp

Continuous

Heavy Duty Relays Coil

VoltageSPSTPart #

SPDTPart #

SPNO-SPNC*Part #

Coil Resistance DC OHMS

±10%

Nominal Current

MA

Nominal VA

Sealed

Inrush VA

24 25-90360 25-90370 25-90380 77 167

4 4120 25-90362 25-90372 25-90382 2,000 33

240 25-90364 25-90374 25-90384 7,200 17

*Isolated Contacts

Contact Rating

VAC Amps FLA LRAInductive

AmpsResistive

Amps

125VAC

25

14 84 14 Amp Continuous25 Amp

Continuous@ 277 VAC

250VAC 8 48 8 Amp Continuous

277VAC 7 42 7 Amp Continuous

Contact Rating

VACAmps

General Use

HP LRA FLA

125V

153/4

82.8 13.8208V 45.6 7.6250V 41.4 6.9277V - 36.0 6.0

Single Pole HVAC Standard Duty RelaysCoil

VoltagePart #SPST

Part #SPDT

Coil Resistance DC OHMS

±10%

NominalCurrent

MA

NominalVA

Sealed

Inrush VA

24 25-90290 25-90293 90 146

3.5 4120 25-90291 25-90294 2,000 29

240 25-90292 25-90295 7,200 15

Page 6: Combustible Gas Leak Detector - MARKS SUPPLY · 2020-04-25 · Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible

alltemp heating special 08/096

2008/09 Heating Specialwww.alltemp.ca

SPECIALLY DESIGNED FOR LOW VOLTAGE CONTROL APPLICATIONS IN THE INDUSTRIAL HEATING & COOLING INDUSTRY!

Features• Compact superior design.• Individually boxed with instructions.• Includes necessary mounting hardware.• Complete cross-reference.

Control TransformersControl Transformers

Control transformers are designed for use in 2.5, 12 or 24 volt al-ternating current (AC) control systems, including air conditioning circuits, thermostats, gas valves, relays and or other applications that do not exceed the listed ratings. These transformers can be used to replace any transformers of the same primary voltage and equal or smaller VA ratings.

25-52C6Mounting Plate

& Hardware

Foot Mount

Part # VA Primary VoltageSecondary

Voltage Connections34-20241 20 120 24 Wire34-40244 40 120 24 Wire34-40245 40 120/ 208/ 240 24 Wire34-40240W 40 240 24 Wire34-50254 50 575 24 QC

Multi Mount (Foot, Plate, Conduit)• 34-52C6 mounting plate, (2) screws & (2) wire connec-

tors included.

Part # VA Primary VoltageSecondary

Voltage Connections34-40241 40 120 24 Screw34-40242 40 208/ 240 / 277 24 Screw34-40243 40 120/ 208/ 240 24 Screw34-48003 48 120/ 208/ 240 2.5 / 12 / 24 Wire34-50243 50 120/ 208/ 240 24 Wire

Foot MountHeavy Duty (c/w Circuit Breaker)

Part # VA Primary VoltageSecondary

Voltage Connections34-75241 75 120 24 Wire34-75244 75 120/ 208/ 240/ 480 24 Wire34-10244 96 120/ 240/ 277/ 480 24 Wire

34-20241

34-4024434-40245 Illustrated

25-7524125-75244 Illustrated25-10244

25-FA112Optional

Mounting Plate

34-40240W Illustrated

25-40241 Illustrated25-40242 (4-wire)25-40243 25-48003 Illustrated

25-50243

NEW!

Page 7: Combustible Gas Leak Detector - MARKS SUPPLY · 2020-04-25 · Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible

alltemp heating special 08/09 7

2008/09 Heating Specialwww.alltemp.ca

Features• 30A and 50A switching capabilities• .250" quick connect termination• Safety timer• Approvals: UL, CSA, cUL pending• Single, wire-for-wire replacement for ALL standard potential relays; save thousands on inventory management costs while making sure you have the

right part on hand at all times! • Patented differential voltage sensing eliminates the

need to set dials or make other field adjustments; automatically senses correct voltage needed to ensure a precision start every time - regardless of motor wear! • Enhanced, patent-pending circuitry protects the

compressor by safely and intelligently discharging stray D.C. voltage from the start cap to prevent welding of contacts.

• Non-positional mounting configuration and universal mounting bracket simplify installation.

• American-made quality and reliability! • Ideal for A/C, commercial refrigeration, heat pump, or

any single-phase motor application up to 10HP.

Enhanced Series UMSRe

SpecificationsInput:• Voltage Rating: 110-270 VAC, Single Phase• Maximum Voltage Contact Rating: 502 VAC (absolute)• Motor Power Rating: Up to 10 HP• Operating Position: Non-positional• Safety Time Out: Approximately 1-second per microfarad• Consumption: 5VA max.• Insulation: Class B (130°C); Conforms to IEC 1000- standards (6kV impulse / 6kV contact)• Life Expectancy (minimum operations) Mechanical: 1 x 106

Electrical: 1 x 106 at 16A 400VAC• 5 x 105 at 35A 400VAC (break only)• 5 x 105 at 50A 400VAC (break only)Contacts:• Contact Rating: 30A (break only), 400 VAC cos Ø = 0.7 to 0.8 50A (break only), 400 VAC cos Ø = 0.7 to 0.8

ICM’s new Universal Motor Starting Relay incorporates patented differential voltage sensing and a non-positional mounting configuration to offer a single replacement for all standard potential relays. The UMSRe features advanced circuitry that intelligently discharges stray D.C. voltage from the starting capacitor to prevent contactor welding under extreme circumstances.

Standard Wiring Diagram

Alternative ReducedArcing Configuration

All Features and Specfications Subject to Change Without Notice

Wire-For-Wire Replacement For All Standard Potential Relays!Intelligent capacitor discharge circuitry provides anti-weld protection.

Part # Amps

24-UMSRE30 30

24-UMSRE50 50 NEW!

Dimension Diagrams

Page 8: Combustible Gas Leak Detector - MARKS SUPPLY · 2020-04-25 · Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible

alltemp heating special 08/098

2008/09 Heating Specialwww.alltemp.ca

Relay/Transformer Fan Centre AssemblyFan centre controls provide convenient low voltage control of one and two speed fan motors and auxiliary circuits in heating, cooling or heating/cooling applications. Each fan centre control is a reliable, compact unit consisting of a 24 volt control trans-former and a plug-in switching relay mounted on a 4" square electrical junction box cover. All line voltage connections are made inside the box with colour coded pre-stripped leads. Low voltage connections are made at a convenient terminal board mounted to the transformer.

Fan Control CentreFeatures

• DPDT or SPDT relay.• 24V coil voltage, power and duty rated

contacts.• Colour coded pre-stripped leads.• Low voltage terminal board.• Input Voltage 120V or 208/240V, Output

Voltage - 24V, 40 VA.• Mounts directly to 4" electrical box.• UL/ CUR File E237660.

Fan Control CentreTransformer Relay Contact Ratings

Part #Primary Secondary Full

Relay

120 VAC (amps)

240 VAC (amps) Resistive Cross Reference

Voltage Connection Voltage Connection LRA FLA LRA FLA

25-90113 120Colour coded pre-stripped

leads.24 V

Terminal board with 5 screw

terminals.DPDT 13.8 82.8 6.9 39.6

15 Amps @ 277 VAC.

Honeywell: R8285 Series.Mars: 90113.White Rodgers: 8A05A-101.

25-90113Illustrated

Features• Controls oil burner, oil valve (if desired) and the ignition transformer

in response to a call for heat .• Solid state flame sensing circuit .• LED on terminal strip indicates system lockout.• Enclosed safety switch with external reset button.• Mounts on standard 4" x 4" junction box; select models may be

mounted directly on burner housing.• 69-45610 Cadmium Sulfide Flame Detector and 24 VAC thermostat

required.• Direct replacement for popular competitive models.

Oil Primary Control - Intermittent IgnitionPart # Safety Timing Replaces

24-ICM1501 15 Sec Honeywell: R8184G4066, R8184G1161, R8184G1294

24-ICM1502 30 Sec Honeywell: R8184G4074, R8184G1179, R8184G1302, R8184G4033

24-ICM1503 45 SecCarlin: 48245 - Tempstar/Heil: 1147017 - White Rodgers: 668-401Honeywell: R8184G4009, R8184G1138, R8184G1427, R8184G4025

Oil Primary Control - Interrupted IgnitionPart # Valve on Delay (Seconds) Burner Motor Off Delay (minutes) Alarm Contacts Replaces

24-ICM1511 Selectable 0 - 15 Selectable 0 or 2,4,6 Yes Honeywell:R7184U

24-ICM1512 15 0,2,4,6 or 0.5,2,4, or 8 Optional Honeywell:R7184P

24-ICM1513 15 None None Honeywell:R7184B

24-ICM1514 None None None Honeywell:R7184A

Oil Primary ControlSpecifications

Ignition Type: Intermittent Timing, Safety Switch: 15, 30 or 45 seconds Mounting Bracket: For mounting on a standard 4" × 4" junction box or direct mounting on burner housing.Electrical Rating; Contacts (full load):7.4 A @ 120 VAC; 3.7 A @ 240 VAC Electrical Rating; Contacts (locked rotor):44.4 A @ 120 VAC; 22.2 A @ 240 VAC Dimensions:• 4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deep • 111 mm high x 104 mm wide x 64 mm deep Temperature Range: -30°F to +130°F Approvals • Underwriters Laboratories Inc

Dimensions

4.08"3.38"

2.35"2.03"

3.38"

4.41"

ø .18"

Thermostats - Fixed Temperature

3 Wire Fixed ThermostatsSwitched fan, 3 modes: • Fan Only• Off• Heat or Cool

Part # Description78-SC060S 60°F w/ switch - fan/off/ heat.78-SC065S 65°F w/ switch - fan/off/ heat.78-SC070S 70°F w/ switch - fan/off/ heat.78-SC075S 75°F w/ switch - fan/off/ cool.

2 Wire Fixed ThermostatsPart # Description

78-SC045 45°F cool.78-SC055 55°F cool.78-SC060 60°F heat.78-SC065 65°F heat.78-SC070 70°F heat.78-SC075 75°F cool.

Specifications Electrical Rating • 24 volt AC (18-30 VAC) • 2 amp maximum Temperature Control Ranges • Accuracy ±5°F 55°, 60°, 65°, 70°, 75°F

"Dry Out"

Thermostats

Fixed Temperature Thermostats• The 78-SC055 to 78-SC075S series of thermostats are low cost single set point

thermostats intended for temporary heating or cooling to allow drywall to dry during construction. Can also be used for low ambient cut-off switch.

• Rugged utility thermostat for temporary applications.• Ideal for new or ongoing construction areas.• Five fixed set point models to choose from (55°, 60°, 65°, 70°, 75°F).• Hardwired.

78-SC075 Illustrated 78-SC075S

Illustrated

Applications• Ideal for warehouses &

new home construction!

NEW!

Page 9: Combustible Gas Leak Detector - MARKS SUPPLY · 2020-04-25 · Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible

alltemp heating special 08/09 9

2008/09 Heating Specialwww.alltemp.ca

Fan Blower Controls

Off Delay on BreakControls the circulating fan in heat pump, air conditioning and forced air systems. OFF delay timing function continues to run the fan at the end of the heating/cooling cycle, thereby purging the ducts of residual air and increasing system efficiency.

Dual On/Off DelaysControls the circulating fan in heat pump, air conditioning and forced air systems. Delay on make lets air reach proper level prior to turning the fan on. OFF delay timing function continues to run the fan at the end of the heating/cooling cycle, thereby purging the ducts of residual air and increasing system efficiency.

Part # Features and Applications Specifications Replaces

24-ICM253

· UL 873 recognition for compressor applications· Post-purge fan delay timer

· Interrogation delay eliminates nuisance trips due to thermostat bounce/tampering

· Voltage:18-30VAC· 1 Amp Max· 40 mA Min.· 10 Amp Inrush· Adjustable time delay 12-390 seconds· Dimensions: 2"×3"

· Field Controls: 46144700· Gemline: 1C216· Mars: 32393

Part # Features and Applications Specifications Replaces

24-ICM251· Drives fan directly

· High power, relay output· Dual function fan relay timer

· Voltage:18-30VAC· Output: N.O.: 20 Amps @ 240VAC N.C.:10 amps @ 240VAC· Time Delays Adjustable On - 1-180 seconds Off - 12-390 seconds· Dimensions: 2"×3"

· Mars: 32377, 32378, 32379

24-ICM254

· Dual function fan timer· Controls the circulating fan in heat pump, A/C and

forced air systems

· Voltage:18-30VAC· 1 Amp Max· 40 mA Min.· 10 Amp Inrush· Time Delays Adjustable On - 1-180 seconds Off - 12-390 seconds· Dimensions: 2"×3"

· Honeywell: S876A1016· Watsco: PSTD-00-005W, PSTD-00-060W

24-ICM255

· Low cost open board design· High power, relay output

· Dual function fan delay timer

· Voltage:18-30VAC N.O.: 20 Amps @ 240VAC N.C.:20 amps @ 240VAC· Time Delays Fixed On - 1 second Off - 60 seconds· Dimensions: 2.5"×2.5"

· A-1: 5893· Bard: 8201-056· Mars: 32393· Rheem: 42-22515-01, 02, 03· Snyder General/ICP: 1395336

24-ICM251 24-ICM254 24-ICM255

24-ICM253

Page 10: Combustible Gas Leak Detector - MARKS SUPPLY · 2020-04-25 · Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible

alltemp heating special 08/0910

2008/09 Heating Specialwww.alltemp.ca

Fan Blower Controls

Part # Features and Applications Specifications Replaces

24-ICM270

· Dual function fan delay timer · Controls the circulating fan in a heat pump,

A/C and forced air systems · OFF delay purges ducts of residual air · ON delay allows air to reach the proper

comfort level prior to energizing the fan

Voltage: 18-30 VACFrequency: 50/60 HzHeat/Cool SpeedN.O.: 20 amps @ 240 VACN.C.: 10 amps @ 240 VACTime Delays Blower Off Time Adjustable90,120,150,180 seconds

· Evcon: 2702-300· Rheem: 47-22827-01, 81, 82, 47-22828-01, 02· Robertshaw: 695-003

24-ICM271

· Specifically designed to replace popular gas furnace centers

· Pin selectable blower delays · High power, relay output

· Dual function fan delay timer · Controls the circulating fan in heat pump, A/C

and forced air systems · OFF delay purges ducts for residual air · ON delay allows air to reach the proper

comfort level prior to energizing the fan

Voltage: 18-30 VACFrequency: 50/60 HzContact RatingsN.O.: 20 ampsN.C.: 10 ampsFixed Time DelaysON: 75 secondsOFF: 105 seconds

· Carrier: 302075-3, CES00110017/0018, HH84AA010/011/012 /013/020 P771-7002· Robertshaw: 695-100

24-ICM272

· Cooling control module with fan delay · Integral low voltage terminal board with field

thermostat wiring · Electronic air cleaner output

· High power, relay output · DC output for fan relays and 1st stage of

electric heater control · Interlock circuitry prevents 2nd and 3rd stage

electric heat energization without proper fan operation

Voltage: 18-30 VACFrequency: 50/60 HzContact RatingsN.O: 20 ampsN.C.: 10 ampsTime Delay Fixed60 seconds

· Carrier: HK61GA001/003· Texas Instruments: 2FD-1

24-ICM273

· Solid state output · Silent operation, \\\"no clicking\\\"

· Controls the circulating fan in heat pump A/C and forced air systems

· OFF delay purges ducts of residual air

Voltage: 18-30 VACFrequency: 50/60 HzOutput2 amps @ 240 VACTime Delay Fixes60 seconds

· EMI: 240000-969

24-ICM274

· Microprocessor-based fan blower control· Built in humidity relay

· Manually adjustable post-purge offdelay from 60-240 seconds

Voltage: 18-30 VAC - Y out: 1.5 amps - Fan: 2 amps - Electric heat relay: 30 amps @ 240 VAC - Blower off delay: 60 seconds

· EMI: 240-1764

24-ICM275

· Microprocessor-based fan blower control · Built in humidity relay

· Manually adjustable post-purge off delay from 60-240 seconds

· Electronic air cleaner output

Voltage: 18-30 VACFrequency: 50/60 HzContact Ratings:20 amps @ 240 VAC on high10 amps @ 240 VAC on lowTime DelaysON: 60 seconds fixedOFF: 60-240 seconds adjustable

· Carrier: CES0110019, HH84AA001/003/005/009/ 014/015/021· Robertshaw: 695-101

24-ICM276

· Microprocessor-based fan blower control· Inducer fan outputs

· Controls the circulating fan in gas/heat and A/C systems

· OFF delay purges ducts of residual air

Voltage: 18-30 VACOutput: - Fan:20 amps @240 VAC - Inducer fan: 2 ampsTime Delays (seconds) - Heat on delay: 60 - Heat off delay:120,150,180 - Cool off delay:60

· Carrier: HK51GA003· Rheem: 47-23619-02/03· Robertshaw: 457-23619-03 RS100-833-02

24-ICM277 · Microprocessor-based fan blower

· Controls the circulating fan in heat pump, A/C and forced air systems

Voltage: 18-30 VACContact RatingsN.O.: 20 ampsN.C.: 10 ampsTime DelaysON: 7 secondsOFF: 65 seconds

· Goodman: B13707355

Direct OEM Replacement Parts

NEW!

NEW!

Page 11: Combustible Gas Leak Detector - MARKS SUPPLY · 2020-04-25 · Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible

alltemp heating special 08/09 11

2008/09 Heating Specialwww.alltemp.ca

Freeze Protection Modules

Furnace Controls

Applications The ICM308/309/310 are low cost, fixed, single setpoint temperature controls that provide freeze protection.

Part # Temperature Cut Out (OFF) Temperature Cut In (ON)

24-ICM308 43°F 45°F

24-ICM309 28°F 55°F

24-ICM310 44°F 48°F

Part # Features and Applications Specifications

24-ICM30824-ICM30924-ICM310

· Low cost, fixed, single setpoint temperature controls that provide freeze protection

· Small compact package· Epoxy encapsulated for moisture protection

· Temperature sensor included

Input: - Voltage: 18-30 VAC - Frequency: 50-60 HzOutput - Solid state (triac)1.5 amps @ 30VACDimensions: - 2"×2"×1¼"

NEW!

Furnace Control Modules

Part # Features and Applications Specifications Replaces

24-ICM280

Low cost, direct replacement board for Goodman, Janitrol, TI, White-Rodgers and UTEC

Microprocessor based design for precise timing Functions with all 24 VAC thermostats

For 80+ and 90+ applications UL recognized

Voltage Range: Line (98 to 132 VAC) @ 60HzCool Blower: 10A, 2 HP, 240 VACHeat: 5A, 240 VACInducer Motor: 4A, FLA-8.0 LRA @ 120 VACGas Valve: 1.5A @ 30 VACHeat Blower on Delay: 30 secondsHeat Blower Off Delays: 90, 120 and 150 secCool Blower on Delay: 5 secondsCool Blower Off Delay: 60 seconds

· Goodman: B1809906/08/10/ 13/13S· UTEC:1012-933D· Texas Instruments: 41F-5· White-Rodgers: 50T35-730/743

24-ICM281

Low cost, direct replacement board for Carrier CESO11005700/01/02

Controls gas valve, ignitor, blower motor, inducer, humidifier and air cleaner

Microprocessor-based for precise timing Functions with all 24 VAC thermostats

Designed for 100% gas shutoff in case of ignition failure Twinning compatible with another ICM281 board

Voltage Range: Line (98 to 132 VAC) @ 60HzCool Blower: 10A, 2 HP, 240 VACHeat: 5A, 1/2 HP, 240 VACInducer Motor: 4A, FLA-8.0 LRA @ 120 VACGas Valve: 1.5A @ 30 VACHeat Blower on Delay: 40 secondsHeat Blower Off Delays: 90, 135, 180, and 225 secondsFan (Low) On/Off: 1-secondCool Blower on Delay: 5 secondsCool Blower Off Delay: 90 seconds

· Carrier: CESO110057-00/01/02

24-ICM282

Low cost, direct replacement for Carrier HK42FZ004/007/008/009/011/013/016

Controls gas valve, ignitor, blower motor, inducer, humidifier and air cleaner

Microprocessor-based Designed for 100% gas shutoff in case of ignition failure

Twinning compatible with another ICM282 board Diagnostic fault codes (blinking LED) to aid in troubleshooting

Voltage Range: Line (98 to 132 VAC) @ 60HzCool Blower: 10A, 2 HP, 240 VACHeat: 5A, 1/2 HP, 240 VACInducer Motor: 4A, FLA-8.0 LRA @ 120 VACGas Valve: 1.5A @ 30 VACHeat Blower On: 60 secondsHeat Blower Off: 90, 120, 150, and 180 secFan (Heat) On/Off: 1-secondCool On: 2 secondsCool Off: 90 seconds with jumper JW2 uncut; 5 seconds with jumper JW2 cut

· Carrier: HK42FZ004/007/008/009/ 011/013/016

24-ICM280 24-ICM281 24-ICM282

Page 12: Combustible Gas Leak Detector - MARKS SUPPLY · 2020-04-25 · Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible

alltemp heating special 08/0912

2008/09 Heating Specialwww.alltemp.ca

Drain Valve• Non-corrosive glass filled polymer const.• Unlike brass, will not deplete anode sys.

Part # Description39-DV7575 3/4" NPT × 3/4" NPT male .

Water Heater Valve

Forged Gas Ball Valves• Brass or plated outdoor.• Yellow lever handle.• 600 WOG full port.

Brass Indoor Plated Outdoor Description06-FGV38 06-FGV38P 3/8" FNPT × 3/8" FNPT06-FGV12 06-FGV12P 1/2" FNPT × 1/2" FNPT06-FGV34 06-FGV34P 3/4" FNPT × 3/4" FNPT06-FGV1 06-FGV1P 1" FNPT × 1" FNPT06-FGV114 06-FGV114P 1¼" FNPT × 1¼" FNPT06-FGV112 06-FGV112P 1½" FNPT × 1½" FNPT06-FGV2 06-FGV2P 2" FNPT × 2" FNPT

Appliance Forged Gas Ball Valves• Brass ball valves.• Red wing handle.• 600 WOG.

Part # Description06-GWH12 1/2" FNPT × 1/2" FNPT, 3/8" port.06-GWH34 3/4" FNPT × 1/2" FNPT, 1/2" port.

Gas Cock Valves

Brass Welded Ball Valves• Full Port.• Female sweat connection.• 600 WOG.• Green lever handle.

Part # Description06-SWV12 1/2" Sweat × 1/2" Sweat.06-SWV34 3/4" Sweat × 3/4" Sweat.

Water Valves

Forged Boiler Gate Valve• Brass drain valve. • Green handle.

Part # Description06-BGV12 1/2" MNPT × Hose.06-BGV34 3/4" MNPT × Hose.

Boiler Drain Valves

Brass (Indoor) or

Plated (Outdoor)

Applications Fireplace Forged Gas Ball Valves• Brass ball valves.• Red wing handle.• 600 WOG.

Part # Description06-FP1238 1/2" FNPT × 3/8" Male flare.06-FP1212 1/2" FNPT × 1/2" Male flare.06-FP3458 3/4" FNPT × 5/8" Male flare.

Appliance Forged Gas Ball Valves• Brass ball valves.• Yellow flat head.• 600 WOG.

Part # Description06-FHGV12 1/2" FNPT × 1/2" FNPT, 3/8" port.06-FHGV34 3/4" FNPT × 3/4" FNPT, 1/2" port.

Page 13: Combustible Gas Leak Detector - MARKS SUPPLY · 2020-04-25 · Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible

alltemp heating special 08/09 13

2008/09 Heating Specialwww.alltemp.ca

Ball BearingsBearings complete with collar.

Part # Bore OD Replaces67-4336-1

3/4" 1 13/16"LRCR

67-4336-2 (2) Bearings & (2) Collars

67-4346-1 1" 2 ¼" RCR

Sleeve Bearing PaksKits include 2 bearings & 2 rubber sleeves.

Part # Bore OD Type Replaces67-4036-2 3/4" 1 25/32"

OilDelhi

67-4046-2 1" 2 ½" Delhi

67-4135-2 5/8" 1 7/8"

Sealed

Lau

67-4136-23/4"

1 13/16"Delhi

67-4137-2 Lau & Lennox

67-4138-2 1 7/8" Torin

67-4146-21" 2 ½"

Delhi

67-4147-2 Lau & Lennox

67-4148-2 Torin

Bearings

Bearings & SleevesPart # Bore Type

67-4136-R 3/4" Rubber sleeve67-4146-R 1" Rubber sleeve67-4136-B 3/4" Sealed bearing67-4146-B 1" Sealed bearing67-4036-B 3/4" Oil bearing67-4046-B 1" Oil bearing

Thrust Collar PaksPart # Description

67-2164 (2) 5/8" collars & washers.67-2165 (2) 3/4" collars & washers.67-2166 (2) 1" collars & washers.

67-2165Illustrated

67-4136-RIllustrated

67-4136-BIllustrated

67-4046-BIllustrated

67-4036-2Oil Type Illustrated

67-4136-2Sealed Type Illustrated

67-4336-1Illustrated

Aluminum Pulleys

Variable Speed PulleysPart # Bore Diameter

67-4325

1/2"

3 1/4"67-4350 3 1/2"67-4375 3 3/4"67-4400 4"67-5325

5/8"

3 1/4"67-5350 3 1/2"67-5375 3 3/4"67-5400 4"Cast aluminum pulley mfg'd to OEM specs

Blower Pulleys - Continued

Part # Bore Diameter67-860

1"

6"67-870 7"67-880 8"67-890 9"67-810 10"67-812 12"

67-4325Illustrated67-660

Illustrated

ShaftsPart # Diameter Length Reference

67-61100

3/4"

11" Lennox, 210015767-61110 11 5/8" Lennox67-61212 12 3/4" 8-5-495C, 210000267-61400 14" 8-5-245C, 210015967-61550 15 5/16" G9, G12-9, 210016067-61600 16" 8-6-23608, WW15X36, 2100162, 2100163, 210019867-61610 16 5/8" 8-5-240C, G10, G110, 2100011, 210016167-61800 18" 8-5-247C, 8-5-241C, 2100012

67-61920 19 1/8" G12, 2100168

67-62000 20" M90-256, RS62067-62200 22" 210001367-62400 24" 8-5-243C67-63600 36"67-82000

1"20" G15-72, 2100165, 2100078, 2100081, 2100076

67-82400 25" 8-5-252C & 255C, M90-257, G15, 2100037, 55, 56, 210016667-83600 36" P-S-209, M90-270, 2100168, 2100052, 210054

Shafts

Shafts• Sized to bearing manufacturers

specifications.• Slabbed on pulley end.• Rust protected.• Individually wrapped.• Protective end caps.• Part number and

size listed on every shaft.

67-61610Illustrated

Blower PulleysPart # Bore Diameter

67-650*

3/4"

5"67-660 6"67-670 7"67-680 8"67-690 9"67-610 10"67-612 12"

* 5" pulley is solid

Page 14: Combustible Gas Leak Detector - MARKS SUPPLY · 2020-04-25 · Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible

alltemp heating special 08/0914

2008/09 Heating Specialwww.alltemp.ca

Combustion Chamber Liners

63-3WETPAKWet Pak Sheet

63-D11Illustrated

63-DP9, DP11, DP13 & DP15

Models

63-DP16 & DP20Models

63-10WETPAKPreshaped Wet Pak

Wet Paks• Seamless design complete with a bottom.• Pliable yet self supporting in a vertical position.

Pre Dried• Formed to a uniform thickness & density while maintaining a

hardness which has exceptional handling strength.• Easy to cut means more versatility in nozzle opening placement.

Features:• Fast easy installation - less than 30 min.• Low conductivity - high efficiency.• High sound absorption.• Lightweight: 5% of conventional firebrick.• High heat resistance (up to 2300°F).• Superior to steel brick or castable cham-

bers.• Individually sealed & packaged.• Comes with instructions.• Wall thickness 1/2" nominal.

Preshaped Wet Paks

Part # G.P.HInside

DiameterOutside Diameter

Height Weight

63-09WETPAK 0.50 to 0.75 8" 9" 15.5" 4.0 lbs.63-10WETPAK 0.75 to 1.00 9" 10" 15.5" 5.0 lbs.63-11WETPAK 1.00 to 1.25 10" 11" 15.5" 6.0 lbs.63-12WETPAK 1.25 to 1.50 11" 12" 15.5" 6.5 lbs.63-13WETPAK 1.50 to 2.00 12" 13" 15.5" 7.0 lbs.63-14WETPAK 2.00 to 2.50 13" 14" 15.5" 7.5 lbs.63-16WETPAK 2.50 to 2.75 15" 16" 15.5" 8.5 lbs.

Pre Dried

Part # G.P.H.Inside Diam-

eterOutside Diameter

Height Weight

63-D09 0.50 to 0.75 8" 8" 12.25" 2.25 lbs.63-D10 0.75 to 1.00 9" 10" 12" 3.0 lbs.63-DP09 0.65 to 0.85 9" 10.5" 15" 5.0 lbs.63-D11 1.00 to 1.25 10" 11" 12" 3.5 lbs.63-DP11 1.00 to 1.25 11" 12.5" 15" 6.5 lbs.63-D12 1.25 to 1.50 11" 12" 14" 4.0 lbs.63-D13 1.50 to 2.00 12" 13" 14" 4.25 lbs.63-D14 2.00 to 2.50 13" 14" 16" 5.0 lbs.63-DP13 1.35 to 1.75 13" 14.5" 15" 8.25 lbs.63-DP15 1.75 to 2.00 15" 16.5" 15" 9.5 lbs.63-DP16 1.75 to 2.25 10.5" × 15" 13" × 17.5" 15" 16 lbs.63-DP20 2.25 to 3.00 12" × 19.5" 14.5" × 22" 16" 17 lbs.

OEM Replacements63-D20 Grimsby 97 - 77 10.5" × 10.5" 11.5" × 11.5" 12" 3 lbs.63-D21 Grimsby 117 - 77 10.5" × 10.5" 11.5" × 11.5" 12" 3 lbs.63-D22 Grimsby 140 - 79 12" × 12.25" 13" × 13.5" 13" 4.5 lbs.63-D23 Grimsby 158 - 79 11.75" × 11.88" 13" × 13.88" 12" 4.5 lbs.63-D24 Grimsby W - 196 9.125" × 9" 10.125" × 10" 10.25" 3 lbs.63-D30 Esso #110 5 Component Set 12 lbs.63-D31 Esso #150 5 Component Set 15 lbs.

Wet Pak Sheets

Part # G.P.HInside

DiameterDimensions Weight

63-1WETPAK 1.25

Flat Sheet Sizes

14" x 48" × 0.5" 9.0 lbs.

63-2WETPAK 2.501pc. 14" x 48"× 0.5" &1pc. 16" x 16"× 0.5"

10.0 lbs.

63-3WETPAK 2.651pc.16" x 48"× 0.5" &1pc. 16" × 16"× 0.5"

10.25 lbs.

Page 15: Combustible Gas Leak Detector - MARKS SUPPLY · 2020-04-25 · Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible

alltemp heating special 08/09 15

2008/09 Heating Specialwww.alltemp.ca

Alltemp Humidifier Pads• Available for furnace or portable type.• Keep environment fresh and clean!• Increase efficiency and life of humidifier!

Furnace Type HumidifierPart # Make Model

70-3802-1• Carrier• Lau• Texaco

- LB18- VA2

70-3815-2S • Homart-Sears - 15

70-3817-2S • Lau - L17

70-3824-ISNC• Acquaduct• Essomatic• Metro-Vision

- 100555- 105- 240

70-3831-IS • Homart-Sears - 931

70-3840-ISN • Walton - WL-140

70-3841-ISN • Esso - Ultramatic 1624

70-3845-ISN• Montgomery-Ward• Wait-Skuttle

- 12- 45, 45S

70-3850-1 • Electrohome - FH450G

70-3867-ISN • General - 67

70-3897-ISN• Autoflo• Lennox

- 97- WD2-20Portable Type Humidifier

Part # Make Model70-3902-S • Electrohome - YH7S-301

70-3903-S • Wait-Skuttle - 1725-11

70-3906 • Air King - 64-07901-001

Humidifier Pads

70-3890-ISNIllustrated

70-3902-SIllustrated

Furnace Type Humidifier Pads

Portable Type Humidi-fier Pads

"OPAQUE"Hard Shell

Humidifier Tubing (Polyethylene)Part # OD. ID Length Working PSI

08-PT4X2X100

1/4"1/8"

100'

40008-PT4X2X1000 1000'08-PT4X.1701C

1/6"100'

08-PT4X.1702M 2000'08-PT5X3X100 5/16" 3/16" 100' 60008-PT6X4X100 3/8" 1/4" 100' 40008-PT8X6X100 1/2" 3/8" 100' 30008-PT10X8X100 5/8" 1/2" 100' 240

Larger rolls available.

Humidifier Tubing

Features• Hard shell.• Colour - opaque.

"CLEAR"Soft Shell

08-2501-100Illustrated

Drain Tubing (Poly-Vinyl)Part # ID OD Wall Length Max. PSI*

08-2506-100 3/16" 5/16" 1/16"

100'

5508-2500-100 1/4" 3/8" 1/16" 5508-2501-100 3/8" 1/2" 1/16" 4508-2515-100 3/8" 5/8" 1/8" 5508-2502-100 1/2" 5/8" 1/16" 3008-2503-100 5/8" 3/4" 1/16" 3008-2527-100 5/8" 7/8" 1/8" 4008-2505-SPEC 7/8" 1 1/8" 1/8" 3008-2503-SPEC 5/8" 13/16" 3/32" 3508-2508-SPEC 1" 1 1/4" 1/8" 2508-2504-50 3/4" 29/32" 5/64"

50'20

08-2505-50 7/8" 1 1/16" 3/32" 20* Max PSI @ 70°F / Operating Temperatures 70°F (Ideal) to 150°F (Max)

Drain Tubing

Alltemp Drain

Tubing

Will Not Kink!!!Features

• Soft shell.• Does not kink!• Colour - clear.• Individually boxed(c/w knock-out hole).

NOTE:Larger rolls or other

wall thicknesses avail-able upon request.

08-PT4X2X100 Illustrated

Page 16: Combustible Gas Leak Detector - MARKS SUPPLY · 2020-04-25 · Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible

alltemp heating special 08/0916

2008/09 Heating Specialwww.alltemp.ca

Silicone

General Purpose Sealant / AdhesivesContractor grade sealants and adhesives are formulated for professional contrac-tor use only and are available in a variety of general purpose styles for increased convenience and efficiency. The long-term reliability under extremely environmental conditions make these general purpose silicone adhesives the ideal rubber sealant for any interior or exterior job.

SiliconePart # Description

83-SCS1000C Clear83-SCS1000W White83-SCS1000A Aluminum83-SCS1000B Black83-IS806 Red "Hi-Temp"

83-SCS1000 Application Temperature: -37°C to 60°C (-35°F to 140°F).

Performance Temperature: -62°C to 204°C (-80°F to 400°F).

83-IS806 Performance Temperature: -60°C to 260°C (-75°F to 500°F).

83-IS806Hi-Temp Silicone

Illustrated

83-SCS1000WIllustrated

Cartridge Type Smoke Emitters

Part # TypeBurning Time

(seconds)Cartridge /

PackSmoke Emitted

(Cu. ft.)Weight /

Cartridge61-S210 Splintax 20 20 matches/ pk 20 0.35 oz.61-HT102 Fumax 45 10 150 1/10 lbs61-HT103 Fumax KS 90 10 600 1/3 lbs61-HT104 Ventax 180 5 1,200 2/3 lbs61-HT105 Datax 240 5 2,500 2 lbs61-HT107 Brandax KS 480 1 18,000 1 lbs

Smoke Emitters61-HT102

Illustrated 61-HT105Illustrated

61-S210Illustrated

Pen Type Smoke EmitterPart # Description

61-S220Contains 1 pen with 6/ pk replacement wicks. 6 wicks provide up to 3 hours of continuous smoke, or 360 individual 30 second tests.

61-S221 6 pack of replacement wicks in plastic case for 61-S220 smoke pen.

Smoke BottlesPart # Description

61-S101 10 Smoke bottles. Each bottle can be used for 24 hours after ampule has been broken.

Note: The smoke generated by smoke bottles is corrosive.

61-S101Illustrated

Powder-PuffersPart # Description

61-S201 10 Powder-Puffers.

61-S201Illustrated

61-S220Illustrated

61-S221Illustrated

Crankcase Heaters

Self Regulating! "Compressor Burnout Protection!"• When a refrigeration compressor shuts down or enters a long-off

cycle, liquid refrigerant migrates into its crankcase oil. Lubrication decreases and crankcase burnout can occur when operation re-sumes.

• Energy efficient, self-regulating design automatically varies output to maintain adequate oil temperature while permitting wrapping and crossover without burnout.

• Handles compressors up to 5 Hp, 120 or 240 volt applications.• Fits all crankcases with circumferences smaller than 49".

Crankcase Compressor Heaters - FreezGard™

Part # VoltsOutput @-18°C (0°F)

Output @16°C (60°F)

Weight

75-CCH1 12060W 35W

0.5 lbs.75-CCH2 240 0.5 lbs.

Raychem

Page 17: Combustible Gas Leak Detector - MARKS SUPPLY · 2020-04-25 · Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible

alltemp heating special 08/09 17

2008/09 Heating Specialwww.alltemp.ca

120V• Blue Cable - Steel Braid

Part # Watts/ft Power Length Weight75-H611050 6 120V 50' Box 3.0 lbs.75-H611100* 6 120V 100' Truck Pack 9.0 lbs.75-H611250 6 120V 250' Reel 17.0 lbs.

120V• Blue Cable - Steel Braid - Black Jacket

Part # Watts/ft Power Length Weight75-H612050 6 120V 50' Box 4.0 lbs.75-H612100* 6 120V 100' Truck Pack 10.0 lbs.75-H612250 6 120V 250' Reel 20.0 lbs.75-H612500 6 120V 500' Reel 43.0 lbs.75-H6121000 6 120V 1000' Reel 77.0 lbs.

240V• Red Cable - Steel Braid - Black Jacket

75-H622050 6 240V 50' Box 4.0 lbs.75-H622100* 6 240V 100' Truck Pack 10.0 lbs.75-H622250 6 240V 250' Reel 20.0 lbs.75-H622500 6 240V 500' Reel 43.0 lbs.75-H6221000 6 240V 1000' Reel 77.0 lbs.

* 100' Truck Packs include (2) 75-H900, (1) 75-H903 & (1) 75-H910.

240V• Red Cable - Steel Braid

75-H621050 6 240V 50' Box 3.0 lbs.75-H621100* 6 240V 100' Truck Pack 9.0 lbs.75-H621250 6 240V 250' Reel 17.0 lbs.

* 100' Truck Packs include (2) 75-H900, (1) 75-H903 & (1) 75-H910.

Self Regulating Heat Cable

Keep Wet Areas From FreezingWith WinterGard Wet for tracing air

conditioner drain pans to prevent freezing or gut tracing freezer drain lines to prevent

backup problems.

Protect PipesWith WinterGard or Winter-

Gard Plus for freeze protection of short & small diameter pip-ing. Pre-cut lengths or custom

cut lengths.

Applications- Ideal freeze protection for pipes in un-

heated attics, basements and garages.- Use it for intake and drain lines, water

meters, outside pipes and taps.

Applications- Ideal for residential & commercial build-

ings.- Use it to freeze protect water service &

fire protection systems.- Roof & gutter de-icing.

WinterGard Heating Cable• Economical solution for residential/ commercial pipes up

to 2" diameter and circuit length up to 250'.• Dry applications only. • Tough - steel braided.

WinterGard Plus Heating Cable• Designed for more demanding residential/ commercial

with larger plastic or metal pipes with diameters up to 8" and circuit lengths up to 250'.

• Dry applications only. • Tough - steel braided.

WinterGard Wet Heating Cable• The answer for freeze protection in wet or high moisture

residential/ commercial locations such as drain lines with larger plastic or metal pipes. Suitable for pipe diam-eters up to 8" and circuit lengths up to 1000'.

• Wet or dry applications. • Tough - steel braided & waterproof outer jacket.

"Self Regulating"Heating Tape

• Easy installation• Won’t burn out• Won’t overheat• OK to overlap• OK to insulate

• OK for plastic• No thermostat required• Cut to desired length• Higher efficiency• UL & CSA approved

****WinterGard Wet ***WinterGard Plus **WinterGard

18 AWG Bus Wires

Conductive Core

Tinned Copper Braid***

Insulating Jacket**

Waterproof Outer Jacket****

Raychem

Page 18: Combustible Gas Leak Detector - MARKS SUPPLY · 2020-04-25 · Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible

alltemp heating special 08/0918

2008/09 Heating Specialwww.alltemp.ca

AccessoriesPart # Description Weight

75-H900 Power connection kit. 0.5 lbs.75-H903 Fibreglass application tape & "Electric traced" labels. 0.3 lbs.75-H908 Plug-in Power connection kit. 1.0 lbs.75-H910 Splice & tee kit. 0.3 lbs.75-FGK-P-RS "Original" termination kit. 0.3 lbs.75-H911* Plug-in power connection kit. 0.5 lbs.75-H912 Gel-filled end seal kit (2 ea.) 0.3 lbs.75-H913 Roof clips (10 ea.) 1.0 lbs.75-H914 Roof clips (50 ea.) 4.0 lbs.75-H915 Downspout hanger bracket. 0.5 lbs.75-H921 120V junction box with ELCI. 4.0 lbs.75-H931 Plug-in GFCI adapter. 1.0 lbs.75-AMC-F5 Fixed point thermostat 5°C (40°F). 1.5 lbs.

75-TC-32 receptacle thermo cube thermostatically controlled outlet (120V, 15 amp).- ON @ 2°C (35°F), OFF @7°C (45°F).

1.0 lbs.

*75-H911 connection kit is for use only with 75-H311 series heating cables. Plug includes GFI.

Self Regulating (Pre-assembled) Heat Cable

120VPart # Watts/ft Volts Length Weight

75-W51-6P 5 120V 6' Kit 1.0 lbs.75-W51-12P 5 120V 12' Kit 1.3 lbs.75-W51-18P 5 120V 18' Kit 1.6 lbs.75-W51-24P 5 120V 24' Kit 2.0 lbs.75-W51-50P 5 120V 50' Kit 3.3 lbs.75-W51-75P 5 120V 75' Kit 5.4 lbs.75-W51-100P 5 120V 100' Kit 6.9 lbs.

240V75-W52-6L 5 240V 6' Kit 1.0 lbs.75-W52-12L 5 240V 12' Kit 1.3 lbs.75-W52-18L 5 240V 18' Kit 1.6 lbs.75-W52-24L 5 240V 24' Kit 2.0 lbs.

Gardian Pre-assembled Heating Cable Kits• Perfect for residential or commercial small applications

with short pipe runs up to 100', 2" diameter. • Rugged copper braid provides abrasion and damage

protection.• 120V (30" power cord & plug) 240V (hardwired).

75-H611250250' Reel Illustrated

75-H61105050' Box Illustrated

75-H611100100' Truck Pack Illustrated

75-FGK-P-RSTermination Kit

Illustrated

75-W51-6PIllustrated

Gardian Pre-assembled

Heating Cable

Accessories - Self Regulating Heat Cable

Self Regulating Heat Cable - Continued

Standard Packaging• Winter Guard.• Winter Guard Plus.• Winter Guard Wet.

Raychem

Raychem

Raychem

Page 19: Combustible Gas Leak Detector - MARKS SUPPLY · 2020-04-25 · Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible

alltemp heating special 08/09 19

2008/09 Heating Specialwww.alltemp.ca

Rubberized Cork Insulation Tape

Wraptite Rubberized Cork Insulation TapeFormulated to provide insulation and to prevent condensation on hot or cool pipes, fittings and tubing used in heating, air conditioning, refrigera-tion and plumbing applications. Cork Insulation Tape adheres well to most clean, dry surfaces and to itself, making it possible to apply more than one layer without adding fasteners or adhesives.

It is sufficiently soft and pliable enabling it to be molded around most fitting or connections. The material retains it's flexibility and adhesion after prolonged exposure to UV and over a service temperature range of -29°C to 88°C (-20°F to 190°F). Cork Insulation Tape is black in colour and has a grainy, rubber-like consistency which is non-toxic and non-asbestos.

84-PT-30Illustrated

Wraptite Foam Insulation TapeFoam Insulation Tape is designed to seal, insulate and isolate vibration in air conditioning and refrigeration applications. The soft, flexible, closed cell sponge tape with paper covered self-adhesive backing seals out air and moisture while reducing heat loss or transfer. Cold water pipes, valves, chilled water and refrigeration lines can be wrapped to prevent sweating or condensation while hot water pipes and pipe heaters can be wrapped to insulate against heat loss.

Easily applied by hand, Wraptie Foam Insulation Tape adheres well to most clean, dry surfaces and to itself, making it possible to apply more than one layer. The formulated operating temperature of Wraptite Foam Insulation Tape is between -34°C to 82°C (-30°F to 180°F) with the ability to intermittently tolerate temperature of 98°C (210°F).

84-FT-30Illustrated

Wraptite Slugs & CordsSealing slugs & cord are soft, permanently pliable, water-resistant seal-ants having a wide variety of applications. The product has the unique quality of retaining the same consistency throughout its application range of -7°C to 60°C (20°F to 140°F). Non-asbestos and non-hardening, remains flexible to -7°C (-20°F).

Sealing slugs & cords are used widely in the air conditioning and refrig-eration industries to seal around outer cases, behind hinges and under breaker strips. They can be used to seal out air or moisture around utility panels, cables, ducts, window frames and metal joints. This product adheres to metal, wood, glass, plastic and most clean surfaces to provide an effective barrier against water, moisture, dirt and dust. It is non-stain-ing, non-bleeding, odorless and can be painted.

84-PS-30Illustrated

84-PC-30Illustrated

Foam Insulation Tape

Slugs & Cords

Wraptite's Standard Packaging

Includes, directions, bar-coding and complete product

line descriptions both in French & English.

Cork TapePart # Description

84-PT-30 1/8" × 2" × 30' Roll

Foam TapePart # Description

84-FT-30 1/8" × 2" × 30' Roll

Slugs & CordsPart # Description

84-PC-30 3/8" × 25' Cord84-PS-30 2 lb. Slug84-PS30-B 50 lb. Bulk Slug

Page 20: Combustible Gas Leak Detector - MARKS SUPPLY · 2020-04-25 · Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible

alltemp heating special 08/0920

2008/09 Heating Specialwww.alltemp.ca

ATPH071008

ROTOM®, R-LINE®, HOTEMP® are registered trade marks of ALLTEMP® PRODUCTS COMPANY LIMITED. ALLTEMP® has made an effort to illustrate with photos, outline drawings and/or descriptions, the products in this catalogue. These are for the sole purpose of identification. We do not express or imply that products conform exactly to the descriptions, drawings and/or photos. All reasonable effort has been made to accurately determine a suitable product. However, all users are solely responsible to evaluate and determine for themselves the suitability of the product purchased for the use intended. All information, data and dimension tables in this catalogue have been carefully compiled and thoroughly checked. However, no responsibility for possible errors or omissions can be assumed. The company reserves the right to change specifications and other information included in this catalogue without notice. The vendor’s responsibility shall be limited only to its written warranty and the vendor shall not be responsible for any loss, cost or damage whatsoever from the use of this product by you or your customers.

Reduce Inventory!ATP thermostat guards come complete

with hardware, ring and solid bases.

Plastic Thermostat Guards

Features• Hi-impact plastic guards.• Horizontal and vertical mounting.• Heavy duty lock and key.• Comes with complete mounting hardware.• Each model includes a ring & solid base.• Colour - clear cover with off white base.

77-PG3Illustrated

Metal Thermostat Guards

Part # BaseInside Dimensions

Cross ReferenceL W D

77-MG3Ring 5.31" 4.31" 3.00" BTG-KWM KMRT

Solid 5.62" 5.12" 2.87" BTG-KM KMST

77-MG6Ring 6.31" 3.62" 3.18" BTG-EM EMST

Solid 6.62" 4.12" 3.75"BTG-RMBTG-RWM

RMRT

77-MG9Ring 6.75" 4.50" 3.43" BTG-UWM UMRT

Solid 7.18" 5.25" 3.43" BTG-UM UMST

77-MG12R* Ring 6.12" 3.81" 3.12" BTG-54VLW F29-0256

77-MG12S* Solid 6.37" 4.25" 3.00" BTG-54VL F29-0255

* Hinged metal guards do not come with both bases.

Metal Thermostat Guards

Features• Durable metal guards.• Horizontal and vertical mounting.• Heavy duty lock and key.• Comes with complete mounting hardware.• Each model includes a ring & solid base.*• Colour - off white cover with off white base.

77-PG9Illustrated

77-PG6Illustrated

Reduce Inventory!ATP thermostat guards come complete

with hardware, ring and solid bases.

Mounting Base Types77-MG3 Plastic77-MG6 Plastic77-MG9 Metal77-MG12R Metal77-MG12S Metal

Mounting Base TypesAll mounting bases are

plastic.

Plastic Thermostat Guards

Part # BaseInside Dimensions

Cross ReferenceL W D

77-PG3Ring 3.75" 3.50" 2.62" BTG-EK F29-0252

Solid 4.00" 4.00" 2.50" ECST029-0178029-0179

77-PG6Ring 5.25" 4.62" 3.12" BTG-K F29-0251

Solid 5.75" 5.00" 2.81" KCBT F29-0257

77-PG9Ring 6.31" 3.62" 3.06" BTG-RK F29-0253

Solid 6.62" 4.12" 2.75" RCBT 029-0143

77-PG12Ring 8.18" 4.62" 3.56" BTG-UK F29-0254

Solid 8.50" 5.00" 3.87" UCBT 029-0198

77-MG3Illustrated

77-MG6Illustrated

77-MG9Illustrated

77-MG12R - HingedIllustrated

77-PG12Illustrated