Coal combustion testing. We test real flow of coal to the burners in power plants. Measurements can be used to adjust burning to reduce emissions, damage to boiler parts, and to increase the efficiency of fuel use.

TRANSCRIPT

Page 1: Coal Combustion Testing

www.scfingenieria.com

COAL COMBUSTION BASELINE

TESTING

www.scfingenieria.com

Page 2: Coal Combustion Testing

www.scfingenieria.com

MEASURING PRIMARY AIR FLOW 1

EQUIPMENT

We use state of the art Dirty Air Pitot with a hand held recorder that averages readings providing very accurate measurement.

PROCEDURE

If the ports are not installed, we provide the installation using 1½”, full port valves. These ports can be used for air flow as well as Coal flow measurements.

Balancing air flows to all burners in a Coal Fired Boiler is the best way to improve combustion with minimum investment.

Page 3: Coal Combustion Testing

www.scfingenieria.com

MEASURING COAL FLOW 2

Is the Manufacturer of the PFS-A-SL AUTOMATIC PULVERIZED FUEL SAMPLER. This PLC controlled testing assures isokinetic flow testing with in-site weighing and automatic coal flow calculation .

A two man team is used to obtain the coal samples. One supervises the probe, while the other enters data on the PLC and runs the test.

M&W ASKETEKNIK

With a multiple nozzle sampler and a computer controlled electric actuator we provide testing according to ISO-9931.

Page 4: Coal Combustion Testing

www.scfingenieria.com

VERIFYING SECONDARY AIR FLOWS 3

PROCEDURE

This highly accurate anemometer provides velocity readings with an accuracy of ± 3 % which allows for very clear determination of flow variations around the burner secondary air register. By graphing the velocities at 24 points it becomes clear where disturbances are present.

EXPERIENCE

We have provided burner secondary air flow measurements, finding flow distortions caused by uneven air distribution within the air box.

EQUIPMENT

TYPICAL COAL BURNER

Secondary Air

VELOCITY PROFILE

Anemometer

Page 5: Coal Combustion Testing

www.scfingenieria.com

GATHERING EMISSIONS 4

We design manufacture and install the necessary test ports to get a complete traverse grid across the duct. This multiple point sampling allows for a very precise measurement of the emissions generated by each burner.

RESULTS

The graph to the left represents the variations of NOx across a duct with a nine point sampling grid. It is very evident that one point sampling would NOT have being representative of the NOx levels present in most of the duct.

EQUIPMENT

We use the Testo 350-S which allows simultaneous in-site monitory of NOx, CO, O2 and CO2 .

NOx [PPM] - 100% LOAD

622

759755

698

760

801

716

751

758

600

620

640

660

680

700

720

740

760

780

800

820

1 2 3

NO

x [

PP

M]

Sampling points

LEVEL A

LEVEL B

LEVEL C

Page 6: Coal Combustion Testing

www.scfingenieria.com

CONTACTS USA Miguel Gonzalez, (312) - 965 63 14

Email: [email protected] Jaime Gonzalez, (305) - 359 59 63

Email: [email protected]

CONTACTS COLOMBIA Jaime Gonzalez (+57) 310 688 41 36

OUR MISION

To provide efficiency improvement solutions to Coal Fired Power Plants in Central and South America, incorporating well proven

Sate of the Art technologies.

PRODUCTS

Coal burner upgrades to reduce NOx. Classifier upgrades to improve fineness. Venturi flowmeter to measure primary air. New classifiers with state of the art technology. Emissions monitoring equipment. Continue furnace video monitoring. Infrared FEGT monitoring.

SERVICES

Combustion baseline testing. Primary air flow measurement for CFD Modeling of Burners and OFA. Coal pipes flow measurement for classifier upgrades and wind box flow balancing. Sampling gas emissions in coal fire power plants. Seminars in Spanish, on all the products and services offered by SCF.