cm smart basic meters/ transducers/dc ... - power …

34
SMART BASIC METERS/ TRANSDUCERS/DC ENERGY BASIC BASIC PARAMETERS MEASURED PRECISELY! Intertek 4007051 CM Contact for certification details Ammeter | Voltmeter | VAF Meter | Hz Meter | Frequency Meter | DC Meter | RPM & MPM www.powercorporation.in

Upload: others

Post on 09-May-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

SMART BASIC METERS/

TRANSDUCERS/DC ENERGY

BASIC

www.elmeasure.com

BASIC PARAMETERS

MEASURED PRECISELY!

Intertek4007051

CM

Contact for certification details

Ammeter | Voltmeter | VAF Meter | Hz Meter | Frequency Meter | DC Meter | RPM & MPM

www.powercorporation.in

Page 2: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

Common Features :

True RMS.

Four digit resolution with auto scaling.

Field programmable Star (Wye) or Delta or Single

Phase configuration.

Average & Phase wise information.

Additional Features:

Universal auxiliary input 80 - 300V AC

(Optional: 40-300V DC, 80-300V AC/DC).

Auto-scrolling.

Available in single row Dinrail version (Alpha+D

VAF, Alpha+D V/3V, Alpha+D A/3A, Alpha+D Hz).

Minimum order quantity apply.

Optional direct measurement upto 20A.

60A or 100A max. using Hanging CT.

Available in 0.8 inch display (4 digit) - optional

(for Alpha+ series only). Minimum order quantity

apply.

Optional Features :

2 digital output programmable for threshold upto

6 parameters (Under/Over).

Programmable tripping time upto 180 secs. with

Hysteresis of 1%.

Analog transducer output 0-20mA / 4-20mA or 0-

1V, Accuracy of 1% FS (Alpha+ only).

Optically isolated RS 485 / RS 232 serial interface

(Alpha+ only).

Displays more than 13 basic parameters i.e., VLL,

VLN, A (Average & Phase wise), F, ON Hours.

Programmable Relay Output (upto 2) {VLL, A, F

(under, over)}.

Displays Line to Line Voltage -Average and phase

wise, Amps - Average and phase wise & Frequency

(External selector switch to be used for µAlpha+

VAF).

Field programmable PT and CT primary and

secondary.

Optional programmable relay output (upto 2) for

any threshold VLL avg, A, Hz (under or over).

Optional transducer output

(0 to 20mA / 4 to 20mA or 0 to 1V DC)

for average VLL, VLN, Amps and F

(for Alpha+ series only) Accuracy 1% FS.

OMEGA 1300

Displays Amps for Alpha+ A and Amps (Avg & PW)

for Alpha+ 3A.

Field programmable CT primary and secondary.

Models: Alpha+ 3A & µAlpha+ 3A (3 Phase); Alpha+

A & µAlpha+ A (single phase).

Optional programmable relay output (upto 2) for

threshold Amp (under or over).

Optional transducer output (0 to 20mA / 4 to 20mA

or 0 to 1V DC) for average Amps (for Alpha+ series

only) Accuracy 1% of FS.

+ + ALPHA VAF/3VAF, µA VAF

+ +ALPHA / µA Hz

Displays wider range of frequency 40 - 70 Hz.

Higher accuracy class 0.2.

Optional programmable relay output (upto 2) for

threshold Hz (under or over).

Optional transducer output (0 to 20mA / 4 to 20mA

or 0 to 1V DC) for Hz(Range 45 to 65Hz) (for Alpha+

series only)

Accuracy 1% of FS

Displays VLL, VLN (Avg & PW), F, for Alpha+ 3V

& µA+ 3V. VLL for Alpha+ V & µA+ V

Field programmable PT primary and

secondary.

Models: Alpha+ 3V & µAlpha+ 3V (3 phase

measurement); Alpha+ V & µAlpha+ V (Single

Phase).

Optional programmable Relay output (upto 2)

for any threshold VLL, Hz (under or over) for

A+3V & only VLN (under or over ) for A+ V.

Optional transducer output (0 to 20mA / 4 to

20mA or 0 to 1V DC) for Average VLL, VLN and

F (for Alpha+ series only) Accuracy 1% of FS.

DC Vin - 75mV or 100mV or 10V or 100V or

500V.

0-20 mA / 4-20 mA input options. 4 digit

resolution for ADC.

DC auxiliary from 80-300V option available for

Alpha+ and Dinrail version.

Field programmable full scale or offset value.

DC Vin - 75mV or 100mV or 10V or 100V or

500V.

0-20 mA / 4-20 mA input options. 4 digit

resolution for RPM.

DC auxiliary supply option of 40 to 300V

available.

Field programmable full scale or offset value.

+ +ALPHA / µA 3V/V

+ +ALPHA / µA ADC/VDC

+ +ALPHA / µA RPM/MPM

+ +ALPHA / µA 3A/A

AMMETER VOLT METER

VAF METER

DC METER

Hz METERRPM/MPM METER

VAF METER

Page 3: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

Technical Specification :

ECO Friendly Lead Free 18 Months Warranty

Transducer Output Programmable :

Note: Additional error of 0.05% of full scale, for meter input current below 500mA

ALPHA+, µA+ & OMEGA

Accuracy:

Sensing/Measurement:

Input voltage:

A

Transducer

Models

Alpha+ 3VAF

Sl

No

1

Any One Output

Programmable

Output Range

Options

V A Hz W VA PF

Alpha+ 3V2

Alpha+ 3A3

Alpha+ Hz4

LG+ 51105

V A Hz

V Hz

Hz

V A Hz W VA PF

0-20mA / 4-20mA

0-1V DC

0-20mA / 4-20mA

0-1V DC

0-20mA / 4-20mA

0-1V DC

0-20mA / 4-20mA

0-1V DC

0-5V DC

0-10V DC

0-20mA / 4-20mA

0-1V DC

A

TRANSDUCER OUTPUT

E l M e a s u r e t r a n s d u c e r s a r e

programmable transducers (cum display),

which converts various applicable

electrical parameters like voltage, current,

frequency, active power, apparent power,

power factor into DC current 0-20mA or 4-

20mA (Programmable) or voltage 0-1V DC

output.

Applications are various: electrical,

chemical, thermal power plants, etc., to

monitor processed data either locally or

remotely using scada system by

ElMeasure or the third party.

Accuracy : Class 1.0FS

Maximum overload: 120% (Equivalent of

24mA)

Number of output: One (0 to 20mA / 4

to 20mA or 0-1V DC)

Features & Benefits :

Programmable primary / secondary voltage or

current making wider range of operations

- Stocking becomes simple

Programmable transducer output either 0-20mA

or 4-20mA. (Maximum load resistance: 75ohms.)

0-1V DC optional

DC current signal or DC voltage signal directly

proportional to the change of input.

Fully protected against open and short circuited

output.

OM 1300

OM1310

ALPHA+ 3VAF

ALPHA+ VAF µALPHA+ VAF

ALPHA+ 3A µALPHA+ 3A

ALPHA+ 3V µALPHA+ 3V

ALPHA+ A µALPHA+ A

ALPHA+ V µALPHA+ V

ALPHA+ ADC µALPHA+ ADC

ALPHA+ VDC µALPHA+ VDC

ALPHA+ Hz µALPHA+ Hz

ALPHA+ RPM µALPHA+ RPM

96×96×50mm 96×48×45mm

* Dinrail available as per minimum order quantity basis.

VLL, VLN, AMP, Hz, ON Hrs.

VLL, VLN, AMP, Hz,PF, ON Hrs, Hi Amps,RPM.

VLL, VLN, AMP, Hz

VLN, AMP, Hz (Single Phase)

AMP-Avg, AR, AY, AB

VLL, VLN, Avg & Phase wise, Hz

AMP A

VOLT V

AMP DC

VOLTS DC

Frequency (Hz)

RPM

Transducer Parameters

Product Selection :

Dinrail* (90 × 90 × 50mm)

Note : DC measurement Accuracy Class 1.0FS, Class 0.5FS (optional)

In Dinrall version other than RS458, no other option is possible

Specification Description

Class 1 Default ,Class 0.5, 0.5S as per IEC 62053-22as per IEC 62053-21

True RMS, 1 Sec update time.

4 Voltage inputs (VR, VY, VB, VN); Programmable 110 or 415V LL Nominal

(Range 80-550V LL); Primary Programmable up to 999 kV.

Burden: 0.2VA Max. per phase

Current inputs (AR, AY, AB) 50mA - 6A (Field configurable 1A or 5A).

Primary Programmable up to 99 kA.

Overload: 10A max continuous, 50A max for 3 Sec

Burden: 0.2VA Max. per phase.

80 - 300V AC for Omega 80-300V AC/DC, 40-70Hz

Burden: 4VA Max

4digits display with 14 mm height for Alpha Plus, 10 mm height for OMEGA

series, µAlpha Plus series & DinRail

RS485 serial channel connection, Industry standard Modbus RTU protocol

(RS232 optional). Zigbee communication.

Baud rate: 4800 bps to 19200 bps. (Preferred 9600 bps)

Isolation: 2000 Volts AC isolation for 1 minute between communication and

other circuits.

Unpacked: 300 gms, Packed: 400 gms

Input Current

Display:

Communication:

Weight:

Aux-Supply(Control Power):

Page 4: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters

| Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input

Output | Transducers | Converters

Sales Offices: BANGALORE | CHENNAI | COIMBATORE | MUMBAI | DELHI | HYDERABAD | USA | UAE

HO & Unit-I:

Plot No.: 47-P, Hardware Park, KIADB,

Huvinayakanahalli, Jala Hobli, Yelahanka Taluk,

Bengaluru - 562149 Karnataka INDIA.

E: [email protected]

Unit-II:

Goutham Garden, No. 4, Veerapandi,

Coimbatore - 641019 Tamilnadu INDIA

T: 0422 2697200 TF: 0244 2695200

E: [email protected]

Unit-III:

#764, 4th Phase, 707, Yelahanka New Town,

Bengaluru - 560 064 Karnataka INDIA

T: +91 80 28461744

E: [email protected]

ELMEASURE INDIA PRIVATE LIMITED

Mechanical Specification:

Safety: Designed to meet protection class III, pollution degree 2.

Protection against shock by double insulation.

Clearance and creepage meets as per UL 61010 safety standard.

Finger touch proof terminals to voltage and current connections

Environment:

Operating temperature -10°C to +55°C (14°F to 131°F)

Storage temperature -25°C to +70°C (-13°F to 158°F)

Humidity 5% to 95% non condensing.

Protection index IP 51 (IP 54 front option).

Recommended wire gauge 12 to 14 SWG.

Safety and Environmental Specification

Applicable Standards : Dimension Bezel:

96 x 96 mm (Depth 50mm behind Bezel)

96 × 48 mm (Depth 45mm behind Bezel)

Panel Cutout:+2 +290 x 90 mm-0 -0 +2 +290 x 42 mm-0 -0

PC

/AP

O/V

9/1

01

7

DIN 40050

EN 60529

Degrees of protection provided by enclosure for electrical

equipment against ingress of solid foreign objects.

DIN /

IEC 688-1

Electrical measuring transducers for converting AC electrical

quantities into DC electrical quantities.

IS 12784 Electrical measuring transducers for converting AC electrical

quantities into DC electrical quantities.

Additional features for EDC 1100

Displays V, 1 channel current, 1 channel Watt and

1 channel energy in the bright single row 6 digits.

Optional RS485 communication.

Optional single digital output with the programmable delay.

Additional features for EDC 4100

Displays V, 4 channels Current, 4 channel Watts and energy in

the bright single row 6 digits.

Optional RS485 communication.

Optional single digital output with the programmable delay.

Additional features for EDC 4400

Displays V, 4 channels Current, Watts and Energy.

Optional Load Hours (LH) and Amps hours (Ah).

Optional RS485 communication.

Optional two digital output with the programmable delay.

Additional features for EDC 4100D

LCD display, 7 digit, Din rail version only

Hall effect CT (100A) Option

ECO Friendly Lead Free 18 Months Warranty

Technical Specification :

Class 1.0 FS, Class 0.5 FS (optional)

4Row 6Digits for EDC4400, 1Row 6Digits for EDC4100 and

EDC1100.

One Input Voltage (48VDC Factory Default). Varieties of

range in Voltage like 48VDC, 100VDC, 150VDC,

300VDC,600VDC, 800VDC (factory settable). Primary

Programmable range: 0.100 to 999.9kV .

45 - 65 Hz

One/ Four Input Current (50mV, 75mV Shunt type).

Individually Programmable primary current. Range: 0.100

999.9k .

80 - 300V AC/DC, 40-70Hz

Burden: 4VA Nominal.

Rs485 interface Industry Standard Modbus RTU protocol

(RS232 optional).

4800 bps to 19200 bps. (Preferred 9600 bps).

2000 volts AC isolation for 1 minute between

communication and other circuits.

(Approx): Unpacked - 300 gms, Shipping - 400 gms.o o o o-10 C to +55 C (14 F to 131 F).o o o o-25 C to +75 C (-13 F to 581 F).

5% to 95% non condensing.

IP 51 (IP 54 front option).

12 to 14 SWG.

EDC

MULTI CHANNEL DC ENERGY METER

Common Features :

Single meter measures Multiple channels and True RMS measurements.

Differential current input for all the current channels.

Voltage Full scale programmable.

Current full scale programmable independently.

Reverse lock option for not accumulating the reverse current energy. This can be

used for the better study of charging and discharging circuit.

Programmable shunt secondary 50mV to 75mV.

Energy display programmable-counter based or resolution based.

Energy resetting at 999999*PT.Pri*CT Pri.

Auto scaling of kilo and mega decimal point.

Optional programmable relay output maximum 2 (upto 6 threshold parameters)

and tripping time upto 180 seconds.

Specifica�on Descrip�on

Accuracy:

Communication:

Baud rate:

Isolation:

Weight: OperatingTemperature:

StorageTemperature: Humidity:

Protection index:

Display Resolution:

Input voltage:

Input current:

Aux-Supply:

Recommended

connection wire:

92mm

44

mm

90 mm

90 m

m

Panel

Clamp

Panel Cutout

Input Frequency:

Page 5: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

DIGITAL MULTIFUNCTION

LOAD MANAGER

LGP & MGP

SIMULTANEOUS MEASUREMENT

OF VARIOUS ELECTRICAL

PARAMETERS!

Intertek4007051

CM

Contact for certification details

www.elmeasure.com

Basic | Power | Energy | Load Manager | Digital Output | Pulse Output

www.powercorporation.in

Page 6: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

Features :

Accuracy Class 1.0 (default) as per IEC 62053-21,

Class 0.5 as per IEC 62053-22 (Optional).

True RMS measurement.

Simultaneous sampling of Volts & Amps.

Energy display programmable-counter based or

resolution based.

Energy resetting at 999999 kVAh* Transformer

Ratio

Positive energy accumulation even with CT

polarity reversal, reverse lock programmable.

User programmable password protection.

Auto scrolling.

Auto-scaling of Kilo, Mega, Giga and Decimal

point.

Low PT, CT burden.

Front LED pulse 1250 imp/kWh of secondary

input.

Programmable PT, CT ratio upto 2000 MVA.

Programmable kVAh (default kWh) for meters

with Energy parameter.

Wide Measurement range - 10mA - 6A.

Clearance and Creepage distance meets safety

standard.

Finger touch proof terminals to voltage and

current connections.

Parameter name & value displaying using 7 seg

LEDs.

6 digits display on each row for better readability.

Available in LED (3 row, 2 row and 1 row), LCD,

Dinrail (1 row).

Field programmable Star (Wye) or Delta or Single

phase configuration.

Optional Features :

Communication with PCs, PLCs, DCS through optional optically isolated RS 485/ RS 232 serial Interface.

Pulse output - programmable pulse width of 50 mS to 500 mS (for LG plus models only).

Programmable Relay output - refer Product Selection Table.

+LG 3399

Displays PF, Wh or VAh (programmable), OLD and

user selectable parameters from Basic (VLL, VLN, A,

Hz) or W or VA (any 2).

Displays more than 15 parameters.

3 row LED display with 6 digits each.

‘OLD' register to store the previously cleared

energy value.

Note: No up-gradations and no optional features

except RS 485

+LG 5310

Quick and Easy navigation and programming.

Displays more than 25 parameters Basic, Power and

Energy.

Basic : VLL, VLn, A, (Avg. & PW), F, RPM.

Power : W, PF, VA, (Avg. & PW)

Energy : Wh, Hi. Amps, LH, OLD Wh, OLD LH, ON

Time (non resettable).

OLD register to store the previously cleared energy

value and its corresponding LH.

Optional - Programmable relay output (upto 2) for

any threshold of Under & Over ( Voltage, Amps,

Frequency), Under PF, Over Watts, Over Wh, Phase

missing.

Programmable tripping time up to 180 sec. with

hysteresis of 1%.

+ +LG 1129 /LCD, µG 1129

+LG series has optional optically isolated RS485 or pulse output, which can be integrated into a

process through a PLC/DCS for online energy management

For pulse output, if the DCS/PCS has a self excited 12V or 24V, external 24V DC supply is not required.

+LG 5110 µG/Dinrail/LCD

+ +LG 1119 /LCD, µG 1119

Field programmable W or VA or PF or Wh (any

one parameter). Factory configured : Wh.

Displays programmed parameter name and

value for instantaneous parameters.

Reduces complexity of stocking as this can be

used for multiple measurement applications.

OLD register to store the previously cleared

energy value.

Note: Also available in dinrail version

Field programmable to Basic (VLL, VLN, A, F) or W or

VA or PF or Wh (any two parameters). Factory

configured : Wh, PF.

Displays programmed parameter name and value

for instantaneous parameters.

Reduces complexity of stocking as this can be used

for multiple measurement applications.

OLD register to store the previously cleared energy

value.

R

V - A - Hz

Y B Hz

K

A 3VAF+

VLL VLN A

ALPHA+PRG

ALPHA+

PRG

MINUS

AMPS DC

K

A ADC+

Wh

LG 1 1 19+

LITTLE GENIUS+

PRG

OLDREV

W

VA

PF

VAF

Application Information:

Displays Basic : VLL, VLn, A (Avg. & PW), F.

Power: W, PF,VA (Avg. & PW). Energy : Wh, LH,

Old Wh, Old LH.

Energy is programmable to Wh or VAh with 7

digit resolution (LCD), 6 digit resolution (LED)

and 4 digit resolution for instantaneous

parameters.

OLD register to store the previously cleared

energy value and its corresponding LH.

80 to 300 V AC/DC auxiliary supply.

Optional - Programmable relay output (upto

2 in LCD version and 1 in LG+ 5110) for any

threshold of Under & Over(Voltage, Amps,

Frequency), Under PF, Over Watts, Over Wh,

Phase missing.

Programmable tripping time upto 180 sec

with hysteresis of 1%.

Energy Reset : 999999 kVAh × Transformer Ratio.

0.4kto

4.0k

0.01

4.01kto

40k

0.1

40.1kto

400k

1.0

400.1kto

4,000k

10

4 Mto

40 M

100

40 Mto

400 M

1000 10000

400 Mto

4000 M

KWH MWH GWH

Multiplication Factor:

Full Scale Watts

3 V Pri LL x A Pri

Unit of display

Multiplication factor for counter based energy mode:

Page 7: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

DUAL SOURCE ENERGY METER

+ + +LG 5220 / LG 3220 / LG 5120L

MON FEATURES

Automatic switching of display based on input

source (EB/DG).

Load hours and ON hours for both sources.

Positive energy accumulation / reverse lock

programmable.

Programmable to kWh or kVAh.

‘OLD' registers to store the previously cleared

energy values.

Additional Features: LG 5220

2 Row display with 6 digits each.

Simultaneous display of Energy for EB & DG in

single page.

Displays Basic : VLL, VLn, A (Avg. & PW), F.

Power : W, PF (Avg. & PW).

Energy : Wh, LH, ON hrs OLD Wh, OLD

LH(both for EB & DG)

Optional - Programmable relay output upto 2

relays.

Options : Under Voltage, Over Voltage, Under

Amps, Over Amps, Under Frequency, Over

Frequency, Under PF, Over Watts, Over Wh, and

Phase missing (both for EB & DG).

Programmable tripping time upto 180 sec with

hysteresis of 1%.

Additional Features: LG 3220

2 Row display with 6 digits each.

Simultaneous display of Energy for EB & DG in

single page.

Displays W, PF (Average & Phasewise).

Wh, OLD Wh, (both for EB & DG)

Optional - Programmable relay output upto 2

relays.

Options : Under PF, Over Watts, Over Wh, and

Phase missing (both for EB & DG).

Programmable tripping time upto 180 sec with

hysteresis of 1%.

Additional Features: LG 5120L

Energy is programmable to Wh or VAh with 7

digit resolution and 4 digit resolution for

instantaneous parameters.

Displays Basic : VLL, VLn, A (Avg. & PW), F.

Power : W, PF (Avg. & PW).

Energy : Wh, LH, ON hrs., OLD Wh, OLD

LH (both for EB & DG)

Optional - Programmable relay output upto 2

relays.

Options : Under & Over (Voltage, Amps,

Frequency), Under PF, Over Watts, Over Wh, and

Phase missing (both for EB & DG).

Programmable tripping time upto 180 sec with

hysteresis of 1%.

Common Features

Additional Features: LG 5220

LG+ 3220 ( Two Row / 3121 (Single Row)

LG+ 5120L

Typical Connection Scheme for Dual Energy Measurements

Note: Additional error of 0.1% of full scale, for meter input current below 500mA

R Y B N

AMF PANEL

Potential free

contact

R

Y

B

N

R

Y

B

N

Require only 240V AC as AMF input

Source 2

PowerGrid Power

METER NMETER 1

Technical Specification :

Specification Description

Accuracy:

Sensing/Measurement:

Input voltage:

Input Frequency:

Input current:

Aux-Supply:

Display Type:

Display Resolution:

CT PT Ratio Max:

Communication:

Weight:

Class 1 Default as per IEC 62053-21, Class 0.5 as per IEC 62053-22.

True RMS, 1 Sec update time. 4 Quadrant Power & Energy.

4 Voltage inputs (VR, VY, VB, VN).

Programmable 110 or 415V LL Nominal (Range 50 to 550V LL).

Primary Programmable up to 999 kV. Burden: 0.2VA Max. per phase.

45 - 65Hz

Current inputs (AR, AY, AB) 500mA - 6A (Field configurable 1A or 5A).

Primary programmable up to 99 kA.

Overload: 10A max continuous, 50A max for 3 Sec.

Burden: 0.2VA Max. per phase.

(Control Power)- 80 - 300V AC/DC, 40-70Hz. Burden: 5VA Max

LG+/µG+: 10mm height bright red LED display. LCD: 10mm height bright LCD.

4 digits for instantaneous, Integrated: 6digits for LED, 7digits for LCD

2000 MVA programmable.

Rs485 serial channel connection, Industry standard Modbus RTU protocol

(RS232 optional).

Baud rate: 4800 bps to 19200 bps. (Preferred 9600bps).

Isolation: 2000 volts AC isolation for 1 minute between communication and

other circuits.

Unpacked: 300 gms, Packed: 400 gms.

OPTION 2

Non-Dual Source Meter

RS 485

Gateway

Wireless Non-Dual Source Meter (Zigbee or WiFi)

METER 1METER 64

METER 1 METER 64

Serv

er

METER 2

DG

Ethernet to PLC

PLC to

Ethernet

Gateway

PLC

METER 2

Wh

LG 1 1 1 9+

LITTLE GENIUS+

PRG

OLDREV

W

VA

PF

OPTION 1

ECO friendly lead free 18 months warranty

Page 8: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters

| Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input

Output | Transducers | Converters

HO & Unit-I:

Plot No.: 47-P, Hardware Park, KIADB,

Huvinayakanahalli, Jala Hobli, Yelahanka Taluk,

Bengaluru - 562149 Karnataka INDIA.

E: [email protected]

Unit-II:

Goutham Garden, No. 4, Veerapandi,

Coimbatore - 641019 Tamilnadu INDIA

T: 0422 2697200 TF: 0244 2695200

E: [email protected]

Unit-III:

#764, 4th Phase, 707, Yelahanka New Town,

Bengaluru - 560 064 Karnataka INDIA

T: +91 80 28461744

E: [email protected]

ELMEASURE INDIA PRIVATE LIMITED

Product Selection Guide :

Mechanical Specification:

Safety: Designed to meet protection class III, pollution degree 2.

Protection against shock by double insulation.

Clearance and Creepage meets as per UL 61010 safety standard.

Finger touch proof terminals to voltage and current connections.

Environment:

Operating temperature -10°C to +55°C (14°F to 131°F)

Storage temperature -25°C to +70°C (-13°F to 158°F)

Humidity 5% to 95% non condensing.

Protection index IP 51 (IP 54 front option)

Recommended wire gauge 12 to 14 SWG

Safety and Environmental SpecificationApplicable Standards :

Test of insulation properties

Test of Accuracy requirements

Test of electrical requirements

Radio interference suppression

Fast transient burst test

Damped oscillatory waves immunity test

Test o f immunity to electromagnetic RF fields

Test of immunity to conducted disturbances,

Induced by radio-frequenc y fields

Test of immunity to electrostatic discharges

Surge immunity test

Test of the effect o f the climatic environments

Mechanical tests

Test of protection against penetration of dust

and water

Test of resistance to heat and fire

IEC 60060-1

IEC 62052-11

IEC 62052-11

CISPR 22

IEC 61000-4.4

IEC 61000-4.12

IEC 61000-4.3

IEC 61000-4.6

IEC 61000-4.2

IEC 61000-4.5

IEC 60068-2

IEC 60068-2

IEC 60529

IEC 60695-2

Safety standard IEC 61010 – 1

MODEL NO.

BASIC POWER ENERGY OPTIONAL FEATURE

LG 5110+

LG 5310+

LG 3399+

LG 5220 (DS)+

LG 3220 (DS)+

LG 1119+

µG 5110+

LG 1129+

LG 1100+

µG 1119+

µG 1129+

µG 1100+

LG 5110L+

LG 5120L+

LG 1119L/D+

LG 1129L/D+

LG 5110D+

ACC

CLASS

1.0/0.5VLL

RYB

VLL

VLL

VLL

VLL

VLL

VLL

VLL

VLL

VLL

Load Hrs/

ON Hrs

PULSE

O/P

DIGITAL

O/PRS485

LH

LH & OH

LH

LH

LH

LH

LH & OH

1

2

2

2

1

2

2

1

LCD / DinRail Version

+LG 3399: Wh and PF any two parameters [Basic (VLL,VLN,AMP,Hz) or W or VA] programmable+LG /µG+ 1119/L/D: Any one parameter [W or PF or VA or Wh] programmable+LG /µG+ 1129/L/D: Any two parameters [Basic (VLL,VLN,AMP,Hz) or W or PF or VA or Wh] programmable

# kWh / kVAh Programmable at site.Zigbee Communication Option Analog Output For DinRail Version only RS485 Communication Option

AMP

RYB

AMP

AMP

AMP

AMP

AMP

AMP

AMP

AMP

AMP

W

RYB

W

W

W

W

W

W

W

W

W

PF

RYB

PF

PF

PF

PF

PF

PF

PF

PF

PF

Hz

Hz

Hz

Hz

Hz

Hz

Hz

Hz

Hz

Hz

VA

RYB

VA

VA

VA

VA

VA

VA

#kWh/

kVAh

Wh

Wh

Wh

Wh

Wh

Wh

Wh

Wh

Wh

Wh

OLD

ENERGY

OLD

OLD

OLD

OLD

OLD

OLD

OLD

OLD

OLD

OLD

OLD

OLD

OLD

OLD

OLD

OLD

RS232VLN

RYB

VLN

VLN

VLN

VLN

VLN

VLN

VLN

VLN

VLN

Dimension Bezel: 96 x 96 mm (Depth 50mm behind Bezel)

96 × 48 mm (Depth 45mm behind Bezel)

Panel Cutout:+2 +290 x 90 mm-0 -0 +2 +290 x 42 mm-0 -0

92mm

44

mm

90 mm

90 m

m

Panel

Clamp

Panel Cutout

LG 3100+

PC

/LG

P/V

7/1

01

7

Restricted Option

Sales Offices: BANGALORE | CHENNAI | COIMBATORE | MUMBAI | DELHI | HYDERABAD | USA | UAE Sales Offices: BANGALORE | CHENNAI | COIMBATORE | MUMBAI | DELHI | HYDERABAD | USA | UAE

Page 9: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

Contact for certification details

www.elmeasure.com

Intertek4007051

CM

DEMAND CONTROLLER

EN & PN

Multifunction Meter | Load Manager | Import Export | Harmonics |

Digital/Analog Input or Output | K-factor

HIGH-END

MULTIFUNCTION METER

FOR COMPREHENSIVE

ENERGY MANAGEMENT!

www.powercorporation.in

Page 10: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

Features:

True RMS measurement.

Simultaneous sampling of Volts & Amps.

High / low recording VLL, VLN, A, Hz, W, VA, PF,

VAr value storage with time stamp.

Byte order option - Field Programmable Float /

Little Endian / Big Endian data format.

Accuracy class 1.0 as per IEC 62053-21, 0.5s

option).

User programmable Password Protection.

Auto-Scaling of Kilo, Mega and Giga decimal

point.

Neutral Current (calculated) , RPM display.

Clearance and Creepage distance meets

UL- 61010.

Programmable starting current in % of 5A

secondary. Default 0.4%.

Selectable VA measurement - Vector/Arithmetic/

Vector harmonics.

K-Factor V & A (all three phase).

Programmable parameter update rate - 1sec. to

5sec. (Default 1sec.).

Programmable Auto scrolling time - 1 sec. to 10

sec. (Default 5 sec.).

Dynamic communication - user selectable

register map.

Programmable Energy display - Counter based or

Resolution based.

Energy resetting @ 999999 kVAh × Transformer ratio.

Reverse lock, user programmable for positive energy

accumulation. (Default: No lock)

Front LED pulse 10000 imp/kWh.

OLD register to store previously cleared energy & LH

values.

% of unbalance V & A for all the phases.

THD for Voltage and Current.

Ampere hour (Ah) and PF average parameters.

Phase Angle measurement.

Optional Features EN, PN :

Digital outputs - 4 potential free contacts with

programmable time delay. Hysteresis 1%.

Trip time 1 to 180 sec. Programmable.

TOD option ( Energy & Demand upto 6 slots ).

User programmable - Pulse output (POP) on time -

50 to 500 msec.

Analog / Digital I/p upto 2. Accuracy class 1% FS

Analog Output - Two independently programmable

to 0-20 mA (or) 4-20 mA output, configurable to any

VLL, A, F, W, PF, VA parameters.

Individual Harmonics upto 31st order.

Datalogger - 1MB / 8MB optional.

Additional Features for PN2 programmable parameters.

Phase wise Voltage & Current Wave Forms.

LCD 7 parameter display at a time, 7 digit

energy.

Wave form communication through ELNET

Software.

Power save mode with Enable/Disable

option.

Demand Controller with 1 Relay, 2 Relay & 4

Relay outputs.

RTC can be adjusted using external

communication.

Upto 60A or 100A direct measurements using

Hanging CT.

Dual port communication.

Demand updation @ 1 sec.

Ethernet / Zigbee communication.

Features ParametersPN7700LMEN8400LM

PN7710EN8410

PN7710DMCEN8410DMC

Default Optional feature - no restriction on combination of options

Restricted optional feature - Combination of all restricted options may not be possible in a single product

LM : Load Manager

DMC : Demand Controller

*Indicates Non UL/ETL products

}

Basic

Line to Neutral Voltage VLN Avg, VR-N, VY-N, VB-N

Line to Line Voltage VLL Avg, VR-Y, VY-B, VB-R

Line Current A Avg, AR, AY, AB,

Neutral Current Computed AN

Frequency, RPM (Generator application) Hz, RPM

V & A Phase Angle VR, VY, VB, AR, AY, AB

Unbalance V & A % V, % A, VR, VY, VB, AR, AY, AB

Power

Active Power W Total, WR, WY, WB

Apparent Power VA Total, VAR, VAY, VAB

Reactive Power VAR Total, VAR R, VAR Y, VAR B

Power Factor PF Avg, PFR, PFY, PFB

Energy / Integrated

Active Energy Wh

Apparent Energy VAh

Reactive Energy VARh-Ind, VARh-Cap

Load Hrs, No. of Interruption, Life Timer LH, Intr, On.Hr Ah, PF Avg

Old (Energy, Load Hrs) Old (Wh, VAh, VARh Ind/Cap, LH, ) PF, AVG, Ah

Harmonics

Voltage THD THD% VR, VY, VB

Current THD THD% AR, AY, AB

K Factor K Factor: VR, VY, VB, AR, AY, AB

Events (High/Low)/ With time stamp

Voltage VLL, VLN VLL, VLN

Current A

Frequency Hz

VA VA

Watts W

VAR VAR

Power Factor PF

Demand (Optional)* Programmable to any one of the below

Active Power (W) Watt

Apparent Power (VA) VA

Reactive Power (VAR) VAR

Current Average (A.Avg) A Avg

Control Features (Optional)*

Digital Output (Up to 4 relay)

Tripping time (1-180 sec)

Analog Output / Analog Input Up to 2

Special Features (Optional)

Data Logging with Time stamp 1MB/8MB. Refer Table 1

Received/Delivered (Import/Export)/Net Wh, VAh, VArh Ind/Cap,{ PF.Avg, Ah } only Rec & Del , Lh

60A, 100A Direct measurement* 3 Phase (Hanging CT)

Individual Harmonics V & A ( All Three Phases )

Communication (Optional)*

RS-485 or RS-232 (MODBUS) or Ethernet or Zigbee* RS 232 / RS 485 / Ethernet / Zigbee

Programmable sliding/block,

demand period, forcast/

step demand control

31st 31st 31st

RTC

Based

RTC

Based

4 relay

Sliding

window

2 relay

Page 11: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

EN 8499 Note: This model can be customized for any parameters available in EN 8400LM

Displays all Energy parameters (Wh, VAh, VARh ( Inductive & Capacitive) parameters.

Received /Delivered (Import/Export) Energy option.

Separate Load hours for Received, Delivered and Net.

OLD register to store previously cleared energy values and load hours.

Pulse output - Programmable pulse width of 50 mS to 500 mS (Optional).

RS 485/232 Optional.

Key Unique Features

Demand Management :

Monitoring - Helps to visualise the demand profile during a billing cycle.

Demand peaks with date & time can be identified in the meter as well as

ElMeasure's ElNet software. The events can be studied and related with the

production events such as starting of furnace or a large motor etc., and helps to

decide on switching/staggering of loads etc.

Control - Enables user to program the threshold values of max demand and

initiate ALARM/ CUT-OFF when the Forecast Demand/ Present Demand/ Max

Demand surpasses the threshold values. This will help the user from exceeding

the sanctioned demand and avoid causing a trip or paying huge penalty.

Additional Load - By this feature the user shall be able to decide to transfer the

exact quantum of load from EB to DG or vice versa for economic power.

High Low Event Recording for V, A, Hz, VA, W, VAr, PF

Protection of 3 phase system against single phasing, low & high voltage, over

load, highly lagging and leading PF, Hz etc. Navigator can trap such events for

future reference.

Identify, record unbalance voltage,

currents and helps the user to identify the

root cause. Unbalance over-burdens the

electrical system and affects in the form of

over loading of cables, motors and

switchgear.

PF Management :

Lower the Avg PF higher the system

inefficiency. So this enables the user to

maintain a healthy PF level. The Digital

output features can be used to initiate

alarm when the Avg PF crosses the user

programmed threshold values (Lead/ Lag).

Data Logging with Time Stamp:

The information is needed in all types of businesses to determine performance,

quality, efficiency, cost reduction, fuel consumption monitoring and many other

critical factors. This feature provides important and accurate data for analysis.

WVA

VLL

Harmonics up to 31st level

Presence of THD will urge the user to identify

the polluting loads and take necessary action

to mit igate harmonics through an

appropriate harmonic filter, save energy to

improve plant & equipments efficiency.

Monitors Basic , Power & Energy

Parameters

Provides the complete spectrum of Electrical

system and helps in study of load pattern.

Process Integration:

Integration of process parameters such as temperature, Oil level, RPM, Pressure

etc. giving greater flexibility to monitor them along with electrical parameters.

Control Features:

4 user defined potential free Digital Output based on threshold setting for

protection relay for any parameter with programmable trip time to protect the

equipments from electrical abnormalities.

Power Quality Check/Management:

Monitoring phase angle will help the user to identify the causes such as

deterioration in the distribution transformers, cables & cable termination,

presence of harmonics etc.

Cross Verification of Electricity Billing:

Helps the user to cross verify with the tariff meter and initiate suitable action if the

values have a wide disparity.

Automatic connection or disconnection of Gensets connected to common

bus .

Keep equipment in safe region.

Protection of equipment from Under/ Over Voltage or Current or

Frequency.

Process control.

Protection of 3 phase equipment from Single phase prevention, Over load

etc.

Typical ApplicationsDigital Outputs : (Up to 4 relay Outputs)

4 User defined potential free relay outputs based on threshold setting.

Protection relay for any of Under/Over VLL, A, Hz Over (W, VA, Wh) Under

(PF), Phase reversal, Single Phase, Analog inputs.

Digital O/P parameters- A.Thd, V.Thd, rev.A, S1 phase, wh .revd, VA, W, under

PF, under ( Analog I/P 1 , Analog I/P 2, F, A, VLL), over ( Analog Input 1, 2 , F,

A, VLL)(A.thd, V thd), An In 1 & 2 ( Under & Over), rev A, S1 .ph, wh.recd, PF,

VA,W, (under & over ) [F,A,VLL] also for RD models, wh.devd.

Programmable trip time 1 to 180 sec to suit different load conditions.

Rating of control relays: NO contact SPST 2A, 250 VAC / 30 VDC .

Page 12: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

PC

/NA

V/V

7/1

017

Multiplication factor for counter based energy mode

Applicable Standards:

Safety: Designed to meet protection class III, pollution degree

2.

Protection against shock by double insulation.

Clearance and creepage meets UL 61010 safety standard.

Finger touch proof terminals to voltage and current

connections.

Environment:

Safety and Environmental Specifications:

Energy Reset : 999999 kVAh × Transformer ratio

1 Minute to 12 hours

interval programmable.

Data interval and

parameter can be

selected through

communication.

No of RecordsNo of

Parameters 1MB 8MB

Table 1

1

2

4

9

14

29

121920

81280

48768

24384

16256

8128

982080

654720

392839

196416

130944

65472

Optional

Programmable

Data Logging

Multiplication

Factor:

Full Scale kW

3 V Pri LL x A

Pri / 1000

0.4kto4.0k

0.01

4.01kto40k

0.1

40.1kto400k

1.0

400.1kto4,000k

10

4Mto40 M

100

40 Mto400 M

1000 10000

400 Mto4000 M

Unit of display KWH MWH GWH

Test of insulation properties

Test of Accuracy requirements

Test of electrical requirements

Radio interference suppression

Fast transient burst test

Damped oscillatory waves immunity test

Test o f immunity to electromagnetic RF fields

Test of immunity to conducted disturbances,

Induced by radio-frequenc y fields

Test of immunity to electrostatic discharges

Surge immunity test

Test of the effect o f the climatic environments

Mechanical tests

Test of protection against penetration of dust

Test of resistance to heat and fire

IEC 60060-1

IEC 62052-11

IEC 62052-11

CISPR 22

IEC 61000-4.4

IEC 61000-4.12

IEC 61000-4.3

IEC 61000-4.6

IEC 61000-4.2

IEC 61000-4.5

IEC 60068-2

IEC 60068-2

IEC 60529

IEC 60695-2

Safety standard IEC 61010 – 1

and water

-10°C to +55°C (14°F to 131°F)

-25°C to +70°C (-13°F to 158°F)

5% to 95% non condensing.

IP 51 (IP 54 front option)

12 to 14 SWG with U type

lug of 6.75 mm width max.

Operating temperature

Storage temperature

Humidity

Protection index

Recommended connecting

wire

Specification Description

Technical Specification:

Mechanical Specification:

90 mm

90

mm

Panel

Clamp

Dimension Bezel: 96 x 96 mm (Depth 50mm behind Bezel)

Panel Cutout:+2 +290 x 90 mm-0 -0

90

mm

96

mm

50 mm Panel Cutout

Class 1 Default , as per IEC 62053-21

Class 0.5, 0.5S as per IEC 62053-22

True RMS, 1 Sec update time.4 Quadrant Power & Energy

(RD Option).

4 Voltage inputs (VR, VY, VB, VN)

Programmable 110 or 415V LL Nominal (Range 80 to 520 VLL)

Primary Programmable up to 999 kV. Burden: 0.2VA Max. per phase.

45 - 65 Hz

Current inputs (AR, AY, AB) 50mA - 6A (Field configurable 1A or 5A).

Primary Programmable up to 99 kA.

Overload: 10A max continuous, 50A max for 3 Sec

Burden: 0.2VA Max. per phase.

Control Power 80 - 300V AC/DC, 40-70Hz, 48V DC (optional)

Burden: 5VA Max.

eNavigator: 10mm height bright red LED display

Power Navigator: 6mm height bright LCD graphical display.

4 digits for instantaneous,Integrated: EN - 6 digits, PN - 7 digits.

2000 MVA Programmable. Note : Additional error of 0.1%.

Rs485 serial channel connection, Industry standard Modbus RTU

protocol (Optional: RS232 / Ethernet / Zigbee).

Baud rate: 4800 bps to 19200 bps. (Preferred 9600 bps)

Isolation: 2000 volts AC isolation for 1 minute between

communication and other circuits.

Zigbee communication (Range: 50 meter length)

Unpacked: 300 gms, Packed: 400 gms

Accuracy:

Sensing/

Measurement:

Input voltage:

Input Frequency:

Input current:

Aux-Supply:

Display Type:

Display Resolution:

CT PT Ratio Max:

Communication:

Weight:

Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters

| Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input

Output | Transducers | Converters

Sales Offices: BANGALORE | CHENNAI | COIMBATORE | MUMBAI | DELHI | HYDERABAD | USA | UAE

HO & Unit-I:

Plot No.: 47-P, Hardware Park, KIADB,

Huvinayakanahalli, Jala Hobli, Yelahanka Taluk,

Bengaluru - 562149 Karnataka INDIA.

E: [email protected]

Unit-II:

Goutham Garden, No. 4, Veerapandi,

Coimbatore - 641019 Tamilnadu INDIA

T: 0422 2697200 TF: 0244 2695200

E: [email protected]

Unit-III:

#764, 4th Phase, 707, Yelahanka New Town,

Bengaluru - 560 064 Karnataka INDIA

T: +91 80 28461744

E: [email protected]

ELMEASURE INDIA PRIVATE LIMITED

ECO friendly lead free 18 months warranty

Page 13: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

BM

SIMULTANEOUS MEASUREMENT

OF VARIOUS ELECTRICAL

PARAMETERS!

www.elmeasure.com

BRANCH CIRCUIT MONITORMulti Channel Load Manager | Cost Saving | Compact Design

BM 5120

1

2

3

4

www.powercorporation.in

Page 14: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

A/C Load

Data

Center

Motor/PumpsLoadLMS

Multi-channel data collection.

3 Phase, 4 channels or Single phase 12 channels

Displays Basic, Power and Energy parameters.

Optional Pluggable Zigbee communication or Ethernet

( Default RS 485).

Space saving compact design for easy installation into

existing panel boards.

True RMS measurements.

Simultaneous sampling of Volts & Amps.

Accuracy class 1.0 as per IEC 62053-21, Class 0.5 as per IEC

62053-22.

User programmable password protection.

Energy resetting @ 999999 KVAh × Transformer ratio.

Features:

Displays more than 25 parameters Basic, Power and Energy.

Displays Basic : VLL, VLn, A (Average & Phasewise), F.

Power: W, PF,VA (Total & Phasewise).

Energy : Wh, LH, VAh, VARh ( PhaseWise for every Channel & Total Channel

wise).

OLD register to store the previously cleared Energy value & LH.

Measures:

Specification of Zigbee (coordinator and Router) :

Network Support IEEE 802.15.4 and Zigbee

Data Rates 256 kbps

Frequency Band 864 MHz – 865 MHz (16 channels) with auto

scanning

Modulation techniques DSSS

Wireless Security AES 128-bit encryption

Tx Output Power 4.5 dBm Rx

Sensitivity -97 dBm

Distance covered 20 meters

Note: Customization can be done for other parameters

provided volume justify

Connection Details:

The Branch Circuit Monitor (Power Distribution Unit) is ideal in Data center

where it can connect and control up to 12 channels of Branch monitoring.

Controlling can be done using add on Relay unit with Rs485. BM is a meter for

measuring Voltage, Current, Power and Energy for every circuit in a power

distribution unit or Rack. One can use Split core CTs or Regular CTs to monitor

the current in every branch

BRANCH CIRCUIT MONITOR (BM)

MODBUS

ENERGY MANAGEMENT SOFTWARE

Solution Architecture :

Connection Details:

Optional

Zigbee | Ethernet |

GPRS Module with memory

up to 14 GB

GW 2000D

BM 5120

1

2

3

4

BM 5120

1

2

3

4

Page 15: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

Address

Communication Register Map:

Sl No. Parameter Data TypeChannel 1 Channel 2 Channel 3 Channel 4

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

Watts Total

Watts R phase

Watts Y phase

Watts B phase

PF Ave. (Inst.)

PF R phase

PF Y phase

PF B phase

VLL average

Vry phase

Vyb phase

Vbr phase

VLN average

V R phase

V Y phase

V B phase

Current Total

Current R phase

Current Y phase

Current B phase

Frequency

Wh Received

R-Phase Wh

Y-Phase Wh

B-Phase Wh

Load hour Recd

R-Phase load hour

Y-Phase load hour

B-Phase load hour

VAR total

VAR R phase

VAR Y phase

VAR B phase

VA total

VA R phase

VA Y phase

VA B phase

VAh total

VARh IND total

VARh CAP total

VAh R phase

VAh Y phase

VAh B phase

VARh IND R phase

VARh IND Y phase

VARh IND B phase

VARh CAP R phase

VARh CAP Y phase

VARh CAP B phase

float

float

float

float

float

float

float

float

float

float

float

float

float

float

float

float

float

float

float

float

float

float

float

float

float

Unsigned Long

Unsigned Long

Unsigned Long

Unsigned Long

float

float

float

float

float

float

float

float

float

float

float

float

float

float

float

float

float

float

float

float

4101

4103

4105

4107

4109

4111

4113

4115

4117

4119

4121

4123

4125

4127

4129

4131

4133

4135

4137

4139

4141

4143

4145

4147

4149

4151

4153

4155

4157

4159

4161

4163

4165

4167

4169

4171

4173

4175

4177

4179

4181

4183

4185

4187

4189

4191

4193

4195

4197

4201

4203

4205

4207

4209

4211

4213

4215

4217

4219

4221

4223

4225

4227

4229

4231

4233

4235

4237

4239

4241

4243

4245

4247

4249

4251

4253

4255

4257

4259

4261

4263

4265

4267

4269

4271

4273

4275

4277

4279

4281

4283

4285

4287

4289

4291

4293

4295

4297

4301

4303

4305

4307

4309

4311

4313

4315

4317

4319

4321

4323

4325

4327

4329

4331

4333

4335

4337

4339

4341

4343

4345

4347

4349

4351

4353

4355

4357

4359

4361

4363

4365

4367

4369

4371

4373

4375

4377

4379

4381

4383

4385

4387

4389

4391

4393

4395

4397

4401

4403

4405

4407

4409

4411

4413

4415

4417

4419

4421

4423

4425

4427

4429

4431

4433

4435

4437

4439

4441

4443

4445

4447

4449

4451

4453

4455

4457

4459

4461

4463

4465

4467

4469

4471

4473

4475

4477

4479

4481

4483

4485

4487

4489

4491

4493

4495

4497

*Optional (26-49)

Page 16: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters

| Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input

Output | Transducers | Converters

Sales Offices: BANGALORE | CHENNAI | MUMBAI | DELHI | HYDERABAD | USA | UAE

HO & Unit-I:

Plot No.: 47-P, Hardware Park, KIADB,

Huvinayakanahalli, Jala Hobli, Yelahanka Taluk,

Bengaluru - 562149 Karnataka INDIA.

E: [email protected]

Unit-II:

Goutham Garden, No. 4, Veerapandi,

Coimbatore - 641019 Tamilnadu INDIA

T: 0422 2697200 TF: 0244 2695200

E: [email protected]

Unit-III:

#764, 4th Phase, 707, Yelahanka New Town,

Bengaluru - 560 064 Karnataka INDIA

T: +91 80 28461744

E: [email protected]

ELMEASURE INDIA PRIVATE LIMITED

PC

/BM

/V0

/11

17

Safety and Environmental Specification:

Dimension Bezel : 90 x 90 mm (Depth 67mm)

Mechanical Specification:

Specification Description

Technical Specification:Applications :

Benefits :

For remote reading and control, the BM is

supported by ElNet Software, designed for

remote setup and data viewing and analysis.

Building Management System: With the open

modbus protocol, the BM can interface any

system, such as building management, HMI etc.

Compact : Ideal for Data Center.

Ideal for apartments / commercial complexes

billing and load pattern study on individual

phase.

Individual phase kWh measurement provides

user flexibility of measuring 3 phase 4 channels

or single phase 12 channels.

Primary current can be independently

configured making it ideal for any kind of

industry or up-gradation.

Safety: Designed to meet protection class III, pollution degree 2.Protection against shock by

double insulation. Clearance and Creepage meets as per UL 61010 safety standard.

Environment:

Operating temperature -10°C to +55°C (14°F to 131°F)

Storage temperature -25°C to +70°C (-13°F to 158°F)

Humidity 5% to 95% non condensing.

Recommended wire gauge 12 to 14 SWG

Note: Additional error of 0.1% of full scale, for meter input current

below 500mA for 5A setting

Accuracy: Class 1.0 (default) as per IEC 62053-21, Class 0.5 as per IEC 62053-22

(Optional).

Measurement Range: 1:500 for channel 1 & 2, 1:120 for channel 3 & 4

Sensing/

Measurement: True RMS, 1 Sec update time; 4 Quadrant Power & Energy

Input voltage: 4 Voltage inputs (VR, VY, VB, VN) Programmable 110 or 415V LL

Nominal (Range 80 to 550V LL) Primary Programmable up to 999 kV.

Burden: 0.2VA Max. per phase.

Input Frequency : 45 - 65 Hz

Input current: Current inputs [AR, AY, AB], 4 Channels - Each channel is

independently configurable. Primary Programmable up to 99 kA.

CT output : Can be upto 1000 mV or 100 mA from Split core CT or Hanging

CTs - Manufacturing option.

Aux-Supply (Control Power): 80 - 300V AC / DC, 40-70Hz. Burden: 5VA Max.

Display Resolution: 6 digit LED for Energy, 4 digit for Instantaneous

CT PT Ratio Max: 2000 MVA Programmable.

Communication: RS485 interface. Industry standard Modbus RTU protocol.

Baud rate: 4800 bps to 19200 bps. (Preferred 9600 bps)

Isolation : 2000 volts AC isolation for 1 minute between communication and

other circuits.

Weight:Unpacked: 300 gms Packed: 400 gms

Mechanical Specification: Dimension : 90mm * 72mm * 65mm

Current Transformers

Hang on CT- 5A or 50A or 100A

Split Core CT-100A | 400A | 1000A

Clip on CT-5A | 50A | 100A | 250A

ECO friendly lead free 18 months warranty

Page 17: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

ENERGY & PROCESS

MONITOR

EPM

Contact for certification details

www.elmeasure.com

User Friendly | Cost Effective | Field Programmable

DEVICE TO MONITOR

PROCESS AND ENERGY

TOGETHER!

www.powercorporation.in

Page 18: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters

| Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input

Output | Transducers | Converters

Sales Offices: BANGALORE | CHENNAI | COIMBATORE | MUMBAI | DELHI | HYDERABAD | USA | UAE

HO & Unit-I:

Plot No.: 47-P, Hardware Park, KIADB,

Huvinayakanahalli, Jala Hobli, Yelahanka Taluk,

Bengaluru - 562149 Karnataka INDIA.

E: [email protected]

Unit-II:

Goutham Garden, No. 4, Veerapandi,

Coimbatore - 641019 Tamilnadu INDIA

T: 0422 2697200 TF: 0244 2695200

E: [email protected]

Unit-III:

#764, 4th Phase, 707, Yelahanka New Town,

Bengaluru - 560 064 Karnataka INDIA

T: +91 80 28461744

E: [email protected]

ELMEASURE INDIA PRIVATE LIMITED

Specification Description

Accuracy:

Sensing/

Measurement:

True RMS, 1 Sec. update time. 4 Quadrant Power & Energy.

Input Voltage: 4 Voltage inputs (VR, VY, VB, VN).

Programmable 110 or 415V LL Nominal (Range 50 to 550V LL)

Primary programmable upto 999 kV. Burden: 0.2VA Max. per phase.

Input Current: Current inputs (AR, AY, AB), 500 mA – 6A (Field configurable 1A or 5A).

Primary programmable upto 99 kA.

Overload: 10A max. continuous, 50A max. for 3 sec.

Burden: 0.2VA Max. per phase.

Aux-Supply

(control power):

80 – 300V AC/DC, 40-70Hz.

Burden: 5VA Max.

4 digits for Instantaneous, Integrated: 6 digits.

CT Ratio: 2000 MVA programmable.

Display resolution:

Weight: Unpacked: 300 gms, Packed: 400 gms

Features :

Technical Specification:

Dimension Bezel: 96 x 96 mm (Depth 50mm behind Bezel)

90 mm

90 m

m

Panel

Clamp

Panel Cutout:+2 +290 x 90 mm-0 -0

Mechanical Specification:

90 m

m

96 m

m

50 mm Panel Cutout

Input Frequency: 45 - 65 Hz

True RMS measurement.

Simultaneous sampling of Volts & Amps.

Energy display programmable-counter based or

resolution based.

Energy resetting at 999999 kVAh × Transformer ratio.

Positive energy accumulation even with CT polarity

reversal, reverse lock programmable.

User programmable password protection.

Auto scrolling.

Auto scaling of Kilo, Mega, Giga and Decimal point.

Low PT, CT burden.

Displays - Basic: VLL, VLN, A (Avg. & Phase wise), F;

Power: W, PF, VA (Avg. & Phase wise); Energy: Wh or

VAh programmable (any one), Load hrs, Max & Min (

VLL and Amps), OLD Wh, OLD LH.

Front LED pulse 10000 imp/kWh of secondary input.

Programmable PT, CT ratio upto 2000 MVA.

Programmable kVAh (default kWh) for meters.

Energy is programmable to Wh or VAh with 6 digit

resolution LED and 4 digit resolution for

instantaneous parameters.

80 to 300 V AC/DC Auxiliary supply.

Additional Features:

EPM 5110

High & Low measurements for Voltage and Current

(Last one minute of data).Mm 2100

One Digital input (RPM). Measurement capability up

to 72000 RPM

Displays last one minute RPM. Cumulative RPM

through RS 485.

Optional: 2 Analog input for 4 – 20 mA or 0 – 20 mA

(Flow, Pressure, Temperature, etc.).

3 Digital Input optional.

Process Integration:

Integration of process

parameters such as

temperature, flow, pressure,

RPM, etc. giving greater

flexibility to monitor them

along with electrical

parameters.

DI

AI

PC

/EP

M/V

0/1

117

Clearance and creepage distance meets safety

standard.

Finger touch proof terminals to voltage and current

connections.

Parameter name and value displaying using 7

segment LED's.

Field programmable Star (Wye) or Delta or Single

phase configuration.

Class 1.0 (default) as per IEC 62053-21, Class 0.5 as per

IEC 62053-22 (Optional).

Communication: Rs485 serial channel connection, industry standard Modbus RTU

protocol (RS232 optional). Baud rate: 4800 bps to 19200 bps.

(Preferred 9600 bps.) Isolation: 2000 volts AC isolation for 1 minute

between communication and other circuits.

Intelligent:

ECO friendly lead free 18 months warranty

Page 19: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

INTELLIGENT

AUTOMATIC CHANGEOVER

WITH CURRENT LIMITER

iACCL

FOR A SEAMLESS,

UNINTERRUPTED CHANGEOVER

BETWEEN POWER SOURCES!

www.elmeasure.com

Current | Voltage | Frequency | Energy

www.powercorporation.in

Page 20: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

PC/IACCL/V3/1017

180 - 300V AC LN

the system will be

ON for DG delay time and OFF for cycle1 time and switches ON

once again. If the over current still present, it goes on with cycle

2,3,4,4,4 as per the no. of trip cycles programmed. If the ON / OFF

cycle is completed the device trips and permanently disables the

output. The reset can be done by pressing the reset key manually

40A).

Intelligent Overload tripping with AC1 to AC3 behavior

Energy (4 digit for single phase),

Or through the mobile app when network

Optional EB Energy and Voltage

Alpha

R NY B R NY B

is available

measurement for 3 phase

Upto 40A 100/125A

VAC

5 - 30 sec programmable 5 - 30 sec programmable

(Tripping based on

(Din rail option up to 40A)

AC3 behavior)

4 digitEnergy

ECO friendly lead free 18 months warranty

ACCL

32A

500 gms

90 x 76 x 6

iACCl 100 iACCl

Page 21: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

INTELLIGENT

EARTH FAULT RELAY

iEFR

FOR A SEAMLESS,

PROTECTION AGAINST EARTH

FAULT AND OVER LOAD/EARTH

TO NEUTRAL VOLTAGE

PRG

EFR 400Earth Fault Relay

COM

30sA

sA

SET A

MPS

SET TIMEsTsT

TESTRESET

www.elmeasure.com

Contact for certification details

www.powercorporation.in

Page 22: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

True RMS measurement.

Common protection for earth fault and over load

Clearance and creepage distance meets UL 61010 safety

standard.

Inverse curve - trip time is inversely proportional to fault

current. This EFR is Intelligent, when the fault current is 10

times higher than the set current, it trips 10 times faster.

Field programmable trip current and trip time through front

panel keys with password protection.

Continuous fault current display (Programmable) - fault

current continuously displayed to enhance the user to

understand the quality of electrical network / machine

online.

Continuous display of trip fault current (Programmable) - In

case of tripping, iEFR captures and displays the tripped

current with 4 digit resolution, which helps the user to

analyze and correct the problem.

Continuous scrolling display for set current and set time.

Wide input range 30mA to 5A and the trip time

programmable from 50ms to 30 seconds.

Manual test and reset keys.

RS485 communication option.

Features:

Microcontroller based design.

Password protection.

Current sensitivity wider range 30mA - 5A.

Programmable trip time 50ms - 30 sec.

Selection through soft keys (No DIP switches).

Continuous earth fault value display.

Intelligent tripping based on T 1/A or definite time

Auto scrolling of trip Info. & peak fault current.

SMT reflow manufacturing process.

Benefits:

Higher technological advantage.

Helps analysis and corrective action.

Security against mishandling.

No limitations on set current.

Wider choice to suit different industry

Better IP protection and longer life.

Helps online loss analysis.

Faster and reliable protection.

Better analysis.

Higher reliability.

Unique Features:

Technical Specification:

Specification Description

Accuracy: Class 2.0FS, Time delay ±5% with minimum of 50 ms.

Auxiliary voltage: 80 - 300 V AC / DC.

Input current: Programmable 30mA - 5A, Over current 30A.

Tripping time: Programmable for fault current, 30 MA to SA

Setting ranges: Low-set (I >) : 0.05A to 5.0ALow-set time (kt >) : 0.05, 0.1, 0.2, 0.3, 0.5, 1.0, 2.0, ......, 30 sec.High-set (I >>) : 0.1A to 30A or disable.High-set delay time (t >>) : 0.05 sec. to 30 sec.

Relay contacts: Two pair of potential free NO & NC contacts. One part to EFR 200D

Contact Rating: 2 or 4 Amps @ 240V AC / 24V DC.

Mounting Type: Flush or Dinrail

Communication: Rs485 serial channel connection industry standardModbus RTU protocol.Baud rate: 4800 bps to 19200 bps. (Preferred 9600 bps).Isolation: 2000 volts AC isolation for 1 minute betweencommunication and other circuits.

Tripping

Characteristics:

10sA

Protects control panels and switch boards from earth fault.

Protects motors / transformers / feeders / generators etc.,

from earth fault.

Hazardous and sensitive industries like oil refineries / pulp

industries / electrical distribution etc., can be protected.

Applications:

PC/IEFR/V1/1017

Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters

| Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input

Output | Transducers | Converters

Sales Offices: BANGALORE | CHENNAI | COIMBATORE | MUMBAI | DELHI | HYDERABAD | USA | UAE

HO & Unit-I:

Plot No.: 47-P, Hardware Park, KIADB,

Huvinayakanahalli, Jala Hobli, Yelahanka Taluk,

Bengaluru - 562149 Karnataka INDIA.

E: [email protected]

Unit-II:

Goutham Garden, No. 4, Veerapandi,

Coimbatore - 641019 Tamilnadu INDIA

T: 0422 2697200 TF: 0244 2695200

E: [email protected]

Unit-III:

#764, 4th Phase, 707, Yelahanka New Town,

Bengaluru - 560 064 Karnataka INDIA

T: +91 80 28461744

E: [email protected]

ELMEASURE INDIA PRIVATE LIMITED

ECO friendly lead free 18 months warranty

Page 23: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

INTELLIGENT

EARTH LEAKAGE RELAY

iELR

DETECT THE LEAKAGE

CURRENT IN AN INTELLIGENT

ELECTRICAL DEVICE!

www.elmeasure.com

Earth leakage current | Trip time

Contact for certification details

www.powercorporation.in

Page 24: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

True RMS measurement.

Clearance and creepage distance meets UL 61010 safety

standard.

Inverse curve - trip time is inversely proportional to fault

current. This ELR is Intelligent, when the leakage current is

10 times higher than the set current, it trips 10 times faster.

Field programmable trip current and trip time through front

panel keys with password protection.

Continuous leakage current display (Programmable) -

Leakage current continuously displayed to enhance the user

to understand the quality of Electrical network / Machine

online. This can be disabled through setup if required.

Continuous display of trip leakage current (Programmable) -

In case of tripping, iELR captures and displays the tripped

current with 4 digit resolution, which helps the user to

analyze and correct the problem. This can be disabled

through setup if required.

Continuous scrolling display for set current and set time.

Wide input range 300mA to 12A and the trip time

programmable from 300 ms to 30 seconds

(Optional 30 mA - 1A).

Manual test and reset keys.

RS485 communication option.

Features:

Microcontroller based design.

Peak detection and value display.

Password protection.

Current sensitivity wider range 300mA - 12A.

Programmable trip time 300ms - 30 sec.

Selection through soft keys (No DIP switches).

Continuous Earth Leakage Value Display

Programmable ).

Intelligent tripping based on T 1/A

Auto scrolling of trip Info. & peak fault current.

SMT reflow manufacturing process.

Benefits:

Higher echnological dvantage.t a

Helps nalysis and orrective ction.a c a

Security against ishandling.m

No imitations on et urrent.l s c

Wider hoice to uit ifferent ndustryc s d i

Better IP rotection and onger ife.p l l

Helps nline oss nalysis.o l a

Faster and eliable rotection.r p

Better nalysis.a

Higher eliability.r

Unique Features:

Tripping

Characteristics:

Protects control panels and switch boards from flame

leakage.

Protects motors / transformers / feeders / generators etc.,

from earth leakage.

Hazardous and sensitive industries like oil refineries / pulp

industries / electrical distribution etc., can be protected.

Complete protection for control engineering and mining

industry.

Applications:

PC

/IE

LR

/V7/1

017

10sA

CBCT Specification

Input Range : 300mA to 12A Default, 30mA - 1.0A (Optional)

CBCT: Tape Wound

Round Diameter: Inner Diameter 40mm, 60mm, 100mm,

150mm, 200mm, 250mm, 300mm

Rectangular: 150×50mm, 250×100mm, 300×100mm,

350×100mm, 400×125mm, 400×200mm, 500×225mm,

500×200mm. (Any other sizes subject to availability)

Technical Specification:

Specification Description

Accuracy: Class 2.0FS for dimension upto 200mm, Class 5.0 FS above 200mm

Input voltage: 80 - 300 V AC / DC.

Input current: Programmable 300mA - 12A.

Tripping time: Programmable 0.3 sec to 30 sec (Optional 30 mA - 1A).

Core Balance: CT type : tape wound

CBCT:

Relay contacts:

Contact Rating:

One pair of potential free NO & NC contacts.

Mounting Type: Flush.

Communication: RS 485 serial channel connection industry standard Modbus

RTU protocol.

Baud rate: 4800 bps to 19200 bps. (Preferred 9600 bps).

Isolation: 2000 volts AC isolation for 1 minute between

communication and other circuits.

Round - tape wound (Epoxy dipped option),

Rectangular - tape wound.

2Amps @ 240V AC / 24V DC.Core Balance Current Transformer - CBCT

Dimension Bezel: 96 x 96 mm (Depth 50mm behind Bezel)

90 mm

90 m

m

Panel

Clamp

Mechanical Specification:

90 m

m

96 m

m

50 mm Panel Cutout

Panel Cutout:+2 +290 x 90 mm-0 -0

Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters

| Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input

Output | Transducers | Converters

Sales Offices: BANGALORE | CHENNAI | MUMBAI | DELHI | HYDERABAD | USA | UAE

HO & Unit-I:

Plot No.: 47-P, Hardware Park, KIADB,

Huvinayakanahalli, Jala Hobli, Yelahanka Taluk,

Bengaluru - 562149 Karnataka INDIA.

E: [email protected]

Unit-II:

Goutham Garden, No. 4, Veerapandi,

Coimbatore - 641019 Tamilnadu INDIA

T: 0422 2697200 TF: 0244 2695200

E: [email protected]

Unit-III:

#764, 4th Phase, 707, Yelahanka New Town,

Bengaluru - 560 064 Karnataka INDIA

T: +91 80 28461744

E: [email protected]

ELMEASURE INDIA PRIVATE LIMITED

Input Frequency: 45 65 Hz

ECO friendly lead free 18 months warranty

Page 25: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

MOTOR PROTECTION

SYSTEM

MPS & MPU

www.elmeasure.com

ONE STOP SOLUTION

FOR MOTOR PROTECTION!

Voltage | Overload | Frequency | PF | Single phasing | Unbalance

loading of voltage and current | Neutral current | Phase reversal.

TRIP

UNSAFESAFE ALARM TRIP

MOTOR PROTECTION SYSTEM

MPS 8000

T1CLR PRGRESET

TRIP

TRIP

TRIP

SAFE

MOTOR PROTECTION UNIT

V - A - Hz - W - VA - PF - Wh

LG 5 1 10+MPU 5 1 10

REV OLD TRIP

T 1

PRG

RESET

Contact for certification details

www.powercorporation.in

Page 26: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

Common Features: Technical Specification:

Specification Description

Accuracy:

Sensing/

Measurement:

True RMS, 1 Sec update time.

Input Voltage: 4 Voltage inputs (VR, VY, VB, VN); Programmable 110 or 415V LL

Nominal (Range 80-550V LL)Primary Programmable up to 999 kV

Burden: 0.2VA Max. per phase.

Input Current: Current inputs (AR, AY, AB) 50mA - 6A (Field configurable 1A or 5A)

Primary Programmable up to 99 kA

Overload: 10A max continuous, 50A max for 3 sec.

Burden: 0.2VA Max. per phase.

Aux-Supply

(control power):

(Control Power): 80 - 300V AC/DC.

CT PT Ratio Max: 2000 MVA Programmable.

Operational diagram for MPS & MPU

User programmable password protection.

Auto-scaling of Kilo, Mega, Giga and decimal point.

Auto scrolling.

Finger touch proof terminals for voltage and current

connections.

Clearance & creepage distance meets UL 61010 safety

standard.

Communication with PCs, PLCs, DCS through optional RS

485/232 serial interface.

Potential free output with programmable trip time for

protection.

Displays more than 25 parameters Basic (VLL, VLN, A, Hz);

Power (W, VA, PF) and Energy (kW, Load Hours).

Displays the reasons for tripping for future correction.

Programmable start time from sensing safe condition.

Programmable locked rotor current and time.

Weight: Unpacked: 300 gms, Packed: 400 gms

Parameters can be configured and its range : Parameters Default Setup Default Setup Range

MPU 5110 MPS 8000

Connection mode(ELEMNT) STAR STAR STAR/ DELTA

PT Primary (PT.Pri) 415.0 415.0 100V - 999kV

PT Secondary (PT SEC) 415.0 415.0 50V - 550V

CT Primary (CT.Pri) 5.000 5.000 0.5A - 99kA

CT Secondary (CT SEC) 5.000 5.000 0.5A - 6A

VA selection (UA.SLEC) Arith Vec.H

(Arithmetic) (Vector)

Over Voltage Line to Line 550.0 550.0 1.000 - 999kV

Under Voltage Line to Line 10.00 0.001 0.001 - 999kV

Under Current (Dry Run) 0.200 NA 0 - 99kA

Over Current 6.0 6.0 0.500 - 99kA

Over Frequency NA 60.00 25 - 200

Under Frequency NA 40.00 25 - 200

Under PF NA 0.400 0.001 - 0.999PF

Percentage Voltage Unbalance NA 7.000% 0.5 - 60%

Percentage Current Unbalance NA 7.000% 0.5 - 60%

Neutral Current NA 2.000 0.030 - 99kA

ON Delay 5.00 10.00 1 - 600 Sec

OFF Delay 5.00 3.000 1- 60 Sec

Motor ON safe status NA RELAY ON REL ON/ OFF

Locked Rotor Current 6 time fixed 30.00 1 - 999kA

(not programmable)

Locked Rotor Time Delay NA 5.00 1 - 60 Sec

Winding Short NA 10% 5 - 90%

Over Current Digital Output Absolute INV CUrV INV CUrV/Absolute

Characteristics

Poles NA 4.000 1 - 28 Poles

Reverse Lock No No NO / YES

Communication: Rs485 serial interface Industry standard Modbus RTU protocol

(RS232 optional)

Baud rate: 4800 bps to 19200 bps. (Preferred 9600 bps)

Isolation: 2000 volts AC isolation for 1 minute between

communication and other circuits.Displays ON hours , Load hours & number of interruption.

Simultaneous display of 7 parameters.

Intelligent power save mode.

Two field configurable parameter for continuous display.

Continuous Wh display even in Auto-scrolling mode.

Graphical display.

Neutral current display and protection.

Single solutions for protection of motors/equipment against

voltage, overload, frequency, PF, single phasing, unbalance

loading of voltage and current, neutral current, & phase

reversal.

Programmable (intelligent inverse time) trip time for

Volts/Overload/Hz/PF/Neutral current.

Programmable relay status High or Low for safe; 2 relays for

alarm and trip.

Detect winding shorts.

Safe/Alarm/Trip indication for on line view.

Manual re-correction after the trip.

Measures VLL, VLN, A, Hz, W, VA, PF, Neutral current, Wh,

Load hours, ON hours, No. of interruption.

Additional Features for MPS 8000:

TRIP

Load Pattern

SAFE REGIONTRIP

Sta

rt D

ela

yPr

og

ram

ma

ble

Programmable Relay Status

UNSAFE REGION

Time

Ala

rm R

ela

yfo

r W

arn

ing

Intelligent tripping based on load

Off time

Para

me

ter

like

un

de

r/o

ver

Volts

,A

mp

s, F

req

ue

nc

y, P

F, U

nb

ala

nc

elo

ad

ing

of Vo

ltag

e/C

urr

en

t, N

eutra

l curr

en

t, S

ing

le p

ha

sin

g

OFF TIMEVariable

TRIP

Load Pattern

SAFE REGIONTRIP

Sta

rt D

ela

yPr

og

ram

ma

ble

UNSAFE REGION

Time

Off time

Para

me

ter

like

un

de

r/o

ver

Volts

,A

mp

s, D

ry r

un, Si

ng

le p

ha

sin

g

OFF TIMEVariable

MPS 8000

MPU 5110

Arith(Arithmetic)/Vector

vec.H(vector harmonics)

PC/M

PS/V5/1017

Class 1.0 (default) as per IEC 62053-21, Class 0.5 as per

IEC 62053-22 (Optional).

Input Frequency: 45 - 65 Hz

ECO friendly lead free 18 months warranty

Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters

| Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input

Output | Transducers | Converters

Sales Offices: BANGALORE | CHENNAI | COIMBATORE | MUMBAI | DELHI | HYDERABAD | USA | UAE

HO & Unit-I:

Plot No.: 47-P, Hardware Park, KIADB,

Huvinayakanahalli, Jala Hobli, Yelahanka Taluk,

Bengaluru - 562149 Karnataka INDIA.

E: [email protected]

Unit-II:

Goutham Garden, No. 4, Veerapandi,

Coimbatore - 641019 Tamilnadu INDIA

T: 0422 2697200 TF: 0244 2695200

E: [email protected]

Unit-III:

#764, 4th Phase, 707, Yelahanka New Town,

Bengaluru - 560 064 Karnataka INDIA

T: +91 80 28461744

E: [email protected]

ELMEASURE INDIA PRIVATE LIMITED

Page 27: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

PORTABLE POWER ANALYSER

CUM DATA LOGGER

iD - LOG

www.elmeasure.com

High Profile Portable Power

Analyzer with Higher Accuracy

and Data logging

USER FRIENDLY | DYNAMIC COMMUNICATION | DEMAND MONITORING

www.powercorporation.in

Page 28: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

A variety of reports can be availed by activity, schedule and

types by specific list:

Data Quality

Exception Reports

Alarm Handling Packages

Display Groups

Historical Data Trending

Real time Trending

Dashboard

Matrix

Reports can be viable and downloaded by any format provided

and schedules can be modified based on convenient time.

*Schedulers will automatically run according to our initial

configuration

Analyzing and Reporting

The Software collects data from the plant

consolidating it into manageable information to

constantly monitor energy usage and identify the core

areas for corrective action, ensuring optimum

performance.

ElNetEnergy Management Software

Web based technology

User friendly

Enhanced security

Vector based graphics

Remote monitor and control equipment processes and

facilities with in-expensive web browsers

Report on operational status of equipment, process and

facilities

Reduce billing cycles by obtaining accounting information

directly from automation systems

Reduce service calls and manpower by using remote

diagnostics.

Use low cost secure connections to network over a

combination if ISP, Intranet, Internet and dial-up

connections

Email/SMS

Day Log book, Hourly-day Energy, Shift Energy, TOD

energy, Min max, Flexible energy report and for

abnormal Alarm conditions

SMS to the mobile for the following: abnormal Alarm

conditions, Hourly and Daily Energy

Customization is possible for any kind of Email/SMS

options

Applications

Frontline troubleshooting

Predictive maintenance

Quality of service compliance

Long-term analysis

Load studies

Energy assessments

24/7 CLOUD SERVER

Datalog

Trends - Single and multiple days Min, Max & Avg.

Table view - Single and multiple days Data Export to Excel

Alarm, Min & Max.

iD LOGGER Portable Power Analyser with Dynamic Communication,

Higher Accuracy and Data Logging

Portability

Compact Size

Modular Construction

LCD Screen

Inbuilt GPRS Communication

DATA LOGGER

iD-LOG 7700OPTION BASIC POWER ENERGY

iD LOG - Ethernet

4GB data logger (default)

Option for current measurement using

Clip CT (default) or Rogowski

iD LOG - Ethernet & GPRS

14GB data logger (default)

Kit - 1

Kit - 2

Internet

Helps you to locate, predict, prevent and troubleshoot problems in power

distribution.

Measures voltage, current, frequency, power, energy consumption, unbalance,

harmonics and inter-harmonics.

24x7 Cloud Server Data logging with Time stamp

Monitor and Control large campuses or remote facilities with inexpensive web

technology

Perform audits and analyses remotely.

Features

Benefits

Maximum Return on Investments

Reduce Energy Costs

Improve Working Environment

Identification and elimination of energy waste

Security and System Integration

Various Protocol Supported

Economically priced

High Performance and Easy configuration

Page 29: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

Features Parameters

Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters | Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input Output | Transducers | Converters

Sales Offices: BANGALORE | CHENNAI | MUMBAI | DELHI | HYDERABAD | USA | UAE

HO & Unit-I:

Plot No.: 47-P, Hardware Park, KIADB, Huvinayakanahalli, Jala Hobli, Yelahanka Taluk, Bengaluru - 562149 Karnataka INDIA.E: [email protected]

Unit-II:

Goutham Garden, No. 4, Veerapandi, Coimbatore - 641019 Tamilnadu INDIAT: 0422 2697200 TF: 0244 2695200E: [email protected]

Unit-III:

#764, 4th Phase, 707, Yelahanka New Town, Bengaluru - 560 064 Karnataka INDIAT: +91 80 28461744E: [email protected]

ELMEASURE INDIA PRIVATE LIMITED

Specifica�on Descrip�on

Technical Specifica�on:

Accuracy:

Sensing/

Measurement:

Input voltage:

Input frequency:

Input current:

Aux-Supply:

Display Type:

Display Resolution:

CT PT Ratio Max:

Communication:

Class 1 (Default) ,IEC 62053-21

Class 0.2 with specific CT.

True RMS, 1 Sec update time.4 Quadrant

Power & Energy

4 Voltage inputs (VR, VY, VB, VN)

Programmable 110 or 415V LL Nominal

(Range 80 to 520 VLL) Primary

Programmable up to 999 kV. Burden:

0.2VA Max. per phase.

45 Hz to 65 Hz

Current inputs (333mV)

Primary Programmable up to 99 kA.

Burden: 0.2VA Max. per phase.

Built-in

6mm height bright LCD graphical display.

7 digits.

2000 MVA Programmable.

GPRS / Ethernet

} Programmable sliding/fixed window, block demand period, forcast/step demand control

Basic

Line to Neutral Voltage VLN Avg,VR-N,VY-N,VB-N

Line to Line Voltage VLL Avg,VR-Y,VY-B,VB-R

Line Current AR, AY, AB, A-avg

Neutral Current Computed AN

Frequency, RPM (Generator application) Hz, RPM

V & A Phase Angle VR, VY, VB, AR, AY, AB

Unbalance V & A % V, % A, VR, VY, VB, AR, AY, AB

Power

Active Power W Total, WR, WY, WB

Apparent Power VA Total, VAR, VAY, VAB

Reactive Power VAR Total, VAR R, VAR Y, VAR B

Power Factor PF Avg, PFR, PFY, PFB

Energy / Integrated

Active Energy Wh

Apparent Energy VAh

Reactive Energy VARh-Ind, VARh-Cap

Load Hrs, No. of Interruption, Life Timer LH, Intr, On.Hr Ah, PF Avg

Old (Energy, Load Hrs) Old (Wh, VAh, VARh Ind/Cap, LH)

Harmonics

Voltage THD THD% VR, VY, VB

Current THD THD% AR, AY, AB

K Factor K Factor: VR, VY, VB, AR, AY, AB

Individual Harmonics Upto 31st (V & A)

Events (High/Low)/ With time stamp

Voltage VLL, VLN High/Low VLL, VLN

Current High/Low A

Frequency High/Low Hz

VA High/Low VA

W High/Low W

VAR High/Low VAR

Power Factor High/Low PF

Demand Programmable to any one of the below

Active Power (W) Watt

Apparent Power (VA) VA

Reactive Power (VAR) VAR

Current Average (A.Avg) A Avg

Suitable to measure current from mA to hundreds of kA.

High linearity | Wide range | Non-intrusive, no power drawn from the main.

Very useful with large size or awkward shaped conductors or in places with limited access.

No danger from open-circuited secondary | Not damaged by large overloads.

CT Specification

Clip CT

333 mV

Input current 250A

Rogowski coil

Rated Current: 100A ~ 100 kA

Output: 0.333V or 100mV per 1000A

Diameter: 24 cm, 36 cm

Lead wire: 1.5 m length

Isolation voltage: 3500Vo oTemperature range: -25 C + 70 C

Response bandwidth: 1Hz ~ 1MHz

Page 30: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

INTELLIGENT

POWER FACTOR CONTROLLER

iPFC

Contact for certification details

www.elmeasure.com

INTELLIGENT DEVICE TO

MAINTAIN THE POWER FACTOR

IN REQUIRED RANGE

Current | Voltage | Frequency | PF | VAR | 6/8/12 stage control

www.powercorporation.in

Page 31: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

PC

/IP

CF

/V6/1

017

Three phase sensing.

Intelligent Power Factor Controlling based on the capacitor

bank switching history (Number of operations, ON time)

improves the capacitor life time.

6 or 8 or 12 switching relay outputs.

Automatic or manual control (manual control with power

backup option).

User programmable:

- Star/Delta.

- Lead and Lag limits.

- PT and CT ratios.

- CT secondary.

- Minimum switch ON time (4-999 seconds).

- Minimum discharge time (4-999 seconds).

- Minimum capacitor on time (4-999 seconds).

- Minimum sensing current for controlling operation

100mA - 500mA.

- User programmable capacitor value.

Fault detection (Over compensation, Under compensation,

Over voltage, Over current, Under voltage, Under current,

Over harmonics for voltage and current).

Displays VLL, VLN, Amps (Average and Phasewise) Frequency,

W, PF, VAR(Total and Phasewise) Wh,PF Avg.

Four quadrant operation.

RS 485 communication interface (Optional).

Features:

Technical Specification:

Specification Description

Accuracy:

Sensing/

Measurement:

Input voltage:

Applications:

Advantages

In all Incomers.

Fixed power factor corrections individual (e.g. motor,

transformers, lighting, etc.)

Group fixed power factor correction (several equipments

connected in a group).

Capacitor banks of tuned and detuned.

Harmonic trap applications (e.g. UPS, Frequency Drives

and Converters, etc.)

Three phase sensing gives accurate measurement of PF.

Fault Detection (Over compensation, Under compensation,

Over voltage, Over current, Under voltage, Under Current,

Over harmonics for voltage and current).

Automatic or Manual Control (manual control with power

backup option).

Increased capacitor life - capacitor switching based on

history - ON time / number of switching.

Dimension Bezel: 96 x 96 mm (Depth 50mm behind Bezel)

90 mm

90 m

m

Panel

Clamp

Mechanical Specification:

90 m

m

96 m

m

50 mm

4 Voltage inputs (VR, VY, VB, VN) Programmable 110 or 415V LL

Nominal (Range 80 to 550V LL) Primary Programmable up to

999 kV. Burden: 0.2VA Max. per phase.

Input current: Current inputs (AR, AY, AB) 50mA - 6A (Field configurable

1A or 5A). Primary Programmable up to 99 kA.

Overload: 10A max continuous, 50A max for 3 Sec.

Burden: 0.2VA Max. per phase.

Aux-Supply : (Control Power): 180 - 300V AC/DC, 40-70Hz.

Burden: 10VA Max.

Display Resolution: 1 row, 6 digits, (Integrated 6 digits) 10mm.

CT PT Ratio Max: 2000 MVA Programmable.

Communication: Master to PC.

RS485 serial channel connection, Industry standard Modbus

RTU protocol (RS232 optional).

Baud rate: 4800 bps to 19200 bps (Preferred 9600 bps).

Isolation: 2000 volts AC isolation for 1 minute between

communication and other circuits.

Contact rating: SPST, 2A @ 240V.

Weight: Unpacked: 350 gms, Packed: 450 gms.

True RMS, 1 Sec update time. 4 Quadrant Power & Energy.

NVB

VY

VR

AB

AY

AUX

AR

S1

S2

S1

S2

S1

S2

S1 S2

S1 S2

S1 S2

RY

BN

LOADRECEIVEDDELIVEREDLINE

RS

48

5

COM

1 2 3 4 5 6 7 8 9 10 11 12

LOAD

ALA

RM COM

1

Connection Scheme:

Note: Additional error of 0.1% of full scale, for meter input current below 500mA

Class 1.0 (default) as per IEC 62053-21, Class 0.5 as per

IEC 62053-22 (Optional).

Input Frequency: 45 65 Hz

ECO friendly lead free 18 months warranty

Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters

| Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input

Output | Transducers | Converters

Sales Offices: BANGALORE | CHENNAI | COIMBATORE | MUMBAI | DELHI | HYDERABAD | USA | UAE

HO & Unit-I:

Plot No.: 47-P, Hardware Park, KIADB,

Huvinayakanahalli, Jala Hobli, Yelahanka Taluk,

Bengaluru - 562149 Karnataka INDIA.

E: [email protected]

Unit-II:

Goutham Garden, No. 4, Veerapandi,

Coimbatore - 641019 Tamilnadu INDIA

T: 0422 2697200 TF: 0244 2695200

E: [email protected]

Unit-III:

#764, 4th Phase, 707, Yelahanka New Town,

Bengaluru - 560 064 Karnataka INDIA

T: +91 80 28461744

E: [email protected]

ELMEASURE INDIA PRIVATE LIMITED

Page 32: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

SMART I/O

www.elmeasure.com

SMARTEST WAY TO CAPTURE

THE INPUT & COMMUNICATE

DATA OUTPUT!

Universal Input | Universal Output | Digital Output

SMART INPUT & OUTPUT

MODULE

www.powercorporation.in

Page 33: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

PC

/SI-

O/V

3/1

017

Up to 8 Universal Inputs field configurable

Up to 4 Universal Outputs field configurable

6 SSR outputs and 2 relay outputs (optional)

Communication LON / RS 485

Fire resistant enclosure

Pluggable terminal blocks, for installation wiring and ease

of maintenance

UO

-CH

1

UO

-CO

M

UO

-CH

2

UO

-CH

3

UO

-CO

M

UO

-CH

4

DO

1

CO

M1

DO

2

CO

M2

DO

3

CO

M3

DO

4

CO

M4

DO

5

CO

M5

DO

6

DO

7

CO

M7-8

DO

8

AU

X2

AU

X1

CO

M

UI-

CH

8

LO

N-

LO

N+

LO

N-

LO

N+

UI-

CH

1

CO

M

UI-

CH

2

UI-

CH

3

CO

M

UI-

CH

4

UI-

CH

5

CO

M

UI-

CH

6

UI-

CH

7

CO

M6

+

GN

D

-

AUXUniversal Output

UO

1

UO

2

G OP

UO

3

UO

4

G OP

DO1+

DO2+

DO3 DO4 DO5 DO6+ + + +

DO7 DO8+ +

Digital Output

UI1

UI2

CO

M

UI3

UI4

CO

M

Universal Input

UI5

UI6

CO

M

UI7

UI8

CO

M

A B A B

12 - 36V AC/DC

G +

Wiring Diagram:

Configuration Software

Models Available UI / DI

SIO 9000 -1

SIO 9000 -2

SIO 9000 -3

8

8

8

DO

8

6

8

UO

4

2

0

SIO 9000 - 4 A 16DI 24V

SIO 9000 - 4 B 16DI PFC

Features:

Specification Description

Technical Specification:

Voltage

Consumption

Protection

13-28VAC, 50 / 60 Hz, 12-36V DC

1A max

Under voltage, over voltage (Max 40V), over current, reverse voltage

Universal Input

Digital

Voltage

Current

RTD

Thermistor

User defined

Accuracy Class

5V to 24V

0 to 5V, 0 to 10 VDC

4 to 20 mA, 0 to 20 mA factory set for loop powered

PT 100 (2 wire )

Thermistor 10K (Type 2) (Type 3 Optional)

1%+-

00.8 C+-

00.8 C+-

1%+-

Non standard 10K Potentiometer ->

temperature curve up to 60 points, user configurable transition table

up to 16 points

2/4 Universal Output (configurable only at factory)

Digital 0 or 12VDC, 60mA, RL 200 ohm

Voltage

Current

PWM

One Shot Pulse

0 to 10 VDC

4 to 20 mA, 0 to 20 mA (optional)

Configurable period 1 - 999 seconds (programmable on time and duty)

Configurable pulse width 100 ms to 1000 ms

2 - 8 SSR output (Configurable only at factory)

PWM

One Shot Pulse

Digital (Dry/Wet

Contact)

0 OR 24V @100mA

Configurable period 1 - 999 seconds

Configurable pulse width 100 ms - 1000 ms

Communication

Lon Talk TP/FT - 10

Mechanical

Enclosure Poly Carbonate

Environmental

LONMARK

CE Mark

Operating Temperature

Storage Temperature

Relative humidity

Connector

-10 °C to +55 °C

-25 °C to +70 °C

51

2 Part pluggable

5 to 95 % (Non-condensing)

Mod Bus RS 485

Isolation RS 485 - 5 KV, LON - Polarity free

Flammability class UL94-V0 (non-flammable)

Dimensions 145x90x 45(LxBXH)

Mounting DIN rail / wall mounting

Weight 300 gm

Compliance

CO2

Pressure

Sensor

CO2 Flow

Sensor

Level

Sensor

Humidity

Sensor

Occupancy

Sensor

LON

Fan

A/C Lighting

Pump

Chiller

VAV’s

Boiler

MODBUS

UI1

UI2

CO

M

UI3

UI4

CO

M

Universal Input

UI5

UI6

CO

M

UI7

UI8

CO

M

A B A B G +

AUXUniversal Output

UO

1

UO

2

G OP

UO

3

UO

4

G OP

DO1+

DO2+

DO3 DO4 DO5 DO6+ + + +

DO7 DO8+ +

Digital Output

12 - 36V AC/DC

IP

Ordering Information :

Range of Products: Building Energy Management System (BEMS) | EMS | Demand Controller | Multifunction Meters | Electronic Energy Meters | Dual Energy Meter | Digital Panel Meters

| Automatic Changeover with Current Limiter (ACCL) |Power Factor Controller (PFC) | Earth Leakage Relay (ELR) | Earth Fault Relay (EFR) | Gateway | Branch Monitoring Unit | Smart Input

Output | Transducers | Converters

HO & Unit-I:

Plot No.: 47-P, Hardware Park, KIADB,

Huvinayakanahalli, Jala Hobli, Yelahanka Taluk,

Bengaluru - 562149 Karnataka INDIA.

E: [email protected]

Unit-II:

Goutham Garden, No. 4, Veerapandi,

Coimbatore - 641019 Tamilnadu INDIA

T: 0422 2697200 TF: 0244 2695200

E: [email protected]

Unit-III:

#764, 4th Phase, 707, Yelahanka New Town,

Bengaluru - 560 064 Karnataka INDIA

T: +91 80 28461744

E: [email protected]

ELMEASURE INDIA PRIVATE LIMITED

Sales Offices: BANGALORE | CHENNAI | COIMBATORE | MUMBAI | DELHI | HYDERABAD | USA | UAE

18 months warranty

ECO friendly lead free 18 months warranty

POWER CORPORATION302 Mayu Tower, Nr. Shyamal Row Houses, Satellite, Ahmedabad-380015email: [email protected], [email protected], [email protected]: www.powercorporation.in Mobile: 9376181613

Page 34: CM SMART BASIC METERS/ TRANSDUCERS/DC ... - Power …

POWER CORPORATION302 Mayu Tower, Nr. Shyamal Row Houses, Satellite, Ahmedabad-380015email: [email protected], [email protected], [email protected]: www.powercorporation.in Mobile: 9376181613