2
Column Range Technical Data Column 3 Column 4 Column 2 Column 2 Vertical Floor Mounting Brackets are available from stock Due to production tolerances, the length of the product and therefore the tap centres could contain a variation of +/- 1.5% of the overall stated length. Column 2 Btu/hr @ rt50˚C Column 2 Vertical Btu/hr @ rt50˚C Height Length Henrad Heat emissions mm mm Code Watts Btu/hr 628 263012 499 1703 858 263013 691 2358 1042 263014 845 2884 1272 263015 1037 3539 628 263028 589 2010 858 263029 815 2782 1042 263030 997 3403 1272 263031 1223 4174 600 500 Height Length Henrad Heat emissions mm mm Code Watts Btu/hr 352 263054 868 2962 444 263055 1116 3809 352 263056 966 3296 444 263057 1242 4239 352 263058 1197 4085 444 263059 1539 5253 1800 2000 2500 Column 3 Btu/hr @ rt50˚C Column 4 Btu/hr @ rt50˚C Height Length Henrad Heat emissions mm mm Code Watts Btu/hr 444 263000 288 983 628 263001 416 1420 858 263002 576 1966 1042 263003 704 2403 1272 263004 864 2949 1456 263005 992 3386 1870 263006 1280 4369 444 263016 464 1584 628 263017 671 2290 858 263018 929 3171 1042 263019 1135 3874 1272 263020 1393 4754 1456 263021 1600 5461 1870 263022 2064 7044 444 263032 548 1870 628 263033 792 2703 858 263034 1096 3741 1042 263035 1340 4573 1272 263036 1644 5611 1456 263037 1888 6444 1870 263038 2436 8314 858 263044 1337 4563 1042 263045 1635 5580 1272 263046 2006 6846 1456 263047 2303 7860 1870 263048 2972 10143 500 600 750 Height Length Henrad Heat emissions mm mm Code Watts Btu/hr 444 263007 377 1287 628 263008 545 1860 858 263009 754 2573 1042 263010 922 3147 1272 263011 1131 3860 444 263023 608 2075 628 263024 879 3000 858 263025 1217 4154 1042 263026 1487 5075 1272 263027 1825 6229 444 263039 718 2451 628 263040 1037 3539 858 263041 1436 4901 1042 263042 1756 5993 1272 263043 2155 7355 444 263049 877 2993 628 263050 1266 4321 858 263051 1753 5983 1042 263052 2143 7314 1272 263053 2630 8976 500 600 750 300 300

Upload: others

Post on 05-Apr-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Column Range

Column RangeTechnical Data

Column 3

Column 4

Column 2

Column 2 Vertical

Floor Mounting Bracketsare available from stock

Due to production tolerances, the length of theproduct and therefore the tap centres couldcontain a variation of +/- 1.5% of the overallstated length.

Column 2

Btu/hr @ rt50˚C

Column 2 Vertical

Btu/hr @ rt50˚C

Height Length Henrad Heat emissions mm mm Code Watts Btu/hr

628 263012 499 1703

858 263013 691 2358

1042 263014 845 2884

1272 263015 1037 3539

628 263028 589 2010

858 263029 815 2782

1042 263030 997 3403

1272 263031 1223 4174

600

500

Height Length Henrad Heat emissions mm mm Code Watts Btu/hr

352 263054 868 2962

444 263055 1116 3809

352 263056 966 3296

444 263057 1242 4239

352 263058 1197 4085

444 263059 1539 5253

1800

2000

2500

Column 3

Btu/hr @ rt50˚C

Column 4

Btu/hr @ rt50˚C

Height Length Henrad Heat emissions mm mm Code Watts Btu/hr

444 263000 288 983

628 263001 416 1420

858 263002 576 1966

1042 263003 704 2403

1272 263004 864 2949

1456 263005 992 3386

1870 263006 1280 4369

444 263016 464 1584

628 263017 671 2290

858 263018 929 3171

1042 263019 1135 3874

1272 263020 1393 4754

1456 263021 1600 5461

1870 263022 2064 7044

444 263032 548 1870

628 263033 792 2703

858 263034 1096 3741

1042 263035 1340 4573

1272 263036 1644 5611

1456 263037 1888 6444

1870 263038 2436 8314

858 263044 1337 4563

1042 263045 1635 5580

1272 263046 2006 6846

1456 263047 2303 7860

1870 263048 2972 10143

500

600

750

Height Length Henrad Heat emissions mm mm Code Watts Btu/hr

444 263007 377 1287

628 263008 545 1860

858 263009 754 2573

1042 263010 922 3147

1272 263011 1131 3860

444 263023 608 2075

628 263024 879 3000

858 263025 1217 4154

1042 263026 1487 5075

1272 263027 1825 6229

444 263039 718 2451

628 263040 1037 3539

858 263041 1436 4901

1042 263042 1756 5993

1272 263043 2155 7355

444 263049 877 2993

628 263050 1266 4321

858 263051 1753 5983

1042 263052 2143 7314

1272 263053 2630 8976

500

600

750

300

300

Page 2: Column Range

Technical information

Testing and Operating PressuresHenrad Column Range has been independently testedto ensure these radiators perform to a maximumworking pressure of 8.0 bar.

ConnectionsEach radiator comes with 1/2" inlet connections asstandard.

Paint ProcessTwo coat paint process, each Henrad radiator issubjected to a multi-stage cleaning and paint process.

The final powder coat is Traffic white (RAL 9016)which is stoved and cooled to give a perfect finish.All radiators are illustrated in Traffic white unless stated.

Water TreatmentInstallation of the system should be properly flushedand fitted in accordance with the British Code ofPractice for the Treatment of Water in Domestic HotWater Central Heating Systems.

WarrantyHenrad Column Range comes with a 5 year manufacturer’s warranty.

Henrad (UK) Limited, Marriott Road,Mexborough, South Yorkshire S64 8BN.Telephone: 0844 543 6200 Facsimile: 0844 543 6300

www.henrad.co.uk

Henrad Column Range

Measurements using 10mm CVD Bracket Slot(add 5mm if using 15mm Slot) WA D D22 Column 23 54 853 Column 23 73 1234 Column 23 91 159

Number of CVD BracketsBH Clamps Required Number of sections4 0 - 236 24 - 41

Number of Feet Required Number of sections2 0 - 233 24 - 41

Accessories163061 Wall bracket retaining spring163062 Wall bracket clamp for classic column (BH)163060 Wall bracket (CVD)

Column RangeTechnical Data

Column floor mounting brackets

Available from stockUIN 148137(sold in pairs)

A9016Traffic white

Working pressure:Tested to withstand 8.0 bar

For technical and installationinformation visit our websitewww.henrad.co.uk/downloads

Wall Mounting InformationAll dimensions in mm.

D2

WA

Clamp

Bracket

D 150mm recommendedminimum