DESIGNED AND ENGINEERED BY: LOCUS MAP 1 BUILDING DESIGN CRITERIA: CIVIL ENGINEERING STRUCTURAL ENGINEERING ARCHITECTURAL MECHANICAL ENGINEERING PLUMBING ENGINEERING FIRE PROTECTION ENGINEERING ELECTRICAL ENGINEERING THE HL TURNER GROUP INC. THE HL TURNER GROUP INC. THE HL TURNER GROUP INC. TURNER BUILDING SCIENCE, LLC. TURNER BUILDING SCIENCE, LLC. TURNER BUILDING SCIENCE, LLC. BLW ENGINEERS, INC. T:603.228.1122 T:207.583.4571 T:978.486.4301 F:603.228.1124 F:207.583.4572 F:978.428.0067 PROJECT NUMBER: LOCUS MAP 2 CONSTRUCTED BY: CONCORD NH HARRISON ME LYNDONVILLE VT LITTLETON MA NEW HAVEN CT 27 LOCKE ROAD CONCORD, NEW HAMPSHIRE 03301 T:603.228.1122 / F:603.228.1126 W:www.hlturner.com ARCHITECTS ENGINEERS CONSTRUCTION MANAGERS BUILDING SCIENTISTS THE H.L. TURNER GROUP Inc. ARCHITECT OF RECORD: ARCHITECT NAME HL TURNER GROUP, INC. 8/25/2016 9:25:54 AM CITY WIDE COMMUNITY CENTER COVER COVER SHEET 14 Canterbury Rd Concord, NH 03301 08/25/2016 4401 SCHEMATIC DESIGN DRAWING LIST SHEET NUMBER DRAWING TITLE 00 GENERAL COVER COVER SHEET 01 CIVIL CX GENERAL NOTES AND LEGENDS C1.0 EXISTING CONDITIONS PLANS C1.1 SITE PREPARATION PLANS C2.0 SITE PLAN C3.0 GRADING PLAN C4.0 UTILITY PLAN C6.0 SITE DETAILS C7.0 UTILITY DETAILS 02 STRUCTURAL S1.1 FOUNDATION PLAN S2.2 ROOF FRAMING PLAN 03 ARCHITECTURAL A0.1 LEGEND & GENERAL INFORMATION A0.2 CODE ANALYSIS A1.1 EXISTING CONDITIONS FLOOR PLAN - AREA A (16,488 SQ. FT.) A1.2 EXISTING CONDITIONS FLOOR PLAN AREA B (5,372 SQ. FT.) A1.3 EXISTING CONDITIONS FLOOR PLAN AREA C (6,989 SQ. FT.) A1.4 PROPOSED FLOOR PLAN A1.5 ROOF PLAN A1.6 ENLARGED PLAN A1.7 ENLARGED PLAN A3.2 NEW CONSTRUCTION EXTERIOR ELEVATIONS A4.1 BUILDING SECTIONS & WALL SECTIONS 04 PLUMBING P0.0 COVER SHEET P1.1 FIRST FLOOR OVERALL PLAN 06 ELECTRICAL E0.1 LEGEND E0.2 SCHEDULES AND POWER RISER DIAGRAM E0.3 FIRE ALARM RISER E0.4 SITE PLAN DEMOLITION AND NEW E0.5 SITE DETAILS E1.0 DEMOLITION E2.0 NEW LIGHTING SECTION D E2.1 NEW LIGHTING SECTION E E3.0 NEW POWER SECTION D E3.1 NEW POWER SECTION E E4.0 NEW FIRE ALARM SECTION D E4.1 NEW FIRE ALARM SECTION E MECHANICAL M0.0 COVER SHEET M1.0 FIRST FLOOR OVERALL PLAN SEE SHEET A0.2 - CODE ANALYSIS

Upload: others

Post on 11-May-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

CIVIL ENGINEERING STRUCTURAL ENGINEERING ARCHITECTURAL MECHANICAL ENGINEERING PLUMBING ENGINEERING FIRE PROTECTION ENGINEERING ELECTRICAL ENGINEERING
THE HL TURNER GROUP INC. THE HL TURNER GROUP INC. THE HL TURNER GROUP INC. TURNER BUILDING SCIENCE, LLC. TURNER BUILDING SCIENCE, LLC. TURNER BUILDING SCIENCE, LLC. BLW ENGINEERS, INC.
T:603.228.1122
T:207.583.4571
T:978.486.4301
F:603.228.1124
F:207.583.4572
F:978.428.0067
CONSTRUCTED BY:
CONCORD NH HARRISON ME LYNDONVILLE VT LITTLETON MA NEW HAVEN CT
27 LOCKE ROAD CONCORD, NEW HAMPSHIRE 03301 T:603.228.1122 / F:603.228.1126
W:www.hlturner.com
THE H.L. TURNER GROUP Inc.
ARCHITECT OF RECORD:
HL TURNER GROUP, INC.
8 / 2 5 / 2 0 1 6 9 :2 5 :5 4 A M
CITY WIDE COMMUNITY CENTER
C O V E R S H E E T
14 Canterbury Rd Concord, NH 03301
08/25/2016
4401
DRAWING LIST SHEET
NUMBER DRAWING TITLE 00 GENERAL COVER COVER SHEET 01 CIVIL CX GENERAL NOTES AND LEGENDS C1.0 EXISTING CONDITIONS PLANS C1.1 SITE PREPARATION PLANS C2.0 SITE PLAN C3.0 GRADING PLAN C4.0 UTILITY PLAN C6.0 SITE DETAILS C7.0 UTILITY DETAILS 02 STRUCTURAL S1.1 FOUNDATION PLAN S2.2 ROOF FRAMING PLAN 03 ARCHITECTURAL A0.1 LEGEND & GENERAL INFORMATION A0.2 CODE ANALYSIS A1.1 EXISTING CONDITIONS FLOOR PLAN - AREA A (16,488
SQ. FT.) A1.2 EXISTING CONDITIONS FLOOR PLAN AREA B
(5,372 SQ. FT.) A1.3 EXISTING CONDITIONS FLOOR PLAN AREA C (6,989
SQ. FT.) A1.4 PROPOSED FLOOR PLAN A1.5 ROOF PLAN A1.6 ENLARGED PLAN A1.7 ENLARGED PLAN A3.2 NEW CONSTRUCTION EXTERIOR ELEVATIONS A4.1 BUILDING SECTIONS & WALL SECTIONS 04 PLUMBING P0.0 COVER SHEET P1.1 FIRST FLOOR OVERALL PLAN 06 ELECTRICAL E0.1 LEGEND E0.2 SCHEDULES AND POWER RISER DIAGRAM E0.3 FIRE ALARM RISER E0.4 SITE PLAN DEMOLITION AND NEW E0.5 SITE DETAILS E1.0 DEMOLITION E2.0 NEW LIGHTING SECTION D E2.1 NEW LIGHTING SECTION E E3.0 NEW POWER SECTION D E3.1 NEW POWER SECTION E E4.0 NEW FIRE ALARM SECTION D E4.1 NEW FIRE ALARM SECTION E MECHANICAL M0.0 COVER SHEET M1.0 FIRST FLOOR OVERALL PLAN
SEE SHEET A0.2 - CODE ANALYSIS
W1
1
A1.1
1
A1.1
1
A1.1
DIMENSIONED WOOD (CONTINUOUS)
FINISH WOOD PLYWOOD
CONCRETE
STEEL
ALUMINUM
COLUMN LINE DESIGNATOR
DOOR NUMBER
RE: A40 SHEETS FOR INTERIOR FINISHES
SHEET NO. (WHERE FIRST DRAWN OR CUT)
DETAIL SECTION NUMBER
INTERIOR ELEVATION ELEVATION NUMBER
? ? ?
?
GENERAL NOTES
1. PROVIDE TYPE MOISTURE RESISTANT GYPSUM BOARD AT AREAS ADJACENT TO SINKS, TOILETS, AND OTHER PLUMBING FIXTURES OR WET AREAS UNLESS NOTED OTHERWISE.
2. REFER TO ROOM FINISH SCHEDULE FOR WALL FINISH, FLOOR FINISH, AND BASE INFORMATION UNLESS NOTED OTHERWISE.
3. REFER TO ROOM FINISH SCHEDULE OR REFLECTED CEILING PLANS (IF APPLICABLE) FOR CEILING HEIGHTS AND FINISHES UNLESS NOTED OTHERWISE.
4. ALL DIMENSIONS AT DOORS, WINDOWS, OR OTHER OPENINGS ARE TO CENTERLINE OF OPENING, UNLESS NOTED OTHERWISE.
5. SEE SPECIFICATIONS AND ROOM FINISH SCHEDULE FOR SIGNAGE, CONTROL AND EQUIPMENT FINISH/COLOR DESIGNATIONS UNLESS NOTED OTHERWISE.
6. ALL DISTURBED SITE AREAS TO BE REGRADED, SEEDED, PLANTED, & MULCHED PER PLANS UNLESS NOTED OTHERWISE.
7. ALL REVISED FINAL GRADING TO SLOPE A MINIMUM OF 5 % DOWN AWAY FROM ALL STRUCTURES FOR 6' FROM THE BUILDING PERIMETER UNLESS NOTED OTHERWISE.
1. ALL DEMOLITION DIMENSIONS INDICATED ARE PLUS OR MINUS UNLESS NOTED OTHERWISE. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO BID SUBMISSION.
2. DEMOLITION FOR THIS PROJECT IS INDICATED, BUT NOT LIMITED TO WHAT IS SHOWN ON A DRAWING AND ANY ADDITIONAL DEMOLITION REQUIRED TO COMPLETE CONSTRUCTION IS A REQUIREMENT OF THIS CONTRACT. COORDINAT WITH ALL CONTRACT DOCUMENTS AND SPECIFICATIONS.
3. ANY EXISTING COMPONENTS, WHICH INTERFERE WITH PROPOSED WORK SHALL BE REMOVED AS REQUIRED.
4. DEMOLITION AND CONSTRUCTION AREAS SHALL BE BARRICADED AS NECESSARY OR AS DIRECTED BY ARCHITECT, CONSTRUCTION MANAGER, OR OWNER. DUST CONTROL SYSTEMS SHALL BE ERECTED AS NECESSARY UNLESS NOTED OTHERWISE.
5. REMOVE ALL EXISTING MECHANICAL, ELECTRICAL, HEATING UNITS, PLUMBING FIXTURES, WIRING, AND PIPING, ETC. NOT REQUIRED, UNLESS NOTED OTHERWISE.
DEMOLITION NOTES:
CONSTRUCTION NOTES:
ELEVATION REFERENCE / KEY CROSS REFERENCE ELEVATION KEY BETWEEN DISCIPLINES
?
ACC DF
EQUIPMENT PERMITTED IN SHADED AREA
H/C ACCESSIBLE DRINKING FOUNTAIN (D.F.) SEE PLAN & SECTION VIEW FOR H/C ACCESSIBLE HEIGHTS)
TYPICAL MARKER, CHALK OR TACK BOARD
ELEC. & TELEPHONE RECEPTACLES
THERMOSTATS, SWITCHES & DOOR KNOBS
ELEVATOR DESIGNATIONS SHALL BE 60" A.F.F.x2"W. W/BRAILLE MOUNTED TO BOTH JAMBS OF EACH ELEVATOR
INSULATED PIPES
ELEVATOR CONTROLS (BUTTONS 3/4" MIN.)
FIRE ALARM STATION AUDIBLE ELEVATOR LANTERNS (ELEVATOR DESIGNATIONS SHALL BE 60" A.F.F. x 2"H w/ BRAILLE MOUNTED TO BOTH JAMBS OF EACH ELEVATOR)
CODE CARD
ROOM SIGNAGE (UPPER CASE LETTERS 1/32" x 5/8"H MIN. - 2" MAX. w/ GRADE 2 BRAILLE AT BASE, USING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY MIN. PICTOGRAM HGT. 6")
STANDARD CABINET DIMENSIONS
MOP RECEPTOR SEE MECH.
24" MIN. SINK AND RANGE 15" MIN. OTHERS
(3) MOP HOLDER CLAMPS
1-1/4" TO 1-1/2" DIA. w/ KURLED FINISH
FIN FL
ACC SHELF
FIN FL
H/C SINK
PAPER TOWEL DISPENSER
BACK WALL
TYPICAL U.N.O. / NTS ACCESSIBLE RAMP DETAILS
ELEVATION WALL CONFIGURATION
ELEVATION CURB CONFIGURATION
SIDE WALL TO LEFT OR RIGHT
MAXIMUM RAMP SLOPE = 1:12 MAXIMUM RAMP RISE FOR ANY RUN = 30" MINIMUM RAMP LANDING SIZE = 36"W x 60"L (if ramp direction changes = 60"W x 60"L)
SECTION
TYPICAL - U.N.O. MANEUVERING CLEARANCES AT DOORS
SEE RAMP DETAILS FOR SPECIFIC HANDRAIL & BALUSTER CONFIGURATIONS
PULL SIDE
PUSH SIDE
LATCH SIDE APPROACH
LATCH SIDE APPROACH
SLIDING AND FOLDING DOORS
HINGE SIDE APPROACH
PUSH SIDE
35 " m
TOILET PAPER DISPENSER
SANITARY NAPKIN DISPOSAL
TYPICAL U.N.O. / NTS
BABY CHANGING STATION
7"- 9"
PROVIDE (2) LINES OF 2X WOOD BLOCKING ALONG ALL PRESENT AND KNOWNFUTURE ACCESSORY SUPPORT LOCATIONS. COORDINATE LOCATIONS WITH OWNER, ARCHITECT AND CONTRACTOR UNLESS OTHERWISE NOTED.
60" min. clear
60" min. clear
39" TO 41"
(SURFACE COLOR) BRAILLE LETTERS AND NUMBERS
INSERT SLATS
ACRYLIC BACK
VINYL TAPE
STAIR
A220A220
THIS IS A REPRESENTATION OF THE INTENT OF SIGNAGE. EXACT NAMES, LOCATIONS, COLORS, AND PATTERNS TO BE SELECTED DURING THE SUBMITTAL PROCESS. ARCHITECT TO CHOOSE FROM FULL PRODUCT LINE OF COLORS , PATTERNS AND STYLES.
B C D
A
A = SIGN LOCATION
EQ. EQ.EQ.
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd. Concord, New Hampshire 03301
t:603.228.1122 hlturner.com
ARCHITECTS ENGINEERS
BUILDING SCIENTISTS
2 3
CITY OF CONCORD
SCHEMATIC DESIGN 08/25/2016
NIC NOT IN CONTRACT NBN NUMBERED NOTE NFM NEW FLOOR MAT NTS NOT TO SCALE NWRK NO WORK
O OH OVER HEAD OSB ORIENTED STRAND BOARD
P PAFS POWDER ACTUATED
FASTENINGS PC PORCELAIN CERAMIC PLAM PLASTIC LAMINATE PNT PAINT (ED) P.T. PRESSURE TREATED PWD PLYWOOD
R RCP REFLECTED CEILING PLAN REF REFERENCE RD ROOF DRAIN RMV REMOVE (D) (ABLE) RO ROUGH OPENING R-PNT REPAINT R-CLR REFINISH CLEAR
S SAFB SOUND ATTENDING
FIBERGLASS BATTS SCT STRUCTURAL CLAY TILE SD STATIC DISSIPATIVE SF SQUARE FOOT SGT STRUCTURAL GLAZED TILE SLG SALVAGED SP SPEAKER SP ED SPECIAL EDUCATION SSACT SUSPENDED SLOPED ACT STL STEEL ST, STO STORAGE SUSP SUSPENDED SVNL FIBERGLASS SHEET VINYL
T TB TACK BOARD TG TEMPERED GLASS THRM THERMALLY BROKEN TYP TYPICAL THRM THERMALLY BREAK
U UH UNIT HEATER U.N.O. UNLESS NOTED
OTHERWISE
V VCT VINYL COMPOSITION TILE VEST VESTIBULE VERT VERTICAL VIF VERIFY IN FIELD
W WB WHITE BOARD WC WATER CLOSET W/ WITH WD WOOD WG WIRE GLASS
FEC FIRE EXTINGUISHER CABINET
FIN FINISH (ED) FINFL, FINISH FLOOR F.F. FINISH FLOOR FL FLOORING FLG FLASHING FND FOUNDATION FR FRAME (D) (ING) FRP FIBERGLASS REINFORCED
PLASTIC FT FIRE TREATED FTG FOOTING FUT FUTURE FXD FIXED
G GA GAUGE GV GALVANIZED GALV GALVANIZED GL GLASS, GLAZING GWB GYPSUM WALL BOARD GYP GYPSUM
H HC HANDICAPPED
ACCESSIBLE HDWD HARD WOOD HGT HEIGHT HM HOLLOW METAL HORIZ HORIZONTAL
I IN INCH (ES) INCAND INCANDESCENT IAQ INDOOR AIR QUALITY ID INSIDE DIAMETER INS INSULATE (D) (ION) INSUL INSULATE (D) (ION) INT INTERIOR
L LAV LAVATORY LF LINEAR FOOT LTL LINTEL
M MAS MASONRY MAT MATERIAL (S) MATL MATERIAL (S) MAX MAXIMUM MB MARKER BOARD MDO MEDIUM DENSITY
OVERLAY MECH MECHANICAL MFR MANUFACTURER MO MASONRY OPENING MTL METAL MISC MISCELLANEOUS MR MIRROR MRGWB MOISTURE RESISTANT
GWB MUL MULLION
A ADJ ADJUSTABLE AFF ABOVE FINISH FLOOR ACM ASBESTOS CONTAINING
MATERIAL ACT ACOUSTIC CEILING TILE ALT ALTERNATE ALUM ALUMINUM AMD ACOUSTICAL METAL
DECKING AP ACCESS PANEL
B BM BEAM BLKG BLOCKING BRK BRICK BLDG BUILDING BO BY OWNER
C CB CHALKBOARDS CFMF COLD FORM METAL
FRAMING CLG CEILING CLR CLEAR FINISH CHT CEILING HEIGHT CONC CONCRETE CMU CONCRETE MASONRY
UNIT CONT CONTINUE (OUS) CONTR CONTRACTOR CJ CONTROL JOINT CORR CORRIDOR CP CONTROL PANEL CR CLASS ROOM CRS COURSES CT CERAMIC TILE CWB CEMENTITIOUS WALL
BOARD
D DBL DOUBLE DEMO DEMOLITION DN DOWN DTL DETAIL DWG DRAWING
E EA EACH EDF ELECTRONIC DRINKING
FOUNTAIN EFM EXISTING FLOOR MAT EJ EXPANSION JOINT ELEC ELECTRIC (AL) ELEV ELEVATION EP ELECTRICAL PANEL EQ EQUAL ETR EXISTING TO REMAIN EXIST EXISTING EXPSTR EXPOSED STRUCTURE EXT EXTERIOR
F FA FIRE ALARM FE FIRE EXTINGUISHER
1 Date 1 Revision 1
0' 8'
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd. Concord, New Hampshire 03301
t:603.228.1122 hlturner.com
ARCHITECTS ENGINEERS
BUILDING SCIENTISTS
2 3
CITY OF CONCORD
GENERAL FLOOR PLAN NOTES 1. FINISH FLOOR ELEVATION = XXX'-X". -(X) =
DISTANCE OF GRADE BELOW FFE IN INCHES. + X = DISTANCE OF GRADE ABOVE FFE IN INCHES. FINISH FLOOR ELEVATION OF BUILDING IS REFERENCED AS ARCHITECTURAL DATUM ELEVATION 100'-0", AND IS MEASURED FROM THE TOP OF CONCRETE SLAB. SEE CIVIL DRAWINGS FOR ELEVATIONS BASED ON TOPOGRAPHIC DATUM.
2. DO NOT SCALE DRAWINGS 3. THE CONTRACTOR SHALL PROVIDE BLOCKING
FOR ALL MILLWORK, MECHANICAL FIXTURES, PLUMBING FIXTURES AND ELECTRICAL DEVICES AS REQUIRED.
4. ALL LUMBER IN DIRECT CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED INCLUDING ALL SILL PLATES FOR WOOD STUD WALLS.
5. CM SHALL REVIEW PRIOR TO INSTALLATION ANY CONFLICT OF ENGINEERING TRADE DEVICES (I.E. FIRE ALARM STROBES) WITH ARCHITECTURAL DETAILS AND BRING THOSE DISCREPANCIES TO THE ARCHITECT FOR REVIEW.
6. ALL DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE, FACE OF MASONRY OR CENTER OF OPENING, U.N.O.
7. COORDINATE MISCELLANEOUS STEEL REQUIREMENTS FOR MOUNTING / HANGING OWNER SUPPLIED EQUIPMENT.
8. BUILDER SHALL COORDINATE ALL ROUGH OPENING DIMENSIONS WITH FLASHING DETAILS.
X
GENERAL PARTITION NOTES 1. SEE SHEET A0.4 FOR PARTITION TYPES.
PROVIDE MOISTURE RESISTANT GWB ON ALL WALLS & CEILINGS IN ALL BATHROOM, RESTROOM & SHOWER LOCATIONS, & WITHIN 4'-0" OF SINKS, TOILETS AND SHOWERS.
2. ALL DIMENSIONS ARE TO FACE OF STUD OR CENTER OF OPENING UNLESS NOTED OTHERWISE.
3. INSTALL ALL FIRE RATED WALL & CEILING ASSEMBLIES FOLLOWING DETAILS. FASTENERS AND SPACING IN ACCORDANCE WITH UL FIRE RESISTANCE DIRECTORY.
4. EXTEND GWB TO UNDERSIDE OF FLOOR OR DECK ON FIRE BARRIERS. GWB SHALL TERMINATE AT UNDERSIDE OF DECK AT FIRE PARTITIONS UNLESS OTHERWISE DETAILED.
5. STAGGER ALL ELECTRICAL DEVICES IN FIRE BARRIERS & FIRE PARTITIONS.
6. INSTALL APPROVED FIRE STOP MATERIAL AT ALL PENETRATIONS THROUGH FIRE RATED WALLS & FLOORS.
7. ALL WIRE PENETRATIONS THROUGH FIRE RATED WALLS PLATES & FLOORS SHALL BE SEALED WITH FIRE STOP SEALANT.
8. METALLIC PIPE PENETRATIONS SHALL BE SEALED AROUND PENETRATIONS WITH FIRE STOP SEALANT AT FIRE RATED WALLS, FLOORS & CEILINGS.
9. NON-METALLIC PIPE PENETRATIONS SHALL BE SEALED WITH FIRE STOP COLLAR AROUND PENETRATION WITH FIRE STOP SEALANT.
10. CM SHALL REVIEW PRIOR TO INSTALLATION ANY CONFLICT OF ENGINEERING TRADE DEVICES (I.E. FIRE ALARM STROBES) WITH ARCHITECTURAL DETAILS AND BRING THOSE DISCREPANCIES TO THE ARCHITECT FOR REVIEW.
CONSTRUCTION LEGEND
- NEW PARTITIONS
CONSTRUCTION NOTE LEGEND
1 -
2 -
3 -
4 -
5 -
6 -
7 -
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
A
B
C
D
E
F
G
H
I
9" VCTCPT. 9" VCTCPT. 9" VCTCPT.
C.B.
35' - 5 1/8"
7' - 9" 4' - 2 3/4" 7' - 9" 4' - 2 3/4" 7' - 9"
35' - 6 1/4" 23' - 6 1/2" 35' - 5 3/4" 35' - 6" 35' - 6"
26 ' -
35' - 6"
22' - 10"
34' - 6 1/4" 35' - 6 5/16"
7' - 9" 4' - 2 3/4" 7' - 9" 4' - 2 3/4" 7' - 9" 1' - 4"
8' - 6
J
A
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd. Concord, New Hampshire 03301
t:603.228.1122 hlturner.com
ARCHITECTS ENGINEERS
BUILDING SCIENTISTS
2 3
CITY OF CONCORD
A1.1
DP
KD
DP
4401
GENERAL FLOOR PLAN NOTES 1. FINISH FLOOR ELEVATION = XXX'-X". -(X) =
DISTANCE OF GRADE BELOW FFE IN INCHES. + X = DISTANCE OF GRADE ABOVE FFE IN INCHES. FINISH FLOOR ELEVATION OF BUILDING IS REFERENCED AS ARCHITECTURAL DATUM ELEVATION 100'-0", AND IS MEASURED FROM THE TOP OF CONCRETE SLAB. SEE CIVIL DRAWINGS FOR ELEVATIONS BASED ON TOPOGRAPHIC DATUM.
2. DO NOT SCALE DRAWINGS 3. THE CONTRACTOR SHALL PROVIDE BLOCKING
FOR ALL MILLWORK, MECHANICAL FIXTURES, PLUMBING FIXTURES AND ELECTRICAL DEVICES AS REQUIRED.
4. ALL LUMBER IN DIRECT CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED INCLUDING ALL SILL PLATES FOR WOOD STUD WALLS.
5. CM SHALL REVIEW PRIOR TO INSTALLATION ANY CONFLICT OF ENGINEERING TRADE DEVICES (I.E. FIRE ALARM STROBES) WITH ARCHITECTURAL DETAILS AND BRING THOSE DISCREPANCIES TO THE ARCHITECT FOR REVIEW.
6. ALL DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE, FACE OF MASONRY OR CENTER OF OPENING, U.N.O.
7. COORDINATE MISCELLANEOUS STEEL REQUIREMENTS FOR MOUNTING / HANGING OWNER SUPPLIED EQUIPMENT.
8. BUILDER SHALL COORDINATE ALL ROUGH OPENING DIMENSIONS WITH FLASHING DETAILS.
X
GENERAL PARTITION NOTES 1. SEE SHEET A0.4 FOR PARTITION TYPES.
PROVIDE MOISTURE RESISTANT GWB ON ALL WALLS & CEILINGS IN ALL BATHROOM, RESTROOM & SHOWER LOCATIONS, & WITHIN 4'-0" OF SINKS, TOILETS AND SHOWERS.
2. ALL DIMENSIONS ARE TO FACE OF STUD OR CENTER OF OPENING UNLESS NOTED OTHERWISE.
3. INSTALL ALL FIRE RATED WALL & CEILING ASSEMBLIES FOLLOWING DETAILS. FASTENERS AND SPACING IN ACCORDANCE WITH UL FIRE RESISTANCE DIRECTORY.
4. EXTEND GWB TO UNDERSIDE OF FLOOR OR DECK ON FIRE BARRIERS. GWB SHALL TERMINATE AT UNDERSIDE OF DECK AT FIRE PARTITIONS UNLESS OTHERWISE DETAILED.
5. STAGGER ALL ELECTRICAL DEVICES IN FIRE BARRIERS & FIRE PARTITIONS.
6. INSTALL APPROVED FIRE STOP MATERIAL AT ALL PENETRATIONS THROUGH FIRE RATED WALLS & FLOORS.
7. ALL WIRE PENETRATIONS THROUGH FIRE RATED WALLS PLATES & FLOORS SHALL BE SEALED WITH FIRE STOP SEALANT.
8. METALLIC PIPE PENETRATIONS SHALL BE SEALED AROUND PENETRATIONS WITH FIRE STOP SEALANT AT FIRE RATED WALLS, FLOORS & CEILINGS.
9. NON-METALLIC PIPE PENETRATIONS SHALL BE SEALED WITH FIRE STOP COLLAR AROUND PENETRATION WITH FIRE STOP SEALANT.
10. CM SHALL REVIEW PRIOR TO INSTALLATION ANY CONFLICT OF ENGINEERING TRADE DEVICES (I.E. FIRE ALARM STROBES) WITH ARCHITECTURAL DETAILS AND BRING THOSE DISCREPANCIES TO THE ARCHITECT FOR REVIEW.
CONSTRUCTION LEGEND
- NEW PARTITIONS
CONSTRUCTION NOTE LEGEND
CPT.
CPT.
36' - 1 1/2"
9" 8' - 3" 8' - 3" 8' - 3" 8' - 3" 2' - 2"
8' - 9
12 ' -
21' - 6 3/4"
17' - 7 1/2"
23
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd. Concord, New Hampshire 03301
t:603.228.1122 hlturner.com
ARCHITECTS ENGINEERS
BUILDING SCIENTISTS
2 3
CITY OF CONCORD
A1.2
DP
KD
DP
4401
Scale:A1.2 1/8" = 1'-0" 2 MECHANICAL ROOM (AREA B)
Scale:A1.2 3 3D VIEW MECH. ROOM
N
N
CPT.CPT.
32' - 1" 31' - 9 1/2"
65' - 4 1/2" 8' - 11" 9' - 0" 12' - 3 9/16" 16' - 9 7/8"
6' - 11 1/4" 36' - 3"
35' - 0" 34' - 11 1/2" 8' - 11" 29' - 2" 29' - 2"
23 ' -
GENERAL FLOOR PLAN NOTES 1. FINISH FLOOR ELEVATION = XXX'-X". -(X) =
DISTANCE OF GRADE BELOW FFE IN INCHES. + X = DISTANCE OF GRADE ABOVE FFE IN INCHES. FINISH FLOOR ELEVATION OF BUILDING IS REFERENCED AS ARCHITECTURAL DATUM ELEVATION 100'-0", AND IS MEASURED FROM THE TOP OF CONCRETE SLAB. SEE CIVIL DRAWINGS FOR ELEVATIONS BASED ON TOPOGRAPHIC DATUM.
2. DO NOT SCALE DRAWINGS 3. THE CONTRACTOR SHALL PROVIDE BLOCKING
FOR ALL MILLWORK, MECHANICAL FIXTURES, PLUMBING FIXTURES AND ELECTRICAL DEVICES AS REQUIRED.
4. ALL LUMBER IN DIRECT CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED INCLUDING ALL SILL PLATES FOR WOOD STUD WALLS.
5. CM SHALL REVIEW PRIOR TO INSTALLATION ANY CONFLICT OF ENGINEERING TRADE DEVICES (I.E. FIRE ALARM STROBES) WITH ARCHITECTURAL DETAILS AND BRING THOSE DISCREPANCIES TO THE ARCHITECT FOR REVIEW.
6. ALL DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE, FACE OF MASONRY OR CENTER OF OPENING, U.N.O.
7. COORDINATE MISCELLANEOUS STEEL REQUIREMENTS FOR MOUNTING / HANGING OWNER SUPPLIED EQUIPMENT.
8. BUILDER SHALL COORDINATE ALL ROUGH OPENING DIMENSIONS WITH FLASHING DETAILS.
X
GENERAL PARTITION NOTES 1. SEE SHEET A0.4 FOR PARTITION TYPES.
PROVIDE MOISTURE RESISTANT GWB ON ALL WALLS & CEILINGS IN ALL BATHROOM, RESTROOM & SHOWER LOCATIONS, & WITHIN 4'-0" OF SINKS, TOILETS AND SHOWERS.
2. ALL DIMENSIONS ARE TO FACE OF STUD OR CENTER OF OPENING UNLESS NOTED OTHERWISE.
3. INSTALL ALL FIRE RATED WALL & CEILING ASSEMBLIES FOLLOWING DETAILS. FASTENERS AND SPACING IN ACCORDANCE WITH UL FIRE RESISTANCE DIRECTORY.
4. EXTEND GWB TO UNDERSIDE OF FLOOR OR DECK ON FIRE BARRIERS. GWB SHALL TERMINATE AT UNDERSIDE OF DECK AT FIRE PARTITIONS UNLESS OTHERWISE DETAILED.
5. STAGGER ALL ELECTRICAL DEVICES IN FIRE BARRIERS & FIRE PARTITIONS.
6. INSTALL APPROVED FIRE STOP MATERIAL AT ALL PENETRATIONS THROUGH FIRE RATED WALLS & FLOORS.
7. ALL WIRE PENETRATIONS THROUGH FIRE RATED WALLS PLATES & FLOORS SHALL BE SEALED WITH FIRE STOP SEALANT.
8. METALLIC PIPE PENETRATIONS SHALL BE SEALED AROUND PENETRATIONS WITH FIRE STOP SEALANT AT FIRE RATED WALLS, FLOORS & CEILINGS.
9. NON-METALLIC PIPE PENETRATIONS SHALL BE SEALED WITH FIRE STOP COLLAR AROUND PENETRATION WITH FIRE STOP SEALANT.
10. CM SHALL REVIEW PRIOR TO INSTALLATION ANY CONFLICT OF ENGINEERING TRADE DEVICES (I.E. FIRE ALARM STROBES) WITH ARCHITECTURAL DETAILS AND BRING THOSE DISCREPANCIES TO THE ARCHITECT FOR REVIEW.
CONSTRUCTION LEGEND
- NEW PARTITIONS
CONSTRUCTION NOTE LEGEND
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd. Concord, New Hampshire 03301
t:603.228.1122 hlturner.com
ARCHITECTS ENGINEERS
BUILDING SCIENTISTS
2 3
CITY OF CONCORD
A1.3
DP
KD
DP
4401
UP
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
A
B
C
D
E
F
G
H
I
20
21
M
L
K
J
N
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd. Concord, New Hampshire 03301
t:603.228.1122 hlturner.com
ARCHITECTS ENGINEERS
BUILDING SCIENTISTS
2 3
CITY OF CONCORD
CCCW ROOM LIST
Number Name Area Department
101 VEST. 103 SF CIRCULATION 102 LOBBY 2142 SF CIRCULATION 103 VEST. 95 SF CIRCULATION 104 AUDITORIUM 2394 SF MULTIPURPOSE 105 OFFICE 93 SF ADMINISTRATIVE OFFICES 106 OFFICE 117 SF ADMINISTRATIVE OFFICES 107 OFFICE 124 SF ADMINISTRATIVE OFFICES 108 RECEP. 261 SF ADMINISTRATIVE OFFICES 109 STOR. 39 SF RESTROOMS & FACILITIES 110 STORAGE 338 SF RESTROOMS & FACILITIES 111 SERVING
KITCHEN 619 SF MULTIPURPOSE
244 SF RESTROOMS & FACILITIES
113 CUST. 47 SF RESTROOMS & FACILITIES 114 ELEC. 98 SF RESTROOMS & FACILITIES 115 SERVER/ IT 129 SF RESTROOMS & FACILITIES 116 M. LOCKERS 230 SF RESTROOMS & FACILITIES 117 SHOWERS 184 SF RESTROOMS & FACILITIES 118 MEN'S 303 SF RESTROOMS & FACILITIES 119 WOMEN'S 302 SF RESTROOMS & FACILITIES 120 SHOWERS 185 SF RESTROOMS & FACILITIES 121 W. LOCKERS 230 SF RESTROOMS & FACILITIES 122 GYMNASIUM 8325 SF MULTIPURPOSE 122A STOR. 34 SF RESTROOMS & FACILITIES 122B STORAGE 67 SF RESTROOMS & FACILITIES 122C STORAGE 69 SF RESTROOMS & FACILITIES 124 PROGRAM
ROOM 1107 SF PROGRAM SPACE
124A STO. 115 SF PROGRAM SPACE 125 PROGRAM
ROOM 1122 SF PROGRAM SPACE
125A STO. 101 SF PROGRAM SPACE 126 STO. 296 SF RESTROOMS & FACILITIES 127 MAINT. 274 SF RESTROOMS & FACILITIES 127 STO. 85 SF RESTROOMS & FACILITIES 128 GIRLS 203 SF RESTROOMS & FACILITIES 129 BOYS 248 SF RESTROOMS & FACILITIES 130 OFFICE 286 SF ADMINISTRATIVE OFFICES 131 CONFERENCE 340 SF ADMINISTRATIVE OFFICES 132 OFFICE 150 SF ADMINISTRATIVE OFFICES 133 OFFICE 124 SF ADMINISTRATIVE OFFICES 134 OFFICE 184 SF ADMINISTRATIVE OFFICES 135 GROUP
EXERCISE 1232 SF FITNESS
RESTROOM 102 SF RESTROOMS & FACILITIES
137 SENIORS 919 SF SENIORS 137A STO. 92 SF SENIORS 137B OFFICE 92 SF SENIORS 138 MULTIPURPO
SE ROOM 1235 SF MULTIPURPOSE
138A LIBRARY STO. 296 SF MULTIPURPOSE 139 GROUP
EXERCISE 1110 SF FITNESS
139A STO. 113 SF FITNESS 196 CORRIDOR 538 SF CIRCULATION 197 CORRIDOR 784 SF CIRCULATION 198 CORRIDOR 511 SF CIRCULATION 199 CORRIDOR 866 SF CIRCULATION
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
A
B
C
D
E
F
G
H
I
20
21
22
19
23
M
L
K
J
N
GENERAL ROOF PLAN NOTES
- FASCIA SCULPER
- EXHAUST FAN
X
R1 -
1. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD AND NOTIFY ARCHITECT OF ANY DISCREPANCIES BEFORE PROCEEDING WITH CONSTRUCTION.
2. ROOF INSULATION SHALL BE R-25 MINIMUM.
SC
DS
EX
ES
CD
R3 30" x 36" PAINTED ROOF HATCH
R4 -
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd. Concord, New Hampshire 03301
t:603.228.1122 hlturner.com
ARCHITECTS ENGINEERS
BUILDING SCIENTISTS
2 3
CITY OF CONCORD
Scale:A1.5 1/16" = 1'-0" 1 ROOF
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
A
B
C
D
E
F
G
H
I
GENERAL FLOOR PLAN NOTES 1. FINISH FLOOR ELEVATION = XXX'-X". -(X) =
DISTANCE OF GRADE BELOW FFE IN INCHES. + X = DISTANCE OF GRADE ABOVE FFE IN INCHES. FINISH FLOOR ELEVATION OF BUILDING IS REFERENCED AS ARCHITECTURAL DATUM ELEVATION 100'-0", AND IS MEASURED FROM THE TOP OF CONCRETE SLAB. SEE CIVIL DRAWINGS FOR ELEVATIONS BASED ON TOPOGRAPHIC DATUM.
2. DO NOT SCALE DRAWINGS 3. THE CONTRACTOR SHALL PROVIDE BLOCKING
FOR ALL MILLWORK, MECHANICAL FIXTURES, PLUMBING FIXTURES AND ELECTRICAL DEVICES AS REQUIRED.
4. ALL LUMBER IN DIRECT CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED INCLUDING ALL SILL PLATES FOR WOOD STUD WALLS.
5. CM SHALL REVIEW PRIOR TO INSTALLATION ANY CONFLICT OF ENGINEERING TRADE DEVICES (I.E. FIRE ALARM STROBES) WITH ARCHITECTURAL DETAILS AND BRING THOSE DISCREPANCIES TO THE ARCHITECT FOR REVIEW.
6. ALL DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE, FACE OF MASONRY OR CENTER OF OPENING, U.N.O.
7. COORDINATE MISCELLANEOUS STEEL REQUIREMENTS FOR MOUNTING / HANGING OWNER SUPPLIED EQUIPMENT.
8. BUILDER SHALL COORDINATE ALL ROUGH OPENING DIMENSIONS WITH FLASHING DETAILS.
X
GENERAL PARTITION NOTES 1. SEE SHEET A0.4 FOR PARTITION TYPES.
PROVIDE MOISTURE RESISTANT GWB ON ALL WALLS & CEILINGS IN ALL BATHROOM, RESTROOM & SHOWER LOCATIONS, & WITHIN 4'-0" OF SINKS, TOILETS AND SHOWERS.
2. ALL DIMENSIONS ARE TO FACE OF STUD OR CENTER OF OPENING UNLESS NOTED OTHERWISE.
3. INSTALL ALL FIRE RATED WALL & CEILING ASSEMBLIES FOLLOWING DETAILS. FASTENERS AND SPACING IN ACCORDANCE WITH UL FIRE RESISTANCE DIRECTORY.
4. EXTEND GWB TO UNDERSIDE OF FLOOR OR DECK ON FIRE BARRIERS. GWB SHALL TERMINATE AT UNDERSIDE OF DECK AT FIRE PARTITIONS UNLESS OTHERWISE DETAILED.
5. STAGGER ALL ELECTRICAL DEVICES IN FIRE BARRIERS & FIRE PARTITIONS.
6. INSTALL APPROVED FIRE STOP MATERIAL AT ALL PENETRATIONS THROUGH FIRE RATED WALLS & FLOORS.
7. ALL WIRE PENETRATIONS THROUGH FIRE RATED WALLS PLATES & FLOORS SHALL BE SEALED WITH FIRE STOP SEALANT.
8. METALLIC PIPE PENETRATIONS SHALL BE SEALED AROUND PENETRATIONS WITH FIRE STOP SEALANT AT FIRE RATED WALLS, FLOORS & CEILINGS.
9. NON-METALLIC PIPE PENETRATIONS SHALL BE SEALED WITH FIRE STOP COLLAR AROUND PENETRATION WITH FIRE STOP SEALANT.
10. CM SHALL REVIEW PRIOR TO INSTALLATION ANY CONFLICT OF ENGINEERING TRADE DEVICES (I.E. FIRE ALARM STROBES) WITH ARCHITECTURAL DETAILS AND BRING THOSE DISCREPANCIES TO THE ARCHITECT FOR REVIEW.
CONSTRUCTION LEGEND
- NEW PARTITIONS
CONSTRUCTION NOTE LEGEND
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd. Concord, New Hampshire 03301
t:603.228.1122 hlturner.com
ARCHITECTS ENGINEERS
BUILDING SCIENTISTS
2 3
CITY OF CONCORD
UP
GENERAL FLOOR PLAN NOTES 1. FINISH FLOOR ELEVATION = XXX'-X". -(X) =
DISTANCE OF GRADE BELOW FFE IN INCHES. + X = DISTANCE OF GRADE ABOVE FFE IN INCHES. FINISH FLOOR ELEVATION OF BUILDING IS REFERENCED AS ARCHITECTURAL DATUM ELEVATION 100'-0", AND IS MEASURED FROM THE TOP OF CONCRETE SLAB. SEE CIVIL DRAWINGS FOR ELEVATIONS BASED ON TOPOGRAPHIC DATUM.
2. DO NOT SCALE DRAWINGS 3. THE CONTRACTOR SHALL PROVIDE BLOCKING
FOR ALL MILLWORK, MECHANICAL FIXTURES, PLUMBING FIXTURES AND ELECTRICAL DEVICES AS REQUIRED.
4. ALL LUMBER IN DIRECT CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED INCLUDING ALL SILL PLATES FOR WOOD STUD WALLS.
5. CM SHALL REVIEW PRIOR TO INSTALLATION ANY CONFLICT OF ENGINEERING TRADE DEVICES (I.E. FIRE ALARM STROBES) WITH ARCHITECTURAL DETAILS AND BRING THOSE DISCREPANCIES TO THE ARCHITECT FOR REVIEW.
6. ALL DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE, FACE OF MASONRY OR CENTER OF OPENING, U.N.O.
7. COORDINATE MISCELLANEOUS STEEL REQUIREMENTS FOR MOUNTING / HANGING OWNER SUPPLIED EQUIPMENT.
8. BUILDER SHALL COORDINATE ALL ROUGH OPENING DIMENSIONS WITH FLASHING DETAILS.
X
GENERAL PARTITION NOTES 1. SEE SHEET A0.4 FOR PARTITION TYPES.
PROVIDE MOISTURE RESISTANT GWB ON ALL WALLS & CEILINGS IN ALL BATHROOM, RESTROOM & SHOWER LOCATIONS, & WITHIN 4'-0" OF SINKS, TOILETS AND SHOWERS.
2. ALL DIMENSIONS ARE TO FACE OF STUD OR CENTER OF OPENING UNLESS NOTED OTHERWISE.
3. INSTALL ALL FIRE RATED WALL & CEILING ASSEMBLIES FOLLOWING DETAILS. FASTENERS AND SPACING IN ACCORDANCE WITH UL FIRE RESISTANCE DIRECTORY.
4. EXTEND GWB TO UNDERSIDE OF FLOOR OR DECK ON FIRE BARRIERS. GWB SHALL TERMINATE AT UNDERSIDE OF DECK AT FIRE PARTITIONS UNLESS OTHERWISE DETAILED.
5. STAGGER ALL ELECTRICAL DEVICES IN FIRE BARRIERS & FIRE PARTITIONS.
6. INSTALL APPROVED FIRE STOP MATERIAL AT ALL PENETRATIONS THROUGH FIRE RATED WALLS & FLOORS.
7. ALL WIRE PENETRATIONS THROUGH FIRE RATED WALLS PLATES & FLOORS SHALL BE SEALED WITH FIRE STOP SEALANT.
8. METALLIC PIPE PENETRATIONS SHALL BE SEALED AROUND PENETRATIONS WITH FIRE STOP SEALANT AT FIRE RATED WALLS, FLOORS & CEILINGS.
9. NON-METALLIC PIPE PENETRATIONS SHALL BE SEALED WITH FIRE STOP COLLAR AROUND PENETRATION WITH FIRE STOP SEALANT.
10. CM SHALL REVIEW PRIOR TO INSTALLATION ANY CONFLICT OF ENGINEERING TRADE DEVICES (I.E. FIRE ALARM STROBES) WITH ARCHITECTURAL DETAILS AND BRING THOSE DISCREPANCIES TO THE ARCHITECT FOR REVIEW.
CONSTRUCTION LEGEND
- NEW PARTITIONS
CONSTRUCTION NOTE LEGEND
12' - 6"12' - 6"11 ' -
34 ' -
4"
21' - 4 1/2"21' - 4 15/16"21' - 4 5/8"20' - 2 5/16" 21' - 8 1/2"
0' 8'
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd. Concord, New Hampshire 03301
t:603.228.1122 hlturner.com
ARCHITECTS ENGINEERS
BUILDING SCIENTISTS
2 3
CITY OF CONCORD
GENERAL ELEVATION NOTES
6 ALUMINUM STOREFRONT
7 METAL FASCIA
1. FINISH FLOOR ELEVATION = XXX'-X". -(X) = DISTANCE OF GRADE BELOW FFE IN INCHES. + X = DISTANCE OF GRADE ABOVE FFE IN INCHES. FINISH FLOOR ELEVATION OF BUILDING IS REFERENCED AS ARCHITECTURAL DATUM ELEVATION 100'-0", AND IS MEASURED FROM THE TOP OF CONCRETE SLAB. SEE CIVIL DRAWINGS FOR ELEVATIONS BASED ON TOPOGRAPHIC DATUM.
2. DO NOT SCALE DRAWINGS.
3. REFER TO MECHANICAL DRAWINGS FOR LOCATIONS OF LOUVERS AND VENTS. CONFIRM FINAL POSITION WITH ARCHITEECT PRIOR TO ORDERING.
X - CONSTRUCTION NOTE. SEE LEGEND BELOW
8 PRE-CAST SILL
7
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd. Concord, New Hampshire 03301
t:603.228.1122 hlturner.com
ARCHITECTS ENGINEERS
BUILDING SCIENTISTS
2 3
CITY OF CONCORD
GENERAL ELEVATION NOTES
6 ALUMINUM STOREFRONT
7 METAL FASCIA
1. FINISH FLOOR ELEVATION = XXX'-X". -(X) = DISTANCE OF GRADE BELOW FFE IN INCHES. + X = DISTANCE OF GRADE ABOVE FFE IN INCHES. FINISH FLOOR ELEVATION OF BUILDING IS REFERENCED AS ARCHITECTURAL DATUM ELEVATION 100'-0", AND IS MEASURED FROM THE TOP OF CONCRETE SLAB. SEE CIVIL DRAWINGS FOR ELEVATIONS BASED ON TOPOGRAPHIC DATUM.
2. DO NOT SCALE DRAWINGS.
3. REFER TO MECHANICAL DRAWINGS FOR LOCATIONS OF LOUVERS AND VENTS. CONFIRM FINAL POSITION WITH ARCHITEECT PRIOR TO ORDERING.
X - CONSTRUCTION NOTE. SEE LEGEND BELOW
8 PRE-CAST SILL
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd. Concord, New Hampshire 03301
t:603.228.1122 hlturner.com
ARCHITECTS ENGINEERS
BUILDING SCIENTISTS
2 3
CITY OF CONCORD
FF 347.33'
M. LOCKERS
NEW ROOF DECK 360.33'
8' - 0" 6" 26' - 0" 1' - 0" OFFICE OFFICE MAINT.
11 9/
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd. Concord, New Hampshire 03301
t:603.228.1122 hlturner.com
ARCHITECTS ENGINEERS
BUILDING SCIENTISTS
2 3
CITY OF CONCORD
2
3
4
5
6
7
D
E
F
G
H
I
20
21
22
19
23
F10.5
F10.5
F10.5
F8
F4
F5
F4
F5
F4
F5
F4
24" FTG 14" WALL
T.O.F. = 343.33' T.O.W. = 347.33'
14 " W
AL L
24 " F
T.O. SLAB = 347.33'
4" SLAB ON GRADE W/ (1) - LAYER 6 x 6 - W2.0 x W2.0 WWF LOCATED AT CENTER
FOOTING SCHEDULE MARK SIZE REINFORCING NOTES
F4 4'-0" X 4'-0" X 1'-0"t #5'S @ 12" O.C. , E.W., T&B F4.2 4'-0" X 4'-0" X 1'-0"t #5'S @ 12" O.C. , E.W., T&B F5 5'-0" X 5'-0" X 1'-0"t #5'S @ 12" O.C. , E.W., T&B F8 8'-0" X 8'-0" X 1'-6"t #6'S @ 12" O.C. , E.W., T&B F10.5 10'-6" X 10'-6" X 1'-6"t #6'S @ 12" O.C. , E.W., T&B
Scale:S1.1 1/8" = 1'-0" 1 FOUNDATION PLAN
0' 8'
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd. Concord, New Hampshire 03301
t:603.228.1122 hlturner.com
ARCHITECTS ENGINEERS
BUILDING SCIENTISTS
2 3
CITY OF CONCORD
W14X22
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd. Concord, New Hampshire 03301
t:603.228.1122 hlturner.com
ARCHITECTS ENGINEERS
BUILDING SCIENTISTS
2 3
CITY OF CONCORD
C5 HSS5X5X3/8 C6 HSS6X6X3/8
PROJECT TITLE / ADDRESS:
SMC
DHB/JDP
DHB/JDP
4401
© "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd.
BUILDING SCIENTISTS
1 2
3 4
CITY OF CONCORD
M0.0 COVER SHEET
AutoCAD SHX Text
1. GENERAL NOTES, SYMBOLS LIST AND DETAILS ARE APPLICABLE TO GENERAL NOTES, SYMBOLS LIST AND DETAILS ARE APPLICABLE TO DRAWINGS MARKED M-#. SOME ABBREVIATIONS AND SYMBOLS MAY NOT BE APPLICABLE TO THIS PARTICULAR PROJECT - THEY ARE PROVIDED FOR GENERAL REFERENCE ONLY. 2. PLANS ARE NOT INTENDED TO SHOW EVERY DETAIL, DROP, RISE, OR PLANS ARE NOT INTENDED TO SHOW EVERY DETAIL, DROP, RISE, OR FITTING. DUCT AND PIPING LOCATIONS INDICATED ARE APPROXIMATE. DETERMINE EXACT LOCATIONS IN THE FIELD. 3. COORDINATE WORK OF THIS DIVISION WITH THAT OF OTHER COORDINATE WORK OF THIS DIVISION WITH THAT OF OTHER DIVISIONS. 4. COORDINATE WORK WITH THE TRADES INVOLVED. PROVIDE OFFSETS IN COORDINATE WORK WITH THE TRADES INVOLVED. PROVIDE OFFSETS IN PIPING AND DUCTS (INCLUDING DIVIDED DUCTS) AND TRANSITIONS AROUND OBSTRUCTIONS AT NO ADDITIONAL COST TO THE OWNER. 5. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS OF AIR DEVICES WHERE APPLICABLE. 6. VERIFY EQUIPMENT CONNECTIONS WITH MANUFACTURER'S CERTIFIED VERIFY EQUIPMENT CONNECTIONS WITH MANUFACTURER'S CERTIFIED DRAWINGS. VERIFY AND PROVIDE DUCT AND PIPE TRANSITIONS TO FURNISHED EQUIPMENT. FIELD VERIFY AND COORDINATE DIMENSIONS BEFORE FABRICATION. 7. PROVIDE ACCESS PANELS, WHERE REQUIRED, TO SERVICE DAMPERS, PROVIDE ACCESS PANELS, WHERE REQUIRED, TO SERVICE DAMPERS, HEATERS, VALVES AND CONCEALED MECHANICAL EQUIPMENT. PROVIDE ACCESS PANELS UPSTREAM OF ELBOWS WITH TURNING VANES. 8. INSTALL EQUIPMENT, PIPING AND DUCTWORK AS REQUIRED TO INSTALL EQUIPMENT, PIPING AND DUCTWORK AS REQUIRED TO PROVIDE A VIBRATION-FREE INSTALLATION, AND TO FACILITATE EQUIPMENT ACCESS AS REQUIRED BY EQUIPMENT MANUFACTURER. 9. DUCTWORK SHALL BE GALVANIZED STEEL UNLESS NOTED OTHERWISE, DUCTWORK SHALL BE GALVANIZED STEEL UNLESS NOTED OTHERWISE, CONSTRUCTED AND INSTALLED ACCORDING TO LATEST SMACNA STANDARDS FOR PRESSURE CLASS AS SPECIFIED. EXPOSED ROUND OR OVAL DUCT SHALL BE SPIRAL SEAM. 10. DUCT SIZES INDICATED ARE "INSIDE-CLEAR" DIMENSIONS. INCREASE DUCT SIZES INDICATED ARE "INSIDE-CLEAR" DIMENSIONS. INCREASE OUTSIDE DIMENSIONS TO ALLOW FOR THICKNESS OF INSIDE ACOUSTIC LINING AND OTHER OBSTRUCTIONS. 11. ACOUSTICALLY LINE DUCTWORK WHERE INDICATED AND SPECIFIED. ACOUSTICALLY LINE DUCTWORK WHERE INDICATED AND SPECIFIED. DUCTWORK TO BE LINED INCLUDES (BUT IS NOT LIMITED TO) TRANSFER DUCTS, AND SUPPLY & RETURN DUCTS FROM FAN-POWERED UNIT CONNECTIONS TO AT LEAST 10 FEET AWAY INCLUDING AT LEAST ONE 90-DEGREE ELBOW. AT VAV BOXES, ACOUSTICALLY LINE RECTANGULAR SUPPLY TO AT LEAST 10 FEET DOWNSTREAM UNLESS OTHERWISE INDICATED. 12. DIFFUSER SIZES INDICATED ARE NECK SIZES; REGISTER AND GRILLE DIFFUSER SIZES INDICATED ARE NECK SIZES; REGISTER AND GRILLE SIZE ARE NOMINAL. 13. PROVIDE FLEXIBLE DUCT CONNECTIONS ON DUCTS CONNECTING TO PROVIDE FLEXIBLE DUCT CONNECTIONS ON DUCTS CONNECTING TO FANS AND OTHER VIBRATING EQUIPMENT, AND TO AIR HANDLING UNITS WHICH ARE NOT INTERNALLY ISOLATED. ELECTRICALLY-GROUND DUCTS ACROSS CONNECTIONS WITH FLEXIBLE COPPER GROUNDING STRAPS. 14. SEAL DUCT JOINTS, SEAMS AND PENETRATIONS WITH SPECIFIED DUCT SEAL DUCT JOINTS, SEAMS AND PENETRATIONS WITH SPECIFIED DUCT SEALANT OR SILICONE, PER SMACNA SEAL CLASS A AND PER APPLICABLE CODES. 15. DUCT ELBOWS SHALL BE LONG-RADIUS ELBOWS EXCEPT WHERE DUCT ELBOWS SHALL BE LONG-RADIUS ELBOWS EXCEPT WHERE SPACE DOES NOT PERMIT OR AS SPECIFICALLY INDICATED OTHERWISE. 16. PROVIDE 45 OR BELLMOUTH TAKE-OFFS FOR RUNOUTS. PROVIDE 45° OR BELLMOUTH TAKE-OFFS FOR RUNOUTS.17. PAINT THE INSIDE OF DUCTWORK VISIBLE TO OCCUPANTS THROUGH PAINT THE INSIDE OF DUCTWORK VISIBLE TO OCCUPANTS THROUGH AN OPENING OR TERMINAL DEVICE, FLAT BLACK. 18. PROVIDE AT LEAST THREE-ELBOW SWINGS FOR PIPE TAKE-OFFS. PROVIDE AT LEAST THREE-ELBOW SWINGS FOR PIPE TAKE-OFFS. 19. PROVIDE CLAMPS, OFFSETS, EXPANSION JOINTS, ANCHORS, AND PROVIDE CLAMPS, OFFSETS, EXPANSION JOINTS, ANCHORS, AND GUIDES AS NECESSARY TO PREVENT STRESS ON PIPING. 20. PITCH PIPING 1 INCH PER 20 FEET IN DIRECTION OF FLOW TO PITCH PIPING 1 INCH PER 20 FEET IN DIRECTION OF FLOW TO DRAINS AND VENTS. 21. PROVIDE CIRCUIT SETTER BALANCING VALVES AT SYSTEM LOOP PROVIDE CIRCUIT SETTER BALANCING VALVES AT SYSTEM LOOP RETURNS AND AT RETURN RISERS. PROVIDE SHUT-OFF VALVES AT SYSTEM LOOP SUPPLIES AND SUPPLY RISERS. 22. PROVIDE VENTS AT HIGH POINTS IN PIPING SYSTEMS AND DRAIN PROVIDE VENTS AT HIGH POINTS IN PIPING SYSTEMS AND DRAIN VALVES AT LOW POINTS. MANUAL VENTS IN MAINS SHALL CONSIST OF A LINE-SIZED AIR CHAMBER, AN ELBOW DOWNWARD, AND BALL VALVE WITH GARDEN HOSE END AND BRASS GASKETED CAP. 23. INSULATE PIPING AS SPECIFIED. PERFORM TESTS SPECIFIED BEFORE INSULATE PIPING AS SPECIFIED. PERFORM TESTS SPECIFIED BEFORE INSULATING. 24. MOUNT ROOM THERMOSTATS AND SENSORS AT ACCESSIBLE HEIGHT MOUNT ROOM THERMOSTATS AND SENSORS AT ACCESSIBLE HEIGHT AS SPECIFIED IN DIVISION 23 TEMPERATURE CONTROL SYSTEM SPECIFICATION SECTION(S). 25. CONTROL WIRE AND CONDUIT SHALL COMPLY WITH NEC AND DIVISION CONTROL WIRE AND CONDUIT SHALL COMPLY WITH NEC AND DIVISION 26 ELECTRICAL SPECIFICATIONS. 26. ELECTRICAL CONTRACTOR SHALL WIRE DUCT SMOKE DETECTORS TO ELECTRICAL CONTRACTOR SHALL WIRE DUCT SMOKE DETECTORS TO THE FIRE ALARM PANEL. SMOKE DETECTORS MOUNTED IN ROOFTOP UNITS SHALL BE FACTORY-INSTALLED AND SHALL SHUT UNIT DOWN WHEN SENSING SMOKE. 27. PLUMBING WORK: IN ACCORDANCE WITH STATE AND LOCAL CODES. PLUMBING WORK: IN ACCORDANCE WITH STATE AND LOCAL CODES. 28. PROVIDE AN AIR GAP OR BREAK AS REQUIRED BY CODE ON PROVIDE AN AIR GAP OR BREAK AS REQUIRED BY CODE ON EQUIPMENT DRAINS PIPED TO FLOOR DRAINS OR OTHER RECEPTORS.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ANGLE GLOBE VALVE
AutoCAD SHX Text
MANUAL AIR VENT
AutoCAD SHX Text
AutoCAD SHX Text
PRESSURE REDUCING VALVE
AutoCAD SHX Text
SWING CHECK VALVE
AutoCAD SHX Text
AutoCAD SHX Text
SUPPLY DUCT UP
AutoCAD SHX Text
SUPPLY DUCT DOWN
AutoCAD SHX Text
R or E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CEILING SUPPLY DIFFUSER
AutoCAD SHX Text
AutoCAD SHX Text
NON-SLAM CHECK VALVE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LOWER VALUE - MBH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ELECTRIC OR ELECTRONIC
AutoCAD SHX Text
ELECTRIC OR ELECTRONIC
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PROJECT TITLE / ADDRESS:
AS NOTED
© "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd.
BUILDING SCIENTISTS
1 2
3 4
P: \44
01 C
ity of
C on
co rd
C ity
-W ide
C om
mu nit
CITY OF CONCORD
M1.0 FIRST FLOOR
GRAPHIC SCALE
CAMUS ADVANTUS CONDENSING BOILERS. VENTING FOR EACH BOILER: 6-INCH POLYPROPYLENE LISTED SYSTEM THRU ROOF. COMBUSTION AIR 8-INCH PVC THRU ROOF
AutoCAD SHX Text
AutoCAD SHX Text
HOT WATER PIPING TO TERMINAL HEATING UNITS, GLYCOL PIPING TO ROOFTOP UNIT HEATING COILS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MULTIPURPOSE ROOM AND SERVING KITCHEN ON A SHARED ROOFTOP HEATING/COOLING HVAC SYSTEM, SO CATERING FOOD ODORS STAY IN THE AREA SERVED. PERIMETER FINTUBE FOR NIGHT HEATING AND COMFORT WITH EXISTING WALLS WITH LOW INSULATION
AutoCAD SHX Text
GYMNASIUM SYSTEM: ROOFTOP HEATING-ONLY HVAC UNIT WITH SUPPLY DUCTED TO BELOW BLEACHERS, DISCHARGING IN DISPLACEMENT-VENTILATION MANNER
AutoCAD SHX Text
LOCKER ROOM & TOILET HVAC: HEATING ONLY (POSSIBLE RADIANT FLOOR) WITH HEAT-RECOVERY VENTILATION
AutoCAD SHX Text
CORE AREAS: ROOFTOP HEATING/COOLING HVAC UNIT. HIGHER ROOF IN LOBBY ALLOWS CONCEALED DUCTS. LOW ROOF IN EXISTING AREAS REQUIRES EXPOSED DUCTWORK. AREAS WITH EXISTING WALLS MAY HAVE PERIMETER FINTUBE FOR NIGHT HEATING
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
INDIVIDUAL-ROOM HEATING/COOLING HVAC UNITS FOR THIS WING. LOW ROOF DOESN'T ALLOW FOR LARGE DUCTS BETWEEN ROOMS. SMALLER VENTILATION DUCTS MAY INTERCONNECT SOME ROOMS. LARGE GROUP ROOMS REQUIRE SUBSTANTIAL VENTILATION, WHICH MAY HAVE CO2-BASED DEMAND CONTROL. PERIMETER FINTUBE FOR NIGHT HEATING AND COMFORT WITH EXISTING WALLS WITH LOW INSULATION
AutoCAD SHX Text
INDIVIDUAL-ROOM HEATING/COOLING HVAC UNITS FOR THIS WING. LOW ROOF DOESN'T ALLOW FOR LARGE DUCTS BETWEEN ROOMS. SMALLER VENTILATION DUCTS MAY INTERCONNECT SOME ROOMS. LARGE GROUP ROOMS REQUIRE SUBSTANTIAL VENTILATION, WHICH MAY HAVE CO2-BASED DEMAND CONTROL. PERIMETER FINTUBE FOR NIGHT HEATING AND COMFORT WITH EXISTING WALLS WITH LOW INSULATION
COPYRIGHT : THE H.L. TURNER GROUP INC. 2016
PROJECT TITLE / ADDRESS:
SMC
DHB/JDP
DHB/JDP
4401
© "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd.
BUILDING SCIENTISTS
1 2
3 4
CITY OF CONCORD
P0.0 COVER SHEET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
1. PIPING INDICATED IS DIAGRAMMATIC ONLY. DETERMINE EXACT LOCATIONS IN FIELD, WITH APPROVAL. PIPING INDICATED IS DIAGRAMMATIC ONLY. DETERMINE EXACT LOCATIONS IN FIELD, WITH APPROVAL. 2. REVIEW ARCHITECTURAL, STRUCTURAL, HVAC, ELECTRICAL, AND SITE DRAWINGS BEFORE STARTING WORK REVIEW ARCHITECTURAL, STRUCTURAL, HVAC, ELECTRICAL, AND SITE DRAWINGS BEFORE STARTING WORK TO FAMILIARIZE YOURSELF WITH THE DETAILS OF CONSTRUCTION, IN ADDITION TO COORDINATING WITH OTHER TRADES, TO ELIMINATE POSSIBLE CONFLICTS. VERIFY REQUIREMENTS IN PLUMBING WALLS PRIOR TO WALL CONSTRUCTION. 3. OBTAIN REQUIRED PERMITS AND PAY RELATED FEES. OBTAIN REQUIRED PERMITS AND PAY RELATED FEES. 4. PROVIDE NECESSARY PIPING, EQUIPMENT, SUPPORTS AND ANY EQUIPMENT NOT INDICATED ON PROVIDE NECESSARY PIPING, EQUIPMENT, SUPPORTS AND ANY EQUIPMENT NOT INDICATED ON DRAWINGS OR CALLED FOR IN SPECIFICATIONS AND NECESSARY TO PROVIDE A COMPLETE FUNCTIONAL SYSTEM PER THE STATE PLUMBING CODE. 5. PROVIDE ACCESS TO EQUIPMENT REQUIRING PERIODIC SERVICE AND MAINTENANCE. PROVIDE ACCESS TO EQUIPMENT REQUIRING PERIODIC SERVICE AND MAINTENANCE. 6. PLUMBING WORK SHALL BE INSTALLED IN ACCORDANCE WITH STATE AND LOCAL CODES. PLUMBING WORK SHALL BE INSTALLED IN ACCORDANCE WITH STATE AND LOCAL CODES. 7. PIPES THROUGH FIRE WALLS: PIPES THROUGH FIRE WALLS: REQUIRED FIRE RESISTANCE RATING OF FLOORS, WALLS, AND CEILINGS SHALL BE MAINTAINED WHERE PIPE PENETRATIONS ARE MADE. INSTALL FIRE STOPPING IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. PROVIDE INTUMESCENT COLLARS ON PLASTIC PIPING. 8. PITCH WATER LINES TO DRAIN. PITCH WATER LINES TO DRAIN. 9. PROVIDE SHUT OFF VALVES ON WATER PIPING TO INDIVIDUAL FIXTURES AND EQUIPMENT. PROVIDE SHUT OFF VALVES ON WATER PIPING TO INDIVIDUAL FIXTURES AND EQUIPMENT. 10. PROVIDE DIELECTRIC COUPLINGS BETWEEN DISSIMILAR MATERIALS. PROVIDE DIELECTRIC COUPLINGS BETWEEN DISSIMILAR MATERIALS. 11. CONDUCT TESTS PRIOR TO INSULATING, CONCEALING, OR BACKFILLING. CONDUCT TESTS PRIOR TO INSULATING, CONCEALING, OR BACKFILLING. 12. SEE SPECIFICATIONS FOR INSULATION REQUIREMENTS ON POTABLE WATER PIPING. SEE SPECIFICATIONS FOR INSULATION REQUIREMENTS ON POTABLE WATER PIPING. 13. INSTALL HORIZONTAL RUNS OF PIPING AS HIGH AS POSSIBLE. PROVIDE 1/2" DRAIN VALVES WITH INSTALL HORIZONTAL RUNS OF PIPING AS HIGH AS POSSIBLE. PROVIDE 1/2" DRAIN VALVES WITH HOSE CONNECTION AT LOW POINTS. 14. PROVIDE AN AIR GAP OR BREAK AS REQUIRED BY CODE ON EQUIPMENT DRAINS PIPED TO FLOOR PROVIDE AN AIR GAP OR BREAK AS REQUIRED BY CODE ON EQUIPMENT DRAINS PIPED TO FLOOR DRAINS. 15. CHANGES FROM PLASTIC TO METAL PIPING SHALL BE MADE WITH MECHANICAL JOINT FITTINGS WITH CHANGES FROM PLASTIC TO METAL PIPING SHALL BE MADE WITH MECHANICAL JOINT FITTINGS WITH O-RING, GASKET SEAL OR CRIMP FITTINGS. THREADED CONNECTIONS ARE NOT ALLOWED. 16. DRAWINGS ARE DIAGRAMMATIC ONLY. COORDINATE EXACT LOCATIONS, MOUNTING HEIGHTS OF DRAWINGS ARE DIAGRAMMATIC ONLY. COORDINATE EXACT LOCATIONS, MOUNTING HEIGHTS OF EQUIPMENT, AND ROUTING OF PIPING WITH THE EQUIPMENT REQUIREMENTS AND FIELD CONDITIONS. 17. PROVIDE INCIDENTAL ACCESSORIES NECESSARY TO MAKE THE PLUMBING WORK COMPLETE, FUNCTIONAL PROVIDE INCIDENTAL ACCESSORIES NECESSARY TO MAKE THE PLUMBING WORK COMPLETE, FUNCTIONAL AND READY FOR OPERATION. 18. SEE PLUMBING SPECIFICATIONS FOR HANGER DETAILS AND OTHER REQUIREMENTS.SEE PLUMBING SPECIFICATIONS FOR HANGER DETAILS AND OTHER REQUIREMENTS.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WALL HUNG FLUSHOMETER TOILET, 1.28 GPF, 1-1/2" TOP SPUD INLET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WALL HUNG FLUSHOMETER TOILET, 1.28 GPF, 1-1/2" TOP SPUD INLET MOUNTED AT ADA BARRIER-FREE HEIGHT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WALL MOUNTED FLUSH VALVE URINAL MOUNTED AT ADA BARRIER-FREE HEIGHT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WALL MOUNT LAVATORY, 20"X18" NOMINAL SIZE, VITREOUS CHINA, WITH BACK AND SIDE SPLASH SHIELDS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TERRAZZO MOP BASIN, 36"W x 24"L x 10"H OVERALL, 3-INCH CAST BRASS DRAIN WITH STAINLESS STEEL DOME STRAINER
AutoCAD SHX Text
STERN-WILLIAMS T-10-VB WITH VACUUM BREAKER, TOP BRACE, AND BUCKET HOOK
AutoCAD SHX Text
T-40 MOP HANGER, T-35 HOSE & WALL HOOK, V-70 VINYL BUMPERGUARDS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GELCOAT SURFACE SHOWER STALL, 36" x 36" NOMINAL SIZE, BARRIER FREE, CENTER DRAIN, CURTAIN ROD, SHOWER CUTRAIN
AutoCAD SHX Text
AutoCAD SHX Text
ADAHS HAND SHOWER WITH NON-POSITIVE SHUTOFF BUTTON, INTEGRAL SERVICE STOPS, 6-FOOT METAL HOSE, 48-INCH SLIDE BAR
AutoCAD SHX Text
AutoCAD SHX Text
LIGHT GRAY GRANITE
AutoCAD SHX Text
DUAL-HEIGHT WALL HUNG WATER COOLER, 8.0 GPH, WITH BOTTLE FILLING STATION ON LOW SIDE, LOW AND HIGH SIDE LOCATION PER ARCHITECTURAL, FILTER AND SPARE FILTER CARTRIDGE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WALL FAUCET, METAL WHEEL HANDLE, FIELD-TESTABLE DUAL-CHECK BACKFLOW PREVENTER ON OUTLET, 3/4" THREAD INLET. CHROME PLATED (TOILET/LOCKER ROOMS), ROUGH BRASS (WORKROOMS & GARAGES)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CONCEALED NON-FREEZE KEY OPERATED WALL HYDRANT WITH NICKEL BRONZE BOX AND DOOR, CHROME PLATED HYDRANT FACE, INTEGRAL VACUUM BREAKER, AND WALL CLAMP
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EPOXY COATED CAST IRON FLOOR DRAIN WITH ANCHOR FLANGE, REVERSIBLE CLAMPING COLLAR WITH PRIMARY & SECONDARY WEEPHOLES, 8-IN. DIA. HEAVY-DUTY ADJUSTABLE ROUND NICKEL BRONZE STRAINER, AND NO-HUB (STANDARD) OUTLET WITH TRAP PRIMER CONNECTION
AutoCAD SHX Text
AutoCAD SHX Text
EPOXY COATED CAST IRON FLOOR DRAIN WITH ANCHOR FLANGE, REVERSIBLE CLAMPING COLLAR WITH PRIMARY & SECONDARY WEEPHOLES, 7-IN. DIA. MEDIUM-DUTY ADJUSTABLE NICKEL BRONZE STRAINER, 4x9" OVAL NICKEL BRONZE FUNNEL, AND NO-HUB (STANDARD) OUTLET WITH TRAP PRIMER CONNECTION.
AutoCAD SHX Text
POWDER COATED CAST IRON BI-FUNCTIONAL ROOF DRAIN, CONCENTRIC PRIMARY OUTLET, CENTER OVERFLOW OUTLET, NO-HUB OUTLET, UNDERDECK CLAMP, DECK FLANGE, ADJUSTABLE EXTENSION
AutoCAD SHX Text
AutoCAD SHX Text
EPOXY COATED CAST IRON FLOOR CLEANOUT WITH 5" DIA. ROUND ADJUSTABLE GASKETED HEAVY-DUTY NICKEL BRONZE TOP, REMOVABLE GAS-TIGHT GASKETED BRASS CLEANOUT PLUG
AutoCAD SHX Text
WALL CLEANOUT WITH COUNTERSUNK THREADED BRASS PLUG, STAINLESS STEEL ACCESS COVER, VANDAL-PROOF STAINLESS STEEL SCREW
AutoCAD SHX Text
AutoCAD SHX Text
1. SEE DIVISION 23 CONTROLS FOR OCC/UNOCC OPERATION OF PUMP
AutoCAD SHX Text
AutoCAD SHX Text
DOMESTIC CONNECTIONS (IN.)
AutoCAD SHX Text
BOILER CONNECTIONS (IN.)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
1. PRECHARGE IN FIELD TO SYSTEM COLD STATIC PRESSURE. ASME CONSTRUCTION.
AutoCAD SHX Text
BACKFLOW PREVENTER SCHEDULE
AutoCAD SHX Text
AutoCAD SHX Text
1. WITH BALL VALVES, STRAINER WHERE INDICATED, AIR GAP FITTING, AND DRAIN ELBOW
AutoCAD SHX Text
2. PIPE ATMOSPHERIC VENT TO FLOOR DRAIN WITH AIR GAP
AutoCAD SHX Text
PROJECT TITLE / ADDRESS:
AS NOTED
© "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd.
BUILDING SCIENTISTS
1 2
3 4
P: \44
01 C
ity of
C on
co rd
C ity
-W ide
C om
mu nit
CITY OF CONCORD
P1.0 FIRST FLOOR
GRAPHIC SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WATER ENTRANCE WITH METER FOR 1960s WING IF REQUIRED FOR FLUSHING FLOWS
AutoCAD SHX Text
EXIST 6"CW BELOW GRADE FOR FIRE SUPPRESSION SYSTEM, SEE CIVIL
AutoCAD SHX Text
AutoCAD SHX Text
RL BELOW GRADE TO 10 FEET OUTSIDE BUILDING, SEE CIVIL FOR CONTINUATION
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PROVIDE REPLACEMENT FIXTURES IN TOILET ROOMS, WITH AUTOMATIC FLUSHES & FAUCETS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MECHANICAL ROOM INCLUDING DOMESTIC WATER ENTRANCE WITH METER, DOMESTIC HOT WATER HEATING AND RECIRCULATION TO ENTIRE BUILDING
AutoCAD SHX Text
EXIST FLAT ROOFS: PROVIDE REPLACEMENT ROOF DRAINS, CONNECT TO EXIST RL PIPE RISERS
AutoCAD SHX Text
DEMOLITION THIS WING: REMOVE STAFF TOILET ROOM FIXTURES, STAFF BREAK ROOM FIXTURES, AND CLASSROOM SINKS, AND ASSOCIATED PIPING INCLUDING VENTS THRU ROOF. REMOVE DOMESTIC WATER PIPING ABOVE GRADE SERVING FIXTURES WHERE DRINKING WATER MAY BE OBTAINED
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXTERIOR WALL HYDRANTS WITH RECESSED BOXES AND LOOSE-TEE-KEY OPERATORS, LOCATED FOR CONVENIENCE FOR LANDSCAPING
AutoCAD SHX Text
JANITOR'S CLOSET: 36"X24" MOP BASIN ON FLOOR FOR USE WITH MOP BUCKETS
AutoCAD SHX Text
EXIST SAN & RL RUN BELOW CORRIDOR FLOOR WITH FLOOR CLEANOUTS
AutoCAD SHX Text
EXTERIOR WALL HYDRANTS WITH RECESSED BOXES AND LOOSE-TEE-KEY OPERATORS, LOCATED FOR CONVENIENCE FOR LANDSCAPING
AutoCAD SHX Text
AutoCAD SHX Text
WORK OF THIS DRAWING EXTENDS TO 10 FEET OUTSIDE BUILDING, TYP.
AutoCAD SHX Text
PROVIDE REPLACEMENT AIR COMPRESSOR FOR SPRINKLER DRY-PIPE SYSTEM, AT ENTRANCE IN CRAWLSPACE. DRY-PIPE SYSTEM SERVES UNHEATED ATTIC
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXIST JANITOR SINK
AutoCAD SHX Text
EXIST RL PIPING CROSSES BELOW CORRIDOR CEILING AND DROPS INTO FLOOR IN CORNER OF ROOM ACROSS THE CORRIDOR, TYP.
AutoCAD SHX Text
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd.
BUILDING
SCIENTISTS
ISSUE:
1 2
3 4
CITY OF CONCORD
NONE
ELECTRICAL
LEGEND
JP
SWD
SWD
1
0 '
8 '
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd.
BUILDING
SCIENTISTS
ISSUE:
1 2
3 4
CITY OF CONCORD
NONE
ELECTRICAL
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd.
BUILDING
SCIENTISTS
ISSUE:
1 2
3 4
CITY OF CONCORD
NONE
ELECTRICAL
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd.
BUILDING
SCIENTISTS
ISSUE:
1 2
3 4
CITY OF CONCORD
1"=40'-0"
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd.
BUILDING
SCIENTISTS
ISSUE:
1 2
3 4
CITY OF CONCORD
AS NOTED
ELECTRICAL
DETAILS
JP
SWD
SWD
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
A
B
C
D
E
F
G
H
I
STOVE
REF.
WD
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd.
BUILDING
SCIENTISTS
ISSUE:
1 2
3 4
CITY OF CONCORD
1/8"=1'-0"
D E
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
A
B
C
D
E
F
G
H
OFFICE
OFFICE
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd.
BUILDING
SCIENTISTS
ISSUE:
1 2
3 4
CITY OF CONCORD
1/8"=1'-0"
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd.
BUILDING
SCIENTISTS
ISSUE:
1 2
3 4
CITY OF CONCORD
1/8"=1'-0"
D E
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
A
B
C
D
E
F
G
H
OFFICE
OFFICE
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd.
BUILDING
SCIENTISTS
ISSUE:
1 2
3 4
CITY OF CONCORD
1/8"=1'-0"
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd.
BUILDING
SCIENTISTS
ISSUE:
1 2
3 4
CITY OF CONCORD
1/8"=1'-0"
D E
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
A
B
C
D
E
F
G
H
OFFICE
OFFICE
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd.
BUILDING
SCIENTISTS
ISSUE:
1 2
3 4
CITY OF CONCORD
1/8"=1'-0"
PROJECT TITLE / ADDRESS:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
c "Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only - except as excluded by individual specifications (e.g. Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others."
27 Locke Rd.
BUILDING
SCIENTISTS
ISSUE:
1 2
3 4
CITY OF CONCORD
1/8"=1'-0"
Sheets
Sheets
4401_071816_Arch_Central_DanH - - Sheet - A1-5 - ROOF PLAN.pdf
Sheets
Sheets
Sheets
Sheets
4401_071816_Arch_Central_DanH - - Sheet - A3-2 - NEW CONSTRUCTION EXTERIOR ELEVATIONS.pdf
Sheets
4401_071816_Arch_Central_DanH - - Sheet - A3-4 - AERIAL VIEW FROM CANTERBURY RD.pdf
Sheets
4401_071816_Arch_Central_DanH - - Sheet - A4-1 - BUILDING SECTIONS & WALL SECTIONS.pdf
Sheets
4401_071816_Arch_Central_DanH - Sheet - A0-1 - LEGEND & GENERAL INFORMATION.pdf
Sheets
Sheets
Sheets
A1.1 - EXISTING CONDITIONS FLOOR PLAN - AREA A (16,488 SQ. FT.)
4401_071816_Arch_Central_DanH - Sheet - A1-2 - EXISTING CONDITIONS FLOOR PLAN AREA B (5,372 SQ- FT-).pdf
Sheets
A1.2 - EXISTING CONDITIONS FLOOR PLAN AREA B (5,372 SQ. FT.)
4401_071816_Arch_Central_DanH - Sheet - A1-3 - EXISTING CONDITIONS FLOOR PLAN AREA B.pdf
Sheets
A1.3 - EXISTING CONDITIONS FLOOR PLAN AREA C (6,989 SQ. FT.)
4401_071816_Arch_Central_DanH - Sheet - A1-4 - Sheet - A1-4 - PROPOSED FLOOR PLAN - Sheet - A1-4 - PROPOSED FLOOR PLAN.pdf
Sheets
Sheets
4401 2016 08 23 Concord Community Center_Structural
Sheets
M0-0