climate rental solutions - portable evaporative coolers
DESCRIPTION
Climate Rental Solutions portable evaporative coolers are ideal for large open spaces, whether it be a warehouse, school gymnasium or even marquee cooling, these units are sure to keep you cool.www.clmaterentals.com.au1300 447 247TRANSCRIPT
EXCL
USI
VE
TOEX
CLU
SIV
E TO
EXCL
USI
VE
TOEX
CLU
SIV
E TO
Delivery / Installation - 1 Unit $80 - Additional Units $30Removal / Return - 1 Unit $80 - Additional Units $30Unit Cost: $250 per Week / $110 per Day
ModelCooling CapacityCold Air Duct Diameter (mm)Hot Air Duct Diameter (mm)ThermostatAirflow (m3/hr)Dimensions (mm) H x W x DPower Supply (Voltage) / Current Consumption (Amperage)
MCM 2306.7kW
150150No
11701080 x 530 x 690
230v / 9 amps
ModelCooling CapacityCold Air Duct Diameter (mm)Hot Air Duct Diameter (mm)ThermostatAirflow (m3/hr)Dimensions (mm) H x W x DPower Supply (Voltage) / Current Consumption (Amperage)
MCM 2808.2kW
150200Yes
15001110 x 530 x 690230v / 9.8 amps
MCM 35010.2kW
200200Yes
20001170 x 815 x 665
230v / 11 amps
ModelCooling CapacityCold Air Duct Diameter (mm)Hot Air Duct Diameter (mm)ThermostatAirflow (m3/hr)Dimensions (mm) H x W x DPower Supply (Voltage) / Current Consumption (Amperage)
WPC 1684.9kW
120300Yes715
1042 x 523 x 672230v / 8.2 amps
ModelCooling CapacityCold Air Duct Diameter (mm)Hot Air Duct Diameter (mm)ThermostatAirflow (m3/hr)Dimensions (mm) H x W x DPower Supply (Voltage) / Current Consumption (Amperage)
WPC 2086.1kW
120300Yes790
1288 x 562 x 620230v / 9.5 amps
ModelCooling CapacityCold Air Duct Diameter (mm)Hot Air Duct Diameter (mm)ThermostatAirflow (m3/hr)Dimensions (mm) H x W x DPower Supply (Voltage) / Current Consumption (Amperage)
MCWC 2507.3kW
Yes1450
1350 x 820 x 380490 x 555 x 300230v / 11 amps
ModelCooling CapacityThermostatAirflow (m3/hr)Indoor Unit Dimensions (mm) H x W x DOutdoor Unit Dimensions (mm) H x W x DPower Supply (Voltage) / Current Consumption (Amperage)
Delivery / Installation - 1 unit $60 - Additional units $25 Removal / Return - 1 unit $60 - Additional units $25Unit Cost: $200 per week / $90 per day
Delivery / Installation - 1 Unit $60 - Additional Units $25Removal / Return - 1 Unit $60 - Additional Units $25Unit Cost: $250 per Week / $110 per Day
Delivery / Installation - 1 Unit $60 - Additional Units $25Removal / Return - 1 Unit $60 - Additional Units $25Unit Cost: $350 per Week / $150 per Day
Delivery / Installation - 1 Unit $60 - Additional Units $25Removal / Return - 1 Unit $60 - Additional Units $25Unit Cost: $150 per Week / $65 per Day
Delivery / Installation - 1 Unit $60 - Additional Units $25Removal / Return - 1 Unit $60 - Additional Units $25Unit Cost: $180 per Week / $80 per Day
6.7kWCOOLING
$90PER
DAY
8.2kWCOOLING
10.2kWCOOLING
7.3kWCOOLING
4.9kWCOOLING
6.1kWCOOLING
* All Prices Quoted Exclude Damage Waiver & GST
$200PER
WEEK
$110PER
DAY
$250PER
WEEK
$150PER
DAY
$350PER
WEEK
$110PER
DAY
$250PER
WEEK
$65PER
DAY
$150PER
WEEK
$80PER
DAY
$180PER
WEEK
EX
CL
US
IV
E T
OE
XC
LU
SIV
E T
OE
XC
LU
SIV
E T
OE
XC
LU
SIV
E T
O
ModelCooling CapacityCold Air Duct Diameter (mm)Hot Air Duct Diameter (mm)Sound RatingThermostatAirflow (m3/hr)Dimensions (mm) H x W x DWeightPower Supply (Voltage)Current Consumption (Amperage)
MCM 2306.7kW
150150
66dbNo
11701080 x 530 x 690
86kg230
9
ModelCooling CapacityCold Air Duct Diameter (mm)Hot Air Duct Diameter (mm)Sound RatingThermostatAirflow (m3/hr)Dimensions (mm) H x W x DWeightPower Supply (Voltage)Current Consumption (Amperage)
MCM 2808.2kW
150200
69dbYes
15001110 x 530 x 690
97kg2309.8
MCM 35010.2kW
200200
69dbYes
20001170 x 815 x 665
130kg230
11
ModelCooling CapacityCold Air Duct Diameter (mm)Hot Air Duct Diameter (mm)Sound RatingThermostatAirflow (m3/hr)Dimensions (mm) H x W x DWeightPower Supply (Voltage)Current Consumption (Amperage)
WPC 1684.9kW
120300
59dbYes715
1042 x 523 x 67286
2308.2
ModelCooling CapacityCold Air Duct Diameter (mm)Hot Air Duct Diameter (mm)Sound RatingThermostatAirflow (m3/hr)Dimensions (mm) H x W x DWeightPower Supply (Voltage)Current Consumption (Amperage)
WPC 2086.1kW
120300
62dbYes790
1288 x 562 x 62090
2309.5
ModelCooling CapacityCold Air Duct Diameter (mm)Hot Air Duct Diameter (mm)Sound RatingThermostatAirflow (m3/hr)Dimensions (mm) H x W x DWeightPower Supply (Voltage)Current Consumption (Amperage)
MCWC 2507.3kW60db
Yes1450
1350 x 820 x 380490 x 555 x 300
125kg230
11
ModelCooling CapacitySound RatingThermostatAirflow (m3/hr)Indoor Unit Dimensions (mm) H x W x DOutdoor Unit Dimensions (mm) H x W x DWeightPower Supply (Voltage)Current Consumption (Amperage)
6.7kWCOOLING
8.2kWCOOLING
10.2kWCOOLING
7.3kWCOOLING
4.9kWCOOLING
6.1kWCOOLING
EXCL
USI
VE
TOEX
CLU
SIV
E TO
EXCL
USI
VE
TOEX
CLU
SIV
E TO
EXCL
USI
VE
TO
ModelNominal Heat Output (kW)Airflow (m3/hr)Dimensions (mm) H x W x DWeightPower Supply (Voltage)Nominal Current Consuption (Amps)
ModelNominal Heat Output (kW)Airflow (m3/hr)Dimensions (mm) H x W x DWeightPower Supply (Voltage)Nominal Current Consuption (Amps)
FF 1212.7
1200360 x 300 x 330
15415
12
FF 2020
1850460 x 290 x 483
20415
22
ModelNominal Heat Output (kW)Airflow (m3/hr)Dimensions (mm) H x W x DWeightPower Supply (Voltage)Nominal Current Consuption (Amps)
ModelNominal Heat Output (kW)Airflow (m3/hr)Dimensions (mm) H x W x DWeightPower Supply (Voltage)Nominal Current Consuption (Amps)
FF 1313.9
1017380 x 300 x 450
18415
12
FF 2928.9
2034570 x 400 x 520
36415
22
ModelNominal Heat Output (kW)Airflow (m3/hr)Dimensions (mm) H x W x DWeightPower Supply (Voltage)Nominal Current Consuption (Amps)
FF 4243
40001000 x 700 x 1100
130415
61
ModelAirflow (m3/hr)Power Supply (Voltage)Current Consumption (Amps)Fan SpeedWater Tank Capacity (Litres)WeightDimensions (mm) H x W x D
ModelAirflow (m3/hr)Power Supply (Voltage)Current Consumption (Amps)Fan SpeedWater Tank Capacity (Litres)WeightDimensions (mm) H x W x D
MEC 120 - 12 000
230v2 amps
Variable115L78kg
1560 x 1270 x 680
MEC 200 - 20 400
230v2.5ampsVariable
200L105kg
1800 x 1600 x 780
The MEC 12, Mobile Evaporative Cooler, provides up to 12000m3/hr of cooling. It comes with a fully adjustable fan, strong lockable castor wheels and can be run with or without the cooling mode activated. The MEC 12 has a very large water reservoir, so if you do not have access to a continuous water feed, you will able to get hours of operation before the unit requires topping up. The MEC 12 is ideal for large open spaces such as factories, warehouses, gyms and workshops. This unit operates from a standard 10 amp power supply.
The MEC 20, Mobile Evaporative Cooler, is the big brother of the MEC 12. It provides a massive 20,000m3/hr of cooling. The MEC 20 has all the features of the MEC 12, with the addition of a intelligent control system. This allows you to set the required air temperature and even the time period you wish the unit to operate. It is ideal for large open spaces such as factories, warehouses, gyms and workshops. The MEC 20 operates from a standard 10 amp power supply.
0 - 12000
3 amps
0 - 20400
3.5amps