CIF Communication Interface
Communication for PC based Automation
One configurationfor all fieldbussesThe SyCon system configurator allowsthe uniform configuration of the commu-nication relationship between fieldbusSlave devices and the Master.The configuration of the communicationrelationship to the individual Slave devicesand the respective fieldbus Master arestored permanently down in the configu-ration memory of the CIF card.
Fieldbus systems made easyWith a fieldbus card as a fieldbus Master,one always has the current process imageof all configured Slave devices.With a CIF card for fieldbus Slave communi-cation, the Dual Port memory of the cardserves as a process image which can beaccessed from both sides at the same time.In both variants the user program neednot concern itself with the actual fieldbuscommunication as this task is automaticallyundertaken by the CIF card, thanks to itsown communication processor.
ISA
-
8/10/2019 CIF-e.pdf
3/4
All card formatsWhether Soft programmable control system, CNC
control, Industry terminal, decentralized I/O moduleor intelligent drive, every application based on aPC standard can be equipped with a CIF card for industrial communication.
DriversThe universal CIF Device Driver andthe function library DRV-TKIT presentthe basis for the execution of thefieldbus integration on the applicationlevel independently of the selectedhardware platform. An integrationonce developed can then be usedwith every available fieldbus system.Drivers for many Soft PLCs are avail-able.
The CIF OPC-Server is available for everyfieldbus standard and all Windows-basedoperating systems.There are finished drivers available for manyvisualizing systems and with these the CIFcards can be accessed directly.
Diagnostic InterfaceSerial RS 232 Interface for configurationand online diagnostic.
LED status displaysThe operational condition of the CIF cardand the communication activities on thefieldbus interface are displayed.
I PCMCIA Compact PCI PC/104 PC/104+ PMC-Modul
-
8/10/2019 CIF-e.pdf
4/4
CIF
Technical Data
Product overview
Fieldbus ISA Slave Master AS-Interface CIF 30 -ASMCANopen CIF 30 -COS -COMControlNet CIF 30 -CNS -CNMDeviceNet CIF 30 -DNS -DNMInterBus CIF 30 -IBS -IBMModbus Plus CIF 30-MBPPROFIBUS CIF 30 -DPS -PB
Fieldbus PCI Slave Master AS-Interface CIF 50 -ASMCANopen CIF 50 -COS -COMCC-Link CIF 50 -CCSControlNet CIF 50 -CNS -CNMDeviceNet CIF 50 -DNS -DNMEthernet CIF 50-ENInterBus CIF 50 -IBS -IBMModbus Plus CIF 50-MBPPROFIBUS CIF 50 -DPS -PBSERCOS CIF 50-SCMSERCOS CIF 50-SCEB passiv
Fieldbus PCMCIA Slave Master CANopen CIF 60 -COS -COMDeviceNet CIF 60 -DNS -DNMInterBus CIF 60 -IBM
PROFIBUS CIF 60 -DPS -PBSERCOS CIF 60-SCEB passiv
Fieldbus Compact PCI Slave Master CANopen CIF 80 -COS -COMDeviceNet CIF 80 -DNS -DNMPROFIBUS CIF 80 -DPS -PB
Fieldbus PC/104 Slave Master AS-Interface CIF 104 -ASMCANopen CIF 104 -COS -COMCC-Link CIF 104 -CCSControlNet CIF 104 -CNS -CNMDeviceNet CIF 104 -DNS -DNMInterBus CIF 104 -IBS -IBMEthernet CIF 104-ENModbus Plus CIF 104-MBPPROFIBUS CIF 104 -DPS -PB
SERCOS CIF 104-SCEB passiv
Fieldbus PC/104+ Slave Master CANopen PC/104+ -COMDeviceNet PC/104+ -DNS -DNMPROFIBUS PC/104+ -PB
Fieldbus Mezzanine Card Slave Master CANopen PMC -COS -COMDeviceNet PMC -DNS -DNMPROFIBUS PMC -DPS -PB
Technical Data
AS-Interface Master 2 channels62 Slaves248 Inputs/186 Outputs
CANopen Slave Master 127 CANopen nodes
510 Byte I/O data 7 KByte I/O data
32 Rx-/32 Tx-PDOs unlimited PDOsMin.Boot up Min.Boot upCOB ID Distribution COB ID Distributiondefault/via SDO default/via SDOEmergency Message Emergency MessageLife Guarding, Heartbeat Node, Life Guarding, HeartbeatEvent trigger Event trigger Remote request Cyclic, Acyclic
Remote requestCiA DS-401, -402, -406
CC-Link Slavemax. 4 stations each with64 Bit I/O data8 Words I/O dataPolling
ControlNet Slave Master
480 Words I/O da ta 7 KByte I/O dataCIP, Peer-to-Peer CIP, Peer-to-Peer Network Access Port Network Access Port
DeviceNet Slave Master 63 Slaves
510 Byte I/O data 7 KByte I/O dataExplicit, Polling Explicit, Polling, Bit-strobe,Bit-strobe,Cyclic, Cyclic, Change of StateChange of State
Ethernet 7 KByte E/A-DatenBOOTP, DHCP, FTP, SMTP, SNMP, TCP/IP, UDP,Open Modbus, Ethernet/IP
InterBus Slave Master 128 Slaves
20 Words I/O data 1024 Byte I/O dataPCP channel PCP channel
InterBus-LoopGeneration 4
PROFIBUS-DP Slave Master 125 Slaves
368 Byte I/O data 7 KByte I/O dataDPV1-Extension DPV1-Extension
class 2 servicesMPI-functions
SERCOS Passiv Master SERCON 816 8 drive
Diagnostic interfaceRS232C, non isolated
Operating voltages/ temperature5 V/max. 500 mA 650 mA
12 V/max. 50 mA CIF 30/CIF 505 V 5%/650 mA CIF 603,3 V + 5% / 500 mA CIF 805 V 5%/650 mA CIF 1043,3 V 5 %/400 mA CIF 104P, PMC5 V 5 %/250 mA CIF xx-SCEB5 V 5%/400 mA CIF xx-SCM0 C 55 C
Headquarter DeutschlandHilscher Ges. frSystemautomation mbHRheinstr. 15D-65795 HattersheimTel. +49 (0) 61909907-0Fax +49 (0) 61909907-50E-Mail: [email protected]: www.hilscher.com
SubsidiaryFranceHilscher FranceFR-69500 BronTel. +33 (0) 472379840Fax +33 (0) 478268327E-Mail: [email protected] web: www.hilscher.com
ItalyHilscher Italia S.r.LIT 20090 MI, VimodroneTel. +39 (0) 225007068Fax +39 (0) 225029973E-Mail: [email protected]: www.hilscher.com
SchweizHilscher Swiss GmbHCH 4500 SolothurnTel. +41(0) 326236633Fax +41(0) 326236632E-Mail: [email protected]: www.hilscher.com
USAHilscher North America Inc.US 60555 WarrenvilleTel. +1 (0) 6308368677Fax +1 (0) 6308368010E-Mail: [email protected]: www.hilscher.com
DistributorsAustraliaFieldbus Specialistswww.fieldbus.com.au
AustriaElektronik-Systeme Lauer GmbHwww.elektronik-systeme.psoft.at
BelgiumTelerex N.V.S.A.www.telerex-europe.com
BrazilSoft Brasil Automacao Ltda.www.softbrasil.com.br
ChinaShanghai CIT Controlwww. citect.com-cn
FinlandNovotek Finland Oywww.dosesoft.fi
JapanEuro-Far-East Co. Ltd.www.euro-fareast.co.jp
KoreaCREVIS Co.,LTDwww.CREVIS.co.kr
NetherlandsTelerex Nederland B.V.www.telerex-europe.com
Norway AD Elektronik ASwww.ade.no
PortugalMVA Electrotecniawww.mva.pt
RussiaProSoft Ltd.www.prosoft.ru
SingaporeVector Info Techwww.vectorinfotech.com
South AfricaInnomaticwww.innomatic.co.za
SpainSistel Control SLwww.sistelcontrol.com
SwedenNovotek Sverige ABwww.novotek.se
TschechienZPA-Industry a.s.www.zpaindustry.cz
UKMiles Industrial Electronics Ltdwww.milesie.co.uk
Special DevelopmentsDo you need a special card with a special protocol?We are in a position to meet your special needs. Challenge us ...