chapter 2 ipm: pest detection and monitoring · 2019. 11. 13. · chapter 2 ipm: pest detection and...

28
2019

Upload: others

Post on 26-Feb-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

2019

Page 2: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

3 models for indoor fogging

6 Liter tank

Rugged and durable

Oil and water formulations

Page 3: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM
Page 4: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

Air pressure goes to the tank and nozzle in the green hoses

…tank is pressurized

Liquid goes from the tank to nozzle in the red hoses

Liquid hose

Air pressure

hose

Page 5: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

Circular air-stream pulls liquid from the nozzle and breaks it into small droplets

Vortex nozzle

Page 6: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

Push down + turn base of adjustment knob to move point to the Zero position

Turn adjustment knob to the right to Off / Closed position, do not make it tight

Page 7: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

Zero

Move point to groove (Zero) on the front of nozzle…

…then turn knob open…

Page 8: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

Zero setting

Re-adjust the knob to Zero with every use…

Page 9: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

1/4 - turn

32 microns

3/4 quarter turn

39 microns

[Spray droplets not visible]

Page 10: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

10% of droplets 14.5 µm or smaller

90% of droplets 53 µm or smallerVMD - 33 µm

Large % droplets 30-45 µm

Page 11: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

3/4 turn to full opento kill cockroaches

1/4 to 2 quarter turnsto kill house flies¼ turn

¾ turn

32 microns

39 microns

Page 12: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

30 to 35 micron droplets provide

best contact and kill of adult house flies

Takebayashi, Y. 1998. SP World No. 26: 3-7.

% M

ort

ali

ty

Droplet size

30

Page 13: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

1 quarter turn = 0.33 ounces

2 quarter turns = 0.75 ounces

Full open = 2.5 ounces

Page 14: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

Spray extends up to 8 feet from nozzle

Droplets are delivered beyond

8 feet

Page 15: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

1/2 turn of adjustment knob

1.5 minutes = 1 ounce

For every 1,000 cubic feet…treat for 1.5 min. to get 1 0unce / 1,000

Page 16: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

First this…Turn back to

Zero

…then this turn motor

Off

Page 17: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

Tank is pressurized and liquid will continue to flow to the open nozzle and drip into the hose …and then damage motor Hint: Open / close tank

cap to relieve pressure and liquid flow to the nozzle

Page 18: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

Models are available with a 18 inch hose

Page 19: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM
Page 20: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

Without the application hose

Flow rate and adjustable droplet size the same as the 2600 fogger

Page 21: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

Has a single-stage fan and produces large droplets (not ULV)

Page 22: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

Remove the bottom plate and use soap and water to clean and dry the small air filters

Page 23: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

Droplets from oil-based formulations fall to the ground and form a distinct ring

Operate fogger for periods of about 20-minutes

Page 24: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

Electric cords and application hoses on foggers can be damaged by careless handling

Electric cord pulled out of a B&G 2600 fogger

Page 25: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

Air filter should be cleaned regularly to keep dirt from entering the fan motor

Clogged filter on a B&G 2600 fogger

Page 26: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

Fan motor can be damaged by moisture, usually from placing the fogger on wet surfaces during operation

Page 27: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

Use a 3-prong extension cord and the proper gauge:

50 feet = 16 gauge100 feet = 14 gauge250 feet = 10 gauge

Page 28: Chapter 2 IPM: PEST DETECTION AND MONITORING · 2019. 11. 13. · Chapter 2 IPM: PEST DETECTION AND MONITORING Author: mcorfman Created Date: 7/24/2019 10:17:13 PM

2019