cgc ceiling systems - version one · – dxl system features more than 80 ul designs – cross-tee...

2
Profile Edge Detail LEED Credits Recycled Content: 95% Waste Recycled Regional Rapidly Low-Emitting Daylight Acoustical Reduction Content Materials 1 Renewable Materials and Views Performance Materials MR EQ DX ® / DXL 15 / 16 DONN DX/DXL Suspension System/ ECLIPSE Panels with CLIMAPLUS Performance Features and Benefits 15/16 exposed tee system. Components for use in general and fire-rated applications. Maximum economy and design simplicity. DXL system features more than 80 UL designs (up to 3 hours). Cross-tee override ends resist twisting and give a professionally finished look. Meets or exceeds all national code requirements, including seismic. Patented QUICK-RELEASE cross tees. Custom colour available. Applications Fire-rated, interior general use areas Square Edge Shadowline Tapered Shadowline Shadowline Beveled Pedestals Parchment 103 Manila 246 Beige 142 Straw 143 Sandstone 090 Taupe 107 Charcoal 534 Flat Black 205 Standard Colours White Squash 2661 Safari 2662 Redwood 566 Sienna 565 Halo 206 Mist 053 Nectar 546 Quartz 082 Advantage Colours Silvertone 052 Breeze 2659 Blue Grey 564 Azure 2660 Slate 568 Spruce 567 Tuscany 2663 Sorbet 2658 Year Availability 192

Upload: ngoquynh

Post on 22-Jul-2018

221 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CGC Ceiling Systems - Version One · – DXL system features more than 80 UL designs – Cross-tee override ends resist twisting and give a professionally finished look

EclipsE Panels with ClimaPlus Superior Performance/Donn Brand FinElinE Suspension System

Profile

Edge Detail

LEED CreditsRecycled Content: 95%

Waste Recycled Regional Rapidly Low-Emitting Daylight Acoustical Reduction Content Materials1 Renewable Materials and Views Performance Materials

MR EQ

DX® / DXL™

15/1615/16

Donn DX/DXL Suspension System/EclipsE Panels with ClimaPlus Performance

Features and Benefits– 15/16 exposed tee system. Components for

use in general and fire-rated applications.– Maximum economy and design simplicity.– DXL system features more than 80 UL designs

(up to 3 hours).– Cross-tee override ends resist twisting and give

a professionally finished look.– Meets or exceeds all national code requirements,

including seismic.– Patented Quick-RElEasE™ cross tees.– Custom colour available.

Applications– Fire-rated, interior

general use areas

Square Edge Shadowline Tapered

Shadowline Shadowline Beveled

Pedestals

Parchment 103 Manila 246 Beige 142 Straw 143 Sandstone 090 Taupe 107

Charcoal 534 Flat Black 205

Standard Colours

White

Squash 2661 Safari 2662 Redwood 566 Sienna 565 Halo 206 Mist 053 Nectar 546 Quartz 082

Advantage Colours

Silvertone 052 Breeze 2659 Blue Grey 564 Azure 2660 Slate 568 Spruce 567 Tuscany 2663 Sorbet 2658

Year Availability

192

Page 2: CGC Ceiling Systems - Version One · – DXL system features more than 80 UL designs – Cross-tee override ends resist twisting and give a professionally finished look

Customer ServiceOntario/Atlantic Canada 800-387-2690Quebec/Eastern Ontario 800-361-1310Western Canada 800-242-4418

Web Sites: www.cgcinc.comwww.usgdesignstudio.com www.sustainableceilings.com www.seismicceilings.com

CGC Inc.350 Burnhamthorpe Rd. W., 5th FlMississauga, ON L5B 3J1

Safety First! Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read MSDS and literature before specification and installation.

2009, CGC Inc.Printed in Canada

For information on trademarks refer to EAC_A377

EGR-OG58

Seismic Zones2 Seismic Solutions Rated Load 3

ASTM Class Length Height Item No. Class 4 Colour5 UBC IBC Categories 4 Hanger 5 Hanger 6 Hanger D, E, F Alternate Spacing Spacing Spacing6

Method

15/16 Tee System Main Tee Intermediate 12 1-1/2 DX/ Flat White 0-4 A-F 7/8 Moulding 12 lbs./LF 6.1 lbs./LF 3.6 lbs./LF

Duty 3600mm 38mm DXL247/ Standard ACM7 Clip

DX/DXL3600

Advantage

Heavy Duty 12 1-1/2 DX/ Flat White 0-4 A-F 7/8 Moulding 16 lbs./LF 7.3 lbs./LF 4.9 lbs./LF

DXL267

Standard ACM7 Clip

Advantage

Cross Tee 1 2 1 DX/ Flat White 0-4 A-F 7/8 Moulding

600mm 25mm DXL216/ Standard ACM7 Clip

DXL600

Advantage

Cross Tee 1-1/2 4 1-1/2 DX/ Flat White 0-4 A-F 7/8 Moulding

1200mm 38mm DXL424/ Standard ACM7 Clip

DXL1200

Advantage

DX4229 Class A Flat White 0-4 A-F 7/8 Moulding

Standard ACM7 Clip

Advantage

1 DX/ Class A Flat White 0-4 A-F 7/8 Moulding

25mm DX416/ Standard ACM7 Clip

DX1200

Advantage

5 1-1/2 DX/ Flat White 0-4 A-F 7/8 Moulding

1500mm 38mm DXL524/ Standard ACM7 Clip

DXL1500

Advantage

Wall Angle12 Length Item No. Colour Wall Angle 12 Length Item No. Colour

Moulding 10 10 M20SM-2 Flat White 12 or 10 M7 Flat White

Standard Standard

Advantage

Advantage

Shadowline11 10 MS2745 Flat White 10 M205 Flat White

2 shelf for seismic Standard M20HD Standard

Advantage Heavy Duty Advantage

M20SM

Seismic

7/8"

3/4"11/4"

9/32"

2"

2"

System meets or exceeds load compliance specifications per ASTM C635

7/8"

7/8"

Product literatureData sheet# EGR-OG58

MaterialDouble-web hot-dipped galvanized steel body; steel cap finished with four-step protective coating.

Recycled content25%. For details, see the Sustainability selector.

InstallationMust be installed in compliance with ASTM C636, CISCA or standard industry practices, within all applicable code requirements. See UL Fire Resistance Directory for rated assembly details.

LimitationsSevere Environmental Requirements: Panels in exposed grids in non-fire-

L.A. Research Report ComplianceDonn brand suspension systems manufactured by CGC Interiors, Inc., have been reviewed and are approved by listing in one or more of the following L.A. Research Report numbers: 22179, 23451, 24095.

The City of New York BSA and MEA Report ComplianceDonn suspension systems have been approved by listing in one or more of the following City of New York Board of Standards and Appeals, and Department of Building, Material and Equipment Acceptance reports: BSA 618-60-SM, BSA 184-77-SM, BSA 796-81-SM, MEA 366-93-M, MEA 133-95-M, MEA 312-99-M, MEA 123-00-M.

ASTM C635 Standard for Load ComplianceSystem meets or exceeds load compliance specifications per ASTM C635. Main tees will not deflect more than 1/8 over 48 span (or L/360) in Light Duty, Intermediate Duty or Heavy Duty categories.

Footnotes1. Dependent on location; contact your CGC representative.2. All DX/DXL main-tee and cross-tee connections meet IBC requirements for tension and compression strength.3. Load test data shows uniform load in lbs./LF based on simple span tests in accordance with ASTM C635 deflection limit of L/360. For detailing and module

loading, request AC269QRC.4. UL fire-rated listing, labeling and follow-up applies only to fire-rated components.5. Non-fire-rated only.6. Cross-tee hole punch spacings also available for 20 and 30 modules.7. Available in metric; add “ME” to Item No. Consult Customer Service for colours of metric tees.8. For mouldings information, see Perimeter Interface selector.9. Panels must be specified to be field-cut, field-revealed and to provide widest possible lay-on edge.10. For DXL, channel mouldings are also acceptable in some designs. Check UL Fire Resistance Directory for moulding options.

rated, high-humidity applications: use all-aluminum AX™ or ZXLA™ painted HDG suspension systems with aluminum cap. Panels in exposed grids in fire-rated, high-humidity applications: use ZXLA suspension systems. For all exterior applications, suspension should be reviewed by a structural engineer.

ICC Evaluation Service, Inc., Report ComplianceSuspension systems manufactured by CGC Interiors, Inc., have been reviewed and are approved by listing in ICC-ES Evaluation Reports. Evaluation Reports are subject to reexamination, revision and possible cancellation. Please refer to usgdesignstudio.com for current reports.

Physical Data/Footnotes

2"

1"

New Donn Seismic Solutions – Meets or exceeds all national code requirements with 7/8 wall moulding. – Fulfills requirements for IBC seismic design categories A-F.

– Certified with maximum sq. ft. weights, representing complete ceiling systems. – Compliance with IBC seismic design categories D, E, and F with CGC

Intermediate Duty system without perimeter wires.

193

Suspension Systems

Exposed 15/16 Face