FACULTY OF BIOSCIENCE ENGINEERING CENTRE FOR ENVIRONMENTAL SCIENCE AND TECHNOLOGY Academic year 2015-2016 CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS EMISSION IN RWANDA AND BIOFILTRATION OF ACETONE, DIMETHYL SULFIDE AND HEXANE Juvenal MUKURARINDA Promoter: Prof. dr. ir. Herman VAN LANGENHOVE Tutors: Dr. ir. Christophe WALGRAEVE Ir. Joren BRUNEEL Master’s dissertation submitted in partial fulfillment of the requirements for the degree of Master of Science in ENVIRONMENTAL SANITATION

Upload: others

Post on 17-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

FACULTY OF BIOSCIENCE ENGINEERING

CENTRE FOR ENVIRONMENTAL SCIENCE AND TECHNOLOGY

Academic year 2015-2016

CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

COMPOUNDS EMISSION IN RWANDA AND BIOFILTRATION

OF ACETONE, DIMETHYL SULFIDE AND HEXANE

Juvenal MUKURARINDA

Promoter: Prof. dr. ir. Herman VAN LANGENHOVE

Tutors: Dr. ir. Christophe WALGRAEVE

Ir. Joren BRUNEEL

Master’s dissertation submitted in partial fulfillment of the requirements for the degree of

Master of Science in ENVIRONMENTAL SANITATION

Page 2: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

i

COPYRIGHT

The author and promoter give permission to use this thesis for consultation and to copy parts of it

for personal use. Every other use is subject to the laws of copyright; more specifically the source

must be extensively specified when using results from this dissertation.

Gent, June 2016.

Juvenal MUKURARINDA (author)

Ir. Joren BRUNEEL (tutor)

Dr. ir. Christophe WALGRAEVE (tutor)

Prof. dr. ir. Herman VAN LANGENHOVE (promoter)

Page 3: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

ii

ACKNOWLEDGEMENTS

First of all, I want to say thank you to God Almighty for his faithfulness, mercy, provision,

protection and support during my entire study period.

I would never have been able to finish my thesis without guidance from my tutors and professor.

My deepest gratitude goes to my promoter Prof. dr. ir. Herman Van LANGENHOVE for allowing

me to do research at the EnVOC lab. I am also particularly grateful to him for his scholastic

guidance, innovative suggestions, and supervision throughout the period of research work.

I gratefully thank my tutors, Dr. ir. Christophe WALGRAEVE and Ir. Joren BRUNEEL for their helpful

attitude, constant encouragement, providing information constructive comments and great

endurance throughout the research and manuscript writing. They consistently allowed this paper

to be my own work, but steered me in the right direction whenever they thought I needed it.

I also gratefully acknowledge the valuable comments and suggestions from

Prof. dr. ir. Kristof Demeestere during the EnVOC presentation seminars.

I wish to extend my gratitude to all members of the EnVOC family especially Lore and Patrick for

their kind assistance during the research time.

My sincere gratitude and cordial respect to Prof. dr.ir. Peter Goethals to have allowed me to join

the challenging but wonderful program (Master of Science in Environmental Sanitation). My

sincere thanks to the coordinators of the program: Sylvie, Veerle for their kind cooperation,

valuable advice and continuous encouragement during the entire study period.

I would like to like to thank the Flemish Interuniversity Council i.e. Vlaams Interuniversitaire Raad

(VLIR-OUS) for offering me a scholarship to pursue higher education at Ghent University, Belgium

as well as for their blessed aim of transferring knowledge towards developing countries such as

Rwanda.

Finally, I must express my very profound gratitude to my parents, sisters and brother for providing

me with unfailing support and continuous encouragement throughout my years of study.

Page 4: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

iii

ABSTRACT

Rwanda’s economic transformation is based on the service delivery, mining sector and industrial

activities. Technologies to handle the emissions in industries from production processes especially

VOC are yet to be established. In addition to that, no studies have been conducted before to

check the status of emissions made in different local manufacturing industries in Rwanda. VOC

are organic compounds which have adverse effects on human health as well as the

environment when exposed to high concentrations for long time.

This study was divided into two parts: In the first part, samples by means of Tenax TA sorbent

tubes were collected indoor and outdoor in three different industries, Sulfo Rwanda industry,

AMEKI color and Inyange industries. Samples were analyzed by TD-GC-MS and a total new data

of 45 VOCs concentrations levels were monitored to both indoor and outdoor environment of

the three local manufacturing industries. In Sulfo, soap production unit, the TVOCs indoor and

outdoor were 3.38 103 and 3.51 103 μg.m-3 respectively. Still at Sulfo, cosmetic production unit,

the TVOCs was 0.13 103 μg.m-3 for indoor and 0.06 103 μg.m-3 for outdoor. In AMEKI color, the

indoor and outdoor was 39.2 103 and 0.02 103 μg.m-3 respectively. At Inyange, the TVOCs

encountered were 0.45 103 μg.m-3 indoor and 0.02 103 μg.m-3 outdoor. The second part of the

study investigated the performance of a biofilter contaminated by three compounds with

different physical chemical properties, acetone, DMS and hexane. By means of SIFT-MS, VOC

concentrations were measured at different position along the BF and perform dynamic

partitioning coefficient of BF packing materials. The performance assessment of the biofilter was

done by comparing inlet concentrations (IL), elimination capacity (EC) and removal efficiency

(RE). The maximum RE of the mixed target total VOC was 74 % to IL of 22.4 ± 4.80 mg C.m-3.min-1

and EC of 16.6 ± 4.07 mg C.m-3.min-1 at an EBRT of 57 s. The highest maximum RE for individual

contaminants was 99.9 % for acetone at an IL of 20.9 mg.m-3.min-1 and 20.9 mg.m-3.min-1 EC. The

maximum RE of DMS was 74 % at IL of 34.9 mg.m-3.min-1 and 25.72 mg.m-3.min-1 EC. The maximum

RE for hexane was 47 % at IL of 67.33 mg.m-3.min-1 and 31.68 mg.m-3.min-1 EC.

Based on this performance, biofiltration can be seen as an urgent technology for the treatment

of the target VOC in manufacturing and production industries where technology for VOC

treatment is yet to be implemented.

Keywords: VOC, thermal desorption, gas chromatography, mass spectroscopy, biofiltration,

selected ion flow tubes mass spectroscopy (SIFT-MS), Ion Chromatography.

Page 5: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

iv

TABLE OF CONTENTS

COPYRIGHT ................................................................................................................................................... i

ACKNOWLEDGEMENTS................................................................................................................................ ii

ABSTRACT .................................................................................................................................................... iii

GENERAL INTRODUCTION ........................................................................................................................... 1

PROBLEM STATEMENT ................................................................................................................................... 1

CHAPTER 1 LITERATURE REVIEW ................................................................................................................... 2

1.1 Volatile organic compounds ..................................................................................................................... 2

1.2 Sources of Volatile organic compounds ................................................................................................ 2

1.2.1 Natural sources ....................................................................................................................................... 3

1.2.2 Anthropogenic sources ........................................................................................................................ 3

1.3 Hazards of VOCs ............................................................................................................................................ 4

1.3.1 Human health effect ............................................................................................................................ 4

1.3.2 Tropospheric photochemical ozone formation ............................................................................ 5

1.3.3 Stratospheric ozone depletion ........................................................................................................... 6

1.3.4 Global Greenhouse effect .................................................................................................................. 6

1.4 Air pollution control technologies for VOCs ........................................................................................... 7

1.4.1 Non-biological technology for VOCs ............................................................................................... 9

1.4.2 Biological treatment of VOCS ............................................................................................................ 9

1.4.2.1 Biotrickling filters ............................................................................................................................ 10

1.4.2.2 Bioscrubber .................................................................................................................................... 11

1.4.2.3 Biofilter ............................................................................................................................................. 12

1.4.3 The biodegradation of hydrophobic compounds ..................................................................... 15

1.4.4 Parameters used to check the performance of the biological systems .............................. 16

1.5 Scope and objectives ................................................................................................................................ 16

CHAPTER 2 MATERIALS AND METHODS .................................................................................................... 18

PART I: ANALYSIS OF INDUSTRIAL VOC CONCENTRATIONS IN RWANDA ............................................ 18

2.1 Tenax TA tubes ............................................................................................................................................. 18

2.2 Conditioning ................................................................................................................................................. 18

2.2.1 Loading with internal standards ...................................................................................................... 19

2.2.1.1 Chemicals ...................................................................................................................................... 19

2.2.1.2 Preparation of the closed two-phase system ...................................................................... 19

2.2.1.3 Calculation of the headspace concentration .................................................................... 20

Page 6: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

v

2.2.1.4 Loading ........................................................................................................................................... 20

2.2.2 Pump Calibration ................................................................................................................................. 20

2.3 Sampling Campaigns ................................................................................................................................. 20

2.3.1 Description of the sampling locations............................................................................................ 22

2.3.1.1 Sulfo Rwanda Industries .............................................................................................................. 22

2.3.1.2 AMEKI Color ................................................................................................................................... 23

2.3.1.3 Inyange Industries ........................................................................................................................ 23

2.4 Analysis of Tenax TA sampling tubes ...................................................................................................... 24

2.4.1 TD-GC-MS ............................................................................................................................................... 24

2.4.2 Calibration of the TD-GC-MS ............................................................................................................ 25

2.5 Quantification .............................................................................................................................................. 26

2.5.1 Calculation of the analyte concentration ................................................................................... 26

PART II: ABATEMENT TECHNOLOGY ......................................................................................................... 28

2.6 BIOFILTRATION ............................................................................................................................................... 28

2.6.1 Physical chemical properties of the representative VOC compounds ............................... 28

2.6.2 Biofiltration process .............................................................................................................................. 28

2.6.2.1 Biofiltration design ........................................................................................................................ 28

2.6.2.2 Biofiltration setup .......................................................................................................................... 28

2.6.3 Characterization of the packing materials .................................................................................. 30

2.6.3.1 Bulk Density .................................................................................................................................... 31

2.6.3.2 Moisture content .......................................................................................................................... 31

2.6.3.3 Water holding capacity ............................................................................................................. 31

2.6.3.4 Porosity ............................................................................................................................................ 31

2.6.4 Environmental conditions of the filter bed .................................................................................... 34

2.6.4.1 Temperature .................................................................................................................................. 34

2.6.4.2 pH ..................................................................................................................................................... 34

2.6.4.3 Nutrients .......................................................................................................................................... 34

2.6.4.3 Pressure drop ................................................................................................................................. 34

2.6.5. Analytical instrumentation ............................................................................................................... 35

2.6.5.1 Analysis with SIFT-MS .................................................................................................................... 35

2.6.5.2 Analysis with Ion chromatography .......................................................................................... 35

Page 7: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

vi

CHAPTER 3 RESULTS AND DISCUSSION ..................................................................................................... 36

PART I: INDUSTRIAL VOC ANALYSIS IN RWANDA .................................................................................... 36

3.1 Results ............................................................................................................................................................. 36

3.2 Discussion ....................................................................................................................................................... 41

3.2.1 General discussion ............................................................................................................................... 41

3.2.1 Indoor to outdoor concentrations of the sampling sites .......................................................... 44

Part II: BIOFILTRATION OF VOC ................................................................................................................ 46

3.3 Results and discussion ................................................................................................................................ 46

3.3.1 Partition coefficient of the pollutants to the packing materials ............................................. 46

3.3.2 Biological oxidation of pollutants. ................................................................................................... 48

3.3.3 Bioreactor bed ..................................................................................................................................... 49

3.3.4 The Carbon dioxide (CO2) and Elimination capacity (EC) ...................................................... 51

3.3.5 The effect of pH on the removal of target VOC ......................................................................... 52

3.3.6 Sulfate measurement ......................................................................................................................... 53

3.3.7 Effect of Silicon on the removal of hexane .................................................................................. 54

3.3.8 Inhibitory effect for hexane degradation ..................................................................................... 54

CHAPTER 4 CONCLUSION AND RECOMMENDATION ............................................................................. 56

4.1 CONCLUSION ............................................................................................................................................... 56

4.2 RECOMMENDATION.................................................................................................................................... 57

REFERENCES ................................................................................................................................................ 58

APPENDIX I ................................................................................................................................................. 69

APPENDIX II ................................................................................................................................................ 72

A. Breakthrough curves for dry silicon foam ............................................................................................... 72

B. Breakthrough curves for dry wood chips ................................................................................................ 72

C. Breakthrough curves for dry compost .................................................................................................... 73

D. Breakthrough curve of compost at normal and dry condition. ...................................................... 73

Page 8: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

vii

LIST OF FIGURES

Figure 1: Industrial sector VOC emissions in EU-27 ....................................................................................... 4

Figure 2: A tree diagram of the VOC emissions abatement technology (Khan & Ghoshal, 2000). . 8

Figure 3: Application limit of flow rate vs VOC concentrations of different air pollution

technologies control. ..................................................................................................................... 8

Figure 4 : Biotrickling filter setup . .................................................................................................................. 11

Figure 5: Bioscrubber setup. ......................................................................................................................... 12

Figure 6: A typical setup of biofilter. ............................................................................................................ 12

Figure 7: Conditioning oven ......................................................................................................................... 19

Figure 8: Tol-d8 structure. ................................................................................................................................ 19

Figure 9 : Sampling locations on the map of Kigali city........................................................................... 21

Figure 10: Soap production unit. Figure 11: Cosmetics production unit. .......................... 22

Figure 12: Paint production. .......................................................................................................................... 23

Figure 13: Juice and milk production unit. ................................................................................................. 24

Figure 14 : The TD-GC-MS with (1) the TD (2) the transfer line from GC to MS, (3) GC and (4) MS. 24

Figure 15: Schematic diagram of the biofiltration setup. it. .................................................................... 29

Figure 16: Actual setup of the biofilter ........................................................................................................ 30

Figure 17: Packing materials used in biofiltration process. ...................................................................... 30

Figure 18: The peak injection experiment of acetone, DMS and hexane. .......................................... 32

Figure 19: The peak injection experiment using methane gas. ............................................................. 32

Figure 20: Breakthrough curve of the pollutant to the packing material and blank. ....................... 33

Figure 21: Pressure drop in the filter bed. .................................................................................................... 34

Figure 22: The total indoor and outdoor concentrations of four sampling sites. ................................ 41

Figure 23: The indoor total VOC concentrations of chemical groups in four sampling sites. .......... 42

Figure 24: The outdoor total VOC concentrations of chemical groups in four sampling sites. ....... 42

Figure 25: Indoor target groups’ abundances in four sampled sites. ................................................... 43

Figure 26: Outdoor target groups’ abundance in four sampled sites. ................................................. 43

Figure 27: Partitioning coefficient of acetone, DMS and Hexane ......................................................... 47

Figure 28: The normalized start up concentrations of acetone, DMS and hexane at EBRT of 57 s.49

Figure 29: The Total inlet concentrations ( ) and total removal efficiency ( ) of the three

pollutants at EBRT of 57 s. ............................................................................................................ 50

Figure 30: EC in function of IL of acetone, DMS and hexane at an EBRT of 57 s. ............................... 51

Figure 31: Produced CO2 in function of total EC at an EBRT of 57 s. ..................................................... 52

Figure 32: RE in function of pH of acetone, DMS and hexane at an EBRT of 57 s. ............................. 53

Figure 34: The EC in function of IL for hexane in mixture and hexane only at EBRT of 57 s. .............. 55

Page 9: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

viii

LIST OF TABLES

Table 1: Related health effects to exposure of high VOC concentrations. .......................................... 4

Table 2: Classification of vapor phase biotechnology systems. ............................................................ 10

Table 3: Performance parameters used in biological treatment systems. .......................................... 16

Table 4: The overview information of the VOC sampling campaign collected at three local

industries in Rwanda. ....................................................................................................................... 22

Table 5: Physical chemical properties of acetone, dimethyl sulfide and hexane. ............................ 28

Table 6: Calculated physical chemical properties of the packing materials. .................................... 32

Table 7: The precursor and products ion used to measure concentrations in SIFT-MS. .................... 35

Table 8: Indoor VOC concentrations (μg.m-3) measured at four sampling sites, Kigali, Rwanda. . 37

Table 9: Outdoor VOC concentrations (μg.m-3) measured at four sampling sites, Kigali, Rwanda.

.................................................................................................................................................................... 39

Table 10: Indoor to Outdoor ratio concentrations of the four sampling sites. .................................... 44

Table 11: Calculated partitioning coefficients of the dry packing material ....................................... 47

Table 12: Performance parameters of the biofilter. ................................................................................ 49

Page 10: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

ix

LIST OF ABBREVIATION

AMEKI

Atelier des Meubles de Kigali

BF

Biofilter

Cin Inlet Concentration

Cout

Outlet concentration

CTS Closed two phase system

DMS

Dimethyl Sulfide

EBRT Empty Bed Residence Time

EC Elimination Capacity

EPA Environment Program Agency

GC Gas Chromatography

GWP Global Warming Potential

I/O Inlet to Outlet ratio

IL Inlet Load

IS Internal Standards

MINICOFIN

Ministry of Finance and Economic Planning, Rwanda

NIST National Institute of Standard and Technology

NOx Nitrogen Oxides

Q Flow

RF Response Factor

RSRF Relative Sample Response Factor

SIFT-MS Selected Ion Flow Tubes Mass Spectroscopy

TD Thermal Desorption

TVOCs Total Volatile Organic Compounds

V Volume

VOC Volatile Organic Compounds

Page 11: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

1

GENERAL INTRODUCTION

PROBLEM STATEMENT

Air is an important free available commodity which defines life on earth but due to mostly

human activities the quality of air is changing and this reflect negative effects to human health

as well on environment.

The atmospheric emissions trends in developing countries are increasing mainly because of their

rapid economic transformation especially in urban places. In the last decade, emissions in

developed countries are reported to have decreased but some are still in higher concentrations

than the air quality standards for the protection of human health (Guerreiro et al., 2014). The

World Health Organizations (WHO) report that about seven million death globally attributed by

both indoor and outdoor air quality (WHO, 2014).

Atmospheric emissions are composed of (in) organic compounds and particulate matter.

Volatile organic compounds (VOCs) are part of organic compounds. They are harmful

pollutants with the ability to form the undesired photochemical tropospheric ozone smog and

potentially carcinogenic and mutagenic (Mohammed et al., 2013). Also VOCS participate in

destruction of stratospheric ozone which protects us from UV radiation (Mohammed et al., 2013).

Rwanda is an African developing country striving to transform its economy on average to 11.5 %

of Gross Domestic Products (GDP) growth by 2018 (MINECOFIN 2013). To attain that goal,

industries are increasing day to day in the country but know-how of handling emissions from

industrial activities is still lacking and there are no available air pollution control technologies. To

the best of our knowledge, so far in Rwanda no studies have been conducted to check the air

quality status in local manufacturing industries.

Therefore, to start bridging the gap, it is fortunate to characterize VOCs emitted from local

manufacturing industries in Rwanda and evaluate the performance of the cost effective

abatement technology which can be used to handle emission emitted during production

processes.

Page 12: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

2

CHAPTER 1 LITERATURE REVIEW

1.1 Volatile organic compounds

Air is an essential component of life on earth. Therefore, air pollution is seen as a serious threat to

human being and the environment. Volatile organic compounds also commonly shorten as

VOCs, are organic compounds usually distinguished based on two groups definition; effect

definition and definition based on physical chemical properties (Demeestere et al., 2007).

Firstly, effect definition, US EPA define VOC as any compound containing at least one atom of

carbon, excluding carbon monoxide, carbon dioxide, carbonic acid, metallic carbides or

carbonates, and ammonium carbonates which participate in atmospheric photochemical

reactions (EPA, 2016). Secondly, based on physical and chemical properties, Solvent Emission

Directive (SED) defines VOC as any organic compound having at 20 °C a vapor pressure of

0.01 kPa (Directive 1999/13/EC).

Methane is often viewed separately due to non-absolute reactivity in the troposphere and

different concentrations range observed in different part of the atmosphere

(Demeestere et al. 2007). Therefore, it is imperative to take care of VOCs due to damage they

cause to both human health and as well as environment. They contribute to major

environmental problems to mention, global warming, stratospheric ozone depletion and

photochemical smog (Do et al., 2015). In presence of light, VOC react with nitrogen oxides to

form tropospheric ozone which in high concentrations cause human health problem

(Do et al., 2015). Many other VOCs like styrene and benzene are said to be responsible for

numerous adverse health effects, mainly respiratory, heart disorders and carcinogenic

(Stoji et al., 2015).

1.2 Sources of Volatile organic compounds

Sources of VOCs are divided into anthropogenic and natural sources. Anthropogenic sources

are the man-made VOCs while natural are emitted naturally mostly from vegetation. Often a

term biogenic is used to describe natural emissions of non-methane hydrocarbons (Evuti, 2013).

Emissions distribution depends on the industrial activities, climate and vegetation and varies

region to region (Evuti, 2013).

Globally, the biogenic VOCs, 1150 106 ton.yr-1 (Goldstein & Galbally, 2007), emissions in remote

areas are almost 10 times higher than the anthropogenic VOCs, 142.106 ton.yr-1 (Müller, 1992),

per carbon per year in the forms of VOCs. The inverse happen in urban places where

anthropogenic surpasses biogenic emissions concentrations (Burrows et al., 2007).

Page 13: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

3

1.2.1 Natural sources

VOCs are naturally emitted from vegetation (Guenther et al., 2006). They account isoprenoids

(terpenes and monoterpenes) as well as alkanes, alkenes, carbonyls, alcohols, esters, ethers and

acids (Guenther et al., 2006) .

The concentrations of the emitted compounds reveal isoprenoids to be most prominent

compounds followed by alcohol and carbonyl compounds (Kesselmeier and Staudt, 1999).

The oxidation of the biogenic VOCs produce products with low volatility which participate in the

formation of Secondary Organic Aerosols (SOAs) (Kavouras et al., 1998; O’Dowd et al., 2002;

Kanakidou et al., 2005; Jimenez et al., 2009).

SOAs have an important impact on air quality and climate (Fiore et al., 2012; Scott et al., 2014).

To climate, SOA absorb and scatter solar radiation and they indirectly affect the cloud

condensation (Gouw, 2009).

Methane is not accounted in the oxidation process although it is produced naturally from

wetlands, rice field, livestock, landfills, biomass burning, forests, termites and oceans; it’s total

emissions is in between 145 to 260 106 ton.yr-1 (EPA, 2016).

1.2.2 Anthropogenic sources

Human made emissions encounter indoor and outdoor environment and they vary from various

sources (Bari et al., 2015). Indoor VOC concentrations are generally found in higher levels than

the ambient outdoor levels (Fellin et al., 1994; Spengler, 1995; Zhu et al., 2005; Heroux et al., 2008;

Stocco et al., 2008 ). Indoor VOCs are most emitted from building materials (e.g, floor and wall

coverings, carpet, insulation, paint), combustion processes (e.g, smoking, cooking, home

heating), consumer products (e.g, cleaners, solvents, air fresheners, and mothballs), attached

garages, dry-cleaned clothing, municipal tap water, or personal care products

(Wallace et al., 1987; Batterman et al., 2007; Stocco et al., 2008; wheeler et al.,2013;

Ye et al., 2014).

According to European Environment Agency, the main sectors involved in high VOC emissions

for the EU-27 are solvent and product use (41 %), the road and no road transportation

(18%), and commercial, institutional and household associated emissions (14 %)

(European environment Agency, 2010). Still in the EU-27 at the industry level, the most occurred

VOC sources are in; (1) energy (41 %), (2) chemical industry (22 %) and (3) coating and surface

treatment activities (18 %) (European Pollutant Release and Transfer Register, 2016) (Figure 1).

Ambient outdoor sources combine natural (e.g, vegetation and fires) and anthropogenic

sources (e.g, evaporation processes associated with industry and transportation, or paints and

solvents use) (Watson et al.,2001; Liu et al., 2008). In urban atmosphere, motor vehicles exhaust

Page 14: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

4

and evaporative emissions are reported to have higher VOCs emissions concentrations than

other sources (Cetin et al.,2003; Lin et al., 2004).

Figure 1: Industrial sector VOC emissions in EU-27 (Adapted from European Pollutant

Release and Transfer Register, 2016).

1.3 Hazards of VOCs

1.3.1 Human health effect

The exposure to higher permissible limit of VOCs concentrations lead to acute or chronic health

effects (e.g, exposure to ceiling concentration for an 8 hours shift than 500 ppm of toluene

causes headache and dizziness (Jiang et al., 2005) (Table 1). But biochemical pathways and

physiological functions of most VOCs to human health are still uncertain (Rudnicka et al., 2014).

Table 1: Related health effects to exposure of high VOC concentrations.

Chemical compound Health effect

Benzene Carcinogenic

Ethers Producing peroxides, affecting the reproductive

system

Xylene Eye and respiratory tract irritation, narcotic effect,

nervous system depression and death

Chloroform Affect central nervous system causing depression,

dizziness, liver and kidney damages, skin infection

Acetone and Acetaldehyde Respiratory and eye irritation

Phenol Offensive odor and toxicity

Epoxides Toxic, carcinogenic, explosive

N-containing compounds

(Amines)

Bad Odor, carcinogenic (affecting urinary bladder)

Source: Viswanathan et al (2007).

41%

18%

8% 1%

22%

6% 1% 3%

Energy Sector

Coating & Surface treatment

activitiesProduction and processing of metals

Mineral Industry

Chemical Industry

Paper and wood production

Waste and Wastewater

management

Page 15: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

5

1.3.2 Tropospheric photochemical ozone formation

Troposphere is the region of the Earth’s atmosphere where people reside and in which most

chemical compounds are emitted as a result of human activities (Atkinson 2000). Nitrogen

oxides (NOx= NO + NO2), VOCs and sulfur compounds lead the chemical and physical

transformation which results in the formation of tropospheric ozone globally (Logan, 1994), acid

deposition (Schwartz, 1989). The production of ozone in troposphere relies on the photolysis of

NO2 (Equation 1) and the subsequent association of the photoproducts O(3P) with O2 via

(Equation 2) through the molecular reaction with the third body (M being used to present any

third body co reactants, i.e N2) (Monks et al. 2015).

The mechanism reaction of tropospheric ozone formation is a complex branched chain reaction

between the VOCs and NOx in the presence of light (Evuti 2013). Equation 3 to 9 depicts the

mechanism reaction of tropospheric reaction. Ozone is first used as source of hydroxyl radicals

(OH) (Monks et al., 2015) through

O3 + ℎ𝑣 → O2 + O(1D) (Eq.3)

O(1D) + H2O → 2OH∙ (Eq.4)

Where O(1D) is the electronic excited state atomic oxygen formed through photolysis at

wavelengths <320 nm (Monks et al. 2015) . VOC, indicated here as R-H, molecules react with OH

to generate water vapor (H2O) and radical (R.) (Equation 5).

2OH∙ + R − H → R. + H2O (Eq.5)

The radical R. reacts directly with oxygen molecule yields peroxy radicals (RO2), which in turn

react with nitrogen monoxide (NO) to form nitrogen dioxide (NO2).

Under the influence of light, NO2 is decomposed into NO and oxygen atom (O). The reaction is

completed by oxygen atom and oxygen molecule to generate ozone (O3) (Monks et al., 2015).

NO2 + ℎ𝑣 → NO + O(3P) (Eq.1)

O(3P) + O2 + M → O3 + M (Eq.2)

R∙ + O2 → RO2 (Eq.6)

RO2 + NO → RO + NO2 (Eq.7)

NO2 + ℎ𝑣 → NO + O(3P) (Eq.8)

O(3P) + O2 + M → O3 + M (Eq.9)

Page 16: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

6

The tropospheric O3 produced from hydrocarbon reactions as well as other sources is reportedly

to harm plants by reducing their growth due to limitation of carbon dioxide in stomata of

vegetation (Felzer et al., 2007).

1.3.3 Stratospheric ozone depletion

Stratospheric ozone layer is known to protect lower part of the earth’s atmosphere from high

frequency Ultraviolet (UV) light (Albritton, 1998). The ozone layer is reduced as a result of

imbalance between the formation and loss of ozone, where destruction is higher than

production (T et al., 2011).

Chlorine and Bromine released from man-made compounds such as chlorofluorocarbons

(CFCs) (example of CFC is dichlorodifluorocarbon [CCl2F2]) prone highly to the destruction of

stratospheric ozone (Angell et al., 2005). CFCs have long life time in the atmosphere (10 to 120

years) (Angell et al., 2005). As a matter of fact, CFCs are transported to the stratosphere where

they are eventually broken down by UV rays forming free chlorine (Equation 10) which reduce

ozone to oxygen molecule (equation 11 to 13).

CCl2F2 + ℎ𝑣 → Cl∙ + CF2Cl. (Eq. 10)

Cl. + O3 → ClO. + O2 (Eq. 11)

ClO. + O → Cl. + O2 (Eq. 12)

O3 + 0 → 2O2 (Eq. 13)

1.3.4 Global Greenhouse effect

Earth has the capacity to balance the absorption and emission of solar radiations (Evuti, 2013). It

absorbs the energy in the form of ultraviolet, visible light and infrared and emits the infrared to

outer space(Mohammed et al., 2012). Any process which interfere with this balance result in the

phenomenon of global warming also termed as climate change or greenhouse effect

(AEA group, 2007).

The Infrared (IR) absorption of atmospheric trace gases, water vapor and carbon dioxide

(Derwent, 1995; Mohammed et al., 2012) disturbs the radiative balance. Therefore, earth’s

surface and the atmosphere react to the disturbance by warming to restore the radiative

balance. This process is termed as radiative forcing and the warming is the greenhouse effect.

Halogenated compounds are also claimed to be powerful greenhouse gases and deplete

stratospheric ozone, they are ozone depleting substances (ODSs) especially compounds which

have chlorine and bromine attached on, hence, causing global warming (Myhre et al. 2013)

Page 17: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

7

The effect of the compounds to cause global warming compared to carbon dioxide is

expressed in term of Global Warming Potentials (GWPs)(Evuti, 2013) (Table 2). The GWP is defined

as a ratio of the radiative forcing from a given mass emission of the trace gas compared to that

from the same mass emission of carbon dioxide, integrated over a given time horizon

(Mohammed et al., 2012).

Table 2: Global warming potential (GWP) of some VOCs in a 100-year time horizon.

Source: AEA group (2007).

1.4 Air pollution control technologies for VOCs

Many technologies have been introduced for VOC emission control. The available techniques

are basically classified into two different categories: (i) process and equipment modification and

(ii) add on control technique (Khan & Ghoshal, 2000) (Figure 2). In the first category, control of

VOC emissions are made by modifying the process equipment, raw material, and / or change

the process (Khan & Ghoshal, 2000).

On the other hand the latter category, require an additional control method to regulate the

VOC emissions. It has two subgroups dubbed destruction and recovery of VOCs

(Khan & Ghoshal, 2000; Delhoménie & Heitz, 2005).

VOC GWP VOC GWP

Carbon dioxide 1 Dimethylether 1

Bromomethane 5 propylene 4.9

Propane 6.3 ethylene 6.8

Butane 7 1,1- Difluoroethane 122

Ethane 8.4 Difluoromethane 670

Dichloromethane 10 1,1,1,3,3,-Pentafluorobutane 782

Chloromethane 16 1,1,1,3,3-Pentafluoropropane 1020

Dichlorotrifluoroethane 76 1,1,1,2-Tetrafluoethane 1410

Dichloropentafluoropropane 120 1,1,1,2,3,4,4,5,5,5-Decafluoropentane 1610

1,1,1-Trichloroethane 144 1,1,1,2,3,3,3 Heptafluoropropane 3140

Dichlorotetrafluoroethane 599 Pentanfluoromethane 3450

Dichlorodifluoroethane 713 1,1,1-Trifluoroethane 4400

Chlorodifluoromethane 1780 1,1,1,3,3,3- Hexafluoropropane 9500

Chlorodifluoroethane 2270 Trifluoromethane 14310

Page 18: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

8

*RFR: Reverse Flow Reactor

Figure 2: A tree diagram of the VOC emissions abatement technology (Khan & Ghoshal, 2000).

The adaptation or choice of technology lies on the operating conditions (flow rate,

temperature, humidity and VOC concentrations) and the pollutants physico-chemical

characteristics (solubility, vapor pressure, biodegradability level and inflammability)

(Crocker & Schnelle, 1998). An illustration is given in Figure 3, of the application limit for flow rate

in function of VOC concentrations of destruction and recovery technologies.

Figure 3: Application limit of flow rate vs VOC concentrations of different air pollution

technologies control (Delhoménie and Heitz 2005).

VOC removal technique

Process and equipment

modification

Condensation Oxidation

Add on control techniques

Destruction Recovery

Absorption Adsorption Biofiltration Membrane

separation

Thermal

oxidatio

n

RFR*

8

Catalytic

oxidation

Activated carbon based adsorption Zeolite based adsorption

Page 19: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

9

Biofiltration is the only biological VOC treatment technology found in recovery technologies. The

remaining ones found in recovery and all destruction control techniques are non-biological

treatment technologies.

1.4.1 Non-biological technology for VOCs

As indicated in Figure 3, the non- biological technologies are physical chemical technologies

generally applied to reduce off-gas with high VOC emission concentrations. The lower VOC

concentrations in the flue gases the higher energy input will be required to get rid of the VOC

especially in the oxidation processes (incinerations)(Khan and Ghoshal, 2000). In terms of cost,

physical chemical treatment technologies for VOCs emission involve higher cost than biological

treatments (Font and Artola 2011).

1.4.2 Biological treatment of VOCS

The biological treatment technology (biotechnology) for VOCs emissions was introduced first by

the European countries (Germany followed by The Netherlands), in 1960 (Leson & Winer, 1991;

Cloirec et al, 2005). The fundamental purpose of that biological treatment technology was to

handle odor and VOC emission at the industrial scale (Álvarez-hornos et al., 2011).

In 2003, the European IPPC reported that vapor-phase biotechnologies, including biofilters,

biotrickling filters and bioscrubbers, have proven to be more environmental friendly and chosen

as best available technologies for the reduction of the VOC emissions in chemical sector

(European commission, 2003).

Hence, biological gas treatment (biotechnologies) are seen as potential alternative to the

conventional physico-chemical processes for removal of VOCs with high flow rate emission

streams with relative low VOC concentrations; conditions observed more particular in painting,

coating and printing processes (Álvarez-hornos et al., 2011).

Biotechnologies or biological VOC treatment technologies rely on the capacity of

microorganisms of using their metabolisms to translate the organic pollutants to less harmful

compounds. Since the pollutants are in gas phase, they have to be transferred in aqueous

phase to be ready and used by microorganism (Álvarez-hornos et al. 2004).

The overall degradation process of the biofiltration is presented in Equation 14

( Álvarez-hornos et al., 2011; Font & Artola, 2011).

Organic pollutant + O2 CO2 + H2O + heat + biomass + other byproduct (Eq. 14)

microbes

Page 20: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

10

The main types of biological treatment of VOC emissions include biofilters, biotrickling filters and

bioscrubbers (Delhoménie and Heitz 2005). The basic idea for the removal of VOCs mechanism

for these three biological technologies is similar but there notable differences with regards to the

aqueous phase and microorganism growth (Álvarez-hornos et al., 2011) (table 2).

Table 2: Classification of vapor phase biotechnology systems.

Biotechnology system Microorganism growth Aqueous phase

Biofiltration Attached growth Stationary

Biotrickling filter Attached growth Flowing

Bioscrubber Suspended growth Flowing

Source: Álvarez-hornos et al (2011).

1.4.2.1 Biotrickling filters

In biotrickling filters, biodegrdation happen when the gas is first transferred to the biofilm which

grow to the packing materials. The packing materials are made from chemical inert materials

such as plastic rings (Waweru et al,. 2000), resins, ceramics, celite, polyurethane foam

(Yamashima and Kitagawa, 1998), and no nutrients are available in such materials for

microorganism to grow. Nutrients are continuously supplied from the top to bottom in

countercurrent with the flue gas, the leachate is collected at the bottom and recycled back up

(Berenjian et al., 2012)( Figure 4). This feeding process facilitates control of biological operating

parameters like nutrients and pH (Muñoz et al., 2015). Soluble VOC are reported to be highly

removed by biotrickling flters (Berenjian et al., 2012).

The major bottleneck of this system is the clogging of excess biomass in the filter bed and

research has developed three major solutions, mechanical, chemical and biological

(Delhoménie and Heitz 2005). Mechanical by bed stirring (Wübker et al., 1997;

Laurenzis et al., 1998) or bed backwashing with water which allows drainage of the excess

accumulated biomass (Smith et al., 1996).

Chemical treatment to breakdown the chemical bindings between biomass and bed particle

by using disinfecting reagents (Diks et al.,1994; Schönduve et al., 1996; Cox and Deshusses, 1999;

Armon et al., 2000; Chen and Stewart, 2000). Biological use biomass predators such as protozoa

(Cox and Deshusses, 1997). Amongst all these solutions mechanical treatment using water for

backwashing is claimed to be most efficient and at least friendly to the ecosystem

(Cai et al., 2004).

Page 21: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

11

Figure 4 : Biotrickling filter setup (Delhoménie and Heitz, 2005).

1.4.2.2 Bioscrubber

The bioscrubber contains two reactors, the absorption tower and bioreactor. In the absorption

tower, the gas is absorbed or diffused into aqueous solution via the countercurrent gas-liquid

flow through the inert packing materials. Packing material within the absorption tower provides

a better surface transfer between VOC and aqueous phase (Kellner and Flauger, 1998)

(Figure 5). The washed off or clean gas flow to the top and the contaminated liquid is pumped

in the bioreactor (Berenjian, Chan, and Malmiri 2012). The bioreactor is inoculated with

degrading constrains in aqueous phase and contains nutrients essential for their growth and

maintenance

(Delhoménie and Heitz 2005). The major limitation of bioscrubbing system is that they are applied

to only soluble contaminants with low Henry’s constant (<0.01) and low concentrations

(<5 mg.m-3)(Berenjian, Chan, and Malmiri 2012).

Continuous trickling Treated air

Polluted air

Bed made

from inert

materials,

inoculated

Nutrient solution

Waste solutions possible recycling

Page 22: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

12

Figure 5: Bioscrubber setup (Delhoménie and Heitz, 2005).

1.4.2.3 Biofilter

This is the most basic biological treatment process that uses organic packing materials in which

culture of microorganisms are developed to degrade pollutants into less harmful compounds.

The contaminated air pass through a biofilter packed with organic carrier materials where

biofilm are fixed (Figure 6). Before the inlet gas stream enters the filter bed, it is pre-humidified to

avoid clogging in filter bed (Waweru et al., 2000). Biodegradation happen when the pollutant is

first transferred from gas to liquid phase. In the liquid phase, the pollutant is either absorbed in

water or adsorbed on the packing material. The unavailable pollutants for biofilm diffuse through

the filter bed.

Figure 6: A typical setup of biofilter (Delhoménie and Heitz 2005).

Aqueous solution Clean air

Bioreactor

Waste solutions containing pollutants

Polluted air

Activated sludge, suspended in

nutrient solution

Absorption

column

Treated air

Nutrient solution

Occasional irrigation

Waste solutions possible recycling Polluted air

Bed packed

with organic

materials

Page 23: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

13

The successfulness of microorganisms to degrade pollutants depends on a good follow up of

physical, chemical and biological parameters of the biological system:

(I) Filter bed, is an important part of the biological treatment process because they support the

growth of microorganism communities responsible for pollutants degradation and increase the

contact between the gas and biofilm (Iranpour et al., 2005; Kennes et al., 2009).

A good packing material should have a high specific area favorable for microbial activity, good

water retention to avoid dehydration, high porosity to provide a homogeneous gas distribution

entirely into bed, availability of intrinsic for nutrients and diverse microflora

(Delhoménie & Heitz, 2005; Berenjian et al., 2012).

The most used organic packing media are compost, peat, soil, and at smaller scale woodchips

and bark(Easter et al., 2005; Delhoménie & Heitz, 2005; Gabriel et al., 2007). Studies made on

woodchips or bark found that these packing materials are less satisfactory as compared to peat

and compost because of their low pH buffering capacity, low specific area and nutrient

availability (Smet et al., 1996a; Smet et al., 1999; Hong & Park, 2004).

(II) Moisture content is a crucial parameter for effective filter bed as microorganisms need water

to carry their metabolic activity (Shareefdeen et al., 2005). Less bed moisture content lead to

dehydration and gas channeling which affect particularly the microflora

(Delhoménie and Heitz 2005). On the contrary too much water in the filter bed cause flooding

which leads to compaction and anaerobic conditions (Delhoménie and Heitz 2005). The

moisture content of the overall carrier materials must have a value between 40 and 60 (w/w)

(Ottengraf 1986; Waweru et al., 2000).

(III) Temperature, microbial activity also depends on the biofilter operating temperature. The

microbial growth in biological systems works at a temperature between 10 and 40oC

(Cloirec et al., 2005). Most of microorganisms grow in the biofilter are mesophilic

(Kennes & Thalasso, 1998) at a temperature ranging between 20 and 40 oC. And this

temperature ranges define the optimum temperature in biofilters (Delhoménie and Heitz 2005).

(IV) pH, to support the microbial growth a pH range from 5 to 9 is normally used and the stability

of this parameter in the biofilter increase the microbial activity (Cloirec et al. 2005). The optimum

pH is around neutrality, pH≈7 (Delhoménie and Heitz 2005). Compounds containing heteroatoms

(sulfur, chlorine and nitrogen) are oxidized to acid by-products which in turn lower the pH of the

biofilter (Devinny and Hodge, 1995; Christen et al., 2002). The effect of pH on biofiltration

efficiency depends on types of microorganisms (Clark et al., 2004). Fungi has the ability to grow

Page 24: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

14

at both neutral as well as acidic medium conditions and they are metabolically active at pH

approximately between 2 and 7 (Delhoménie and Heitz 2005). On the other hand, bacteria are

very sensitive to pH, they are less tolerant to pH below 7 (Kumar et al., 2011). Two methods used

by authors to maintain pH to neutrality are either to irrigate the biofilter by nutrients solution

which have buffer capacity or insert the buffer materials in biofilters

(Delhoménie and Heitz 2005). Nevertheless, the ideal pH of the biofilter medium depends on the

pollutant being treated and the characteristics of the microbial ecosystem (Kumar et al., 2011) .

(V)Nutrient requirement, aerobic microorganisms’ performance in biofilter depends on the

availability of nutrients. The most elements needed for the growth of the biomass are nitrogen,

phosphorous, potassium, sulfur and trace elements in additional to oxygen and carbon

(Álvarez-hornos et al., 2011). For the long term performance of the biofilter an additional of

nutrients is required (Yang et al., 2002). Due to the importance of nitrogen towards biomass

growth, an additional of nitrogen to the biofitler media is reported to enhance the performance

of the biofilter (Morales et al., 1998).

(VI) Bed porosity, this is an essential parameter which maintains even air flow rate and decrease

the pressure drop across biofilter (Álvarez-hornos et al., 2011). The filter bed which used only

compost as packing material report to be 44.4 % for dry compost and 39.6 % for wet compost

(Douglas & Devinny, 1997). To increase the porosity and decrease degree of compaction in the

bed filter, a mixture of packing materials are used (Bohn, 1992).

(VII) Inlet pollutant concentration, obviously biofilter perform best for treating pollutant which are

in concentration less than 1000 ppm. High inlet VOC concentration in the biofilter lead to

inhibition of microbial activity (Álvarez-hornos et al., 2011). Also, high inlet concentrations lead to

insufficient oxygen availability in biofilter (Ottengraf, 1987). Studies have found that 30 ppm of

toluene had 99% removal efficiency but when doubled its concentration, the removal get down

to 82% removal efficiency (Álvarez-hornos et al., 2011).

(VIII) Microorganisms and acclimation time, the natural organic packing material used in bed

media parent microorganism in biofiltration. Microorganism such bacteria and fungi are used for

the degradation of VOCs (Kumar et al., 2011). The degradation of the pollutant depend on the

nature of the filtering materials and the biodegradability level of VOC to be treated

(Kumar et al., 2011). A single type of microorganism is enough to degrade certain pollutants and

for certain group of pollutants or even a culture of microorganism is used (Nanda et al., 2012).

Page 25: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

15

Compost has been reported to use bacteria belonging to a group of Proteobacteria,

Actinobacteria, Bacteroidetes and Firmicutes (Chung, 2007).

An acclimation, time required obtaining stable high removal efficiency over a long time, for

microorganism to handle new substrate environment may take 10 days to 10 weeks

(Ralebitso et al., 2012). Introduction of inoculum to the bed media can shorten the lag phase

(Álvarez-hornos et al., 2011). A typical biofilter usually contains 106-1010 cfu of bacteria and

actinomycetes per gram of bed and fungi in the range of 103-106 cfu per gram of bed

(Ottengraf, 1987). Degrading species in a biofilter are normally between 1 and 15 % of the total

microbial population (Pedersen et al., 1997; Delhomenie et al., 2001).

(IX) Empty bed residence time (EBRT), both air flow rate and EBRT are important parameters with

reasonable impact on the biodegradation performance of the biofilter (Elmrini et al., 2004).

Increasing EBRT will produce high removal efficiency. EBRT can be relied on to increase the

biofiltration performance and should be greater the time needed for diffusion processes for low

operating flow rate (Álvarez-hornos et al., 2011).

1.4.3 The biodegradation of hydrophobic compounds

Hydrophobic compounds have high Henry’s constant as compared to hydrophilic compounds.

That said, they are less soluble in water than hydrophilic compounds a factor which make them

often hard to reach the biofilm layer in biofilter thus providing low removal efficiency.

The composition of the filter materials is a critical parameter for effective biofilter toward the

removal efficiency of the hydrophobic and less soluble compounds. Studies conducted on

biofiltration of hydrophobic compounds proposed that improved adsorbing materials such as

granular activated carbon (GAC) may have characteristics that may promote higher

elimination capacity particularly for compounds with low solubility that emitted in variable loads

(Tonekaboni, 1998). Also, a way suggested by researchers to reduce solubility and transport of

hydrophobic compounds into filter bed was the use of Fungi (Woertz et al., 2001;

García-Peña et al., 2001). García-Peña et al (2001) described elimination capacity for toluene

up to six times higher than usually reported for bacteria using Paecilomyces variotii. Again for

hexane, which is around 100 times less soluble than toluene, EC between 100 and 150g.m-3.h-1

were obtained by Aspergillus níger (Spigno et al., 2003), while only between 10 and 60g.m-3.h-1

have been reported with bacterial consortia (Budwill and Coleman, 1999; Paca et al., 2001;

Kibazohi et al., 2004).

Page 26: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

16

1.4.4 Parameters used to check the performance of the biological systems

The most common parameters used to check and compare the performance of biological

systems are summarized below (table 3)

Table 3: Performance parameters used in biological treatment systems.

Parameter Formula [unit] Description

EBRT EBRT =

V

Q[𝑠]

EBRT is the time taken by a gas in the biofilter.

Where V= Volume of the reactor (m3)and Q =

the flow of the gas (m3.h-1)

Inlet Load (IL) IL =

Q

Vx Cin[g. m−3. h−1]

This is the amount of the pollutant introduced in

biofilter per unit volume per time. Where Cin is

concentration of pollutants in the inlet gas

stream (g.m-3)

Elimination

capacity

(EC)

EC

=Q

V (Cin − Cout)[g. m−3 . h−1]

This is the amount of the pollutant removed per

volume of a filter bed per unit time

Removal

efficiency

(RE)

RE =(Cin−cout)

Cin x 100 [ %] This is the amount of the pollutant removed in

fraction converted in percentage.

Source: Waweru et al (2000).

1.5 Scope and objectives

Rwanda is a landlocked country whose economy has shown to be increasing since the tragedy

of the 1994 Tutsi’s Genocide (MINECOFIN 2013). Despite the tragedy of Tutsi’s Genocide,

population density (people per km2) is increasing year to year (449 in 2010 and 460 in 2015)

(World Bank, 2016). The basic country’s economic transformation is helped by the industrial,

service delivery and mining sector (Rwanda national institute of statistics, 2011). Industrial

activities and traffic are believed to be the main contributors of high atmospheric emissions in

the country especially in the capital city, Kigali.

Prior to industrial emissions, there are no available abatement technologies for the already

implemented industries. In addition to that, no studies have been conducted before to check

the status of emissions made in different local manufacturing industries. This is a common

problem shared by almost all African countries where data on the concern of air quality status

are hardly or not even found (Do et al. 2013).

Page 27: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

17

To start bridging the gaps, a VOC study was conducted to make a new qualitative and

quantitative data in three different local industries namely Sulfo Rwanda industries producing

soap and cosmetic, Atelier Des Meubles de Kigali (AMEKI) making paints and Inyange industries

producing milk and juices by means of active sampling using Tenax TA tubes and TD-GC-MS

analysis.

This study is divided into two main objectives:

1. To characterize the VOC emitted in three local manufacturing industries, Sulfo Rwanda

Industries, AMEKI color and Inyange industries. Specific objectives on this first part are:

To characterize VOCs emitted in three industries

To identify and comparing the most occurring compounds from Indoor to outdoor in all

industries.

2. To evaluate biofiltration for the cost effective treatment of the waste gases containing

important pollutants, focus given to acetone, dimethyl sulfide and hexane.

Specific objectives on are:

To compare removal efficiencies of the three compounds (acetone, dimethyl sulfide and

hexane) in a biofilter packed with compost, silicon foam and wood chips.

To check the effect of using adsorbing materials, silicon foam, for the removal of

hydrophobic organic, hexane and assess inhibitory effects.

To check the partition coefficient of target VOC to the packing materials.

Page 28: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

18

CHAPTER 2 MATERIALS AND METHODS

This chapter is split into two parts; Part (I) is the analysis of the industrial VOC concentrations

sampled in Rwanda. Samples were taken at three different local manufacturing industries by

means of active sampling using Tenax TA sorbent tubes. After sampling, they were transported

to the environment organic chemistry and technology lab for analysis. Part (II) is the Technology

based part, where biofiltration a cost effective abatement technology was used to evaluate the

removal efficiency of VOC where focus was given to acetone, dimethyl sulfide (DMS) and

hexane as representative VOC.

PART I: ANALYSIS OF INDUSTRIAL VOC CONCENTRATIONS IN RWANDA

2.1 Tenax TA tubes

Tenax TA tubes are tubes filled with sorbent resin (2, 6 diphenylene oxide) to capture VOCs and

semi-VOCs. They have standard dimensions of 1/4 inch (6.4 mm outer diameter x 5 mm internal

diameter), the length of 3.5 inch( 89 mm) and are filled with 200 mg of Tenax TA) (Anon, 2011).

Tenax TA tube can be heated up to 350 °c, has low affinity for water and has a specific surface

area of 35 m2.g-1 and average pore size of 200 nm based on Scientific Instrument Services

(SIS, 2016). The tubes are closed with 1/4 inch brass closure caps (Anon, 2011). The cap has a

white Teflon ferrule (Alltech SF-400T) that creates a better airtight seal. Each tube has an external

groove which indicates the sampling side (Do et al, 2009). The tube can be used more than 100

and after that period the resin should be replaced out of precaution (SIS, 2016).

2.2 Conditioning

Prior to sampling, the Tenax TA tubes should be conditioned to make sure that no residual

components remain on sorbents. Stainless steels, Tenax TA tubes, were put in an oven at 300 oc

for an hour under the flow of 10-50 ml.min-1 helium, to remove all residual components. During

heating oxygen should be avoided to enter since it is detrimental to the adsorbent resin. The

Tenax TA tubes in the oven are positioned with the sampling side mounted out. The oven

(Carlo Erba Instruments, MFC 500) is capable of heating nine tubes all at once.

Page 29: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

19

Figure 7: Conditioning oven

2.2.1 Loading with internal standards

2.2.1.1 Chemicals

Deuterated Toluene (Tol-d8; 99.5%; Acros organics, Geel, Belgium) was used as an internal

standard (IS) (Figure 8).

Figure 8: Tol-d8 structure.

The solvent used for IS is methanol (LC-MS grade, 99.5%, Biosolve, Valkenswaard, Netherlands).

Tenax TA sorbet tubes have low affinity for methanol that’s why methanol was used as a solvent.

The stock solution of 223.7 µg.ml-1 was prepared by putting 24 µL of Tol-d8 in 100 mL of methanol

then kept in total darkness at -18 oC.

2.2.1.2 Preparation of the closed two-phase system

To prepare a gaseous Tol-d8, 20 μL of stock solution was added to 20 ml of deionized water

present in 119.8 mL of a glass bottle. Then, the bottle containing a mixture of stock solution and

deionized water was gas tightly sealed with a mininert valve (Alltech, Lokeren, Belgium) and

incubated in a thermostatic water bath at 25 ± 0.2 oC for 12 hours to assure the equilibrium

between gas and the liquid phase is reached.

D

CD3

D

D

D

D

Page 30: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

20

2.2.1.3 Calculation of the headspace concentration

A given gas and water volumes at a specific temperature with known total mass and Henry’s

law constant of Tol-d8 (Dewulf et al., 1996), the headspace concentration of IS can be

calculated from the mass balance equilibrium. First, the total mass of Tol-d8 (m total) added to

the CTS was equal to 4474 ng. Based on the mass balance and Henry constant of Tol-d 8 at

25 oc (H= 0.183), we can derive,

Equation 15 can be rewritten into Equation. 17

4474 ng =Cair

0.183∗ Vwater + Cair ∗ Vair

(Eq. 17)

Then with Vwater= 20 mL; Vair =99.8 mL, the concentration of Tol-d8 in the headspace can be

calculated as 21.4 (ng.mL-1). This means that 0.5 mL air in the CTS contains 10.7 ng of Tol-d8.

2.2.1.4 Loading

In CTS, 0.5 mL of headspace was taken by 0.5 ml gastight pressure lock VICI precision analytical

syringe (Series A, Alltech). The desired volume was loaded onto the sorbent tubes through an

injection system flushed with helium (He) (flow rate of 100 mL.min-1). And finally, the He stream

was held on for 3 min before the tubes were sealed with ¼ inch brass long term storage

endcaps, equipped with ¼ inch one-piece PTFE ferrules.

2.2.2 Pump Calibration

A Gil Air sampling pump was calibrated before use by Gilibrator to make sure the targeted flow

rate is at least repeatedly obtained, and it was regulated on an average flow rate of 100 ± 0.5 %

mL.min-1 (n = 8).

2.3 Sampling Campaigns

The sampling campaign of VOCs in Rwanda was held at three different local industries namely

Sulfo Rwanda industries, AMEKI color and Inyange industries producing cosmetics, paints and

beverages respectively (Figure 9).

mtotal = mair + mwater=cair × Vair+cwater × Vwater ( Eq. 15)

H =Cair

CWater=0.183 mol.L−1 mol.L−1⁄ ( Eq. 16)

Page 31: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

21

The sampling campaign was performed by means of active sampling using Tenax TA sorbent

tubes (n = 1) at indoor and outdoor of the three local manufacturing industries on 16th July and

30th July 2015 (Table 4). Two samples (one for three minutes and another for 30 minutes) were

sampled indoor and outdoor at each sampling site and two blanks were among sampling Tenax

tubes which remained closed entirely the whole campaign. The three minutes samples are the

one which were analyzed as they were found to be loaded with enough VOC concentrations

for measurements.

(1) Sulfo soap production unit (2) Sulfo cosmetics production unit, (3) AMEKI color for paints (4) Inyange for

juice and milk processing (beverages)

Figure 9 : Sampling locations on the map of Kigali city.

2

1

3

4

1

2

3

4

40 km

Page 32: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

22

Table 4: The overview information of the VOC sampling campaign collected at three local

industries in Rwanda.

Indoor Outdoor Date Time Sample

size

Sampling times

1. Sulfo Rwanda Industries

16-07-2015

11:00-13:50

8 I. Soap production 30 30

3 3

II. Cosmetics 30 30

3 3

2. AMEKI color 30 30 16-07-2015 14:30-16:00 4

3 3

3. Inyange Industries 30 30 30-07-2015 16:00-17:45 4

3 3

2.3.1 Description of the sampling locations

2.3.1.1 Sulfo Rwanda Industries

Sulfo Rwanda Industries is a local manufacturing industry producing drinking water, hard and soft

soap, and cosmetics (body lotion, glycerin and toilet soap). The industry has four production

units. Samples were taken in late morning between 11:00 and 13:50 on 16th July, 2015 at two

manufacturing units, hard soap production and cosmetics unit.

The two production units are built in the middle of a busy place downtown in the capital city; on

the street of soap production unit there is a lot of traffic, big public parking lot at the back and

like in 300 m there is also a big city market hall and other many retailing business around it. The

cosmetic production unit is close to a national museum and prison (Figure 10) and (Figure 11).

Figure 10: Soap production unit. Figure 11: Cosmetics production unit.

Page 33: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

23

2.3.1.2 AMEKI Color

AMEKI color is a paint production company located at the industrial park; it neighbors different

industries and is no far away from a polyclinic and petro station. Samples were taken in

afternoon between 14:30 and 16:00 on 16th July, 2015.

AMEKI color is the leading paint local manufacturing industry in Rwanda. Paints produced are;

(1) latex matt, based on styrene acrylic emulsion, suitable for ceilings and walls internally or

externally whether new or previously painted and (2) Silk Vinyl emulsion, water-based emulsion,

noted to be environmental friendly (Figure 12).

The company is mostly manual based paints production and permanent employees are in

direct contact with the raw products for paint making. Diesel is entirely used for cleaning all used

materials in the process.

Figure 12: Paint production.

2.3.1.3 Inyange Industries

The Inyange industry is located outside the capital, there is no high traffic as compared to the

city center and it is built in the lowland close to marchland. There is little habitation across the

industry. Inyange is the first ranked industry for the production of beverages in the country. Their

daily production is drinking water, juices, milk packaging and milk processing. All production

units are combined in the same site. After the production and packaging, caustic soda is

passed in the tanks for cleaning purposes. Samples were collected in the afternoon from 16:00 to

17:45 on 30th July, 2015 in the milk and juice production units (Figure 13).

Page 34: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

24

Figure 13: Juice and milk production unit.

2.4 Analysis of Tenax TA sampling tubes

2.4.1 TD-GC-MS

Tenax TA tubes used in three sampling campaign location in Rwanda were transported to

laboratory and analyzed by TD-GC-MS in a method described by Do et al (2009) (Figure 14).

Figure 14 : The TD-GC-MS with (1) the TD (2) the transfer line from GC to MS,

(3) GC and (4) MS.

The desorption of analytes pre-concentrated on the Tenax TA sorbent tubes was performed by

a unity 2 thermal Desorption system (Markes, Llantrisant, UK) at 260 oC with 20 mL.min-1 helium

flow for 10 minutes. Each Tenax TA tube was put in the TD system equipped with two special

diffusion caps.

Desorption process was first pre-purged at 34 oC for two minutes to make sure that water vapor is

eliminated inside Tenax TA tubes and then a temperature of 260 oC for 10 min was set to tube

desorption. Next, analytes were refocused on a microtrap 100 % Tenax TA (noC-TNXTA)

(Markes, Llantrisant, UK) cooled at -10 oC. The Tenax TA tubes were heated up sharply from

-10 oC to 280 oC within three minutes.

2

4

3

1

Page 35: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

25

Analytes were carried by a helium flow and injected onto a 30 m factor four VF-1 ms low bleed

bounded phase capillary GC column (Varian, Sint-Katelijne-Waver, Belgium;

100 % polydimethylsiloxane, internal diameter 0.25 mm, film thickness 1µm), after splitting helium

flow at 5 ml.min-1. The column head pressure was set at 50 kPa, resulting into a flow of

1.0 mL.min-1 (at 130 oC) through the GC column.

The GC (Focus GC, Thermo Scientific, Italy) oven temperature was initially set at 35 oC for

10 minutes. Next, the temperature in the GC was increased gradually up to 240 oC into four

stages (1) from 35 to 60 oC (2 oC.min-1), (2) from 60 to 170 oC (8 oC.min-1), (3) from 170 to 240 oC

(15 oC. min-1) and (4) (240 oC) was held for 10 minutes before cooling down to 35 oC. Even

though GC was cooled down, the transfer line from GC to MS was kept at 240 oC.

Mass from m/z 29 to 300 were recorded in full scan mode (200 ms per scan) on a DSQ II.

Quadrupole MS (Thermo Scientific, Austin, TX, USA), hyphenated to the GC, and operating at an

electron impact energy of 70 eV. Chromatograms and mass spectra were processed using

Xcalibur software (Thermo Finnigan, version 2.2)

Compound identifications were predicted based on (i) their fragmentation patterns and by

comparison of their mass spectra with the US National Institute of Science and Technology (NIST,

Gaithersburg, MD, USA) 2.0 database [NIST/US Environmental Protection Agency (EPA)/US

National Institute of Health (NIH) Mass Spectra Library], and (ii) comparison of retention time with

the standards.

2.4.2 Calibration of the TD-GC-MS

To have the correct concentration values, calibration was performed. A total set of 78 LC-MS

grade standard VOCs were used for the calibration.

These VOCs were purchased at the Acros Organics (Geel, Belgium) and/or at Sigma-Aldrich

(Bornen, Belgium) and all had a purity of at least 99.8 %. Methanol (LC-MC grade, 99.95 %,

Biosolve, Valkenswaard, Netherlands) served as a solvent for all standard compounds.

The 78 standards compounds were prepared and divided into three stock solutions (A, B and C)

(in methanol) together with a known mass of Tol-d8. A known volume 1µL of the stock solution

was loaded on two Tenax TA sampling tubes corresponding with a loaded mass between 31.3

and 81.2 ng. For each calibration of the TD-GC-MS, there were six calibration files corresponding

with 2x3 sampling tubes. The six tubes were then analyzed in the TD-GC-MS in full scan mode.

The quantification, data were processed by an extracted ion chromatogram.

Page 36: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

26

The sample response factor (SRFi) in the chromatography is defined as the signal output per unit

mass of the substance injected. Therefore, SRFi can be calculated based on the Equation 18.

Where, Ai is the peak area and mi the mass (ng) of the substance i on the sorbent tube. Based on

the concept of SRF, the RSRF (Relative Sample Response Factor) is defined as the ratio of sample

response factor of the analyte (SRFa) and Tol-d8 (SRFst).

It is worth noting that RSRF is dimensionless. During the calibration of the TD-GC-MS, both

analyses and Tol-d8 were loaded from the liquid phase.

Demeestere et al. (2008) have found RSRF L,L (both loaded from liquid phase) and RSRF G,G (both

loaded from air phase) are the same.

2.5 Quantification

2.5.1 Calculation of the analyte concentration

Since we know (i) the mass of the IS (mst = 10.7 ng as calculated in section 2.2.1.3 from CTS (ii) the

peak areas of the analyte and the IS and (iii) RSRFL,L from the calibration of TD-GC-MS we can

depict the mass of the target compound (ma) on the sorbent in active sampling.

The Volume of the sampled air can be obtained from Eq.23.

SRFi =Ai

mi

(Eq.18)

RSRF =SRFa

SRFst

(Eq.19)

RSRFL,L =SRFa

SRFst

(Eq.20)

RSRFL,L ≈ RSRFG,G =SRFa

SRFst

(Eq.21)

ma =mast × Aa

Ast × SRFL,L

(Eq.22)

Page 37: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

27

And Qsample is the flow rate of the sampling pump and tsample is the sampling residence time. And

the concentration can be calculated as:

All components’ peaks were determined from respective extracted ion chromatographs and

the RSRFL, L was determined from the calibration of the TD-GC-MS. A blank correction was also

performed during the concentration calculations.

V = QSample × tsample (Eq.23)

Ca =ma

V (Eq.24)

Page 38: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

28

PART II: ABATEMENT TECHNOLOGY

2.6 BIOFILTRATION

Given state of the art cost effective abatement technology, biofiltration was used to evaluate

the removal efficiency of VOCs where focus was given to three compounds, acetone, dimethyl

sulfide and hexane.

2.6.1 Physical chemical properties of the representative VOC compounds

The most important physical chemical properties describing acetone, dimethyl sulfide and

hexane are summarized in Table 5.

Table 5: Physical chemical properties of acetone, dimethyl sulfide and hexane.

Parameters Acetone DMS Hexane

Functional group Ketone Sulfur compound Alkane

Molecular weight (g.mol-1) 58.08 62.13 84.17

Odor threshold(ppmv)2 42 0.003 1.5

Boiling point (0C)2 46.5 29.5 68.5

Vapor pressure at 25 0C (mmHg)3 231 502 153

Solubility in H2O at 25 oC( g.L-1)2 94 45 0.016

Henry’s law constant (-) (Cg/CL)1 0.012 0.048 44

1Calculated using the solubility and vapor pressure

2 (Nagata, 2003); 3 (SciFinder, 2016); (Daubert, 1989)

2.6.2 Biofiltration process

2.6.2.1 Biofiltration design

The biofiltrer was built using six identical cylindrical modules of Plexiglas and the total height of

the setup was 1.2 m with internal diameter of 10 cm. The packing materials in the biofilter

occupied only 1 m height and the remained 0.2 m at the bottom was occupied by glassbits

purposed to homogenize gas flow streams before enter the filter bed.

2.6.2.2 Biofiltration setup

The biofiltration setup used in the experiment was divided into three major parts: (A) generation

of the flow air controlled by mass flow controllers (B) the filter bed equally packed by compost,

woodchips and silicon foam and (C) analysis of VOC concentrations and CO2 produced by

Page 39: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

29

SIFT-MS (Syft technology, the Voice 200®, Christchurch, New Zealand) and Vaisala CARBOCAP®

hand held carbon dioxide analyzer (GM70 model, vaisala, Finland) respectively (Figure 15).

Figure 15: Schematic diagram of the biofiltration setup. (1) pressure regulator (PR), (2) mass flow

controllers (MFC1; Q1 = 5 L.mim-1, MFC2 ; Q2 = 2.5 L.min-1, MCF3; Q5 = 0.2 L.min-1 and

Q3= Q1+Q2) (3) acetone bottle, (4) DMS bottle, (5) hexane bottle, (6) pressure control valve, (7)

humidifier column, (8) filter bed, (L1) leachate collection port, (P1) inlet port, (P2), (P3), (P4) and

(P5) are intermediate ports, (P6) outlet port, (9) flow monitoring valve, (10) rotameter, (11) clean

gas exit.

The aim of the setup was to measure the overall performance of the filter bed polluted with

acetone, DMS and hexane. The polluted air flow streams were generated by passing streams of

air into capillaries attached to liquid bottles filled with acetone, DMS and Hexane

(Acros Organics) controlled by mass flow controllers (Brooks Instruments, Mass flow controllers®,

Hartfield, USA). The capillary used for acetone and hexane was 5 cm long and 1/8 inch

diameter, and DMS was 10 cm long and 1/8 inch diameter. They were connected to ¼ inch

white Teflon PFTE tubing which connected the streams in the entire system. The main

Q4

Q3

Q5

Q3

Q1

Q2

2

11

9

1

1

2

2

6

3 4 5

7

L1

1

P1

10

P6

P2

P3

P4

P5

MFC 1

SIFT-MS

CO2

8

A B

b

C

MFC 2

MFC 3

Page 40: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

30

contaminated stream flow (Q3) was pre-humidified in humidifier filled with water before getting

in the filter bed packed equally in volume by compost, woodchips and silicon foam.

The stream (Q3) flows upward in the filter bed which had six measuring ports (i.e. inlet, outlet and

four intermediate measuring ports). The leachate collection port was at the bottom of the filter

bed. Valve on measuring port was manually switched to start a small flow (Q4) that was

analyzed from the big stream (Q3) in the BF. This stream flow (Q4) controlled by valves and

measured with rotameter was diluted with a stream flow (Q5) of nitrogen before reaching

measuring instruments to avoid high concentration in the SIFT-MS. Figure 16 represent the actual

experimental set up for the study

Figure 16: Actual setup of the biofilter (1) PR, (2) polluted bottles, (3) humidifier column,

(4) biofilter, (5) SIFT-MS.

2.6.3 Characterization of the packing materials

The packing materials used for the experiments were compost (port grand, Belgium), woodchips

and silicon foam (sponge cord®, Netherlands). They were mixed and put in a filter bed at equal

volume fractions (1/3 v/v) (Figure 17). The physical chemical properties conducted for the

packing materials were density, moisture content, water holding capacity and porosity.

Figure 17: Packing materials used in biofiltration process. (1) Compost, (2) woodchips and

(3) Silicon foam.

5

2 3

4

1

1

2

3

Page 41: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

31

2.6.3.1 Bulk Density

The apparent density of the three packing materials was measured by weighting packing

materials at ambient conditions into a known volume dimension. The Equation (25) was used to

calculate the bulk density, where mP and VB are weight of the packing material and volume of

used column respectively.

Bulk density =mP

VB

(Eq.25)

2.6.3.2 Moisture content

The moisture content of the packing materials was calculated based on Equation (26) with mP

and mDP the mass of the packing material at ambient conditions and the mass of the dry

packing material after 72 h at 358 K in oven.

Moisture content =mP − mDP

mp

x100 (Eq.26)

2.6.3.3 Water holding capacity

The water holding capacity of the packing materials was calculated by applying Equation (27)

with mw and mWP the amount water poured on the dried packing material and the mass of the

packing material 15 min after pouring water.

2.6.3.4 Porosity

The porosity of the mixed packing materials (1/1/1 volume ratio) was calculated based on an

online method using SIFT-MS. It was calculated as the ratio of net residence time (NRT) over

empty bed residence time (EBRT) (Equation 28). Compounds with high Henry’s law constants

behave as inert compound into biofilter and no degradation and absorption might happen to

such compounds (Volckaert, 2014). Dynamic experiment to calculate the porosity in a first

attempt was done by injecting 10 μL of hexane liquid into the biofilter. No peaks were found at

the outlet port for acetone, DMS and hexane. This can be cause by the interaction of the

packing materials with the contaminants (Figure 18). The second experiment, a 15 ml of

methane (± 35000 ppm) gas was injected and the peaks were recorded by the SIFT-MS to both

Water holding capacity =mWP − mDP

mW

x100 (Eq.27)

Page 42: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

32

inlet and outlet (Figure 19). The net residence time was calculated by subtracting the time of

injection to the top of the peak.

Figure 18: The peak injection experiment of acetone, DMS and hexane.

Figure 19: The peak injection experiment using methane gas.

Table 6 represents the summary of the calculated physical chemical properties.

Table 6: Calculated physical chemical properties of the packing materials.

Packing material

Property (unit) Compost Woodchips Silicon foam

Moisture content (w/w %) 79 23 16

Water holding capacity (w/w %) 76 61 5

Bulky density (g.mL-1) 0.28 0.33 0.13

Porosity of the mixed packing materials (%) 37 ± 1.27

Porosity =

NRT

EBRT

( Eq. 28)

Page 43: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

33

2.6.3.5 Partitioning coefficient determination procedure

Walgraeve et al (2015) developed a new easy and fast online method to calculate the

partitioning coefficient using SIFT-MS. The same method was used to calculate the partitioning

coefficient of acetone, DMS and hexane to the packing materials (compost, woodchips and

silicon foam). Pollutants with constant concentrations were bubbled through a solid phase

(packing material). At this positon, there was phase transfer from gas to solid phase which were

monitored by SIFT-MS.

A small flow F1 (31.92 ml.min-1) of acetone, DMS and hexane leaving the BF controlled by valve

system and measured by rotameter was connected to a four way valve switching system

(SS-43YFS2 Swagelok, Belgian fluid system technologies BVBA, Groot-Bijgaarden, Belgium). Air

stream F2 controlled by mass flow controller was also flowed into a four way valve aimed to

clean the system and blank measurements.

From four way valve, polluted air was fed to a bubble column filled with known weight of

packing material. The concentrations leaving the bubble column was continually measured by

SIFT-MS until the outlet concentrations (cout) becomes equal to the inlet concentration (cin).

The resulted breakthrough curves (see an example on Figure 20) was used to calculate the

dimensionless partitioning coefficient of the packing materials to the pollutants (KPM/air) (mg

[VOC].m-3 [packing material]).(mg [VOC].m-3) [air])-1 (Equation 29) where A is the surface of the

packed material breakthrough curve based on the normalized concentration (outlet over inlet

concentration), B the surface of obtained breakthrough curve of empty bubble column,

Q (m3.min-1) is the flow of the sample concentrations and V (m3) the volume of the packing

material in bubble column.

Partition coefficient =

(A − B) x Q

V

(Eq. 29)

Figure 20: Breakthrough curve of the pollutant to the packing material and blank.

Page 44: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

34

2.6.4 Environmental conditions of the filter bed

2.6.4.1 Temperature

The temperature of the filter bed was simulated based on the room temperature where the

biofilter was placed. The average bioreactor temperature was 18 ± 2 oC.

2.6.4.2 pH

The pH of the system was investigated by analyzing the leachate collected weekly after pouring

nutrients and deionized water in equal volumes at the top of the biofilter using a pH meter

(3310 Jenway, pH meter).

2.6.4.3 Nutrients

To enhance the performance and lifetime of the filter bed a weekly supply of nutrients was used

based on the C: N: P ratio of 100:5:1. A 200ml of nutrients and 200ml of deionized water were the

volumes poured at the top of the filter bed each week. The chemical compounds served as

nutrients to the biofilter were: KH2PO4 (8 g), K2HPO4 (8 g), KNO3 (53.6 g), Vitamin (A, B1, B2, B3, B5,

B8, B9, and D3) (10 mL) and MgSO4 (0.5 g).

2.6.4.3 Pressure drop

The pressure drop measurement of the biofilter bed was made by using a homemade

instrument. It was measured from inlet to outlet port connected to the filter bed. The dimension

of the filter bed influences the pressure drop in the filter bed (Delhoménie & Heitz, 2005;

Álvarez-hornos et al., 2011).

Figure 21: Pressure drop in the filter bed.

The maximum pressure drop difference from inlet to outlet was 137 Pa for the mixed packing

materials. According to literature, to pressure difference obtained using only the compost was

10 mm H2O.m-1 (98 Pa) (Chou and Li, 2009).

Page 45: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

35

2.6.5. Analytical instrumentation

2.6.5.1 Analysis with SIFT-MS

SIFT-MS was used entirely to investigate the performance of the biofilter. It is a real time

quantification technique used to analyze trace VOCs in air and breath related disease (Spesyvyi

2012). It can be used in medicine to diagnose breath diseases, security for the detection of

explosive and toxic substances and in environmental monitoring and food control (Smith et al.,

2005; Španěl et al., 2012).

SIFT-MS use chemical ionization of product ions obtained from the reaction of the sample VOCs

and the injected precursor ions. The formed products ions flow in the mass spectroscopy where

ions are separated by their mass to charge ratios (m/z) and measure count rate in the wanted

m/z (Španěl & Smith, 2001). The unknown concentration of sample can be calculated by using a

library of the rate of coefficient of ion molecular reactions (Spesyvyi 2012). The most frequent

precursors used are H3O+, NO+ and O2+. Table 7 represents the precursor ions used in the method

to measure concentrations in the SIFT-MS.

Table 7: The precursor and products ion used to measure concentrations in SIFT-MS.

Compound Precursor

ions

Mass (m/z) Products

ions

Branching

ratio

Hexane NO+ 85 C6H13+ 100 %

Acetone O2+ 58 C3H6O+ 60 %

DMS O2+ 46 CH2S+ 15 %

2.6.5.2 Analysis with Ion chromatography

Ion chromatography (IC) was used to analyze the major anions in the leachate collected each

week after adding nutrient to the biofilter. Ion chromatography is a form of liquid

chromatography used to measure the concentrations of the ionic species by separating them

based on their interactions with the resin (ion chromatography, 2016). Samples solutions pass

through a pressured chromatographic column where ions are absorbed by column constituents

(ion chromatography, 2016). The eluent runs through the column and the absorbed ions begin

separating from the column and the resulted retention time of different species determines the

ionic concentrations in the samples via conduction (ion chromatography, 2016). IC was

equipped with the cationic resin which made possible to measure the anions content in the

leachate. It is connected to software (chromeleon 7.0) that detects and monitor the amount of

anions found in samples. The anions measured were chloride (CL-), phosphate (PO43-), sulfate

(SO42-) and nitrate (NO3-). For cations ions like Mg2+ and K+ it was not possible to measure them

since the resin was positive.

Page 46: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

36

CHAPTER 3 RESULTS AND DISCUSSION

PART I: INDUSTRIAL VOC ANALYSIS IN RWANDA

Volatile organic compounds were monitored in three different manufacturing industries at the

capital city, Kigali, Rwanda. Samples without replications (n=1) in three manufacturing industries

were collected on July, 16th and 31st July, 2015. After sampling, the analysis of VOC

concentrations was performed by TD-GC-MS (see chapter 2 part I). From the 78 target VOCs, 45

were identified from nearly all samples collected indoor and outdoor of the four different

sampling sites.

3.1 Results

The target 45 VOCs concentrations (μg.m-3), indoor and outdoor, of the four sampling sites are

illustrated in table 8 and 9. Out of 78 target VOC compounds, 33 were not detected in the

sampling campaign. They are 1-pentene, 1-hexene, 1-bromo-4-fluorobenzene,

isobutylaldehyde, 3-methylbutylaldehyde, 1-octanol, 3-methyl-1-butanol, 2-octanone,

5-nonanone, 5-methyl-3-heptanone, n-propylacetate, methylbenzoate, furan, 2-methylfuran,

tetrahydrofuran, chloroform, carbon tetrachloride, 1,3-dichlorobenzene,1,2,4-trimethylbenzene,

1,3,5-triisopropylbenzene, 1,2,-chloropropane, 1,1,2-trichlorotrifluoroethane, trichloroethylene,

tetrachloroethylene, 1,24-trichlorobenzene, 1,1,1,2-tetrachloroethane, dimethylsulfide,

dimethyl disulfide, carbon disulfide, acetonitrile, hexamethyl disiloxane and trimethoxymethyl

silane.

Page 47: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

37

Table 8: Indoor VOC concentrations (μg.m-3) measured at four sampling sites, Kigali, Rwanda

(2015) (ND = Not detected, ∑VOC = Total volatile organic compounds).

Industry name Sulfo AMEKI color Inyange

Product manufactured Soap Cosmetics Paints Beverage

Sampling date 16/07 16/07 16/07 31/07

Sampling time 11:00-12:20 12:30-13:50 14:30-16:00 16:00-17:45

Average temperature(0C) 29 30 29 26

Average relative humidity (%) 33 35 36 38

Alkane

Pentane 297 ND 1214 ND

2-methylpentane 547 ND ND ND

Hexane 27 0.06 46 0.3

Heptane 135 1 1934 3

Octane 51 1 2764 3

Nonane 21 2 3129 3

Decane 8 2 2357 4

Undecane 4 1 1216 3

Dodecane 2 2 718 2

Total 1093 9 13376 17

Cycloalkane

cyclohexane 54 ND 692 ND

Methylcyclopentane 146 ND 423 ND

Total 200 1114

Alcohol

Isopropanol 4 ND 222 9

2-methyl -1-propanol ND ND 79 ND

1-butanol ND ND 578 ND

1-pentanol 10 ND ND ND

2-Ethyl-1-hexanol ND ND 1766 25

Total 14 0 2645 34

Aromatic compounds

Benzene 177 2 303 11

Toluene 540 21 3448 18

Ethylbenzene 132 1 1379 3

o-xylene 201 ND 1968 4

m-xylene 440 2 4480 8

p-xylene 210 1 1999 92

Styrene 5 0 44 1

Phenol 2 1 26 3

Page 48: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

38

Industry name Sulfo AMEKI color Inyange

Product manufactured Soap Cosmetics Paints Beverages

Sampling date 16/07 16/07 16/07 31/07

Sampling time 11:00-12:20 12:30-13:50 14:30-16:00 16:00-17:45

Average temperature(0C) 29 30 29 26

Average relative humidity (%) 33 35 36 38

Propylbenzene 40 0.2 278 0.5

1,2,4 Trimethylbenzene 233 1 1170 4

Total 1980 29 15095 145

Aldehydes

Butylaldehyde ND 33 12 ND

Hexanal 6 ND 15 1

Heptaldehyde 1 ND ND 1

Benzaldehyde 10 3 27 13

Total 17 36 53 15

Ketones

2-Butanone 7 51 370 222

2-Hexanone 37 ND 859 ND

2-heptanone 3 0.02 254 0.41

Acetophenone 21 1 230 6

Total 68 52 1713 228

Esters

Methyl acetate ND ND 486 ND

Ethylacetate 1 1 3838 4

Total 1 1 4325 4

Halogenated compounds

Dichloromethane ND 1 11 ND

1,2 dichloroethane ND ND 2 ND

1,1,2Trichloroethane ND ND 7 ND

1,2 dichloropentane ND ND 1 ND

Chlorobenzene 1 ND 93 ND

Total 1 1 114 0

Nitrogen containing compounds

Benzonitrile 4 1 16 1

Total 4 1 16 1

Terpenes

α-Pinene 1 0.17 ND 0.47

Limonene 2 4 ND 1

Linalool 2 1 750 1

Total 5 5 750 3

∑VOCs 3383 132 39203 446

Page 49: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

39

Table 9: Outdoor VOC concentrations (μg.m-3) measured at four sampling sites, Kigali, Rwanda

(2015) (ND=Not detected, TVOC= Total volatile organic compounds).

Industry name Sulfo AMEKI color Inyange

Product manufactured Soap Cosmetics Paints Beverage

Sampling date 16/07 16/07 16/07 31/07

Sampling time 11:00-12:20 12:30-13:50 14:30-16:00 16:00-17:45

Average temperature(0C) 26 27 29 26

Average relative humidity (%) 42 41 39 40

Alkane

Pentane 2436 ND ND ND

2-methylpentane 214 ND ND ND

Hexane 8 ND 0.0 ND

Heptane 64 1.0 0.4 0.1

Octane 57 0.6 0.3 0.3

Nonane 5 0.9 0.3 1

Decane 4 0.8 0.3 1

Undecane 6 0.7 0.3 1

Dodecane 4 0.3 ND 0.2

Total 2797 4.3 2 4

Cycloalkane

cyclohexane ND ND ND ND

Methylcyclopentane 50 ND ND ND

Total 50 0 0 0

Alcohol

Isopropanol 6 ND 8 ND

2-methyl -1-propanol ND ND ND ND

1-butanol ND ND ND ND

1-pentanol 26 ND ND ND

2-Ethyl-1-hexanol ND ND ND ND

Total 32 0.0 8 0.0

Aromatic compounds

Benzene 48 3.2 0.1 1.3

Toluene 113 16 0.5 1.2

Ethylbenzene 20 1.0 0.1 0.1

O-xylene 24 4 0.2 0.3

m-xylene 58 3 0.2 1

p-xylene 25 3 0.1 0.2

Styrene 1 0.3 ND 0.1

Phenol 1 2 1 1

Page 50: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

40

Industry name Sulfo

AMEKI

color Inyange

Product manufactured Soap Cosmetics Paints Beverage

Sampling date 16/07 16/07 16/07 31/07

Sampling time 11:00-12:20 12:30-13:50 14:30-16:00 16:00-17:45

Average temperature(0C) 26 27 29 26

Average relative humidity (%) 42 41 39 40

Propylbenzene 5 3 0.02 0.03

1,2,4 Trimethylbenzene 28 1.3 0.11 0.3

Total 324 37 2 5

Aldehydes

Butyraldehyde 30 ND ND ND

Hexanal 5 1.4 0.4 1

Heptaldehyde 1 ND ND 0.03

Benzaldehyde 5 7 3 3

Total 41 8 3 4

Ketones

2-Butanone 43 ND ND ND

2-Hexanone 5 ND ND ND

2-heptanone 29 ND 0.11 0.1

Acetophenone 5 3 1 3

Total 82 3 1 3

Esters

Methyl acetate 139 ND ND ND

Ethylacetate 2 3 2 3

Total 141 3 2 3

Halogenated compounds

Dichloromethane ND ND ND ND

1,2 dichloroethane ND ND ND ND

1,1,2 trichloroethane ND ND ND ND

1,2 dichloropentane ND ND ND ND

Chlorobenzene ND ND ND ND

Total 0 0 0 0

Nitrogen containing compounds

Benzonitrile 0.5 1 0.4 0.3

Total 0.5 1 0.4 0.3

Terpenes

α-Pinene 8 ND ND 0.14

Limonene 29 2 ND ND

Linalool 7 0.4 0.2 0.3

Total 44 2.3 0.2 0.5

∑VOCs 3512 58 18 17

Page 51: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

41

3.2 Discussion

3.2.1 General discussion

Today, the sum of all target VOC compounds (∑VOC) value is widely accepted as an important

screening parameter for the overall air quality (Salthammer, 2011). The evaluated target VOCs

concentrations for both indoor and outdoor in four industries were all classified in ten target

chemical groups (alkanes, cycloalkanes, alcohols, aromatics compounds, aldehydes, ketones,

esters, halogenated compounds, nitrogen containing compounds and terpenes). In the indoor,

AMEKI color presented the highest ∑VOC concentrations (39.2 103 µg.m-3), 12 times higher than

Sulfo making soap (3.38 103 µg.m-3) and 298 times for cosmetics (0.132 103 µg.m-3), and 88 times

higher than Inyange which makes beverage (juices and milk) (0.45 103 µg.m-3).

On the other hand, the ∑VOC outdoor concentrations measured around the premises of Sulfo

industry making Soap (3.51 103 µg.m-3) was the highest among the other sampling sites. The

concentrations in Sulfo, cosmetics production unit was (0.58 102 µg.m-3), AMEKI color for paintings

(0.18 102 µg.m-3) and (0.17 102 µg.m-3) for Inyange producing beverages (juices and milk). It can

be seen that there was a big variation of ∑VOC measured concentrations indoor and outdoor

of the four sampling sites. To avoid the skewness of the measured total concentrations for both

indoor and outdoor concentrations, a logarithmic scale was used to present the total VOC

concentrations of indoor and outdoor concentrations of the sampling sites (Figure 22).

Figure 22: The total indoor and outdoor concentrations of four sampling sites.

Page 52: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

42

The concentrations of the ten targets chemical groups for both indoor and outdoor in the four

sampling locations were presented in stacked column (Figure 23 and Figure 24).

Figure 23: The indoor total VOC concentrations of chemical groups in four sampling sites.

Figure 24: The outdoor total VOC concentrations of chemical groups in the four sampling sites.

All the target compounds in the aromatic group were present and measured for both indoor

and outdoor of the four sampling sites. This has made aromatics to be more abundantly in both

indoor and outdoor sampling sites, followed by alkanes and ketone. In the indoor sites, the most

groups contributing to the higher VOC concentrations than the others were aromatics 59 % for

soap production unit, ketone 39 % for cosmetics, aromatics 39 % for paints production and 51 %

ketones in juice and milk production (beverage)(Figure 25).

1 2

1 2 3

3

1 2 3

1 2 3

Page 53: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

43

The previous sampling campaign conducted not in industry but in house and urban places in

Vietnam, Bangladesh and Ethiopia also confirmed that the aromatics compounds were

abundantly occurring as compared to other target VOC (Do et al. 2013).

Figure 25: Indoor target groups’ abundances in four sampled sites.

However, in the outdoor sites the highest contributing chemical VOC groups were alkanes with

79 % outdoor of soap production unit, 63 % of aromatics for cosmetics, 44 % alcohols for paints

making and 28 % again aromatics in the beverage production unit. Halogenated compounds

were not found outdoor in all sampling locations. Cycloalkanes were only present at the soap

production units (Figure 26).

Figure 26: Outdoor target groups’ abundance in four sampled sites.

Page 54: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

44

Benzene is mostly viewed as an indicator for the human health effects (Stranger et al., 2007).

According to World Health Organization (WHO), the concentrations of airborne benzene that

are associated with an excess life-time risk of leukemia of 1/10000, 1/100000, 1/1000000 are 17,

1.7 and 0.17 μg.m-3 respectively (WHO Regional Office for Europe, 2010). The monitored indoor

benzene concentrations exceeded the WHO guideline; in Sulfo (for soap production unit was

117 μg.m-3 and 2 μg.m-3 for cosmetics production unit), 303 μg.m-3 for AMEKI color (paints

production) and 11 μg.m-3 for Inyange industry (juice and milk processing). For the outdoor

concentrations levels, in Europe it is restricted to just 5 μg.m-3 on annual average

(Do et al., 2013). This value was exceeded in Sulfo for soap production unit, 48 μg.m-3.

Nevertheless, it should be point out that, the analysis of the results was temporally restricted

based on the monitored concentrations made at selected local industries in Rwanda for a

defined period of time with limited number of measurements while the guideline often sets

concentrations for long time exposure (e.g. the ambient EU limit for benzene is

for 1 year).

3.2.1 Indoor to outdoor concentrations of the sampling sites

The ratio of indoor and outdoor concentrations is very important for VOC sources identification.

The indoor to outdoor concentrations ratio are often found to be higher than one

(Beak et al., 1997; Jia et al., 2008) and can reach up to 100 times (Caselli et al., 2009). The indoor

to outdoor concentrations ratio of the four industrial sites are illustrated in Table 10.

Table 10: Indoor to Outdoor ratio concentrations of the four sampling sites.

Measured concentrations

(µg/m3)

I/O ratio Sampling Location-products Total Indoor (I) Total outdoor (O)

Sulfo-soap 3.38 103 3.51 103 0.96

Sulfo-cosmetics 0.13 103 0.06 103 2

AMEKI-paints 39.2 103 0.02 103 2161

Inyange-beverages 0.45 103 0.02 103 26

The observation from Table 10 indicates that the I/O ratio of Sulfo, soap production unit, is less

than one which implies that there is a strong outdoor VOC sources compared to the indoor

sources. This is true because of the location of this production unit. It is located in a busy place

downtown of the capital city, with a lot of traffic, close to public transportation parking lot,

market (see chapter two). Usually, vehicles used in Rwanda are old and they do not have

exhaust controlling device (catalyst) which implies that there is high VOC concentrations

Page 55: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

45

emitted by cars. Also same industry side of cosmetics production unit, the I/O ratio is 2, shows

main sources to be from the indoor concentrations but there could be slight contributions from

the outdoor concentrations since the unit production is also situated few meters from the road.

The other two industries show strong indoor sources as compared to the outdoor. The total

indoor VOC concentrations could not be only from the VOC emitted from the production

process but also from leaks of the solvent storage tanks.

Page 56: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

46

Part II: BIOFILTRATION OF VOC

3.3 Results and discussion

The traditional biological treatments of VOC are cost effective abatement technologies as

compared to physical chemical technologies. Biofiltration is an easy and affordable biological

abatement technology for VOC. This part of study was aimed at evaluating the performance of

biofilter when polluted with VOC where focus was given to acetone, dimethyl sulfide and

hexane. The main parts discussed were: (i) partition coefficient of pollutant to the packing

materials (ii) general biodegradation reaction of acetone, DMS and hexane, (iii) concentration

profile and removal efficiency, (iv) elimination capacity in function of Inlet load of each

pollutant, (v) the produced carbon dioxide in function of elimination capacity of the mixed

compound, (vi) sulfate collected in function of inlet concentration of DMS,(vii) effect of pH on

removal efficiency, (viii) effect of silicon foam on the removal of hexane and (ix) Check the

inhibitory effects.

3.3.1 Partition coefficient of the pollutants to the packing materials

The transfer of the pollutants from air phase to liquid and or solid phase is important for the

success of the vapor phase biotechnologies. Partitioning coefficient is the ratio of a

contaminant concentration in the solids/water phase to contaminant concentration in the air

phase of the biofilter at equilibrium (Hodge & Devinny, 2010). Determining the constants under

realistic conditions is difficult since the transfer and biodegradation happen simultaneously in

active biofilters (Hodge &Devinny, 2010). With a new method developed by Walgraeve et al

(2015) to calculate the partitioning coefficient using SIFT-MS, it was possible to investigate the

phase transfer of the pollutants, acetone, DMS and hexane in gas phase to solid phase of the

packing materials. The breakthrough curve of the compounds depends on the mass of the

packing material, humidity, temperature and the flow rate (Walgraeve et al., 2015). The resulted

breakthrough curves were concentrations of target VOC (acetone, DMS and hexane) from

bubble column packed one at time with compost, silicon and woodchips monitored by SIFT-MS.

The experiment was carried out for dry packing materials (compost, silicon and woodchips) and

ambient condition of the packing material (used compost only). For dry packing materials, the

flow, relative humidity (RH) and temperature of the mixed VOC leaving packed bubble column

was 390 mL.min-1 for the silicon foam (RH = 25.8 % at 20.8 oc), 390 mL.min-1 (RH = 7.55 % at 20.7 oc)

for the compost and 400 mL.min-1 (RH = 5.73 % at 20.9 oc) for the woodchips experiment (see

example of the breakthrough curves in the appendix II section).

Page 57: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

47

The relative humidity and temperature were measured by humidity meter (Humidity meter

testo® 625, USA). The experiment was also conducted on the compost at ambient condition

(taken from the bag as it is); the flow of stream leaving the bubble column packed with

compost was 395 ml.min-1 (RH = 98.8 % and 21 oc). It should be noted that, the blank experiment

(empty bubble column) was carried out for the correction of the determined partitioning

coefficient. The blank bubble column was at 29 % of relative humidity and 20.9 oc (see an

example in the appendix II section). Table 11 represents the calculated partitioning coefficient

of acetone, DMS and hexane to dry parking materials.

Table 11: Calculated partitioning coefficients of the dry packing material

(mg [VOC].m-3[packing]).(mg[VOC].m-3)[air])-1.

Partition coefficient (KPM/air)

(mg [VOC].m-3[packing]).(mg[VOC].m-3)[air])-1,(RSD)

Bulk density = 0. 13 g/mL Bulk density = 0.33 g/mL Bulk density = 0.28 g/mL

Silicon foam n Woodchips n Compost n

Acetone 3.77 102 (12 %) 3 2.69 101 (8 % ) 2 0.89 103* 1

DMS 1.23 102 (24 %) 3 0.24 101 1 0.12 103 (22 %) 2

Hexane 2.12 102 (14%) 3 0.16 101 1 0.59 103 1

(*) This is an indicative partitioning coefficient value because the concentration did not reach the

equilibrium.

The results in table 11 based on the bulk density indicate acetone to have a high partitioning

coefficient in all dry packing materials than DMS and hexane. That said, acetone is highly

adsorbed to the packing materials than DMS and hexane. If partitioning coefficient was applied

to the packing materials with their real density silicon form would expect to have higher

partitioning coefficient than other packing materials. Figure 27 represents partitioning coefficient

of acetone, DMS and hexane to the dry compost, woodchips and silicon foam.

Figure 27: Partitioning coefficient of acetone, DMS and Hexane

(mg [VOC].m-3[packing]). (mg [VOC].m-3)[Air])-1.

Page 58: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

48

For compost at ambient conditions, the calculated partitioning coefficient (KPM/air) of acetone

was (1.48 102mg.m-3/mg.m-3), DMS (0.05 102mg.m-3/mg.m-3) and hexane (0.02 102mg.m-3/mg.m-3)

which found to be lower than the partitioning coefficient calculated for dry packing materials

(Table 11). At 600 minutes no equilibrium of acetone were reached for dry compost while 90 % of

breakthrough curve was reached to the compost at ambient conditions, this can be explained

by the water vapor molecules which were bound to the packing material that has reduced the

surface of the compost which resulted in faster breakthrough curve. For DMS, the time needed

to obtain equilibrium was 80 minutes for compost at ambient condition and 100 minutes for the

dry one. The equilibrium for hexane was obtained after 10 for compost at ambient conditions

and 40 minutes for dry compost.

According to Hodge and Devinny (2010) in a mathematical model they developed to calculate

the partitioning coefficient of the packing materials, they have indicated that when the

partitioning coefficient is low, the contaminant is more less not adsorbed by the water or

packing material, moves at the same speed as the air and on the contrary when it’s partitioning

coefficient is high the contaminant is retained for a long time and the breakthrough is delayed

(Hodge &Devinny, 2010). The delay for the equilibrium for the dry packing materials were also

observed in the online method used to calculate the partitioning coefficient of the packing

materials using SIFT-MS.

3.3.2 Biological oxidation of pollutants.

A stream of contaminated pollutants was fed into the filter bed upward packed with compost,

woodchips and silicon foam. At this point in the filter bed, there is phase transfer where by

pollutant in gas phase is changed into liquid and or solid phase. Therefore, the pollutant in l iquid

and or solid phase is ready to be used by microorganism. Microorganism populations use

pollutant(s) as carbon and energy source for their maintenance and growth (Kumar et al., 2011).

At favorable conditions (temperature, humidity, pH, etc.) they break down pollutants into less

harmful compounds, carbon dioxide, water, new biomass and other by products e.g. SO42-.

Acetone and hexane were transformed in carbon dioxide and water (Equation 20 and 32). DMS

was transformed into carbon dioxide, sulfuric acid and water (Equation 31).

CH3COCH3 + 4O2 3 CO2+ 3 H2O (Eq. 30)

CH3SCH3+ 5O2 H2SO4 + 2CO2+ 2H2O (Eq. 31)

CH3CH2CH2CH2CH2CH3 + 9.5 O2 6CO2+ 7H2O (Eq. 32)

Page 59: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

49

3.3.3 Bioreactor bed

The setup has been in operation for six months. The filter bed had a volume of 7.85 L, gas flow

rate of 8.21 L.min-1 and operated by this means at an EBRT of 57 s. The average temperature of

the bioreactor was 18 ± 2 oc. The biofilter started up without inoculation and the evolution of the

microbial activity degrading acetone, DMS and hexane at all position of the filter bed for the first

three weeks (taking 1 day at end of each week) is indicated in Figure 28. At day 8, acetone at

the outlet port was already degraded at 99.9 %. DMS was removed at 20, 50 and 91 % for day 8,

15 and 22 respectively. Hexane was degraded at 18 % (day 8), 47 % (day 15), and 45 % (day 22).

Figure 28: The normalized start up concentrations of acetone, DMS and hexane at EBRT of 57 s.

The overall performance parameters of the biofilter (average concentrations and standard

deviation) are summarized in Table 12. The removal efficiency was calculated based on the

ratio of the total elimination capacity over total inlet load concentrations of the three

compounds.

Table 12: Performance parameters of the biofilter.

Phase Days pH IL (mg C.m-3.min-1) EC(mg C.m-3.min-1) RE (%)

I 0 - 23 6.08 ± 0.03 49 ± 16 20 ± 14 20 ± 12

Starvation period

II 40 - 50 5.68 ± 0.19 25 ± 3 12 ± 2 49 ± 9

III 51 - 76 4.57 ± 0.08 16 ± 2 7 ± 2 41 ± 10

IV 77 - 108 5.52 ± 0.53 16 ± 4 8 ± 4 73 ± 12

V 109 - 138 7.09 ± 0.09 22 ± 5 17 ± 4 74 ± 5

VI 139 - 151 7.20 ± 0.03 24 ± 3 17 ± 2 71± 2

VII 152 - 170 6.87 ± 0.04 15 ± 6 11 ± 4 73 ± 7

Hexane measurement only

VIII 171-181 6.20 ± 0.14 6 ± 1 4 ± 3 64 ± 3

Page 60: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

50

The results from the Table 12 indicates that the highest removal efficiency of the target VOC

mixture was at 74 % for IL of 22.36 ± 4.80 mg C.m-3.min-1 and EC of 16.63 ± 4.07 mg C.m-3.min-1 at

an empty bed residence time of 57 s. The evolution of total inlet flow concentrations and total

removal efficiency of the mixed three pollutants (acetone, DMS and hexane) in biofilter for the

entire time in operation is plotted in Figure 29. Different phases were presented; phase I, shows

the startup of the biofilter which was fed with nutrients and the inlet concentrations were

increasing. Phase II, nutrients concentrations were fed into the system again after starvation

period. Phase III, indicated a period of low pH even though biofilter kept fed by nutrients. Phase

IV showed the pH recovery by using 0.1 M potassium phosphate buffer solution (KH2PO4 and

KHPO4 at pH 7.5). From phase V to VII, pH was maintained at optimum by feeding, buffer solution

and deionized water and recycled of leachate in absence of buffer solution using only nutrients

solution at pH 6.78. Phase VIII indicated the period of hexane measurement only.

Figure 29: The Total inlet concentrations ( ) and total removal efficiency ( ) of the

three pollutants at EBRT of 57 s.

Inlet load concentration and maximum elimination capacity are two crucial parameters

characterizing the success of biofilters (Gracy et al., 2006). The individual elimination capacity in

function of the inlet concentration of acetone, DMS and hexane capacity of each pollutant is

given in Figure 30. The black dots explain stable inlet concentrations in the biofilter, the red ones

(B) show an increase of inlet concentrations, which takes sometimes for microorganism to adapt

to such concentrations. The blue dots (A) indicate the highest maximum EC reached for each

compound. The maximum EC of acetone was 20.93 mg.m-3.min-1 at IL of 20.93 mg.m-3.min-1

Page 61: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

51

(99.9 % removal), DMS was 25.82 mg.m-3.min-1 at IL of 34.85 mg.m-3.min-1 (74 % removal) and

31.68 mg.m-3.min-1 at inlet concentration of 67.33 mg.m-3.min-1 (47 % removal efficiency) for

hexane.

Figure 30: EC in function of IL of acetone, DMS and hexane at an EBRT of 57 s.

3.3.4 The Carbon dioxide (CO2) and Elimination capacity (EC)

Vaisala was an instrument behind the measurement of CO2 produced in the biofilter. The CO2

monitored at all ports in function of the days followed the degradation profile of acetone, DMS

and hexane measured by SIFT-MS. Figure 31, represent CO2 produced (PCO2)at the outlet port of

the biofilter in function of total elimination capacity of the three compounds for the stable inlet

concentrations in the biofilter. The PCO2 plotted data ranged from 5.75 to13.54 mg C.m-3.min-1.

Page 62: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

52

Figure 31: Produced CO2 in function of total EC at an EBRT of 57 s.

Figure 31 depicts the proportion ratio between total EC and CO2 produced (PCO2) indicating

that 0.873 mg PCO2.m-3.min-1 was formed for each 1 mg of the target VOCs.m-3.min-1 reduced.

To simplify, it means that 87 % of the total EC in mixture is transformed into CO2 and the

remaining 13 % is possibly shared either to biomass or rinsed away into leachate.

3.3.5 The effect of pH on the removal of target VOC

Biofiltration of target VOCs which produce acids overtime lowers pH that result in decline of

microorganism populations and activity (Shekher et al., 2014). DMS is a sulfur containing

contaminants that is oxidized to sulfuric acid (see section 3.3.2) which was mainly responsible for

acidifying the BF packing materials. The supply of 0.1 M potassium phosphate buffer solution at

25 oc (mixture of KH2PO4 and KHPO4 at pH=7.5) proved to overcome the acidity in the filter bed.

Pollutants removal efficiency in function of pH for the entire setup in operation is given in

Figure 32. The removal efficiency of acetone remained to be 99.9 % for pH = 6.9 and pH = 4.51.

DMS dropped from 99.6 to 39 % at pH = 6.9 to pH = 4.51 and hexane dropped from 57 % to

21 % at pH = 6.9 to pH = 4.51 respectively. The pH was maintained at optimum value and the

removal efficiency kept decreasing which can be possibly explained by the die off

microorganism. The arrows in the figure indicate the increase of the removal efficiency after

adding nutrients to the BF. That effect was seen to the DMS and hexane degradation not to

acetone.

Page 63: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

53

Figure 32: RE in function of pH of acetone, DMS and hexane at an EBRT of 57 s. Arrows indicate

increase of RE after supply of nutrients to the biofilter kept at the optimum pH.

3.3.6 Sulfate measurement

Sulfate ions in the leachate resulted from the oxidation of DMS and magnesium sulfate (Mg SO4)

the nutrient ingredients. They were measured in leachate using ion chromatography. Because of

the influence of the DMS inlet concentrations and additional of nutrients in the BF, it is difficult to

account which one participated in increase or decrease of sulfate anions into leachate. There

are two metabolism pathways of DMS, one is sulfuric acid collected in leachate and another

sulfur is assimilated by microorganism for the cell material (Shekher et al., 2014).

A sulfur balance was conducted to the incoming sulfur concentrations going to the biofilter

(from DMS and Mg SO4) and SO4 leaving the biofilter through leachate. The concentrations of

sulfate in leachate used to be collected once a week and the in between days’ concentrations

Page 64: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

54

were assumed to be constant for days where measurements were not taken for calculation.

It was found out that for a period of 110 days, the total amount of sulfur (from DMS and Mg SO4)

given to the biofilter was 6 g and 11 g of sulfur (from sulfate) were collected in the leachate.

These are indicative values because of the expectation that change of inlet concentrations

might balance with the amount of sulfur in the leachate.

3.3.7 Effect of Silicon on the removal of hexane

The biofiltration of the hydrophobic pollutants is often limited by the gas transfer to liquid and or

solid phase (see section 1.5.3). Silicon foams are used in aerospace, aviation, electronics and

chemicals (IKSonic, 2016). Because of possible sorption capacity of VOC, it was mixed with

compost and woodchips in biofilter to see how target VOC will be degraded especially hexane.

The observed maximum removal efficiency of hexane resulted in biofilter packed with compost,

woodchips and silicon foam was 57 % at IL of 8.46 mg.m-3.min-1 and EC of 4.05 mg.m-3.min-1 to an

EBRT of 57 s. The research made on the degradation of hexane using two types of packing

material, peat (50 % w/w) and perlite (50% w/w) showed a removal concentration of 40 % at a

flow 20 g.m-3.h-1(333 mg.m-3.min-1) (Kibazohi et al., 2004). For biofilter which started up without

inoculation, evidence is needed to prove that the silicon foam has an effect on the removal

efficiency of hexane.

3.3.8 Inhibitory effect for hexane degradation

Among the three compounds used to investigate the performance of the biofilter acetone was

an easiest compounds accessible source for microorganism(s) which could cause the inhibition

of the biodegradation of the hexane. In study conducted by Bruneel (2013) showed that the

presence of acetone proved to inhibit the removal of hexane while removal DMS followed the

same trend with hexane (Bruneel, 2013).

In this study, the last phase of the biofilter in operation (phase VIII) was used to investigate the

removal efficiency of hexane by removing streams of acetone and DMS into the system. For 10

days run of hexane only in the BF indicated a higher removal efficiency than it was in the mixture

(Figure 35). On average for hexane only in BF, the EC was 4.15 ± 2.96 mg.m-3.min-1 at IL of

6.45 ± 0.54 mg.m-3.min-1 which corresponds to 64 ± 3 % RE on average. The total RE of hexane in a

mixture on average for the entire period of biofilter was 33 ± 10 % at IL of 18 ± 15 mg.m-3.min-1

and EC of 6 ± 6 mg.m-3.min-1.

Page 65: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

55

Figure 33: The EC in function of IL for hexane in mixture and hexane only at EBRT of 57 s.

0

10

20

30

40

50

0 10 20 30 40 50

EC H

exan

e (m

g.m

-3. m

in-1

)

IL Hexane (mg.m-3.min-1)

Hexane in mixture Hexane only

Page 66: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

56

CHAPTER 4 CONCLUSION AND RECOMMENDATION

4.1 CONCLUSION

Rwanda is an interesting African country reporting a remarkable economic transformation for

the last decade. Industrial activity is one of the mostly income generating for the country. Local

manufacturing industries are increasing day to day where a lot of emissions are encountered

and technologies to handle such emissions especially the volatile organic compounds in the

country are yet to be established.

In the first part of this work, VOC were monitored at three local manufacturing industries in

Rwanda through one time sampling campaign indoor and outdoor without replication on 16th

July, 2015 to Sulfo Rwanda industry producing soap and cosmetic and AMEKI color which makes

paints and on 30th July, 2015 at Inyange producing beverages (juices and milk processing).

Samples were taken by means of active sampling using Tenax TA sorbent tubes. After sampling,

they were transported to the environment organic chemistry and technology (EnVOC) lab for

analysis. The analysis was made by TD-GC-MS. In the second part of the work, technology part,

biofiltration was used to evaluate the removal efficiency of VOC where focus was given to

acetone, dimethyl sulfide (DMS) and hexane as representative VOC. These compounds where

chosen because of the wide range of physical chemical properties.

This research has brought forward new data on 45 VOCs concentrations levels to both indoor

and outdoor environment of the three local manufacturing industries. By making use of ∑VOCs

and chemical groups, a direct comparison for the VOCs concentrations monitored in three local

manufacturing industries was made. In sulfo, soap production unit, the ∑VOCs indoor and

outdoor were 3.38 103 and 3.51 103 μg.m-3 respectively. Still at sulfo, cosmetic production unit, the

∑VOCs was 0.13 103 μg.m-3 for indoor and 0.06 103 μg.m-3 for outdoor. For paints making industry,

the indoor and outdoor was 39.2 103 and 0.02 103 μg.m-3 respectively. At Inyange, the ∑VOCs

encountered indoor and outdoor were 0.45 103 and 0.02 103 μg.m-3 respectively. Aromatics

compounds where found to be the most contributing chemical group to the ∑VOCs monitored

in all industries followed by the alkanes and ketones groups.

As expected the indoor concentrations levels were higher than the outdoor concentrations

which simply means that most VOC contributing to indoor sources are within the production

area. The only exception was to Sulfo, soap production unit, where indoor concentrations were

less than outdoor concentrations and at this condition it is hard to identify the source of VOC

since the contribution is from both indoor and outdoor concentrations. Soap production unit is

located downtown where a lot of activities are happening and this could define the raison why

Page 67: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

57

the outdoor source is high as compared to the indoor. The benzene level was higher than the

guidelines of the WHO indoor concentrations for Sulfo (117 μg.m-3 for soap production unit and

2 μg.m-3 for cosmetics production unit), 303 μg.m-3 for AMEKI color (paints production) and 11

μg.m-3 for Inyange industry (juice and milk production). The outdoor at Sulfo part of soap

production unit, the concentrations (48 μg.m-3) was found to be higher than the EU directive on

the outdoor benzene limit (5 µg.m-3).

The second part of this research, the technology part, biofilter equally packed (1/3 w/w) with

compost, woodchips and silicon foam was used to investigate the removal efficiency of the

representative target VOC, acetone, DMS and hexane. SIFT-MS (for IL and EC) and Vaisala

(CO2) were two major instruments used to record concentrations of the microorganism

degradation behavior.

The performance assessment of the biofilter was done by comparing inlet concentrations,

elimination capacity and removal efficiency of the target compounds mixed altogether. The

maximum removal efficiency of the mixed compounds was 74 ± 5 % at IL of

22.4 ± 4.80 mg C.m-3.min-1 and EC of 17 ± 4 mg C.m-3.min-1 at EBRT of 57 s. Based on the

partitioning coefficient experiment, acetone was found to be highly adsorbed to all packing

materials followed by DMS and hexane. Based on the removal of individual compound, the

maximum EC of acetone was 20.93 mg.m-3.min-1 at IL of 20.93 mg.m-3.min-1

(99.9 % removal), DMS the maximum EC was 25.82 mg.m-3.min-1 at IL of 34.85 mg.m-3.min-1 (74 %

removal) and for hexane the maximum EC was 31.68 mg.m-3.min-1 at inlet concentration of

67.33 mg.m-3.min-1 (47 % removal efficiency).

The experiment of hexane as contaminants only in the biofilter showed to be higher than when

mixed with acetone and DMS. The high removal of hexane was also contributed by the silicon

foam used in the mixture of packing material. To conclude, based on this performance,

biofiltration can be seen as an urgent technology for the treatment of the target VOC in

manufacturing and production industries.

4.2 RECOMMENDATION

The samples taken in three local manufacturing industries gave us an insight on the level of VOC

emissions in three manufacturing industries, a further study can be also conducted to the same

industries by taking more sample replications at different times to see when and how VOC

variate. Another recommendation, for the biofiltration setup, further studies can be conducted

to check the responsible microorganism(s) for the degradation of acetone, DMS and hexane.

Page 68: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

58

REFERENCES

A. Kundu, E. Dumont, A.-M. Duquenne, H. Delmas (2003). Mass transfer characteristics in gas

liquid liquid system, Can. J. Chem. Eng. 81: 640–646

A.D. Dorado, E. Dumont, R. Muñoz, G. Quijano (2015). A novel mathematical approach for the

understanding and optimization of two-phase partitioning bioreactors devoted to air

pollution control, Chem. Eng. J. 263: 239–248

AEA group (2007). Climate change consequences for VOC Emission Controls. A Report to the

Department for Environment, Food and Rural Affairs, Welsh Assembly Government, the

Scottish Executive and the Department of the Environment for Northern Ireland

Agency for toxic substances and disease Registry (ATSDR) (1997). Toxicological Profile for

Hexane. Public health service, U.S. Department of Health and Human Services, Atlanta,

GA.

Alarie Y, Nielsen GD, Andonian-Haftvan J, Abraham MH (1995). Physicochemical properties of

nonreactive volatile organic chemicals to estimate RD50: alternatives to animal studies,

Toxicol Appl Pharmacol; 134 (1):92-9

Albritton, Daniel,(1998) “What Should Be Done in a Science Assessment In Protecting the Ozone

Layer: Lessons, Models, and Prospects,”.

Álvarez-hornos, F. J., Sempere, F., Izquierdo, M., & Gabaldón, C. (2011). Lab-scale Evaluation

of Two Biotechnologies to Treat VOC Air Emissions: Comparison with a Biotrickling Pilot

Unit Installed in the Plastic Coating Sector.

Angell, J. K., and J. Korshover (2005). “Quasi-biennial and Long-term Fluctuations in Total Ozone,”

Monthly Weather Review vol. 101, pp.426–43

Armon, R., Laot, N., Lev, O., Shuval, H., and Fattal, B. (2000). Control- ling biofilm formation by

hydrogen peroxide and silver combined disinfectant. Water Science & Technology.

42(1–2): 187–193

Bari, A., Kindzierski, W. B., Wheeler, A. J., Eve, M.-, & Wallace, L. A. (2015). Source apportionment

of indoor and outdoor volatile organic compounds at homes in Edmonton , Canada, 90.

Batterman S, Jia C, Hatzivailis G. (2007). Migration of volatile organic compounds from attached

garages to residences: a major exposure source. Environ Res; 104:224-40.

Blondel A, Plaisance H.(2011). Screening of formaldehyde indoor sources and quantification of

their emission using a passive sampler. Build Environ; 46:1284-91.

Bohn H (1992). Consider biofiltration for decontaminating gases. Chem Eng Prog 88:34–40

Bruneel, J. (2013). Evaluatie van de simultane verwijdering van aceton, dimethylsulfide, hexaan,

tolueen en limoneen door twee biofilters in serie, 1–73.

Page 69: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

59

Budwill K, Coleman R. (1999). Biofiltration of gaseous emissions from forest products

manufacturing. Microbiology research and development. Environmental Technologies

Alberta Research Council. Canada.

Burrows, J., Cox, T., Fowler, D., Granier, C., Isaaksen, I., Monks, P., … Borrell, P. (2007). Transport

and Transformation of Pollutants (T & TP ), Remote Sensing from Space (AT2 ), Access to

Emissions , Access to Laboratory Data , Volatile Organic Compounds in the Polluted

Atmosphere.

C. Easter, C. Quigley, P. Burrowes, J. Witherspoon and D. Apgar (2005). Chem. Eng. J. 113, 93

C. Jia, S. Batterman, and C. Godwin (2008). Atmos. Environ. 42, 2083

C. Kennes, E.R. Rene and M.C. Veiga, J. (2009). Chem. Technol. Biotechnol. 84, 1419

Cai, Z., Kim, D., and Sorial, G. A. (2004). Evaluation of trickle-bed air biofilter performance for MEK

removal. Journal of Hazardous Materials. 114(1–3): 153–158

Cetin E., Odabasi M., Seyfioglu R.(2003) Ambient volatile organic compound (VOC)

concentrations around a petrochemical complex and petroleum refinery. Sci. Total

Environ: 312, 103-112.

Chen, X., and Stewart, P. S. (2000). Biofilm removal caused by chemical treatments.Water

Research. 34(17): 4229–4233

Christen, P., Domenech, F., Michelena, G., Auria, R., and Revah, S. (2002). Biofiltration of volatile

ethanol using sugar cane bagasse inoculated with Candida utilis. Journal of Hazardous

Materials. 89(2–3): 253– 265.

Chung YC (2007). Evaluation of gas removal and bacterial community diversity in a biofilter

developed to treat composting exhaust gases. J Hazard Mater 144:377–385.

Clark, O.G., I. Edeogu, J. Feddes, R.N. Coleman and A. Abolghasemi (2004). Effects of operating

temperature and supplemental nutrients in a pilot- scale agricultural biofilter. Canadian

Biosyst. Eng., 46: 7-16

Clayton, G.D and F.E Clayton (1998). Patty’s industrial Hygiene and Toxicology: Volume 2A, 2B,

2C: Toxicology .3rd ed New York, John Wiley Sons, 1981-1982.p.2065

Cox, H. H. J., and Deshusses, M. A. (1997). The use of protozoa to control biomass growth in

biological trickling filters for waste air treatment. In: Proceedings of the 90th Annual

Meeting & Exhibition of the Air &Waste Management Association. June 8–13, Toronto.

Cox, H. H. J., and Deshusses, M. A. (1999). Chemical removal of biomass from waste air

biotrickling filters Screening of chemicals of potential interest.Water Research. 33(10):

2383–2392

Page 70: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

60

Crocker, B. B., and Schnelle, K. B. (1998). Air pollution control for stationary sources. In

Encyclopedia of Environmental Analysis and Remediation. pp. 150–169. Vol. 1. Meyers, R.

A., Ed., JohnWiley & Sons, New York

D. Gabriel, J.P. Maestre, L. Martín, X. Gamisans and J. Lafuente. (2007). Biosyst. Eng. 97, 481

Daubert T.E, R.P. Danner (1989). Physical and thermodynamic Properties of pure chemicals Dara

Compilation, Washington, DC: Taylor and Francis,

Delhoménie, M.-C., & Heitz, M. (2005). Biofiltration of Air: A Review. Critical Reviews in

Biotechnology, 25(1-2), 53–72.

Demeestere, K., Dewulf, J., Witte, B. De, & Langenhove, H. Van. (2007). Sample preparation for

the analysis of volatile organic compounds in air and water matrices, 1153, 130–144.

Derwent, R. G. (1995). Sources, distributions and fates of VOCs in the atmosphere. In Hester, R. E.,

Harrison, R. M. and Derwent, R. G. editors, Volatile organic compounds in the

atmospheres.

Devinny, J. S., and Hodge, D. S. (1995). Formation of acidic and toxic intermediates in

overloaded ethanol biofilters. Journal of the Air &Waste Management Association. 45(2):

125–131

Diks, R. M. M., and Ottengraf, S. P. P. (1991). Verification studies of a simplified model for the

removal of dichloromethane from waste gases using a biological trickling filter (Part I).

Bioprocess Engineering. 6(3): 93–99

Do, D. H., Langenhove, H. Van, Walgraeve, C., Hayleeyesus, F., Wispelaere, P. De, & Dewulf, J.

(2013). Volatile organic compounds in an urban environment : a comparison among

Belgium , Vietnam and Ethiopia, 7319

Douglas Hodge and Joseph S. Devinny (1997). Determination of transfer rate constants and

partitioning coefficients for air phase biofilters. J. Environ. Eng. 123(6):577-585

Dumanoglu, Y., Kara, M., Altiok, H., Odabasi, M., & Elbir, T. (2014). Spatial and seasonal variation

and source apportionment of volatile organic compounds (VOCs ) in a heavily

industrialized region. Atmospheric Environment, 98, 168–178.

E.J. Calabrese and E.M. Kenyon.(1991. Air Toxics and Risk Assessment. Lewis Publishers, Chelsea,

MI.

Epa. (2009). Methane: Sources and Emissions. U.S. Environmental Protection Agency (EPA).

Retrieved from http://www.epa.gov/outreach/sources.html

European Commission (2003). IPPC Reference document on Best Available Techniques in

common waste water and waste gas treatment/management systems in the chemical

sector, Sevilla, Spain.

Page 71: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

61

European Environment Agency (2010). European Union emission inventory report 1990–2008

under the UNECE Convention on Long-range Transboundary Air Pollution (LRTAP). EEA

Technical report 7/2010, ISBN 978-92-9213-102-9, Copenhagen, Denmark.

European Pollutant Release and Transfer Register (2016). Available from

http://prtr.ec.europa.eu/

Evuti, A. M. (2013). A Synopsis on Biogenic and Anthropogenic Volatile Organic Compounds

Emissions: Hazards and Control. International Journal of Engineering Sciences, 2(5)(May),

145–153.

Fellin P, Otson R (1994). Assessment of the influence of climatic factors on concentration levels of

volatile organic compounds (VOCs) in Canadian homes. Atmos Environ 1994; 28:3581-6

Felzer, B. S., Cronin, T., Reilly, J. M., Melillo, J. M., & Wang, X. (2007). Impacts of ozone on trees

and crops. Comptes Rendus - Geoscience, 339(11-12), 784–798.

Fiore, A. M., Naik, V., Spracklen, D. V., Steiner, A., Unger, N., Prather, M., Bergmann, D., Cameron-

Smith, P. J., Cionni, I., Collins,W. J., Dalsoren, S., Eyring, V., Folberth, G. A., Ginoux, P.,

Horowitz, L. W., Josse, B., Lamarque, J.-F., MacKenzie, I. A., Nagashima, T., O’Connor, F. M.,

Righi, M., Rumbold, S. T., Shindell, D. T., Skeie, R. B., Sudo, K., Szopa, S., Takemura, T., and

Zeng, G. (2012). Global air quality and climate, Chem. Soc. Rev., 41, 6663–6683,

Font, X., Artola, A. and Sanchez, A .(2011). Detection, composition and Treatment of Volatile

Organic Compounds from Waste Treatment Plants. Sensors. 11, 4043-4059.

García-Peña EI, Hernández S, Favela-Torres E, Auria R, Revah S. (2001). Toluene biofiltration by

the fungus Scedosporium apiospermum TB1. Biotechnol Bioeng 76:61–69

Gerhartz, W. (1990.). Ullmann's Encyclopedia of Industrial Chemistry. 5th ed.Vol A1: Deerfield

Beach, FL: VCH Publishers, p. VB1 5-10

Goldstein, A. H., and Galbally, I. E. (2007). Known and unexplored organic Constituents in the

earth’s atmosphere. Journal of environmental Science and technology. 1515-1521

GoR. (2012). 2012 Population and Housing Census .Report on Provincial Results. National Institute

of Statistics of Rwanda, (November), 1–50.

Gracy, S., Hort, C., Platel, V., & Gidas, M. B. (2006). Volatile Organic Compounds (VOCs)

biofiltration with two packing materials. Environmental Technology, 27(9), 1053–61.

Guenther, A., Hewitt, C. N., Erickson, D., Fall, R., Geron, C., Graedel, T., Harley, P., Klinger, L.,

Lerdau, M., McKay, W. A., Pierce, T., Scholes, B., Steinbrecher, R., Tallamraju, R., Taylor, J.,

and Zimmerman, P (1995). A global model of natural volatile organic compound

emissions, J. Geophys. Res., 100, 8873–8892.

Hansch C, Leo A, D. Hoekman.(1995). Exploring QSAR-Hydrophobic, Electronic and Steric

Constants, Washington, DC: American Chemical Society: p.6

Page 72: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

62

Haynes, W.M. (2011) CRC Handbook of Chemistry and Physics. 91st ed. Boca Raton, FL: CRC

Press Inc., 2010-2011, p. 3-282

Hazardous substance database bank (HSDB), (2015), HSDB: Acetone, Retrieved on: 07/12/2015.

https://www.nlm.nih.gov/pubs/factsheets/hsdbfs.html

Heroux M-E, Gauvin D, Gilbert NL, Guay M, Dupuis G, Legris M, et al. (2008) Housing

characteristics and indoor concentrations of selected volatile organic compounds

(VOCs) in Quebec City, Canada. Indoor Built Environ 17(2):128-37.

Hoai, D., Walgraeve, C., Nuguse, A., Rani, K., Estigoy, A., Demeestere, K., & Langenhove, H. Van.

(2015). Airborne volatile organic compounds in urban and industrial locations in four

developing countries. Atmospheric Environment, 119, 330–338.

Hodge, S. D. and J. S. D. (2010). Determination of transfer rate constants and partition

coefficients for air phase biofilters, 123(June), 3069.

Hong, J. H., Park, K. J. (2004). Wood chip biofilter performance of ammonia gas from composting

manure. Compost Science and Utilization. 12(1): 25–30.

ILO-ICSC (2015). Dimethyl sulfide. Retrieved on 08/12/2015

L: http://www.ilo.org/dyn/icsc/showcard.display?p_card_id=0878

J.M. Estrada, N.J.R.B. Kraakman, R. Muñoz and R. Lebrero (2011). Environ. Sci. Technol. 45, 1100

doi:10.1021/es103478j.

Jiang C., Mohamed A. H., Stark R. H., Yuan J. H. and Schoenbach K. H.(2005). Removal of

Volatile Organic Compounds in Atmospheric Pressure Air by means of Direct Current

Glow Discharges. IEEE transaction on plasma science: 33(4).

Jimenez, J. L., Canagaratna, M. R., Donahue, N. M., Prevot, A. S. H., Zhang, Q., Kroll, J. H.,

DeCarlo, P. F., Allan, J. D., Coe, H., Ng, N. L., Aiken, A. C., Docherty, K. S., Ulbrich, I. M.,

Grieshop, A. P., Robinson, A. L., Duplissy, J., Smith, J. D.,Wil- son, K. R., Lanz, V. A., Hueglin,

C., Sun, Y. L., Tian, J., Laak- sonen, A., Raatikainen, T., Rautiainen, J., Vaattovaara, P., Ehn,

M., Kulmala, M., Tomlinson, J. M., Collins, D. R., Cubison, M. J., E., Dunlea, J., Huffman, J.

A., Onasch, T. B., Alfarra, M. R., Williams, P. I., Bower, K., Kondo, Y., Schneider, J., Drewnick,

F., Borrmann, S., Weimer, S., Demerjian, K., Salcedo, D., Cottrell, L., Griffin, R., Takami, A.,

Miyoshi, T., Hatakeyama, S., Shimono, A., Sun, J. Y., Zhang, Y. M., Dzepina, K., Kimmel, J.

R., Sueper, D., Jayne, J. T., Herndon, S. C., Trimborn, A. M., Williams, L. R., Wood, E. C.,

Middlebrook, A. M., Kolb, C. E., Baltensperger, U., and Worsnop, D. R. (2009): Evolution of

Organic Aerosols in the Atmosphere, Science, 326, 1525–1529,

doi:10.1126/science.1180353,

Kanakidou, M., Seinfeld, J. H., Pandis, S. N., Barnes, I., Dentener, F. J., Facchini,

M. C.,Van Dingenen, R., Ervens, B., Nenes, A., Nielsen, C. J., Swietlicki, E., Putaud, J. P.,

Page 73: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

63

Balkanski, Y., Fuzzi, S., Horth, J., Moortgat, G. K., Winterhalter, R., Myhre, C. E. L., Tsigaridis,

K., Vignati, E., Stephanou, E. G., and Wilson, J.( 2005). Organic aerosol and global climate

modelling: a review, Atmos. Chem. Phys., 5, 1053–1123, doi:10.5194/acp-5-1053-2005,

Kavouras, I. G., Mihalopoulos, N., and Stephanou, E. G.(1998) Formation of atmospheric particles

from organic acids produced by forests, Nature, 395, 683–686, doi: 10.1038/27179.

Kennes, C., & Veiga, M. C. (2010). Technologies for the abatement of odours and volatile

organic and inorganic compounds. Chemical Engineering Transactions, 23, 1–6.

Kennes, C., and Thalasso, F. (1998). Waste gas biotreatment technology. Journal of Chemical

Technology & Biotechnology. 72(4): 303– 319

Kesselmeier, J., & Staudt, M. (1999). Biogenic Volatile Organic Compounds (VOC)

An Overview on Emission , Physiology, and Ecology, 23–88.

Kibazohi O, Yun S, Anderson WA. (2004). Removal of hexane in biofilters packed with perlite and

a peat-perlite mixture. World J Microb Biot 20:337–343

Kibazohi, O., Yun, S. Il, & Anderson, W. A. (2004). Removal of hexane in biofilters packed with

perlite and a peat-perlite mixture. World Journal of Microbiology and Biotechnology,

20(4),

Kumar, T., Rahul, M., & Chandrajit, B. (2011). Biofiltration of volatile organic compounds (VOCs):

An overview. Research Journal of Chemical Sciences, 1(8), 83–92.

Laurenzis, A., Heits, H., W¨ubker, S. M., Heinze, U., Friedrich, C., and Werner, U. (1998). Continuous

biological waste gas treatment in a stirred trickle-bed reactor with the discontinuous

removal of biomass. Biotechnology & Bioengineering. 57(4): 497–503

Leson, G. (1998). Biofilters in practice. In: Bioremediation. pp. 523–556. Vol. 3. Sidkar, S.K., Irvine,

R.L., Eds. Techonomic Publishing. Lancaster

Leson, G., and Winer, A.M. (1991). Biofiltration: An innovative air pollution control technology for

VOC emissions. Journal of the Air & Waste Management Association. 41(8): 1045–1054

Lewis, R.J. Sr. Hawley’s (2001). Condensed Chemical Dictionary 14th Edition, John Wiley & Sons,

Inc, New York, NY,.p.8

Lewis, R.J. Sr. Hawley’s (2007). Condensed Chemical Dictionary 15th Edition, John Wiley & Sons,

Inc, New York, NY,.p.454

Lide, D.R. CRC. (2005). Handbook of Chemistry and Physics 86th Edition 2005-2006. CRC Press,

Taylor and Francis, Boca Raton, FL, p.3-4

Lide, D.R. CRC (2007). Handbook of Chemistry and Physics 88th Edition 2007-2008. CRC Press,

Taylor and Francis, Boca Raton, FL, p.3-210

Page 74: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

64

Lin, T.Y., Sre, U., Tseng, S.H., Chiu, K.H., Wu, C.H., Lo, J.G. (2004). Volatile organic compound

concentrations in ambient air of Kaohsiung petroleum refinery in Taiwan. Atmos. Environ.

38, 4111-4122.

Liu Y, Shao M, Fu L, Lu S, Zeng L, Tang D. (2008). Source profiles of volatile organic compounds

(VOCs) measured in China: part I. Atmos Environ 42: 6247-60.

Logan, J.A., (1994). Trends in the vertical distribution of ozone: An analysis of ozonesonde data.

Journal of Geophysical Research 99, 25553-25585.

Loy, J., Heinrich, K., and Egerer, B. (1997). Influence of filter bed material on the elimination rate

in a biotrickling filter bed. In: Proceedings of the 90th Annual Meeting & Exhibition of the

Air &Waste Management Association. June 8–13, 1997. Toronto. Air & Waste

Management Association,

Lu, C., Chu,W., and Lin, M.-R. (2000). Removal of BTEX vapor from waste gases by a trickle bed

biofilter. Journal of the Air &Waste Management Association. 50(3): 411–417.

M. Caselli, G.d.e. Gennaro, M.R. Saracino, and M. Tutino (2009). Environ. Res. 109, 149

M. Sittig.( 1985). Handbook of Toxic and Hazardous Chemicals and Carcinogens. 2nd ed. Noyes

Publications, Park Ridge, NJ.

Madjid Mohseni Tonekaboni (1998). Biofiitration of Hydrophilic and Hydrophobic volatile organic

compounds using wood based media. National library of Canada, Canada.

McAuliffe C; J Phys Chem 70: 1267-75 (1966)

MINECOFIN. (2013). The Republic of Rwanda ECONOMIC DEVELOPMENT AND POVERTY

REDUCTION STRATEGY , (September 2007), 2008–2012.

Mohammed Y.S, Mokhtar A.S., Bashir N., Abdullahi .U., Kaku S.J., U. U. (2012). A Synopsis on the

Effects of Anthropogenic Greenhouse Gases Emissions from Power Generation and

Energy, 2(10), 1–6.

Monks, P. S., Archibald, A. T., Colette, A., Cooper, O., Coyle, M., Derwent, R., … Granier, C.

(2015). Tropospheric ozone and its precursors from the urban to the global scale from air

quality to short-lived climate forcer, 8889–8973.

Morales M, Revah S, Auria R (1998). Start-up and effect of gaseous ammonia additions on a

biofilter for the elimina- tion of toluene vapors. Biotechnol Bioeng 60:483–491

Müller J.-F. (1992). Geographical distribution and seasonal variation of surface emissions and

deposition velocities of atmospheric trace gases. J. Geophys. Res. 97(D4), 3787–3804.

Myhre, G., Shindell, D., Bréon, F.-M., Collins, W., Fuglestvedt, J., Huang, J., … Zhan, H. (2013).

Anthropogenic and Natural Radiative Forcing. Climate Change 2013: The Physical

Science Basis. The contribution of Working Group I to the Fifth Assessment Report of the

Intergovernmental Panel on Climate Change, 659–740.

Page 75: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

65

Nanda S, Sarangi PK, Abraham J (2012). Microbial biofiltration technology for odor abatement:

an introductory review. J Soil Sci Environ Manage 3:28–35.

Nature), Atmos. Chem. Phys., 6, 3181–3210, doi: 10.5194/acp-6- 3181-2006, 2006

NIOSH (2015). NIOSH Pocket Guide to Chemical Hazards. Department of Health & Human

Services, Centers for Disease Control & Prevention. National Institute for Occupational

Safety & Health. DHHS (NIOSH) Publication No. 2010-168. Retrieved on 08-12-2015 from:

http://www.cdc.gov/niosh/npg

O’Dowd, C. D., Aalto, P., Hmeri, K., Kulmala, M., and Hoffmann, T. (2002). Aerosol formation:

Atmospheric particles from organic vapours, Nature, 416, 497–498, doi: 10.1038/416497a,.

O’Neil, M.J. (2001) An Encyclopedia of Chemicals, Drugs, and Biologicals 13th Edition,

Whitehouse station, NJ: Merck and Co., Inc. p.13

Oh, Y. S., and Bartha, R. (1997). Removal of nitrobenzene vapors by a trick- ling air biofilter.

Journal of Industrial Microbiology & Biotechnology. 18(5): 293–296

O'Neil, M.J. (2006). The Merck Index - An Encyclopedia of Chemicals, Drugs, and Biologicals.

Whitehouse Station, NJ: Merck and Co., Inc p. 811

Ottengraf SPP (1987). Biological Systems for Waste Gas Elimination. Trends Biotechnol 5:132–136.

Paca J, Koutsky B, Maryska M, Halecky M. (2001). Styrene degradation along the bed height of

perlite biofilter. J Chem Technol Biotechnol 76:873–878.

Pubchem (2015). Dimethyl Sulfide. Retrieved on 07/12/2015

http://cameochemicals.noaa.gov/chemical/590

R. Iranpour, H.H.J. Cox, M.A. Deshusses and E.D. Schroeder (2005). Environ. Prog. 24, 254.

doi:10.1002/ep.10077.

Rudnicka, J., Walczak, M., Kowalkowski, T., Jezierski, T., & Buszewski, B. (2014). Sensors and

Actuators B : Chemical Determination of volatile organic compounds as potential

markers of lung cancer by gas chromatography – mass spectrometry versus trained

dogs. Sensors & Actuators: B. Chemical, 202, 615–621.

S.O. Baek, Y.S. Kim, and R. Perry (1997) Atmos. Environ. 31, 529.

Salthammer, T. (2011). Chemosphere Critical evaluation of approaches in setting indoor air

quality guidelines and reference values. Chemosphere, 82(11), 1507–1517.

Sanchez, M., Karnae, S., & John, K. (2008). Source Characterization of Volatile Organic

Compounds Affecting the Air Quality in a Coastal Urban Area of South Texas, 5(3),

130–138.

Schönduve, P., Sara, M. and Friedl, A. (1996). Influence of physiologically relevant parameters on

biomass formation in a trickle-bed bioreactor used for waste gas cleaning. Applied

Microbiology & Biotechnology. 45(1–2): 286–292.

Page 76: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

66

Schwartz, S.E., (1989). Acid deposition: unraveling a regional phenomenon.Science 243, 753-763.

Scott, C. E., Rap, A., Spracklen, D. V., Forster, P. M., Carslaw, K. S., Mann, G. W., Tunved, P. (2014).

The direct and indirect radiative effects of biogenic secondary organic aerosol.

Atmospheric Chemistry and Physics, 14(1), 447–470.

Scott, C. E., Spracklen, D. V., Pierce, J. R., Riipinen, I., D’Andrea, S. D., Rap, a., Pringle, K. J.

(2015). The impact of gas-to-particle partitioning approaches on the simulated radiative

effects of biogenic secondary organic aerosol. Atmospheric Chemistry and Physics

Discussions, 15(4), 4145–4172.

Scriban, R. (1993). Biotechnologie. 4th edition. Tec & Doc Lavoisier. Paris

Smet, E., Chasaya, G., van Langenhove, H., and Verstraete,W. (1996a). The effect of inoculation

and the type of carrier material used on the biofiltration of methyl sulphides. Applied

Microbiology & Biotechnology. 45(1–2): 293–298.

Smet, E., van Langenhove, H., and Verstraete, W. (1996b). Longterm stability of a biofilter treating

dimethyl sulphide. Applied Microbiology & Biotechnology. 46(2): 191–196.

Smith, D. and P. Španel, selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas

analysis, Mass Spectrometry Reviews 24, 661–700, 2005.

Smith, F. L., Sorial, G. A., Suidan, M. T., Breen, A. W., Biswas, P., and Brenner, R. C. (1996).

Development of two biomass control strategies for extended, stable operation of highly

efficient biofilters with high toluene loadings. Environmental Science & Technology. 30(5):

1744–1751

Sorial, G. A., Smith, E. L., Biswas, P., and Brenner, R. C. (1995). Evaluation of trickle-bed biofilter

media for toluene removal. Journal of the Air &Waste Management Association. 45(10):

801–810.

Španel, P. and D. Smith (2011). Progress in SIFT-MS: breath analysis and other applications, Mass

Spectrometry Reviews 30, 236–267.

Španěl, P., & Smith, D. (2001). Quantitative selected ion flow tube mass spectrometry: The

influence of ionic diffusion and mass discrimination. Journal of the American Society for

Mass Spectrometry, 12(7), 863–872.

Spengler JD (1995). Indoor air quality innovation and technology in Morawska L, Bofinger ND,

Maroni M, editors. Indoor air: an integrated approach. 1st ed. Oxford: Elsevier Science Lt;

1995. p. 33

Spesyvyi, A. (2012). Ion Trajectories in the Injection Quadrupole for SIFT-MS, 44–48.

Spigno G, Pagella C, Fumi MD, Molteni R, De Faveri DM. (2003). VOCs removal from waste gases:

gas phase bioreactor for the abatement of hexane by Aspergillus níger. Chem Eng Sci

58:739–746.

Page 77: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

67

Stocco C, MacNeill M, Wang D, Xu X, Guay M, Brook J, et al. (2008). Predicting personal

exposure of Windsor, Ontario residents to volatile organic compounds using indoor

measurements and survey data. Atmos Environ; 42:5905-12.

Stoji, A., Maleti, D., Stani, S., Miji, Z., & Andrej, Š. (2015). The science of the Total Environment

Forecasting of VOC emissions from traffic and industry using classification and regression

multivariate methods, 522, 19–26.

Stranger, M., Potgieter-Vermaak, S. S., & Van Grieken, R. (2007). Comparative overview of indoor

air quality in Antwerp, Belgium. Environment International, 33(6), 789–797.

Swanson,W. J., and Loehr, R. C. (1997). Biofiltration: fundamentals, design, and operations

principles, and applications. Journal of Environmental Engineering. 123(6): 538–546

T, S., & Reddy, K. K. S. K. (2011). Ozone Layer Depletion and Its Effects: A Review. International

Journal of Environmental Science and Development, 2(1), 30–37.

T.K. Ralebitso-Senior, E. Senior, R. Di Felice and K. Jarvis (2012). Environ. Sci. Technol. 46, 8542

U.S. Department of Health and Human Services (1993) Hazardous Substances Data Bank (HSDB,

online database). National Toxicology Information Program, National Library of Medicine,

Bethesda, MD.

U.S. Environmental Protection Agency (1999). ntegrated Risk Information System (IRIS) on n-

Hexane. National Center for Environmental Assessment, Office of Research and

Development, Washington, DC..

US-EPA (2015). Estimation Program Interface (EPI). Retrieved on 07/12/2015

http://www.epa.gov/oppt/exposure/pubs/episuitedl.htm

Vallero, D. (2008). Air Pollution, 3–7.

Verschueren, K. (2001). Handbook of environmental Data on organic chemicals. Volumes 1-2. 4th

ed John Wiley & Sons, New York, NY,.p.107

Verschueren, K. (2001). Handbook of Environmental Data on Organic Chemicals. Volumes 1-2.

4th ed. John Wiley & Sons. New York, NY., p. 1269

Viswanathan, B., Katsumata, H., Navaladian, S., & Janet, C. M. (2007). On the possible treatment

procedures for organic contaminants. Technology (Vol. 661).

Volckaert, D. (2014). Evaluation of conventional and innovative air treatment biotechnologies

for VOC mixtures. Journal of Chemical Information and Modeling (Vol. 53).

Walgraeve, C., Bruneel, J., Van Huffel, K., Demeestere, K., Vincze, L., De Meulenaer, B., & Van

Langenhove, H. (2015). Sorption behaviour of targeted volatile organic compounds on

airborne particulate matter using selected ion flow tube mass spectrometry. Biosystems

Engineering, 131(0), 84–94.

Page 78: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

68

Wallace LA, Pellizzari E, Leaderer B, Zelon H, Sheldon L. (1987). Emissions of volatile organic

compounds from building materials and consumer products. Atmos Environ; 21:385-93.

Watson JG, Chow JC, Fujita EM. (2001). Review of volatile organic compound source

apportionment by chemical mass balance. Atmos Environ 35:1567-84.

Wheeler AJ, Wong SL, Khoury C, Zhu J. (2013). Predictors of indoor BTEX concentrations in

Canadian residences. Health Rep; 24:11-7.

World Bank, (2016). Population density (people per sq. km of land area) retrieved on 05-05-2016:

http://data.worldbank.org/indicator/EN.POP.DNST

World Health Organization (2014). The burden of disease from the joint effects of Household and

Ambient Air Pollution for 2012, (2003), 2012–2014.

WÜbker, S.-M., Laurenzis, A., Werner, U., and Friedrich, C. (1997). Con- trolled biomass formation

and kinetics of toluene degradation in a bioscrubber and in a reactor with a periodically

moved trickle-bed. Biotechnology & Bioengineering. 55(4): 686–692

Y. Andres, E. Dumont, P. Le Cloirec and E. Ramirez-Lopez (2006). Environ. Technol. 27, 1297

doi:10.1080/09593332708618747.

Yamashita, S., and Kitagawa, M. (1998). Removal of toluene and benzene from flue gas by a

biotrickling filtration system which uses a urethane foam filter. In: Proceedings of the 91st

Annual Meeting & Exhibition of the Air &Waste Management Association. June 14–18,

1998. San Diego. Air & Waste Management Association, Pittsburgh.

Yang H, Minuth B, Allen DG (2002). Effects of nitrogen and oxygen on biofilter performance. J Air

Waste Manag Assoc 52:279–286

Ye W, Little JC, Won D, Zhang X. (2014). Screening-level estimates of indoor exposure to volatile

organic compounds emitted from building materials. Build Environ; 75:58-66

Zhu J, Newhook R, Marro L, Chan CC. (2005). Selected volatile organic compounds in the

residential air in the city of Ottawa, Canada. Environ Sci Technol; 39: 3964-71.

Page 79: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

69

APPENDIX I

78 standard VOCs used for calibration of the TD-GC-MS are shown together with their

characterizing ions, the load mass, the retention time, relative peak area and RSRF toluene d8.

Compound Ion Mass Retention time RSRF RPA

(ng) (min)

Alkanes

hexane 41,71,86 32.95 5.88 1.27 0.87

heptane 70,71,100 34.20 12.64 0.26 0.19

octane 71,85,114 35.15 22.33 0.26 0.19

nonane 57,85,128 35.90 28.28 0.43 0.33

decane 75,85,142 36.50 31.71 0.12 0.10

undecane 57,85,156 37.00 34.36 0.51 0.40

dodecane 57,85,170 37.65 36.61 0.53 0.42

2-methyl pentane 43,57,71 32.65 4.74 0.14 0.10

cycloalkanes

methylcyclopentane 55,56,69,84 37.45 7.23 0.04 0.03

cyclohexanes 41,55,56,69,84 38.95 9.32 0.08 0.07

Alkenes

1-pentene 55,70 32.00

1-hexene 84,15 39.90 5.43 0.02 0.02

Aromatic hydrocarbons

Benzene 52,63,77,78 43.70 8.73 0.59 0.54

Toluene 65,91,92 43.30 17.89 0.99 0.91

Ethylbenzene 91,106 43.35 25.91 0.90 0.84

p-xylene 91,105,106 43.30 26.44 0.99 0.92

m-xylene 91,105,106 43.40 26.39 0.93 0.85

o-xylene 91,105,106 43.90 27.52 0.99 0.92

styrene 51,78,104 45.45 27.32 0.92 0.86

propylbenzene 9,192,120 43.10 30.02 1.07 0.98

1,2,4-trimethylbenzene 105,120 44.00 31.37 1.09 1.02

Phenol 65,66,94 53.50 30.68 0.45 0.51

1-bromo-4-fluorobenzene 75,95,174,176 79.65 28.59 0.69 1.20

Aldehydes

hexanal 44,56,72,82 40.75 20.26 0.25 0.22

heptanal 44,70,96 41.00 27.48 0.26 0.23

benzaldehyde 77,105,106 52.50 29.7 0.48 0.56

butanal 41,44,45,72 40.85 4.9 0.19 0.16

isobutylaldehyde 41,43,73 39.50 4.01 0.33 0.30

3-methylbutylaldehyde 41,42,43,58,71,86 39.80 7.75 0.23 0.20

Alcohols

Page 80: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

70

1-butanol 28,31,33,56 40.50 8.9 0.17 0.14

1-pentanol 29,31,55,57,70 40.55 20.65 0.15 0.13

2-ethyl-1-hexanol 31,56,70,83,112 41.55 32.23 0.23 0.21

1-octanol 68,69,70,83,84,112 41.35 33.31 0.30 0.27

3-methyl-1-butanol 29,31,42,70 40.00 15.00 0.21 0.18

isopropanol 29,31,45,59 39.25 2.93 0.41 0.34

2-methyl-1-propanol 31,33,43,74 40.15 6.77 0.19 0.16

Ketone

2-butanone 71,72,73 40.30 5.04 0.38 0.32

2-hexanone 43,71,85,100 40.60 19.35 0.35 0.30

2-heptanone 58,71,114 41.00 26.99 0.38 0.33

2-octanone 58,113,128 40.95 30.88 0.36 0.31

5-nonanone 85,100,142 41.00 33.31 0.36 0.32

5-methyl-3-heptanone 71,99,128 41.15 29.3 1.01 0.90

acetophenone 51,77,105,120 51.50 33.05 0.59 64

Esters

Ethylacetate 61,70,88 45.10 5.96 0.12 0.11

n-propylacetate 61,73 44.00 12.74 0.17 0.16

methylbenzoate 77,105,136 54.00 33.93 0.85 0.97

methylacetate 29,43,59,74 46.50 3.46 0.28 0.28

other oxyganated compounds

furan 39,68,69 46.80 3.04 0.20 0.20

2-methylfuran 53,81,82 45.50 5.7 0.26 0.25

tetrahydrofuran 41,71,72 44.45 6.69 0.27 0.25

Halogated compounds

Chloroform 47,83,85 74.60 6.11 0.23 0.37

carbon tetrachloride 117,119,121 79.70 9.11 0.13 0.22

dichloromethane 49,84,86 66.25 3.52 2.06 2.90

chlorobenzene 77,112,114 55.38 24.77 0.62 0.73

1,3-dichlorobenzene 75,111,146,148 64.40 31.64 0.82 1.12

1,2,4 trimethylbenzene 105,120 44.00 31.37 1.09 0.99

1,3,5 Triisopropylbenzene 161,189,204 42.70 38.82 1.03 0.94

1,1,2 trichloroethane 61,97,99,132 71.75 17.00 0.34 0.51

1,2-dichloroethane 62,64,98 62.65 7.32 0.11 0.15

1,2- dichloropropane 62,63,76 57.80 10.91 0.25 0.30

1,1,2-trichlorotrifluoroethane 101,103,151,153 78.50 3.70 0.12 0.07

trichloroethylene 95,97,130,132 73.00 11.66 0.53 0.83

tetrachloroethylene 131,164,166,168 81.15 22.37 0.48 0.83

1,2,4-trichlorobenzene 145,180,182,184 72.70 36.25 0.74 1.15

1,1,1,2-tetrachloroethane 95,117,119,161,133 79.90 24.80 0.46 0.78

Sulfur compounds

dimethyldisulfide 945,79,94 53.13 15.2 0.004 0.004

carbondisulfide 44,76 63.00 3.79 0.04 0.06

Page 81: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

71

dimethylsulfide 61,62 42.00 3.36 0.02 0.02

Nitrogen containing compounds

acetonitrile 39,40,41 39.30 2.59 0.41 0.35

benzonitrile 76,103 50.50 30.32 0.88 0.95

Silicon containing compounds

hexamethyldisiloxane 73,147,148,149 38.20 11.63 0.97 0.79

trimethoxymethylsilane 91,105,121 48.00 13.97 0.11 0.10

Terpene

α-pinene 92,93,121,136 42.90 29.66 0.69 0.64

limonene 68,93,107,121,136 43.50 34.11 0.75 0.67

linalool 71,93,121,136 43.50 34.11 0.44 0.40

Internal Standard

Toluene-d8 98,100 47.00 17.52 - -

Page 82: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

72

APPENDIX II

A. Breakthrough curves for dry silicon foam

Acetone DMS Hexane

B. Breakthrough curves for dry wood chips

Acetone DMS Hexane

0

0.2

0.4

0.6

0.8

1

1.2

0 50

No

rmal

ize

d c

on

cen

trat

ion

s (-

)

time( min)

Acetone

0

0.2

0.4

0.6

0.8

1

1.2

0 50

No

rmal

ise

d c

on

cen

trat

ion

(-)

Time (min)

0

0.2

0.4

0.6

0.8

1

1.2

0 50

No

rmal

ize

d c

on

cen

trat

ion

s (-

)

Time (min)

0

0.2

0.4

0.6

0.8

1

1.2

0 50

no

rmal

ize

d c

on

cen

trat

ion

s (-

)

Time(min)

0

0.2

0.4

0.6

0.8

1

1.2

0 20

no

rmal

ize

d c

on

cen

trat

ion

s (-

)

Time(min)

0

0.2

0.4

0.6

0.8

1

1.2

0 20

no

rmal

ize

d c

on

cen

trat

ion

s (-

)

Time(min)

Page 83: CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC COMPOUNDS ...lib.ugent.be/fulltxt/RUG01/002/275/077/RUG01-002275077_2016_000… · CHARACTERIZATION OF INDUSTRIAL VOLATILE ORGANIC

73

C. Breakthrough curves for dry compost

Acetone* DMS Hexane

* Equilibrium not obtained

D. Breakthrough curve of compost at normal and dry condition.

0

0.2

0.4

0.6

0.8

1

1.2

0 100 200

no

rmal

ize

d c

on

cen

trat

ion

s (-

)

Time (min)

0

0.2

0.4

0.6

0.8

1

1.2

0 200 400No

rmal

ize

d c

on

cen

trat

ion

s (-

) Time (min)

0

0.2

0.4

0.6

0.8

1

1.2

0 200 400

No

rmal

ize

d c

on

cen

trat

ion

s (-

)

Time (min)