chainflex data cables
DESCRIPTION
The catalogue gives an overview and technical data of chainflex data cables. The high flexible data cables are suitable for high stressing and are also available as flame-retardant and oil-resistant cables. The data cables can be used for high speeds and accelerations. All Chainflex data cables are executed as shielded cables.For more information see http://www.igus.co.uk/wpck/default.aspx?PageNr=2203&CL=GB-en&c=gb&L=en&wt.mc_id=SCRUKTRANSCRIPT
CF240 PVC 10-12 -5/ +70 3 2 20 112
CF240.PUR PUR 10-12 -20/ +80 3 2 20 114
CF211 PVC 7,5 -5/ +70 5 3 50 116
CF113 PUR 10 -20/ +80 10 5 80 118
CF11 TPE 6,8 -35/ +100 10 6 100 120
CF112 PUR 10 -20/ +80 10 5 80 122
CF12 TPE 10 -35/ +100 10 6 100 124
CF THERMO PUR 12,5-15 -20/ +80 2 1 20
CF KOAX 1 TPE 10 -35/ +100 10 5 100 128
chainflex® type
Data cables – Stranded in layers
Data cables – Twisted pair
Data cables – Twisted pair/Pair shield
Data cables – Thermo (Chapter "Special cables" 256)
Data cables – Coax
*
111Dat
a ca
bles
Coa
xial
cab
les
chai
nfle
x®
cab
le
Jack
et
Shi
eld
Tem
per
atur
em
ove
dfr
om
/to
[°C
]
Ap
pro
vals
and
stan
dar
ds
Min
imum
ben
din
gra
diu
s, m
ove
d[f
acto
r x
d]
Oil-
resi
stan
t
Tors
ion
resi
stan
t
v m
ax. [
m/s
]un
sup
po
rted
v m
ax.[
m/s
] g
lidin
g
a m
ax. [
m/s
2 ]
Pag
e
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 110
Conductor Very finely stranded special cores of particularly high-flexdesign made of bare copper wires.
Core insulation Mechanically high-quality PP mixture.
Core stranding The individual cores are stranded in layers with short pitchlengths.
Core identification Colour code in accordance with DIN 47100.
Intermediate jacket Foil taping over the external layer.
Overall shield Extremely bending-resistant braiding made of tinned copperwires. Coverage approx. 70% linear, approx. 90% optical.
Outer jacket Low-adhesion, oil-resistant mixture on the basis of PVC, adap-ted to suit the requirements in energy chains® (following DIN VDE0281 Part 13). Colour: Silver gray (similar to RAL 7001)
T/R moved -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2.+5 °C to +70 °C for use in energy chains® with > 50.000 cycles. Minimum bending radius 10 x d with < 10 m travel distance,minimum bending radius 12 x d with ≥ 10 m travel distance.
T/R fixed -20 °C to +70 °C, minimum bending radius 5 x d
v max. 3 m/s, 2 m/sunsupported/glidinga max. 20 m/s2
Travel distance Freely suspended and gliding travel distances up to 50 m,Class 2
Nominal voltage 300/300 V (following DIN VDE 0245).
Testing voltage 1500 V
Oil Oil-resistant (following DIN EN 50363-4-1), Class 2.
Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1
Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).
PVC Data cable CF240 Class 4.2.2 (4 medium load requirements 2 travel distance up to 50 m 2 oil-resistant)
for medium load requirements PVC outer jacket shielded oil-resistant flame-retardant
113Imag
e ex
emp
lary
. eplan download, configurator www.igus.eu/en/CF240
UL/CSA Style 10493 and 2464, 300 V, 80 °C
NFPA Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)
CEI Following CEI 20-35
CE Following 2006/95/EG
Lead free Following 2011/55/EU (RoHS-II)
Clean room According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPAaccording to standard 14644-1.
Typical application area
for medium load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 °C especially for freely suspended and gliding travel distances up to 50 m Storage and retrieval units for high-bay warehouses, machining units/packaging machines, handling, indoor cranes
CF240.01.03 (3 x 0,14)C 4,5 16 35CF240.01.04 (4 x 0,14)C 5,0 18 38CF240.01.05 (5 x 0,14)C 5,5 20 42CF240.01.07 (7 x 0,14)C 6,0 25 51CF240.01.14 (14 x 0,14)C 7,0 42 76CF240.01.18 (18 x 0,14)C 8,0 48 90CF240.01.24 (24 x 0,14)C 9,5 60 113CF240.02.03 (3 x 0,25)C 5,5 21 40CF240.02.04 (4 x 0,25)C 5,5 24 48CF240.02.05 (5 x 0,25)C 6,0 27 52CF240.02.07 (7 x 0,25)C 7,0 35 66CF240.02.08 (8 x 0,25)C 7,5 40 74CF240.02.14 (14 x 0,25)C 8,0 57 100CF240.02.18 (18 x 0,25)C 9,0 71 122CF240.02.24 (24 x 0,25)C 11,0 92 174CF240.03.03 (3 x 0,34)C 5,5 24 45CF240.03.04 (4 x 0,34)C 6,0 28 51CF240.03.05 (5 x 0,34)C 6,5 32 58CF240.03.07 (7 x 0,34)C 7,0 43 75CF240.03.10 (10 x 0,34)C 8,5 55 110CF240.03.14 (14 x 0,34)C 8,5 71 116CF240.03.18 (18 x 0,34)C 10,0 87 140CF240.03.24 (24 x 0,34)C 12,0 115 203
Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core
Delivery programPart No.
Number of cores andconductor nominalcross section [mm2]
External diameterapprox. [mm]
Copperindex[kg/km]
Weight[kg/km]
CF240PVC
10-12 x d
CF240PVC
10-12 x d
... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu
950 types from stock no cutting costs ...(for up to 10 cuts of the same type)
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 112
Conductor Very finely stranded special cores of particularly high-flexdesign made of bare copper wires.
Core insulation Mechanically high-quality PP mixture.
Core stranding The individual cores are stranded in layers with short pitchlengths.
Core identification Colour code in accordance with DIN 47100
Intermediate jacket Foil taping over the external layer
Overall shield Extremely bending-resistant braiding made of tinned copperwires. Coverage approx. 70% linear, approx. 90% optical.
Outer jacket Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains®
(following DIN VDE 0282 Part 10). Colour: Silver gray (similar to RAL 7001)
T/R moved -20 °C to +80 °C, minimum bending radius 10 x d with < 10 m traveldistance, minimum bending radius 12 x d with ≥ 10 m travel distance
T/R fixed -40 °C to +80 °C, minimum bending radius 5 x d
v max. 3 m/s, 2 m/sunsupported/glidinga max. 20 m/s2
Travel distance Freely suspended and gliding travel distances up to 50 m,Class 2.
UV-resistant Medium
Nominal voltage 300/300 V (following DIN VDE 0245)
Testing voltage 1500 V
Oil Oil-resistant (following DIN EN 50363-10-2), Class 3.
Offshore MUD-resistant following NEK 606 – status 2009.
Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1
PUR Data cable CF240.PUR Class 5.2.3 (5 high load requirements 2 travel distance up to 50 m 3 oil-resistant)
for high load requirements PUR outer jacket shielded oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant
Imag
e ex
emp
lary
. eplan download, configurator www.igus.eu/en/CF240PUR
CF240.PUR.01.03(1) (3 x 0,14)C 5,5 16 35CF240.PUR.01.04 (4 x 0,14)C 6,0 18 38CF240.PUR.01.05(1) (5 x 0,14)C 6,5 20 43CF240.PUR.01.07(1) (7 x 0,14)C 7,0 25 52CF240.PUR.01.14 (14 x 0,14)C 8,0 42 77CF240.PUR.01.18(1) (18 x 0,14)C 8,5 48 92CF240.PUR.02.03 (3 x 0,25)C 6,0 21 40CF240.PUR.02.04 (4 x 0,25)C 6,0 24 44CF240.PUR.02.05 (5 x 0,25)C 6,5 27 49CF240.PUR.02.07 (7 x 0,25)C 7,0 35 63CF240.PUR.02.08 (8 x 0,25)C 7,5 40 69CF240.PUR.02.14 (14 x 0,25)C 8,0 57 100CF240.PUR.02.18 (18 x 0,25)C 9,0 71 119CF240.PUR.03.03(1) (3 x 0,34)C 6,0 24 46CF240.PUR.03.04 (4 x 0,34)C 6,5 28 52CF240.PUR.03.05(1) (5 x 0,34)C 7,0 32 58CF240.PUR.03.07 (7 x 0,34)C 8,0 43 82CF240.PUR.03.14(1) (14 x 0,34)C 9,5 71 123CF240.PUR.03.18(1) (18 x 0,34)C 10,0 88 152
(1) Delivery time upon inquiry.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core
Delivery programPart No.
Number of cores andconductor nominalcross section [mm2]
External diameterapprox. [mm]
Copperindex[kg/km]
Weight[kg/km]
115
CF240.PURPUR
10-12 x d
CF240.PURPUR
10-12 x d
... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu
950 types from stock no cutting costs ...(for up to 10 cuts of the same type)
Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).
Halogen-free Following EN 50267-2-1.
UL/CSA Style 10493 and 20233, 300 V, 80°C
NFPA Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)
CEI Following CEI 20-35
CE Following 2006/95/EG
Lead free Following 2011/55/EU (RoHS-II)
Clean room According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D,tested by IPA according to standard 14644-1
Typical application area
for high load requirements almost unlimited resistance to oil indoor and outdoor applications with average sun radiation especially for freely suspended and gliding travel distances up to 50 m Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick
handling, refrigerating sector
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 114
Conductor Very finely stranded special cores of particularly high-flexdesign made of bare copper wires.
Core insulation Mechanically high-quality PP mixture.
Core stranding 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths.
Core identification Colour code in accordance with DIN 47100.
Intermediate jacket Foil taping over the external layer.
Overall shield Extremely bending-resistant braiding made of tinned copperwires. Coverage approx. 70% linear, approx. 90% optical.
Outer jacket Low-adhesion, oil-resistant mixture on the basis of PVC, adap-ted to suit the requirements in energy chains® (following DIN VDE0281 Part 13). Colour: Silver gray (similar to RAL 7001)
T/R moved -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2. +5 °Cto +70 °C for use in energy chains® with > 50.000 cycles. Minimumbending radius 7,5 x d. Following an extensive series of tests, thebending radius of CF211 has been reduced from 10 x d to 7,5 x d.
T/R fixed -20 °C to +70 °C, minimum bending radius 5 x d
v max. 5 m/s, 3 m/sunsupported/glidinga max. 50 m/s2
Travel distance Freely suspended and gliding travel distances up to 100 m,Class 3
Nominal voltage 300/300 V (following DIN VDE 0245).
Testing voltage 1500 V
Oil Oil-resistant (following DIN EN 50363-4-1), Class 2.
Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1
Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).
UL/CSA Style 10493 and 2464, 300 V, 80 °C
PVC Data cable CF211 Class 5.3.2 (5 high load requirements 3 travel distance up to 100 m 2 oil-resistant)
for high load requirements PVC outer jacket shielded twisted-pair oil-resistant flame-retardant
Imag
e ex
emp
lary
. eplan download, configurator www.igus.eu/en/CF211
NFPA Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)
CEI Following CEI 20-35
CE Following 2006/95/EG
Lead free Following 2011/55/EU (RoHS-II)
Clean room According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPAaccording to standard 14644-1.
Typical application area
for high load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 °C especially for freely suspended and gliding travel distances up to 100 m Storage and retrieval units for high-bay warehouses, machining units/packaging machines, handling, indoor cranes
CF211.02.01.02 (1 x (2 x 0,25))C 5,0 16 35CF211.02.02.02(2) (2 x (2 x 0,25))C 5,5 28 60CF211.02.03.02 (3 x (2 x 0,25))C 7,0 37 73CF211.02.04.02 (4 x (2 x 0,25))C 8,0 44 85CF211.02.05.02 (5 x (2 x 0,25))C 8,5 51 97CF211.02.06.02 (6 x (2 x 0,25))C 9,5 58 110CF211.02.08.02 (8 x (2 x 0,25))C 11,5 75 160CF211.02.10.02 (10 x (2 x 0,25))C 13,0 93 195CF211.02.14.02 (14 x (2 x 0,25))C 13,5 109 205CF211.03.03.02 (3 x (2 x 0,34))C 8,0 37 79CF211.03.08.02 (8 x (2 x 0,34))C 12,0 98 202CF211.03.10.02(1) (10 x (2 x 0,34))C 12,0 118 254CF211.05.01.02 (1 x (2 x 0,5))C 5,5 23 50CF211.05.02.02(2) (2 x (2 x 0,5))C 8,5 44 80CF211.05.03.02 (3 x (2 x 0,5))C 9,0 57 100CF211.05.04.02 (4 x (2 x 0,5))C 9,5 68 120CF211.05.05.02 (5 x (2 x 0,5))C 11,0 80 145CF211.05.06.02 (6 x (2 x 0,5))C 12,5 99 185CF211.05.08.02 (8 x (2 x 0,5))C 14,5 124 230CF211.05.10.02 (10 x (2 x 0,5))C 16,0 175 320CF211.05.14.02 (14 x (2 x 0,5))C 17,0 187 335
(1) Delivery time upon inquiry.The chainflex® types marked with (2) are cables designed as a star-quad.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core
Delivery programPart No.
Number of cores andconductor nominalcross section [mm2]
External diameterapprox. [mm]
Copperindex[kg/km]
Weight[kg/km]
Delivery program Measuring system cablesPage 164, CF211 (PVC)Page 170, CF111.D (TPE)Page 180, CF11.D (TPE)
117
CF211PVC
7,5 x d
CF211PVC
7,5 x d
... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu
950 types from stock no cutting costs ...(for up to 10 cuts of the same type)
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 116
Conductor Very finely stranded special cores of particularly high-flex designmade of bare copper wires.
Core insulation Mechanically high-quality TPE mixture.
Core stranding 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths.
Core identification Colour code in accordance with DIN 47100
Intermediate jacket PUR mixture adapted to suit the requirements in energy chains®.
Overall shield Extremely bending-resistant braiding made of tinned copperwires. Coverage approx. 70% linear, approx. 90% optical.
Outer jacket Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains®
(following DIN VDE 0282 Part 10). Colour: Anthracite gray (similar to RAL 7016)
T/R moved -20 °C to +80 °C, minimum bending radius 10 x d
T/R fixed -40 °C to +80 °C, minimum bending radius 5 x d
v max. 10 m/s, 5 m/sunsupported/glidinga max. 80 m/s2
Travel distance Freely suspended and gliding travel distances up to 100 m,Class 3
UV-resistant High
Nominal voltage 300/300 V (following DIN VDE 0245).
Testing voltage 1500 V.Oil Oil-resistant (following DIN EN 50363-10-2), Class 3.
Offshore MUD-resistant following NEK 606 – status 2009.
Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1
PUR Data cable CF113 Class 6.3.3 (6 maximum load requirements 3 travel distance up to 100 m 3 oil-resistant)
for maximum load requirements PUR outer jacket shielded, twisted-pair oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant
Imag
e ex
emp
lary
. eplan download, configurator www.igus.eu/en/CF113
CF113.02.02.02(2) (2 x (2 x 0,25))C 8,0 31 86CF113.02.03.02 (3 x (2 x 0,25))C 8,5 40 96CF113.02.04.02 (4 x (2 x 0,25))C 9,0 45 107CF113.02.05.02 (5 x (2 x 0,25))C 9,5 56 125CF113.02.06.02 (6 x (2 x 0,25))C 10,0 62 137CF113.02.08.02 (8 x (2 x 0,25))C 11,5 81 176CF113.05.02.02(2) (2 x (2 x 0,5))C 10,0 50 127CF113.05.03.02(1) (3 x (2 x 0,5))C 10,5 62 142CF113.05.04.02 (4 x (2 x 0,5))C 11,0 70 162CF113.05.05.02(1) (5 x (2 x 0,5))C 11,5 84 185CF113.05.06.02 (6 x (2 x 0,5))C 12,5 95 207
(1) Delivery time upon inquiryThe chainflex® types marked with (2) are cables designed as a star-quad.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core * New in this catalog.
Delivery programPart No.
Number of cores andconductor nominalcross section [mm2]
External diameterapprox. [mm]
Copperindex[kg/km]
Weight[kg/km]
New*
Order example: CF113.02.06.02 – in your desired length (0,5 m steps)CF113 chainflex® series .02 Code nominal cross section .06 Number of pairs .02 Identification pairs
Please use www.chainflex.eu/en/CF113 for your online order.
Delivery time 24h or today.Delivery time means time until shipping of goods.
119
CF113PUR
10 x d
CF113PUR
10 x d
... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu
950 types from stock no cutting costs ...(for up to 10 cuts of the same type)
Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).
Halogen-free Following EN 50267-2-1.
UL/CSA Style 10493 and 20233, 300 V, 80°C
NFPA Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)
CEI Following CEI 20-35
CE Following 2006/95/EG
Lead free Following 2011/55/EU (RoHS-II)
Typical application area
for maximum load requirements almost unlimited resistance to oil indoor and outdoor applications with average sun radiation especially for freely suspended and gliding travel distances up to 100 m Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick
handling, refrigerating sector
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 118
Conductor Fine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).
Core insulation Mechanically high-quality TPE mixture.
Core stranding 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths.
Core identification Cores < 1,0 mm2: Colour code in accordance with DIN 47100Cores ≥ 1,0 mm2: Cores black with white numerals
Inner jacket TPE mixture adapted to suit the requirements in energy chains®.
Overall shield Extremely bending-resistant braiding made of tinned copperwires. Coverage approx. 70% linear, approx. 90% optical.
Outer jacket Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements inenergy chains®. Colour: Steel blue (similar to RAL 5011)
T/R moved -35 °C to +100 °C, minimum bending radius 6,8 x d. Following an extensive series of tests, the bending radius ofCF11 has been reduced from 10 x d to 6,8 x d.
T/R fixed -40 °C to +100 °C, minimum bending radius 5 x d
v max. 10 m/s, 6 m/sunsupported/glidinga max. 100 m/s2
Travel distance Freely suspended and gliding travel distances up to 400 mand more, Class 4
UV-resistant High
Nominal voltage 300/300 V (following DIN VDE 0245).
Testing voltage 1500 V
Oil Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (fol-lowing VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.
Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).
TPE Data cable CF11 Class 6.4.4 (6 maximum load requirements 4 travel distance up to 400 m and more 4 oil-resistant)
for maximum load requirements TPE outer jacket shielded twisted-pair oil-resistant, biooil-resistant PVC-free/halogen-free hydrolysis-resistant and microbe-resistant
Imag
e ex
emp
lary
. eplan download, configurator www.igus.eu/en/CF11
Halogen-free Following EN 50267-2-1.
CE Following 2006/95/EG
Lead free Following 2011/55/EU (RoHS-II)
Clean room According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPAaccording to standard 14644-1
Typical application area
for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m and more Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,
semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications
CF11.01.04.02 (4 x (2 x 0,14))C 7,0 28 64CF11.01.18.02 (18 x (2 x 0,14))C 14,0 86 164CF11.02.01.02 (1 x (2 x 0,25))C 6,0 17 38CF11.02.02.02(2) (2 x (2 x 0,25))C 6,5 25 52CF11.02.03.02 (3 x (2 x 0,25))C 8,0 34 60CF11.02.04.02 (4 x (2 x 0,25))C 9,0 44 80CF11.02.05.02 (5 x (2 x 0,25))C 9,0 55 100CF11.02.06.02 (6 x (2 x 0,25))C 10,0 66 127CF11.02.09.02 (9 x (2 x 0,25))C 12,5 92 198CF11.02.10.02 (10 x (2 x 0,25))C 13,0 99 200CF11.02.14.02 (14 x (2 x 0,25))C 13,5 120 238CF11.03.08.02 (8 x (2 x 0,34))C 12,5 90 154CF11.05.04.02 (4 x (2 x 0,5))C 10,0 91 108CF11.05.06.02 (6 x (2 x 0,5))C 11,5 95 190CF11.05.08.02 (8 x (2 x 0,5))C 14,0 131 250CF11.07.03.02 (3 x (2 x 0,75))C 11,0 77 131CF11.10.04.02 (4 x (2 x 1,0))C 12,0 121 180CF11.15.06.02 (6 x (2 x 1,5))C 17,0 242 419CF11.25.03.02 (3 x (2 x 2,5))C 16,5 210 410
The chainflex® types marked with (2) are cables designed as a star-quad.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core
Delivery programPart No.
Number of cores andconductor nominalcross section [mm2]
External diameterapprox. [mm]
Copperindex[kg/km]
Weight[kg/km]
Delivery program Measuring system cablesPage 164, CF211 (PVC)Page 170, CF111.D (TPE)Page 180, CF11.D (TPE)
121
CF11TPE
6,8 x d
CF11TPE
6,8 x d
... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu
950 types from stock no cutting costs ...(for up to 10 cuts of the same type)
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 120
Conductor Very finely stranded special cores of particularly high-flex designmade of bare copper wires.
Core insulation Mechanically high-quality TPE mixture.
Core stranding 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths.
Core identification Colour code in accordance with DIN 47100
Element shield Extremely bending-resistant braiding made of tinned copperwires. Coverage approx. 70% linear, approx. 90% optical.
Intermediate jacket PUR mixture adapted to suit the requirements in energy chains®.
Overall shield Extremely bending-resistant braiding made of tinned copperwires. Coverage approx. 70% linear, approx. 90% optical.
Outer jacket Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains®
(following DIN VDE 0282 Part 10). Colour: Anthracite gray (similar to RAL 7016)
T/R moved -20 °C to +80 °C, minimum bending radius 10 x d
T/R fixed -40 °C to +80 °C, minimum bending radius 5 x d
v max. unsupported/gliding 10 m/s, 5 m/sa max. 80 m/s2
Travel distance Freely suspended and gliding travel distances up to 100 m,Class 3
UV-resistant High
Nominal voltage 300/300 V (following DIN VDE 0245).
Testing voltage 1500 V
Oil Oil-resistant (following DIN EN 50363-10-2), Class 3.
Offshore MUD-resistant following NEK 606 – status 2009.
PUR Data cable CF112 Class 6.3.3 (6 maximum load requirements 3 travel distance up to 100 m 3 oil-resistant)
for maximum load requirements PUR outer jacket double-shielded, twisted-pair oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant
Imag
e ex
emp
lary
. eplan download, configurator www.igus.eu/en/CF112
CF112.02.02.02 (2 x (2 x 0,25)C)C 9,5 54 125CF112.02.03.02(1) (3 x (2 x 0,25)C)C 10,0 68 144CF112.02.04.02 (4 x (2 x 0,25)C)C 11,0 78 159CF112.02.05.02(1) (5 x (2 x 0,25)C)C 11,5 95 184CF112.02.06.02(1) (6 x (2 x 0,25)C)C 12,0 107 210CF112.05.02.02(1) (2 x (2 x 0,5)C)C 11,5 72 168CF112.05.03.02(1) (3 x (2 x 0,5)C)C 12,0 95 192CF112.05.04.02 (4 x (2 x 0,5)C)C 12,5 113 221CF112.05.05.02(1) (5 x (2 x 0,5)C)C 13,5 137 263CF112.05.06.02 (6 x (2 x 0,5)C)C 14,5 155 307
(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core
Delivery programPart No.
Number of cores andconductor nominalcross section [mm2]
External diameterapprox. [mm]
Copperindex[kg/km]
Weight[kg/km]
Order example: CF112.02.04.02 – in your desired length (0,5 m steps)CF112 chainflex® series .02 Code nominal cross section .04 Number of pairs .02 Identification pairs
Please use www.chainflex.eu/en/CF112 for your online order.
Delivery time 24h or today.Delivery time means time until shipping of goods.
123
CF112PUR
10 x d
CF112PUR
10 x d
... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu
950 types from stock no cutting costs ...(for up to 10 cuts of the same type)
Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1
Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).
Halogen-free Following EN 50267-2-1.
UL/CSA Style 10493 and 20233, 300 V, 80°C
NFPA Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)
CEI Following CEI 20-35
CE Following 2006/95/EG
Lead free Following 2011/55/EU (RoHS-II)
Typical application area
for maximum load requirements almost unlimited resistance to oil indoor and outdoor applications with average sun radiation especially for freely suspended and gliding travel distances up to 100 m Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick
handling, refrigerating sector
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 122
Conductor Fine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).
Core insulation Mechanically high-quality TPE mixture.
Core stranding 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths.
Core identification Cores < 0,5 mm2: Colour code in accordance with DIN 47100Cores ≥ 0,5 mm2: Cores black with white numerals
Element shield Extremely bending-resistant braiding made of tinned copperwires. Coverage approx. 70% linear, approx. 90% optical.
Element jacket TPE mixture adapted to suit the requirements in energy chains®
over pair shield.Inner jacket TPE mixture adapted to suit the requirements in energy chains®.
Overall shield Highly flexible shield consisting of galvanized steel wire braid. Coverage approx. 70% linear, approx. 90% optical.
Outer jacket Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements inenergy chains®. Colour: Steel blue (similar to RAL 5011)
T/R moved -35 °C to +100 °C, minimum bending radius 10 x d
T/R fixed -40 °C to +100 °C, minimum bending radius 5 x d
v max. unsupported/gliding 10 m/s, 6 m/sa max. 100 m/s2
Travel distance Freely suspended and gliding travel distances up to 400 m,Class 4
UV-resistant High
Nominal voltage 300/300 V (following DIN VDE 0245).
Testing voltage 1500 V
Oil Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (fol-lowing VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.
TPE Data cable CF12 Class 6.4.4 (6 maximum load requirements 4 travel distance up to 400 m 4 oil-resistant)
for maximum load requirements TPE outer jacket double-shielded oil-resistant biooil-resistant PVC-free/halogen-free hydrolysis-resistant and microbe-resistant
Imag
e ex
emp
lary
. eplan download, configurator www.igus.eu/en/CF12
Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).
Halogen-free Following EN 50267-2-1.
CE Following 2006/95/EG
Lead free Following 2011/55/EU (RoHS-II)
Clean room According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPAaccording to standard 14644-1
Typical application area
for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,
semiconductor insertion, outdoor cranes, low-temperature applications, for especially high EMC safety
CF12.02.02.02 (2 x (2 x 0,25)C)C 11,0 27 152CF12.02.03.02(1) (3 x (2 x 0,25)C)C 11,5 40 172CF12.02.04.02 (4 x (2 x 0,25)C)C 11,5 61 179CF12.02.05.02 (5 x (2 x 0,25)C)C 13,0 93 220CF12.05.03.02 (3 x (2 x 0,5)C)C 13,0 66 210CF12.05.04.02 (4 x (2 x 0,5)C)C 14,0 88 255CF12.05.05.02 (5 x (2 x 0,5)C)C 15,5 110 297CF12.05.06.02 (6 x (2 x 0,5)C)C 17,0 132 360CF12.05.08.02 (8 x (2 x 0,5)C)C 20,0 177 477CF12.05.10.02 (10 x (2 x 0,5)C)C 23,0 221 548CF12.05.14.02 (14 x (2 x 0,5)C)C 23,0 309 723CF12.10.06.02 (6 x (2 x 1,0)C)C 20,0 198 542
(1) Delivery time upon inquiry.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core
Delivery programPart No.
Number of cores andconductor nominalcross section [mm2]
External diameterapprox. [mm]
Copperindex[kg/km]
Weight[kg/km]
Order example: CF12.02.03.02 – in your desired length (0,5 m steps)CF12 chainflex® series .02 Code nominal cross section .03 Number of pairs .02 Identification pairs
Please use www.chainflex.eu/en/CF12 for your online order.
Delivery time 24h or today.Delivery time means time until shipping of goods.
Test data Page 41 or www.igus.eu/en/test7
125
CF12TPE
10 x d
CF12TPE
10 x d
... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu
950 types from stock no cutting costs ...(for up to 10 cuts of the same type)
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 124
Conductor Multi-wire; adapted in single-wire diameter and pitch length tosuit the requirements in energy chains®.
Core insulation Special FEP-isolating mixture.
Core stranding Cores stranded in one layer with especially short pitch length.
Identification Coaxial elements Schedule Delivery Program
Element shield Extremely bending-resistant braiding made of tinned copperwires. Coverage approx. 70% linear, approx. 90% optical.
Element jacket TPE mixture adapted to suit the requirements in energy chains®.
Outer jacket Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements inenergy chains®. Colour: Steel blue (similar to RAL 5011)
T/R moved -35 °C to +100 °C, minimum bending radius 10 x d
T/R fixed -40 °C to +100 °C, minimum bending radius 7,5 x d
v max. 10 m/s, 5 m/sunsupported/glidinga max. 100 m/s2
Travel distance Freely suspended and gliding travel distances up to 400 m,Class 4
UV-resistant High
Nominal voltage 300/300 V (following DIN VDE 0245).
Testing voltage 1500 V
Oil Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (fol-lowing VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.
Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).
CE Following 2006/95/EG
TPE Coax cable CFKoax1 Class 6.4.4 (6 maximum load requirements 4 travel distance up to 400 m 4 oil-resistant)
50/75 Ω coax cable for maximum load requirements TPE outer jacket oil-resistant biooil-resistant UV-resistant hydrolysis-resistant and microbe-resistant
Imag
e ex
emp
lary
. eplan download, configurator www.igus.eu/en/CFKOAX1 Coax cables and other chainflex® cables in platform technology. e-chain®: System E4/4
Lead free Following 2011/55/EU (RoHS-II)
Clean room According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPAaccording to standard 14644-1
Info The coax elements used in cables of the CF Koax1 series are comparable with a HF75-0.3/1.6 according to MIL-C-17/94-RG179 and thus fit in an RG179 plug!
Typical application area
for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,
semiconductor insertion, indoor cranes, low-temperature applications
CFKoax1.01 1 coaxial element 4,5 9 25CFKoax1.05 5 coaxial elements 10,0 47 135CFKoax2.01 1 coaxial element 4,5 7 23
Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. *New in this catalogue.
Delivery programPart No.
Number of cores External diameterapprox. [mm]
Copperindex[kg/km]
Weight[kg/km]
New*
Order example: CFKoax1.01 – in your desired length (0,5 m steps)CF Koax1 chainflex® series .01 Number of coaxial elements
Please use www.chainflex.eu/en/CFKOAX1 for your online order.
Delivery time 24h or today.Delivery time means time until shipping of goods.
CFKoax1.01 75 1 coaxial element red Steel blueCFKoax1.05 75 5 coaxial elements red, green, blue, white, black Steel blueCFKoax2.01 50 1 coaxial element red Jet black
Part No. Number ofcores
Characteris ticwave impedanceapprox. [Ω]
Colour code
127
CFKoax1TPE
10 x d
CFKoax1TPE
10 x d
... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu
950 types from stock no cutting costs ...(for up to 10 cuts of the same type)
Colour Outer Jacket
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 126