citysaver - led street & road light · • energy efficient family of led luminaires for...

7
All information is believed to be accurate at the time of publication. Please contact customer service or visit www.xtralight.com for the most updated product specifications. XtraLight reserves the right to change specifications without notice. PROJECT INFORMATION Project Name Catalog # Date Type www.xtralight.com (800) 678-6960 [email protected] CSR-S.M-036.150 190909 FEATURES • Energy efficient family of LED luminaires for replacement of up to 400W HID. • Familiar cobra head style, optimized for LED operation and performance. • Tool-free access to mounting and electrical components. • Controls ready luminaire is standard for independent operation or remote management. • Multiple light distributions and lumen levels for diverse application requirements covering all roadway needs. • Ease of installation, long service life and minimal maintenance. • Operating temperature: -40°C to +50°C (-40°F to +122°F) CONSTRUCTION • Housing and door are one-piece die-cast aluminum with integral mounting for strength and durability. • Door is removable without tools and rear-hinged for ease of installation and service. LED boards and drivers are mounted directly to the housing’s integral heat sink for thermal management and maximum service life. • No lens frame or secondary glass for maximum performance. • All fasteners are stainless steel. • Housing and door are protected with a thermoset TGIC-polyester powder coat finish using a tightly controlled multi-stage process to a uniform 3 mil thickness (min). This finish provides superior protection from corrosion and maximum environmental durability. MOUNTING • Integral horizontal mast arm mounting for 1-1/4” to 2”IP (1.66”- 2.38”OD) for compatibility and ease of installation. • Horizontal orientation with internal +/− 5° adjustment for leveling in 2.5° increments. • Bubble Level for lateral and longitudinal orientation provides quick visual reference, speeding installation. • Bird guard for arm diameters smaller than 2”IP (2.38” OD). OPTICS • Precision molded optics for superior uniformity, minimal light trespass and maximum pole spacing. • Optical grade polymer is UV stabilized and impact resistant. • IP66 rated LED light engines prevent dust and moisture from degrading performance. • Distributions: Type II, Type III, Type IV and Type V. • Best in class LEDs with 3000K, 4000K, 5000K and 5700K CCT (min 70 CRI). • Zero uplight (U0) is night sky friendly, reduces wasted light. • Lumen Maintenance: >100,000hrs L 70 @ 25°C. • Optional backlight shielding available for Type II, Type III and Type IV distributions protects against light trespass. ELECTRICAL • All serviceable components are assembled and pre-wired using quick connects. • Voltage: 120-277V 50/60Hz universal driver or optional 347/480V. • Surge Protection: 20kA standard. • Dimming: 0-10v dimmable driver is standard. • Controls: 5-pin twist-lock receptacle is standard (optional 7-pin) for controls ready operation. • Photocontrol or shorting cap required for operation, but not included. • Terminal block adjacent to arm mounting for ease of installation. • ANSI wattage labels provided as standard. • Passive Infrared (PIR) Photo/Motion Sensor available as an option. WARRANTY • 10-year Limited Warranty. APPROVALS ETL listed: Complies with UL 1598 and CSA C22.2 No. 250.0-08; Suitable for wet locations. 3G Vibration Rated for Bridge/Overpass Applications per ANSI C136.31-2010, Test Level 2. Select models DLC Qualified. For a complete list of DLC Qualified products, please visit: http://www.xtralight.com/dlc or www.designlights.org/qpl APPLICATIONS Replacement of existing HID cobra head luminaires and new installations Residential & Local Streets Local & Major Roadways • Intersections & Cross-walks Alleys and Pedestrian Walkways CITYSAVER™ ROADWAY LED LUMINAIRE COMPLIANCE ANSI C136.2, .3, .10, .14, .15, .22, .25, .31, .37 and .41 ANSI/IES RP-8-14 Roadway Lighting MSSLC Model Specification for LED Roadway Luminaires v2 (2014) PRODUCT PERFORMANCE MODEL REPLACES LUMENS EFFICACY CSR-S 36 & 52 UP TO 150W HID UP TO 7200 UP TO 141 CSR-M 75, 96, 125 & 150 UP TO 400W HID UP TO 20500 UP TO 131 T E N Y E A R W A R R A N T Y

Upload: others

Post on 27-Apr-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CitySaver - LED Street & Road Light · • Energy efficient family of LED luminaires for replacement of up to 400W HID. • Familiar cobra head style, optimized for LED operation

All information is believed to be accurate at the time of publication. Please contact customer service or visit www.xtralight.com for the most updated product specifications. XtraLight™ reserves the right to change specifications without notice.

PROJECT INFORMATION

Project Name

Catalog #

Date

Type

www.xtralight.com • (800) 678-6960 • [email protected] 190909

FEATURES • Energy efficient family of LED luminaires for replacement of up

to 400W HID.

• Familiar cobra head style, optimized for LED operation and performance.

• Tool-free access to mounting and electrical components.

• Controls ready luminaire is standard for independent operation or remote management.

• Multiple light distributions and lumen levels for diverse application requirements covering all roadway needs.

• Ease of installation, long service life and minimal maintenance.

• Operating temperature: -40°C to +50°C (-40°F to +122°F)

CONSTRUCTION• Housing and door are one-piece die-cast aluminum with integral

mounting for strength and durability.

• Door is removable without tools and rear-hinged for ease of installation and service.

• LED boards and drivers are mounted directly to the housing’s integral heat sink for thermal management and maximum service life.

• No lens frame or secondary glass for maximum performance.

• All fasteners are stainless steel.

• Housing and door are protected with a thermoset TGIC-polyester powder coat finish using a tightly controlled multi-stage process to a uniform 3 mil thickness (min). This finish provides superior protection from corrosion and maximum environmental durability.

MOUNTING• Integral horizontal mast arm mounting for 1-1/4” to 2”IP (1.66”-

2.38”OD) for compatibility and ease of installation.

• Horizontal orientation with internal +/− 5° adjustment for leveling in 2.5° increments.

• Bubble Level for lateral and longitudinal orientation provides quick visual reference, speeding installation.

• Bird guard for arm diameters smaller than 2”IP (2.38” OD).

OPTICS• Precision molded optics for superior uniformity, minimal light

trespass and maximum pole spacing.

• Optical grade polymer is UV stabilized and impact resistant.

• IP66 rated LED light engines prevent dust and moisture from degrading performance.

• Distributions: Type II, Type III, Type IV and Type V.

• Best in class LEDs with 3000K, 4000K, 5000K and 5700K CCT (min 70 CRI).

• Zero uplight (U0) is night sky friendly, reduces wasted light.

• Lumen Maintenance: >100,000hrs L70

@ 25°C.

• Optional backlight shielding available for Type II, Type III and Type IV distributions protects against light trespass.

ELECTRICAL• All serviceable components are assembled and pre-wired using

quick connects.

• Voltage: 120-277V 50/60Hz universal driver or optional 347/480V.

• Surge Protection: 20kA standard.

• Dimming: 0-10v dimmable driver is standard.

• Controls: 5-pin twist-lock receptacle is standard (optional 7-pin) for controls ready operation.

• Photocontrol or shorting cap required for operation, but not included.

• Terminal block adjacent to arm mounting for ease of installation.

• ANSI wattage labels provided as standard.• Passive Infrared (PIR) Photo/Motion Sensor available as an

option.

WARRANTY• 10-year Limited Warranty.

APPROVALS• ETL listed: Complies with UL 1598 and CSA C22.2 No. 250.0-08; Suitable for wet locations.• 3G Vibration Rated for Bridge/Overpass Applications per ANSI C136.31-2010, Test Level 2.• Select models DLC Qualified. For a complete list of DLC Qualified products, please

visit: http://www.xtralight.com/dlc or www.designlights.org/qpl

APPLICATIONS• Replacement of existing HID cobra

head luminaires and new installations• Residential & Local Streets

• Local & Major Roadways• Intersections & Cross-walks• Alleys and Pedestrian Walkways

CITYSAVER™ROADWAY LED LUMINAIRE

COMPLIANCE• ANSI C136.2, .3, .10, .14, .15, .22, .25, .31, .37 and .41• ANSI/IES RP-8-14 Roadway Lighting• MSSLC Model Specification for LED Roadway Luminaires v2 (2014)

PRODUCT PERFORMANCEMODEL REPLACES LUMENS EFFICACY

CSR-S 36 & 52UP TO

150W HIDUP TO

7200UP TO

141

CSR-M 75, 96, 125 & 150UP TO

400W HIDUP TO 20500

UP TO

131TEN YEAR

WARRANTY

Page 2: CitySaver - LED Street & Road Light · • Energy efficient family of LED luminaires for replacement of up to 400W HID. • Familiar cobra head style, optimized for LED operation

ORDER LOGIC

CSR-S.M-036.150 190909 All information is believed to be accurate at the time of publication. Please contact customer service or visit www.xtralight.com for the

most updated product specifications. XtraLight™ reserves the right to change specifications without notice.

www.xtralight.com • (800) 678-6960 • [email protected]

MODULE OPTICS DRIVER SURGE MOUNT OPTIONS

01 2M Type II Medium DIM Dimmable Multi-Volt 120-277V (Std)

20 20kV/20kA (Std) 2 2 2 Bolt/Single Brkt

HS House Side

02 3M Type III Medium Shield

03 4S Type IV Short HVD 5 Dimmable 347V or 480V 4 3 4 Bolt/Dual Brkt5M Type V Square Medium

CITYSAVER™ROADWAY LED LUMINAIRE

1. Photocontrol not included.2. Single bracket/2-Bolt mount is standard on CSR-S, N/A on CSR-M.3. Dual bracket/4-Bolt mount is optional on CSR-S, standard on CSR-M.4. FSP-211 sensors are not to be used with twist-lock receptacles.5. 347V driver option only available for CSR-M 075 and CSR-M 096 models.

CitySaver Small CitySaver Medium

SIDE

BOTTOM

TOP

REARFRONT

CITYSAVER SMALL FIXTURE

1CitySaver SMSHEET 1 OF 1

4/11/16RBS

NOT TO SCALE

REVDWG. NO.

ASIZE

TITLE:NAME DATE

Q.A.

MFG APPR.

ENG APPR.

CHECKED

DRAWN

FINISH

MATERIAL

DIMENSIONS ARE IN INCHESTOLERANCES:ANGULAR: MACH BEND 1THREE PLACE DECIMAL 0.020

PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFXTRA LIGHT MFG. ANY REPRODUCTIONIN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OFXTRA LIGHT MFG. IS PROHIBITED.

SIDEFRONT REAR

BOTTOM

TOP

CITYSAVER MEDIUM FIXTURE

1CitySaver MedSHEET 1 OF 1

4/11/16RSS

NOT TO SCALE

REVDWG. NO.

ASIZE

TITLE:NAME DATE

Q.A.

MFG APPR.

ENG APPR.

CHECKED

DRAWN

FINISH

MATERIAL

DIMENSIONS ARE IN INCHESTOLERANCES:ANGULAR: MACH BEND 1THREE PLACE DECIMAL 0.020

PROPRIETARY AND CONFIDENTIAL

THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFXTRA LIGHT MFG. ANY REPRODUCTIONIN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OFXTRA LIGHT MFG. IS PROHIBITED.

• EPA: 0.72 sq ft

• 14 lbs.

• 25.8” L x 9.5” W x 5.1” H

• EPA: 1.14 sq ft

• 22 lbs.

• 29.5” L x 13.0” W x 5.2” H

ISO LinesDistance in Units of Mounting Height Values Based on 25 Foot Mounting Height.

Type II Medium

Type III Medium

Type IV Short

Type V Square Medium

N GY

SIZE MODEL ORIENTATION CCT

S Small 036 N Normal (Forward) 30K 3000KM Medium 052 40K 4000K

075 50K 5000K096 57K 5700K

125

150

CSR

Size & Model Combinations:CSR-S-01-036

CSR-S-01-052CSR-M-02-075CSR-M-02-096CSR-M-03-125CSR-M-03-150

Sample part no.: CSR-M-02-075-3M-N-DIM-40K-20-5-4-GY

DIMENSIONAL DATA

PHOTOMETRIC DATA

CONTROLS

5 1 Twist-Lock Receptacle, 5-pin (Std)

7 1 Twist-Lock Receptacle, 7-pinB 4 FSP-211L3@20’MH/40’DIAD 4 FSP-211L7@40’MH/100’DIA

COLOR

GY Grey

Page 3: CitySaver - LED Street & Road Light · • Energy efficient family of LED luminaires for replacement of up to 400W HID. • Familiar cobra head style, optimized for LED operation

CSR-S.M-036.150 190909 All information is believed to be accurate at the time of publication. Please contact customer service or visit www.xtralight.com for the

most updated product specifications. XtraLight™ reserves the right to change specifications without notice.

www.xtralight.com • (800) 678-6960 • [email protected]

PHOTOMETRIC DATA

CITYSAVER™ROADWAY LED LUMINAIRE

Lumen Charts4000K CCT Additional CCT Information

Lumen Multiplier

vs CCT CSR-S

CCT Multiplier

3000K 0.84

4000K 1.00

5000K 0.96

5700K 0.97

ModelType II Medium

IES Report

LumensSystem Watts

Efficacy (Lm/W)

BUG Rating

36 SCALED 4729 36 131 B1-U0-G1

52 SCALED 6861 56 123 B1-U0-G1

75 SCALED 9691 73 133 B2-U0-G2

96 SCALED 12814 106 121 B2-U0-G2

125 SCALED 15369 121 127 B2-U0-G3

150 SCALED 19430 156 125 B3-U0-G3

Lumen Maintenance vs Ambient Temperature CSR-S

Ambient (°C)

TM-21 Lumen Maintenance (60,000 hrs)

Theoretical L70 Hours

Calculated Lumen Maintenance

25K hr. 50K hr. 75K hr. 100K hr

25 92.46 226,000 98.06 94.03 90.17 86.46

30 91.88 212,000 97.8 93.53 89.45 85.55

35 90.94 194,000 97.38 92.73 88.31 84.09

40 89.95 177,000 96.94 91.89 87.11 82.57

45 88.91 163,000 96.47 91.01 85.85 80.99

* Lumen maintenance calculations based on test report ATAL013875.

ModelType III Medium

IES Report

LumensSystem Watts

Efficacy (Lm/W)

BUG Rating

36 SCALED 4721 36 131 B1-U0-G1

52 SCALED 6782 56 121 B1-U0-G1

75 SCALED 9580 73 131 B2-U0-G2

96 SCALED 12668 106 120 B2-U0-G2

125 SCALED 15541 121 128 B2-U0-G2

150 SCALED 19289 156 124 B2-U0-G3

ModelType IV Short

IES Report

LumensSystem Watts

Efficacy (Lm/W)

BUG Rating

36 SCALED 4765 36 132 B1-U0-G1

52 SCALED 6993 56 125 B1-U0-G2

75 SCALED 9878 73 135 B2-U0-G2

96 SCALED 13061 106 123 B2-U0-G3

125 SCALED 15541 121 128 B2-U0-G3

150 SCALED 19647 156 126 B3-U0-G3

ModelType V Medium

IES Report

LumensSystem Watts

Efficacy (Lm/W)

BUG Rating

36 SCALED 5064 36 141 B3-U0-G2

52 SCALED 7164 56 128 B3-U0-G2

75 SCALED 10119 73 139 B3-U0-G3

96 SCALED 13380 106 126 B4-U0-G3

125 SCALED 16174 121 134 B4-U0-G3

150 SCALED 20447 156 131 B4-U0-G3

Lumen Maintenance vs Ambient Temperature CSR-M

Ambient (°C)

TM-21 Lumen Maintenance (60,000 hrs)

Theoretical L70 Hours

Calculated Lumen Maintenance

25K hr. 50K hr. 75K hr. 100K hr

25 91.30 201,000 97.54 93.04 88.75 84.65

30 90.33 183,000 97.11 92.22 87.57 83.16

35 89.31 168,000 96.65 91.35 86.34 81.60

40 88.25 154,000 96.17 90.44 85.05 80.00

* Lumen maintenance calculations based on test report. ATAL013936

Lumen Multiplier

vs CCT CSR-M

CCT Multiplier

3000K 0.84

4000K 1.00

5000K 0.93

5700K 0.98

Lumen Multiplier

vs Ambient

Ambient (°C)

Lumen

Multiplier

-30 1.040

0 1.025

25 1.000

30 0.990

35 0.986

40 0.978

45 0.968

Page 4: CitySaver - LED Street & Road Light · • Energy efficient family of LED luminaires for replacement of up to 400W HID. • Familiar cobra head style, optimized for LED operation

CSR-S.M-036.150 190909 All information is believed to be accurate at the time of publication. Please contact customer service or visit www.xtralight.com for the

most updated product specifications. XtraLight™ reserves the right to change specifications without notice.

www.xtralight.com • (800) 678-6960 • [email protected]

LIGHTING CONTROLS

CITYSAVER™ROADWAY LED LUMINAIRE

OPTION B FSP-211L3 20' Mounting Height 40' Diameter

OPTION D FSP-211L7 40’ Mounting Height 100’ Diameter

www.wattstopper.com8 0 0 . 8 7 9 . 8 5 8 5

Coverage

Dimensions of Lens Options

FSP-L3 top and side coverage patterns

FSP-L4 top and side coverage patterns

FSP-L2 top and side coverage patterns

FSP-L2 dimensions FSP-L3 dimensions FSP-L4 dimensions

0’ 3’ 6’ 12’ 27’30’

3’6’12’27’30’

20’ 20’

0’3’6’

3’6’

12’

27’

30’

12’

27’

20’

20’

60’

30’

0’

10’

20’

30’

40’0’ 6’ 12’ 30’6’12’20’ 20’

20’ 10’ 0’ 10’ 20’

0’

20’

10’

10’

20’

40’

0’3’ 9’6’3’6’9’12’ 12’

10’

20’

0’

15’

5’

15’18’20’ 15’ 18’ 20

0'

8'

0' 3'3' 7'7' 11'11' 24'24'

30'

20'

10'

10'

20'

0'

10' 0' 10' 20'20'

60 ft

2.33”59.2mm

0.78”19.7mm

2.33”59.2mm

0.78”19.7mm

3.2”81.3mm

0.93”23.6mm

FSP-L7 top and side coverage patterns0'10' 10'20' 20'30' 30'40' 40'

0'

27'

40'

50'50'50' 25' 0' 25' 50'

0'

50'

25'

25'

50'

100'

FSP-L7 dimensions

3.2”81.3mm

1.04”26.4mm

www.wattstopper.com8 0 0 . 8 7 9 . 8 5 8 5

Coverage

Dimensions of Lens Options

FSP-L3 top and side coverage patterns

FSP-L4 top and side coverage patterns

FSP-L2 top and side coverage patterns

FSP-L2 dimensions FSP-L3 dimensions FSP-L4 dimensions

0’ 3’ 6’ 12’ 27’30’

3’6’12’27’30’

20’ 20’

0’3’6’

3’6’

12’

27’

30’

12’

27’

20’

20’

60’

30’

0’

10’

20’

30’

40’0’ 6’ 12’ 30’6’12’20’ 20’

20’ 10’ 0’ 10’ 20’

0’

20’

10’

10’

20’

40’

0’3’ 9’6’3’6’9’12’ 12’

10’

20’

0’

15’

5’

15’18’20’ 15’ 18’ 20

0'

8'

0' 3'3' 7'7' 11'11' 24'24'

30'

20'

10'

10'

20'

0'

10' 0' 10' 20'20'

60 ft

2.33”59.2mm

0.78”19.7mm

2.33”59.2mm

0.78”19.7mm

3.2”81.3mm

0.93”23.6mm

FSP-L7 top and side coverage patterns0'10' 10'20' 20'30' 30'40' 40'

0'

27'

40'

50'50'50' 25' 0' 25' 50'

0'

50'

25'

25'

50'

100'

FSP-L7 dimensions

3.2”81.3mm

1.04”26.4mm

WWW.LEGRAND.US/WATTSTOPPER

WATTSTOPPER®FIXTURE SENSORS & CONTROLS

DescriptionThe FSP-211 mounts in an outdoor lighting fixture and provides multi-level control based on motion and/or daylight contribution. It controls 0-10 VDC LED drivers or dimming ballasts, as well as non-dimming ballasts and, with an FSP-Lx Lens, is rated for wet and cold locations. All control parameters are adjustable via a wireless configuration tool capable of storing and transmitting sensor profiles.

OperationTypically, the sensor ramps lighting On to the selected High mode level when motion is detected and the ambient light level is below the hold off setpoint. After the sensor stops detecting movement and the time delay elapses, lights fade to the Low mode level. If there is no motion during the subsequent cut off time delay, the lights will turn Off. For dusk to dawn control, the integral photocell can switch the lights On and Off based on the ambient light level so that lighting remains on overnight even without motion detection.

Wireless Handheld Configuration ToolInitial setup and subsequent sensor adjustments are made using a handheld configuration tool (FSIR-100). This tool enables adjustment of parameters including high and low modes, sensitivity, time delay, cut off and more. The FSIR-100 is also used to initiate automatic calibration of the FSP-211 ambient light level setpoint. The setpoint is used to hold the controlled lighting off or at low level when there is sufficient daylight. The wireless tool stores up to six sensor parameter profiles to speed configuration of multiple sensors.

ApplicationsThe slim, low-profile FSP-211 is designed for installation inside the bottom of a light fixture body. When fully assembled and installed in an IP66-rated fixture, the sensor and FSP-Lx lenses are IP66 outdoor rated. The sensor is ideal for areas such as parking facilities, gas stations, pedestrian pathways and warehouses. A choice of four lenses ensures complete coverage for mounting heights up to 40’.

LINE VOLTAGE HIGH/LOW/OFF PIR FIXTURE INTEGRATED OUT-DOOR PHOTO/MOTION SENSOR

FSP-211

• Provides line voltage On/Off switching and 0-10 VDC dimming control

• Works with ballasts or LED drivers

• High and low modes fully adjustable from 0 to 10V

• Time delay from 5 to 30 minutes

• Optional cut off delay

• Adjustable ramp up and fade down times

• Optional daylighting setpoints feature automatic calibration, or permit manual adjustment

• Configuration tool stores six sensor profiles for quick setup and adjustment of multiple sensors

• Polycarbonate construction; flame retardant, UV resistant, impact resistant, recyclable

• UL244A and UL508; IP66 rated (when fully assembled and installed) for use in wet locations

• This product meets the materials restrictions of RoHS

• BAA/TAA-compliant models available

Features

Fully adjustable high and low dimmed light levels; optional

dusk to dawn control

Adjustable via handheld wireless configuration tool

Adjustable time delay and cut off delay

Designed for LED fixtures; rated for extreme

temperatures and up to 200,000 on/off cycles

IP66 rated with choice of lenses for wet and outdoor locations, and mounting heights from 8’ to 40’

Hold off setpoint with automatic calibration option

for convenience and added energy savings

WATTSTOPPER®

Page 5: CitySaver - LED Street & Road Light · • Energy efficient family of LED luminaires for replacement of up to 400W HID. • Familiar cobra head style, optimized for LED operation

CSR-S.M-036.150 190909 All information is believed to be accurate at the time of publication. Please contact customer service or visit www.xtralight.com for the

most updated product specifications. XtraLight™ reserves the right to change specifications without notice.

www.xtralight.com • (800) 678-6960 • [email protected]

HOUSE SIDE SHIELD OPTICS ACCESSORY

CITYSAVER™ROADWAY LED LUMINAIRE

FEATURES

• Significantly reduces backlight to minimize light trespass.

• Available for Type II Medium (2M), Type III Medium (3M) and Type IV Short (4S) optics.

• Factory installed as an option when ordered with the luminaire.

• Field installable (tool-free) when ordered as a separate accessory.

CONSTRUCTION

• Low-profile, precision fabricated CNC design.

• Flat black TGIC-polyester powder coat finish using tightly controlled multi-stage process to a uniform 3 mil thickness (min). This finish provides superior protection from corrosion and maximum environmental durability.

DIMENSIONS

• 11.38” L x 3.88” W x 0.4” H • 0.33 lbs

- HSS -

ACCESSORY

HSS House Side Shield

SIZE

1 Small36W/52W

2 Medium75W/96W

3 Medium125W/150W

CSR

ORDER LOGIC PHOTOMETRIC DATA

IES DISTRIBUTION TYPES

ISO Lines Distance in Units of Mounting Height Values Based on 25 Foot Mounting Height

.1

.2.5

1 2

Type II Medium + HSS

.1

.2

.51

2

Type III Medium + HSS

.1

.2

.5

1

2

Type IV Short + HSS

4000K CCT

ModelOptic Type

+ HSSBUG

RatingLumens

CSR-S-052

TYPE II M B0-U0-G1 4399

TYPE III M B1-U0-G1 4180

TYPE IV S B0-U0-G1 4216

CSR-M-096

TYPE II M B1-U0-G2 8007

TYPE III M B1-U0-G2 8312

TYPE IV S B1-U0-G2 7735

CSR-M-150

TYPE II M B1-U0-G3 11383

TYPE III M B1-U0-G2 11961

TYPE IV S B0-U0-G1 11227

Page 6: CitySaver - LED Street & Road Light · • Energy efficient family of LED luminaires for replacement of up to 400W HID. • Familiar cobra head style, optimized for LED operation

CSR-S.M-036.150 190909 All information is believed to be accurate at the time of publication. Please contact customer service or visit www.xtralight.com for the

most updated product specifications. XtraLight™ reserves the right to change specifications without notice.

www.xtralight.com • (800) 678-6960 • [email protected]

MOUNTING ACCESSORIES

CITYSAVER™ROADWAY LED LUMINAIRE

Square Direct Pole Mount

CSR-SDPM-GY• 2” diameter pipe

• A = 10”

• Minimum 4” square pole

• 9/16” diameter mounting holes

• 4” x 5 1⁄4” mounting plate

• Mounting hardware not included

A

3 3⁄16”

Page 7: CitySaver - LED Street & Road Light · • Energy efficient family of LED luminaires for replacement of up to 400W HID. • Familiar cobra head style, optimized for LED operation

CSR-S.M-036.150 190909 All information is believed to be accurate at the time of publication. Please contact customer service or visit www.xtralight.com for the

most updated product specifications. XtraLight™ reserves the right to change specifications without notice.

www.xtralight.com • (800) 678-6960 • [email protected]

DIMMING CONTROL ACCESSORY

CITYSAVER™ROADWAY LED LUMINAIRE

FEATURES

• Stand alone twistlock photocontrol dimming solution for XtraLight Viento and CitySaver luminaires.

• No network required and is field adjustable.

• Robust surge protection - 40K Amp MOV/640Joule.

• Factory installed as an option when ordered with the luminaire.

• Field installable (tool-free) when ordered as a separate accessory.

CONSTRUCTION

• Cover: Black or Blue Polypropylene.

• Base: Polycarbonate UL94HB Flame Class Rating.

• Gasket: Neoprene ASTM D 1056.

• Circuit Board: Moisture repellent glass epoxy.

DIMMING OPTIONS

• Constant dim level version available.

• Three different dim levels and times option setting selections on bottom base ten position trim pot.

• 30%, 50% and 70% dim levels.

• Dim start at 10 PM, Midnight or 2 AM.

• Priority algorithm adjusts for seasons and daylight saving time changes.

ORDER LOGIC

LOAD RATING 1,000W/1,800 VA15 AMP RELAY TESTED TO 15,000 OPERATIONS ON MAXIMUM AVAILABLE LED OR INDUCTION LOAD

OPERATING TEMPERATURE -40°C TO +70°C -40°F TO +158F°

SURGE PROTECTION 40,000 AMPS SINGLE 640 JOULE MOV

POWER CONSUMPTION <0.5 WATTS @ 120 V

DIELECTRIC STRENGTH 5,000 VOLTS BETWEEN CURRENT CARRYING PARTS

DIMMING PHOTOCONTROL ELECTRICAL INFORMATION

MS5559 - Scheduled Dimming, Standard Voltage 105-305 VAC, 50/60 Hz

MS5560 - Scheduled Dimming, High Voltage 312-530 VAC, 50/60 Hz

MS5561 - Constant All-Night Dimming, Standard Voltage 105-305 VAC, 50/60 Hz

MS5562 - Constant All-Night Dimming, High Voltage 312-530 VAC, 50/60 Hz

CITYSAVER™ ROADWAY LUMINAIRE WITH DIMMING CONTROL ACCESSORY

MODEL STEP% OF WATTAGE

OUTPUT% OF LUMEN

OUTPUT

CSRR

0 100% 100%

1 100% 100%

2 89% 93%

3 77% 84%

4 66% 74%

5 55% 64%

6 43% 52%

7 33% 40%

8 22% 26%

9 13% 14%