cg - 4 – 56 brital · plate gasket br-06 section spacer profile br-25014 mullion gasket br-04...

8
CG - 4 – 56 4 Sided Fully Capped Curtain Walling System Typical Elevation & Vertical Section BRITAL ALUMINIUM FACADE DESIGNS Typical Elevation See full size details shown on Assembly drawings of Mullions & Transoms in section 4 of this manual Scale 1:40 Spandrel Panel Top Hung Vent 1 Typical Vertical Section Scale 1:20 Top Hung Vent Top Hung Vent Spandrel Panel Spandrel Panel Spandrel Panel Spandrel Panel Spandrel Panel Spandrel Panel Spandrel Panel Fixed Light Fixed Light 27 4 4 Fixed Light 6 4 26 4 5 4 2 4 3 4 * : For typical Firestop details at floor slab see manual pages 4/20 & 4/21 * * 4 Sided Fully Capped Curtain Walling System Transom centres. Back-up wall Height. Storey height Transom centres. Copyright Brital 2003 R5 4/0

Upload: dangthien

Post on 28-Aug-2018

220 views

Category:

Documents


0 download

TRANSCRIPT

CG - 4 – 564 Sided Fully Capped Curtain Walling SystemTypical Elevation & Vertical Section

B R I T A LA L U M I N I U M F A C A D E D E S I G N S

Typical Elevation

See full size details shown on Assembly drawings of Mullions & Transomsin section 4 of this manual

Scale 1:40

Spandrel Panel

Top Hung Vent

1

Typical Vertical SectionScale 1:20

Top Hung VentTop

Hung Vent

Spandrel Panel

Spandrel Panel

Spandrel Panel

Spandrel Panel

Spandrel Panel

Spandrel Panel

Spandrel Panel

FixedLight

FixedLight27

4

4FixedLight

64

264

54

24

34

* : For typical Firestop details at floor slab see manual pages 4/20 & 4/21

*

*

4 Sided Fully Capped Curtain Walling System

Tran

som

cen

tres

.

Back

-up

wal

lH

eigh

t.

Stor

ey h

eigh

t

Tran

som

cen

tres

.

Copyright Brital 2003 R5

4/0

CG - 4 – 564 Sided Fully Capped Curtain Walling SystemMullion, fixed & fixed

B R I T A LA L U M I N I U M F A C A D E D E S I G N S

For mullion and joint sleeve options see sheet 3/1

No 10 x 44mm long Pan head self tapping stainless steel fixing screw. Point type AB

Profile BR-15001

Profile BR-15002A

Thermal break BR-44

Plate Gasket BR-06

Mullion Gasket BR-04

56

12

103

56

24

12

Copyright Brital 2003 R6

4/2

CG - 4 – 564 Sided Fully Capped Curtain Walling SystemMullion, & Spandrel Panels

B R I T A LA L U M I N I U M F A C A D E D E S I G N S

For mullion and joint sleeve options see sheet 3/1

Profile BR-15001

Thermal break BR-44

Plate gasket BR-06

sectionSpacer

Profile BR-25014 Mullion gasket BR-04

Profile BR-15002A

Spacer Section to be bedded on Silicone

Heads of all screws to be sealed

No 8 x 25.4mm long pan head self tapping stainless steel fixing screw. Point type AB

No 10 x 44mm long Pan head self tapping stainless steel fixing screw. Point type AB

56

12

6

56

12

103

Copyright Brital 2003 R6

4/3

CG - 4 – 564 Sided Fully Capped Curtain Walling SystemTypical Mullion Joint Detail

B R I T A LA L U M I N I U M F A C A D E D E S I G N S

For mullion and joint sleeve options see sheet 3/1

Low modulus, neutral cure, Silicone joint sealant between mullions

Mullion joint sleeve( length of sleeve is subject to structural design )

Bond breaker tape to be appliedto joint sleeve at joint position to prevent Silicone bonding to sleeve

Extruded Mullion Bracket BR-MB2

M12

10

10m

m

Mul

lion

Join

t

EQEQ

Mul

lion

Join

t Sl

eeve

26

30

Extruded Mullion Bracket BR-MB2

Copyright Brital 2003 R7

4/11

CG - 4 – 564 Sided Fully Capped Curtain Walling SystemTypical Head, Jamb & Cill Details

B R I T A LA L U M I N I U M F A C A D E D E S I G N S

FFL

Minimum Edge Distance Subject to Anchor Size

Ceiling Board

FloorFinish

Structural fixings to suit site conditions

Plaster Finish

Pressed metal cill 2mm thicK(profile to suit site conditions) screwed to hollow section after sealant is applied.(cill optional)

Pressed angle 32mm x 25mm x 2mm thick screwed to hollow section.

Sealant & backing rod

Dead load of D G Units to be mechanically supported (see details on sheets 6/2, 6/3 & 6/11)

22 x 22 x 1.6 Hollow Section ( profile BR-25024 )

EPDM perimeter membrane bond to structure (minimum 75mm contact)

SlidingHead Fixing

Dead LoadCill Fixing 55

20 ±

10

60

20 ±

10

50

2828

2812 ±6

24

Mullion

Copyright Brital 2003 R7

4/13

CG - 4 – 564 Sided Fully Capped Curtain Walling SystemTypical Transom Details (at ceiling & back-up wall)

B R I T A LA L U M I N I U M F A C A D E D E S I G N S

Cill Board

Ceiling Finish

PlasterFinish

6mm Spandrel panel

Back up wall

For typical details of mullion joint and tie back details see sheet 4/11

Dead load of D G Units to be mechanically supported (see details on sheets 6/2, 6/3 & 6/11)

Mullion

24

2828

5656

Copyright Brital 2003 R6

4/14

CG - 4 – 564 Sided Fully Capped Curtain Walling SystemTypical Transom Details of Cladding Panels

B R I T A LA L U M I N I U M F A C A D E D E S I G N S

Cill Board

Ceiling Finish

PlasterFinish

4mm Cladding panel

Back up wall

For typical details of mullion joint and tie back details see sheet 4/11

20 x 20 x 1.6 Hollow Section

Glazing Support BR-GS2

Dead load of D G Units to be mechanically supported (see details on sheets 6/2, 6/3 & 6/11)

Setting Block BR-S13

Mullion

24

2828

5656

Copyright Brital 2003 R6

4/17

CG - 4 – 564 Sided Fully Capped Curtain Walling SystemTypical Mullion Details of Fixed & Cladding Panels

B R I T A LA L U M I N I U M F A C A D E D E S I G N S

For mullion and joint sleeve options see sheet 3/1

No 10 x 44mm long Pan head self tapping stainless steel fixing screw. Point type AB

Profile BR-15001 Profile BR-15002A

Thermal break BR-44

Plate gasket BR-06

Mullion gasket BR-04

20 x 20 x 1.5 Hollow SectionBR-20046

4mm Cladding panel

56

12

103

56

12

Copyright Brital 2003 R7

4/18