Cirprotec Surge ProtectionModular, Pluggable and High Capacity Surge Protection Solutions for Commercial and Industrial applications
POWER DISTRIBUTION AND PROTECTION
Sales 1300 NHP NHP nhp.com.auNHP Electrical Engineering Products Pty Ltd
2
At NHP we’re solely committed to serving the needs of our customers in the industrial electrical industry. From concept design through to installation and after sales service, we are confident we have the experience and expertise to exceed your expectations and ensure you get the best result for your project. How? By combining Partnerships, Agility, Knowledge and Scalability, NHP can offer 100% Australian owned service that forms the ultimate choice in our industry.
PARTNERSHIPS:When you choose NHP you gain a valuable industry partner. You gain access to an exclusive network of quality global suppliers who, together with NHP, can achieve an engineered solution for your industrial electrical application. A partnership with NHP promises to last, working together with you to offer complete trust, assurance and peace of mind.
AGILITY: At NHP we understand your project needs and know that these needs can often change throughout the lifecycle of a project. With a seamless combination of local and technical support backed by around the clock service and local stock, NHP has the agility to provide real time solutions where and when you need them.
KNOWLEDGE:If your industrial electrical application demands a specialist team of trained project management, design and engineering professionals, then NHP is the ultimate choice, bringing together over 40 years of electrical industry experience and knowledge.
SCALABILITY:
With all the scale of a large multi-national company, NHP maintain a premium level of customer service and attention to detail no matter how big or small your project. With over 900+ expert staff in over 50+ branch and regional locations, when you deal with NHP you receive all of this combined knowledge and expertise delivered by local people with a local focus, backed by global suppliers.
WE’RE EASY TO DO BUSINESS WITH
NHP ELECTRICAL ENGINEERING PRODUCTS PTY LTD Sales 1300 NHP NHP | nhp.com.au |
3
Quick select guide
DIN Rail Option–According to IEC 61643 /AS/NZS 1768: 2007
Panel Mount Option – According toUL 1449 3rd Edn / AS/NZS 1768: 2007
Fuse/MCB Max. size 125 A
Fuse/MCB Max. size 80 A
Fuse/MCB ≤20 A
• 25 kA Iimp • 100 kA Imax • Pluggable • Remote monitoring
• 40 kA Imax • Remote monitoring • Pluggable
NHP Part No. CPTPSC425400IR
(Also available in Iimp 12.5 kA / Imax 65 kA size)
NHP Part No. CPTPSM440400IR
(Also available in 20 kA sizes)
NHP Part No. CPTDM223020A
Fina
l sub
- cir
cuits
/ In
divi
dual
equ
ipm
ent
Dis
trib
utio
n bo
ard
Mai
n sw
itchb
oard
N
eutr
al
PE
MEN
Individual equipment
• 20 kA Imax EMI/RFI Filter (-75dB) • Remote monitoring • 1 Phase • For circuits < 20 A
MV / 400 V
L>10
met
ers
L>20
met
ers
Fuse/MCB Max. size 80 A
Fuse/MCB Max. size 63 A
Fuse/MCB ≤20 A
• 200 kA Imax • All mode protection • EMI/RFI Filter (-40dB) • Surge counter • Remote monitoring
• 40 kA Imax • All mode protection • EMI/RFI filter (-40dB) • Remote monitoring
• 20 kA Imax • EMI/RFI Filter (-75dB) • Remote monitoring • 1 Phase • For circuits < 20 A
NHP Part No. CPTCPSBLOCKPLUS200
(Also available in 120/160/240 kA sizes)
NHP Part No. CPTCPSNANOPLUS3P40
(Also available in 60 /80/120/160 kA sizes)
NHP Part No. CPTDM223020A
N
eutr
al
PE
MEN
Fina
l sub
- cir
cuits
/ In
divi
dual
equ
ipm
ent
Dis
trib
utio
n bo
ard
Mai
n sw
itchb
oard
Individual equipment
MV / 400 V
L>10
met
ers
L>20
met
ers
4
Surge protectionSurge protection of low-voltage AC power systems
Transient overvoltageTransient overvoltages are surges that can reach tens of kilovolts with duration of the order of microseconds. Despite their short duration, the high energy content can cause serious problems to equipment connected to the line, from premature aging to destruction, causing disruptions to service and financial loss.
The origin of surges can vary from external sources such as lightning and utility grid switching, to internal sources such as the disconnection of motors or other inductive loads. Outdoor and longer lines are the most exposed to these fields, which often receive high levels of induction.
Transient overvoltages do not occur solely in power distribution lines, but are also common in any line formed by metal conductors, such as telephony, communications, measurement and data.
In all these networks, transient overvoltage protection is achieved by installing the protector or line discharger on the vulnerable line, connecting it in parallel between the line and earth. This means that in the event of a transient over-voltage, the protector will discharge excess energy to earth, thus limiting the peak voltage to a value acceptable for the electrical equipment connected.
General operation of a protectorA transient overvoltage protection device acts as a voltage controlled switch and is installed between the active conductors and ground in parallel with the equipment to be protected. When the supply voltage is lower than its activation voltage, the protector acts as a high-impedance element so that no current flows through it. When the supply voltage is higher than the activation voltage, the protector acts as an element with an impedance close to zero, diverting the overvoltage to earth and preventing it from affecting equipment downstream.
Selecting a protectorThe Quick Guide to Surge Protection aims to give an easy to select guide to selection of SPD. The information detailed below provides additional insight into selecting a SPD.
The network typology and the nominal voltage of the electrical supply must be considered when selecting a SPD. Since the SPD acts a voltage controlled switch, the nominal voltage of the network must not exceed the maximum continuous operating voltage (MCOV) of the SPD. If the SPD is connected to a network where the nominal voltage is greater than the MCOV rating of the SPD, the SPD will reach end of life prematurely.
Another point to consider when selecting a SPD, is the voltage protection level, which must be less than the maximum voltage which can be withstood by the equipment to be protected.
Generally, the optimal system of protection is the cascade type, in which successive stages are combined in the performance of high discharge capacity devices and devices with a low voltage protection level.
Depending upon the exposure of the installation to the effects of lightning and transient overvoltages, protection devices with different discharge capacities will be needed. The various local and international standards classify devices into types or categories based on their discharge capacity and voltage protection level.
Installing a surge protection device
SUPPLY
PROTECTOR
LOAD
discharge current
residual voltage of the protection device
voltage surge the equipment is capable of withstanding
Ue
LOAD
Ii
Up
Ii Up Ue
Up < Ue
Installing a surge protection device
SUPPLY
PROTECTOR
LOAD
discharge current
residual voltage of the protection device
voltage surge the equipment is capable of withstanding
Ue
LOAD
Ii
Up
Ii Up Ue
Up < Ue
5
Cascading approach
Protection of low-voltage AC circuits from the effects of transient over-voltages is best achieved in a step by step approach as no single device can totally protect an installation from a very high surge.
The first line of defence should be a service entrance surge diverter connected between each phase of the incoming power line and service entrance ground. These units are designed to withstand high currents and energies in high power surges and will divert much of it to ground. While they can handle the peak they are not necessarily a fine tuned device. The Cirprotec CPS Block Plus (TVSS) surge protection panels or the DIN Rail PSC and CSH range are appropriately located as the first line of defence.
A second line of defence should be a surge suppressor mounted on any distribution panel serving sensitive equipment, such as computers. These can provide excellent attenuation of any residual transient energy that gets past the service entrance surge diverter. The Cirprotec DIN Rail PSM and CPS NANO Plus range is appropriately located at these locations.
Finally, a hard wired filter surge suppressor can be used at the point of connection of sensitive equipment, to completely remove any remaining small transient. This final suppressor also has the benefit of protecting the equipment against transients generated within the facility which can be surprisingly frequent and destructive in aggregate. The fine protection range of Cirprotec surge diverters are suitable for this application.
SPD Back-Up MCB / Fuse
Surge protection devices are connected downstream of a circuit breaker or fuse (F1), in parallel to the rest of the installation. If F1 exceeds the maximum size shown in the table below, it is necessary to install a dedicated circuit breaker or fuse F2. In any case, it is recommended to install a dedicated circuit breaker or fuse for the surge diverter. The main benefit is that maintenance or replacement of the surge unit can be performed easily without the disruption caused through shutdown at the main isolator.
The table below provides minimum size back-up fuses along with maximum size back-up fuses. Ideally the maximum size fuse/breaker would be selected as this ensures the SPD will activate up to its peak capacity to divert the surge. However, selecting the maximum size back-up fuse or MCB may not always be practical. Therefore a minimum back-up overcurrent protection is also listed. It must be noted that by installing a fuse or circuit breaker less than the maximum value, the SPDs may become isolated during a transient event, leaving the installation exposed despite still being able to operate. Therefore, the following recommendations are listed in the table below:
Imax (8/20 µs)
Minimum Back-up Overcurrent Protection
Maximum Back-up Overcurrent protection
MCB Fuse MCB Fuse
PSL Series (IEC Class III)
8 kA 32 A 32 A gL 63 A 63 A gL
PSM Series (IEC Class II)
20 kA 32 A 32 A gL 63 A 63 A gL
40 kA 32 A 32 A gL 80 A 80 A gL
PSC Series(IEC Class I & II)
65 kA 63 A 63 A gL 125 A 125 A gL
100 kA 63 A 63 A gL 125 A 125 A gLCPS Nano Plus Series (UL 1449)
All models 63 A 63 A gL 63 A 63 A gL
CPS Block Plus Series (UL 1449)
All models 63 A 63 A gL 80 A 80 A gL
CSH SeriesSpark Gap
50 kA (10/350 µs) 100 A 100 A gL 200 A 200 A gL
Note: The breaking capacity of the MCB must be higher than the short circuit current of the installation at that point.
If F2 is installed, it must be co-ordinated with the main circuit breaker. This will assure that when the SPD reaches its end of life, F2 will open keeping the entire installation from disconnecting. This is required for installations in which service interruption is critical.
L2L3N
N L2L1 L3
F2
PE
L1F1
6
VPRVoltage protection ratingIndicates the maximum value of residual voltageacross the terminals of the protection deviceduring the application of peak current.
MCOVMaximum continuous operating voltageIndicates the maximum effective voltage thatcan be applied permanently to the terminals ofthe protection device.
InNominal currentPeak current with 8/20 μs waveform whichthe protection device can withstand 15 timeswithout reaching end of life.
ImaxMaximum discharge currentMaximum peak current, per phase, with 8/20 μswaveform which the protection device canwithstand.
Type1:Permanently connected, designed to beinstalled between the service transformerstation and the line (adjacent to theovervoltage device), as well as on the loadside or meters.
Type2:Permanently connected, to the service load side, in distribution panels.
Type3:“Cord-connected” or “direct plug-in”, installed adjacent to the equipment to be protected (about 10 meters from the service panel).
Location Category C:Subject to external transients of atmospheric origin, network switching by the power company and nearby industries, and faults in the distribution system
Location Category B:Subject to externally generated transients as well as switching and transients in the form of a “ring wave” of internal origin. These can be caused by equipment such as motors and production and office equipment.
Location Category A:Subject to a high level of switching transients and “ring waves” caused by commercial, industrial and office equipment, etc.
IEEE C62.41Location
Level of exposure
Type as per UL
1449 Imax
C Highest 1 and 2 240 kA
C Very high 1 and 2 200 kA
B Medium-high 2 160 kA
B Medium 2 100 kA
A Medium-low 2 and 3 80 kA
A Low 2 and 3 40 kA
UL 1449 3rd Ed.:
IEEE C62.41.2-2002:
Classification of protectorsThere are two different protector classifications: according to UL1449 3rd Ed. and according to the C62.41.2-2002 IEEE guide.
Electrical network divertersProtection parameters according to UL
7
Features:• Surge Counter• EMI/RFI Filter (-40dB)• Replaceable modules allows efficient maintenance • All mode protection (L-N, L-G, N-G, L-L)• IAD - Intelligent Aging Display indicates life status of each MOV • MDS - Multi-Discharge system• Suitable for 3 phase WYE networks• IP 55 rating• Remote monitoring via volt free contacts
Max Surge Current(per phase) Phases
Nominal Voltage
EMI/RFI Noise Rejection
Clamping Voltage UL1449 3rd Edition
Protection Modes
Cat. No.
L-N L-G N-G L-L
120 kA 3 230/400 V -40 dB 1000 1000 1000 2000 L-N, L-G, N-G, L-L CPTCPSBLOCKPLUS120
160 kA 3 230/400 V -40 dB 1000 1000 1000 2000 L-N, L-G, N-G, L-L CPTCPSBLOCKPLUS160
200 kA 3 230/400 V -40 dB 1000 1000 1000 2000 L-N, L-G, N-G, L-L CPTCPSBLOCKPLUS200
240 kA 3 230/400 V -40 dB 1000 1000 1000 2000 L-N, L-G, N-G, L-L CPTCPSBLOCKPLUS240
CPS NANO Plus - Compact hardwired surge protection systems
CPTCPSNANOPLUS3P40 EMI/RFI Noise Rejection
Clamping voltageUL1449 3rd Edition
Max.surge current
(per phase) PhasesNominalvoltage L-N L-G N-G L-L
Protection modes Cat. No. 1)
40 kA 3 230/400 V -40 dB 1000 1000 1000 2000 L-N, L-G, N-G, L-L CPTCPSNANOPLUS3P40
60 kA 3 230/400 V -40 dB 1000 1000 1000 2000 L-N, L-G, N-G, L-L CPTCPSNANOPLUS3P60
80 kA 3 230/400 V -40 dB 1000 1000 1000 2000 L-N, L-G, N-G, L-L CPTCPSNANOPLUS3P80
120 kA 3 230/400 V -40 dB 1000 1000 1000 2000 L-N, L-G, N-G, L-L CPTCPSNANOPLUS3P120
160 kA 3 230/400 V -40 dB 1000 1000 1000 2000 L-N, L-G, N-G, L-L CPTCPSNANOPLUS3P160
Features:
• MDS (Multi-Discharge System) technology• Voltage indication LED• Protection status indication LED• Thermal and short-circuit fusing for each MOV (maximum security)• Common & differential protection for each cable
Note: 1) CPSNANO also available without EMI/RFI filter. Contact NHP for details.
• IP 66 rating• Easy installation: wall or flush mounting• Remote monitoring via volt free contacts• EMI/RFI filter (≤40dB)• Suitable for 3 Phase WYE networks
Electrical network divertersCPS BLOCK Plus (TVSS) - Modular Surge Protective Panels
8
Protection parameters according to IEC
UpLevel of protectionMaximum residual voltage between theterminals of the protection device during theapplication of a peak current.
InNominal currentPeak current in 8/20 μs waveform the protectiondevice can withstand 20 times without reachingend of life.
ImaxMaximum discharge currentPeak current with 8/20 μs waveform whichthe protection device can withstand withoutreaching end of life.
UcMaximum continuous operating voltageMaximum effective voltage that can be appliedpermanently to the terminals of the protectiondevice.
IimpImpulse currentPeak current with 10/350 μs waveform whichthe protection device can withstand withoutreaching end of life.
Classification of protectorsProtection devices are classified into typesaccording to discharge capacity:
Type 1:Tested with a 10/350 μs waveform (Class I test), which simulates the current produced by a direct lightning strike.Ability to discharge very high currents to earth, providing a high Up - voltage protection level. Must be accompanied by downstream Type 2 protectors. Designed for use in incoming power supply panels where the risk of lightning strike is high, for example in buildings with an external protection system.
Type 2:Tested with a 8/20 μs waveform (Class II test), which simulates the current produced in the event of a switching or lightning strike on the distribution line or its vicinity.Ability to discharge high currents to earth,providing a medium Up - voltage protectionlevel. Designed for use in distribution panelslocated downstream of Type 1 protectors or in incoming power supply panels in areas with low exposure to lightning strikes.
Type 3:Tested with a combined 1.2/50 μs - 8/20 μswaveform (Class III test), which simulates the current and voltage that can reach the equipment to be protected.Ability to discharge medium currents toearth, providing a low Up - voltage protectionlevel. Always installed downstream of a Type 2 protection designed to protect sensitiveequipment or equipment located more than20 m downstream of the Type 2 device.
The technology can provide protection solutions that
combine different types of protection: Type 1+2 and Type 2+3.
9
Electrical network diverters The Cirprotec range of DIN rail mounted surge diverters are specially designed to provide complete and effective protection against surges, protecting equipment and property connected to the low-voltage network. The Cirprotec DIN rail range consists of the CSH, the pluggable PSC, PSM and PSL series, fine protection surge diverters as well as measure and control line surge diverters.
Features:• Compact size• Status indication (flag or LED) 1)• DIN rail mounting• Thermal disconnection• Remote indication (via volt free contact) 2)• Integrated MOV and/or spark gap technology
CSH seriesThe CSH range of mono bloc protectors (Class 1) includes the CPTCSH150230 and CPTCSH1100N, which are to be installed in areas exposed to a high risk of direct lightning strike.
The model CPTCSH150230 is a lightning current arrestor whilst the CPTCSH1100N is a lightning current arrestor for the neutral line.
No. of phases
No. of poles Iimp Connection Uc Up Cat. No.
1 2 50 kA L-N 275 V <2 kV CPTCSH150230
1 2 100 kA N-PE 255 V <2 kV CPTCSH1100N
Note: 1) Applicable to PSC, PSM, PSL, DM2 and RD2 2) IR models only
10
Electrical network diverters
Notes: 1) Up listed above is between L - N. The Up between N - PE is < 1.5 kV.
No. of phases
No. of poles Iimp Imax Connection In Uc Up Cat. No.
Replacement module
1 1 12.5 kA 65 kA L-N 20 kA 275 V < 1.3 kV CPTPSC1-12-230 IR CPTPSC-12-230 MOD
1 1 25 kA 65 kA N-PE 25 kA 255 V < 1.5 kV CPTPSC1-25N CPTPSC-25N MOD
1 1 25 kA 100 kA L-N 25 kA 275 V < 1.3 kV CPTPSC1-25-230 IR CPTPSC-25-230 MOD
1 1 50 kA 100 kA N-PE 50 kA 255 V < 1.5 kV CPTPSC1-50N CPTPSC-50N MOD
1 1 100 kA 100 kA N-PE 50 kA 255 V < 1.5 kV CPTPSC1-100N CPTPSC-100N MOD
1 2 12.5 kA 65 kA L+N-PE 20 kA 275 V < 1.3 kV CPTPSC2-12-230 IR 1)CPTPSC-12-230 MOD (L-N) CPTPSC-25N MOD (N-PE)
1 2 25 kA 100 kA L+N-PE 25 kA 275 V < 1.3 kV CPTPSC2-25-230 IR 1) CPTPSC-25-230 MOD
3 4 12.5 kA 65 kAL+L+L+ N-PE
20 kA 440 V < 1.3 kV CPTPSC4-12-400 IR 1)CPTPSC-12-230 MOD (L-N) CPTPSC-50N MOD (N-PE)
3 8 25 kA 100 kA L+L+L+N-PE 20 kA 440 V < 1.3 kV CPTPSC4-25-400IR 1) CPTPSC-25-230 MOD
CPTPSC2-12-230 IR
CPTPSM2-40-230 IR
PSC SeriesThe PSC pluggable range consists of Class 1+2 surge protective devices with low Up (protection of downstream equipments) for single-phase and three-phase electrical power networks. These units are ideal for protection of service entrances and distribution panels in areas exposed to lightning activity or externally generated heavy transients.
PSM Series The PSM pluggable range consists of Class 2 surge protective devices designed for protection againsttransient overvoltages in single-phase and three-phase electrical power networks. These units are ideal for protection of distribution and branch panels which should be installed downstream of a Class 1 device.
No. of phases
No. of poles Imax Connection In Uc Up Cat. No.
Replacement module
1 1 20 kA L-N 10 kA 320 V < 1.4 kV CPTPSM1-20-230 IR CPTPSM-20-230 MOD
1 1 20 kA N-PE 10 kA 255 V < 1.5 kV CPTPSM1-20N CPTPSM-20N MOD
1 1 40 kA L-N 20 kA 275 V < 1.3 kV CPTPSM1-40-230 IR CPTPSM-40-230 MOD
1 1 40 kA N-PE 20 kA 265 V < 1.5 kV CPTPSM1-40N CPTPSM-40N MOD
1 2 20 kA L+N-PE 10 kA 320 V < 1.4 kV CPTPSM2-20-230 IR 1)CPTPSM-20-230 MOD (L-N) CPTPSM-20N MOD (N-PE)
1 2 40 kA L+N-PE 20 kA 275 V < 1.3 kV CPTPSM2-40-230 IR 1)CPTPSM-40-230 MOD (L-N) CPTPSM-40N MOD (N-PE)
3 4 20 kAL+L+L+N - PE
10 kA 320 V < 1.4 kV CPTPSM4-20-400 IR 1)CPTPSM-20-230 MOD (L-N) CPTPSM-20N MOD (N-PE)
3 4 40 kAL+L+L+N - PE
20 kA 275 V < 1.3 kV CPTPSM4-40-400 IR 1)CPTPSM-40-230 MOD (L-N) CPTPSM-40N MOD (N-PE)
CPTPSC4-12-400 IR
CPTPSM4-40-400 IR
PSL Series The PSL pluggable range consists of Class 3 surge protective devices designed for fine protection of sensitive equipment in single phase or three phase networks. These units should be installed as close as possible to the equipment you intended to protect and finalise the offering as a cascaded surge protected network, downstream of a Class 2 device.
No. of phases
No. of poles Imax Connection In Uc Up Cat. No.
Replacement module
1 2 8 kA L+N-PE 3 kA 320 V < 1.1 kV CPTPSL2-8-230 IRCPTPSL-8-230 MOD (L-N)CPTPSL-8N MOD (N-PE)
3 4 8 kA L+L+L+N-PE 3 kA 320 V < 1.1 kV CPTPSL4-8-400 IRCPTPSL-8-230 MOD (L-N)CPTPSL-8N MOD (N-PE)CPTPSL4-8 400 IR
CPTPSL2-8 230 IR
11
PSC / PSM / PSL range
The best performance in the market
Remote indicationDry contacts, standard in all
ranges, for remote indicationof protector end of life.
Biconnect connectionTwo types of terminal: forrigid or flexible cable and
for fork type comb busbar.
Cirprotec qualityProduct range producedentirely by Cirprotec, witha thermal disconnectionsystem. Use of the best
materials and components.
Protector lifetimestatus indication
Clear display ofprotection end of life.
Easy to installEasy and quick replacement
of damaged cartridges
New, optimiseddisconnection system
Cirprotec has developed anew, optimised disconnectionsystem for end of life. Complieswith the disconnection tests ofthe new standard for protectors
for photovoltaic applications.
Reversible installationReversible chassis to
allow cable entry fromabove or below.
PolariserSafety system to avoid possiblecartridge replacement errors.
12 11 14
t121114
12
Photovoltaic (PV) divertersPhotovoltaic installations are highly exposed to atmospherical phenomena as well as to the resultingpower surges and induced over-voltages. 80 % of the damages affecting inverter units happen as a resultof overvoltages. Almost 100 % of service interruptions in these plants are associated to atmosphericalphenomena (lightning strikes or discharges). It is therefore very important that both the DC and ACelectrical lines in photovoltaic systems be protected with the appropriate surge protection devices.
DC Protection
PSC3 PluggableThe PSC3 series of surge protective devices comprises of Class 1+2 pluggable protectors for common and differential mode protection at the DC side of photovoltaic power plants with operating voltages of up to 1000 V.These units are ideal for protection of PV applications connected to service entrances and distributionpanels in areas exposed to lightning activity or externally generated heavy transients
CPTPSM3-40-600IR
Iimp Imax In Uoc Up Cat. No.
12.5 kA 65 kA 20 kA 600 V DC < 2.6 kV CPTPSC3-12-600IR
12.5 kA 65 kA 20 kA 1000 V DC < 3.6 kV CPTPSC3-12-1000IR
PSM3 PluggableThe PSM3 series of surge protective devices comprises of Class 2 pluggable protectors for common and differential mode protection at the DC side of photovoltaic power plants with operating voltages of up to 1000 V.These units are ideal for protection of PV applications connected to distribution and branch panels etc.
Imax In Uoc Up Cat. No.
40 kA 20 kA 600 V DC < 2.6 kV CPTPSM3-40-600IR
40 kA 20 kA 1000 V DC < 4.0 kV CPTPSM3-40-1000IR
CPTPSC3-12-600IR
13
Fine protection diverters
DM2 - Surge diverter and EMI filterThe DM2 Class 2+3 surge diverter and filter is used to protect sensitive equipment. The unit has an EMI filter that reduces high-frequency disturbance propagated through the network, which can affect the operation of connected equipment. The DM2 is installed in series with the equipment to be protected and activates with different discharge stages, which are co-ordinated so as to provide a lower residual voltage at the output while at the same time being able to shunt a high discharge current.
DIN24V-3AThe DIN 24 V-3 A Class 3 unit is designed for installations and equipment supplied with 24 V and is installed in series and as close as possible to the equipment being protected.
CPTDIN24V-3A
Imax In InomEMI/RFI
Noise Rejection Uc Up Cat. No.
20 kA (L-G)20 kA (N-G)
10 kA (L-G)10 kA (N-G)
20 A- 74 dB (differential mode) - 82 dB (common mode)
275 V ≤1.2 kV CPTDM2-230-20A
Imax In Inom Uc Up Cat. No.
<10 kA <5 kA 3 A 30 V <0.045 kV CPTDIN24V-3A
Uc In Up Cat. No.
275 V <3 kA <1.2 kV (L-L), <1.5 kV (L-PE) CPTRP2-10-230
140 V <2.5 kA <0.7 kV (L-L), <0.8 kV (L-PE) CPTRP2-10-120
70 V <2.5 kA <0.6 kV (L-L), <0.8 kV (L-PE) CPTRP2-10-60
60 V <1 kA <0.2 kV (L-L), <0.8 kV (L-PE) CPTRP2-10-48
35 V <1 kA <0.2 kV (L-L), <0.8 kV (L-PE) CPTRP2-10-24
14 V <1 kA <0.08 kV (L-L), <0.8 kV (L-PE) CPTRP2-10-12
CPTDM2-230-20A
RP2-10The RP2-10 Class 3 range is designed to protect against transient overvoltages caused mainly by the consequences of atmospheric discharges and network switching. These devices are ideal for fire protection in a 2 pole parallel connected compact unit which are also DC compatible.
CPTRP2-10-230
14
Signal type Maximum comms. voltage Protected wiresMaximum transmission
frequency Protection format Input connector Output connector Product reference
Telephone linesADSL telephony 200 V 2
3MHz DIN Terminal Terminal CPTDIN-ADSL 3MHz Aerial RJ11 Female RJ11 Female CPTMCH-ADSL 3MHz krone Krone terminal block Krone terminal block CPTKPL1 CG 3MHz R &M R&M terminal block R&M terminal block CPTTPL1 CG
PP telephony 10/20 V 2 1MHz DIN Terminal Terminal CPTDIN-PP 1MHz Aerial RJ11 Female RJ11 Female CPTMCH-PP
ISDN telephony 18/56 V 4 2MHz Aerial RJ45 Female RJ45 Female CPTMCH RDSI
Data network Ethernet Cat. 5e 5 V4x2 Cat. 5e (250MHz) 1 pole RJ45 Female RJ45 Female CPTNETPRO 100 BT
(4x2)x18 Cat. 5e (250MHz) 18 pole rack RJ45 Female RJ45 Female CPTNETPRO CG18P (CAT. 6) (4x2)x24 Cat. 5e (250MHz) 24 pole rack RJ45 Female RJ45 Female CPTNETPRO CG-24P (CAT. 5.E)
Ethernet Cat. 6 5 V4x2 Cat. 6 (250MHz) 1 pole RJ45 male UTP cable RJ45 male UTP cable CPTNETPRO CG-1P M
(4x2)x18 Cat. 6 (250MHz) 18 pole rack RJ45 Female RJ45 Female CPTNETPRO CG18P (CAT. 6) (4x2)x24 Cat. 6 (250MHz) 24 pole rack RJ45 Female RJ45 Female CPTNETPRO CG-24P (CAT. 6)
Power over Ethernet, POE 48 V DC / 5 V DC 4x2 Cat. 6 1 pole RJ45 Male (cable) RJ45 Male (cable) CPTNETPRO 1P POE (CAT. 6)
Measurement and control
NET Device 6 V 1 pair 1MHz DIN Terminal Terminal CPTDIN 6V-2C
KNX-Bus 110 V 1 pair 5MHz DIN Terminal Terminal CPTDIN 150V-2C 3MHz DIN Terminal Terminal CPTBNV 110
Modbus 6 V 1 pair 1MHz DIN Terminal Terminal CPTDIN 6V-2C
Profibus PA 24 V1 pair
4MHz DIN Terminal Terminal CPTDIN 24V-2C 3MHz DIN Terminal Terminal CPTBNV 30
2 pairs 2MHz DIN Terminal Terminal CPTDIN 24V-2G2 2+GND 2MHz Sub-D 9 Sub-D Sub-D CPT DB9-PFB/2HS
RS 232
12 V
2 1.2MHz DIN Terminal Terminal CPTDIN 12V-2C 2+GND 3MHz DIN Terminal Terminal CPTDIN 12V-3 4+GND 3MHz DIN Terminal Terminal CPTDIN 12V-5N 7+GND 3MHz DIN Terminal Terminal CPTDIN 12V-8 7+GND 2MHz Sub-D 9 Sub-D Sub-D CPTDB9-12V/9HS
14+GND 2MHz Sub-D 15 Sub-D Sub-D CPTDB15-12V/15HS 23+GND 2MHz Sub-D 25 Sub-D Sub-D CPTDB25-12V/25HS 17+GND 2MHz Sub-D 25 Sub-D Sub-D CPTDB25-V24HS 8+GND 2MHz Sub-D 25 Sub-D Sub-D CPTDB25-232/8HS
24 V
24MHz DIN Terminal Terminal CPTDIN 24V-2C 3MHz DIN Terminal Terminal CPTBNV 30
2+GND 3MHz DIN Terminal Terminal CPTDIN 24V-34 2MHz DIN Terminal Terminal CPTDIN 24V-4G1
4+GND 3MHz DIN Terminal Terminal CPTDIN 24V-5N 7+GND 3MHz DIN Terminal Terminal CPTDIN 24V-8
RS 485 / 42212 V
1 pair 1.2MHz DIN Terminal Terminal CPTDIN 485-2C 1 pair+GND 3MHz DIN Terminal Terminal CPTDIN 485-3 2 pair+GND 3MHz DIN Terminal Terminal CPTDIN 485-5N
24 V1 pair 4MHz DIN Terminal Terminal CPTDIN 24V-2C 2 pairs 2MHz DIN Terminal Terminal CPTDIN 24V-2G2
4 - 20 mA
12 V 1 pair 1.2MHz DIN Terminal Terminal CPTDIN 12V-2C
24 V1 pair
4MHz DIN Terminal Terminal CPTDIN 24V-2C 3MHz DIN Terminal Terminal CPTBNV 30 4MHz DIN Terminal Terminal CPTDIN 24V-2C
2 pairs 2MHz DIN Terminal Terminal CPTDIN 24V-2G2
Binary signals
12 V 2 1.2MHz DIN Terminal Terminal CPTDIN 12V-2C
24 V2
4MHz DIN Terminal Terminal CPTDIN 24V-2C3MHz DIN Terminal Terminal CPTBNV 30
4 2GHz DIN Terminal Terminal CPTDIN 24V-4G1Temperature probe (PTC) 6 V 1 pair 1MHz DIN Terminal Terminal CPTDIN 6V-2C
Radio frequency
Coaxial signal antennas 230 V 1 Coaxial
3GHz Coaxial N Male N Female CPTCT 10 N3GHz Coaxial BNC Male BNC Female CPTCT 10 BNC3GHz Coaxial F Female F Female CPTCT 10 F3GHz Coaxial TV Male TV Female CPTCT 10 TV3GHz Coaxial TNC Male TNC Female CPTCT 10 TNC3GHz Coaxial N Female N Female CPTCT 10 NW3GHz Coaxial UHF Male UHF Female CPTCT10 UHF
CCTV 24 V 1 Coaxial 3GHz Coaxial BNC Male BNC Female CPTCT 05 CCTVWimax 135 V 1 coaxial 5.8 GHz Aerial N Male N Female CPTCT 30 N
CPTKPL1CG
CPTNETPRO100BT
CPTBNV30
CPTDIN12V-2C
CPTDIN24V-2G2
CPTDIN485-3
CPTCT-10F
i - Indent item
Fine protection diverters Telephone lines | Data Network | Measurement and Control | RF
15
Signal type Maximum comms. voltage Protected wiresMaximum transmission
frequency Protection format Input connector Output connector Product reference
Telephone linesADSL telephony 200 V 2
3MHz DIN Terminal Terminal CPTDIN-ADSL 3MHz Aerial RJ11 Female RJ11 Female CPTMCH-ADSL 3MHz krone Krone terminal block Krone terminal block CPTKPL1 CG 3MHz R &M R&M terminal block R&M terminal block CPTTPL1 CG
PP telephony 10/20 V 2 1MHz DIN Terminal Terminal CPTDIN-PP 1MHz Aerial RJ11 Female RJ11 Female CPTMCH-PP
ISDN telephony 18/56 V 4 2MHz Aerial RJ45 Female RJ45 Female CPTMCH RDSI
Data network Ethernet Cat. 5e 5 V4x2 Cat. 5e (250MHz) 1 pole RJ45 Female RJ45 Female CPTNETPRO 100 BT
(4x2)x18 Cat. 5e (250MHz) 18 pole rack RJ45 Female RJ45 Female CPTNETPRO CG18P (CAT. 6) (4x2)x24 Cat. 5e (250MHz) 24 pole rack RJ45 Female RJ45 Female CPTNETPRO CG-24P (CAT. 5.E)
Ethernet Cat. 6 5 V4x2 Cat. 6 (250MHz) 1 pole RJ45 male UTP cable RJ45 male UTP cable CPTNETPRO CG-1P M
(4x2)x18 Cat. 6 (250MHz) 18 pole rack RJ45 Female RJ45 Female CPTNETPRO CG18P (CAT. 6) (4x2)x24 Cat. 6 (250MHz) 24 pole rack RJ45 Female RJ45 Female CPTNETPRO CG-24P (CAT. 6)
Power over Ethernet, POE 48 V DC / 5 V DC 4x2 Cat. 6 1 pole RJ45 Male (cable) RJ45 Male (cable) CPTNETPRO 1P POE (CAT. 6)
Measurement and control
NET Device 6 V 1 pair 1MHz DIN Terminal Terminal CPTDIN 6V-2C
KNX-Bus 110 V 1 pair 5MHz DIN Terminal Terminal CPTDIN 150V-2C 3MHz DIN Terminal Terminal CPTBNV 110
Modbus 6 V 1 pair 1MHz DIN Terminal Terminal CPTDIN 6V-2C
Profibus PA 24 V1 pair
4MHz DIN Terminal Terminal CPTDIN 24V-2C 3MHz DIN Terminal Terminal CPTBNV 30
2 pairs 2MHz DIN Terminal Terminal CPTDIN 24V-2G2 2+GND 2MHz Sub-D 9 Sub-D Sub-D CPT DB9-PFB/2HS
RS 232
12 V
2 1.2MHz DIN Terminal Terminal CPTDIN 12V-2C 2+GND 3MHz DIN Terminal Terminal CPTDIN 12V-3 4+GND 3MHz DIN Terminal Terminal CPTDIN 12V-5N 7+GND 3MHz DIN Terminal Terminal CPTDIN 12V-8 7+GND 2MHz Sub-D 9 Sub-D Sub-D CPTDB9-12V/9HS
14+GND 2MHz Sub-D 15 Sub-D Sub-D CPTDB15-12V/15HS 23+GND 2MHz Sub-D 25 Sub-D Sub-D CPTDB25-12V/25HS 17+GND 2MHz Sub-D 25 Sub-D Sub-D CPTDB25-V24HS 8+GND 2MHz Sub-D 25 Sub-D Sub-D CPTDB25-232/8HS
24 V
24MHz DIN Terminal Terminal CPTDIN 24V-2C 3MHz DIN Terminal Terminal CPTBNV 30
2+GND 3MHz DIN Terminal Terminal CPTDIN 24V-34 2MHz DIN Terminal Terminal CPTDIN 24V-4G1
4+GND 3MHz DIN Terminal Terminal CPTDIN 24V-5N 7+GND 3MHz DIN Terminal Terminal CPTDIN 24V-8
RS 485 / 42212 V
1 pair 1.2MHz DIN Terminal Terminal CPTDIN 485-2C 1 pair+GND 3MHz DIN Terminal Terminal CPTDIN 485-3 2 pair+GND 3MHz DIN Terminal Terminal CPTDIN 485-5N
24 V1 pair 4MHz DIN Terminal Terminal CPTDIN 24V-2C 2 pairs 2MHz DIN Terminal Terminal CPTDIN 24V-2G2
4 - 20 mA
12 V 1 pair 1.2MHz DIN Terminal Terminal CPTDIN 12V-2C
24 V1 pair
4MHz DIN Terminal Terminal CPTDIN 24V-2C 3MHz DIN Terminal Terminal CPTBNV 30 4MHz DIN Terminal Terminal CPTDIN 24V-2C
2 pairs 2MHz DIN Terminal Terminal CPTDIN 24V-2G2
Binary signals
12 V 2 1.2MHz DIN Terminal Terminal CPTDIN 12V-2C
24 V2
4MHz DIN Terminal Terminal CPTDIN 24V-2C3MHz DIN Terminal Terminal CPTBNV 30
4 2GHz DIN Terminal Terminal CPTDIN 24V-4G1Temperature probe (PTC) 6 V 1 pair 1MHz DIN Terminal Terminal CPTDIN 6V-2C
Radio frequency
Coaxial signal antennas 230 V 1 Coaxial
3GHz Coaxial N Male N Female CPTCT 10 N3GHz Coaxial BNC Male BNC Female CPTCT 10 BNC3GHz Coaxial F Female F Female CPTCT 10 F3GHz Coaxial TV Male TV Female CPTCT 10 TV3GHz Coaxial TNC Male TNC Female CPTCT 10 TNC3GHz Coaxial N Female N Female CPTCT 10 NW3GHz Coaxial UHF Male UHF Female CPTCT10 UHF
CCTV 24 V 1 Coaxial 3GHz Coaxial BNC Male BNC Female CPTCT 05 CCTVWimax 135 V 1 coaxial 5.8 GHz Aerial N Male N Female CPTCT 30 N
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i - Indent item
16
IEC
UL
Protected equipment or installationPoint of installation
Lightning discharge protection
Surge protection, overvoltage protection
Transient overvoltage protection
Permanent (TOV) overvoltage protection
Signal line overvoltage protector (RF)
Communal aerial IRS* (TV, radio)
Rooftop telecom installation
CPT-CT10F
IEC
ULIEC
UL
IEC
UL
Signal line overvoltage protector (telephone)
Telephone installation - cable pairs
Indoor building entrance, telephone applications
CPT-KPLISG
IEC
UL
IEC
UL
IEC
UL
STEP 2
Antenna Amplifier
Application - Residential / Commercial Building
* 1 per each descending coaxial cable
17
Type 2 Surge Protector
Lift, lighting, car park, alarms, entrance doors etc.
Distribution board
IEC
UL
IEC
UL
IEC
UL
Type 2 & 3 Surge protector and filterIEC
UL
Type 2 Surge protector
Home appliances and electronics
Home electrical sevice panel
CPTPSM2-20-230 IR
IEC
ULIEC
UL
IEC
UL
Type 1 & 2 Surge Protector
Service entrance panel and downstream installation
Service entrance/energy meter
IEC
UL
IEC
UL
IEC
UL
STEP 2
STEP 3
STEP 2
Sensitive equipment
ie television, PLC etc
Sub-branch panel/end circuit
CPTDM2-230-20A
IEC
UL
IEC
UL
CPTPSM4-40-400 IR
CPTPSC4-25-400 IR
18
Application - Photovoltaic Power Plant
Signal line overvoltage protector (measure and control)
CPTDB9-12V-9HS
Type1+2 DC lightning arrester + surge protector
Inverter, communication devices
Transformation centre
Type 2 DC surge protector
Inverter, communication devices
Transformation centre
CPTPSM3-40-1000 IR
Type 1+2 AC lightning arrester + surge protection
Inverter, communication devices
Transformation centre
CPTPSC4-12-400 IR
Type 2 AC surge protector
Inverter, communication devices
Transformation centre
CPTPSM4-40-400 IR
MODEM
Signal line overvoltage protector (telephone)
Modem, energy meter-telephone interface
Transformation centre
CPTDIN-ADSL
NTU TELEPHONE
Network termination unit
AC side
DC side
T1+2
IEC
UL
Protected equipment or installationPoint of installation
Lightning discharge protection
Surge protection, overvoltage protection
Transient overvoltage protection
Permanent (TOV) overvoltage protection
T2
T1+2
T2
IEC
UL
IEC
UL
IEC
UL
IEC
ULIEC
UL
IEC
UL
IEC
ULIEC
UL
IEC
UL
IEC
ULIEC
UL
IEC
UL
IEC
ULIEC
UL
IEC
UL
IEC
ULIEC
UL
IEC
UL
PV performance monitoring and communication devices
Transformation centre
CPTPSC3-12-1000 IR
ACEnergy meter
Inverter DC
Installation with Lighting
Protection System (LPS)
Installation without
Lightning Protection
System (LPS)
Installation without
Lightning Protection
System (LPS)
Installation with Lightning
Protection System (LPS)
19
Application - Water Treatment Plant
Type 3 transient overvoltage protector w/EMI filter
Analogue field instrumentation equipment: flowmeter, oximeter, pHmeter
Outdoor water instrumentation panel
CPTDM2-230-20A
Signal line overvoltage protector (measurement & control)
Analogue field instrumentation equipment: flowmeter, oximeter, pHmeter
Outdoor water instrumentation panel
CPTDIN-24V-2C
IEC
UL
STEP 1 CATEGORY C
Signal line overvoltage protector (communication)
PLC-communication interface
MCC* Panel
CPTDB9-12V-9HS
Type 1+2 Surge protection
TVSS Surge protector 240 kA/phase
IEC
UL
IEC
UL
STEP 3 CATEGORY A
IEC
UL
Signal line overvoltage protector (measure & control)
PLC-input/output signals
MCC * Panel
CPTDIN-24V-2G2
or
CPTBNV-30
IEC
UL
IEC
ULIEC
UL
IEC
UL
IEC
UL
IEC
UL
IEC
UL
IEC
UL
IEC
UL IEC
UL
IEC
UL
IEC
ULIEC
UL
IEC
UL
Type 3 transient overvoltage protector w/EMI filter
PLC-power supply
MCC * Panel
CPTDM2-230-20A
IEC
UL
IEC
ULIEC
UL
IEC
UL
IEC
UL
Type 2 Surge protection
TVSS Surge protector 40 kA/phase
Frequency inverters and pumps
MCC * Panel
IEC
UL
IEC
UL IEC
ULIEC
UL
CPTPSM4-40-400 IR
or
CPTCPSNANOPLUS3P40
IEC
UL
Protected equipment or installationPoint of installation
Lightning discharge protection
Surge protection, overvoltage protection
Transient overvoltage protection
Permanent (TOV) overvoltage protection
STEP 3 CATEGORY A
STEP 2 CATEGORY B
Service entrance panel and downstream installation
Service entrance
CPTPSC4-25-400 IR
or
CPTCPSBLOCKPLUS240
IEC
UL
NHP Electrical Engineering Products Pty LtdA.B.N. 84 004 304 812
NCIRC 2/14 © Copyright NHP 2014
AUSTRALIAnhp.com.au
SALES 1300 NHP NHP
FAX 1300 NHP FAX
VICTORIAMelbourne 43-67 River Street Richmond VIC 3121 Tel +61 3 9429 2999
Laverton 104-106 William Angliss Drive Laverton North VIC 3026 Tel +61 3 9368 2901
Albury / Wodonga 847 Ramsden Drive Albury NSW 2640 Tel +61 2 6049 0600 Fax +61 3 6025 0592
Dandenong Unit 1/80 Monash Drive Dandenong South VIC 3175 Tel +61 3 8773 6400 Fax 1300 647 329
TASMANIAHobart 29B Lampton Ave Derwent Park TAS 7009 Tel +61 3 6228 9575 Fax +61 3 6228 9757
Launceston Unit 3 13-17 Merino Street Kings Meadows TAS 7249 Tel +61 3 6345 2600 Fax +61 3 6344 6324
NEW SOUTH WALESSydney 30-34 Day Street North Silverwater NSW 2128 Tel +61 2 9748 3444
Newcastle 575 Maitland Road Mayfield West NSW 2304 Tel +61 2 4960 2220 Fax +61 2 4960 2203
Wollongong Unit 3 1 Resolution Drive Unanderra NSW 2526 Tel 1300 647 647 Fax 1300 647 329
ACTCanberra Unit 1 187 Gladstone Street Fyshwick ACT 2609 Tel +61 2 6280 9888 Fax +61 2 6280 9588
WESTERN AUSTRALIAPerth 38 Belmont Ave Rivervale WA 6103 Tel +61 8 9277 1777
NORTHERN TERRITORYDarwin 3 Steele Street Winnellie NT 0820 Tel +61 8 8947 2666 Fax +61 8 8947 2049
QUEENSLANDBrisbane 16 Riverview Place Murarrie QLD 4172 Tel +61 7 3909 4999
Townsville 5 Leyland Street Garbutt QLD 4814 Tel +61 7 4779 0700 Fax +61 7 4775 1457
Rockhampton 1 Lawson Street Parkhurst QLD 4702 Tel +61 7 4927 2277 Fax +61 7 4922 2947
Toowoomba Cnr Carroll Street and Struan Court QLD 4350 Tel +61 7 4634 4799 Fax +61 7 4633 1796
Cairns Unit 2 1 Bramp Close Portsmith QLD 4870 Tel +61 7 4035 6888 Fax +61 7 4035 6999
SOUTH AUSTRALIAAdelaide 36-38 Croydon Road Keswick SA 5035 Tel +61 8 8297 9055
NEW ZEALANDnhp-nz.com
SALES 0800 NHP NHP
FAX 0800 FAX NHP
PO Box 62-009 Sylvia Park Auckland 1644 New Zealand
Auckland 118a Carbine Road Mt Wellington 1060
Hamilton 78 Rostrevor Street Hamilton 3204
Napier 126 Taradale Road Onekawa 4110
New Plymouth 2 Dean Place Waiwhakaiho 4312
Wellington Unit B4, 59 Marsden Street Melling Lower Hutt 5010
Christchurch 27 Iversen Terrace Waltham 8011
Dunedin 30 Fox StreetSouth Dunedin 9012
For more information, scan to download the NHP eCatalogues App o�ering exclusive video content, catalogues and literature!