SITE KEY PLAN
PROPERTY ADDRESS: 6 CAMERON ST
COLLINGWOOD, ONTARIO
L9Y 2J2
OWNER: SIMCOE COUNTY DISTRICT SCHOOL BOARD
1170 ON-26
MIDHURST, ONTARIO
L9X 1N6
APPLICANT: MC ARCHITECTS INC.
(OWEN SOUND OFFICE)
201-870 3RD AVE EAST
OWEN SOUND, ONTARIO
M4S 3C4
TEL. 519-376-8210 FAX 519-376-3112
COLLINGWOOD
COLLEGIATE INSTITUTE
C
A
M
E
R
O
N
S
T
C
A
M
E
R
O
N
S
T
C
O
L
L
IN
S
S
T
C
A
M
P
B
E
L
L
S
T
C
A
M
P
B
E
L
L
S
T
L
O
C
K
H
A
R
T
S
T
M
A
P
LE
S
T
H
U
R
O
N
T
A
R
IO
S
T
F
A
IR
S
T
25mm COMPRESSIBLE MATERIAL
25
75 X 75 X 6L X 75 LG
EACH SIDE OF THE WALL.
SPACE ANGLES AT
1200mm O.C. AND
STAGGER EACH SIDE OF
THE WALL
EXISTING STRUCTURE
D1 MASONRY WALL LATERAL SUPPORT DETAIL 1: 10
COLLINGWOOD COLLEGIATE
LIFE SKILLS SUITE RENOVATION
6 CAMERON ST, COLLINGWOOD, ON L9Y 2J2
DRAWINGS LIST
A01
A03
A02
DRAWING LIST, LEGEND AND SITE KEY PLAN
GROUND FLOOR - KEY PLAN / DETAILS
ARCHITECTURAL
PARTIAL GROUND FLOOR - DEMOLITION AND NEW WORK
MC ARCHITECTS INC.
p: 519-376-8210 f: 519-376-3112
A04 PARTIAL GROUND FLOOR RCP - NEW WORK / SCHEDULES / DETAILS
2.
1.
NOTES FOR CONSTRUCTION LEGEND:
EXTEND ALL INTERIOR PARTITIONS TO UNDERSIDE OF EXISTING STRUCTURE.REFER TO PLANS FOR LOCATION OF FIRE RATED PARTITIONS AND FIRE SEPARATIONS.
COMPLY FULLY WITH REQUIREMENTS LISTED UNDER THE SPECIFIC ULC DESIGN No. IN THEUNDERWRITERS' LABORATORIES OF CANADA LIST OF EQUIPMENT AND MATERIALS, FIRERESISTANCE, (LATEST EDITION) OR THE SPECIFIC WH DESIGN No. IN THE INTERTEK ETL SEMKODIRECTORY OF LISTED BUILDING PRODUCTS, (LATEST EDITION).
ROOM NUMBER
ROOM NAME
DOOR No. - SEE DRAWING 1/A03 & 3/A04
WALL SECTION No.
DRAWING No. AXX
X
ROOMXXX
XXX
SYMBOLS LEGEND
MECHANICAL
M101LEGENDS, SCHEDULES, GENERAL NOTES & DETAILS
M201 GROUND FLOOR DEMOLITION PLANS
p: 519-725-3555 f: 519-725-2515
DEI & ASSOCIATES INC.
ELECTRICAL
E101 LEGENDS, SCHEDULES & DETAILS
E102 LIGHT CONTROLS
p: 519-725-3555 f: 519-725-2515
DEI & ASSOCIATES INC.
A05 DETAILS
A06 DETAILS
A07 DETAILS
E201 GROUND FLOOR DEMOTION / RENOVATION PLANS
E301 SPECIFICATIONS
M301 GROUND FLOOR RENOVATION PLANS
M401 SPECIFICATIONS
CONSTRUCTION - TYPICAL DETAIL
ONTARIO BUILDING CODE INFORMATION - Part 11 Renovation
C:\MCA\LOGOS\mcarchitects B&W.jpg
DRAWING LIST, LEGENDAND SITE KEY PLAN
B.W.
N.T.S. A011
Project
Sheet Title
Scale
Drawn
Project No.
Checked
Of
Sheet No.
THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL FIELDDIMENSIONS AND SHALL NOTIFY THE ARCHITECT OF ANY SITE CONDITIONSOR FIELD DIMENSIONS WHICH MAY BE AT VARIANCE WITH THE DRAWINGS.
THIS DRAWING IS NOT TO BE SCALED.
Date Issue
No. Date Revision
COLLEGIATE LIFE SKILLS SUITE RENOVATION
SIMCOE COUNTY DISTRICT SCHOOL BOARD
Midhurst Ontario
P.N.
19042 7
mc architectsmcarch.com
Toronto Office:1881 yonge street suite 400 toronto ontario m4s 3c4phone 416 489 4646 fax 416 489 6989
Offices: TORONTO - OWEN SOUND
Owen Sound Office:201-870 3rd ave east owen sound ontario m4s 3c4phone 519 376 8210 fax 519 376 3112
COLLINGWOOD
2020-06-29 ISSUED FOR TENDER & BUILDING PERMIT
1:5
25
FIRE RESISTANT RATED JOINT ASSEMBLY:
-cUL Design No. HW-D-0098;
-ULC Design No. HW23; 012
-cUL Design No. HW-D-0092 (CONFIGURATION A & B)
FLUTED STEEL FLOOR
OR ROOF DECK
CONTINUOUSLY FILL
FLUTED OPENING WITH FIRE
STOPPING AND SMOKE
SEAL
CONTINUOUS FIRE RATED
SEALANT SMOKE
SEAL-OVERLAP 13mm MINIMUM
ONTO MASONRY AND STEEL
DECK ON BOTH SIDES OF
PARTITION
CONTINUOUS FULL
THICKNESS MINERAL FIBRE
FIRE STOPPING INSULATION
-COMPRESS MIN. 50%
MASONRY
PARTITION
MASONRY
PARTITION
BEYOND
SECTION ELEVATION
.1 PARTITION PARALLEL TO
DECK FLUTES
.2 PARTITION PERPENDICULAR TO
DECK FLUTES
25 M
IN
.
EXISTING MASONRY PARTITION
EXISTING STEEL JOIST
FIRE STOPPING AND SMOKE SEAL
BULLNOSED CMU TYPICAL
ABOVE FIRST COURSE
STANDARD SQUARE CORNER CMU FIRST
COURSE - GRIND PORTION ABOVE
BASE TO MATCH BULLNOSED CMU
SQUARE CORNER PIECE
CERAMIC TILE - REFER TO
ROOM FINISH SCHEDULE
EXTEND BULLNOSED
CMU TO FLOOR
WRAP RESILIENT
BASE AROUND
BULLNOSED CORNER
DETAIL AT CERAMIC BASE
DETAIL AT RESILIENT BASE
1
A03
NE
W W
OR
K
2
A03
DE
MO
LIT
IO
N
E
X
I
S
T
I
N
G
C
O
N
T
I
N
U
O
U
S
C
U
R
B
CO
UR
TY
AR
D
COURTYARD
N
1
A04
NE
W R
CP
Project
Sheet Title
Scale
Drawn
Project No.
Checked
Of
Sheet No.
THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL FIELDDIMENSIONS AND SHALL NOTIFY THE ARCHITECT OF ANY SITE CONDITIONSOR FIELD DIMENSIONS WHICH MAY BE AT VARIANCE WITH THE DRAWINGS.
THIS DRAWING IS NOT TO BE SCALED.
Date Issue
No. Date Revision
COLLEGIATE LIFE SKILLS SUITE RENOVATION
SIMCOE COUNTY DISTRICT SCHOOL BOARD
Midhurst Ontario
P.N.
19042 7
mc architectsmcarch.com
Toronto Office:1881 yonge street suite 400 toronto ontario m4s 3c4phone 416 489 4646 fax 416 489 6989
Offices: TORONTO - OWEN SOUND
Owen Sound Office:201-870 3rd ave east owen sound ontario m4s 3c4phone 519 376 8210 fax 519 376 3112
COLLINGWOOD
2020-06-29 ISSUED FOR TENDER & BUILDING PERMIT
GROUND FLOOR - KEY PLAN/ DETAILS
B.W.
AS NOTED A022SCALE
GROUND FLOOR - KEY PLAN
1:350
1
A02SCALE
BASE DETAIL AT BULLNOSED CORNER
1:10
2
A02
SCALE
JOIST PERPENDICULAR TO PARTITIOIN
1:5
3
A02
SCALE
FIRE STOPPING & SMOKE SEAL AT MASONRY PARTITION
1:5
4
A02
ALUMINUM TRIM ALL SIDES
WALL MOUNTED
WHITE BOARD OR TACK BOARD
WALL
WHITE BOARD / TACK BOARD
DIM
. T
O B
E C
ON
FIR
ME
D O
N S
IT
E
NEW CONSTRUCTION NOTES ( INDICATED BY: )
1. NEW HOLLOW METAL DOOR & FRAME. SEE DOOR SCHEDULE. DOOR & FRAME FOR PAINT
FINISH.
2. INFILL EXISTING DOOR OPENING WITH NEW 140 CMU. NEW CMU TO BE FLUSH ON
UNIVERSAL WASHROOM / MAIN ROOM SIDE OF WALL.
3. PROVIDE NEW 125mm THICK CONCRETE SLAB ON GRADE ON COMPACTED GRAN FILL
AFTER INSTALLATION OF NEW UNDERGROUND MECHANICAL SERVICES. PIN NEW
CONCRETE SLAB TO EXISTING WITH 15M STEEL DOWELS. DOWELS AT 300mm O.C.
DOWELS 400mm LONG. DRILL AND GROUT DOWEL INTO EXISTING CONCRETE SLAB
200mm DEEP. - TYPICAL ALONG ALL SIDES / EDGES OF NEW SLAB. THICKEN SLAB AS
REQUIRED AND PROVIDE SLOPE SLAB IN NEW SHOWER AREA. SEE SECTION DETAIL.
4. NEW 140mm CMU PARTITION TO U/S OF EXISTING STRUCTURE. PARTITION TO BE
PAINTED. NEW MASONRY CHASE WALLS TO 200mm ABOVE FINISHED CEILING.
5. MAKE GOOD EXISTING CMU AS REQUIRED AT NEW WIDER DOOR OPENING.
6. PATCH AND MAKE GOOD SLAB ON GRADE AS REQUIRED DUE TO REMOVAL OF OLD
RECESSED ELECTRICAL RECEPTACLES.
7. PROVIDE NEW SUSPENDED CEILINGS THROUGHOUT. SEE REFLECTED CEILING PLAN ON
DRAWING A04.
8. PROVIDE NEW SPRAY CEMENTITIOUS FIREPROOFING OF ALL STEEL STRUCTURE AND
FLOOR ASSEMBLY ABOVE. FIREPROOFING TO CONFORM TO ULC DESIGN NO. F818.
SPRAY FIREPROOFING REQUIRED THROUGHOUT ENTIRE AREA OF RENOVATION.
9. INSPECT ALL EXISTING JOIST PENETRATIONS OF CONCRETE BLOCK CORRIDOR WALL.
FIRE STOP ALL JOIST PENETRATIONS. ALLOW FOR 16 JOIST PENETRATIONS. SEE DETAIL
3/A02.
10. EXISTING RAD COVERS TO BE REPLACED. SEE MECHANICAL DRAWINGS.
11. FIRESTOP AND SEAL TOP OF EXISTING MASONRY CORRIDOR WALL FOR ENTIRE LENGTH
OF WALL IN AREA OF NEW WORK. SEE DETAIL 4/A02.
12. MAKE GOOD EXISTING BULKHEAD / CEILING ABOVE LOCKERS AS REQUIRED AFTER
COMPLETION OF NEW MECHANICAL WORK. FOR FIRE DAMPER AT EXISTING MASONRY
PARTITION, SEE DETAIL 6/A07.
13. SUPPLY AND INSTALL NEW WINDOW SHADES.
XX
TOILET TISSUE DISPENSER - SEE DETAIL 3/A05
SANITARY NAPKIN DISPOSAL BIN - SEE DETAIL 4/A05
HAND DRYER - SEE DETAIL 4/A05
FIXED FRAME MIRROR - SEE DETAIL 2/A05 & 4/A05
WASHROOM L-SHAPED GRAB BAR - SEE DETAIL 3/A05
WASHROOM SHELF
SOAP DISPENSER, N.I.C. - SEE DETAIL 2/A05
COAT HOOK
3
6
2
7
4
8
5
1
NOTE: SUPPLIED BY OWNER, INSTALLED BY GC
NOTE: SUPPLIED BY OWNER, INSTALLED BY GC
EMERGENCY CALL BUTTON AND SIGN, SEE DETAIL 7/A059
WASHROOM ACCESSORY LEGEND
DRAWING SYMBOL LEGEND
EXISTING WALL TO REMAIN
EXISTING WALL / ITEM TO BE REMOVED
FLOOR FINISH LEGEND
FINISHFINISH
FLOOR FINISH
1 HOUR FIRE SEPARATION
GENERAL NOTES
RECESSED SOAP DISH-SEE DETAIL 5/A05
SHOWER CURTAIN AND ROD
10
11
1. ALL EXTERNAL BLOCK CORNERS TO HAVE BULLNOSED EDGES, SEE TYPICAL
DETAIL 2/A03.
SHOWER GRAB BAR, SEE DETAIL 5/A0512
FOLDING SHOWER SEAT, SEE DETAIL 5A0513
POR PORCELAIN FLOOR TILE VCT VINYL COMPOSITION TILE
SEE NEW CONSTRUCTION NOTE 3
EXISTINGSTAIR
EXISTINGCORRIDOR
24
00
42
60
3150
24
25
6730
26
80
WALL MOUNTED T.V (N.I.C.)
D.W.
A= 6.49m2
002
NEW
UNIVERSAL
WR
003
NEW
KITCHENETTE
A= 5.76m2
004
NEW
CALMING
RM
A=7.68m2
005
NEW
BREAKOUT
RM
A= 69.21 m2
001
NEW
MAIN ROOM
CH
AN
GE
T
AB
LE
N.I.C
.
100
140 2160
2400
65
01
10
06
50
14
0
100 140
140
14
0
C
L
C
L
46
01
56
04
60
14
01
50
01
40
4
1
3
1000
11
10
7
8
2
9
6
5
FD
FD
19
01
10
0
2150
140
REF.
N.I.C.
PDO
PDO
14
02
40
0
25
40
1100 400
3200140
140
6
A05
900x1500 CLEAR
TRANSFER
SPACE
920 X 1370 CLEAR
FLOOR SPACE
Ø
1
7
0
0
760 X
1500
CLEAR
FLOOR
SPACE
1
2
2
3
2/A
06
4/A06 1/A06
1/A07
5/A
06
2/A
06
3/A
06
5/A
06
1/A
06
VC
TE
XIS
T
POR VCT
002
00
1
004
00
5
VCTVCT
VC
TV
CT
3/A07
2/A07
4/A07
5/A
07
12
13
49
58
00
49
0
660
80
08
00
80
0
4
5/A
07
4
4
4
4
4
4
24
00
X
1
20
0 W
B
(S
EE
D
ET
AIL
3
/A
02
)
9 5
3
86 7
10
90
09
00
10
11
830
4/A
07
900
90
0
800 1000
6/A06
64
0
12 12
PDO
300
600
60
0
600
10
13
13
PDO
4
4
EXISTINGSTAIR
EXISTINGCOMPUTER
CLASSROOM
EXISTINGCORRIDOR
4
7
7
8
6
9 9 98 5
9
1 2 3
10
7
10
10
11
11
12
13 13
14
14
DEMOLITION NOTES ( INDICATED BY: )
1. COMPLETELY REMOVE EXISTING VCT FLOORING AND RCB.
2. CHIP OUT / REMOVE CONCRETE SLAB ON GRADE AT EXISTING RECESSED ELECTRICAL RECEPTACLES IN FLOOR SLAB. REFER
TO ELECTRICAL DRAWINGS FOR REMOVAL OF RECEPTACLES.
3. COMPLETELY REMOVE EXISTING SUSPENDED T-BAR CEILING GRID AND LAY IN TILE INCLUDING ALL LIGHT FIXTURES AND
MECHANICAL DIFFUSERS.
4. COMPLETELY REMOVE EXISTING DOOR & FRAME.
5. CUT BACK & REMOVE PORTION OF EXISTING CONCRETE BLOCK WALL AS REQUIRED FOR WIDER DOOR OPENING.
6. SAW CUT AND REMOVE SECTION OF CONCRETE SLAB ON GRADE TO PERMIT INSTALLATION OF NEW UNDERGROUND SERVICES.
7. COMPLETELY REMOVE EXISTING WALL MOUNTED TACKBOARD.
8. COMPLETELY REMOVE EXISTING SLOPING CHALKBOARD.
9. COMPLETELY REMOVE EXISTING MILLWORK.
10. EXISTING PERIMETER RADIATION TO REMAIN.
11. EXISTING PERIMETER RADIATION TO BE REMOVED. SEE MECHANICAL DWGS.
12. SAW CUT / REMOVE PORTION OF EXTERIOR MASONRY WALL ABOVE CEILING LINE FOR NEW WASHROOM EXHAUST DUCT /
GRILLE. SEE MECHANICAL DWGS.
13. REMOVE PORTIONS OF BULKHEAD / CEILING ABOVE LOCKERS AS REQUIRED TO PERMIT NEW MECHANICAL WORK.
14. REMOVE EXISTING SHADES.
XX
1. REMOVE AND DISPOSE OF ALL EXISTING DOORS, MILLWORK,
FITMENTS AND FINISHES INDICATED BY DASHED LINES OR AS
NOTED. GENERAL CONTRACTOR IS RESPONSIBLE FOR THE
DISPOSAL OF ALL WASTE MATERIAL DUE TO DEMOLITION,
CONSTRUCTION, OR OTHERWISE, OFF SITE.
2. PROTECT ALL EXISTING SURFACES WHICH ARE TO REMAIN.
CLEAN, REPAIR, & MAKE GOOD EXISTING WALLS AND SURFACES
DISRUPTED BY THE DEMOLITION WORK. PREPARE AND MAKE
GOOD ALL WALLS AND FLOOR SURFACES READY FOR FINISHES
AND FLOOR FINISHES.
3. IN ALL AREAS OF CONSTRUCTION WHERE EXISTING FLOOR FINISH
IS TO BE REMOVED, REMOVE ALL LAYERS OF EXISTING FLOOR
FINISH INCLUDING ALL ADHESIVES TO EXPOSE THE EXISTING
FLOOR ASSEMBLY. MAKE GOOD EXISTING SUBFLOOR IN
PREPARATION FOR INSTALLATION OF NEW FLOOR FINISH.
4. DEMOLITION DRAWINGS SHALL BE READ IN CONJUNCTION WITH
ALL OTHER ARCHITECTURAL & CONSULTANT DRAWINGS TO
UNDERSTAND FULL SCOPE OF WORK.
5. EXISTING FURNITURE/EQUIPMENT TO BE REMOVED BY OWNER
PRIOR TO RENOVATION.
DEMOLITION GENERAL NOTES
Project
Sheet Title
Scale
Drawn
Project No.
Checked
Of
Sheet No.
THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL FIELDDIMENSIONS AND SHALL NOTIFY THE ARCHITECT OF ANY SITE CONDITIONSOR FIELD DIMENSIONS WHICH MAY BE AT VARIANCE WITH THE DRAWINGS.
THIS DRAWING IS NOT TO BE SCALED.
Date Issue
No. Date Revision
COLLEGIATE LIFE SKILLS SUITE RENOVATION
SIMCOE COUNTY DISTRICT SCHOOL BOARD
Midhurst Ontario
P.N.
19042 7
mc architectsmcarch.com
Toronto Office:1881 yonge street suite 400 toronto ontario m4s 3c4phone 416 489 4646 fax 416 489 6989
Offices: TORONTO - OWEN SOUND
Owen Sound Office:201-870 3rd ave east owen sound ontario m4s 3c4phone 519 376 8210 fax 519 376 3112
COLLINGWOOD
2020-06-29 ISSUED FOR TENDER & BUILDING PERMIT
PARTIAL GROUND FLOOR- DEMOLITION AND NEW WORK
B.W.
AS NOTED A033SCALE
PARTIAL GROUND FLOOR PLAN - NEW WORK1 : 50
1
A03SCALE
PARTIAL GROUND FLOOR PLAN - DEMOLITION1 : 50
2
A03
SCALE
TYPICAL WHITEBOARD / TACKBOARD DETAILS1:5
3
A03
49 57 40
146
50
19
505
3. HEAD
19 M
AX
.
U/N
FLOOR ANCHOR CLIP
BEYOND AT BOTH JAMBS
FIN. FLOOR
DOOR
140mm MASONRY
PARTITION TO U/S OF
EXISTING STRUCTURE
SEALANT (TYPICAL)
CENTER DOOR
FRAME ON
PARTITION
DOOR
SEALANT (TYPICAL)
FILL FRAME WITH
MORTAR
MASONRY JAMB ANCHOR
DOOR
1. SILL
2. JAMB
STRUCTURAL LINTEL, REFER
TO STRUCTURAL DWGS.
49 57 40
146
50
19
19 M
AX
.
U/N
FLOOR ANCHOR CLIP
BEYOND AT BOTH JAMBS
FIN. FLOOR
DOOR
EXISTING LINTEL TO REMAIN
SEALANT (TYPICAL)
CENTER DOOR
FRAME ON
PARTITION
DOOR
1. SILL2. HEAD
EXIST. MASONRY
WALL TO REMAIN
55019
49
57
40
3. JAMB
146
EX
IS
T. M
AS
ON
RY
WA
LL T
O R
EM
AIN
SECURE HOLLOW
METAL WINDOW FRAME
TO THE EXISTING
MASONRY WALL
DOOR
13mm GYP. BD ON 92mm
STEEL CHANNEL FRAMING
GYP. BD BULKHEAD TO BE
50mm LOWER THAN THE
LOWEST T-BAR CEILING
FO
R H
EIG
HT
SE
E R
.C
.P
.
ACOUSTIC PANEL
10
0
10
05
0
ACOUSTIC PANEL
50
FO
R H
EIG
HT
SE
E R
.C
.P
.
BASE
NEW MAIN ROOM
NEW BREAKOUT ROOM
ROOM NAMEROOM
003
002
001
No.FLOOR
EAST WALLNORTH WALL
MAT'L FIN MAT'L FIN
SOUTH WALL
MAT'L FIN MAT'L
WEST WALL
FINNOTE No.
CEILING
MAT'L FIN
VCT RB PT PT PT PT
005 1
-ACT
PT
PT PT PT PT
REINSTATE EXISTING SURFACES AFFECTED BY RENOVATION WORK.1.
NOTES:
NEW KITCHENETTE VCT RB
004 PT PT PT 1, 2
1
1
1
NEW UNIVERSAL WASHROOM
NEW CALMING ROOM
POR POR
CMU
VCT RB CMU
VCT RB
CMU
EXIST.
CMU
EXIST.
CMU
EXIST.
CMU
EXIST.
GBD
PTGBD
-ACT
GBD
PT
PT
CWT CWT CWT CWT- - - -
CMU PT CMU PT--
PTCMU
EXIST.EXIST.CMU
EXIST. EXIST.CMU CMU
2. PROVIDE WALL PADDING FROM FINISHED FLOOR TO U/S OF CEILING - TYPICAL FOR ALL WALLS INCLUDING FACE OF DOOR. PROVIDE CUT OUTS FOR GLASS LIGHT IN DOOR.
FINISHEDFLOOR
VARIES, SEESCHEDULE
A
15
0
150150
90
0
VP
SEE SCHED.
SE
E S
CH
ED
UL
E
B
FINISHEDFLOOR
50 50
50
F01FINISHEDFLOOR
TYPEELEV.No.
DOORRATING
FIRE
WIDTH
DOOR
HEIGHT
SIZEMAT'L
THICK.FIN. FIN.
ELEV.TYPE
FRAME/SCREEN
VISIONPANEL
NOTENo.
DETAILNo.
MAT'LVISIONPANEL
NOTENo.
FIR
E E
XIT
HARDWARE
DOORNo.
HIN
GE
S(P
AIR
S)
SE
T
MA
ST
ER
LOC
KS
ET
KE
Y
PR
IVA
CY
PA
SS
AG
ES
ET
CLO
SE
R
PU
SH
&P
ULL
SE
T
PA
NIC
ST
OP
SF
LOO
RW
ALL
OR
HA
RD
WA
RE
TH
RE
SH
OLD
KIC
KP
LAT
E
ST
RIP
PIN
GW
EA
TH
ER
-
FLU
SH
BO
LTS
ON
INA
CTI
VE
AS
TR
AG
AL
DO
OR
NO
TE
No.
HA
RD
WA
RE
ST
OP
SO
VE
RH
EA
D
002 A 2150 45 HM PT
HA
RD
WA
RE
PTHM- 1000
001
005
004
B
B
B
1000 2150 45 HM PT
F01
PTHM -
1000 2150 45 HM PT
F01
F01
PTHM
PTHM
-
-
1 12
1000 2150 45 HM PT
1 12
GENERAL NOTES:
G1 ALL DOORS, FRAMES AND HARDWARE REQUIRED TO HAVE A FIRE PROTECTION RATING SHALL BE ULC OR WARNOCK-HERSEY LABELED.
- -
F01
-
TGL
TGL
002
001
005
004
1 12 H3- -
-
-
-
-
-
-
-
-
- -
- -
-
- -
-
-
- -
-
-
-
-
- -
-
-
-
-
-
-
-
-
-
-
HARDWARE NOTES:
H1 LOCKS SHALL BE CYLINDER TYPE U/N.H2 ALL HARDWARE FINISHES SHALL BE STAINLESS STEEL C320, OR BRUSHED CHROME WHERE APPLICABLE, U/N.H3 PROVIDE STOREROOM LOCKSET, POWER DOOR OPERATOR C/W PUSH BUTTON CONTROLS AND ELECTRIC STRIKE.
-
-
-
-
-
-
-
34 h 8/A04
5/A04
5/A04
5/A04
1 12 H4
H4 PROVIDE CLASSROOM SECURITY LOCKSET, POWER DOOR OPERATOR C/W PUSH BUTTON CONTROLS AND ELECTRIC STRIKE.
- -
LEGEND
GBBH
MASONRY ABOVE SCREEN OR OPENING
GYPSUM BOARD BULKHEAD
RETURN AIR GRILLE
SUPPLY AIR DIFFUSER
EXHAUST GRILLE
(Recessed)
TILE IN T-BAR SUSPENSION GRID
610x1220 LAY-IN ACOUSTIC
RECESSED LIGHT FIXTURE
RECESSED LIGHT FIXTURE
GBD
ACT2650
GBD2650
ACOUSTIC TILES CEILING
AT 2650 ABOVE FIN. FLOOR
GYPSUM BOARD CEILING
AT 2650 ABOVE FIN. FLOOR
UNLESS NOTED OTHERWISE
M-E=MATCH EXISTING HEIGHT
1. REFLECTED CEILING PLAN IS FOR GENERAL LAYOUT AND
CO-ORDINATION OF CEILING COMPONENTS.
REFER TO FLOOR PLANS, DETAILS AND CONSULTANTS
DRAWINGS FOR SPECIFIC INFORMATION.
2. LAY-IN ACOUSTIC TILE CENTRED IN ROOMS
3. CONTACT ARCHITECT PRIOR TO LOCATING CEILING ACCESS
PANELS IN ALL GYPSUM BOARD FINISHED CEILINGS TYP.
GYPSUM WALL BOARD- PAINTED
GENERAL NOTES
EXISTINGSTAIR
EXISTINGCORRIDOR
002
NEW
UNIVERSAL
WR
003
NEW
KITCHENETTE
004
NEW
CALMING
RM
005
NEW
BREAKOUT
RM
001
NEW
MAIN ROOM
GBD2650
GB
BH
@
2
60
0
ACT2650
ACT2650
GBD2650
ACT2650
6
A04
1220
610 610
1750 1400
1050
1050
C
L
600 600
EQ
.E
Q.
Project
Sheet Title
Scale
Drawn
Project No.
Checked
Of
Sheet No.
THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL FIELDDIMENSIONS AND SHALL NOTIFY THE ARCHITECT OF ANY SITE CONDITIONSOR FIELD DIMENSIONS WHICH MAY BE AT VARIANCE WITH THE DRAWINGS.
THIS DRAWING IS NOT TO BE SCALED.
Date Issue
No. Date Revision
COLLEGIATE LIFE SKILLS SUITE RENOVATION
SIMCOE COUNTY DISTRICT SCHOOL BOARD
Midhurst Ontario
P.N.
19042 7
mc architectsmcarch.com
Toronto Office:1881 yonge street suite 400 toronto ontario m4s 3c4phone 416 489 4646 fax 416 489 6989
Offices: TORONTO - OWEN SOUND
Owen Sound Office:201-870 3rd ave east owen sound ontario m4s 3c4phone 519 376 8210 fax 519 376 3112
COLLINGWOOD
2020-06-29 ISSUED FOR TENDER & BUILDING PERMIT
PARTIAL GROUND FLOOR RCP- NEW WORK / SCHEDULES / DETAILS
B.W.
AS NOTED A044SCALE
PARTIAL GROUND FLOOR PLAN RCP - NEW WORK1 : 50
1
A04
SCALE
ROOM FINISH SCHEDULEN.T.S.
7
A04
SCALE
DOOR AND HARDWARE SCHEDULEN.T.S.
3
A04 SCALE
DOOR ELEVATION1 : 50
2
A04
SCALE
FRAME ELEVATION1 : 50
4
A04
SCALE
GYPSUM BOARD BULKHEAD DETAIL1 : 10
6
A04
SCALE
H.M. FRAME DETAILS - MASONRY PARTITION1 : 5
5
A04
SCALE
H.M. FRAME DETAILS - EXISTING MASONRY PARTITION1 : 5
8
A04
MORTAR BED
SLOPED TO DRAIN
WATERPROOFING
MEMBRANE
CERAMIC MOSAIC TILE
SLOPE
100
MA
X.
CONCRETE SLAB
CERAMIC WALL
TILE
CONC. BLOCK
WALL
13
mm
PORCELAIN TILE
SHOWER
AREA
CURB
50
DEPRESSED
50
12
00
T
O F
LO
OR
M
AX
. (N
TS
)
IN THE EVENT OFAN EMERGENCYPUSH EMERGENCYBUTTON ANDAUDIBLE ANDVISUAL SIGNALWILL ACTIVIATE
25mm HIGH LETTERS,
5mm FONT THICKNESS
EMERGENCY
CALL BUTTON
350
315
15
450
850
1070
VERTICAL TRACK FOR SHOWER
HEAD, SHOWER HEAD TO BE
ADJUSTABLE BETWEEN 950 MIN.
AND 1500 MAX. A.F.F.
SINGLE-LEVER CONTROL FOR
WATER SUPPLY C/W THERMOSTATICALLY
CONTROLLED VALVE
RECESSED SOAP DISH
L-SHAPED STAINLESS STEEL GRAB BAR WITH
STAINLESS STEEL ESCUTCHEON PLATES
WALL MOUNTED FOLDING
SHOWER SEAT
150
900
1500mm HOSE ACCESSIBLE
FROM SEATED POSITION
900
900
95
0
FIN.
FLR
HAND DRYER
60
0
SANITARY NAPKIN
DISPOSAL BIN
C
L
C
L
C
300 MAX.
75
07
60
L-SHAPED GRAB
BAR C/W
ESCUTCHEONS
150
900 MAX.
460 MIN.
480 MAX.
60
0 M
IN
.
38 MIN. CLEAR
600mm LONG GRAB
BAR C/W
ESCUTCHEONS
38 MIN. CLEAR
84
0 M
IN
.
92
0 M
AX
.
40
0 M
IN
.
46
0 M
AX
.
L OF DISPENSER
TOP OF SEAT
NOTES:
1. THIS DETAIL IS FOR THE PURPOSE OF LOCATING
ITEMS WITHIN THE CUBICLE OR ROOM;
REFER TO DRAWINGS FOR ACTUAL WC LOCATION,
AND ACCESSORY NUMBER.
2. INSTALL COAT HOOK ON SIDE WALL,
MOUNTED 1200 mm MAX. AFF.
3. INSTALL WASHROOM SHELF MOUNTED 1000mm MAX. AFF.
4. PROVIDE BACK SUPPORT FOR WC
5. PROVIDE WOOD BLOCKING FOR GRAB BARS.
TOILET
TISSUE
DISPENSER
SUPPLIED
BY OWNER
C
L
350 M
IN
.
205
300
685
735 M
IN
.
C
L
485 MAX.
20 (TYP)
SOAP DISPENSER ON
SIDE WALL, SUPPLIED
BY OWNER
SOAP DISPENSER ON SIDE
WALL MAX. 610mm FROM
EDGE OF LAVATORY
840 M
AX
.
820 M
IN
.
950 M
AX
.
NOTE: LOCATE TOWEL DISPENSER OR HAND DRYER WITHIN 610mm FROM EDGE OF LAVATORY
SST - FRAMED FIXED
MIRROR MOUNTED ON
CENTRELINE OF
BARRIER-FREE
WALL-MOUTNED FIXTURE
CLEARANCE
LINE
1200 M
AX
.
FACE OF SIDE WALL
LEVER TYPE FAUCET HANDLES
WALL HUNG LAVATORY
FIN.
FLOOR
SIDE ELEVATION FRONT ELEVATION
AT
F
RO
NT
E
DG
E
460 MIN.
840
40
19mm DOOR, BOTTOM
AND GABLES
19mm TOP AND DOORS
13x89mm NAILER STRIPS-
TYPICAL AT TOP AND
BOTTOM
RETURN BACKSPLASH
AT WALLS TYPICAL
P.LAM ON 19mm
COUNTER TOP AND
BACKSPLASH
BACKSPLASH
BEYOND
19x89mm STRETCHER RAILS
AT FRONT AND BACK- TYPICAL
19x45mm
TOP RAIL
19mm BOTTOM, GABLES
AND DOORS
13x89mm NAILER STRIPS-
TYPICAL AT TOP AND BOTTOM
38x100mm
BASE FRAMING
38x100mm
BASE FRAMING
19mm BOTTOM
AND GABLES
19mm BOTTOM, GABLES
AND DOORS
.7 UPPER CUPBOARD-BOTTOM
SEALANT
.8 UPPER CUPBOARD - TOP
6mm BACK
RESILIENT SILENCERS
DOOR PULL
RESILIENT SILENCERS
.6 END GABLE-COUNTER TOP.5 COUNTER-FRONT EDGE.4 BACKSPLASH
.1 COUNTER BASE AT WALL .3 END GABLE-BASE.2 BASE
RB
RB
RESILIENT SILENCERS
EDGING TYP.
6mm BACK
6mm BACK
RESILIENT SILENCERS
19mm GABLE
6mm BACK
EDGING TYP.
75
10
0
10
0
40
10
0
40
40
10
20
325
40
RETURN BACKSPLASH
AT WALLS TYPICAL
P.LAM ON 19mm
COUNTER TOP AND
BACKSPLASH
19x89mm STRETCHER RAILS
AT FRONT AND BACK -TYPICAL
6mm
DRAWER BOTTOM
13mm DRAWER FRONT,
BACK AND SIDES
19x45mm TOP RAIL
19mm DRAWER
FACE PANEL
19x45mm INTERMEDIATE
TYPICAL RAIL
.9 SECTION AT DRAWER BACK .10 SECTION AT DRAWER FRONT
6mm BACK
SEALANT
SCRIBE TOP TO WALL
RESILIENT
SILENCERS
DRAWER PULL
RESILIENT
SILENCERS
19mm DOOR
10
0
40
40
10
5
.2 GABLE AT WALL
.3 PLAN AT DRAWER
5
.4 END GABLE AT FULL HEIGHT CLOSET
.5 CENTRE GABLE AT FULL HEIGHT CLOSET
20mmX40mm SOLID WOOD
STOP - TYPICAL AT JAMBS
20mmX40mm SOLID
WOOD STOPS - TYPICAL
AT JAMBS
EDGE OF COUNTER TOP
ABOVE AT END UNIT
19mm DRAWER
FACE PANEL
13mm DRAWER FRONT,
BACK AND SIDES
38mm x 38mm SOLID WOOD JAMB
WITH DADO TO ACCEPT GABLE END
SCRIBE GABLE
TO SUIT WALL
SOLID CORE
WOOD DOOR
SCRIBE GABLE
TO SUIT WALL
SOLID CORE
WOOD DOOR
19 X 38mm SPACER
SCRIBE TO WALL
19mm DRAWER FRONT
OR DOOR
38mm x 60mm
SOLID WOOD JAMB
WITH DADO TO ACCEPT
CENTRE GABLE.
13mm x 89mm
NAILER STRIPS.
13
30
19mm GABLE
19mm GABLE WALL
SEALANT
13x89mm NAILER STRIPS
6mm BACK
SURFACE OF WALL
SEALANT
13x89mm NAILER STRIPS
6mm BACK
19mm CENTRE GABLE.
6mm BACK
SURFACE OF WALL
.1 JAMB AT WALL
TYPICAL MILLWORK SECTION DETAILS
TYPICAL MILLWORK PLAN DETAILS
Project
Sheet Title
Scale
Drawn
Project No.
Checked
Of
Sheet No.
THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL FIELDDIMENSIONS AND SHALL NOTIFY THE ARCHITECT OF ANY SITE CONDITIONSOR FIELD DIMENSIONS WHICH MAY BE AT VARIANCE WITH THE DRAWINGS.
THIS DRAWING IS NOT TO BE SCALED.
Date Issue
No. Date Revision
COLLEGIATE LIFE SKILLS SUITE RENOVATION
SIMCOE COUNTY DISTRICT SCHOOL BOARD
Midhurst Ontario
P.N.
19042 7
mc architectsmcarch.com
Toronto Office:1881 yonge street suite 400 toronto ontario m4s 3c4phone 416 489 4646 fax 416 489 6989
Offices: TORONTO - OWEN SOUND
Owen Sound Office:201-870 3rd ave east owen sound ontario m4s 3c4phone 519 376 8210 fax 519 376 3112
COLLINGWOOD
2020-06-29 ISSUED FOR TENDER & BUILDING PERMIT
DETAILS
B.W.
AS NOTED A055SCALE
TYPICAL MILLWORK DETAILS1 : 5
1
A05SCALE
BARRIER-FREE LAVATORY & MIRROR ELEVATION1 : 20
2
A05SCALE
BARRIER-FREE WASHROOM LAYOUT1 : 20
3
A05
SCALE
WASHROOM ACCESSORIES ELEVATIONS1 : 20
4
A05SCALE
BARRIER-FREE SHOWER STALL1 : 20
5
A05
SCALE
BARRIER-FREE SHOWER THRESHOLD1 : 5
6
A05SCALE
EMERGENCY CALL BUTTON AND SIGN1 : 5
7
A05
FRONT ELEVATIONSECTION
325
25
20
91
58
00
600
25
10
08
15
10
0
40
640
40
10
CUPBOARD LOCK
COUNTER
TOP AT
OPEN END
CONTINUOUS 19mm COUNTER
TOP AND BACKSPLASH
SCRIBE TOP
TO WALL
22
00
CUPBOARD LOCK
48
5
13x89mm NAILER STRIPS-
TYPICAL AT TOP AND BOTTOM
RECESSED PILASTER STRIPS
(TYPICAL C/W SHELF CLIPS)
PROVIDE TWO 19mm
ADJUSTABLE SHELVES PER UNIT
19x89mm STRETCHER RAILS
AT FRONT AND BACK - TYPICAL
RECESSED PILASTER STRIPS -
TYPICAL C/W SHELF CLIPS
PROVIDE TWO 19mm
ADJUSTABLE SHELVES
PER UNIT
19mm TOP, BOTTOM, GABLES
AND DOORS
CONTINUOUS
13x89mm NAILER STRIPS-
TYPICAL AT TOP AND BOTTOM
DOOR PULL
6mm BACK
SEALANT
19x45mm TOP RAIL
DOOR PULL
19mm BOTTOM, GABLES AND
DOORS
38x100mm BASE FRAMING
CONTINUOUS RB
6mm BACK
75
NOTE: REFER TO DETAILS 1/A05 FOR TYPICAL MILLWORK PLAN AND SECTION DETAILS
490 OR 495
325
2520
80
0
20
600
25
40
640
40
10
75
550
15
0
DRAWER
LOCK
SCRIBE TOP
TO WALL
CONTINUOUS
13x89mm NAILER STRIPS-
TYPICAL AT TOP AND BOTTOM
19mm TOP, BOTTOM, GABLES
AND DOORS
PROVIDE TWO 19mm ADJUSTABLE
SHELVES PER UNIT
RECESSED PILASTER STRIPS-TYPICAL
C/W SHELF CLIPS
CONTINUOUS 19mm COUNTER TOP
AND BACKSPLASH
19x89mm STRETCHER RAILS
AT FRONT AND BACK - TYPICAL
PROVIDE ONE 19mm ADJUSTABLE
SHELF - PER UNIT
RECESSED PILASTER STRIPS - TYPICAL
C/W SHELF CLIPS
13x89mm NAILER STRIPS-
TYPICAL AT TOP AND BOTTOM
TYPICAL DRAWER CONSTRUCTION:
-19mm FACE PANEL
-13mm FRONT, SIDES AND BACK
-6mm BOTTOM
6mm BACK
DOOR PULL
19x45mm TOP RAIL
DRAWER PULL
DRAWER SLIDES
DOOR PULL
19mm BOTTOM, GABLES AND DOORS
6mm BACK
CONTINUOUS RB
38x100mm BASE FRAMING
SEALANT
SECTIONFRONT ELEVATION
COUNTER TOP AT OPEN END
CUPBOARD LOCK
DOOR CATCH
CUPBOARD LOCK
DOOR
CATCH
800
48
5
22
00
NOTE: REFER TO DETAILS 1/A05 FOR TYPICAL MILLWORK PLAN AND SECTION DETAILS
80
03
85
81
5
22
00
80
04
85
91
5
COUNTER TOP
RUBBER BASE
616
40
19mm GABLE BEYOND
19x89mm STRETCHER RAILS AT
FRONT & BACK (TYP.)
CONTINUOUS 19mm
COUNTER TOP &
BACKSPLASH
SCRIBE TOP
TO WALL
SEALANT
40
635
FRONT ELEVATION SECTION
DOOR PULL
6mm BACK
RECESSED PILASTER STRIPS
(TYP.) C/W SHELF CLIPS
PROVIDE TWO 19mm ADJUSTABLE
SHELVES PER UNIT
19mm BOTTOM, GABLE & DOORS
CONTINUOUS 13x89mm NAILER
STRIPS (TYP. AT TOP & BOTTOM)
2 CLIP ANGLES TO SECURE
GABLE TO FLOOR - MORTISE
GABLE TO ACCEPT CLIP ANGLES
NOTE:
CO-ORDINATE WITH MECH./ELEC.
FOR INSTALLATION OF SERVICES
TO DISHWASHER LOCATION.
OUTLINE OF DISHWASHER N.I.C.
660
10
0
OUTLET
ELECTRICAL
N.I.C.
DISHWASHER
622
10
01
00
325
25
20
600
10
08
15
10
0
40
640
40
10
20
22
00
91
58
00
75
CONTINUOUS 19mm COUNTER TOP
AND BACKSPLASH
DOOR CATCH
COUNTER
TOP AT
OPEN END
CUPBOARD
LOCK
OUTLINE OF
DOUBLE BOWL
SINK
OUTLINE OF
SINGLE BOWL
SINK
CUPBOARD
LOCK
CONTINUOUS
13x89mm NAILER STRIPS-
TYPICAL AT TOP, MIDDLE, AND
BOTTOM
19mm TOP, BOTTOM,
GABLES, AND DOORS
PROVIDE TWO 19mm ADJUSTABLE
SHELVES PER UNIT
RECESSED PILASTER STRIPS
(TYPICAL C/W SHELF CLIPS)
19x38mm STRETCHER RAIL AT
FRONT AND 19x89mm STRETCHER
RAIL AT BACK
13x89mm NAILER STRIPS -
TYPICAL AT TOP AND BOTTOM
6mm BACK
DOOR PULL
SINK
19mm BOTTOM, GABLES AND DOORS
6mm BACK
19x190mm TOP RAIL
DOOR PULL
38x100mm BASE FRAMING
CONTINUOUS RB
SECTION FRONT ELEVATION
800
48
5
DOOR CATCH
NOTE: REFER TO DETAILS 1/A05 FOR TYPICAL MILLWORK PLAN AND SECTION DETAILS NOTE: REFER TO DETAILS 1/A05 FOR TYPICAL MILLWORK PLAN AND SECTION DETAILS
20
325
80
03
85
81
5
10
01
00
91
5
PROVIDE TWO 19mm ADJUSTABLE
SHELVES PER UNIT
DOOR PULL
19x45mm TOP RAIL
19mm BOTTOM, GABLES AND DOORS
25
20
80
0
20
600
25
10
01
00
40
640
40
10
6mm BACK
TYPICAL AT TOP AND BOTTOM
13x89mm NAILER STRIPS-
CONTINUOUS RB
75
38x100mm BASE FRAMING
TYPICAL AT TOP AND BOTTOM
13x89mm NAILER STRIPS-
CONTINUOUS
19mm TOP, BOTTOM, GABLES
AND DOORS
PROVIDE TWO 19mm ADJUSTABLE
SHELVES PER UNIT
DOOR PULL
6mm BACK
DOOR CATCH
DOOR CATCH
19x89mm STRETCHER RAILS
AT FRONT AND BACK - TYPICAL
SEALANT
CUPBOARD
LOCK
COUNTER TOP
AT OPEN END
CONTINUOUS 19mm COUNTER
TOP AND BACKSPLASHSCRIBE TOP
TO WALL
22
00
CUPBOARD
LOCK
48
59
15
81
5
325
SECTION FRONT ELEVATION
RECESSED PILASTER
STRIPS-TYPICAL C/W SHELF CLIPS
800
RECESSED PILASTER STRIPS
-TYPICAL C/W SHELF CLIPS
PROVIDE TWO 19mm ADJUSTABLE
SHELVES PER UNIT
DOOR PULL
19x45mm TOP RAIL
19mm BOTTOM, GABLES AND DOORS
25
20
80
0
20
600
25
10
01
00
40
640
40
10
6mm BACK
TYPICAL AT TOP AND BOTTOM
13x89mm NAILER STRIPS-
CONTINUOUS RB
75
38x100mm BASE FRAMING
TYPICAL AT TOP AND BOTTOM
13x89mm NAILER STRIPS-
CONTINUOUS
19mm TOP, BOTTOM, GABLES
AND DOORS
PROVIDE TWO 19mm ADJUSTABLE
SHELVES PER UNIT
DOOR PULL
6mm BACK
DOOR CATCH
19x89mm STRETCHER RAILS
AT FRONT AND BACK - TYPICAL
SEALANT
CUPBOARD
LOCK
COUNTER TOP
AT OPEN END
CONTINUOUS 19mm COUNTER
TOP AND BACKSPLASHSCRIBE TOP
TO WALL
22
00
CUPBOARD
LOCK
48
59
15
81
5
325
SECTION FRONT ELEVATION
RECESSED PILASTER
STRIPS-TYPICAL C/W SHELF CLIPS
515
RECESSED PILASTER STRIPS
-TYPICAL C/W SHELF CLIPS
12mm FILLER PANEL
FINISHED CEILING
SCALE
COUNTER-DRAWERS & HINGED DOORS / CUPBOARDS-HINGED DOORS1 : 20
1
A06SCALE
COUNTER - HINGED DOORS / CUPBOARD - HINGED DOORS1 : 20
2
A06SCALE
COUNTER-DRAWERS & HINGED DOORS / CUPBOARDS-HINGED DOORS1 : 20
3
A06
SCALE
COUNTER AT DISHWASHER / CUPBOARDS - HINGED DOORS1 : 20
4
A06SCALE
COUNTER-HINGED DOORS & SINK / CUPBOARDS-HINGED DOORS1 : 20
5
A06SCALE
COUNTER-DRAWERS & HINGED DOORS / CUPBOARDS-HINGED DOORS1 : 20
6
A06
WALL
BEYOND
CUPBOARD
LOCK
660
FILLER PANEL
FINISH TO MATCH
CABINETS
12mm FILLER PANEL
FINISHED CEILING
FILLER PANEL FINISH
TO MATCH CABINETS
12mm FILLER PANEL
FINISHED CEILING
FILLER PANEL
FINISH TO MATCH
CABINETS
12mm FILLER PANEL
FINISHED CEILING
FILLER PANEL FINISH
TO MATCH CABINETS
12mm FILLER PANEL
FINISHED CEILING
FILLER PANEL
FINISH TO MATCH
CABINETS
12mm FILLER PANEL
FINISHED CEILING
FILLER PANEL FINISH
TO MATCH CABINETS
190 325
830
Project
Sheet Title
Scale
Drawn
Project No.
Checked
Of
Sheet No.
THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL FIELDDIMENSIONS AND SHALL NOTIFY THE ARCHITECT OF ANY SITE CONDITIONSOR FIELD DIMENSIONS WHICH MAY BE AT VARIANCE WITH THE DRAWINGS.
THIS DRAWING IS NOT TO BE SCALED.
Date Issue
No. Date Revision
COLLEGIATE LIFE SKILLS SUITE RENOVATION
SIMCOE COUNTY DISTRICT SCHOOL BOARD
Midhurst Ontario
P.N.
19042 7
mc architectsmcarch.com
Toronto Office:1881 yonge street suite 400 toronto ontario m4s 3c4phone 416 489 4646 fax 416 489 6989
Offices: TORONTO - OWEN SOUND
Owen Sound Office:201-870 3rd ave east owen sound ontario m4s 3c4phone 519 376 8210 fax 519 376 3112
COLLINGWOOD
2020-06-29 ISSUED FOR TENDER & BUILDING PERMIT
DETAILS
B.W.
1 : 20 A066
EXPANSION CLEARANCE ON
ALL SIDES OF FIRE DAMPER
SHALL BE 12mm MAXIMUM
RETAINING ANGLES
FIRE DAMPER ASSEMBLY
MECH. DUCT
METAL COLLAR
EXISTING CMU PARTITION
SECTION 1FRONT ELEVATION
300
75
SIDE ELEVATION
DOUBLE GABLE
BETWEEN
ADJACENT UNITS
PLASTIC LAMINATE ON
19mm TOP CONTINUOUS
AT ADJACENT UNITS
PROVIDE ONE 19mm
ADJUSTABLE SHELF
PER UNIT
19mm GABLES
100mm CONTINUOUS METAL FOOT GRILLE,
REFER TO MECHANICAL DWGS.
WALL
FINISHED
FLOOR LEVEL
1
900
225
90
0
14
0
19mm TOP AND BOTTOM
38x140mm BASE FRAMING
13x89mm NAILER
STRIPS TYPICAL AT
TOP, BOTTOM AND
MID-HEIGHT
19mm TOP WITH PVC EDGES
(TYP.) CONTINUOUS METAL
SILL GRILLE; REFER TO SPEC
RECESSED PILASTER
STRIPS C/W SHELF
CLIPS
EXISTING
BASE HEATER
13x89mm NAILER STRIPS
TYPICAL AT TOP, BOTTOM
AND MID-HEIGHT
RECESSED PILASTER
STRIPS C/W SHELF CUPS
900
300 TYP.
22
00
10
0
75
75
WALL
19mm TOP
6mm BACK
6-19mm ADJUSTABLE SHELVES
19mm GABLES
19mm BOTTOM
38x100mm BASE FRAMING
CONTINUOUS RB AT ADJACENT UNITS
RB
SECTION 1FRONT ELEVATION SIDE ELEVATION
1
REFER TO FLOOR PLAN
FOR SPECIFIC DIMENSION
NOTE: REFER TO DETAILS 1/A05 FOR TYPICAL MILLWORK PLAN AND SECTION DETAILS
SCALE
HIGH OPEN SHELVING1 : 20
4
A07SCALE
OPEN SHELVES1 : 20
5
A07
FILLER PANEL FINISH
TO MATCH CABINETS
12mm FILLER
PANEL
FINISHED
CEILING
FILLER PANEL FINISH
TO MATCH CABINETS
125
PROVIDE INTERIOR
SOLID WOOD
CORNER BLOCKING
AT FLUSH BOLT
LOCATIONS - TYP.
FLUSH BOLT
TOP + BOTTOM
AT INSIDE
C/W ANGLE
STOPS
RESILIENT BASE CONT.
AT ADJACENT UNITS
19mm GABLES, TOP
AND BOTTOM
35 THICK SOLID
CORE WOOD DOORS
RECESSED
PILASTER STRIPS
C/W SHELF CLIPS
ADJUSTABLE 19mm
SHELVES,
NUMBER OF SHELVES
AS SHOWN ON ROOM
ELEVATIONS
WALL
BLOCKING
LOCKSET
LOCKSET
6mm BACK
ON FURRING
510
22
00
10
0
10
00
38mm x 38mm
SOLID WOOD JAMB
WITH DADO TO
ACCEPT GABLE END
1
125
SECTION 1FRONT ELEVATION SIDE ELEVATION
NOTE: REFER TO DETAILS 1/A05 FOR TYPICAL MILLWORK PLAN AND SECTION DETAILS
22
00
21
00
11
00
10
0
125
1050
700350
20
02
80
750
25
19mm
FIXED SHELF
FOUR 19mm
ADJUSTABLE
SHELVES
COAT ROD C/W
ROD PLANGES
RECESSED PILASTER
STRIPS-TYPICAL
C/W SHELF CLIPS
13x89mm
NAILER STRIPS-
STRIPS TYPICAL
AT TOP, BOTTOM
AND MID-HEIGHT
OUTLINE OF
ADJACENT COUNTER
35mm THICK SOLID
CORE WOOD DOORS
19mm TOP, GABLES
AND BOTTOM
38x100mm
BASE FRAMING
CONTINUOUS RCB
TOP OF
ROD
LOCKSETS
6mm BACK
21
SECTION 1FRONT ELEVATIONSECTION 2
NOTE: REFER TO DETAILS 1/A05 FOR TYPICAL MILLWORK PLAN AND SECTION DETAILS
WALL
640
SECTIONFRONT ELEVATION
GABLE
FULL HEIGHT
DOOR
CUPBOARD
RCB
17
00
50
0
22
00
PULL
LOCK
DOOR CATCH
500
1000
1
13x89mm NAILER
STRIPS-TYPICAL AT TOP
AND BOTTOM
19mm ADJUSTABLE
SHELF
19mm TOP, BOTTOM,
GABLES AND DOORS
RECESSED PILASTER
STRIPS C/W SHELF
CLIPS-TYPICAL
FULL HEIGHT GABLE
BOTH SIDES
OUTLINE OF
REFRIGERATOR
N.I.C.
NOTE: REFER TO DETAILS 1/A05 FOR TYPICAL MILLWORK PLAN AND SECTION DETAILS
SCALE
CUPBOARD AT REFRIGERATOR1 : 20
1
A07SCALE
STORAGE CLOSET1 : 20
2
A07SCALE
TEACHER'S CUPBOARD1 : 20
3
A07
12mm FILLER PANEL
FINISHED CEILING
FILLER PANEL FINISH
TO MATCH CABINETS
190 325
FILLER PANEL FINISH
TO MATCH CABINETS
FILLER PANEL FINISH
TO MATCH CABINETS
± 900
TO BE CONFIRMED ON SITE
FILLER PANEL FINISH TO
MATCH CABINETS
12mm FILLER PANEL
FINISHED CEILING
12mm FILLER PANEL
FINISHED CEILING
12mm FILLER PANEL
FINISHED CEILING
SOLID WOOD
38
38mm PIPE SPACE
38mm
PIPE
SPACE
38mm PIPE SPACE
38
Project
Sheet Title
Scale
Drawn
Project No.
Checked
Of
Sheet No.
THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL FIELDDIMENSIONS AND SHALL NOTIFY THE ARCHITECT OF ANY SITE CONDITIONSOR FIELD DIMENSIONS WHICH MAY BE AT VARIANCE WITH THE DRAWINGS.
THIS DRAWING IS NOT TO BE SCALED.
Date Issue
No. Date Revision
COLLEGIATE LIFE SKILLS SUITE RENOVATION
SIMCOE COUNTY DISTRICT SCHOOL BOARD
Midhurst Ontario
P.N.
19042 7
mc architectsmcarch.com
Toronto Office:1881 yonge street suite 400 toronto ontario m4s 3c4phone 416 489 4646 fax 416 489 6989
Offices: TORONTO - OWEN SOUND
Owen Sound Office:201-870 3rd ave east owen sound ontario m4s 3c4phone 519 376 8210 fax 519 376 3112
COLLINGWOOD
2020-06-29 ISSUED FOR TENDER & BUILDING PERMIT
DETAILS
B.W.
1 : 20 A077
SCALE
FIRE DAMPER AT EXISTING MASONRY PARTITION1 : 5
6
A07