KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 1 from 23 © Kontron Elektronik GmbH All rights reserved
CLIMATIC Test Report ONLY FOR THE INTERNAL APPLICATION
No. 200011.001internal for KFM 21_e
Test Laboratory: Kontron Elektronik GmbH
Oskar von Miller Straße 1 85386 Eching Germany
Applicant: Kontron Embedded Computers AG
Purpose of Testing: To show compliance with
IEC 60068 PT2-1
IEC 60068 PT2-2
IEC 60068 PT2-14
IEC 60068 PT2-30
Special Measurement: none
(see section "Reference Standards" for identical national standards)
Note:
The test data of this report relate only to the individual item tested.
This report must not be reproduced unless explicitly approved by Kontron Embedded
Computers AG.
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 2 from 23 © Kontron Elektronik GmbH All rights reserved
Table of Contents
1. Administrative Data ..............................................................................................4
2. Summary of Test Results ....................................................................................5
3. Data of Operation Mode and Configuration of EUT........................................6 3.1 Operation Mode ......................................................................................6
3.2 Configuration of Cables of EUT ...........................................................6
3.3 Configuration of EUT..............................................................................6
3.4 Configuration of Peripherals of EUT....................................................6
4. Performed Tests and Results .............................................................................7
5. Annotations to Performed Tests and to CE certification ................................8 5.1 The Test in the Climatic Chamber .......................................................8
5.2 Basic environmental testing procedures .............................................9
6. Referenced Regulations ....................................................................................10
7. List of Test Equipment .......................................................................................11
8. Photographs of EUT and Test Setup ..............................................................12
9. Climatic conditions to IEC 60068 .....................................................................13
10. Temperature measurement ..............................................................................15 10.1 Layout : Temperature sensors KFM21_e .........................................16
11. Temperature diagrams ......................................................................................17 11.1 IEC 60068 PT2-2 Non Operating .......................................................17
11.2 IEC 60068 PT2-1 Non Operating and ...............................................17
11.3 IEC 60068 PT2-30 Non Operating .....................................................17
11.4 IEC 68-2-1 Operating ...........................................................................18
11.5 IEC 68-2-2 Operating ...........................................................................19
11.6 IEC 68-2-14 Operating .........................................................................20
11.7 IEC 68-2-14 Non Operating ................................................................21
12. Reference Standards .........................................................................................22
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 3 from 23 © Kontron Elektronik GmbH All rights reserved
Table of Pictures
Picture 1: Stabilizing period ......................................................................................
Picture 2: Test Db – test cycle ................................................................................9
Picture 3: Recovery at controlled conditions ........................................................9
Picture 4 : IEC Climatic Chamber .........................................................................12
Picture 5: IEC 60068 PT2-2 Test Bb: Dry heat for non-heat-dissipating specimen with gradual change of temperature................................13
Picture 6: IEC 60068 PT2-14 Test Nb: Change of temperature with specified rate of change ......................................................................13
Picture 7: IEC 60068 PT2-1 Test Ab: Cold for non heat-dissipating specimen with gradual change of temperature................................14
Picture 8: IEC 60068 PT2-30,Test Db: 12+12 Hour Cycle .............................14
Picture 9: Mounting positions of the temperature sensors...............................16
Picture 10: Diagram of IEC 68-2-1 operating measurement .............................18
Picture 11: Diagram of IEC 68-2-2 operating measurement .............................19
Picture 12: Diagram of IEC 68-2-14 operating measurement ...........................20
Picture 13: Diagram of IEC 68-2-14 non operating measurement ...................21
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 4 from 23 © Kontron Elektronik GmbH All rights reserved
1. Administrative Data
Equipment under test: KFM21_e
optional Equipment under test:
Options/accessories: None
Serial number: 137868003
Version of EUT:
Applicant (full address): Kontron Elektronik GmbH
Contract identification: none
Contact person: none
Manufacturer: Kontron Elektronik GmbH
Receipt of EUT: 12/07/2002
Date of test: 12/07/2002
Date of report 24/07/2002
Tested by: Karlheinz Schiege Robert Hölzl
Test report by: Karlheinz Schiege Robert Hölzl Ralf J. Wagner
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 5 from 23 © Kontron Elektronik GmbH All rights reserved
2. Summary of Test Results
The tested sample fully complies with the requirements set forth in
IEC 60068 PT2-1
IEC 60068 PT2-2
IEC 60068 PT2-14
IEC 60068 PT2-30
(see section "Reference Standards" for identical national standards)
Ralf J. Wagner Ralf J. Wagner Robert Hölzl
Technical Manager Test Engineer
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 6 from 23 © Kontron Elektronik GmbH All rights reserved
3. Data of Operation Mode and Configuration of EUT
3.1 Operation Mode
Special Susceptibility tests: Windows Screen Saver
Susceptibility tests: none
3.2 Configuration of Cables of EUT
3.3 Configuration of EUT
Display Samsung 21,3'' UXGA LTM213U3-L07
Backlight-Inverter Samsung SK2400H für LTM213U3-L07
Power supply Bicker SNP-Z107
Receiver Distec Prisma I (UXGA)
Power filter Schaffner FN321-1/05
Operating-System 1 MS WIN 98
3.4 Configuration of Peripherals of EUT
Channel Multiplexer 8 Channel
Keyboard: Cherry
Mouse: none
Configuration optional none
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 7 from 23 © Kontron Elektronik GmbH All rights reserved
4. Performed Tests and Results
Test Classification/Result Note
IEC 60068 PT2 -1 The requirements are fulfilled No degradation or loss of function or performance.
IEC 60068 PT2 -2 The requirements are fulfilled No degradation or loss of function or performance.
IEC 60068 PT2 -14 The requirements are fulfilled No degradation or loss of function or performance.
IEC 60068 PT2 -30 The requirements are fulfilled No degradation or loss of function or performance.
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 8 from 23 © Kontron Elektronik GmbH All rights reserved
5. Annotations to Performed Tests and to CE certification
5.1 The Test in the Climatic Chamber
Climatic chamber
Damp, Heat, Cold CyclicChamber Control
Computer Agilent 20 Channel
Multiplexer
(Test value recording)
Powersupply
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 9 from 23 © Kontron Elektronik GmbH All rights reserved
5.2 Basic environmental testing procedures
Test Db and guidance - damp heat, cyclic 12+12 HOUR
CYCLE (IEC 60068 PT2-30)
The object of the test is to determine the suitability of components, equipment or other articles for use and/or storage under conditions of high humidity when combined with cyclic temperature changes. This test replaces the original Test D in the Publication 68-2-4 for future applications (the parameters takes from the page 14)
Picture 1: Stabilizing period Picture 2: Test Db – test cycle
Picture 3: Recovery at controlled conditions
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 10 from 23 © Kontron Elektronik GmbH All rights reserved
6. Referenced Regulations
(see section "Reference Standards" for identical national standards) Regulation Comment
IEC 60068 PT2 -1 :1994
ENVIRONMENTAL TESTING - TESTS A: COLD
Concerns cold tests on both non-heat-dissipating and heat-dissipating specimens.
IEC 60068 PT2 -2
:1994
EN 60068 PT2-2 :1993
ENVIRONMENTAL TESTING - TESTS B: DRY HEAT
Contains Test Ba: Dry heat for non-heat-dissipating specimen with sudden change of temperature; Test Bb: Dry heat for non-heat-dissipating specimen with gradual change of temperature; Test Bc: Dry heat for heat-dissipating specimen with sudden change of temperature; Test Bd: Dry heat for heat-dissipating specimen with gradual change of temperature. The 1987 reprint includes IEC No. 62-2-2A.
IEC 60068 PT2 -14
:1984
EN 60068-2-14 :1999
ENVIRONMENTAL TESTING - PART 2-14 - TESTS - TEST N - CHANGE OF TEMPERATURE
Determines the ability of components, equipment and other articles to withstand rapid changes of ambient temperature. The exposure times to accomplish this depend upon the nature of the specimen.
IEC 60068 PT2 -30
:1980
EN 60068-2-30 :1999
BASIC ENVIRONMENTAL TESTING PROCEDURES - TEST DB AND GUIDANCE - DAMP HEAT, CYCLIC (12+12 HOUR CYCLE)
Determines the suitability of components, equipment and other articles for use and/or storage under conditions of high humidity when combined with cyclic temperature changes.
Special standard
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 11 from 23 © Kontron Elektronik GmbH All rights reserved
7. List of Test Equipment
Equipment Type Model Equipment No. Calibration valid until
Manufacturer
P Climatic Chamber VUK 04-500 PM-EM-6160-1 08.99 Heraus-Vötsch
P Control computer IPLite Color PM-EM-9599.01 not requested Kontron Elektronik
P Measuring system 34970A PM-EM-9519.01 not requested HP/Agilent
P Control computer Rx7000 PM-EM-9597.01 not requested Kontron Elektronik
P (check mark in 1st column) = tested with
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 12 from 23 © Kontron Elektronik GmbH All rights reserved
8. Photographs of EUT and Test Setup
Picture 4 : IEC Climatic Chamber
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 13 from 23 © Kontron Elektronik GmbH All rights reserved
9. Climatic conditions to IEC 60068
Time (Min.)
Humidity % Temperatur ° C
20 M i n .
60 Min . 180 Min .
200 Min.
rel. 20%
rel. 50%
21°C
55°C
Picture 5: IEC 60068 PT2-2 Test Bb:
Dry heat for non-heat-dissipating specimen with gradual change of temperature
0%
55%
Temperatur °C rel.Humidity %
TA=0°C
TB=60°C
21°C
Time (Min.) 0 20 90 210 270 390 510 630 690 Picture 6: IEC 60068 PT2-14 Test Nb:
Change of temperature with specified rate of change
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 14 from 23 © Kontron Elektronik GmbH All rights reserved
0%
55%
Temperatur °C rel.Humidity %
TA=0°C
21°C
Time (Min.) 0 30 90 210 270
Picture 7: IEC 60068 PT2-1 Test Ab:
Cold for non heat-dissipating specimen with gradual change of temperature
Temperatur °C rel.Humidity %
TA= 25°C
Ta 55°C
Time (h)
95%
60%
90%
24h
3 9 3 9 0
Picture 8: IEC 60068 PT2-30,Test Db:
12+12 Hour Cycle
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 15 from 23 © Kontron Elektronik GmbH All rights reserved
10. Temperature measurement
Inquiry of the temperature limits at temperature critical components.
Chosen critical components:
• Display Backside
• Controllerchip
• Power supply
• Backlight inverter
• System
• Ambient
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 16 from 23 © Kontron Elektronik GmbH All rights reserved
10.1 Layout : Temperature sensors KFM21_e
Controllerchip
Powersupply
DisplayBackside
Controllerchip
Power SupplyUnit
System
BacklightinverterDisplayBackside
Ambient
Picture 9: Mounting positions of the temperature sensors
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 17 from 23 © Kontron Elektronik GmbH All rights reserved
11. Temperature diagrams
into dependence of the surroundings to IEC 60068
(temperature, atmospheric humidity)
11.1 IEC 60068 PT2-2 Non Operating
have been done, but without recording
11.2 IEC 60068 PT2-1 Non Operating and
have been done, but without recording
11.3 IEC 60068 PT2-30 Non Operating
have been done, but without recording
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 18 from 23 © Kontron Elektronik GmbH All rights reserved
11.4 IEC 68-2-1 Operating
-10,00
0,00
10,00
20,00
30,00
40,00
50,00
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280
Time (Min)
°C
PSU Backlight Display Controllerchip System Ambient
Picture 10: Diagram of IEC 68-2-1 operating measurement
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 19 from 23 © Kontron Elektronik GmbH All rights reserved
11.5 IEC 68-2-2 Operating
0,00
10,00
20,00
30,00
40,00
50,00
60,00
70,00
80,00
90,00
0 10 20 30 40 5 0 60 70 8 0 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270
Time (Min)
°C
PSU Backlight Display Controllerchip System Ambient
Picture 11: Diagram of IEC 68-2-2 operating measurement
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 20 from 23 © Kontron Elektronik GmbH All rights reserved
11.6 IEC 68-2-14 Operating
- 5 , 0 0
5 , 0 0
1 5 , 0 0
2 5 , 0 0
3 5 , 0 0
4 5 , 0 0
5 5 , 0 0
6 5 , 0 0
7 5 , 0 0
0 24 48 72 96 120
144
168
192
216
240
264
288
312
336
360
384
408
432
456
480
504
528
552
576
600
624
648
672
696
720
744
768
792
816
840
864
888
912
T i m e ( M i n )
°C
P S U B a c k l i g h t D isp lay Cont ro l le rch ip S y s t e m A m b i e n t
Picture 12: Diagram of IEC 68-2-14 operating measurement
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 21 from 23 © Kontron Elektronik GmbH All rights reserved
11.7 IEC 68-2-14 Non Operating
- 2 5 , 0 0
- 1 5 , 0 0
-5 ,00
5 , 0 0
1 5 , 0 0
2 5 , 0 0
3 5 , 0 0
4 5 , 0 0
5 5 , 0 0
6 5 , 0 0
0 40 80 120 160 200 240 280 320 360 400 440 480 520 560 600 640 680 720 760 800 840 880 920 960 1000
1040
1080
1120
1160
1200
1240
1280
1320
1360
1400
1440
T i m e ( M i n )
° C
P S U B a c k l i g h t D i s p l a y B a c k s i d e Con t ro l l e r ch ip S y s t e m A m b i e n t
Picture 13: Diagram of IEC 68-2-14 non operating measurement
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 22 from 23 © Kontron Elektronik GmbH All rights reserved
12. Reference Standards
Tested standard Reference Standard (identical/similar to)
IEC 60068 PT2 -1 Identical with: BS EN 60068 PT2-1 DIN EN 60068 PT2 -1 DIN IEC 68 PT2-1 EN 60068 PT2-1 HD 323.2.1 JIS-C0020 NEN 10068-2-1 NFC 20-701 NF EN 60068-2-1 SEN 43 16 01 SS EN 60068
IEC 60068 PT2 -2 Technical Equivalent to: AS 1099:PT2BA AS 1099:PT2BB AS 1099:PT2BC AS 1099:PT2BD JIS-C8938
Identical with: BS EN 60068 PT2-2 DIN EN 60068 PT2 -2 DIN IEC 68 PT2-2 EN 60068 PT2-2 HD 323.2.2 JIS-C0021 JIS C0039 NEN 10068-2-2 NFC 20-702 NF EN 60068-2-2 SEN 43 16 02 SS EN 60068
IEC 60068 PT2 -14 Technical Equivalent to: AS 1099:PT2N AS 1099:PT2NA AS 1099:PT2NB AS 1099:PT2NC DIN EN 60068-2-14 JIS-C0025
Identical with: BS 2011:PT2.1N(1985) BS EN 60068-2-14 DIN IEC 60068-2-14 DIN IEC 68 PT2-14 EN 60068-2-14 HD 323.2.14 NEN 10068-2-14 NEN EN IEC 60068-2-14 NFC 20-714 NF EN 60068-2-14 SEN 43 16 13 SS EN 60068
KFM21_e Test Report No. 200011.001internal
E00680.00 Status: 30.05.2003 Page 23 from 23 © Kontron Elektronik GmbH All rights reserved
Tested standard Reference Standard (identical/similar to)
IEC 60068 PT2 -30 Technical Equivalent to: AS 1099:PT2D JIS-C0027
Identical with: BS 2011:PT2.1DB(1981) BS EN 60068-2-30 DIN EN 60068-2-30 DIN IEC 60068-2-30 DIN IEC 68 PT2-30 EN 60068-2-30 HD 323.2.30 NEN 10068-2-30 NEN EN IEC 60068-2-30 NFC 20-730 SS EN 60068