climatic test report kfm21 e - · pdf filekfm21_e test report no. 200011.001internal e00680.00...

23
KFM21_e Test Report No. 200011.001internal E00680.00 Status: 30.05.2003 Page 1 from 23 © Kontron Elektronik GmbH All rights reserved CLIMATIC Test Report ONLY FOR THE INTERNAL APPLICATION No. 200011.001internal for KFM 21_e Test Laboratory: Kontron Elektronik GmbH Oskar von Miller Straße 1 85386 Eching Germany Applicant: Kontron Embedded Computers AG Purpose of Testing: To show compliance with IEC 60068 PT2-1 IEC 60068 PT2-2 IEC 60068 PT2-14 IEC 60068 PT2-30 Special Measurement: none (see section "Reference Standards" for identical national standards) Note: The test data of this report relate only to the individual item tested. This report must not be reproduced unless explicitly approved by Kontron Embedded Computers AG.

Upload: truongngoc

Post on 06-Feb-2018

216 views

Category:

Documents


1 download

TRANSCRIPT

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 1 from 23 © Kontron Elektronik GmbH All rights reserved

CLIMATIC Test Report ONLY FOR THE INTERNAL APPLICATION

No. 200011.001internal for KFM 21_e

Test Laboratory: Kontron Elektronik GmbH

Oskar von Miller Straße 1 85386 Eching Germany

Applicant: Kontron Embedded Computers AG

Purpose of Testing: To show compliance with

IEC 60068 PT2-1

IEC 60068 PT2-2

IEC 60068 PT2-14

IEC 60068 PT2-30

Special Measurement: none

(see section "Reference Standards" for identical national standards)

Note:

The test data of this report relate only to the individual item tested.

This report must not be reproduced unless explicitly approved by Kontron Embedded

Computers AG.

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 2 from 23 © Kontron Elektronik GmbH All rights reserved

Table of Contents

1. Administrative Data ..............................................................................................4

2. Summary of Test Results ....................................................................................5

3. Data of Operation Mode and Configuration of EUT........................................6 3.1 Operation Mode ......................................................................................6

3.2 Configuration of Cables of EUT ...........................................................6

3.3 Configuration of EUT..............................................................................6

3.4 Configuration of Peripherals of EUT....................................................6

4. Performed Tests and Results .............................................................................7

5. Annotations to Performed Tests and to CE certification ................................8 5.1 The Test in the Climatic Chamber .......................................................8

5.2 Basic environmental testing procedures .............................................9

6. Referenced Regulations ....................................................................................10

7. List of Test Equipment .......................................................................................11

8. Photographs of EUT and Test Setup ..............................................................12

9. Climatic conditions to IEC 60068 .....................................................................13

10. Temperature measurement ..............................................................................15 10.1 Layout : Temperature sensors KFM21_e .........................................16

11. Temperature diagrams ......................................................................................17 11.1 IEC 60068 PT2-2 Non Operating .......................................................17

11.2 IEC 60068 PT2-1 Non Operating and ...............................................17

11.3 IEC 60068 PT2-30 Non Operating .....................................................17

11.4 IEC 68-2-1 Operating ...........................................................................18

11.5 IEC 68-2-2 Operating ...........................................................................19

11.6 IEC 68-2-14 Operating .........................................................................20

11.7 IEC 68-2-14 Non Operating ................................................................21

12. Reference Standards .........................................................................................22

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 3 from 23 © Kontron Elektronik GmbH All rights reserved

Table of Pictures

Picture 1: Stabilizing period ......................................................................................

Picture 2: Test Db – test cycle ................................................................................9

Picture 3: Recovery at controlled conditions ........................................................9

Picture 4 : IEC Climatic Chamber .........................................................................12

Picture 5: IEC 60068 PT2-2 Test Bb: Dry heat for non-heat-dissipating specimen with gradual change of temperature................................13

Picture 6: IEC 60068 PT2-14 Test Nb: Change of temperature with specified rate of change ......................................................................13

Picture 7: IEC 60068 PT2-1 Test Ab: Cold for non heat-dissipating specimen with gradual change of temperature................................14

Picture 8: IEC 60068 PT2-30,Test Db: 12+12 Hour Cycle .............................14

Picture 9: Mounting positions of the temperature sensors...............................16

Picture 10: Diagram of IEC 68-2-1 operating measurement .............................18

Picture 11: Diagram of IEC 68-2-2 operating measurement .............................19

Picture 12: Diagram of IEC 68-2-14 operating measurement ...........................20

Picture 13: Diagram of IEC 68-2-14 non operating measurement ...................21

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 4 from 23 © Kontron Elektronik GmbH All rights reserved

1. Administrative Data

Equipment under test: KFM21_e

optional Equipment under test:

Options/accessories: None

Serial number: 137868003

Version of EUT:

Applicant (full address): Kontron Elektronik GmbH

Contract identification: none

Contact person: none

Manufacturer: Kontron Elektronik GmbH

Receipt of EUT: 12/07/2002

Date of test: 12/07/2002

Date of report 24/07/2002

Tested by: Karlheinz Schiege Robert Hölzl

Test report by: Karlheinz Schiege Robert Hölzl Ralf J. Wagner

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 5 from 23 © Kontron Elektronik GmbH All rights reserved

2. Summary of Test Results

The tested sample fully complies with the requirements set forth in

IEC 60068 PT2-1

IEC 60068 PT2-2

IEC 60068 PT2-14

IEC 60068 PT2-30

(see section "Reference Standards" for identical national standards)

Ralf J. Wagner Ralf J. Wagner Robert Hölzl

Technical Manager Test Engineer

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 6 from 23 © Kontron Elektronik GmbH All rights reserved

3. Data of Operation Mode and Configuration of EUT

3.1 Operation Mode

Special Susceptibility tests: Windows Screen Saver

Susceptibility tests: none

3.2 Configuration of Cables of EUT

3.3 Configuration of EUT

Display Samsung 21,3'' UXGA LTM213U3-L07

Backlight-Inverter Samsung SK2400H für LTM213U3-L07

Power supply Bicker SNP-Z107

Receiver Distec Prisma I (UXGA)

Power filter Schaffner FN321-1/05

Operating-System 1 MS WIN 98

3.4 Configuration of Peripherals of EUT

Channel Multiplexer 8 Channel

Keyboard: Cherry

Mouse: none

Configuration optional none

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 7 from 23 © Kontron Elektronik GmbH All rights reserved

4. Performed Tests and Results

Test Classification/Result Note

IEC 60068 PT2 -1 The requirements are fulfilled No degradation or loss of function or performance.

IEC 60068 PT2 -2 The requirements are fulfilled No degradation or loss of function or performance.

IEC 60068 PT2 -14 The requirements are fulfilled No degradation or loss of function or performance.

IEC 60068 PT2 -30 The requirements are fulfilled No degradation or loss of function or performance.

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 8 from 23 © Kontron Elektronik GmbH All rights reserved

5. Annotations to Performed Tests and to CE certification

5.1 The Test in the Climatic Chamber

Climatic chamber

Damp, Heat, Cold CyclicChamber Control

Computer Agilent 20 Channel

Multiplexer

(Test value recording)

Powersupply

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 9 from 23 © Kontron Elektronik GmbH All rights reserved

5.2 Basic environmental testing procedures

Test Db and guidance - damp heat, cyclic 12+12 HOUR

CYCLE (IEC 60068 PT2-30)

The object of the test is to determine the suitability of components, equipment or other articles for use and/or storage under conditions of high humidity when combined with cyclic temperature changes. This test replaces the original Test D in the Publication 68-2-4 for future applications (the parameters takes from the page 14)

Picture 1: Stabilizing period Picture 2: Test Db – test cycle

Picture 3: Recovery at controlled conditions

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 10 from 23 © Kontron Elektronik GmbH All rights reserved

6. Referenced Regulations

(see section "Reference Standards" for identical national standards) Regulation Comment

IEC 60068 PT2 -1 :1994

ENVIRONMENTAL TESTING - TESTS A: COLD

Concerns cold tests on both non-heat-dissipating and heat-dissipating specimens.

IEC 60068 PT2 -2

:1994

EN 60068 PT2-2 :1993

ENVIRONMENTAL TESTING - TESTS B: DRY HEAT

Contains Test Ba: Dry heat for non-heat-dissipating specimen with sudden change of temperature; Test Bb: Dry heat for non-heat-dissipating specimen with gradual change of temperature; Test Bc: Dry heat for heat-dissipating specimen with sudden change of temperature; Test Bd: Dry heat for heat-dissipating specimen with gradual change of temperature. The 1987 reprint includes IEC No. 62-2-2A.

IEC 60068 PT2 -14

:1984

EN 60068-2-14 :1999

ENVIRONMENTAL TESTING - PART 2-14 - TESTS - TEST N - CHANGE OF TEMPERATURE

Determines the ability of components, equipment and other articles to withstand rapid changes of ambient temperature. The exposure times to accomplish this depend upon the nature of the specimen.

IEC 60068 PT2 -30

:1980

EN 60068-2-30 :1999

BASIC ENVIRONMENTAL TESTING PROCEDURES - TEST DB AND GUIDANCE - DAMP HEAT, CYCLIC (12+12 HOUR CYCLE)

Determines the suitability of components, equipment and other articles for use and/or storage under conditions of high humidity when combined with cyclic temperature changes.

Special standard

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 11 from 23 © Kontron Elektronik GmbH All rights reserved

7. List of Test Equipment

Equipment Type Model Equipment No. Calibration valid until

Manufacturer

P Climatic Chamber VUK 04-500 PM-EM-6160-1 08.99 Heraus-Vötsch

P Control computer IPLite Color PM-EM-9599.01 not requested Kontron Elektronik

P Measuring system 34970A PM-EM-9519.01 not requested HP/Agilent

P Control computer Rx7000 PM-EM-9597.01 not requested Kontron Elektronik

P (check mark in 1st column) = tested with

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 12 from 23 © Kontron Elektronik GmbH All rights reserved

8. Photographs of EUT and Test Setup

Picture 4 : IEC Climatic Chamber

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 13 from 23 © Kontron Elektronik GmbH All rights reserved

9. Climatic conditions to IEC 60068

Time (Min.)

Humidity % Temperatur ° C

20 M i n .

60 Min . 180 Min .

200 Min.

rel. 20%

rel. 50%

21°C

55°C

Picture 5: IEC 60068 PT2-2 Test Bb:

Dry heat for non-heat-dissipating specimen with gradual change of temperature

0%

55%

Temperatur °C rel.Humidity %

TA=0°C

TB=60°C

21°C

Time (Min.) 0 20 90 210 270 390 510 630 690 Picture 6: IEC 60068 PT2-14 Test Nb:

Change of temperature with specified rate of change

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 14 from 23 © Kontron Elektronik GmbH All rights reserved

0%

55%

Temperatur °C rel.Humidity %

TA=0°C

21°C

Time (Min.) 0 30 90 210 270

Picture 7: IEC 60068 PT2-1 Test Ab:

Cold for non heat-dissipating specimen with gradual change of temperature

Temperatur °C rel.Humidity %

TA= 25°C

Ta 55°C

Time (h)

95%

60%

90%

24h

3 9 3 9 0

Picture 8: IEC 60068 PT2-30,Test Db:

12+12 Hour Cycle

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 15 from 23 © Kontron Elektronik GmbH All rights reserved

10. Temperature measurement

Inquiry of the temperature limits at temperature critical components.

Chosen critical components:

• Display Backside

• Controllerchip

• Power supply

• Backlight inverter

• System

• Ambient

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 16 from 23 © Kontron Elektronik GmbH All rights reserved

10.1 Layout : Temperature sensors KFM21_e

Controllerchip

Powersupply

DisplayBackside

Controllerchip

Power SupplyUnit

System

BacklightinverterDisplayBackside

Ambient

Picture 9: Mounting positions of the temperature sensors

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 17 from 23 © Kontron Elektronik GmbH All rights reserved

11. Temperature diagrams

into dependence of the surroundings to IEC 60068

(temperature, atmospheric humidity)

11.1 IEC 60068 PT2-2 Non Operating

have been done, but without recording

11.2 IEC 60068 PT2-1 Non Operating and

have been done, but without recording

11.3 IEC 60068 PT2-30 Non Operating

have been done, but without recording

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 18 from 23 © Kontron Elektronik GmbH All rights reserved

11.4 IEC 68-2-1 Operating

-10,00

0,00

10,00

20,00

30,00

40,00

50,00

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280

Time (Min)

°C

PSU Backlight Display Controllerchip System Ambient

Picture 10: Diagram of IEC 68-2-1 operating measurement

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 19 from 23 © Kontron Elektronik GmbH All rights reserved

11.5 IEC 68-2-2 Operating

0,00

10,00

20,00

30,00

40,00

50,00

60,00

70,00

80,00

90,00

0 10 20 30 40 5 0 60 70 8 0 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270

Time (Min)

°C

PSU Backlight Display Controllerchip System Ambient

Picture 11: Diagram of IEC 68-2-2 operating measurement

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 20 from 23 © Kontron Elektronik GmbH All rights reserved

11.6 IEC 68-2-14 Operating

- 5 , 0 0

5 , 0 0

1 5 , 0 0

2 5 , 0 0

3 5 , 0 0

4 5 , 0 0

5 5 , 0 0

6 5 , 0 0

7 5 , 0 0

0 24 48 72 96 120

144

168

192

216

240

264

288

312

336

360

384

408

432

456

480

504

528

552

576

600

624

648

672

696

720

744

768

792

816

840

864

888

912

T i m e ( M i n )

°C

P S U B a c k l i g h t D isp lay Cont ro l le rch ip S y s t e m A m b i e n t

Picture 12: Diagram of IEC 68-2-14 operating measurement

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 21 from 23 © Kontron Elektronik GmbH All rights reserved

11.7 IEC 68-2-14 Non Operating

- 2 5 , 0 0

- 1 5 , 0 0

-5 ,00

5 , 0 0

1 5 , 0 0

2 5 , 0 0

3 5 , 0 0

4 5 , 0 0

5 5 , 0 0

6 5 , 0 0

0 40 80 120 160 200 240 280 320 360 400 440 480 520 560 600 640 680 720 760 800 840 880 920 960 1000

1040

1080

1120

1160

1200

1240

1280

1320

1360

1400

1440

T i m e ( M i n )

° C

P S U B a c k l i g h t D i s p l a y B a c k s i d e Con t ro l l e r ch ip S y s t e m A m b i e n t

Picture 13: Diagram of IEC 68-2-14 non operating measurement

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 22 from 23 © Kontron Elektronik GmbH All rights reserved

12. Reference Standards

Tested standard Reference Standard (identical/similar to)

IEC 60068 PT2 -1 Identical with: BS EN 60068 PT2-1 DIN EN 60068 PT2 -1 DIN IEC 68 PT2-1 EN 60068 PT2-1 HD 323.2.1 JIS-C0020 NEN 10068-2-1 NFC 20-701 NF EN 60068-2-1 SEN 43 16 01 SS EN 60068

IEC 60068 PT2 -2 Technical Equivalent to: AS 1099:PT2BA AS 1099:PT2BB AS 1099:PT2BC AS 1099:PT2BD JIS-C8938

Identical with: BS EN 60068 PT2-2 DIN EN 60068 PT2 -2 DIN IEC 68 PT2-2 EN 60068 PT2-2 HD 323.2.2 JIS-C0021 JIS C0039 NEN 10068-2-2 NFC 20-702 NF EN 60068-2-2 SEN 43 16 02 SS EN 60068

IEC 60068 PT2 -14 Technical Equivalent to: AS 1099:PT2N AS 1099:PT2NA AS 1099:PT2NB AS 1099:PT2NC DIN EN 60068-2-14 JIS-C0025

Identical with: BS 2011:PT2.1N(1985) BS EN 60068-2-14 DIN IEC 60068-2-14 DIN IEC 68 PT2-14 EN 60068-2-14 HD 323.2.14 NEN 10068-2-14 NEN EN IEC 60068-2-14 NFC 20-714 NF EN 60068-2-14 SEN 43 16 13 SS EN 60068

KFM21_e Test Report No. 200011.001internal

E00680.00 Status: 30.05.2003 Page 23 from 23 © Kontron Elektronik GmbH All rights reserved

Tested standard Reference Standard (identical/similar to)

IEC 60068 PT2 -30 Technical Equivalent to: AS 1099:PT2D JIS-C0027

Identical with: BS 2011:PT2.1DB(1981) BS EN 60068-2-30 DIN EN 60068-2-30 DIN IEC 60068-2-30 DIN IEC 68 PT2-30 EN 60068-2-30 HD 323.2.30 NEN 10068-2-30 NEN EN IEC 60068-2-30 NFC 20-730 SS EN 60068