CF2000 INSTALLATION MANUAL Wheatley Hall Road Doncaster South Yorkshire DN2 4NB Tel 01302 321 541 www.cooper-ls.com Assessed to ISO 9001:2000 Certification number 714h/02 Document Drg Ref PR200-50-502-15 QUALITY MANAGEMENT 0832 – CPD – 1089 EN54-2 1997 & A1;2006 EN54-4:1997 & A1;2002 A2:2006 Approved to

Upload: danijel-danicic

Post on 15-Jan-2016

214 views

Category:

Documents


0 download

DESCRIPTION

Cooper uputstvo PP centrala

TRANSCRIPT

Page 1: CF2000 User Manual

CF2000INSTALLATION MANUAL

Wheatley Hall RoadDoncasterSouth Yorkshire DN2 4NB

Tel 01302 321 541wwwcooper-lscom

Assessed to ISO 90012000Certification number 714h02

Document Drg Ref PR200-50-502-15

QUALITYMANAGEMENT

0832 ndash CPD ndash 1089

EN54-2 1997 amp A12006EN54-41997 amp A12002 A22006

Approved to

Introduction to the Manual

CF2000Analogue Addressable Fire Detection System

This manual provides information on the installation operation and maintenance of the Cooper Fire Systems CF2000 System

NOTICE

The operating system of the CF2000 may be revised as a result of enhancements to the system software or hardware Revisions to this manual will be issued and supplied on request and should be logged in the table supplied on the contents page

Intro

ductio

n CAUTION

RISK OF EXPLOSION IF BATTERY IS REPLACEDBY AN INCORRECT TYPE

DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS ( Appendix Page 92 )

Conte

nts

Contents Page

10 System Design amp Installation 5Introduction 6Project Planning 7System Design Guidelines 8

Compatible Equipment 9Detectors 10Call Points 14Sounders 16

Interfaces 173 Channel IO 171 Channel IO 17Zone Monitor Unit 18Shop Unit Interface 18Spur Isolater 194 Way Sounder Circuit 19

Equipment Compatiblity 20System Overview 21Technical Specification 24Optional Functions 26Networking 28External Connections 29Installation 30

Fixing details 31System Wiring 32

20 Commissioning CF2000 34Commissioning Software 35Panel Fault Finding 39Protocol 40

30 Panel Controls and Indicators 41Panel Controls and Indicators 42System Healthly 43View Event 44Fire Event 45View Fires 46View Pre-Alarm 47View Fault 48View Disabled Address 49View Disabled Zone 51View Disabled IO 52View Log 53

Operations Soft Reset 54Evacuate 55Silence Alarms 56Lamp Test 57Weekly Test 58

Conte

nts

Contents Page

Access Level 2Commissioning 60Panel Settings

Erase Log 61Change Password 62Change Lanuage 63Date Time 64System Details 65

NetworkingPanel Address 66Panels in Network 67Network Messaging 68

Testing Testing Device 69Test Zone 70Test Sound Levels 71One Man Walk Test 72Global Flashing LED 73Analogue Levels 74

Device ConfigAdd Device 75Delete Device 76Configure Zones 77

40 Appendix 78Spur Isolator 794 Way Sounder Controller 80Zone Monitor Unit 81Shop Monitor Unit 821 Way Input Output Unit 83Sensor Base Wiring 84System Wiring 85IP66 Wall Sounder 86Internal Wall Sounder 87Base Sounder Wiring 883 Way Input Output Unit 89Loop Powered Beacon 90Call Point 91Battery Disposal Instructions 92

System Installation and Design

Section 1

5

Introduction

CF2000 provides all of the sophisticated features required of a leading edge analogue addressable fire system along with the simple operation and neat installation demanded by installers and building users

The panel can be flush or surface mounted and the generously sized metal back box allows ample facilities for rear or top cable entriesIt is available as a two loop panel with or without an integral printer

A comprehensive range of ancillary devices is available to operate with the CF2000 panel including Optical Ionisation photo-thermal and heat sensors callpoints and a comprehensive range of interfaces

Each of the CF2000 system components has been specifically designed to operate as part of a CF2000 system this provides an assurance that the panel the sensor the interfaces and the ancillaries are all fully compatible with each other and that the full range of system functionality is supported by each device

Each loop of a CF2000 panel can accommodate up to 150 (99 Belgium) addresses Up to 63 panels can be networked together to form a single system capable of operating with over 32000 devices

6

Project Planning

The following is a typical program and timetable for a CF2000 installation project once the initial order has been received

1 Project Meeting

Installer and user to be present system specifications schematic diagram and proposed circuit drawing to be available CF2000 Installation amp Commissioning Guide to be provided

2 Equipment Fix

Typically 2 weeks notice is required for equipment to be delivered Cable to be installed and basesback boxes to be fitted Then fire sensors call points alarm sounders and interface units can installed

3 Address Schedule

Schedule of sensor locations to be completed by installer and returned to enable System programming

4 Auto Learn

Fire panelrepeater panels to be installed and terminated System to be powered up by installer and auto learn mode activated (see Auto Learn section) System to be tested and verified by installer prior to final commissioning

5 Final Commissioning

Minimum 2 weeks notice is required from receipt of Address Schedule and Commission request form for a Cooper Fire Systems Service Engineer to attend site to implementoversee the final commissioning procedures (see Commissioning section) in conjunction with the installer

7

Guidelines Systems should to the relevant local standards and codes of practice for the UK this is BS5839 part 1 CF2000 meets all the relevant requirements of BS5839 part 1 2002 Installation planning is simplified by the fact that every addressable CF2000 device contains an integral short circuit isolator Care must be taken to ensure that local standards requirements regarding aspects such as loop coverage area covered by a single spur and cable specification are observed

There may be certain applications in which deviations from the code may be necessary and these must be listed on the commissioning certificate (See commissioning section)

Loop lengthsThe maximum permitted loop length is 2 km measured from the near to the far terminals on the CF2000 Motherboard PCB There is no minimum limit to loop length Any wiring spurs off the loop must be included within the 2 km limit On long loop runs the lengths of wiring rises and falls (between floors down to manual call points) must be included Remember to include these especially when taking loop lengths from plan drawings

Loop loading - total number of addressesThe total number of addresses per loop is 150 (99 Belgium) this includes detectors call points and all other addressable items and call points When designing systems its recommended that allowances are made for future expansion Short circuit isolators are incorporated into every CF2000 loop device including Smoke detectors heat detectors sounders callpoints and interfaces Therefore no further fault protection is required in the event of a single fault none of the devices connected to the loop will fail to operate as the fault will be isolated by the two adjacent devicesSpur connected devices downstream of a cable fault will cease to function

System Design Guidelines

8

Compatible Equipment

Addressable Call Points

CBG370 Addressable call point - Flush 85(H) x 85(W) x 30(D)

CBG370S Addressable call point - Surface 85(H) x 85(W) x 53(D)

CBG370WP Weatherproof addressable call point 108(H) x 108(W) x 65(D)

Analogue Sensors

CAH330 Analogue heat detector 101 Dia x 43(D)

CAP320 Analogue optical smoke detector 101 Dia x 33(D)

CAI310 Analogue ionization smoke detector 101 Dia x 33(D)

CAPT340 Analogue photothermal dual detector 101 Dia x 43(D)

CAB300 Common mounting base 104 Dia x 22(D)

Addressable Interfaces

CSI350 Spur Isolator 85(H) x 145(W) x 58(D)

CIO351 3 Channel IO Unit 130(H) x 180(W) x 60(D)

CZMU352 Zone Monitor Unit 85(H) x 145(W) x 58(D)

CMIO353 230v Relay IO Unit 130(H) x 180(W) x 60(D)

CSC354 4 Way Sounder Controller 300(H) x 300(W) x 74(D)

CSUM355 Shop Unit Monitor 130(H) x 180(W) x 60(D)

Addressable Sounders and Beacons

CAS380 Loop Mounted Base Sounder 102 Dia x 40(D)

CAS381 Wall Sounder 105(H) x 105(W) x 95(D)

CAS381WP Wall Sounder - weatherproof 110(H) x 110(W) x 105(D)

CAB382 Loop Mounted Beacon 93 Dia x 53(D)

CASBB384 Loop Mounted Base SounderBeacon 115 Dia x 35(D)

CASB383 Wall SounderBeacon 106(H) x 106(W) x 91(D)

CASB383WP Wall SounderBeacon IP66 110(H) x 110(W) x 100(D)

Conventional Call Points

CBG375 Flush mounting call point 87(H) x 87(W) x 20(D)

CBG375S Surface mounting call point 87(H) x 87(W) x 53(D)

CBG376 Weatherproof surface call point 110(H) x 110(W) x 65(D)

Conventional Detectors

CPD320 Photoelectric smoke detector 101 Dia x 33(D)

CID310 Ionization smoke detector 101 Dia x 33(D)

CPT340 Combined photothermal detector 101 Dia x 43(D)

CFR330 Fast response heat detector 101 Dia x 43(D)

CMT360 Medium response heat detector 101 Dia x 43(D)

CHT390 High temperature heat detector 101 Dia x 43(D)

CDBB300 Common mounting base 104 Dia x 22(D)

Conventional Sounders

ACR 24V flush mounting electronic sounder 86(H) x 86(W) x 42(D)

CXBBR Surface mounting back box for ACR

SYR 24V low current sounder 105(H) x 105(W) x 95(D)

SQR Base sounder 112 Dia x 30(D)

ROLPRS Electronic sounder - shallow base for indoor applications 93 Dia x 75(D)

ROLPRD Electronic sounder - deep base (Weatherproof) 93 Dia x 105(D)

Conventional SounderBeacons

FLRLRD Combined sounderbeacon deep base 93 Dia x 92(D)

FLRLRS Combined sounderbeacon Shallow base 93 Dia x 121(D)

9

CPD320 Conventional Photoelectric Detector this is the most commonly used detector and is most suitable for detecting slow burning fires

The range of compatible detectors for the CF2000 system consists of the following

CPT340 Conventional Photothermal Detector this is a new addition to the Cooper Fire Systems range of detectors It is the ideal detector for a multi-use environment as it has an excellent response to smouldering and fast burning fires

CMT360 77degC Fixed Conventional Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

Compatible Equipment Conventional Devices

Model CID310 CPD320 CFR330 CMT360 CHT390 CPT340

Operating voltage

Standby current (max) 70microA

Start-up Current (max 20 seconds) 340microA

Alarm current (max) 20mA

Ambient Temperature (max) 45ordmC 60ordmC 75ordmC 75ordmC

Ambient Temperature (min)

Alarm temperature (static) 60ordmC 77ordmC

Heat detector class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 78g

Material

Colour

76g

15 to 30V dc

25mA

30microA

210microA NA

47mm 56mm

100mm

NA

NA

60ordmC

shy20ordmC

34mm

White

90ordmC

NA

0 to 95

43mm

A2R BS CS A2S

PCABS

10

CHT390 92degC Fixed Conventional Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CFR330 Rate of Rise A2R Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CDBB300 Conventional Detector Base

Compatible Equipment Conventional Devices

11

CAP320 Analogue Photoelectric Sensor this is the most commonly used sensors and is most suitable for detecting slow burning fires

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

The range of compatible sensors for the CF2000 system consists of the following

CAPT340 Analogue Photothermal Sensor this is a new addition to the Cooper Fire Systems range of sensors It is the ideal sensor for a multi-use environment as it has an excellent response to smouldering and fast burning fires Photothermal sensors can be programmed for thermal only operation at certain times of day

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Equipment Analogue Devices

Model CAI310 CAP320 CAH330 CAPT340

Operating voltage

Standby current (max)

Alarm current (max)

A1R 50ordmC

BS 65ordmC

CS 80ordmC

Ambient Temperature (min)

A1R 60ordmC

BS 77ordmC

CS 90ordmC

Heat sensor class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 76g 78g

Material

Colour

18 TO 30V dc

220microA

5mA

shy20ordmC

NAA1R BS CS

control panel

selectable

A2S

PCABS

0 to 95

34mm 43mm

NA

White

50ordmC60ordmCAmbient Temperature (max)

NA 60ordmCAlarm temperature (static)

47mm 56mm

100mm

12

CAH330 Analogue Heat SensorHeat sensors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions The CAH330 can be programmed to operate in A1RBS or CS mode of operation depending on the required application and sensitivity requirements

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

CAB300 Analogue Sensor Base

Compatible Equipment Analogue Devices

Short Circuit Isolators

Each of the sensors in his range contain an integral short circuit isolator which operates between the -VE COM IN terminal and the -VE COM OUT terminal The isolator operates in conjuction with the CF2000 Control Panel when a low parallel resistance fault of typically 200W is presented between the +VE and -VE of the loop wiring

Short Circuit Isolation Data

(Integral with each sensor)

Total Loop Resistance for correct

operation of short circuit isolator50Ugrave (max)

Continuous Current allowable through

isolator700mA (max)

Isolator Resistance in closed state 013Ugrave (max)

Leakage Current into direct short

circuit with isolator open13mA (max)

Parallel Fault Resistance to be seen

at the Control Panel for isolators to

open

200Ugrave (typ)

13

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezel

Compatible Sounders

A wide range of sounders are available to operate with CF2000All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

Conventional

CBG375

CBG375S

CBG376WP

14

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for the CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezelThe status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Sounders and Beacons

A wide range of loop powered sounders and beacons are available to operate with the CF2000 consisting of a combined sounder base with a maximum output of 95 dB(A) a standalone sounder with a maximum output of 100 dB(A) that is available in standard or weatherproof versions and a stand alone loop powered beaconFor applications where a discreet dedicated sounder is required a cover plate is available for the white base mounted sounder enabling it to be used as a stand alone wall or ceiling mounted sounderAll of these devices are fully programmable via the sophisticated CF2000 multi stage cause and effect programming facilities

All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

CBG370

CBG370S

CBG370WP

Analogue

15

Base sounder

The CAS380 has been designed specifically to complement the latest generation of Cooper Fire Systems soft addressed detectorsit consists of a first fix bracket and a main body which clips onto the bracket incorporating the sounder and a detector mounting base in a single composite assembly

After the body has been clicked into place and connected a sensor or front cover is then added to complete a very simple quick and neat installationThe cover enables the CAS380 to be used as a discreet stand alone wall or ceiling mounted deviceThe sounder base design incorporates a mechanism that can be activated if required to lock either the sensor or the cover into place to prevent unauthorised removal

Dedicated Stand alone sounders

Stand alone sounders are ideal for applications where greater sound outputs are required than can be achieved with a base sounder or for applications requiring a higher level of resilience or ingress protectionTwo different versions are available standard version and an IP66 rated version

CAS380

CAS381 CAS381WP

CAS380 with sensor fitted CAS380 with CASC fitted

Compatible Equipment

16

Interfaces

CF2000 has been designed to be suitable for a wide range of applications various interfaces have been developed to enable the simple integration of other fire systems or building control and safety systems The following devices are available

3 Channel IO device (CIO351)

CIO351 has 3 input channels and 3 output channels it is used to monitor up to three separate inputs from equipment such as sprinkler flow switches and also to provide 3 separately controlled volt free output contacts which are intended to be used to control external equipment such as air handling plant or access control systemsAll inputs and outputs operate completely independently of each other and can be programmed using the sophisticated cause and effect capabilities of CF2000 to operate either globally or in response to activation of specific devices or specific inputsInputs are monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalInputs are suitable for use as fire signal inputs such as from a sprinkler flow switch however they can also be used to monitor non fire inputs such as external keyswitchesOutputs are rated to switch a maximum of 1A resistive at 30V DCThe CIO351 is supplied in a surface mounting IP65 box

1 Channel IO device with mains rated switching capability (CMIO353)

CMIO353 is a single channel input output unit the output is capable of switching up to 1A at 230V ACCommonly used for applications such as door release controls and plant shut down signaling

The input is monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalThe input is suitable for use as a fire signal input such as from a sprinkler flow switch however it can also be used to monitor non fire inputs such as an external keyswitchThe CIO353 is supplied in a surface mounting IP65 box

CIO351 CMIO353

17

Zone monitor unit (CZMU352)

CZMU352 is designed to enable a zone of compatible conventional detectors and callpoints to be connected into the CF2000 loop it is compatible with up to 20 Cooper Fire Systems conventional detectors connected via CDBB300 basesPlease refer to local standards egBS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone CZMU352 fixes to a standard deep double gang back box and can be either surface or semi recess mounted When semi recessed only the front section protrudes giving a maximum 29mm depth

Shop unit Interface (CSUM355)

CSUM355 accepts a zone of conventional detectors plus an unlimited number of callpoints which can be connected to the same input as the detectors or a separate callpoint input if requiredIt also has a 24V 1A rated relay output and a facility to connect a power supply which can then be monitored for faultIn addition it has the facility to connect two circuits of conventional polarised sounders which are monitored by means of an end of line resistor and powered in alarm conditions from the external power supplyThe sounder circuits can be programmed to operate in pulsed continuous or time delayed mode

Please refer to local standards eg BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone The CSUM355 is supplied in a surface mounting IP65 box

Interfaces

CSUM355

CZUM352

18

(CZMU352)

Spur Isolator (CSI350)

CSI350 enables soft addressing to work when the loop contains spurs it controls the addressing operation so that when the system reaches a spur all devices on the spur are allocated an address before it continues addressing the loopThe device also incorporates a short circuit isolatorBecause each device contains a short circuit isolator only 1 is required at the start of each spur

CSI350 is mounted on a standard deep double gang back box (supplied)

Please refer to BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone

4 Way sounder circuit controller (CS354)

CSC354 provides power for 4 separately controllable conventional sounder circuits each circuit can be separately programmedCSC354 is designed to greatly simplify installation in applications where specialist sounders or beacons are required since it powers the sounders and allows full control of the sounder operation without having to wire the sounder back to the CF2000 control panel

A 4 way unit takes up a single address but each circuit can be independently controlledAn CSC354 unit requires a local un-switched 230V supply and incorporates a back up battery to 24 hours of standby operation followed by a minimum of 30 minutes of full alarm ringingA standby of 72 hours can be achieved at the expense of reduced load capability

Interfaces

CSI350

CSC354

19

Equipment Compatibility

SensorsLoop wired sensors must be of the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional detectors can be connected via an CZMU352 interface The connection of other detector types via an CZMU352 interface is not recommended

Call pointsLoop wired call points must be the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional callpoints can be connected via an CZMU352 interface The connection of other callpoint types via an CZMU352 interface is not recommended

SoundersLoop powered addressable sounders must be of the Cooper Fire Systems 300 series soft addressed analogue type

Conventional sounders can also be connected either to the conventional sounder circuits at the panel or to the loop via a CSC354 addressable sounder controller interface providing they meet the following1) They are suitable for operation between 18V and 28V2) They are polarised and suppressed3) The total alarm load is less than the rating of the panel Alarm Power Interface

Note It is possible to use devices outside these requirements if they are supplied with power from a separate source and switched via a suitable relay

Relay circuitsAdditional relays can be added to the CF2000 system by using either CMIO353 or CIO351 relay units

Relays Auto-dialers and auxiliary equipmentA wide variety of relays and other equipment can be connected to the CF2000 system but you should note the following constraints

1) CF2000 provides monitored outputs to drive fire and fault relays mounted in external equipment External relays should be suppressed If a non-suppressed relay is used then a diode can be connected to suppress any reverse EMF on the release of the relay which might cause the panel to malfunction

2) A 24V DC output is provided at the panel to make it easy to connect ancillary equipment Although the panel can supply a continuous quiescent load of up to 30mA BS5839 precludes this practice and any ancillary equipment you connect should only consume power in the alarm or fault mode to meet the requirements of BS5839

20

System Overview

Simple user interface

The main element of the user interface with CF2000 is a (60mm x 30mm visible area) display which provides comprehensive user information

As well as an LCD display providing full system status information the panel incorporates 32 traditional zone indication LEDs to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the systemIn addition there are a number of system status LEDs designed to give clear status information to non technical users

User configuration and maintenance facilities

CF2000 has comprehensive facilities for on site system configuration whereby the user can add or remove simple devices without the need for a service engineer to visit site For initial configuration or major system changes special PC configuration software is available enabling Cooper Fire Systems personnel to do this more efficiently than can be achieved using the system screen Exiting configurations can be uploaded to the PC so that changes can be made to the existing system rather than having to revert to initial filesDuring the yearly maintenance all terminal under main supply shall be verified

21

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 2: CF2000 User Manual

Introduction to the Manual

CF2000Analogue Addressable Fire Detection System

This manual provides information on the installation operation and maintenance of the Cooper Fire Systems CF2000 System

NOTICE

The operating system of the CF2000 may be revised as a result of enhancements to the system software or hardware Revisions to this manual will be issued and supplied on request and should be logged in the table supplied on the contents page

Intro

ductio

n CAUTION

RISK OF EXPLOSION IF BATTERY IS REPLACEDBY AN INCORRECT TYPE

DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS ( Appendix Page 92 )

Conte

nts

Contents Page

10 System Design amp Installation 5Introduction 6Project Planning 7System Design Guidelines 8

Compatible Equipment 9Detectors 10Call Points 14Sounders 16

Interfaces 173 Channel IO 171 Channel IO 17Zone Monitor Unit 18Shop Unit Interface 18Spur Isolater 194 Way Sounder Circuit 19

Equipment Compatiblity 20System Overview 21Technical Specification 24Optional Functions 26Networking 28External Connections 29Installation 30

Fixing details 31System Wiring 32

20 Commissioning CF2000 34Commissioning Software 35Panel Fault Finding 39Protocol 40

30 Panel Controls and Indicators 41Panel Controls and Indicators 42System Healthly 43View Event 44Fire Event 45View Fires 46View Pre-Alarm 47View Fault 48View Disabled Address 49View Disabled Zone 51View Disabled IO 52View Log 53

Operations Soft Reset 54Evacuate 55Silence Alarms 56Lamp Test 57Weekly Test 58

Conte

nts

Contents Page

Access Level 2Commissioning 60Panel Settings

Erase Log 61Change Password 62Change Lanuage 63Date Time 64System Details 65

NetworkingPanel Address 66Panels in Network 67Network Messaging 68

Testing Testing Device 69Test Zone 70Test Sound Levels 71One Man Walk Test 72Global Flashing LED 73Analogue Levels 74

Device ConfigAdd Device 75Delete Device 76Configure Zones 77

40 Appendix 78Spur Isolator 794 Way Sounder Controller 80Zone Monitor Unit 81Shop Monitor Unit 821 Way Input Output Unit 83Sensor Base Wiring 84System Wiring 85IP66 Wall Sounder 86Internal Wall Sounder 87Base Sounder Wiring 883 Way Input Output Unit 89Loop Powered Beacon 90Call Point 91Battery Disposal Instructions 92

System Installation and Design

Section 1

5

Introduction

CF2000 provides all of the sophisticated features required of a leading edge analogue addressable fire system along with the simple operation and neat installation demanded by installers and building users

The panel can be flush or surface mounted and the generously sized metal back box allows ample facilities for rear or top cable entriesIt is available as a two loop panel with or without an integral printer

A comprehensive range of ancillary devices is available to operate with the CF2000 panel including Optical Ionisation photo-thermal and heat sensors callpoints and a comprehensive range of interfaces

Each of the CF2000 system components has been specifically designed to operate as part of a CF2000 system this provides an assurance that the panel the sensor the interfaces and the ancillaries are all fully compatible with each other and that the full range of system functionality is supported by each device

Each loop of a CF2000 panel can accommodate up to 150 (99 Belgium) addresses Up to 63 panels can be networked together to form a single system capable of operating with over 32000 devices

6

Project Planning

The following is a typical program and timetable for a CF2000 installation project once the initial order has been received

1 Project Meeting

Installer and user to be present system specifications schematic diagram and proposed circuit drawing to be available CF2000 Installation amp Commissioning Guide to be provided

2 Equipment Fix

Typically 2 weeks notice is required for equipment to be delivered Cable to be installed and basesback boxes to be fitted Then fire sensors call points alarm sounders and interface units can installed

3 Address Schedule

Schedule of sensor locations to be completed by installer and returned to enable System programming

4 Auto Learn

Fire panelrepeater panels to be installed and terminated System to be powered up by installer and auto learn mode activated (see Auto Learn section) System to be tested and verified by installer prior to final commissioning

5 Final Commissioning

Minimum 2 weeks notice is required from receipt of Address Schedule and Commission request form for a Cooper Fire Systems Service Engineer to attend site to implementoversee the final commissioning procedures (see Commissioning section) in conjunction with the installer

7

Guidelines Systems should to the relevant local standards and codes of practice for the UK this is BS5839 part 1 CF2000 meets all the relevant requirements of BS5839 part 1 2002 Installation planning is simplified by the fact that every addressable CF2000 device contains an integral short circuit isolator Care must be taken to ensure that local standards requirements regarding aspects such as loop coverage area covered by a single spur and cable specification are observed

There may be certain applications in which deviations from the code may be necessary and these must be listed on the commissioning certificate (See commissioning section)

Loop lengthsThe maximum permitted loop length is 2 km measured from the near to the far terminals on the CF2000 Motherboard PCB There is no minimum limit to loop length Any wiring spurs off the loop must be included within the 2 km limit On long loop runs the lengths of wiring rises and falls (between floors down to manual call points) must be included Remember to include these especially when taking loop lengths from plan drawings

Loop loading - total number of addressesThe total number of addresses per loop is 150 (99 Belgium) this includes detectors call points and all other addressable items and call points When designing systems its recommended that allowances are made for future expansion Short circuit isolators are incorporated into every CF2000 loop device including Smoke detectors heat detectors sounders callpoints and interfaces Therefore no further fault protection is required in the event of a single fault none of the devices connected to the loop will fail to operate as the fault will be isolated by the two adjacent devicesSpur connected devices downstream of a cable fault will cease to function

System Design Guidelines

8

Compatible Equipment

Addressable Call Points

CBG370 Addressable call point - Flush 85(H) x 85(W) x 30(D)

CBG370S Addressable call point - Surface 85(H) x 85(W) x 53(D)

CBG370WP Weatherproof addressable call point 108(H) x 108(W) x 65(D)

Analogue Sensors

CAH330 Analogue heat detector 101 Dia x 43(D)

CAP320 Analogue optical smoke detector 101 Dia x 33(D)

CAI310 Analogue ionization smoke detector 101 Dia x 33(D)

CAPT340 Analogue photothermal dual detector 101 Dia x 43(D)

CAB300 Common mounting base 104 Dia x 22(D)

Addressable Interfaces

CSI350 Spur Isolator 85(H) x 145(W) x 58(D)

CIO351 3 Channel IO Unit 130(H) x 180(W) x 60(D)

CZMU352 Zone Monitor Unit 85(H) x 145(W) x 58(D)

CMIO353 230v Relay IO Unit 130(H) x 180(W) x 60(D)

CSC354 4 Way Sounder Controller 300(H) x 300(W) x 74(D)

CSUM355 Shop Unit Monitor 130(H) x 180(W) x 60(D)

Addressable Sounders and Beacons

CAS380 Loop Mounted Base Sounder 102 Dia x 40(D)

CAS381 Wall Sounder 105(H) x 105(W) x 95(D)

CAS381WP Wall Sounder - weatherproof 110(H) x 110(W) x 105(D)

CAB382 Loop Mounted Beacon 93 Dia x 53(D)

CASBB384 Loop Mounted Base SounderBeacon 115 Dia x 35(D)

CASB383 Wall SounderBeacon 106(H) x 106(W) x 91(D)

CASB383WP Wall SounderBeacon IP66 110(H) x 110(W) x 100(D)

Conventional Call Points

CBG375 Flush mounting call point 87(H) x 87(W) x 20(D)

CBG375S Surface mounting call point 87(H) x 87(W) x 53(D)

CBG376 Weatherproof surface call point 110(H) x 110(W) x 65(D)

Conventional Detectors

CPD320 Photoelectric smoke detector 101 Dia x 33(D)

CID310 Ionization smoke detector 101 Dia x 33(D)

CPT340 Combined photothermal detector 101 Dia x 43(D)

CFR330 Fast response heat detector 101 Dia x 43(D)

CMT360 Medium response heat detector 101 Dia x 43(D)

CHT390 High temperature heat detector 101 Dia x 43(D)

CDBB300 Common mounting base 104 Dia x 22(D)

Conventional Sounders

ACR 24V flush mounting electronic sounder 86(H) x 86(W) x 42(D)

CXBBR Surface mounting back box for ACR

SYR 24V low current sounder 105(H) x 105(W) x 95(D)

SQR Base sounder 112 Dia x 30(D)

ROLPRS Electronic sounder - shallow base for indoor applications 93 Dia x 75(D)

ROLPRD Electronic sounder - deep base (Weatherproof) 93 Dia x 105(D)

Conventional SounderBeacons

FLRLRD Combined sounderbeacon deep base 93 Dia x 92(D)

FLRLRS Combined sounderbeacon Shallow base 93 Dia x 121(D)

9

CPD320 Conventional Photoelectric Detector this is the most commonly used detector and is most suitable for detecting slow burning fires

The range of compatible detectors for the CF2000 system consists of the following

CPT340 Conventional Photothermal Detector this is a new addition to the Cooper Fire Systems range of detectors It is the ideal detector for a multi-use environment as it has an excellent response to smouldering and fast burning fires

CMT360 77degC Fixed Conventional Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

Compatible Equipment Conventional Devices

Model CID310 CPD320 CFR330 CMT360 CHT390 CPT340

Operating voltage

Standby current (max) 70microA

Start-up Current (max 20 seconds) 340microA

Alarm current (max) 20mA

Ambient Temperature (max) 45ordmC 60ordmC 75ordmC 75ordmC

Ambient Temperature (min)

Alarm temperature (static) 60ordmC 77ordmC

Heat detector class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 78g

Material

Colour

76g

15 to 30V dc

25mA

30microA

210microA NA

47mm 56mm

100mm

NA

NA

60ordmC

shy20ordmC

34mm

White

90ordmC

NA

0 to 95

43mm

A2R BS CS A2S

PCABS

10

CHT390 92degC Fixed Conventional Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CFR330 Rate of Rise A2R Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CDBB300 Conventional Detector Base

Compatible Equipment Conventional Devices

11

CAP320 Analogue Photoelectric Sensor this is the most commonly used sensors and is most suitable for detecting slow burning fires

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

The range of compatible sensors for the CF2000 system consists of the following

CAPT340 Analogue Photothermal Sensor this is a new addition to the Cooper Fire Systems range of sensors It is the ideal sensor for a multi-use environment as it has an excellent response to smouldering and fast burning fires Photothermal sensors can be programmed for thermal only operation at certain times of day

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Equipment Analogue Devices

Model CAI310 CAP320 CAH330 CAPT340

Operating voltage

Standby current (max)

Alarm current (max)

A1R 50ordmC

BS 65ordmC

CS 80ordmC

Ambient Temperature (min)

A1R 60ordmC

BS 77ordmC

CS 90ordmC

Heat sensor class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 76g 78g

Material

Colour

18 TO 30V dc

220microA

5mA

shy20ordmC

NAA1R BS CS

control panel

selectable

A2S

PCABS

0 to 95

34mm 43mm

NA

White

50ordmC60ordmCAmbient Temperature (max)

NA 60ordmCAlarm temperature (static)

47mm 56mm

100mm

12

CAH330 Analogue Heat SensorHeat sensors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions The CAH330 can be programmed to operate in A1RBS or CS mode of operation depending on the required application and sensitivity requirements

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

CAB300 Analogue Sensor Base

Compatible Equipment Analogue Devices

Short Circuit Isolators

Each of the sensors in his range contain an integral short circuit isolator which operates between the -VE COM IN terminal and the -VE COM OUT terminal The isolator operates in conjuction with the CF2000 Control Panel when a low parallel resistance fault of typically 200W is presented between the +VE and -VE of the loop wiring

Short Circuit Isolation Data

(Integral with each sensor)

Total Loop Resistance for correct

operation of short circuit isolator50Ugrave (max)

Continuous Current allowable through

isolator700mA (max)

Isolator Resistance in closed state 013Ugrave (max)

Leakage Current into direct short

circuit with isolator open13mA (max)

Parallel Fault Resistance to be seen

at the Control Panel for isolators to

open

200Ugrave (typ)

13

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezel

Compatible Sounders

A wide range of sounders are available to operate with CF2000All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

Conventional

CBG375

CBG375S

CBG376WP

14

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for the CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezelThe status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Sounders and Beacons

A wide range of loop powered sounders and beacons are available to operate with the CF2000 consisting of a combined sounder base with a maximum output of 95 dB(A) a standalone sounder with a maximum output of 100 dB(A) that is available in standard or weatherproof versions and a stand alone loop powered beaconFor applications where a discreet dedicated sounder is required a cover plate is available for the white base mounted sounder enabling it to be used as a stand alone wall or ceiling mounted sounderAll of these devices are fully programmable via the sophisticated CF2000 multi stage cause and effect programming facilities

All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

CBG370

CBG370S

CBG370WP

Analogue

15

Base sounder

The CAS380 has been designed specifically to complement the latest generation of Cooper Fire Systems soft addressed detectorsit consists of a first fix bracket and a main body which clips onto the bracket incorporating the sounder and a detector mounting base in a single composite assembly

After the body has been clicked into place and connected a sensor or front cover is then added to complete a very simple quick and neat installationThe cover enables the CAS380 to be used as a discreet stand alone wall or ceiling mounted deviceThe sounder base design incorporates a mechanism that can be activated if required to lock either the sensor or the cover into place to prevent unauthorised removal

Dedicated Stand alone sounders

Stand alone sounders are ideal for applications where greater sound outputs are required than can be achieved with a base sounder or for applications requiring a higher level of resilience or ingress protectionTwo different versions are available standard version and an IP66 rated version

CAS380

CAS381 CAS381WP

CAS380 with sensor fitted CAS380 with CASC fitted

Compatible Equipment

16

Interfaces

CF2000 has been designed to be suitable for a wide range of applications various interfaces have been developed to enable the simple integration of other fire systems or building control and safety systems The following devices are available

3 Channel IO device (CIO351)

CIO351 has 3 input channels and 3 output channels it is used to monitor up to three separate inputs from equipment such as sprinkler flow switches and also to provide 3 separately controlled volt free output contacts which are intended to be used to control external equipment such as air handling plant or access control systemsAll inputs and outputs operate completely independently of each other and can be programmed using the sophisticated cause and effect capabilities of CF2000 to operate either globally or in response to activation of specific devices or specific inputsInputs are monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalInputs are suitable for use as fire signal inputs such as from a sprinkler flow switch however they can also be used to monitor non fire inputs such as external keyswitchesOutputs are rated to switch a maximum of 1A resistive at 30V DCThe CIO351 is supplied in a surface mounting IP65 box

1 Channel IO device with mains rated switching capability (CMIO353)

CMIO353 is a single channel input output unit the output is capable of switching up to 1A at 230V ACCommonly used for applications such as door release controls and plant shut down signaling

The input is monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalThe input is suitable for use as a fire signal input such as from a sprinkler flow switch however it can also be used to monitor non fire inputs such as an external keyswitchThe CIO353 is supplied in a surface mounting IP65 box

CIO351 CMIO353

17

Zone monitor unit (CZMU352)

CZMU352 is designed to enable a zone of compatible conventional detectors and callpoints to be connected into the CF2000 loop it is compatible with up to 20 Cooper Fire Systems conventional detectors connected via CDBB300 basesPlease refer to local standards egBS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone CZMU352 fixes to a standard deep double gang back box and can be either surface or semi recess mounted When semi recessed only the front section protrudes giving a maximum 29mm depth

Shop unit Interface (CSUM355)

CSUM355 accepts a zone of conventional detectors plus an unlimited number of callpoints which can be connected to the same input as the detectors or a separate callpoint input if requiredIt also has a 24V 1A rated relay output and a facility to connect a power supply which can then be monitored for faultIn addition it has the facility to connect two circuits of conventional polarised sounders which are monitored by means of an end of line resistor and powered in alarm conditions from the external power supplyThe sounder circuits can be programmed to operate in pulsed continuous or time delayed mode

Please refer to local standards eg BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone The CSUM355 is supplied in a surface mounting IP65 box

Interfaces

CSUM355

CZUM352

18

(CZMU352)

Spur Isolator (CSI350)

CSI350 enables soft addressing to work when the loop contains spurs it controls the addressing operation so that when the system reaches a spur all devices on the spur are allocated an address before it continues addressing the loopThe device also incorporates a short circuit isolatorBecause each device contains a short circuit isolator only 1 is required at the start of each spur

CSI350 is mounted on a standard deep double gang back box (supplied)

Please refer to BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone

4 Way sounder circuit controller (CS354)

CSC354 provides power for 4 separately controllable conventional sounder circuits each circuit can be separately programmedCSC354 is designed to greatly simplify installation in applications where specialist sounders or beacons are required since it powers the sounders and allows full control of the sounder operation without having to wire the sounder back to the CF2000 control panel

A 4 way unit takes up a single address but each circuit can be independently controlledAn CSC354 unit requires a local un-switched 230V supply and incorporates a back up battery to 24 hours of standby operation followed by a minimum of 30 minutes of full alarm ringingA standby of 72 hours can be achieved at the expense of reduced load capability

Interfaces

CSI350

CSC354

19

Equipment Compatibility

SensorsLoop wired sensors must be of the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional detectors can be connected via an CZMU352 interface The connection of other detector types via an CZMU352 interface is not recommended

Call pointsLoop wired call points must be the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional callpoints can be connected via an CZMU352 interface The connection of other callpoint types via an CZMU352 interface is not recommended

SoundersLoop powered addressable sounders must be of the Cooper Fire Systems 300 series soft addressed analogue type

Conventional sounders can also be connected either to the conventional sounder circuits at the panel or to the loop via a CSC354 addressable sounder controller interface providing they meet the following1) They are suitable for operation between 18V and 28V2) They are polarised and suppressed3) The total alarm load is less than the rating of the panel Alarm Power Interface

Note It is possible to use devices outside these requirements if they are supplied with power from a separate source and switched via a suitable relay

Relay circuitsAdditional relays can be added to the CF2000 system by using either CMIO353 or CIO351 relay units

Relays Auto-dialers and auxiliary equipmentA wide variety of relays and other equipment can be connected to the CF2000 system but you should note the following constraints

1) CF2000 provides monitored outputs to drive fire and fault relays mounted in external equipment External relays should be suppressed If a non-suppressed relay is used then a diode can be connected to suppress any reverse EMF on the release of the relay which might cause the panel to malfunction

2) A 24V DC output is provided at the panel to make it easy to connect ancillary equipment Although the panel can supply a continuous quiescent load of up to 30mA BS5839 precludes this practice and any ancillary equipment you connect should only consume power in the alarm or fault mode to meet the requirements of BS5839

20

System Overview

Simple user interface

The main element of the user interface with CF2000 is a (60mm x 30mm visible area) display which provides comprehensive user information

As well as an LCD display providing full system status information the panel incorporates 32 traditional zone indication LEDs to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the systemIn addition there are a number of system status LEDs designed to give clear status information to non technical users

User configuration and maintenance facilities

CF2000 has comprehensive facilities for on site system configuration whereby the user can add or remove simple devices without the need for a service engineer to visit site For initial configuration or major system changes special PC configuration software is available enabling Cooper Fire Systems personnel to do this more efficiently than can be achieved using the system screen Exiting configurations can be uploaded to the PC so that changes can be made to the existing system rather than having to revert to initial filesDuring the yearly maintenance all terminal under main supply shall be verified

21

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 3: CF2000 User Manual

Conte

nts

Contents Page

10 System Design amp Installation 5Introduction 6Project Planning 7System Design Guidelines 8

Compatible Equipment 9Detectors 10Call Points 14Sounders 16

Interfaces 173 Channel IO 171 Channel IO 17Zone Monitor Unit 18Shop Unit Interface 18Spur Isolater 194 Way Sounder Circuit 19

Equipment Compatiblity 20System Overview 21Technical Specification 24Optional Functions 26Networking 28External Connections 29Installation 30

Fixing details 31System Wiring 32

20 Commissioning CF2000 34Commissioning Software 35Panel Fault Finding 39Protocol 40

30 Panel Controls and Indicators 41Panel Controls and Indicators 42System Healthly 43View Event 44Fire Event 45View Fires 46View Pre-Alarm 47View Fault 48View Disabled Address 49View Disabled Zone 51View Disabled IO 52View Log 53

Operations Soft Reset 54Evacuate 55Silence Alarms 56Lamp Test 57Weekly Test 58

Conte

nts

Contents Page

Access Level 2Commissioning 60Panel Settings

Erase Log 61Change Password 62Change Lanuage 63Date Time 64System Details 65

NetworkingPanel Address 66Panels in Network 67Network Messaging 68

Testing Testing Device 69Test Zone 70Test Sound Levels 71One Man Walk Test 72Global Flashing LED 73Analogue Levels 74

Device ConfigAdd Device 75Delete Device 76Configure Zones 77

40 Appendix 78Spur Isolator 794 Way Sounder Controller 80Zone Monitor Unit 81Shop Monitor Unit 821 Way Input Output Unit 83Sensor Base Wiring 84System Wiring 85IP66 Wall Sounder 86Internal Wall Sounder 87Base Sounder Wiring 883 Way Input Output Unit 89Loop Powered Beacon 90Call Point 91Battery Disposal Instructions 92

System Installation and Design

Section 1

5

Introduction

CF2000 provides all of the sophisticated features required of a leading edge analogue addressable fire system along with the simple operation and neat installation demanded by installers and building users

The panel can be flush or surface mounted and the generously sized metal back box allows ample facilities for rear or top cable entriesIt is available as a two loop panel with or without an integral printer

A comprehensive range of ancillary devices is available to operate with the CF2000 panel including Optical Ionisation photo-thermal and heat sensors callpoints and a comprehensive range of interfaces

Each of the CF2000 system components has been specifically designed to operate as part of a CF2000 system this provides an assurance that the panel the sensor the interfaces and the ancillaries are all fully compatible with each other and that the full range of system functionality is supported by each device

Each loop of a CF2000 panel can accommodate up to 150 (99 Belgium) addresses Up to 63 panels can be networked together to form a single system capable of operating with over 32000 devices

6

Project Planning

The following is a typical program and timetable for a CF2000 installation project once the initial order has been received

1 Project Meeting

Installer and user to be present system specifications schematic diagram and proposed circuit drawing to be available CF2000 Installation amp Commissioning Guide to be provided

2 Equipment Fix

Typically 2 weeks notice is required for equipment to be delivered Cable to be installed and basesback boxes to be fitted Then fire sensors call points alarm sounders and interface units can installed

3 Address Schedule

Schedule of sensor locations to be completed by installer and returned to enable System programming

4 Auto Learn

Fire panelrepeater panels to be installed and terminated System to be powered up by installer and auto learn mode activated (see Auto Learn section) System to be tested and verified by installer prior to final commissioning

5 Final Commissioning

Minimum 2 weeks notice is required from receipt of Address Schedule and Commission request form for a Cooper Fire Systems Service Engineer to attend site to implementoversee the final commissioning procedures (see Commissioning section) in conjunction with the installer

7

Guidelines Systems should to the relevant local standards and codes of practice for the UK this is BS5839 part 1 CF2000 meets all the relevant requirements of BS5839 part 1 2002 Installation planning is simplified by the fact that every addressable CF2000 device contains an integral short circuit isolator Care must be taken to ensure that local standards requirements regarding aspects such as loop coverage area covered by a single spur and cable specification are observed

There may be certain applications in which deviations from the code may be necessary and these must be listed on the commissioning certificate (See commissioning section)

Loop lengthsThe maximum permitted loop length is 2 km measured from the near to the far terminals on the CF2000 Motherboard PCB There is no minimum limit to loop length Any wiring spurs off the loop must be included within the 2 km limit On long loop runs the lengths of wiring rises and falls (between floors down to manual call points) must be included Remember to include these especially when taking loop lengths from plan drawings

Loop loading - total number of addressesThe total number of addresses per loop is 150 (99 Belgium) this includes detectors call points and all other addressable items and call points When designing systems its recommended that allowances are made for future expansion Short circuit isolators are incorporated into every CF2000 loop device including Smoke detectors heat detectors sounders callpoints and interfaces Therefore no further fault protection is required in the event of a single fault none of the devices connected to the loop will fail to operate as the fault will be isolated by the two adjacent devicesSpur connected devices downstream of a cable fault will cease to function

System Design Guidelines

8

Compatible Equipment

Addressable Call Points

CBG370 Addressable call point - Flush 85(H) x 85(W) x 30(D)

CBG370S Addressable call point - Surface 85(H) x 85(W) x 53(D)

CBG370WP Weatherproof addressable call point 108(H) x 108(W) x 65(D)

Analogue Sensors

CAH330 Analogue heat detector 101 Dia x 43(D)

CAP320 Analogue optical smoke detector 101 Dia x 33(D)

CAI310 Analogue ionization smoke detector 101 Dia x 33(D)

CAPT340 Analogue photothermal dual detector 101 Dia x 43(D)

CAB300 Common mounting base 104 Dia x 22(D)

Addressable Interfaces

CSI350 Spur Isolator 85(H) x 145(W) x 58(D)

CIO351 3 Channel IO Unit 130(H) x 180(W) x 60(D)

CZMU352 Zone Monitor Unit 85(H) x 145(W) x 58(D)

CMIO353 230v Relay IO Unit 130(H) x 180(W) x 60(D)

CSC354 4 Way Sounder Controller 300(H) x 300(W) x 74(D)

CSUM355 Shop Unit Monitor 130(H) x 180(W) x 60(D)

Addressable Sounders and Beacons

CAS380 Loop Mounted Base Sounder 102 Dia x 40(D)

CAS381 Wall Sounder 105(H) x 105(W) x 95(D)

CAS381WP Wall Sounder - weatherproof 110(H) x 110(W) x 105(D)

CAB382 Loop Mounted Beacon 93 Dia x 53(D)

CASBB384 Loop Mounted Base SounderBeacon 115 Dia x 35(D)

CASB383 Wall SounderBeacon 106(H) x 106(W) x 91(D)

CASB383WP Wall SounderBeacon IP66 110(H) x 110(W) x 100(D)

Conventional Call Points

CBG375 Flush mounting call point 87(H) x 87(W) x 20(D)

CBG375S Surface mounting call point 87(H) x 87(W) x 53(D)

CBG376 Weatherproof surface call point 110(H) x 110(W) x 65(D)

Conventional Detectors

CPD320 Photoelectric smoke detector 101 Dia x 33(D)

CID310 Ionization smoke detector 101 Dia x 33(D)

CPT340 Combined photothermal detector 101 Dia x 43(D)

CFR330 Fast response heat detector 101 Dia x 43(D)

CMT360 Medium response heat detector 101 Dia x 43(D)

CHT390 High temperature heat detector 101 Dia x 43(D)

CDBB300 Common mounting base 104 Dia x 22(D)

Conventional Sounders

ACR 24V flush mounting electronic sounder 86(H) x 86(W) x 42(D)

CXBBR Surface mounting back box for ACR

SYR 24V low current sounder 105(H) x 105(W) x 95(D)

SQR Base sounder 112 Dia x 30(D)

ROLPRS Electronic sounder - shallow base for indoor applications 93 Dia x 75(D)

ROLPRD Electronic sounder - deep base (Weatherproof) 93 Dia x 105(D)

Conventional SounderBeacons

FLRLRD Combined sounderbeacon deep base 93 Dia x 92(D)

FLRLRS Combined sounderbeacon Shallow base 93 Dia x 121(D)

9

CPD320 Conventional Photoelectric Detector this is the most commonly used detector and is most suitable for detecting slow burning fires

The range of compatible detectors for the CF2000 system consists of the following

CPT340 Conventional Photothermal Detector this is a new addition to the Cooper Fire Systems range of detectors It is the ideal detector for a multi-use environment as it has an excellent response to smouldering and fast burning fires

CMT360 77degC Fixed Conventional Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

Compatible Equipment Conventional Devices

Model CID310 CPD320 CFR330 CMT360 CHT390 CPT340

Operating voltage

Standby current (max) 70microA

Start-up Current (max 20 seconds) 340microA

Alarm current (max) 20mA

Ambient Temperature (max) 45ordmC 60ordmC 75ordmC 75ordmC

Ambient Temperature (min)

Alarm temperature (static) 60ordmC 77ordmC

Heat detector class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 78g

Material

Colour

76g

15 to 30V dc

25mA

30microA

210microA NA

47mm 56mm

100mm

NA

NA

60ordmC

shy20ordmC

34mm

White

90ordmC

NA

0 to 95

43mm

A2R BS CS A2S

PCABS

10

CHT390 92degC Fixed Conventional Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CFR330 Rate of Rise A2R Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CDBB300 Conventional Detector Base

Compatible Equipment Conventional Devices

11

CAP320 Analogue Photoelectric Sensor this is the most commonly used sensors and is most suitable for detecting slow burning fires

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

The range of compatible sensors for the CF2000 system consists of the following

CAPT340 Analogue Photothermal Sensor this is a new addition to the Cooper Fire Systems range of sensors It is the ideal sensor for a multi-use environment as it has an excellent response to smouldering and fast burning fires Photothermal sensors can be programmed for thermal only operation at certain times of day

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Equipment Analogue Devices

Model CAI310 CAP320 CAH330 CAPT340

Operating voltage

Standby current (max)

Alarm current (max)

A1R 50ordmC

BS 65ordmC

CS 80ordmC

Ambient Temperature (min)

A1R 60ordmC

BS 77ordmC

CS 90ordmC

Heat sensor class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 76g 78g

Material

Colour

18 TO 30V dc

220microA

5mA

shy20ordmC

NAA1R BS CS

control panel

selectable

A2S

PCABS

0 to 95

34mm 43mm

NA

White

50ordmC60ordmCAmbient Temperature (max)

NA 60ordmCAlarm temperature (static)

47mm 56mm

100mm

12

CAH330 Analogue Heat SensorHeat sensors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions The CAH330 can be programmed to operate in A1RBS or CS mode of operation depending on the required application and sensitivity requirements

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

CAB300 Analogue Sensor Base

Compatible Equipment Analogue Devices

Short Circuit Isolators

Each of the sensors in his range contain an integral short circuit isolator which operates between the -VE COM IN terminal and the -VE COM OUT terminal The isolator operates in conjuction with the CF2000 Control Panel when a low parallel resistance fault of typically 200W is presented between the +VE and -VE of the loop wiring

Short Circuit Isolation Data

(Integral with each sensor)

Total Loop Resistance for correct

operation of short circuit isolator50Ugrave (max)

Continuous Current allowable through

isolator700mA (max)

Isolator Resistance in closed state 013Ugrave (max)

Leakage Current into direct short

circuit with isolator open13mA (max)

Parallel Fault Resistance to be seen

at the Control Panel for isolators to

open

200Ugrave (typ)

13

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezel

Compatible Sounders

A wide range of sounders are available to operate with CF2000All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

Conventional

CBG375

CBG375S

CBG376WP

14

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for the CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezelThe status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Sounders and Beacons

A wide range of loop powered sounders and beacons are available to operate with the CF2000 consisting of a combined sounder base with a maximum output of 95 dB(A) a standalone sounder with a maximum output of 100 dB(A) that is available in standard or weatherproof versions and a stand alone loop powered beaconFor applications where a discreet dedicated sounder is required a cover plate is available for the white base mounted sounder enabling it to be used as a stand alone wall or ceiling mounted sounderAll of these devices are fully programmable via the sophisticated CF2000 multi stage cause and effect programming facilities

All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

CBG370

CBG370S

CBG370WP

Analogue

15

Base sounder

The CAS380 has been designed specifically to complement the latest generation of Cooper Fire Systems soft addressed detectorsit consists of a first fix bracket and a main body which clips onto the bracket incorporating the sounder and a detector mounting base in a single composite assembly

After the body has been clicked into place and connected a sensor or front cover is then added to complete a very simple quick and neat installationThe cover enables the CAS380 to be used as a discreet stand alone wall or ceiling mounted deviceThe sounder base design incorporates a mechanism that can be activated if required to lock either the sensor or the cover into place to prevent unauthorised removal

Dedicated Stand alone sounders

Stand alone sounders are ideal for applications where greater sound outputs are required than can be achieved with a base sounder or for applications requiring a higher level of resilience or ingress protectionTwo different versions are available standard version and an IP66 rated version

CAS380

CAS381 CAS381WP

CAS380 with sensor fitted CAS380 with CASC fitted

Compatible Equipment

16

Interfaces

CF2000 has been designed to be suitable for a wide range of applications various interfaces have been developed to enable the simple integration of other fire systems or building control and safety systems The following devices are available

3 Channel IO device (CIO351)

CIO351 has 3 input channels and 3 output channels it is used to monitor up to three separate inputs from equipment such as sprinkler flow switches and also to provide 3 separately controlled volt free output contacts which are intended to be used to control external equipment such as air handling plant or access control systemsAll inputs and outputs operate completely independently of each other and can be programmed using the sophisticated cause and effect capabilities of CF2000 to operate either globally or in response to activation of specific devices or specific inputsInputs are monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalInputs are suitable for use as fire signal inputs such as from a sprinkler flow switch however they can also be used to monitor non fire inputs such as external keyswitchesOutputs are rated to switch a maximum of 1A resistive at 30V DCThe CIO351 is supplied in a surface mounting IP65 box

1 Channel IO device with mains rated switching capability (CMIO353)

CMIO353 is a single channel input output unit the output is capable of switching up to 1A at 230V ACCommonly used for applications such as door release controls and plant shut down signaling

The input is monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalThe input is suitable for use as a fire signal input such as from a sprinkler flow switch however it can also be used to monitor non fire inputs such as an external keyswitchThe CIO353 is supplied in a surface mounting IP65 box

CIO351 CMIO353

17

Zone monitor unit (CZMU352)

CZMU352 is designed to enable a zone of compatible conventional detectors and callpoints to be connected into the CF2000 loop it is compatible with up to 20 Cooper Fire Systems conventional detectors connected via CDBB300 basesPlease refer to local standards egBS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone CZMU352 fixes to a standard deep double gang back box and can be either surface or semi recess mounted When semi recessed only the front section protrudes giving a maximum 29mm depth

Shop unit Interface (CSUM355)

CSUM355 accepts a zone of conventional detectors plus an unlimited number of callpoints which can be connected to the same input as the detectors or a separate callpoint input if requiredIt also has a 24V 1A rated relay output and a facility to connect a power supply which can then be monitored for faultIn addition it has the facility to connect two circuits of conventional polarised sounders which are monitored by means of an end of line resistor and powered in alarm conditions from the external power supplyThe sounder circuits can be programmed to operate in pulsed continuous or time delayed mode

Please refer to local standards eg BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone The CSUM355 is supplied in a surface mounting IP65 box

Interfaces

CSUM355

CZUM352

18

(CZMU352)

Spur Isolator (CSI350)

CSI350 enables soft addressing to work when the loop contains spurs it controls the addressing operation so that when the system reaches a spur all devices on the spur are allocated an address before it continues addressing the loopThe device also incorporates a short circuit isolatorBecause each device contains a short circuit isolator only 1 is required at the start of each spur

CSI350 is mounted on a standard deep double gang back box (supplied)

Please refer to BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone

4 Way sounder circuit controller (CS354)

CSC354 provides power for 4 separately controllable conventional sounder circuits each circuit can be separately programmedCSC354 is designed to greatly simplify installation in applications where specialist sounders or beacons are required since it powers the sounders and allows full control of the sounder operation without having to wire the sounder back to the CF2000 control panel

A 4 way unit takes up a single address but each circuit can be independently controlledAn CSC354 unit requires a local un-switched 230V supply and incorporates a back up battery to 24 hours of standby operation followed by a minimum of 30 minutes of full alarm ringingA standby of 72 hours can be achieved at the expense of reduced load capability

Interfaces

CSI350

CSC354

19

Equipment Compatibility

SensorsLoop wired sensors must be of the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional detectors can be connected via an CZMU352 interface The connection of other detector types via an CZMU352 interface is not recommended

Call pointsLoop wired call points must be the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional callpoints can be connected via an CZMU352 interface The connection of other callpoint types via an CZMU352 interface is not recommended

SoundersLoop powered addressable sounders must be of the Cooper Fire Systems 300 series soft addressed analogue type

Conventional sounders can also be connected either to the conventional sounder circuits at the panel or to the loop via a CSC354 addressable sounder controller interface providing they meet the following1) They are suitable for operation between 18V and 28V2) They are polarised and suppressed3) The total alarm load is less than the rating of the panel Alarm Power Interface

Note It is possible to use devices outside these requirements if they are supplied with power from a separate source and switched via a suitable relay

Relay circuitsAdditional relays can be added to the CF2000 system by using either CMIO353 or CIO351 relay units

Relays Auto-dialers and auxiliary equipmentA wide variety of relays and other equipment can be connected to the CF2000 system but you should note the following constraints

1) CF2000 provides monitored outputs to drive fire and fault relays mounted in external equipment External relays should be suppressed If a non-suppressed relay is used then a diode can be connected to suppress any reverse EMF on the release of the relay which might cause the panel to malfunction

2) A 24V DC output is provided at the panel to make it easy to connect ancillary equipment Although the panel can supply a continuous quiescent load of up to 30mA BS5839 precludes this practice and any ancillary equipment you connect should only consume power in the alarm or fault mode to meet the requirements of BS5839

20

System Overview

Simple user interface

The main element of the user interface with CF2000 is a (60mm x 30mm visible area) display which provides comprehensive user information

As well as an LCD display providing full system status information the panel incorporates 32 traditional zone indication LEDs to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the systemIn addition there are a number of system status LEDs designed to give clear status information to non technical users

User configuration and maintenance facilities

CF2000 has comprehensive facilities for on site system configuration whereby the user can add or remove simple devices without the need for a service engineer to visit site For initial configuration or major system changes special PC configuration software is available enabling Cooper Fire Systems personnel to do this more efficiently than can be achieved using the system screen Exiting configurations can be uploaded to the PC so that changes can be made to the existing system rather than having to revert to initial filesDuring the yearly maintenance all terminal under main supply shall be verified

21

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 4: CF2000 User Manual

Conte

nts

Contents Page

Access Level 2Commissioning 60Panel Settings

Erase Log 61Change Password 62Change Lanuage 63Date Time 64System Details 65

NetworkingPanel Address 66Panels in Network 67Network Messaging 68

Testing Testing Device 69Test Zone 70Test Sound Levels 71One Man Walk Test 72Global Flashing LED 73Analogue Levels 74

Device ConfigAdd Device 75Delete Device 76Configure Zones 77

40 Appendix 78Spur Isolator 794 Way Sounder Controller 80Zone Monitor Unit 81Shop Monitor Unit 821 Way Input Output Unit 83Sensor Base Wiring 84System Wiring 85IP66 Wall Sounder 86Internal Wall Sounder 87Base Sounder Wiring 883 Way Input Output Unit 89Loop Powered Beacon 90Call Point 91Battery Disposal Instructions 92

System Installation and Design

Section 1

5

Introduction

CF2000 provides all of the sophisticated features required of a leading edge analogue addressable fire system along with the simple operation and neat installation demanded by installers and building users

The panel can be flush or surface mounted and the generously sized metal back box allows ample facilities for rear or top cable entriesIt is available as a two loop panel with or without an integral printer

A comprehensive range of ancillary devices is available to operate with the CF2000 panel including Optical Ionisation photo-thermal and heat sensors callpoints and a comprehensive range of interfaces

Each of the CF2000 system components has been specifically designed to operate as part of a CF2000 system this provides an assurance that the panel the sensor the interfaces and the ancillaries are all fully compatible with each other and that the full range of system functionality is supported by each device

Each loop of a CF2000 panel can accommodate up to 150 (99 Belgium) addresses Up to 63 panels can be networked together to form a single system capable of operating with over 32000 devices

6

Project Planning

The following is a typical program and timetable for a CF2000 installation project once the initial order has been received

1 Project Meeting

Installer and user to be present system specifications schematic diagram and proposed circuit drawing to be available CF2000 Installation amp Commissioning Guide to be provided

2 Equipment Fix

Typically 2 weeks notice is required for equipment to be delivered Cable to be installed and basesback boxes to be fitted Then fire sensors call points alarm sounders and interface units can installed

3 Address Schedule

Schedule of sensor locations to be completed by installer and returned to enable System programming

4 Auto Learn

Fire panelrepeater panels to be installed and terminated System to be powered up by installer and auto learn mode activated (see Auto Learn section) System to be tested and verified by installer prior to final commissioning

5 Final Commissioning

Minimum 2 weeks notice is required from receipt of Address Schedule and Commission request form for a Cooper Fire Systems Service Engineer to attend site to implementoversee the final commissioning procedures (see Commissioning section) in conjunction with the installer

7

Guidelines Systems should to the relevant local standards and codes of practice for the UK this is BS5839 part 1 CF2000 meets all the relevant requirements of BS5839 part 1 2002 Installation planning is simplified by the fact that every addressable CF2000 device contains an integral short circuit isolator Care must be taken to ensure that local standards requirements regarding aspects such as loop coverage area covered by a single spur and cable specification are observed

There may be certain applications in which deviations from the code may be necessary and these must be listed on the commissioning certificate (See commissioning section)

Loop lengthsThe maximum permitted loop length is 2 km measured from the near to the far terminals on the CF2000 Motherboard PCB There is no minimum limit to loop length Any wiring spurs off the loop must be included within the 2 km limit On long loop runs the lengths of wiring rises and falls (between floors down to manual call points) must be included Remember to include these especially when taking loop lengths from plan drawings

Loop loading - total number of addressesThe total number of addresses per loop is 150 (99 Belgium) this includes detectors call points and all other addressable items and call points When designing systems its recommended that allowances are made for future expansion Short circuit isolators are incorporated into every CF2000 loop device including Smoke detectors heat detectors sounders callpoints and interfaces Therefore no further fault protection is required in the event of a single fault none of the devices connected to the loop will fail to operate as the fault will be isolated by the two adjacent devicesSpur connected devices downstream of a cable fault will cease to function

System Design Guidelines

8

Compatible Equipment

Addressable Call Points

CBG370 Addressable call point - Flush 85(H) x 85(W) x 30(D)

CBG370S Addressable call point - Surface 85(H) x 85(W) x 53(D)

CBG370WP Weatherproof addressable call point 108(H) x 108(W) x 65(D)

Analogue Sensors

CAH330 Analogue heat detector 101 Dia x 43(D)

CAP320 Analogue optical smoke detector 101 Dia x 33(D)

CAI310 Analogue ionization smoke detector 101 Dia x 33(D)

CAPT340 Analogue photothermal dual detector 101 Dia x 43(D)

CAB300 Common mounting base 104 Dia x 22(D)

Addressable Interfaces

CSI350 Spur Isolator 85(H) x 145(W) x 58(D)

CIO351 3 Channel IO Unit 130(H) x 180(W) x 60(D)

CZMU352 Zone Monitor Unit 85(H) x 145(W) x 58(D)

CMIO353 230v Relay IO Unit 130(H) x 180(W) x 60(D)

CSC354 4 Way Sounder Controller 300(H) x 300(W) x 74(D)

CSUM355 Shop Unit Monitor 130(H) x 180(W) x 60(D)

Addressable Sounders and Beacons

CAS380 Loop Mounted Base Sounder 102 Dia x 40(D)

CAS381 Wall Sounder 105(H) x 105(W) x 95(D)

CAS381WP Wall Sounder - weatherproof 110(H) x 110(W) x 105(D)

CAB382 Loop Mounted Beacon 93 Dia x 53(D)

CASBB384 Loop Mounted Base SounderBeacon 115 Dia x 35(D)

CASB383 Wall SounderBeacon 106(H) x 106(W) x 91(D)

CASB383WP Wall SounderBeacon IP66 110(H) x 110(W) x 100(D)

Conventional Call Points

CBG375 Flush mounting call point 87(H) x 87(W) x 20(D)

CBG375S Surface mounting call point 87(H) x 87(W) x 53(D)

CBG376 Weatherproof surface call point 110(H) x 110(W) x 65(D)

Conventional Detectors

CPD320 Photoelectric smoke detector 101 Dia x 33(D)

CID310 Ionization smoke detector 101 Dia x 33(D)

CPT340 Combined photothermal detector 101 Dia x 43(D)

CFR330 Fast response heat detector 101 Dia x 43(D)

CMT360 Medium response heat detector 101 Dia x 43(D)

CHT390 High temperature heat detector 101 Dia x 43(D)

CDBB300 Common mounting base 104 Dia x 22(D)

Conventional Sounders

ACR 24V flush mounting electronic sounder 86(H) x 86(W) x 42(D)

CXBBR Surface mounting back box for ACR

SYR 24V low current sounder 105(H) x 105(W) x 95(D)

SQR Base sounder 112 Dia x 30(D)

ROLPRS Electronic sounder - shallow base for indoor applications 93 Dia x 75(D)

ROLPRD Electronic sounder - deep base (Weatherproof) 93 Dia x 105(D)

Conventional SounderBeacons

FLRLRD Combined sounderbeacon deep base 93 Dia x 92(D)

FLRLRS Combined sounderbeacon Shallow base 93 Dia x 121(D)

9

CPD320 Conventional Photoelectric Detector this is the most commonly used detector and is most suitable for detecting slow burning fires

The range of compatible detectors for the CF2000 system consists of the following

CPT340 Conventional Photothermal Detector this is a new addition to the Cooper Fire Systems range of detectors It is the ideal detector for a multi-use environment as it has an excellent response to smouldering and fast burning fires

CMT360 77degC Fixed Conventional Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

Compatible Equipment Conventional Devices

Model CID310 CPD320 CFR330 CMT360 CHT390 CPT340

Operating voltage

Standby current (max) 70microA

Start-up Current (max 20 seconds) 340microA

Alarm current (max) 20mA

Ambient Temperature (max) 45ordmC 60ordmC 75ordmC 75ordmC

Ambient Temperature (min)

Alarm temperature (static) 60ordmC 77ordmC

Heat detector class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 78g

Material

Colour

76g

15 to 30V dc

25mA

30microA

210microA NA

47mm 56mm

100mm

NA

NA

60ordmC

shy20ordmC

34mm

White

90ordmC

NA

0 to 95

43mm

A2R BS CS A2S

PCABS

10

CHT390 92degC Fixed Conventional Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CFR330 Rate of Rise A2R Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CDBB300 Conventional Detector Base

Compatible Equipment Conventional Devices

11

CAP320 Analogue Photoelectric Sensor this is the most commonly used sensors and is most suitable for detecting slow burning fires

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

The range of compatible sensors for the CF2000 system consists of the following

CAPT340 Analogue Photothermal Sensor this is a new addition to the Cooper Fire Systems range of sensors It is the ideal sensor for a multi-use environment as it has an excellent response to smouldering and fast burning fires Photothermal sensors can be programmed for thermal only operation at certain times of day

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Equipment Analogue Devices

Model CAI310 CAP320 CAH330 CAPT340

Operating voltage

Standby current (max)

Alarm current (max)

A1R 50ordmC

BS 65ordmC

CS 80ordmC

Ambient Temperature (min)

A1R 60ordmC

BS 77ordmC

CS 90ordmC

Heat sensor class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 76g 78g

Material

Colour

18 TO 30V dc

220microA

5mA

shy20ordmC

NAA1R BS CS

control panel

selectable

A2S

PCABS

0 to 95

34mm 43mm

NA

White

50ordmC60ordmCAmbient Temperature (max)

NA 60ordmCAlarm temperature (static)

47mm 56mm

100mm

12

CAH330 Analogue Heat SensorHeat sensors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions The CAH330 can be programmed to operate in A1RBS or CS mode of operation depending on the required application and sensitivity requirements

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

CAB300 Analogue Sensor Base

Compatible Equipment Analogue Devices

Short Circuit Isolators

Each of the sensors in his range contain an integral short circuit isolator which operates between the -VE COM IN terminal and the -VE COM OUT terminal The isolator operates in conjuction with the CF2000 Control Panel when a low parallel resistance fault of typically 200W is presented between the +VE and -VE of the loop wiring

Short Circuit Isolation Data

(Integral with each sensor)

Total Loop Resistance for correct

operation of short circuit isolator50Ugrave (max)

Continuous Current allowable through

isolator700mA (max)

Isolator Resistance in closed state 013Ugrave (max)

Leakage Current into direct short

circuit with isolator open13mA (max)

Parallel Fault Resistance to be seen

at the Control Panel for isolators to

open

200Ugrave (typ)

13

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezel

Compatible Sounders

A wide range of sounders are available to operate with CF2000All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

Conventional

CBG375

CBG375S

CBG376WP

14

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for the CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezelThe status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Sounders and Beacons

A wide range of loop powered sounders and beacons are available to operate with the CF2000 consisting of a combined sounder base with a maximum output of 95 dB(A) a standalone sounder with a maximum output of 100 dB(A) that is available in standard or weatherproof versions and a stand alone loop powered beaconFor applications where a discreet dedicated sounder is required a cover plate is available for the white base mounted sounder enabling it to be used as a stand alone wall or ceiling mounted sounderAll of these devices are fully programmable via the sophisticated CF2000 multi stage cause and effect programming facilities

All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

CBG370

CBG370S

CBG370WP

Analogue

15

Base sounder

The CAS380 has been designed specifically to complement the latest generation of Cooper Fire Systems soft addressed detectorsit consists of a first fix bracket and a main body which clips onto the bracket incorporating the sounder and a detector mounting base in a single composite assembly

After the body has been clicked into place and connected a sensor or front cover is then added to complete a very simple quick and neat installationThe cover enables the CAS380 to be used as a discreet stand alone wall or ceiling mounted deviceThe sounder base design incorporates a mechanism that can be activated if required to lock either the sensor or the cover into place to prevent unauthorised removal

Dedicated Stand alone sounders

Stand alone sounders are ideal for applications where greater sound outputs are required than can be achieved with a base sounder or for applications requiring a higher level of resilience or ingress protectionTwo different versions are available standard version and an IP66 rated version

CAS380

CAS381 CAS381WP

CAS380 with sensor fitted CAS380 with CASC fitted

Compatible Equipment

16

Interfaces

CF2000 has been designed to be suitable for a wide range of applications various interfaces have been developed to enable the simple integration of other fire systems or building control and safety systems The following devices are available

3 Channel IO device (CIO351)

CIO351 has 3 input channels and 3 output channels it is used to monitor up to three separate inputs from equipment such as sprinkler flow switches and also to provide 3 separately controlled volt free output contacts which are intended to be used to control external equipment such as air handling plant or access control systemsAll inputs and outputs operate completely independently of each other and can be programmed using the sophisticated cause and effect capabilities of CF2000 to operate either globally or in response to activation of specific devices or specific inputsInputs are monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalInputs are suitable for use as fire signal inputs such as from a sprinkler flow switch however they can also be used to monitor non fire inputs such as external keyswitchesOutputs are rated to switch a maximum of 1A resistive at 30V DCThe CIO351 is supplied in a surface mounting IP65 box

1 Channel IO device with mains rated switching capability (CMIO353)

CMIO353 is a single channel input output unit the output is capable of switching up to 1A at 230V ACCommonly used for applications such as door release controls and plant shut down signaling

The input is monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalThe input is suitable for use as a fire signal input such as from a sprinkler flow switch however it can also be used to monitor non fire inputs such as an external keyswitchThe CIO353 is supplied in a surface mounting IP65 box

CIO351 CMIO353

17

Zone monitor unit (CZMU352)

CZMU352 is designed to enable a zone of compatible conventional detectors and callpoints to be connected into the CF2000 loop it is compatible with up to 20 Cooper Fire Systems conventional detectors connected via CDBB300 basesPlease refer to local standards egBS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone CZMU352 fixes to a standard deep double gang back box and can be either surface or semi recess mounted When semi recessed only the front section protrudes giving a maximum 29mm depth

Shop unit Interface (CSUM355)

CSUM355 accepts a zone of conventional detectors plus an unlimited number of callpoints which can be connected to the same input as the detectors or a separate callpoint input if requiredIt also has a 24V 1A rated relay output and a facility to connect a power supply which can then be monitored for faultIn addition it has the facility to connect two circuits of conventional polarised sounders which are monitored by means of an end of line resistor and powered in alarm conditions from the external power supplyThe sounder circuits can be programmed to operate in pulsed continuous or time delayed mode

Please refer to local standards eg BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone The CSUM355 is supplied in a surface mounting IP65 box

Interfaces

CSUM355

CZUM352

18

(CZMU352)

Spur Isolator (CSI350)

CSI350 enables soft addressing to work when the loop contains spurs it controls the addressing operation so that when the system reaches a spur all devices on the spur are allocated an address before it continues addressing the loopThe device also incorporates a short circuit isolatorBecause each device contains a short circuit isolator only 1 is required at the start of each spur

CSI350 is mounted on a standard deep double gang back box (supplied)

Please refer to BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone

4 Way sounder circuit controller (CS354)

CSC354 provides power for 4 separately controllable conventional sounder circuits each circuit can be separately programmedCSC354 is designed to greatly simplify installation in applications where specialist sounders or beacons are required since it powers the sounders and allows full control of the sounder operation without having to wire the sounder back to the CF2000 control panel

A 4 way unit takes up a single address but each circuit can be independently controlledAn CSC354 unit requires a local un-switched 230V supply and incorporates a back up battery to 24 hours of standby operation followed by a minimum of 30 minutes of full alarm ringingA standby of 72 hours can be achieved at the expense of reduced load capability

Interfaces

CSI350

CSC354

19

Equipment Compatibility

SensorsLoop wired sensors must be of the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional detectors can be connected via an CZMU352 interface The connection of other detector types via an CZMU352 interface is not recommended

Call pointsLoop wired call points must be the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional callpoints can be connected via an CZMU352 interface The connection of other callpoint types via an CZMU352 interface is not recommended

SoundersLoop powered addressable sounders must be of the Cooper Fire Systems 300 series soft addressed analogue type

Conventional sounders can also be connected either to the conventional sounder circuits at the panel or to the loop via a CSC354 addressable sounder controller interface providing they meet the following1) They are suitable for operation between 18V and 28V2) They are polarised and suppressed3) The total alarm load is less than the rating of the panel Alarm Power Interface

Note It is possible to use devices outside these requirements if they are supplied with power from a separate source and switched via a suitable relay

Relay circuitsAdditional relays can be added to the CF2000 system by using either CMIO353 or CIO351 relay units

Relays Auto-dialers and auxiliary equipmentA wide variety of relays and other equipment can be connected to the CF2000 system but you should note the following constraints

1) CF2000 provides monitored outputs to drive fire and fault relays mounted in external equipment External relays should be suppressed If a non-suppressed relay is used then a diode can be connected to suppress any reverse EMF on the release of the relay which might cause the panel to malfunction

2) A 24V DC output is provided at the panel to make it easy to connect ancillary equipment Although the panel can supply a continuous quiescent load of up to 30mA BS5839 precludes this practice and any ancillary equipment you connect should only consume power in the alarm or fault mode to meet the requirements of BS5839

20

System Overview

Simple user interface

The main element of the user interface with CF2000 is a (60mm x 30mm visible area) display which provides comprehensive user information

As well as an LCD display providing full system status information the panel incorporates 32 traditional zone indication LEDs to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the systemIn addition there are a number of system status LEDs designed to give clear status information to non technical users

User configuration and maintenance facilities

CF2000 has comprehensive facilities for on site system configuration whereby the user can add or remove simple devices without the need for a service engineer to visit site For initial configuration or major system changes special PC configuration software is available enabling Cooper Fire Systems personnel to do this more efficiently than can be achieved using the system screen Exiting configurations can be uploaded to the PC so that changes can be made to the existing system rather than having to revert to initial filesDuring the yearly maintenance all terminal under main supply shall be verified

21

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 5: CF2000 User Manual

System Installation and Design

Section 1

5

Introduction

CF2000 provides all of the sophisticated features required of a leading edge analogue addressable fire system along with the simple operation and neat installation demanded by installers and building users

The panel can be flush or surface mounted and the generously sized metal back box allows ample facilities for rear or top cable entriesIt is available as a two loop panel with or without an integral printer

A comprehensive range of ancillary devices is available to operate with the CF2000 panel including Optical Ionisation photo-thermal and heat sensors callpoints and a comprehensive range of interfaces

Each of the CF2000 system components has been specifically designed to operate as part of a CF2000 system this provides an assurance that the panel the sensor the interfaces and the ancillaries are all fully compatible with each other and that the full range of system functionality is supported by each device

Each loop of a CF2000 panel can accommodate up to 150 (99 Belgium) addresses Up to 63 panels can be networked together to form a single system capable of operating with over 32000 devices

6

Project Planning

The following is a typical program and timetable for a CF2000 installation project once the initial order has been received

1 Project Meeting

Installer and user to be present system specifications schematic diagram and proposed circuit drawing to be available CF2000 Installation amp Commissioning Guide to be provided

2 Equipment Fix

Typically 2 weeks notice is required for equipment to be delivered Cable to be installed and basesback boxes to be fitted Then fire sensors call points alarm sounders and interface units can installed

3 Address Schedule

Schedule of sensor locations to be completed by installer and returned to enable System programming

4 Auto Learn

Fire panelrepeater panels to be installed and terminated System to be powered up by installer and auto learn mode activated (see Auto Learn section) System to be tested and verified by installer prior to final commissioning

5 Final Commissioning

Minimum 2 weeks notice is required from receipt of Address Schedule and Commission request form for a Cooper Fire Systems Service Engineer to attend site to implementoversee the final commissioning procedures (see Commissioning section) in conjunction with the installer

7

Guidelines Systems should to the relevant local standards and codes of practice for the UK this is BS5839 part 1 CF2000 meets all the relevant requirements of BS5839 part 1 2002 Installation planning is simplified by the fact that every addressable CF2000 device contains an integral short circuit isolator Care must be taken to ensure that local standards requirements regarding aspects such as loop coverage area covered by a single spur and cable specification are observed

There may be certain applications in which deviations from the code may be necessary and these must be listed on the commissioning certificate (See commissioning section)

Loop lengthsThe maximum permitted loop length is 2 km measured from the near to the far terminals on the CF2000 Motherboard PCB There is no minimum limit to loop length Any wiring spurs off the loop must be included within the 2 km limit On long loop runs the lengths of wiring rises and falls (between floors down to manual call points) must be included Remember to include these especially when taking loop lengths from plan drawings

Loop loading - total number of addressesThe total number of addresses per loop is 150 (99 Belgium) this includes detectors call points and all other addressable items and call points When designing systems its recommended that allowances are made for future expansion Short circuit isolators are incorporated into every CF2000 loop device including Smoke detectors heat detectors sounders callpoints and interfaces Therefore no further fault protection is required in the event of a single fault none of the devices connected to the loop will fail to operate as the fault will be isolated by the two adjacent devicesSpur connected devices downstream of a cable fault will cease to function

System Design Guidelines

8

Compatible Equipment

Addressable Call Points

CBG370 Addressable call point - Flush 85(H) x 85(W) x 30(D)

CBG370S Addressable call point - Surface 85(H) x 85(W) x 53(D)

CBG370WP Weatherproof addressable call point 108(H) x 108(W) x 65(D)

Analogue Sensors

CAH330 Analogue heat detector 101 Dia x 43(D)

CAP320 Analogue optical smoke detector 101 Dia x 33(D)

CAI310 Analogue ionization smoke detector 101 Dia x 33(D)

CAPT340 Analogue photothermal dual detector 101 Dia x 43(D)

CAB300 Common mounting base 104 Dia x 22(D)

Addressable Interfaces

CSI350 Spur Isolator 85(H) x 145(W) x 58(D)

CIO351 3 Channel IO Unit 130(H) x 180(W) x 60(D)

CZMU352 Zone Monitor Unit 85(H) x 145(W) x 58(D)

CMIO353 230v Relay IO Unit 130(H) x 180(W) x 60(D)

CSC354 4 Way Sounder Controller 300(H) x 300(W) x 74(D)

CSUM355 Shop Unit Monitor 130(H) x 180(W) x 60(D)

Addressable Sounders and Beacons

CAS380 Loop Mounted Base Sounder 102 Dia x 40(D)

CAS381 Wall Sounder 105(H) x 105(W) x 95(D)

CAS381WP Wall Sounder - weatherproof 110(H) x 110(W) x 105(D)

CAB382 Loop Mounted Beacon 93 Dia x 53(D)

CASBB384 Loop Mounted Base SounderBeacon 115 Dia x 35(D)

CASB383 Wall SounderBeacon 106(H) x 106(W) x 91(D)

CASB383WP Wall SounderBeacon IP66 110(H) x 110(W) x 100(D)

Conventional Call Points

CBG375 Flush mounting call point 87(H) x 87(W) x 20(D)

CBG375S Surface mounting call point 87(H) x 87(W) x 53(D)

CBG376 Weatherproof surface call point 110(H) x 110(W) x 65(D)

Conventional Detectors

CPD320 Photoelectric smoke detector 101 Dia x 33(D)

CID310 Ionization smoke detector 101 Dia x 33(D)

CPT340 Combined photothermal detector 101 Dia x 43(D)

CFR330 Fast response heat detector 101 Dia x 43(D)

CMT360 Medium response heat detector 101 Dia x 43(D)

CHT390 High temperature heat detector 101 Dia x 43(D)

CDBB300 Common mounting base 104 Dia x 22(D)

Conventional Sounders

ACR 24V flush mounting electronic sounder 86(H) x 86(W) x 42(D)

CXBBR Surface mounting back box for ACR

SYR 24V low current sounder 105(H) x 105(W) x 95(D)

SQR Base sounder 112 Dia x 30(D)

ROLPRS Electronic sounder - shallow base for indoor applications 93 Dia x 75(D)

ROLPRD Electronic sounder - deep base (Weatherproof) 93 Dia x 105(D)

Conventional SounderBeacons

FLRLRD Combined sounderbeacon deep base 93 Dia x 92(D)

FLRLRS Combined sounderbeacon Shallow base 93 Dia x 121(D)

9

CPD320 Conventional Photoelectric Detector this is the most commonly used detector and is most suitable for detecting slow burning fires

The range of compatible detectors for the CF2000 system consists of the following

CPT340 Conventional Photothermal Detector this is a new addition to the Cooper Fire Systems range of detectors It is the ideal detector for a multi-use environment as it has an excellent response to smouldering and fast burning fires

CMT360 77degC Fixed Conventional Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

Compatible Equipment Conventional Devices

Model CID310 CPD320 CFR330 CMT360 CHT390 CPT340

Operating voltage

Standby current (max) 70microA

Start-up Current (max 20 seconds) 340microA

Alarm current (max) 20mA

Ambient Temperature (max) 45ordmC 60ordmC 75ordmC 75ordmC

Ambient Temperature (min)

Alarm temperature (static) 60ordmC 77ordmC

Heat detector class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 78g

Material

Colour

76g

15 to 30V dc

25mA

30microA

210microA NA

47mm 56mm

100mm

NA

NA

60ordmC

shy20ordmC

34mm

White

90ordmC

NA

0 to 95

43mm

A2R BS CS A2S

PCABS

10

CHT390 92degC Fixed Conventional Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CFR330 Rate of Rise A2R Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CDBB300 Conventional Detector Base

Compatible Equipment Conventional Devices

11

CAP320 Analogue Photoelectric Sensor this is the most commonly used sensors and is most suitable for detecting slow burning fires

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

The range of compatible sensors for the CF2000 system consists of the following

CAPT340 Analogue Photothermal Sensor this is a new addition to the Cooper Fire Systems range of sensors It is the ideal sensor for a multi-use environment as it has an excellent response to smouldering and fast burning fires Photothermal sensors can be programmed for thermal only operation at certain times of day

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Equipment Analogue Devices

Model CAI310 CAP320 CAH330 CAPT340

Operating voltage

Standby current (max)

Alarm current (max)

A1R 50ordmC

BS 65ordmC

CS 80ordmC

Ambient Temperature (min)

A1R 60ordmC

BS 77ordmC

CS 90ordmC

Heat sensor class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 76g 78g

Material

Colour

18 TO 30V dc

220microA

5mA

shy20ordmC

NAA1R BS CS

control panel

selectable

A2S

PCABS

0 to 95

34mm 43mm

NA

White

50ordmC60ordmCAmbient Temperature (max)

NA 60ordmCAlarm temperature (static)

47mm 56mm

100mm

12

CAH330 Analogue Heat SensorHeat sensors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions The CAH330 can be programmed to operate in A1RBS or CS mode of operation depending on the required application and sensitivity requirements

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

CAB300 Analogue Sensor Base

Compatible Equipment Analogue Devices

Short Circuit Isolators

Each of the sensors in his range contain an integral short circuit isolator which operates between the -VE COM IN terminal and the -VE COM OUT terminal The isolator operates in conjuction with the CF2000 Control Panel when a low parallel resistance fault of typically 200W is presented between the +VE and -VE of the loop wiring

Short Circuit Isolation Data

(Integral with each sensor)

Total Loop Resistance for correct

operation of short circuit isolator50Ugrave (max)

Continuous Current allowable through

isolator700mA (max)

Isolator Resistance in closed state 013Ugrave (max)

Leakage Current into direct short

circuit with isolator open13mA (max)

Parallel Fault Resistance to be seen

at the Control Panel for isolators to

open

200Ugrave (typ)

13

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezel

Compatible Sounders

A wide range of sounders are available to operate with CF2000All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

Conventional

CBG375

CBG375S

CBG376WP

14

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for the CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezelThe status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Sounders and Beacons

A wide range of loop powered sounders and beacons are available to operate with the CF2000 consisting of a combined sounder base with a maximum output of 95 dB(A) a standalone sounder with a maximum output of 100 dB(A) that is available in standard or weatherproof versions and a stand alone loop powered beaconFor applications where a discreet dedicated sounder is required a cover plate is available for the white base mounted sounder enabling it to be used as a stand alone wall or ceiling mounted sounderAll of these devices are fully programmable via the sophisticated CF2000 multi stage cause and effect programming facilities

All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

CBG370

CBG370S

CBG370WP

Analogue

15

Base sounder

The CAS380 has been designed specifically to complement the latest generation of Cooper Fire Systems soft addressed detectorsit consists of a first fix bracket and a main body which clips onto the bracket incorporating the sounder and a detector mounting base in a single composite assembly

After the body has been clicked into place and connected a sensor or front cover is then added to complete a very simple quick and neat installationThe cover enables the CAS380 to be used as a discreet stand alone wall or ceiling mounted deviceThe sounder base design incorporates a mechanism that can be activated if required to lock either the sensor or the cover into place to prevent unauthorised removal

Dedicated Stand alone sounders

Stand alone sounders are ideal for applications where greater sound outputs are required than can be achieved with a base sounder or for applications requiring a higher level of resilience or ingress protectionTwo different versions are available standard version and an IP66 rated version

CAS380

CAS381 CAS381WP

CAS380 with sensor fitted CAS380 with CASC fitted

Compatible Equipment

16

Interfaces

CF2000 has been designed to be suitable for a wide range of applications various interfaces have been developed to enable the simple integration of other fire systems or building control and safety systems The following devices are available

3 Channel IO device (CIO351)

CIO351 has 3 input channels and 3 output channels it is used to monitor up to three separate inputs from equipment such as sprinkler flow switches and also to provide 3 separately controlled volt free output contacts which are intended to be used to control external equipment such as air handling plant or access control systemsAll inputs and outputs operate completely independently of each other and can be programmed using the sophisticated cause and effect capabilities of CF2000 to operate either globally or in response to activation of specific devices or specific inputsInputs are monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalInputs are suitable for use as fire signal inputs such as from a sprinkler flow switch however they can also be used to monitor non fire inputs such as external keyswitchesOutputs are rated to switch a maximum of 1A resistive at 30V DCThe CIO351 is supplied in a surface mounting IP65 box

1 Channel IO device with mains rated switching capability (CMIO353)

CMIO353 is a single channel input output unit the output is capable of switching up to 1A at 230V ACCommonly used for applications such as door release controls and plant shut down signaling

The input is monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalThe input is suitable for use as a fire signal input such as from a sprinkler flow switch however it can also be used to monitor non fire inputs such as an external keyswitchThe CIO353 is supplied in a surface mounting IP65 box

CIO351 CMIO353

17

Zone monitor unit (CZMU352)

CZMU352 is designed to enable a zone of compatible conventional detectors and callpoints to be connected into the CF2000 loop it is compatible with up to 20 Cooper Fire Systems conventional detectors connected via CDBB300 basesPlease refer to local standards egBS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone CZMU352 fixes to a standard deep double gang back box and can be either surface or semi recess mounted When semi recessed only the front section protrudes giving a maximum 29mm depth

Shop unit Interface (CSUM355)

CSUM355 accepts a zone of conventional detectors plus an unlimited number of callpoints which can be connected to the same input as the detectors or a separate callpoint input if requiredIt also has a 24V 1A rated relay output and a facility to connect a power supply which can then be monitored for faultIn addition it has the facility to connect two circuits of conventional polarised sounders which are monitored by means of an end of line resistor and powered in alarm conditions from the external power supplyThe sounder circuits can be programmed to operate in pulsed continuous or time delayed mode

Please refer to local standards eg BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone The CSUM355 is supplied in a surface mounting IP65 box

Interfaces

CSUM355

CZUM352

18

(CZMU352)

Spur Isolator (CSI350)

CSI350 enables soft addressing to work when the loop contains spurs it controls the addressing operation so that when the system reaches a spur all devices on the spur are allocated an address before it continues addressing the loopThe device also incorporates a short circuit isolatorBecause each device contains a short circuit isolator only 1 is required at the start of each spur

CSI350 is mounted on a standard deep double gang back box (supplied)

Please refer to BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone

4 Way sounder circuit controller (CS354)

CSC354 provides power for 4 separately controllable conventional sounder circuits each circuit can be separately programmedCSC354 is designed to greatly simplify installation in applications where specialist sounders or beacons are required since it powers the sounders and allows full control of the sounder operation without having to wire the sounder back to the CF2000 control panel

A 4 way unit takes up a single address but each circuit can be independently controlledAn CSC354 unit requires a local un-switched 230V supply and incorporates a back up battery to 24 hours of standby operation followed by a minimum of 30 minutes of full alarm ringingA standby of 72 hours can be achieved at the expense of reduced load capability

Interfaces

CSI350

CSC354

19

Equipment Compatibility

SensorsLoop wired sensors must be of the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional detectors can be connected via an CZMU352 interface The connection of other detector types via an CZMU352 interface is not recommended

Call pointsLoop wired call points must be the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional callpoints can be connected via an CZMU352 interface The connection of other callpoint types via an CZMU352 interface is not recommended

SoundersLoop powered addressable sounders must be of the Cooper Fire Systems 300 series soft addressed analogue type

Conventional sounders can also be connected either to the conventional sounder circuits at the panel or to the loop via a CSC354 addressable sounder controller interface providing they meet the following1) They are suitable for operation between 18V and 28V2) They are polarised and suppressed3) The total alarm load is less than the rating of the panel Alarm Power Interface

Note It is possible to use devices outside these requirements if they are supplied with power from a separate source and switched via a suitable relay

Relay circuitsAdditional relays can be added to the CF2000 system by using either CMIO353 or CIO351 relay units

Relays Auto-dialers and auxiliary equipmentA wide variety of relays and other equipment can be connected to the CF2000 system but you should note the following constraints

1) CF2000 provides monitored outputs to drive fire and fault relays mounted in external equipment External relays should be suppressed If a non-suppressed relay is used then a diode can be connected to suppress any reverse EMF on the release of the relay which might cause the panel to malfunction

2) A 24V DC output is provided at the panel to make it easy to connect ancillary equipment Although the panel can supply a continuous quiescent load of up to 30mA BS5839 precludes this practice and any ancillary equipment you connect should only consume power in the alarm or fault mode to meet the requirements of BS5839

20

System Overview

Simple user interface

The main element of the user interface with CF2000 is a (60mm x 30mm visible area) display which provides comprehensive user information

As well as an LCD display providing full system status information the panel incorporates 32 traditional zone indication LEDs to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the systemIn addition there are a number of system status LEDs designed to give clear status information to non technical users

User configuration and maintenance facilities

CF2000 has comprehensive facilities for on site system configuration whereby the user can add or remove simple devices without the need for a service engineer to visit site For initial configuration or major system changes special PC configuration software is available enabling Cooper Fire Systems personnel to do this more efficiently than can be achieved using the system screen Exiting configurations can be uploaded to the PC so that changes can be made to the existing system rather than having to revert to initial filesDuring the yearly maintenance all terminal under main supply shall be verified

21

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 6: CF2000 User Manual

Introduction

CF2000 provides all of the sophisticated features required of a leading edge analogue addressable fire system along with the simple operation and neat installation demanded by installers and building users

The panel can be flush or surface mounted and the generously sized metal back box allows ample facilities for rear or top cable entriesIt is available as a two loop panel with or without an integral printer

A comprehensive range of ancillary devices is available to operate with the CF2000 panel including Optical Ionisation photo-thermal and heat sensors callpoints and a comprehensive range of interfaces

Each of the CF2000 system components has been specifically designed to operate as part of a CF2000 system this provides an assurance that the panel the sensor the interfaces and the ancillaries are all fully compatible with each other and that the full range of system functionality is supported by each device

Each loop of a CF2000 panel can accommodate up to 150 (99 Belgium) addresses Up to 63 panels can be networked together to form a single system capable of operating with over 32000 devices

6

Project Planning

The following is a typical program and timetable for a CF2000 installation project once the initial order has been received

1 Project Meeting

Installer and user to be present system specifications schematic diagram and proposed circuit drawing to be available CF2000 Installation amp Commissioning Guide to be provided

2 Equipment Fix

Typically 2 weeks notice is required for equipment to be delivered Cable to be installed and basesback boxes to be fitted Then fire sensors call points alarm sounders and interface units can installed

3 Address Schedule

Schedule of sensor locations to be completed by installer and returned to enable System programming

4 Auto Learn

Fire panelrepeater panels to be installed and terminated System to be powered up by installer and auto learn mode activated (see Auto Learn section) System to be tested and verified by installer prior to final commissioning

5 Final Commissioning

Minimum 2 weeks notice is required from receipt of Address Schedule and Commission request form for a Cooper Fire Systems Service Engineer to attend site to implementoversee the final commissioning procedures (see Commissioning section) in conjunction with the installer

7

Guidelines Systems should to the relevant local standards and codes of practice for the UK this is BS5839 part 1 CF2000 meets all the relevant requirements of BS5839 part 1 2002 Installation planning is simplified by the fact that every addressable CF2000 device contains an integral short circuit isolator Care must be taken to ensure that local standards requirements regarding aspects such as loop coverage area covered by a single spur and cable specification are observed

There may be certain applications in which deviations from the code may be necessary and these must be listed on the commissioning certificate (See commissioning section)

Loop lengthsThe maximum permitted loop length is 2 km measured from the near to the far terminals on the CF2000 Motherboard PCB There is no minimum limit to loop length Any wiring spurs off the loop must be included within the 2 km limit On long loop runs the lengths of wiring rises and falls (between floors down to manual call points) must be included Remember to include these especially when taking loop lengths from plan drawings

Loop loading - total number of addressesThe total number of addresses per loop is 150 (99 Belgium) this includes detectors call points and all other addressable items and call points When designing systems its recommended that allowances are made for future expansion Short circuit isolators are incorporated into every CF2000 loop device including Smoke detectors heat detectors sounders callpoints and interfaces Therefore no further fault protection is required in the event of a single fault none of the devices connected to the loop will fail to operate as the fault will be isolated by the two adjacent devicesSpur connected devices downstream of a cable fault will cease to function

System Design Guidelines

8

Compatible Equipment

Addressable Call Points

CBG370 Addressable call point - Flush 85(H) x 85(W) x 30(D)

CBG370S Addressable call point - Surface 85(H) x 85(W) x 53(D)

CBG370WP Weatherproof addressable call point 108(H) x 108(W) x 65(D)

Analogue Sensors

CAH330 Analogue heat detector 101 Dia x 43(D)

CAP320 Analogue optical smoke detector 101 Dia x 33(D)

CAI310 Analogue ionization smoke detector 101 Dia x 33(D)

CAPT340 Analogue photothermal dual detector 101 Dia x 43(D)

CAB300 Common mounting base 104 Dia x 22(D)

Addressable Interfaces

CSI350 Spur Isolator 85(H) x 145(W) x 58(D)

CIO351 3 Channel IO Unit 130(H) x 180(W) x 60(D)

CZMU352 Zone Monitor Unit 85(H) x 145(W) x 58(D)

CMIO353 230v Relay IO Unit 130(H) x 180(W) x 60(D)

CSC354 4 Way Sounder Controller 300(H) x 300(W) x 74(D)

CSUM355 Shop Unit Monitor 130(H) x 180(W) x 60(D)

Addressable Sounders and Beacons

CAS380 Loop Mounted Base Sounder 102 Dia x 40(D)

CAS381 Wall Sounder 105(H) x 105(W) x 95(D)

CAS381WP Wall Sounder - weatherproof 110(H) x 110(W) x 105(D)

CAB382 Loop Mounted Beacon 93 Dia x 53(D)

CASBB384 Loop Mounted Base SounderBeacon 115 Dia x 35(D)

CASB383 Wall SounderBeacon 106(H) x 106(W) x 91(D)

CASB383WP Wall SounderBeacon IP66 110(H) x 110(W) x 100(D)

Conventional Call Points

CBG375 Flush mounting call point 87(H) x 87(W) x 20(D)

CBG375S Surface mounting call point 87(H) x 87(W) x 53(D)

CBG376 Weatherproof surface call point 110(H) x 110(W) x 65(D)

Conventional Detectors

CPD320 Photoelectric smoke detector 101 Dia x 33(D)

CID310 Ionization smoke detector 101 Dia x 33(D)

CPT340 Combined photothermal detector 101 Dia x 43(D)

CFR330 Fast response heat detector 101 Dia x 43(D)

CMT360 Medium response heat detector 101 Dia x 43(D)

CHT390 High temperature heat detector 101 Dia x 43(D)

CDBB300 Common mounting base 104 Dia x 22(D)

Conventional Sounders

ACR 24V flush mounting electronic sounder 86(H) x 86(W) x 42(D)

CXBBR Surface mounting back box for ACR

SYR 24V low current sounder 105(H) x 105(W) x 95(D)

SQR Base sounder 112 Dia x 30(D)

ROLPRS Electronic sounder - shallow base for indoor applications 93 Dia x 75(D)

ROLPRD Electronic sounder - deep base (Weatherproof) 93 Dia x 105(D)

Conventional SounderBeacons

FLRLRD Combined sounderbeacon deep base 93 Dia x 92(D)

FLRLRS Combined sounderbeacon Shallow base 93 Dia x 121(D)

9

CPD320 Conventional Photoelectric Detector this is the most commonly used detector and is most suitable for detecting slow burning fires

The range of compatible detectors for the CF2000 system consists of the following

CPT340 Conventional Photothermal Detector this is a new addition to the Cooper Fire Systems range of detectors It is the ideal detector for a multi-use environment as it has an excellent response to smouldering and fast burning fires

CMT360 77degC Fixed Conventional Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

Compatible Equipment Conventional Devices

Model CID310 CPD320 CFR330 CMT360 CHT390 CPT340

Operating voltage

Standby current (max) 70microA

Start-up Current (max 20 seconds) 340microA

Alarm current (max) 20mA

Ambient Temperature (max) 45ordmC 60ordmC 75ordmC 75ordmC

Ambient Temperature (min)

Alarm temperature (static) 60ordmC 77ordmC

Heat detector class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 78g

Material

Colour

76g

15 to 30V dc

25mA

30microA

210microA NA

47mm 56mm

100mm

NA

NA

60ordmC

shy20ordmC

34mm

White

90ordmC

NA

0 to 95

43mm

A2R BS CS A2S

PCABS

10

CHT390 92degC Fixed Conventional Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CFR330 Rate of Rise A2R Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CDBB300 Conventional Detector Base

Compatible Equipment Conventional Devices

11

CAP320 Analogue Photoelectric Sensor this is the most commonly used sensors and is most suitable for detecting slow burning fires

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

The range of compatible sensors for the CF2000 system consists of the following

CAPT340 Analogue Photothermal Sensor this is a new addition to the Cooper Fire Systems range of sensors It is the ideal sensor for a multi-use environment as it has an excellent response to smouldering and fast burning fires Photothermal sensors can be programmed for thermal only operation at certain times of day

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Equipment Analogue Devices

Model CAI310 CAP320 CAH330 CAPT340

Operating voltage

Standby current (max)

Alarm current (max)

A1R 50ordmC

BS 65ordmC

CS 80ordmC

Ambient Temperature (min)

A1R 60ordmC

BS 77ordmC

CS 90ordmC

Heat sensor class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 76g 78g

Material

Colour

18 TO 30V dc

220microA

5mA

shy20ordmC

NAA1R BS CS

control panel

selectable

A2S

PCABS

0 to 95

34mm 43mm

NA

White

50ordmC60ordmCAmbient Temperature (max)

NA 60ordmCAlarm temperature (static)

47mm 56mm

100mm

12

CAH330 Analogue Heat SensorHeat sensors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions The CAH330 can be programmed to operate in A1RBS or CS mode of operation depending on the required application and sensitivity requirements

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

CAB300 Analogue Sensor Base

Compatible Equipment Analogue Devices

Short Circuit Isolators

Each of the sensors in his range contain an integral short circuit isolator which operates between the -VE COM IN terminal and the -VE COM OUT terminal The isolator operates in conjuction with the CF2000 Control Panel when a low parallel resistance fault of typically 200W is presented between the +VE and -VE of the loop wiring

Short Circuit Isolation Data

(Integral with each sensor)

Total Loop Resistance for correct

operation of short circuit isolator50Ugrave (max)

Continuous Current allowable through

isolator700mA (max)

Isolator Resistance in closed state 013Ugrave (max)

Leakage Current into direct short

circuit with isolator open13mA (max)

Parallel Fault Resistance to be seen

at the Control Panel for isolators to

open

200Ugrave (typ)

13

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezel

Compatible Sounders

A wide range of sounders are available to operate with CF2000All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

Conventional

CBG375

CBG375S

CBG376WP

14

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for the CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezelThe status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Sounders and Beacons

A wide range of loop powered sounders and beacons are available to operate with the CF2000 consisting of a combined sounder base with a maximum output of 95 dB(A) a standalone sounder with a maximum output of 100 dB(A) that is available in standard or weatherproof versions and a stand alone loop powered beaconFor applications where a discreet dedicated sounder is required a cover plate is available for the white base mounted sounder enabling it to be used as a stand alone wall or ceiling mounted sounderAll of these devices are fully programmable via the sophisticated CF2000 multi stage cause and effect programming facilities

All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

CBG370

CBG370S

CBG370WP

Analogue

15

Base sounder

The CAS380 has been designed specifically to complement the latest generation of Cooper Fire Systems soft addressed detectorsit consists of a first fix bracket and a main body which clips onto the bracket incorporating the sounder and a detector mounting base in a single composite assembly

After the body has been clicked into place and connected a sensor or front cover is then added to complete a very simple quick and neat installationThe cover enables the CAS380 to be used as a discreet stand alone wall or ceiling mounted deviceThe sounder base design incorporates a mechanism that can be activated if required to lock either the sensor or the cover into place to prevent unauthorised removal

Dedicated Stand alone sounders

Stand alone sounders are ideal for applications where greater sound outputs are required than can be achieved with a base sounder or for applications requiring a higher level of resilience or ingress protectionTwo different versions are available standard version and an IP66 rated version

CAS380

CAS381 CAS381WP

CAS380 with sensor fitted CAS380 with CASC fitted

Compatible Equipment

16

Interfaces

CF2000 has been designed to be suitable for a wide range of applications various interfaces have been developed to enable the simple integration of other fire systems or building control and safety systems The following devices are available

3 Channel IO device (CIO351)

CIO351 has 3 input channels and 3 output channels it is used to monitor up to three separate inputs from equipment such as sprinkler flow switches and also to provide 3 separately controlled volt free output contacts which are intended to be used to control external equipment such as air handling plant or access control systemsAll inputs and outputs operate completely independently of each other and can be programmed using the sophisticated cause and effect capabilities of CF2000 to operate either globally or in response to activation of specific devices or specific inputsInputs are monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalInputs are suitable for use as fire signal inputs such as from a sprinkler flow switch however they can also be used to monitor non fire inputs such as external keyswitchesOutputs are rated to switch a maximum of 1A resistive at 30V DCThe CIO351 is supplied in a surface mounting IP65 box

1 Channel IO device with mains rated switching capability (CMIO353)

CMIO353 is a single channel input output unit the output is capable of switching up to 1A at 230V ACCommonly used for applications such as door release controls and plant shut down signaling

The input is monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalThe input is suitable for use as a fire signal input such as from a sprinkler flow switch however it can also be used to monitor non fire inputs such as an external keyswitchThe CIO353 is supplied in a surface mounting IP65 box

CIO351 CMIO353

17

Zone monitor unit (CZMU352)

CZMU352 is designed to enable a zone of compatible conventional detectors and callpoints to be connected into the CF2000 loop it is compatible with up to 20 Cooper Fire Systems conventional detectors connected via CDBB300 basesPlease refer to local standards egBS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone CZMU352 fixes to a standard deep double gang back box and can be either surface or semi recess mounted When semi recessed only the front section protrudes giving a maximum 29mm depth

Shop unit Interface (CSUM355)

CSUM355 accepts a zone of conventional detectors plus an unlimited number of callpoints which can be connected to the same input as the detectors or a separate callpoint input if requiredIt also has a 24V 1A rated relay output and a facility to connect a power supply which can then be monitored for faultIn addition it has the facility to connect two circuits of conventional polarised sounders which are monitored by means of an end of line resistor and powered in alarm conditions from the external power supplyThe sounder circuits can be programmed to operate in pulsed continuous or time delayed mode

Please refer to local standards eg BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone The CSUM355 is supplied in a surface mounting IP65 box

Interfaces

CSUM355

CZUM352

18

(CZMU352)

Spur Isolator (CSI350)

CSI350 enables soft addressing to work when the loop contains spurs it controls the addressing operation so that when the system reaches a spur all devices on the spur are allocated an address before it continues addressing the loopThe device also incorporates a short circuit isolatorBecause each device contains a short circuit isolator only 1 is required at the start of each spur

CSI350 is mounted on a standard deep double gang back box (supplied)

Please refer to BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone

4 Way sounder circuit controller (CS354)

CSC354 provides power for 4 separately controllable conventional sounder circuits each circuit can be separately programmedCSC354 is designed to greatly simplify installation in applications where specialist sounders or beacons are required since it powers the sounders and allows full control of the sounder operation without having to wire the sounder back to the CF2000 control panel

A 4 way unit takes up a single address but each circuit can be independently controlledAn CSC354 unit requires a local un-switched 230V supply and incorporates a back up battery to 24 hours of standby operation followed by a minimum of 30 minutes of full alarm ringingA standby of 72 hours can be achieved at the expense of reduced load capability

Interfaces

CSI350

CSC354

19

Equipment Compatibility

SensorsLoop wired sensors must be of the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional detectors can be connected via an CZMU352 interface The connection of other detector types via an CZMU352 interface is not recommended

Call pointsLoop wired call points must be the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional callpoints can be connected via an CZMU352 interface The connection of other callpoint types via an CZMU352 interface is not recommended

SoundersLoop powered addressable sounders must be of the Cooper Fire Systems 300 series soft addressed analogue type

Conventional sounders can also be connected either to the conventional sounder circuits at the panel or to the loop via a CSC354 addressable sounder controller interface providing they meet the following1) They are suitable for operation between 18V and 28V2) They are polarised and suppressed3) The total alarm load is less than the rating of the panel Alarm Power Interface

Note It is possible to use devices outside these requirements if they are supplied with power from a separate source and switched via a suitable relay

Relay circuitsAdditional relays can be added to the CF2000 system by using either CMIO353 or CIO351 relay units

Relays Auto-dialers and auxiliary equipmentA wide variety of relays and other equipment can be connected to the CF2000 system but you should note the following constraints

1) CF2000 provides monitored outputs to drive fire and fault relays mounted in external equipment External relays should be suppressed If a non-suppressed relay is used then a diode can be connected to suppress any reverse EMF on the release of the relay which might cause the panel to malfunction

2) A 24V DC output is provided at the panel to make it easy to connect ancillary equipment Although the panel can supply a continuous quiescent load of up to 30mA BS5839 precludes this practice and any ancillary equipment you connect should only consume power in the alarm or fault mode to meet the requirements of BS5839

20

System Overview

Simple user interface

The main element of the user interface with CF2000 is a (60mm x 30mm visible area) display which provides comprehensive user information

As well as an LCD display providing full system status information the panel incorporates 32 traditional zone indication LEDs to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the systemIn addition there are a number of system status LEDs designed to give clear status information to non technical users

User configuration and maintenance facilities

CF2000 has comprehensive facilities for on site system configuration whereby the user can add or remove simple devices without the need for a service engineer to visit site For initial configuration or major system changes special PC configuration software is available enabling Cooper Fire Systems personnel to do this more efficiently than can be achieved using the system screen Exiting configurations can be uploaded to the PC so that changes can be made to the existing system rather than having to revert to initial filesDuring the yearly maintenance all terminal under main supply shall be verified

21

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 7: CF2000 User Manual

Project Planning

The following is a typical program and timetable for a CF2000 installation project once the initial order has been received

1 Project Meeting

Installer and user to be present system specifications schematic diagram and proposed circuit drawing to be available CF2000 Installation amp Commissioning Guide to be provided

2 Equipment Fix

Typically 2 weeks notice is required for equipment to be delivered Cable to be installed and basesback boxes to be fitted Then fire sensors call points alarm sounders and interface units can installed

3 Address Schedule

Schedule of sensor locations to be completed by installer and returned to enable System programming

4 Auto Learn

Fire panelrepeater panels to be installed and terminated System to be powered up by installer and auto learn mode activated (see Auto Learn section) System to be tested and verified by installer prior to final commissioning

5 Final Commissioning

Minimum 2 weeks notice is required from receipt of Address Schedule and Commission request form for a Cooper Fire Systems Service Engineer to attend site to implementoversee the final commissioning procedures (see Commissioning section) in conjunction with the installer

7

Guidelines Systems should to the relevant local standards and codes of practice for the UK this is BS5839 part 1 CF2000 meets all the relevant requirements of BS5839 part 1 2002 Installation planning is simplified by the fact that every addressable CF2000 device contains an integral short circuit isolator Care must be taken to ensure that local standards requirements regarding aspects such as loop coverage area covered by a single spur and cable specification are observed

There may be certain applications in which deviations from the code may be necessary and these must be listed on the commissioning certificate (See commissioning section)

Loop lengthsThe maximum permitted loop length is 2 km measured from the near to the far terminals on the CF2000 Motherboard PCB There is no minimum limit to loop length Any wiring spurs off the loop must be included within the 2 km limit On long loop runs the lengths of wiring rises and falls (between floors down to manual call points) must be included Remember to include these especially when taking loop lengths from plan drawings

Loop loading - total number of addressesThe total number of addresses per loop is 150 (99 Belgium) this includes detectors call points and all other addressable items and call points When designing systems its recommended that allowances are made for future expansion Short circuit isolators are incorporated into every CF2000 loop device including Smoke detectors heat detectors sounders callpoints and interfaces Therefore no further fault protection is required in the event of a single fault none of the devices connected to the loop will fail to operate as the fault will be isolated by the two adjacent devicesSpur connected devices downstream of a cable fault will cease to function

System Design Guidelines

8

Compatible Equipment

Addressable Call Points

CBG370 Addressable call point - Flush 85(H) x 85(W) x 30(D)

CBG370S Addressable call point - Surface 85(H) x 85(W) x 53(D)

CBG370WP Weatherproof addressable call point 108(H) x 108(W) x 65(D)

Analogue Sensors

CAH330 Analogue heat detector 101 Dia x 43(D)

CAP320 Analogue optical smoke detector 101 Dia x 33(D)

CAI310 Analogue ionization smoke detector 101 Dia x 33(D)

CAPT340 Analogue photothermal dual detector 101 Dia x 43(D)

CAB300 Common mounting base 104 Dia x 22(D)

Addressable Interfaces

CSI350 Spur Isolator 85(H) x 145(W) x 58(D)

CIO351 3 Channel IO Unit 130(H) x 180(W) x 60(D)

CZMU352 Zone Monitor Unit 85(H) x 145(W) x 58(D)

CMIO353 230v Relay IO Unit 130(H) x 180(W) x 60(D)

CSC354 4 Way Sounder Controller 300(H) x 300(W) x 74(D)

CSUM355 Shop Unit Monitor 130(H) x 180(W) x 60(D)

Addressable Sounders and Beacons

CAS380 Loop Mounted Base Sounder 102 Dia x 40(D)

CAS381 Wall Sounder 105(H) x 105(W) x 95(D)

CAS381WP Wall Sounder - weatherproof 110(H) x 110(W) x 105(D)

CAB382 Loop Mounted Beacon 93 Dia x 53(D)

CASBB384 Loop Mounted Base SounderBeacon 115 Dia x 35(D)

CASB383 Wall SounderBeacon 106(H) x 106(W) x 91(D)

CASB383WP Wall SounderBeacon IP66 110(H) x 110(W) x 100(D)

Conventional Call Points

CBG375 Flush mounting call point 87(H) x 87(W) x 20(D)

CBG375S Surface mounting call point 87(H) x 87(W) x 53(D)

CBG376 Weatherproof surface call point 110(H) x 110(W) x 65(D)

Conventional Detectors

CPD320 Photoelectric smoke detector 101 Dia x 33(D)

CID310 Ionization smoke detector 101 Dia x 33(D)

CPT340 Combined photothermal detector 101 Dia x 43(D)

CFR330 Fast response heat detector 101 Dia x 43(D)

CMT360 Medium response heat detector 101 Dia x 43(D)

CHT390 High temperature heat detector 101 Dia x 43(D)

CDBB300 Common mounting base 104 Dia x 22(D)

Conventional Sounders

ACR 24V flush mounting electronic sounder 86(H) x 86(W) x 42(D)

CXBBR Surface mounting back box for ACR

SYR 24V low current sounder 105(H) x 105(W) x 95(D)

SQR Base sounder 112 Dia x 30(D)

ROLPRS Electronic sounder - shallow base for indoor applications 93 Dia x 75(D)

ROLPRD Electronic sounder - deep base (Weatherproof) 93 Dia x 105(D)

Conventional SounderBeacons

FLRLRD Combined sounderbeacon deep base 93 Dia x 92(D)

FLRLRS Combined sounderbeacon Shallow base 93 Dia x 121(D)

9

CPD320 Conventional Photoelectric Detector this is the most commonly used detector and is most suitable for detecting slow burning fires

The range of compatible detectors for the CF2000 system consists of the following

CPT340 Conventional Photothermal Detector this is a new addition to the Cooper Fire Systems range of detectors It is the ideal detector for a multi-use environment as it has an excellent response to smouldering and fast burning fires

CMT360 77degC Fixed Conventional Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

Compatible Equipment Conventional Devices

Model CID310 CPD320 CFR330 CMT360 CHT390 CPT340

Operating voltage

Standby current (max) 70microA

Start-up Current (max 20 seconds) 340microA

Alarm current (max) 20mA

Ambient Temperature (max) 45ordmC 60ordmC 75ordmC 75ordmC

Ambient Temperature (min)

Alarm temperature (static) 60ordmC 77ordmC

Heat detector class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 78g

Material

Colour

76g

15 to 30V dc

25mA

30microA

210microA NA

47mm 56mm

100mm

NA

NA

60ordmC

shy20ordmC

34mm

White

90ordmC

NA

0 to 95

43mm

A2R BS CS A2S

PCABS

10

CHT390 92degC Fixed Conventional Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CFR330 Rate of Rise A2R Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CDBB300 Conventional Detector Base

Compatible Equipment Conventional Devices

11

CAP320 Analogue Photoelectric Sensor this is the most commonly used sensors and is most suitable for detecting slow burning fires

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

The range of compatible sensors for the CF2000 system consists of the following

CAPT340 Analogue Photothermal Sensor this is a new addition to the Cooper Fire Systems range of sensors It is the ideal sensor for a multi-use environment as it has an excellent response to smouldering and fast burning fires Photothermal sensors can be programmed for thermal only operation at certain times of day

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Equipment Analogue Devices

Model CAI310 CAP320 CAH330 CAPT340

Operating voltage

Standby current (max)

Alarm current (max)

A1R 50ordmC

BS 65ordmC

CS 80ordmC

Ambient Temperature (min)

A1R 60ordmC

BS 77ordmC

CS 90ordmC

Heat sensor class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 76g 78g

Material

Colour

18 TO 30V dc

220microA

5mA

shy20ordmC

NAA1R BS CS

control panel

selectable

A2S

PCABS

0 to 95

34mm 43mm

NA

White

50ordmC60ordmCAmbient Temperature (max)

NA 60ordmCAlarm temperature (static)

47mm 56mm

100mm

12

CAH330 Analogue Heat SensorHeat sensors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions The CAH330 can be programmed to operate in A1RBS or CS mode of operation depending on the required application and sensitivity requirements

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

CAB300 Analogue Sensor Base

Compatible Equipment Analogue Devices

Short Circuit Isolators

Each of the sensors in his range contain an integral short circuit isolator which operates between the -VE COM IN terminal and the -VE COM OUT terminal The isolator operates in conjuction with the CF2000 Control Panel when a low parallel resistance fault of typically 200W is presented between the +VE and -VE of the loop wiring

Short Circuit Isolation Data

(Integral with each sensor)

Total Loop Resistance for correct

operation of short circuit isolator50Ugrave (max)

Continuous Current allowable through

isolator700mA (max)

Isolator Resistance in closed state 013Ugrave (max)

Leakage Current into direct short

circuit with isolator open13mA (max)

Parallel Fault Resistance to be seen

at the Control Panel for isolators to

open

200Ugrave (typ)

13

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezel

Compatible Sounders

A wide range of sounders are available to operate with CF2000All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

Conventional

CBG375

CBG375S

CBG376WP

14

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for the CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezelThe status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Sounders and Beacons

A wide range of loop powered sounders and beacons are available to operate with the CF2000 consisting of a combined sounder base with a maximum output of 95 dB(A) a standalone sounder with a maximum output of 100 dB(A) that is available in standard or weatherproof versions and a stand alone loop powered beaconFor applications where a discreet dedicated sounder is required a cover plate is available for the white base mounted sounder enabling it to be used as a stand alone wall or ceiling mounted sounderAll of these devices are fully programmable via the sophisticated CF2000 multi stage cause and effect programming facilities

All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

CBG370

CBG370S

CBG370WP

Analogue

15

Base sounder

The CAS380 has been designed specifically to complement the latest generation of Cooper Fire Systems soft addressed detectorsit consists of a first fix bracket and a main body which clips onto the bracket incorporating the sounder and a detector mounting base in a single composite assembly

After the body has been clicked into place and connected a sensor or front cover is then added to complete a very simple quick and neat installationThe cover enables the CAS380 to be used as a discreet stand alone wall or ceiling mounted deviceThe sounder base design incorporates a mechanism that can be activated if required to lock either the sensor or the cover into place to prevent unauthorised removal

Dedicated Stand alone sounders

Stand alone sounders are ideal for applications where greater sound outputs are required than can be achieved with a base sounder or for applications requiring a higher level of resilience or ingress protectionTwo different versions are available standard version and an IP66 rated version

CAS380

CAS381 CAS381WP

CAS380 with sensor fitted CAS380 with CASC fitted

Compatible Equipment

16

Interfaces

CF2000 has been designed to be suitable for a wide range of applications various interfaces have been developed to enable the simple integration of other fire systems or building control and safety systems The following devices are available

3 Channel IO device (CIO351)

CIO351 has 3 input channels and 3 output channels it is used to monitor up to three separate inputs from equipment such as sprinkler flow switches and also to provide 3 separately controlled volt free output contacts which are intended to be used to control external equipment such as air handling plant or access control systemsAll inputs and outputs operate completely independently of each other and can be programmed using the sophisticated cause and effect capabilities of CF2000 to operate either globally or in response to activation of specific devices or specific inputsInputs are monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalInputs are suitable for use as fire signal inputs such as from a sprinkler flow switch however they can also be used to monitor non fire inputs such as external keyswitchesOutputs are rated to switch a maximum of 1A resistive at 30V DCThe CIO351 is supplied in a surface mounting IP65 box

1 Channel IO device with mains rated switching capability (CMIO353)

CMIO353 is a single channel input output unit the output is capable of switching up to 1A at 230V ACCommonly used for applications such as door release controls and plant shut down signaling

The input is monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalThe input is suitable for use as a fire signal input such as from a sprinkler flow switch however it can also be used to monitor non fire inputs such as an external keyswitchThe CIO353 is supplied in a surface mounting IP65 box

CIO351 CMIO353

17

Zone monitor unit (CZMU352)

CZMU352 is designed to enable a zone of compatible conventional detectors and callpoints to be connected into the CF2000 loop it is compatible with up to 20 Cooper Fire Systems conventional detectors connected via CDBB300 basesPlease refer to local standards egBS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone CZMU352 fixes to a standard deep double gang back box and can be either surface or semi recess mounted When semi recessed only the front section protrudes giving a maximum 29mm depth

Shop unit Interface (CSUM355)

CSUM355 accepts a zone of conventional detectors plus an unlimited number of callpoints which can be connected to the same input as the detectors or a separate callpoint input if requiredIt also has a 24V 1A rated relay output and a facility to connect a power supply which can then be monitored for faultIn addition it has the facility to connect two circuits of conventional polarised sounders which are monitored by means of an end of line resistor and powered in alarm conditions from the external power supplyThe sounder circuits can be programmed to operate in pulsed continuous or time delayed mode

Please refer to local standards eg BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone The CSUM355 is supplied in a surface mounting IP65 box

Interfaces

CSUM355

CZUM352

18

(CZMU352)

Spur Isolator (CSI350)

CSI350 enables soft addressing to work when the loop contains spurs it controls the addressing operation so that when the system reaches a spur all devices on the spur are allocated an address before it continues addressing the loopThe device also incorporates a short circuit isolatorBecause each device contains a short circuit isolator only 1 is required at the start of each spur

CSI350 is mounted on a standard deep double gang back box (supplied)

Please refer to BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone

4 Way sounder circuit controller (CS354)

CSC354 provides power for 4 separately controllable conventional sounder circuits each circuit can be separately programmedCSC354 is designed to greatly simplify installation in applications where specialist sounders or beacons are required since it powers the sounders and allows full control of the sounder operation without having to wire the sounder back to the CF2000 control panel

A 4 way unit takes up a single address but each circuit can be independently controlledAn CSC354 unit requires a local un-switched 230V supply and incorporates a back up battery to 24 hours of standby operation followed by a minimum of 30 minutes of full alarm ringingA standby of 72 hours can be achieved at the expense of reduced load capability

Interfaces

CSI350

CSC354

19

Equipment Compatibility

SensorsLoop wired sensors must be of the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional detectors can be connected via an CZMU352 interface The connection of other detector types via an CZMU352 interface is not recommended

Call pointsLoop wired call points must be the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional callpoints can be connected via an CZMU352 interface The connection of other callpoint types via an CZMU352 interface is not recommended

SoundersLoop powered addressable sounders must be of the Cooper Fire Systems 300 series soft addressed analogue type

Conventional sounders can also be connected either to the conventional sounder circuits at the panel or to the loop via a CSC354 addressable sounder controller interface providing they meet the following1) They are suitable for operation between 18V and 28V2) They are polarised and suppressed3) The total alarm load is less than the rating of the panel Alarm Power Interface

Note It is possible to use devices outside these requirements if they are supplied with power from a separate source and switched via a suitable relay

Relay circuitsAdditional relays can be added to the CF2000 system by using either CMIO353 or CIO351 relay units

Relays Auto-dialers and auxiliary equipmentA wide variety of relays and other equipment can be connected to the CF2000 system but you should note the following constraints

1) CF2000 provides monitored outputs to drive fire and fault relays mounted in external equipment External relays should be suppressed If a non-suppressed relay is used then a diode can be connected to suppress any reverse EMF on the release of the relay which might cause the panel to malfunction

2) A 24V DC output is provided at the panel to make it easy to connect ancillary equipment Although the panel can supply a continuous quiescent load of up to 30mA BS5839 precludes this practice and any ancillary equipment you connect should only consume power in the alarm or fault mode to meet the requirements of BS5839

20

System Overview

Simple user interface

The main element of the user interface with CF2000 is a (60mm x 30mm visible area) display which provides comprehensive user information

As well as an LCD display providing full system status information the panel incorporates 32 traditional zone indication LEDs to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the systemIn addition there are a number of system status LEDs designed to give clear status information to non technical users

User configuration and maintenance facilities

CF2000 has comprehensive facilities for on site system configuration whereby the user can add or remove simple devices without the need for a service engineer to visit site For initial configuration or major system changes special PC configuration software is available enabling Cooper Fire Systems personnel to do this more efficiently than can be achieved using the system screen Exiting configurations can be uploaded to the PC so that changes can be made to the existing system rather than having to revert to initial filesDuring the yearly maintenance all terminal under main supply shall be verified

21

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 8: CF2000 User Manual

Guidelines Systems should to the relevant local standards and codes of practice for the UK this is BS5839 part 1 CF2000 meets all the relevant requirements of BS5839 part 1 2002 Installation planning is simplified by the fact that every addressable CF2000 device contains an integral short circuit isolator Care must be taken to ensure that local standards requirements regarding aspects such as loop coverage area covered by a single spur and cable specification are observed

There may be certain applications in which deviations from the code may be necessary and these must be listed on the commissioning certificate (See commissioning section)

Loop lengthsThe maximum permitted loop length is 2 km measured from the near to the far terminals on the CF2000 Motherboard PCB There is no minimum limit to loop length Any wiring spurs off the loop must be included within the 2 km limit On long loop runs the lengths of wiring rises and falls (between floors down to manual call points) must be included Remember to include these especially when taking loop lengths from plan drawings

Loop loading - total number of addressesThe total number of addresses per loop is 150 (99 Belgium) this includes detectors call points and all other addressable items and call points When designing systems its recommended that allowances are made for future expansion Short circuit isolators are incorporated into every CF2000 loop device including Smoke detectors heat detectors sounders callpoints and interfaces Therefore no further fault protection is required in the event of a single fault none of the devices connected to the loop will fail to operate as the fault will be isolated by the two adjacent devicesSpur connected devices downstream of a cable fault will cease to function

System Design Guidelines

8

Compatible Equipment

Addressable Call Points

CBG370 Addressable call point - Flush 85(H) x 85(W) x 30(D)

CBG370S Addressable call point - Surface 85(H) x 85(W) x 53(D)

CBG370WP Weatherproof addressable call point 108(H) x 108(W) x 65(D)

Analogue Sensors

CAH330 Analogue heat detector 101 Dia x 43(D)

CAP320 Analogue optical smoke detector 101 Dia x 33(D)

CAI310 Analogue ionization smoke detector 101 Dia x 33(D)

CAPT340 Analogue photothermal dual detector 101 Dia x 43(D)

CAB300 Common mounting base 104 Dia x 22(D)

Addressable Interfaces

CSI350 Spur Isolator 85(H) x 145(W) x 58(D)

CIO351 3 Channel IO Unit 130(H) x 180(W) x 60(D)

CZMU352 Zone Monitor Unit 85(H) x 145(W) x 58(D)

CMIO353 230v Relay IO Unit 130(H) x 180(W) x 60(D)

CSC354 4 Way Sounder Controller 300(H) x 300(W) x 74(D)

CSUM355 Shop Unit Monitor 130(H) x 180(W) x 60(D)

Addressable Sounders and Beacons

CAS380 Loop Mounted Base Sounder 102 Dia x 40(D)

CAS381 Wall Sounder 105(H) x 105(W) x 95(D)

CAS381WP Wall Sounder - weatherproof 110(H) x 110(W) x 105(D)

CAB382 Loop Mounted Beacon 93 Dia x 53(D)

CASBB384 Loop Mounted Base SounderBeacon 115 Dia x 35(D)

CASB383 Wall SounderBeacon 106(H) x 106(W) x 91(D)

CASB383WP Wall SounderBeacon IP66 110(H) x 110(W) x 100(D)

Conventional Call Points

CBG375 Flush mounting call point 87(H) x 87(W) x 20(D)

CBG375S Surface mounting call point 87(H) x 87(W) x 53(D)

CBG376 Weatherproof surface call point 110(H) x 110(W) x 65(D)

Conventional Detectors

CPD320 Photoelectric smoke detector 101 Dia x 33(D)

CID310 Ionization smoke detector 101 Dia x 33(D)

CPT340 Combined photothermal detector 101 Dia x 43(D)

CFR330 Fast response heat detector 101 Dia x 43(D)

CMT360 Medium response heat detector 101 Dia x 43(D)

CHT390 High temperature heat detector 101 Dia x 43(D)

CDBB300 Common mounting base 104 Dia x 22(D)

Conventional Sounders

ACR 24V flush mounting electronic sounder 86(H) x 86(W) x 42(D)

CXBBR Surface mounting back box for ACR

SYR 24V low current sounder 105(H) x 105(W) x 95(D)

SQR Base sounder 112 Dia x 30(D)

ROLPRS Electronic sounder - shallow base for indoor applications 93 Dia x 75(D)

ROLPRD Electronic sounder - deep base (Weatherproof) 93 Dia x 105(D)

Conventional SounderBeacons

FLRLRD Combined sounderbeacon deep base 93 Dia x 92(D)

FLRLRS Combined sounderbeacon Shallow base 93 Dia x 121(D)

9

CPD320 Conventional Photoelectric Detector this is the most commonly used detector and is most suitable for detecting slow burning fires

The range of compatible detectors for the CF2000 system consists of the following

CPT340 Conventional Photothermal Detector this is a new addition to the Cooper Fire Systems range of detectors It is the ideal detector for a multi-use environment as it has an excellent response to smouldering and fast burning fires

CMT360 77degC Fixed Conventional Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

Compatible Equipment Conventional Devices

Model CID310 CPD320 CFR330 CMT360 CHT390 CPT340

Operating voltage

Standby current (max) 70microA

Start-up Current (max 20 seconds) 340microA

Alarm current (max) 20mA

Ambient Temperature (max) 45ordmC 60ordmC 75ordmC 75ordmC

Ambient Temperature (min)

Alarm temperature (static) 60ordmC 77ordmC

Heat detector class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 78g

Material

Colour

76g

15 to 30V dc

25mA

30microA

210microA NA

47mm 56mm

100mm

NA

NA

60ordmC

shy20ordmC

34mm

White

90ordmC

NA

0 to 95

43mm

A2R BS CS A2S

PCABS

10

CHT390 92degC Fixed Conventional Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CFR330 Rate of Rise A2R Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CDBB300 Conventional Detector Base

Compatible Equipment Conventional Devices

11

CAP320 Analogue Photoelectric Sensor this is the most commonly used sensors and is most suitable for detecting slow burning fires

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

The range of compatible sensors for the CF2000 system consists of the following

CAPT340 Analogue Photothermal Sensor this is a new addition to the Cooper Fire Systems range of sensors It is the ideal sensor for a multi-use environment as it has an excellent response to smouldering and fast burning fires Photothermal sensors can be programmed for thermal only operation at certain times of day

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Equipment Analogue Devices

Model CAI310 CAP320 CAH330 CAPT340

Operating voltage

Standby current (max)

Alarm current (max)

A1R 50ordmC

BS 65ordmC

CS 80ordmC

Ambient Temperature (min)

A1R 60ordmC

BS 77ordmC

CS 90ordmC

Heat sensor class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 76g 78g

Material

Colour

18 TO 30V dc

220microA

5mA

shy20ordmC

NAA1R BS CS

control panel

selectable

A2S

PCABS

0 to 95

34mm 43mm

NA

White

50ordmC60ordmCAmbient Temperature (max)

NA 60ordmCAlarm temperature (static)

47mm 56mm

100mm

12

CAH330 Analogue Heat SensorHeat sensors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions The CAH330 can be programmed to operate in A1RBS or CS mode of operation depending on the required application and sensitivity requirements

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

CAB300 Analogue Sensor Base

Compatible Equipment Analogue Devices

Short Circuit Isolators

Each of the sensors in his range contain an integral short circuit isolator which operates between the -VE COM IN terminal and the -VE COM OUT terminal The isolator operates in conjuction with the CF2000 Control Panel when a low parallel resistance fault of typically 200W is presented between the +VE and -VE of the loop wiring

Short Circuit Isolation Data

(Integral with each sensor)

Total Loop Resistance for correct

operation of short circuit isolator50Ugrave (max)

Continuous Current allowable through

isolator700mA (max)

Isolator Resistance in closed state 013Ugrave (max)

Leakage Current into direct short

circuit with isolator open13mA (max)

Parallel Fault Resistance to be seen

at the Control Panel for isolators to

open

200Ugrave (typ)

13

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezel

Compatible Sounders

A wide range of sounders are available to operate with CF2000All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

Conventional

CBG375

CBG375S

CBG376WP

14

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for the CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezelThe status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Sounders and Beacons

A wide range of loop powered sounders and beacons are available to operate with the CF2000 consisting of a combined sounder base with a maximum output of 95 dB(A) a standalone sounder with a maximum output of 100 dB(A) that is available in standard or weatherproof versions and a stand alone loop powered beaconFor applications where a discreet dedicated sounder is required a cover plate is available for the white base mounted sounder enabling it to be used as a stand alone wall or ceiling mounted sounderAll of these devices are fully programmable via the sophisticated CF2000 multi stage cause and effect programming facilities

All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

CBG370

CBG370S

CBG370WP

Analogue

15

Base sounder

The CAS380 has been designed specifically to complement the latest generation of Cooper Fire Systems soft addressed detectorsit consists of a first fix bracket and a main body which clips onto the bracket incorporating the sounder and a detector mounting base in a single composite assembly

After the body has been clicked into place and connected a sensor or front cover is then added to complete a very simple quick and neat installationThe cover enables the CAS380 to be used as a discreet stand alone wall or ceiling mounted deviceThe sounder base design incorporates a mechanism that can be activated if required to lock either the sensor or the cover into place to prevent unauthorised removal

Dedicated Stand alone sounders

Stand alone sounders are ideal for applications where greater sound outputs are required than can be achieved with a base sounder or for applications requiring a higher level of resilience or ingress protectionTwo different versions are available standard version and an IP66 rated version

CAS380

CAS381 CAS381WP

CAS380 with sensor fitted CAS380 with CASC fitted

Compatible Equipment

16

Interfaces

CF2000 has been designed to be suitable for a wide range of applications various interfaces have been developed to enable the simple integration of other fire systems or building control and safety systems The following devices are available

3 Channel IO device (CIO351)

CIO351 has 3 input channels and 3 output channels it is used to monitor up to three separate inputs from equipment such as sprinkler flow switches and also to provide 3 separately controlled volt free output contacts which are intended to be used to control external equipment such as air handling plant or access control systemsAll inputs and outputs operate completely independently of each other and can be programmed using the sophisticated cause and effect capabilities of CF2000 to operate either globally or in response to activation of specific devices or specific inputsInputs are monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalInputs are suitable for use as fire signal inputs such as from a sprinkler flow switch however they can also be used to monitor non fire inputs such as external keyswitchesOutputs are rated to switch a maximum of 1A resistive at 30V DCThe CIO351 is supplied in a surface mounting IP65 box

1 Channel IO device with mains rated switching capability (CMIO353)

CMIO353 is a single channel input output unit the output is capable of switching up to 1A at 230V ACCommonly used for applications such as door release controls and plant shut down signaling

The input is monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalThe input is suitable for use as a fire signal input such as from a sprinkler flow switch however it can also be used to monitor non fire inputs such as an external keyswitchThe CIO353 is supplied in a surface mounting IP65 box

CIO351 CMIO353

17

Zone monitor unit (CZMU352)

CZMU352 is designed to enable a zone of compatible conventional detectors and callpoints to be connected into the CF2000 loop it is compatible with up to 20 Cooper Fire Systems conventional detectors connected via CDBB300 basesPlease refer to local standards egBS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone CZMU352 fixes to a standard deep double gang back box and can be either surface or semi recess mounted When semi recessed only the front section protrudes giving a maximum 29mm depth

Shop unit Interface (CSUM355)

CSUM355 accepts a zone of conventional detectors plus an unlimited number of callpoints which can be connected to the same input as the detectors or a separate callpoint input if requiredIt also has a 24V 1A rated relay output and a facility to connect a power supply which can then be monitored for faultIn addition it has the facility to connect two circuits of conventional polarised sounders which are monitored by means of an end of line resistor and powered in alarm conditions from the external power supplyThe sounder circuits can be programmed to operate in pulsed continuous or time delayed mode

Please refer to local standards eg BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone The CSUM355 is supplied in a surface mounting IP65 box

Interfaces

CSUM355

CZUM352

18

(CZMU352)

Spur Isolator (CSI350)

CSI350 enables soft addressing to work when the loop contains spurs it controls the addressing operation so that when the system reaches a spur all devices on the spur are allocated an address before it continues addressing the loopThe device also incorporates a short circuit isolatorBecause each device contains a short circuit isolator only 1 is required at the start of each spur

CSI350 is mounted on a standard deep double gang back box (supplied)

Please refer to BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone

4 Way sounder circuit controller (CS354)

CSC354 provides power for 4 separately controllable conventional sounder circuits each circuit can be separately programmedCSC354 is designed to greatly simplify installation in applications where specialist sounders or beacons are required since it powers the sounders and allows full control of the sounder operation without having to wire the sounder back to the CF2000 control panel

A 4 way unit takes up a single address but each circuit can be independently controlledAn CSC354 unit requires a local un-switched 230V supply and incorporates a back up battery to 24 hours of standby operation followed by a minimum of 30 minutes of full alarm ringingA standby of 72 hours can be achieved at the expense of reduced load capability

Interfaces

CSI350

CSC354

19

Equipment Compatibility

SensorsLoop wired sensors must be of the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional detectors can be connected via an CZMU352 interface The connection of other detector types via an CZMU352 interface is not recommended

Call pointsLoop wired call points must be the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional callpoints can be connected via an CZMU352 interface The connection of other callpoint types via an CZMU352 interface is not recommended

SoundersLoop powered addressable sounders must be of the Cooper Fire Systems 300 series soft addressed analogue type

Conventional sounders can also be connected either to the conventional sounder circuits at the panel or to the loop via a CSC354 addressable sounder controller interface providing they meet the following1) They are suitable for operation between 18V and 28V2) They are polarised and suppressed3) The total alarm load is less than the rating of the panel Alarm Power Interface

Note It is possible to use devices outside these requirements if they are supplied with power from a separate source and switched via a suitable relay

Relay circuitsAdditional relays can be added to the CF2000 system by using either CMIO353 or CIO351 relay units

Relays Auto-dialers and auxiliary equipmentA wide variety of relays and other equipment can be connected to the CF2000 system but you should note the following constraints

1) CF2000 provides monitored outputs to drive fire and fault relays mounted in external equipment External relays should be suppressed If a non-suppressed relay is used then a diode can be connected to suppress any reverse EMF on the release of the relay which might cause the panel to malfunction

2) A 24V DC output is provided at the panel to make it easy to connect ancillary equipment Although the panel can supply a continuous quiescent load of up to 30mA BS5839 precludes this practice and any ancillary equipment you connect should only consume power in the alarm or fault mode to meet the requirements of BS5839

20

System Overview

Simple user interface

The main element of the user interface with CF2000 is a (60mm x 30mm visible area) display which provides comprehensive user information

As well as an LCD display providing full system status information the panel incorporates 32 traditional zone indication LEDs to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the systemIn addition there are a number of system status LEDs designed to give clear status information to non technical users

User configuration and maintenance facilities

CF2000 has comprehensive facilities for on site system configuration whereby the user can add or remove simple devices without the need for a service engineer to visit site For initial configuration or major system changes special PC configuration software is available enabling Cooper Fire Systems personnel to do this more efficiently than can be achieved using the system screen Exiting configurations can be uploaded to the PC so that changes can be made to the existing system rather than having to revert to initial filesDuring the yearly maintenance all terminal under main supply shall be verified

21

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 9: CF2000 User Manual

Compatible Equipment

Addressable Call Points

CBG370 Addressable call point - Flush 85(H) x 85(W) x 30(D)

CBG370S Addressable call point - Surface 85(H) x 85(W) x 53(D)

CBG370WP Weatherproof addressable call point 108(H) x 108(W) x 65(D)

Analogue Sensors

CAH330 Analogue heat detector 101 Dia x 43(D)

CAP320 Analogue optical smoke detector 101 Dia x 33(D)

CAI310 Analogue ionization smoke detector 101 Dia x 33(D)

CAPT340 Analogue photothermal dual detector 101 Dia x 43(D)

CAB300 Common mounting base 104 Dia x 22(D)

Addressable Interfaces

CSI350 Spur Isolator 85(H) x 145(W) x 58(D)

CIO351 3 Channel IO Unit 130(H) x 180(W) x 60(D)

CZMU352 Zone Monitor Unit 85(H) x 145(W) x 58(D)

CMIO353 230v Relay IO Unit 130(H) x 180(W) x 60(D)

CSC354 4 Way Sounder Controller 300(H) x 300(W) x 74(D)

CSUM355 Shop Unit Monitor 130(H) x 180(W) x 60(D)

Addressable Sounders and Beacons

CAS380 Loop Mounted Base Sounder 102 Dia x 40(D)

CAS381 Wall Sounder 105(H) x 105(W) x 95(D)

CAS381WP Wall Sounder - weatherproof 110(H) x 110(W) x 105(D)

CAB382 Loop Mounted Beacon 93 Dia x 53(D)

CASBB384 Loop Mounted Base SounderBeacon 115 Dia x 35(D)

CASB383 Wall SounderBeacon 106(H) x 106(W) x 91(D)

CASB383WP Wall SounderBeacon IP66 110(H) x 110(W) x 100(D)

Conventional Call Points

CBG375 Flush mounting call point 87(H) x 87(W) x 20(D)

CBG375S Surface mounting call point 87(H) x 87(W) x 53(D)

CBG376 Weatherproof surface call point 110(H) x 110(W) x 65(D)

Conventional Detectors

CPD320 Photoelectric smoke detector 101 Dia x 33(D)

CID310 Ionization smoke detector 101 Dia x 33(D)

CPT340 Combined photothermal detector 101 Dia x 43(D)

CFR330 Fast response heat detector 101 Dia x 43(D)

CMT360 Medium response heat detector 101 Dia x 43(D)

CHT390 High temperature heat detector 101 Dia x 43(D)

CDBB300 Common mounting base 104 Dia x 22(D)

Conventional Sounders

ACR 24V flush mounting electronic sounder 86(H) x 86(W) x 42(D)

CXBBR Surface mounting back box for ACR

SYR 24V low current sounder 105(H) x 105(W) x 95(D)

SQR Base sounder 112 Dia x 30(D)

ROLPRS Electronic sounder - shallow base for indoor applications 93 Dia x 75(D)

ROLPRD Electronic sounder - deep base (Weatherproof) 93 Dia x 105(D)

Conventional SounderBeacons

FLRLRD Combined sounderbeacon deep base 93 Dia x 92(D)

FLRLRS Combined sounderbeacon Shallow base 93 Dia x 121(D)

9

CPD320 Conventional Photoelectric Detector this is the most commonly used detector and is most suitable for detecting slow burning fires

The range of compatible detectors for the CF2000 system consists of the following

CPT340 Conventional Photothermal Detector this is a new addition to the Cooper Fire Systems range of detectors It is the ideal detector for a multi-use environment as it has an excellent response to smouldering and fast burning fires

CMT360 77degC Fixed Conventional Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

Compatible Equipment Conventional Devices

Model CID310 CPD320 CFR330 CMT360 CHT390 CPT340

Operating voltage

Standby current (max) 70microA

Start-up Current (max 20 seconds) 340microA

Alarm current (max) 20mA

Ambient Temperature (max) 45ordmC 60ordmC 75ordmC 75ordmC

Ambient Temperature (min)

Alarm temperature (static) 60ordmC 77ordmC

Heat detector class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 78g

Material

Colour

76g

15 to 30V dc

25mA

30microA

210microA NA

47mm 56mm

100mm

NA

NA

60ordmC

shy20ordmC

34mm

White

90ordmC

NA

0 to 95

43mm

A2R BS CS A2S

PCABS

10

CHT390 92degC Fixed Conventional Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CFR330 Rate of Rise A2R Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CDBB300 Conventional Detector Base

Compatible Equipment Conventional Devices

11

CAP320 Analogue Photoelectric Sensor this is the most commonly used sensors and is most suitable for detecting slow burning fires

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

The range of compatible sensors for the CF2000 system consists of the following

CAPT340 Analogue Photothermal Sensor this is a new addition to the Cooper Fire Systems range of sensors It is the ideal sensor for a multi-use environment as it has an excellent response to smouldering and fast burning fires Photothermal sensors can be programmed for thermal only operation at certain times of day

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Equipment Analogue Devices

Model CAI310 CAP320 CAH330 CAPT340

Operating voltage

Standby current (max)

Alarm current (max)

A1R 50ordmC

BS 65ordmC

CS 80ordmC

Ambient Temperature (min)

A1R 60ordmC

BS 77ordmC

CS 90ordmC

Heat sensor class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 76g 78g

Material

Colour

18 TO 30V dc

220microA

5mA

shy20ordmC

NAA1R BS CS

control panel

selectable

A2S

PCABS

0 to 95

34mm 43mm

NA

White

50ordmC60ordmCAmbient Temperature (max)

NA 60ordmCAlarm temperature (static)

47mm 56mm

100mm

12

CAH330 Analogue Heat SensorHeat sensors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions The CAH330 can be programmed to operate in A1RBS or CS mode of operation depending on the required application and sensitivity requirements

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

CAB300 Analogue Sensor Base

Compatible Equipment Analogue Devices

Short Circuit Isolators

Each of the sensors in his range contain an integral short circuit isolator which operates between the -VE COM IN terminal and the -VE COM OUT terminal The isolator operates in conjuction with the CF2000 Control Panel when a low parallel resistance fault of typically 200W is presented between the +VE and -VE of the loop wiring

Short Circuit Isolation Data

(Integral with each sensor)

Total Loop Resistance for correct

operation of short circuit isolator50Ugrave (max)

Continuous Current allowable through

isolator700mA (max)

Isolator Resistance in closed state 013Ugrave (max)

Leakage Current into direct short

circuit with isolator open13mA (max)

Parallel Fault Resistance to be seen

at the Control Panel for isolators to

open

200Ugrave (typ)

13

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezel

Compatible Sounders

A wide range of sounders are available to operate with CF2000All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

Conventional

CBG375

CBG375S

CBG376WP

14

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for the CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezelThe status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Sounders and Beacons

A wide range of loop powered sounders and beacons are available to operate with the CF2000 consisting of a combined sounder base with a maximum output of 95 dB(A) a standalone sounder with a maximum output of 100 dB(A) that is available in standard or weatherproof versions and a stand alone loop powered beaconFor applications where a discreet dedicated sounder is required a cover plate is available for the white base mounted sounder enabling it to be used as a stand alone wall or ceiling mounted sounderAll of these devices are fully programmable via the sophisticated CF2000 multi stage cause and effect programming facilities

All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

CBG370

CBG370S

CBG370WP

Analogue

15

Base sounder

The CAS380 has been designed specifically to complement the latest generation of Cooper Fire Systems soft addressed detectorsit consists of a first fix bracket and a main body which clips onto the bracket incorporating the sounder and a detector mounting base in a single composite assembly

After the body has been clicked into place and connected a sensor or front cover is then added to complete a very simple quick and neat installationThe cover enables the CAS380 to be used as a discreet stand alone wall or ceiling mounted deviceThe sounder base design incorporates a mechanism that can be activated if required to lock either the sensor or the cover into place to prevent unauthorised removal

Dedicated Stand alone sounders

Stand alone sounders are ideal for applications where greater sound outputs are required than can be achieved with a base sounder or for applications requiring a higher level of resilience or ingress protectionTwo different versions are available standard version and an IP66 rated version

CAS380

CAS381 CAS381WP

CAS380 with sensor fitted CAS380 with CASC fitted

Compatible Equipment

16

Interfaces

CF2000 has been designed to be suitable for a wide range of applications various interfaces have been developed to enable the simple integration of other fire systems or building control and safety systems The following devices are available

3 Channel IO device (CIO351)

CIO351 has 3 input channels and 3 output channels it is used to monitor up to three separate inputs from equipment such as sprinkler flow switches and also to provide 3 separately controlled volt free output contacts which are intended to be used to control external equipment such as air handling plant or access control systemsAll inputs and outputs operate completely independently of each other and can be programmed using the sophisticated cause and effect capabilities of CF2000 to operate either globally or in response to activation of specific devices or specific inputsInputs are monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalInputs are suitable for use as fire signal inputs such as from a sprinkler flow switch however they can also be used to monitor non fire inputs such as external keyswitchesOutputs are rated to switch a maximum of 1A resistive at 30V DCThe CIO351 is supplied in a surface mounting IP65 box

1 Channel IO device with mains rated switching capability (CMIO353)

CMIO353 is a single channel input output unit the output is capable of switching up to 1A at 230V ACCommonly used for applications such as door release controls and plant shut down signaling

The input is monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalThe input is suitable for use as a fire signal input such as from a sprinkler flow switch however it can also be used to monitor non fire inputs such as an external keyswitchThe CIO353 is supplied in a surface mounting IP65 box

CIO351 CMIO353

17

Zone monitor unit (CZMU352)

CZMU352 is designed to enable a zone of compatible conventional detectors and callpoints to be connected into the CF2000 loop it is compatible with up to 20 Cooper Fire Systems conventional detectors connected via CDBB300 basesPlease refer to local standards egBS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone CZMU352 fixes to a standard deep double gang back box and can be either surface or semi recess mounted When semi recessed only the front section protrudes giving a maximum 29mm depth

Shop unit Interface (CSUM355)

CSUM355 accepts a zone of conventional detectors plus an unlimited number of callpoints which can be connected to the same input as the detectors or a separate callpoint input if requiredIt also has a 24V 1A rated relay output and a facility to connect a power supply which can then be monitored for faultIn addition it has the facility to connect two circuits of conventional polarised sounders which are monitored by means of an end of line resistor and powered in alarm conditions from the external power supplyThe sounder circuits can be programmed to operate in pulsed continuous or time delayed mode

Please refer to local standards eg BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone The CSUM355 is supplied in a surface mounting IP65 box

Interfaces

CSUM355

CZUM352

18

(CZMU352)

Spur Isolator (CSI350)

CSI350 enables soft addressing to work when the loop contains spurs it controls the addressing operation so that when the system reaches a spur all devices on the spur are allocated an address before it continues addressing the loopThe device also incorporates a short circuit isolatorBecause each device contains a short circuit isolator only 1 is required at the start of each spur

CSI350 is mounted on a standard deep double gang back box (supplied)

Please refer to BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone

4 Way sounder circuit controller (CS354)

CSC354 provides power for 4 separately controllable conventional sounder circuits each circuit can be separately programmedCSC354 is designed to greatly simplify installation in applications where specialist sounders or beacons are required since it powers the sounders and allows full control of the sounder operation without having to wire the sounder back to the CF2000 control panel

A 4 way unit takes up a single address but each circuit can be independently controlledAn CSC354 unit requires a local un-switched 230V supply and incorporates a back up battery to 24 hours of standby operation followed by a minimum of 30 minutes of full alarm ringingA standby of 72 hours can be achieved at the expense of reduced load capability

Interfaces

CSI350

CSC354

19

Equipment Compatibility

SensorsLoop wired sensors must be of the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional detectors can be connected via an CZMU352 interface The connection of other detector types via an CZMU352 interface is not recommended

Call pointsLoop wired call points must be the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional callpoints can be connected via an CZMU352 interface The connection of other callpoint types via an CZMU352 interface is not recommended

SoundersLoop powered addressable sounders must be of the Cooper Fire Systems 300 series soft addressed analogue type

Conventional sounders can also be connected either to the conventional sounder circuits at the panel or to the loop via a CSC354 addressable sounder controller interface providing they meet the following1) They are suitable for operation between 18V and 28V2) They are polarised and suppressed3) The total alarm load is less than the rating of the panel Alarm Power Interface

Note It is possible to use devices outside these requirements if they are supplied with power from a separate source and switched via a suitable relay

Relay circuitsAdditional relays can be added to the CF2000 system by using either CMIO353 or CIO351 relay units

Relays Auto-dialers and auxiliary equipmentA wide variety of relays and other equipment can be connected to the CF2000 system but you should note the following constraints

1) CF2000 provides monitored outputs to drive fire and fault relays mounted in external equipment External relays should be suppressed If a non-suppressed relay is used then a diode can be connected to suppress any reverse EMF on the release of the relay which might cause the panel to malfunction

2) A 24V DC output is provided at the panel to make it easy to connect ancillary equipment Although the panel can supply a continuous quiescent load of up to 30mA BS5839 precludes this practice and any ancillary equipment you connect should only consume power in the alarm or fault mode to meet the requirements of BS5839

20

System Overview

Simple user interface

The main element of the user interface with CF2000 is a (60mm x 30mm visible area) display which provides comprehensive user information

As well as an LCD display providing full system status information the panel incorporates 32 traditional zone indication LEDs to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the systemIn addition there are a number of system status LEDs designed to give clear status information to non technical users

User configuration and maintenance facilities

CF2000 has comprehensive facilities for on site system configuration whereby the user can add or remove simple devices without the need for a service engineer to visit site For initial configuration or major system changes special PC configuration software is available enabling Cooper Fire Systems personnel to do this more efficiently than can be achieved using the system screen Exiting configurations can be uploaded to the PC so that changes can be made to the existing system rather than having to revert to initial filesDuring the yearly maintenance all terminal under main supply shall be verified

21

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 10: CF2000 User Manual

CPD320 Conventional Photoelectric Detector this is the most commonly used detector and is most suitable for detecting slow burning fires

The range of compatible detectors for the CF2000 system consists of the following

CPT340 Conventional Photothermal Detector this is a new addition to the Cooper Fire Systems range of detectors It is the ideal detector for a multi-use environment as it has an excellent response to smouldering and fast burning fires

CMT360 77degC Fixed Conventional Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

Compatible Equipment Conventional Devices

Model CID310 CPD320 CFR330 CMT360 CHT390 CPT340

Operating voltage

Standby current (max) 70microA

Start-up Current (max 20 seconds) 340microA

Alarm current (max) 20mA

Ambient Temperature (max) 45ordmC 60ordmC 75ordmC 75ordmC

Ambient Temperature (min)

Alarm temperature (static) 60ordmC 77ordmC

Heat detector class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 78g

Material

Colour

76g

15 to 30V dc

25mA

30microA

210microA NA

47mm 56mm

100mm

NA

NA

60ordmC

shy20ordmC

34mm

White

90ordmC

NA

0 to 95

43mm

A2R BS CS A2S

PCABS

10

CHT390 92degC Fixed Conventional Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CFR330 Rate of Rise A2R Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CDBB300 Conventional Detector Base

Compatible Equipment Conventional Devices

11

CAP320 Analogue Photoelectric Sensor this is the most commonly used sensors and is most suitable for detecting slow burning fires

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

The range of compatible sensors for the CF2000 system consists of the following

CAPT340 Analogue Photothermal Sensor this is a new addition to the Cooper Fire Systems range of sensors It is the ideal sensor for a multi-use environment as it has an excellent response to smouldering and fast burning fires Photothermal sensors can be programmed for thermal only operation at certain times of day

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Equipment Analogue Devices

Model CAI310 CAP320 CAH330 CAPT340

Operating voltage

Standby current (max)

Alarm current (max)

A1R 50ordmC

BS 65ordmC

CS 80ordmC

Ambient Temperature (min)

A1R 60ordmC

BS 77ordmC

CS 90ordmC

Heat sensor class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 76g 78g

Material

Colour

18 TO 30V dc

220microA

5mA

shy20ordmC

NAA1R BS CS

control panel

selectable

A2S

PCABS

0 to 95

34mm 43mm

NA

White

50ordmC60ordmCAmbient Temperature (max)

NA 60ordmCAlarm temperature (static)

47mm 56mm

100mm

12

CAH330 Analogue Heat SensorHeat sensors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions The CAH330 can be programmed to operate in A1RBS or CS mode of operation depending on the required application and sensitivity requirements

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

CAB300 Analogue Sensor Base

Compatible Equipment Analogue Devices

Short Circuit Isolators

Each of the sensors in his range contain an integral short circuit isolator which operates between the -VE COM IN terminal and the -VE COM OUT terminal The isolator operates in conjuction with the CF2000 Control Panel when a low parallel resistance fault of typically 200W is presented between the +VE and -VE of the loop wiring

Short Circuit Isolation Data

(Integral with each sensor)

Total Loop Resistance for correct

operation of short circuit isolator50Ugrave (max)

Continuous Current allowable through

isolator700mA (max)

Isolator Resistance in closed state 013Ugrave (max)

Leakage Current into direct short

circuit with isolator open13mA (max)

Parallel Fault Resistance to be seen

at the Control Panel for isolators to

open

200Ugrave (typ)

13

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezel

Compatible Sounders

A wide range of sounders are available to operate with CF2000All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

Conventional

CBG375

CBG375S

CBG376WP

14

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for the CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezelThe status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Sounders and Beacons

A wide range of loop powered sounders and beacons are available to operate with the CF2000 consisting of a combined sounder base with a maximum output of 95 dB(A) a standalone sounder with a maximum output of 100 dB(A) that is available in standard or weatherproof versions and a stand alone loop powered beaconFor applications where a discreet dedicated sounder is required a cover plate is available for the white base mounted sounder enabling it to be used as a stand alone wall or ceiling mounted sounderAll of these devices are fully programmable via the sophisticated CF2000 multi stage cause and effect programming facilities

All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

CBG370

CBG370S

CBG370WP

Analogue

15

Base sounder

The CAS380 has been designed specifically to complement the latest generation of Cooper Fire Systems soft addressed detectorsit consists of a first fix bracket and a main body which clips onto the bracket incorporating the sounder and a detector mounting base in a single composite assembly

After the body has been clicked into place and connected a sensor or front cover is then added to complete a very simple quick and neat installationThe cover enables the CAS380 to be used as a discreet stand alone wall or ceiling mounted deviceThe sounder base design incorporates a mechanism that can be activated if required to lock either the sensor or the cover into place to prevent unauthorised removal

Dedicated Stand alone sounders

Stand alone sounders are ideal for applications where greater sound outputs are required than can be achieved with a base sounder or for applications requiring a higher level of resilience or ingress protectionTwo different versions are available standard version and an IP66 rated version

CAS380

CAS381 CAS381WP

CAS380 with sensor fitted CAS380 with CASC fitted

Compatible Equipment

16

Interfaces

CF2000 has been designed to be suitable for a wide range of applications various interfaces have been developed to enable the simple integration of other fire systems or building control and safety systems The following devices are available

3 Channel IO device (CIO351)

CIO351 has 3 input channels and 3 output channels it is used to monitor up to three separate inputs from equipment such as sprinkler flow switches and also to provide 3 separately controlled volt free output contacts which are intended to be used to control external equipment such as air handling plant or access control systemsAll inputs and outputs operate completely independently of each other and can be programmed using the sophisticated cause and effect capabilities of CF2000 to operate either globally or in response to activation of specific devices or specific inputsInputs are monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalInputs are suitable for use as fire signal inputs such as from a sprinkler flow switch however they can also be used to monitor non fire inputs such as external keyswitchesOutputs are rated to switch a maximum of 1A resistive at 30V DCThe CIO351 is supplied in a surface mounting IP65 box

1 Channel IO device with mains rated switching capability (CMIO353)

CMIO353 is a single channel input output unit the output is capable of switching up to 1A at 230V ACCommonly used for applications such as door release controls and plant shut down signaling

The input is monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalThe input is suitable for use as a fire signal input such as from a sprinkler flow switch however it can also be used to monitor non fire inputs such as an external keyswitchThe CIO353 is supplied in a surface mounting IP65 box

CIO351 CMIO353

17

Zone monitor unit (CZMU352)

CZMU352 is designed to enable a zone of compatible conventional detectors and callpoints to be connected into the CF2000 loop it is compatible with up to 20 Cooper Fire Systems conventional detectors connected via CDBB300 basesPlease refer to local standards egBS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone CZMU352 fixes to a standard deep double gang back box and can be either surface or semi recess mounted When semi recessed only the front section protrudes giving a maximum 29mm depth

Shop unit Interface (CSUM355)

CSUM355 accepts a zone of conventional detectors plus an unlimited number of callpoints which can be connected to the same input as the detectors or a separate callpoint input if requiredIt also has a 24V 1A rated relay output and a facility to connect a power supply which can then be monitored for faultIn addition it has the facility to connect two circuits of conventional polarised sounders which are monitored by means of an end of line resistor and powered in alarm conditions from the external power supplyThe sounder circuits can be programmed to operate in pulsed continuous or time delayed mode

Please refer to local standards eg BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone The CSUM355 is supplied in a surface mounting IP65 box

Interfaces

CSUM355

CZUM352

18

(CZMU352)

Spur Isolator (CSI350)

CSI350 enables soft addressing to work when the loop contains spurs it controls the addressing operation so that when the system reaches a spur all devices on the spur are allocated an address before it continues addressing the loopThe device also incorporates a short circuit isolatorBecause each device contains a short circuit isolator only 1 is required at the start of each spur

CSI350 is mounted on a standard deep double gang back box (supplied)

Please refer to BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone

4 Way sounder circuit controller (CS354)

CSC354 provides power for 4 separately controllable conventional sounder circuits each circuit can be separately programmedCSC354 is designed to greatly simplify installation in applications where specialist sounders or beacons are required since it powers the sounders and allows full control of the sounder operation without having to wire the sounder back to the CF2000 control panel

A 4 way unit takes up a single address but each circuit can be independently controlledAn CSC354 unit requires a local un-switched 230V supply and incorporates a back up battery to 24 hours of standby operation followed by a minimum of 30 minutes of full alarm ringingA standby of 72 hours can be achieved at the expense of reduced load capability

Interfaces

CSI350

CSC354

19

Equipment Compatibility

SensorsLoop wired sensors must be of the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional detectors can be connected via an CZMU352 interface The connection of other detector types via an CZMU352 interface is not recommended

Call pointsLoop wired call points must be the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional callpoints can be connected via an CZMU352 interface The connection of other callpoint types via an CZMU352 interface is not recommended

SoundersLoop powered addressable sounders must be of the Cooper Fire Systems 300 series soft addressed analogue type

Conventional sounders can also be connected either to the conventional sounder circuits at the panel or to the loop via a CSC354 addressable sounder controller interface providing they meet the following1) They are suitable for operation between 18V and 28V2) They are polarised and suppressed3) The total alarm load is less than the rating of the panel Alarm Power Interface

Note It is possible to use devices outside these requirements if they are supplied with power from a separate source and switched via a suitable relay

Relay circuitsAdditional relays can be added to the CF2000 system by using either CMIO353 or CIO351 relay units

Relays Auto-dialers and auxiliary equipmentA wide variety of relays and other equipment can be connected to the CF2000 system but you should note the following constraints

1) CF2000 provides monitored outputs to drive fire and fault relays mounted in external equipment External relays should be suppressed If a non-suppressed relay is used then a diode can be connected to suppress any reverse EMF on the release of the relay which might cause the panel to malfunction

2) A 24V DC output is provided at the panel to make it easy to connect ancillary equipment Although the panel can supply a continuous quiescent load of up to 30mA BS5839 precludes this practice and any ancillary equipment you connect should only consume power in the alarm or fault mode to meet the requirements of BS5839

20

System Overview

Simple user interface

The main element of the user interface with CF2000 is a (60mm x 30mm visible area) display which provides comprehensive user information

As well as an LCD display providing full system status information the panel incorporates 32 traditional zone indication LEDs to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the systemIn addition there are a number of system status LEDs designed to give clear status information to non technical users

User configuration and maintenance facilities

CF2000 has comprehensive facilities for on site system configuration whereby the user can add or remove simple devices without the need for a service engineer to visit site For initial configuration or major system changes special PC configuration software is available enabling Cooper Fire Systems personnel to do this more efficiently than can be achieved using the system screen Exiting configurations can be uploaded to the PC so that changes can be made to the existing system rather than having to revert to initial filesDuring the yearly maintenance all terminal under main supply shall be verified

21

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 11: CF2000 User Manual

CHT390 92degC Fixed Conventional Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CFR330 Rate of Rise A2R Heat DetectorHeat detectors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions

CDBB300 Conventional Detector Base

Compatible Equipment Conventional Devices

11

CAP320 Analogue Photoelectric Sensor this is the most commonly used sensors and is most suitable for detecting slow burning fires

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

The range of compatible sensors for the CF2000 system consists of the following

CAPT340 Analogue Photothermal Sensor this is a new addition to the Cooper Fire Systems range of sensors It is the ideal sensor for a multi-use environment as it has an excellent response to smouldering and fast burning fires Photothermal sensors can be programmed for thermal only operation at certain times of day

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Equipment Analogue Devices

Model CAI310 CAP320 CAH330 CAPT340

Operating voltage

Standby current (max)

Alarm current (max)

A1R 50ordmC

BS 65ordmC

CS 80ordmC

Ambient Temperature (min)

A1R 60ordmC

BS 77ordmC

CS 90ordmC

Heat sensor class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 76g 78g

Material

Colour

18 TO 30V dc

220microA

5mA

shy20ordmC

NAA1R BS CS

control panel

selectable

A2S

PCABS

0 to 95

34mm 43mm

NA

White

50ordmC60ordmCAmbient Temperature (max)

NA 60ordmCAlarm temperature (static)

47mm 56mm

100mm

12

CAH330 Analogue Heat SensorHeat sensors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions The CAH330 can be programmed to operate in A1RBS or CS mode of operation depending on the required application and sensitivity requirements

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

CAB300 Analogue Sensor Base

Compatible Equipment Analogue Devices

Short Circuit Isolators

Each of the sensors in his range contain an integral short circuit isolator which operates between the -VE COM IN terminal and the -VE COM OUT terminal The isolator operates in conjuction with the CF2000 Control Panel when a low parallel resistance fault of typically 200W is presented between the +VE and -VE of the loop wiring

Short Circuit Isolation Data

(Integral with each sensor)

Total Loop Resistance for correct

operation of short circuit isolator50Ugrave (max)

Continuous Current allowable through

isolator700mA (max)

Isolator Resistance in closed state 013Ugrave (max)

Leakage Current into direct short

circuit with isolator open13mA (max)

Parallel Fault Resistance to be seen

at the Control Panel for isolators to

open

200Ugrave (typ)

13

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezel

Compatible Sounders

A wide range of sounders are available to operate with CF2000All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

Conventional

CBG375

CBG375S

CBG376WP

14

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for the CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezelThe status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Sounders and Beacons

A wide range of loop powered sounders and beacons are available to operate with the CF2000 consisting of a combined sounder base with a maximum output of 95 dB(A) a standalone sounder with a maximum output of 100 dB(A) that is available in standard or weatherproof versions and a stand alone loop powered beaconFor applications where a discreet dedicated sounder is required a cover plate is available for the white base mounted sounder enabling it to be used as a stand alone wall or ceiling mounted sounderAll of these devices are fully programmable via the sophisticated CF2000 multi stage cause and effect programming facilities

All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

CBG370

CBG370S

CBG370WP

Analogue

15

Base sounder

The CAS380 has been designed specifically to complement the latest generation of Cooper Fire Systems soft addressed detectorsit consists of a first fix bracket and a main body which clips onto the bracket incorporating the sounder and a detector mounting base in a single composite assembly

After the body has been clicked into place and connected a sensor or front cover is then added to complete a very simple quick and neat installationThe cover enables the CAS380 to be used as a discreet stand alone wall or ceiling mounted deviceThe sounder base design incorporates a mechanism that can be activated if required to lock either the sensor or the cover into place to prevent unauthorised removal

Dedicated Stand alone sounders

Stand alone sounders are ideal for applications where greater sound outputs are required than can be achieved with a base sounder or for applications requiring a higher level of resilience or ingress protectionTwo different versions are available standard version and an IP66 rated version

CAS380

CAS381 CAS381WP

CAS380 with sensor fitted CAS380 with CASC fitted

Compatible Equipment

16

Interfaces

CF2000 has been designed to be suitable for a wide range of applications various interfaces have been developed to enable the simple integration of other fire systems or building control and safety systems The following devices are available

3 Channel IO device (CIO351)

CIO351 has 3 input channels and 3 output channels it is used to monitor up to three separate inputs from equipment such as sprinkler flow switches and also to provide 3 separately controlled volt free output contacts which are intended to be used to control external equipment such as air handling plant or access control systemsAll inputs and outputs operate completely independently of each other and can be programmed using the sophisticated cause and effect capabilities of CF2000 to operate either globally or in response to activation of specific devices or specific inputsInputs are monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalInputs are suitable for use as fire signal inputs such as from a sprinkler flow switch however they can also be used to monitor non fire inputs such as external keyswitchesOutputs are rated to switch a maximum of 1A resistive at 30V DCThe CIO351 is supplied in a surface mounting IP65 box

1 Channel IO device with mains rated switching capability (CMIO353)

CMIO353 is a single channel input output unit the output is capable of switching up to 1A at 230V ACCommonly used for applications such as door release controls and plant shut down signaling

The input is monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalThe input is suitable for use as a fire signal input such as from a sprinkler flow switch however it can also be used to monitor non fire inputs such as an external keyswitchThe CIO353 is supplied in a surface mounting IP65 box

CIO351 CMIO353

17

Zone monitor unit (CZMU352)

CZMU352 is designed to enable a zone of compatible conventional detectors and callpoints to be connected into the CF2000 loop it is compatible with up to 20 Cooper Fire Systems conventional detectors connected via CDBB300 basesPlease refer to local standards egBS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone CZMU352 fixes to a standard deep double gang back box and can be either surface or semi recess mounted When semi recessed only the front section protrudes giving a maximum 29mm depth

Shop unit Interface (CSUM355)

CSUM355 accepts a zone of conventional detectors plus an unlimited number of callpoints which can be connected to the same input as the detectors or a separate callpoint input if requiredIt also has a 24V 1A rated relay output and a facility to connect a power supply which can then be monitored for faultIn addition it has the facility to connect two circuits of conventional polarised sounders which are monitored by means of an end of line resistor and powered in alarm conditions from the external power supplyThe sounder circuits can be programmed to operate in pulsed continuous or time delayed mode

Please refer to local standards eg BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone The CSUM355 is supplied in a surface mounting IP65 box

Interfaces

CSUM355

CZUM352

18

(CZMU352)

Spur Isolator (CSI350)

CSI350 enables soft addressing to work when the loop contains spurs it controls the addressing operation so that when the system reaches a spur all devices on the spur are allocated an address before it continues addressing the loopThe device also incorporates a short circuit isolatorBecause each device contains a short circuit isolator only 1 is required at the start of each spur

CSI350 is mounted on a standard deep double gang back box (supplied)

Please refer to BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone

4 Way sounder circuit controller (CS354)

CSC354 provides power for 4 separately controllable conventional sounder circuits each circuit can be separately programmedCSC354 is designed to greatly simplify installation in applications where specialist sounders or beacons are required since it powers the sounders and allows full control of the sounder operation without having to wire the sounder back to the CF2000 control panel

A 4 way unit takes up a single address but each circuit can be independently controlledAn CSC354 unit requires a local un-switched 230V supply and incorporates a back up battery to 24 hours of standby operation followed by a minimum of 30 minutes of full alarm ringingA standby of 72 hours can be achieved at the expense of reduced load capability

Interfaces

CSI350

CSC354

19

Equipment Compatibility

SensorsLoop wired sensors must be of the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional detectors can be connected via an CZMU352 interface The connection of other detector types via an CZMU352 interface is not recommended

Call pointsLoop wired call points must be the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional callpoints can be connected via an CZMU352 interface The connection of other callpoint types via an CZMU352 interface is not recommended

SoundersLoop powered addressable sounders must be of the Cooper Fire Systems 300 series soft addressed analogue type

Conventional sounders can also be connected either to the conventional sounder circuits at the panel or to the loop via a CSC354 addressable sounder controller interface providing they meet the following1) They are suitable for operation between 18V and 28V2) They are polarised and suppressed3) The total alarm load is less than the rating of the panel Alarm Power Interface

Note It is possible to use devices outside these requirements if they are supplied with power from a separate source and switched via a suitable relay

Relay circuitsAdditional relays can be added to the CF2000 system by using either CMIO353 or CIO351 relay units

Relays Auto-dialers and auxiliary equipmentA wide variety of relays and other equipment can be connected to the CF2000 system but you should note the following constraints

1) CF2000 provides monitored outputs to drive fire and fault relays mounted in external equipment External relays should be suppressed If a non-suppressed relay is used then a diode can be connected to suppress any reverse EMF on the release of the relay which might cause the panel to malfunction

2) A 24V DC output is provided at the panel to make it easy to connect ancillary equipment Although the panel can supply a continuous quiescent load of up to 30mA BS5839 precludes this practice and any ancillary equipment you connect should only consume power in the alarm or fault mode to meet the requirements of BS5839

20

System Overview

Simple user interface

The main element of the user interface with CF2000 is a (60mm x 30mm visible area) display which provides comprehensive user information

As well as an LCD display providing full system status information the panel incorporates 32 traditional zone indication LEDs to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the systemIn addition there are a number of system status LEDs designed to give clear status information to non technical users

User configuration and maintenance facilities

CF2000 has comprehensive facilities for on site system configuration whereby the user can add or remove simple devices without the need for a service engineer to visit site For initial configuration or major system changes special PC configuration software is available enabling Cooper Fire Systems personnel to do this more efficiently than can be achieved using the system screen Exiting configurations can be uploaded to the PC so that changes can be made to the existing system rather than having to revert to initial filesDuring the yearly maintenance all terminal under main supply shall be verified

21

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 12: CF2000 User Manual

CAP320 Analogue Photoelectric Sensor this is the most commonly used sensors and is most suitable for detecting slow burning fires

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

The range of compatible sensors for the CF2000 system consists of the following

CAPT340 Analogue Photothermal Sensor this is a new addition to the Cooper Fire Systems range of sensors It is the ideal sensor for a multi-use environment as it has an excellent response to smouldering and fast burning fires Photothermal sensors can be programmed for thermal only operation at certain times of day

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Equipment Analogue Devices

Model CAI310 CAP320 CAH330 CAPT340

Operating voltage

Standby current (max)

Alarm current (max)

A1R 50ordmC

BS 65ordmC

CS 80ordmC

Ambient Temperature (min)

A1R 60ordmC

BS 77ordmC

CS 90ordmC

Heat sensor class

as defined by EN54-52000

Radioactive materialstrength Am 185KBq

Relative humidity (non cond)

Height (wo base)

Height (with base)

Diameter

Weight (wo base) 86g 78g 76g 78g

Material

Colour

18 TO 30V dc

220microA

5mA

shy20ordmC

NAA1R BS CS

control panel

selectable

A2S

PCABS

0 to 95

34mm 43mm

NA

White

50ordmC60ordmCAmbient Temperature (max)

NA 60ordmCAlarm temperature (static)

47mm 56mm

100mm

12

CAH330 Analogue Heat SensorHeat sensors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions The CAH330 can be programmed to operate in A1RBS or CS mode of operation depending on the required application and sensitivity requirements

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

CAB300 Analogue Sensor Base

Compatible Equipment Analogue Devices

Short Circuit Isolators

Each of the sensors in his range contain an integral short circuit isolator which operates between the -VE COM IN terminal and the -VE COM OUT terminal The isolator operates in conjuction with the CF2000 Control Panel when a low parallel resistance fault of typically 200W is presented between the +VE and -VE of the loop wiring

Short Circuit Isolation Data

(Integral with each sensor)

Total Loop Resistance for correct

operation of short circuit isolator50Ugrave (max)

Continuous Current allowable through

isolator700mA (max)

Isolator Resistance in closed state 013Ugrave (max)

Leakage Current into direct short

circuit with isolator open13mA (max)

Parallel Fault Resistance to be seen

at the Control Panel for isolators to

open

200Ugrave (typ)

13

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezel

Compatible Sounders

A wide range of sounders are available to operate with CF2000All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

Conventional

CBG375

CBG375S

CBG376WP

14

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for the CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezelThe status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Sounders and Beacons

A wide range of loop powered sounders and beacons are available to operate with the CF2000 consisting of a combined sounder base with a maximum output of 95 dB(A) a standalone sounder with a maximum output of 100 dB(A) that is available in standard or weatherproof versions and a stand alone loop powered beaconFor applications where a discreet dedicated sounder is required a cover plate is available for the white base mounted sounder enabling it to be used as a stand alone wall or ceiling mounted sounderAll of these devices are fully programmable via the sophisticated CF2000 multi stage cause and effect programming facilities

All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

CBG370

CBG370S

CBG370WP

Analogue

15

Base sounder

The CAS380 has been designed specifically to complement the latest generation of Cooper Fire Systems soft addressed detectorsit consists of a first fix bracket and a main body which clips onto the bracket incorporating the sounder and a detector mounting base in a single composite assembly

After the body has been clicked into place and connected a sensor or front cover is then added to complete a very simple quick and neat installationThe cover enables the CAS380 to be used as a discreet stand alone wall or ceiling mounted deviceThe sounder base design incorporates a mechanism that can be activated if required to lock either the sensor or the cover into place to prevent unauthorised removal

Dedicated Stand alone sounders

Stand alone sounders are ideal for applications where greater sound outputs are required than can be achieved with a base sounder or for applications requiring a higher level of resilience or ingress protectionTwo different versions are available standard version and an IP66 rated version

CAS380

CAS381 CAS381WP

CAS380 with sensor fitted CAS380 with CASC fitted

Compatible Equipment

16

Interfaces

CF2000 has been designed to be suitable for a wide range of applications various interfaces have been developed to enable the simple integration of other fire systems or building control and safety systems The following devices are available

3 Channel IO device (CIO351)

CIO351 has 3 input channels and 3 output channels it is used to monitor up to three separate inputs from equipment such as sprinkler flow switches and also to provide 3 separately controlled volt free output contacts which are intended to be used to control external equipment such as air handling plant or access control systemsAll inputs and outputs operate completely independently of each other and can be programmed using the sophisticated cause and effect capabilities of CF2000 to operate either globally or in response to activation of specific devices or specific inputsInputs are monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalInputs are suitable for use as fire signal inputs such as from a sprinkler flow switch however they can also be used to monitor non fire inputs such as external keyswitchesOutputs are rated to switch a maximum of 1A resistive at 30V DCThe CIO351 is supplied in a surface mounting IP65 box

1 Channel IO device with mains rated switching capability (CMIO353)

CMIO353 is a single channel input output unit the output is capable of switching up to 1A at 230V ACCommonly used for applications such as door release controls and plant shut down signaling

The input is monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalThe input is suitable for use as a fire signal input such as from a sprinkler flow switch however it can also be used to monitor non fire inputs such as an external keyswitchThe CIO353 is supplied in a surface mounting IP65 box

CIO351 CMIO353

17

Zone monitor unit (CZMU352)

CZMU352 is designed to enable a zone of compatible conventional detectors and callpoints to be connected into the CF2000 loop it is compatible with up to 20 Cooper Fire Systems conventional detectors connected via CDBB300 basesPlease refer to local standards egBS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone CZMU352 fixes to a standard deep double gang back box and can be either surface or semi recess mounted When semi recessed only the front section protrudes giving a maximum 29mm depth

Shop unit Interface (CSUM355)

CSUM355 accepts a zone of conventional detectors plus an unlimited number of callpoints which can be connected to the same input as the detectors or a separate callpoint input if requiredIt also has a 24V 1A rated relay output and a facility to connect a power supply which can then be monitored for faultIn addition it has the facility to connect two circuits of conventional polarised sounders which are monitored by means of an end of line resistor and powered in alarm conditions from the external power supplyThe sounder circuits can be programmed to operate in pulsed continuous or time delayed mode

Please refer to local standards eg BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone The CSUM355 is supplied in a surface mounting IP65 box

Interfaces

CSUM355

CZUM352

18

(CZMU352)

Spur Isolator (CSI350)

CSI350 enables soft addressing to work when the loop contains spurs it controls the addressing operation so that when the system reaches a spur all devices on the spur are allocated an address before it continues addressing the loopThe device also incorporates a short circuit isolatorBecause each device contains a short circuit isolator only 1 is required at the start of each spur

CSI350 is mounted on a standard deep double gang back box (supplied)

Please refer to BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone

4 Way sounder circuit controller (CS354)

CSC354 provides power for 4 separately controllable conventional sounder circuits each circuit can be separately programmedCSC354 is designed to greatly simplify installation in applications where specialist sounders or beacons are required since it powers the sounders and allows full control of the sounder operation without having to wire the sounder back to the CF2000 control panel

A 4 way unit takes up a single address but each circuit can be independently controlledAn CSC354 unit requires a local un-switched 230V supply and incorporates a back up battery to 24 hours of standby operation followed by a minimum of 30 minutes of full alarm ringingA standby of 72 hours can be achieved at the expense of reduced load capability

Interfaces

CSI350

CSC354

19

Equipment Compatibility

SensorsLoop wired sensors must be of the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional detectors can be connected via an CZMU352 interface The connection of other detector types via an CZMU352 interface is not recommended

Call pointsLoop wired call points must be the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional callpoints can be connected via an CZMU352 interface The connection of other callpoint types via an CZMU352 interface is not recommended

SoundersLoop powered addressable sounders must be of the Cooper Fire Systems 300 series soft addressed analogue type

Conventional sounders can also be connected either to the conventional sounder circuits at the panel or to the loop via a CSC354 addressable sounder controller interface providing they meet the following1) They are suitable for operation between 18V and 28V2) They are polarised and suppressed3) The total alarm load is less than the rating of the panel Alarm Power Interface

Note It is possible to use devices outside these requirements if they are supplied with power from a separate source and switched via a suitable relay

Relay circuitsAdditional relays can be added to the CF2000 system by using either CMIO353 or CIO351 relay units

Relays Auto-dialers and auxiliary equipmentA wide variety of relays and other equipment can be connected to the CF2000 system but you should note the following constraints

1) CF2000 provides monitored outputs to drive fire and fault relays mounted in external equipment External relays should be suppressed If a non-suppressed relay is used then a diode can be connected to suppress any reverse EMF on the release of the relay which might cause the panel to malfunction

2) A 24V DC output is provided at the panel to make it easy to connect ancillary equipment Although the panel can supply a continuous quiescent load of up to 30mA BS5839 precludes this practice and any ancillary equipment you connect should only consume power in the alarm or fault mode to meet the requirements of BS5839

20

System Overview

Simple user interface

The main element of the user interface with CF2000 is a (60mm x 30mm visible area) display which provides comprehensive user information

As well as an LCD display providing full system status information the panel incorporates 32 traditional zone indication LEDs to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the systemIn addition there are a number of system status LEDs designed to give clear status information to non technical users

User configuration and maintenance facilities

CF2000 has comprehensive facilities for on site system configuration whereby the user can add or remove simple devices without the need for a service engineer to visit site For initial configuration or major system changes special PC configuration software is available enabling Cooper Fire Systems personnel to do this more efficiently than can be achieved using the system screen Exiting configurations can be uploaded to the PC so that changes can be made to the existing system rather than having to revert to initial filesDuring the yearly maintenance all terminal under main supply shall be verified

21

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 13: CF2000 User Manual

CAH330 Analogue Heat SensorHeat sensors are suitable for dusty environments or environments where smoke is likely to be present under normal operating conditions The CAH330 can be programmed to operate in A1RBS or CS mode of operation depending on the required application and sensitivity requirements

The status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

CAB300 Analogue Sensor Base

Compatible Equipment Analogue Devices

Short Circuit Isolators

Each of the sensors in his range contain an integral short circuit isolator which operates between the -VE COM IN terminal and the -VE COM OUT terminal The isolator operates in conjuction with the CF2000 Control Panel when a low parallel resistance fault of typically 200W is presented between the +VE and -VE of the loop wiring

Short Circuit Isolation Data

(Integral with each sensor)

Total Loop Resistance for correct

operation of short circuit isolator50Ugrave (max)

Continuous Current allowable through

isolator700mA (max)

Isolator Resistance in closed state 013Ugrave (max)

Leakage Current into direct short

circuit with isolator open13mA (max)

Parallel Fault Resistance to be seen

at the Control Panel for isolators to

open

200Ugrave (typ)

13

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezel

Compatible Sounders

A wide range of sounders are available to operate with CF2000All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

Conventional

CBG375

CBG375S

CBG376WP

14

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for the CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezelThe status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Sounders and Beacons

A wide range of loop powered sounders and beacons are available to operate with the CF2000 consisting of a combined sounder base with a maximum output of 95 dB(A) a standalone sounder with a maximum output of 100 dB(A) that is available in standard or weatherproof versions and a stand alone loop powered beaconFor applications where a discreet dedicated sounder is required a cover plate is available for the white base mounted sounder enabling it to be used as a stand alone wall or ceiling mounted sounderAll of these devices are fully programmable via the sophisticated CF2000 multi stage cause and effect programming facilities

All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

CBG370

CBG370S

CBG370WP

Analogue

15

Base sounder

The CAS380 has been designed specifically to complement the latest generation of Cooper Fire Systems soft addressed detectorsit consists of a first fix bracket and a main body which clips onto the bracket incorporating the sounder and a detector mounting base in a single composite assembly

After the body has been clicked into place and connected a sensor or front cover is then added to complete a very simple quick and neat installationThe cover enables the CAS380 to be used as a discreet stand alone wall or ceiling mounted deviceThe sounder base design incorporates a mechanism that can be activated if required to lock either the sensor or the cover into place to prevent unauthorised removal

Dedicated Stand alone sounders

Stand alone sounders are ideal for applications where greater sound outputs are required than can be achieved with a base sounder or for applications requiring a higher level of resilience or ingress protectionTwo different versions are available standard version and an IP66 rated version

CAS380

CAS381 CAS381WP

CAS380 with sensor fitted CAS380 with CASC fitted

Compatible Equipment

16

Interfaces

CF2000 has been designed to be suitable for a wide range of applications various interfaces have been developed to enable the simple integration of other fire systems or building control and safety systems The following devices are available

3 Channel IO device (CIO351)

CIO351 has 3 input channels and 3 output channels it is used to monitor up to three separate inputs from equipment such as sprinkler flow switches and also to provide 3 separately controlled volt free output contacts which are intended to be used to control external equipment such as air handling plant or access control systemsAll inputs and outputs operate completely independently of each other and can be programmed using the sophisticated cause and effect capabilities of CF2000 to operate either globally or in response to activation of specific devices or specific inputsInputs are monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalInputs are suitable for use as fire signal inputs such as from a sprinkler flow switch however they can also be used to monitor non fire inputs such as external keyswitchesOutputs are rated to switch a maximum of 1A resistive at 30V DCThe CIO351 is supplied in a surface mounting IP65 box

1 Channel IO device with mains rated switching capability (CMIO353)

CMIO353 is a single channel input output unit the output is capable of switching up to 1A at 230V ACCommonly used for applications such as door release controls and plant shut down signaling

The input is monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalThe input is suitable for use as a fire signal input such as from a sprinkler flow switch however it can also be used to monitor non fire inputs such as an external keyswitchThe CIO353 is supplied in a surface mounting IP65 box

CIO351 CMIO353

17

Zone monitor unit (CZMU352)

CZMU352 is designed to enable a zone of compatible conventional detectors and callpoints to be connected into the CF2000 loop it is compatible with up to 20 Cooper Fire Systems conventional detectors connected via CDBB300 basesPlease refer to local standards egBS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone CZMU352 fixes to a standard deep double gang back box and can be either surface or semi recess mounted When semi recessed only the front section protrudes giving a maximum 29mm depth

Shop unit Interface (CSUM355)

CSUM355 accepts a zone of conventional detectors plus an unlimited number of callpoints which can be connected to the same input as the detectors or a separate callpoint input if requiredIt also has a 24V 1A rated relay output and a facility to connect a power supply which can then be monitored for faultIn addition it has the facility to connect two circuits of conventional polarised sounders which are monitored by means of an end of line resistor and powered in alarm conditions from the external power supplyThe sounder circuits can be programmed to operate in pulsed continuous or time delayed mode

Please refer to local standards eg BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone The CSUM355 is supplied in a surface mounting IP65 box

Interfaces

CSUM355

CZUM352

18

(CZMU352)

Spur Isolator (CSI350)

CSI350 enables soft addressing to work when the loop contains spurs it controls the addressing operation so that when the system reaches a spur all devices on the spur are allocated an address before it continues addressing the loopThe device also incorporates a short circuit isolatorBecause each device contains a short circuit isolator only 1 is required at the start of each spur

CSI350 is mounted on a standard deep double gang back box (supplied)

Please refer to BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone

4 Way sounder circuit controller (CS354)

CSC354 provides power for 4 separately controllable conventional sounder circuits each circuit can be separately programmedCSC354 is designed to greatly simplify installation in applications where specialist sounders or beacons are required since it powers the sounders and allows full control of the sounder operation without having to wire the sounder back to the CF2000 control panel

A 4 way unit takes up a single address but each circuit can be independently controlledAn CSC354 unit requires a local un-switched 230V supply and incorporates a back up battery to 24 hours of standby operation followed by a minimum of 30 minutes of full alarm ringingA standby of 72 hours can be achieved at the expense of reduced load capability

Interfaces

CSI350

CSC354

19

Equipment Compatibility

SensorsLoop wired sensors must be of the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional detectors can be connected via an CZMU352 interface The connection of other detector types via an CZMU352 interface is not recommended

Call pointsLoop wired call points must be the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional callpoints can be connected via an CZMU352 interface The connection of other callpoint types via an CZMU352 interface is not recommended

SoundersLoop powered addressable sounders must be of the Cooper Fire Systems 300 series soft addressed analogue type

Conventional sounders can also be connected either to the conventional sounder circuits at the panel or to the loop via a CSC354 addressable sounder controller interface providing they meet the following1) They are suitable for operation between 18V and 28V2) They are polarised and suppressed3) The total alarm load is less than the rating of the panel Alarm Power Interface

Note It is possible to use devices outside these requirements if they are supplied with power from a separate source and switched via a suitable relay

Relay circuitsAdditional relays can be added to the CF2000 system by using either CMIO353 or CIO351 relay units

Relays Auto-dialers and auxiliary equipmentA wide variety of relays and other equipment can be connected to the CF2000 system but you should note the following constraints

1) CF2000 provides monitored outputs to drive fire and fault relays mounted in external equipment External relays should be suppressed If a non-suppressed relay is used then a diode can be connected to suppress any reverse EMF on the release of the relay which might cause the panel to malfunction

2) A 24V DC output is provided at the panel to make it easy to connect ancillary equipment Although the panel can supply a continuous quiescent load of up to 30mA BS5839 precludes this practice and any ancillary equipment you connect should only consume power in the alarm or fault mode to meet the requirements of BS5839

20

System Overview

Simple user interface

The main element of the user interface with CF2000 is a (60mm x 30mm visible area) display which provides comprehensive user information

As well as an LCD display providing full system status information the panel incorporates 32 traditional zone indication LEDs to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the systemIn addition there are a number of system status LEDs designed to give clear status information to non technical users

User configuration and maintenance facilities

CF2000 has comprehensive facilities for on site system configuration whereby the user can add or remove simple devices without the need for a service engineer to visit site For initial configuration or major system changes special PC configuration software is available enabling Cooper Fire Systems personnel to do this more efficiently than can be achieved using the system screen Exiting configurations can be uploaded to the PC so that changes can be made to the existing system rather than having to revert to initial filesDuring the yearly maintenance all terminal under main supply shall be verified

21

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 14: CF2000 User Manual

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezel

Compatible Sounders

A wide range of sounders are available to operate with CF2000All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

Conventional

CBG375

CBG375S

CBG376WP

14

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for the CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezelThe status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Sounders and Beacons

A wide range of loop powered sounders and beacons are available to operate with the CF2000 consisting of a combined sounder base with a maximum output of 95 dB(A) a standalone sounder with a maximum output of 100 dB(A) that is available in standard or weatherproof versions and a stand alone loop powered beaconFor applications where a discreet dedicated sounder is required a cover plate is available for the white base mounted sounder enabling it to be used as a stand alone wall or ceiling mounted sounderAll of these devices are fully programmable via the sophisticated CF2000 multi stage cause and effect programming facilities

All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

CBG370

CBG370S

CBG370WP

Analogue

15

Base sounder

The CAS380 has been designed specifically to complement the latest generation of Cooper Fire Systems soft addressed detectorsit consists of a first fix bracket and a main body which clips onto the bracket incorporating the sounder and a detector mounting base in a single composite assembly

After the body has been clicked into place and connected a sensor or front cover is then added to complete a very simple quick and neat installationThe cover enables the CAS380 to be used as a discreet stand alone wall or ceiling mounted deviceThe sounder base design incorporates a mechanism that can be activated if required to lock either the sensor or the cover into place to prevent unauthorised removal

Dedicated Stand alone sounders

Stand alone sounders are ideal for applications where greater sound outputs are required than can be achieved with a base sounder or for applications requiring a higher level of resilience or ingress protectionTwo different versions are available standard version and an IP66 rated version

CAS380

CAS381 CAS381WP

CAS380 with sensor fitted CAS380 with CASC fitted

Compatible Equipment

16

Interfaces

CF2000 has been designed to be suitable for a wide range of applications various interfaces have been developed to enable the simple integration of other fire systems or building control and safety systems The following devices are available

3 Channel IO device (CIO351)

CIO351 has 3 input channels and 3 output channels it is used to monitor up to three separate inputs from equipment such as sprinkler flow switches and also to provide 3 separately controlled volt free output contacts which are intended to be used to control external equipment such as air handling plant or access control systemsAll inputs and outputs operate completely independently of each other and can be programmed using the sophisticated cause and effect capabilities of CF2000 to operate either globally or in response to activation of specific devices or specific inputsInputs are monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalInputs are suitable for use as fire signal inputs such as from a sprinkler flow switch however they can also be used to monitor non fire inputs such as external keyswitchesOutputs are rated to switch a maximum of 1A resistive at 30V DCThe CIO351 is supplied in a surface mounting IP65 box

1 Channel IO device with mains rated switching capability (CMIO353)

CMIO353 is a single channel input output unit the output is capable of switching up to 1A at 230V ACCommonly used for applications such as door release controls and plant shut down signaling

The input is monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalThe input is suitable for use as a fire signal input such as from a sprinkler flow switch however it can also be used to monitor non fire inputs such as an external keyswitchThe CIO353 is supplied in a surface mounting IP65 box

CIO351 CMIO353

17

Zone monitor unit (CZMU352)

CZMU352 is designed to enable a zone of compatible conventional detectors and callpoints to be connected into the CF2000 loop it is compatible with up to 20 Cooper Fire Systems conventional detectors connected via CDBB300 basesPlease refer to local standards egBS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone CZMU352 fixes to a standard deep double gang back box and can be either surface or semi recess mounted When semi recessed only the front section protrudes giving a maximum 29mm depth

Shop unit Interface (CSUM355)

CSUM355 accepts a zone of conventional detectors plus an unlimited number of callpoints which can be connected to the same input as the detectors or a separate callpoint input if requiredIt also has a 24V 1A rated relay output and a facility to connect a power supply which can then be monitored for faultIn addition it has the facility to connect two circuits of conventional polarised sounders which are monitored by means of an end of line resistor and powered in alarm conditions from the external power supplyThe sounder circuits can be programmed to operate in pulsed continuous or time delayed mode

Please refer to local standards eg BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone The CSUM355 is supplied in a surface mounting IP65 box

Interfaces

CSUM355

CZUM352

18

(CZMU352)

Spur Isolator (CSI350)

CSI350 enables soft addressing to work when the loop contains spurs it controls the addressing operation so that when the system reaches a spur all devices on the spur are allocated an address before it continues addressing the loopThe device also incorporates a short circuit isolatorBecause each device contains a short circuit isolator only 1 is required at the start of each spur

CSI350 is mounted on a standard deep double gang back box (supplied)

Please refer to BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone

4 Way sounder circuit controller (CS354)

CSC354 provides power for 4 separately controllable conventional sounder circuits each circuit can be separately programmedCSC354 is designed to greatly simplify installation in applications where specialist sounders or beacons are required since it powers the sounders and allows full control of the sounder operation without having to wire the sounder back to the CF2000 control panel

A 4 way unit takes up a single address but each circuit can be independently controlledAn CSC354 unit requires a local un-switched 230V supply and incorporates a back up battery to 24 hours of standby operation followed by a minimum of 30 minutes of full alarm ringingA standby of 72 hours can be achieved at the expense of reduced load capability

Interfaces

CSI350

CSC354

19

Equipment Compatibility

SensorsLoop wired sensors must be of the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional detectors can be connected via an CZMU352 interface The connection of other detector types via an CZMU352 interface is not recommended

Call pointsLoop wired call points must be the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional callpoints can be connected via an CZMU352 interface The connection of other callpoint types via an CZMU352 interface is not recommended

SoundersLoop powered addressable sounders must be of the Cooper Fire Systems 300 series soft addressed analogue type

Conventional sounders can also be connected either to the conventional sounder circuits at the panel or to the loop via a CSC354 addressable sounder controller interface providing they meet the following1) They are suitable for operation between 18V and 28V2) They are polarised and suppressed3) The total alarm load is less than the rating of the panel Alarm Power Interface

Note It is possible to use devices outside these requirements if they are supplied with power from a separate source and switched via a suitable relay

Relay circuitsAdditional relays can be added to the CF2000 system by using either CMIO353 or CIO351 relay units

Relays Auto-dialers and auxiliary equipmentA wide variety of relays and other equipment can be connected to the CF2000 system but you should note the following constraints

1) CF2000 provides monitored outputs to drive fire and fault relays mounted in external equipment External relays should be suppressed If a non-suppressed relay is used then a diode can be connected to suppress any reverse EMF on the release of the relay which might cause the panel to malfunction

2) A 24V DC output is provided at the panel to make it easy to connect ancillary equipment Although the panel can supply a continuous quiescent load of up to 30mA BS5839 precludes this practice and any ancillary equipment you connect should only consume power in the alarm or fault mode to meet the requirements of BS5839

20

System Overview

Simple user interface

The main element of the user interface with CF2000 is a (60mm x 30mm visible area) display which provides comprehensive user information

As well as an LCD display providing full system status information the panel incorporates 32 traditional zone indication LEDs to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the systemIn addition there are a number of system status LEDs designed to give clear status information to non technical users

User configuration and maintenance facilities

CF2000 has comprehensive facilities for on site system configuration whereby the user can add or remove simple devices without the need for a service engineer to visit site For initial configuration or major system changes special PC configuration software is available enabling Cooper Fire Systems personnel to do this more efficiently than can be achieved using the system screen Exiting configurations can be uploaded to the PC so that changes can be made to the existing system rather than having to revert to initial filesDuring the yearly maintenance all terminal under main supply shall be verified

21

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 15: CF2000 User Manual

Compatible Equipment

Compatible callpoints

The range of purpose designed callpoints for the CF2000 consists of a surface callpoint a flush callpoint and a surface weatherproof callpointA range of accessories is available including a hinged protective cover Resettable element kit and a flush bezelThe status LED can be programmed to either be permanently off under normal conditions or to pulse in order to confirm that it is in communication with the CF2000 control panel

Compatible Sounders and Beacons

A wide range of loop powered sounders and beacons are available to operate with the CF2000 consisting of a combined sounder base with a maximum output of 95 dB(A) a standalone sounder with a maximum output of 100 dB(A) that is available in standard or weatherproof versions and a stand alone loop powered beaconFor applications where a discreet dedicated sounder is required a cover plate is available for the white base mounted sounder enabling it to be used as a stand alone wall or ceiling mounted sounderAll of these devices are fully programmable via the sophisticated CF2000 multi stage cause and effect programming facilities

All sounders have multiple selectable volume settings the volume setting is controlled by the CF2000 panel and so can be altered without needing to access the sounder

CBG370

CBG370S

CBG370WP

Analogue

15

Base sounder

The CAS380 has been designed specifically to complement the latest generation of Cooper Fire Systems soft addressed detectorsit consists of a first fix bracket and a main body which clips onto the bracket incorporating the sounder and a detector mounting base in a single composite assembly

After the body has been clicked into place and connected a sensor or front cover is then added to complete a very simple quick and neat installationThe cover enables the CAS380 to be used as a discreet stand alone wall or ceiling mounted deviceThe sounder base design incorporates a mechanism that can be activated if required to lock either the sensor or the cover into place to prevent unauthorised removal

Dedicated Stand alone sounders

Stand alone sounders are ideal for applications where greater sound outputs are required than can be achieved with a base sounder or for applications requiring a higher level of resilience or ingress protectionTwo different versions are available standard version and an IP66 rated version

CAS380

CAS381 CAS381WP

CAS380 with sensor fitted CAS380 with CASC fitted

Compatible Equipment

16

Interfaces

CF2000 has been designed to be suitable for a wide range of applications various interfaces have been developed to enable the simple integration of other fire systems or building control and safety systems The following devices are available

3 Channel IO device (CIO351)

CIO351 has 3 input channels and 3 output channels it is used to monitor up to three separate inputs from equipment such as sprinkler flow switches and also to provide 3 separately controlled volt free output contacts which are intended to be used to control external equipment such as air handling plant or access control systemsAll inputs and outputs operate completely independently of each other and can be programmed using the sophisticated cause and effect capabilities of CF2000 to operate either globally or in response to activation of specific devices or specific inputsInputs are monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalInputs are suitable for use as fire signal inputs such as from a sprinkler flow switch however they can also be used to monitor non fire inputs such as external keyswitchesOutputs are rated to switch a maximum of 1A resistive at 30V DCThe CIO351 is supplied in a surface mounting IP65 box

1 Channel IO device with mains rated switching capability (CMIO353)

CMIO353 is a single channel input output unit the output is capable of switching up to 1A at 230V ACCommonly used for applications such as door release controls and plant shut down signaling

The input is monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalThe input is suitable for use as a fire signal input such as from a sprinkler flow switch however it can also be used to monitor non fire inputs such as an external keyswitchThe CIO353 is supplied in a surface mounting IP65 box

CIO351 CMIO353

17

Zone monitor unit (CZMU352)

CZMU352 is designed to enable a zone of compatible conventional detectors and callpoints to be connected into the CF2000 loop it is compatible with up to 20 Cooper Fire Systems conventional detectors connected via CDBB300 basesPlease refer to local standards egBS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone CZMU352 fixes to a standard deep double gang back box and can be either surface or semi recess mounted When semi recessed only the front section protrudes giving a maximum 29mm depth

Shop unit Interface (CSUM355)

CSUM355 accepts a zone of conventional detectors plus an unlimited number of callpoints which can be connected to the same input as the detectors or a separate callpoint input if requiredIt also has a 24V 1A rated relay output and a facility to connect a power supply which can then be monitored for faultIn addition it has the facility to connect two circuits of conventional polarised sounders which are monitored by means of an end of line resistor and powered in alarm conditions from the external power supplyThe sounder circuits can be programmed to operate in pulsed continuous or time delayed mode

Please refer to local standards eg BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone The CSUM355 is supplied in a surface mounting IP65 box

Interfaces

CSUM355

CZUM352

18

(CZMU352)

Spur Isolator (CSI350)

CSI350 enables soft addressing to work when the loop contains spurs it controls the addressing operation so that when the system reaches a spur all devices on the spur are allocated an address before it continues addressing the loopThe device also incorporates a short circuit isolatorBecause each device contains a short circuit isolator only 1 is required at the start of each spur

CSI350 is mounted on a standard deep double gang back box (supplied)

Please refer to BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone

4 Way sounder circuit controller (CS354)

CSC354 provides power for 4 separately controllable conventional sounder circuits each circuit can be separately programmedCSC354 is designed to greatly simplify installation in applications where specialist sounders or beacons are required since it powers the sounders and allows full control of the sounder operation without having to wire the sounder back to the CF2000 control panel

A 4 way unit takes up a single address but each circuit can be independently controlledAn CSC354 unit requires a local un-switched 230V supply and incorporates a back up battery to 24 hours of standby operation followed by a minimum of 30 minutes of full alarm ringingA standby of 72 hours can be achieved at the expense of reduced load capability

Interfaces

CSI350

CSC354

19

Equipment Compatibility

SensorsLoop wired sensors must be of the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional detectors can be connected via an CZMU352 interface The connection of other detector types via an CZMU352 interface is not recommended

Call pointsLoop wired call points must be the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional callpoints can be connected via an CZMU352 interface The connection of other callpoint types via an CZMU352 interface is not recommended

SoundersLoop powered addressable sounders must be of the Cooper Fire Systems 300 series soft addressed analogue type

Conventional sounders can also be connected either to the conventional sounder circuits at the panel or to the loop via a CSC354 addressable sounder controller interface providing they meet the following1) They are suitable for operation between 18V and 28V2) They are polarised and suppressed3) The total alarm load is less than the rating of the panel Alarm Power Interface

Note It is possible to use devices outside these requirements if they are supplied with power from a separate source and switched via a suitable relay

Relay circuitsAdditional relays can be added to the CF2000 system by using either CMIO353 or CIO351 relay units

Relays Auto-dialers and auxiliary equipmentA wide variety of relays and other equipment can be connected to the CF2000 system but you should note the following constraints

1) CF2000 provides monitored outputs to drive fire and fault relays mounted in external equipment External relays should be suppressed If a non-suppressed relay is used then a diode can be connected to suppress any reverse EMF on the release of the relay which might cause the panel to malfunction

2) A 24V DC output is provided at the panel to make it easy to connect ancillary equipment Although the panel can supply a continuous quiescent load of up to 30mA BS5839 precludes this practice and any ancillary equipment you connect should only consume power in the alarm or fault mode to meet the requirements of BS5839

20

System Overview

Simple user interface

The main element of the user interface with CF2000 is a (60mm x 30mm visible area) display which provides comprehensive user information

As well as an LCD display providing full system status information the panel incorporates 32 traditional zone indication LEDs to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the systemIn addition there are a number of system status LEDs designed to give clear status information to non technical users

User configuration and maintenance facilities

CF2000 has comprehensive facilities for on site system configuration whereby the user can add or remove simple devices without the need for a service engineer to visit site For initial configuration or major system changes special PC configuration software is available enabling Cooper Fire Systems personnel to do this more efficiently than can be achieved using the system screen Exiting configurations can be uploaded to the PC so that changes can be made to the existing system rather than having to revert to initial filesDuring the yearly maintenance all terminal under main supply shall be verified

21

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 16: CF2000 User Manual

Base sounder

The CAS380 has been designed specifically to complement the latest generation of Cooper Fire Systems soft addressed detectorsit consists of a first fix bracket and a main body which clips onto the bracket incorporating the sounder and a detector mounting base in a single composite assembly

After the body has been clicked into place and connected a sensor or front cover is then added to complete a very simple quick and neat installationThe cover enables the CAS380 to be used as a discreet stand alone wall or ceiling mounted deviceThe sounder base design incorporates a mechanism that can be activated if required to lock either the sensor or the cover into place to prevent unauthorised removal

Dedicated Stand alone sounders

Stand alone sounders are ideal for applications where greater sound outputs are required than can be achieved with a base sounder or for applications requiring a higher level of resilience or ingress protectionTwo different versions are available standard version and an IP66 rated version

CAS380

CAS381 CAS381WP

CAS380 with sensor fitted CAS380 with CASC fitted

Compatible Equipment

16

Interfaces

CF2000 has been designed to be suitable for a wide range of applications various interfaces have been developed to enable the simple integration of other fire systems or building control and safety systems The following devices are available

3 Channel IO device (CIO351)

CIO351 has 3 input channels and 3 output channels it is used to monitor up to three separate inputs from equipment such as sprinkler flow switches and also to provide 3 separately controlled volt free output contacts which are intended to be used to control external equipment such as air handling plant or access control systemsAll inputs and outputs operate completely independently of each other and can be programmed using the sophisticated cause and effect capabilities of CF2000 to operate either globally or in response to activation of specific devices or specific inputsInputs are monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalInputs are suitable for use as fire signal inputs such as from a sprinkler flow switch however they can also be used to monitor non fire inputs such as external keyswitchesOutputs are rated to switch a maximum of 1A resistive at 30V DCThe CIO351 is supplied in a surface mounting IP65 box

1 Channel IO device with mains rated switching capability (CMIO353)

CMIO353 is a single channel input output unit the output is capable of switching up to 1A at 230V ACCommonly used for applications such as door release controls and plant shut down signaling

The input is monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalThe input is suitable for use as a fire signal input such as from a sprinkler flow switch however it can also be used to monitor non fire inputs such as an external keyswitchThe CIO353 is supplied in a surface mounting IP65 box

CIO351 CMIO353

17

Zone monitor unit (CZMU352)

CZMU352 is designed to enable a zone of compatible conventional detectors and callpoints to be connected into the CF2000 loop it is compatible with up to 20 Cooper Fire Systems conventional detectors connected via CDBB300 basesPlease refer to local standards egBS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone CZMU352 fixes to a standard deep double gang back box and can be either surface or semi recess mounted When semi recessed only the front section protrudes giving a maximum 29mm depth

Shop unit Interface (CSUM355)

CSUM355 accepts a zone of conventional detectors plus an unlimited number of callpoints which can be connected to the same input as the detectors or a separate callpoint input if requiredIt also has a 24V 1A rated relay output and a facility to connect a power supply which can then be monitored for faultIn addition it has the facility to connect two circuits of conventional polarised sounders which are monitored by means of an end of line resistor and powered in alarm conditions from the external power supplyThe sounder circuits can be programmed to operate in pulsed continuous or time delayed mode

Please refer to local standards eg BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone The CSUM355 is supplied in a surface mounting IP65 box

Interfaces

CSUM355

CZUM352

18

(CZMU352)

Spur Isolator (CSI350)

CSI350 enables soft addressing to work when the loop contains spurs it controls the addressing operation so that when the system reaches a spur all devices on the spur are allocated an address before it continues addressing the loopThe device also incorporates a short circuit isolatorBecause each device contains a short circuit isolator only 1 is required at the start of each spur

CSI350 is mounted on a standard deep double gang back box (supplied)

Please refer to BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone

4 Way sounder circuit controller (CS354)

CSC354 provides power for 4 separately controllable conventional sounder circuits each circuit can be separately programmedCSC354 is designed to greatly simplify installation in applications where specialist sounders or beacons are required since it powers the sounders and allows full control of the sounder operation without having to wire the sounder back to the CF2000 control panel

A 4 way unit takes up a single address but each circuit can be independently controlledAn CSC354 unit requires a local un-switched 230V supply and incorporates a back up battery to 24 hours of standby operation followed by a minimum of 30 minutes of full alarm ringingA standby of 72 hours can be achieved at the expense of reduced load capability

Interfaces

CSI350

CSC354

19

Equipment Compatibility

SensorsLoop wired sensors must be of the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional detectors can be connected via an CZMU352 interface The connection of other detector types via an CZMU352 interface is not recommended

Call pointsLoop wired call points must be the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional callpoints can be connected via an CZMU352 interface The connection of other callpoint types via an CZMU352 interface is not recommended

SoundersLoop powered addressable sounders must be of the Cooper Fire Systems 300 series soft addressed analogue type

Conventional sounders can also be connected either to the conventional sounder circuits at the panel or to the loop via a CSC354 addressable sounder controller interface providing they meet the following1) They are suitable for operation between 18V and 28V2) They are polarised and suppressed3) The total alarm load is less than the rating of the panel Alarm Power Interface

Note It is possible to use devices outside these requirements if they are supplied with power from a separate source and switched via a suitable relay

Relay circuitsAdditional relays can be added to the CF2000 system by using either CMIO353 or CIO351 relay units

Relays Auto-dialers and auxiliary equipmentA wide variety of relays and other equipment can be connected to the CF2000 system but you should note the following constraints

1) CF2000 provides monitored outputs to drive fire and fault relays mounted in external equipment External relays should be suppressed If a non-suppressed relay is used then a diode can be connected to suppress any reverse EMF on the release of the relay which might cause the panel to malfunction

2) A 24V DC output is provided at the panel to make it easy to connect ancillary equipment Although the panel can supply a continuous quiescent load of up to 30mA BS5839 precludes this practice and any ancillary equipment you connect should only consume power in the alarm or fault mode to meet the requirements of BS5839

20

System Overview

Simple user interface

The main element of the user interface with CF2000 is a (60mm x 30mm visible area) display which provides comprehensive user information

As well as an LCD display providing full system status information the panel incorporates 32 traditional zone indication LEDs to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the systemIn addition there are a number of system status LEDs designed to give clear status information to non technical users

User configuration and maintenance facilities

CF2000 has comprehensive facilities for on site system configuration whereby the user can add or remove simple devices without the need for a service engineer to visit site For initial configuration or major system changes special PC configuration software is available enabling Cooper Fire Systems personnel to do this more efficiently than can be achieved using the system screen Exiting configurations can be uploaded to the PC so that changes can be made to the existing system rather than having to revert to initial filesDuring the yearly maintenance all terminal under main supply shall be verified

21

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 17: CF2000 User Manual

Interfaces

CF2000 has been designed to be suitable for a wide range of applications various interfaces have been developed to enable the simple integration of other fire systems or building control and safety systems The following devices are available

3 Channel IO device (CIO351)

CIO351 has 3 input channels and 3 output channels it is used to monitor up to three separate inputs from equipment such as sprinkler flow switches and also to provide 3 separately controlled volt free output contacts which are intended to be used to control external equipment such as air handling plant or access control systemsAll inputs and outputs operate completely independently of each other and can be programmed using the sophisticated cause and effect capabilities of CF2000 to operate either globally or in response to activation of specific devices or specific inputsInputs are monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalInputs are suitable for use as fire signal inputs such as from a sprinkler flow switch however they can also be used to monitor non fire inputs such as external keyswitchesOutputs are rated to switch a maximum of 1A resistive at 30V DCThe CIO351 is supplied in a surface mounting IP65 box

1 Channel IO device with mains rated switching capability (CMIO353)

CMIO353 is a single channel input output unit the output is capable of switching up to 1A at 230V ACCommonly used for applications such as door release controls and plant shut down signaling

The input is monitored for open and short circuits a specific resistance is required to activate an alarm condition fully open or short circuit conditions are monitored and generate a system fault signalThe input is suitable for use as a fire signal input such as from a sprinkler flow switch however it can also be used to monitor non fire inputs such as an external keyswitchThe CIO353 is supplied in a surface mounting IP65 box

CIO351 CMIO353

17

Zone monitor unit (CZMU352)

CZMU352 is designed to enable a zone of compatible conventional detectors and callpoints to be connected into the CF2000 loop it is compatible with up to 20 Cooper Fire Systems conventional detectors connected via CDBB300 basesPlease refer to local standards egBS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone CZMU352 fixes to a standard deep double gang back box and can be either surface or semi recess mounted When semi recessed only the front section protrudes giving a maximum 29mm depth

Shop unit Interface (CSUM355)

CSUM355 accepts a zone of conventional detectors plus an unlimited number of callpoints which can be connected to the same input as the detectors or a separate callpoint input if requiredIt also has a 24V 1A rated relay output and a facility to connect a power supply which can then be monitored for faultIn addition it has the facility to connect two circuits of conventional polarised sounders which are monitored by means of an end of line resistor and powered in alarm conditions from the external power supplyThe sounder circuits can be programmed to operate in pulsed continuous or time delayed mode

Please refer to local standards eg BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone The CSUM355 is supplied in a surface mounting IP65 box

Interfaces

CSUM355

CZUM352

18

(CZMU352)

Spur Isolator (CSI350)

CSI350 enables soft addressing to work when the loop contains spurs it controls the addressing operation so that when the system reaches a spur all devices on the spur are allocated an address before it continues addressing the loopThe device also incorporates a short circuit isolatorBecause each device contains a short circuit isolator only 1 is required at the start of each spur

CSI350 is mounted on a standard deep double gang back box (supplied)

Please refer to BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone

4 Way sounder circuit controller (CS354)

CSC354 provides power for 4 separately controllable conventional sounder circuits each circuit can be separately programmedCSC354 is designed to greatly simplify installation in applications where specialist sounders or beacons are required since it powers the sounders and allows full control of the sounder operation without having to wire the sounder back to the CF2000 control panel

A 4 way unit takes up a single address but each circuit can be independently controlledAn CSC354 unit requires a local un-switched 230V supply and incorporates a back up battery to 24 hours of standby operation followed by a minimum of 30 minutes of full alarm ringingA standby of 72 hours can be achieved at the expense of reduced load capability

Interfaces

CSI350

CSC354

19

Equipment Compatibility

SensorsLoop wired sensors must be of the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional detectors can be connected via an CZMU352 interface The connection of other detector types via an CZMU352 interface is not recommended

Call pointsLoop wired call points must be the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional callpoints can be connected via an CZMU352 interface The connection of other callpoint types via an CZMU352 interface is not recommended

SoundersLoop powered addressable sounders must be of the Cooper Fire Systems 300 series soft addressed analogue type

Conventional sounders can also be connected either to the conventional sounder circuits at the panel or to the loop via a CSC354 addressable sounder controller interface providing they meet the following1) They are suitable for operation between 18V and 28V2) They are polarised and suppressed3) The total alarm load is less than the rating of the panel Alarm Power Interface

Note It is possible to use devices outside these requirements if they are supplied with power from a separate source and switched via a suitable relay

Relay circuitsAdditional relays can be added to the CF2000 system by using either CMIO353 or CIO351 relay units

Relays Auto-dialers and auxiliary equipmentA wide variety of relays and other equipment can be connected to the CF2000 system but you should note the following constraints

1) CF2000 provides monitored outputs to drive fire and fault relays mounted in external equipment External relays should be suppressed If a non-suppressed relay is used then a diode can be connected to suppress any reverse EMF on the release of the relay which might cause the panel to malfunction

2) A 24V DC output is provided at the panel to make it easy to connect ancillary equipment Although the panel can supply a continuous quiescent load of up to 30mA BS5839 precludes this practice and any ancillary equipment you connect should only consume power in the alarm or fault mode to meet the requirements of BS5839

20

System Overview

Simple user interface

The main element of the user interface with CF2000 is a (60mm x 30mm visible area) display which provides comprehensive user information

As well as an LCD display providing full system status information the panel incorporates 32 traditional zone indication LEDs to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the systemIn addition there are a number of system status LEDs designed to give clear status information to non technical users

User configuration and maintenance facilities

CF2000 has comprehensive facilities for on site system configuration whereby the user can add or remove simple devices without the need for a service engineer to visit site For initial configuration or major system changes special PC configuration software is available enabling Cooper Fire Systems personnel to do this more efficiently than can be achieved using the system screen Exiting configurations can be uploaded to the PC so that changes can be made to the existing system rather than having to revert to initial filesDuring the yearly maintenance all terminal under main supply shall be verified

21

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 18: CF2000 User Manual

Zone monitor unit (CZMU352)

CZMU352 is designed to enable a zone of compatible conventional detectors and callpoints to be connected into the CF2000 loop it is compatible with up to 20 Cooper Fire Systems conventional detectors connected via CDBB300 basesPlease refer to local standards egBS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone CZMU352 fixes to a standard deep double gang back box and can be either surface or semi recess mounted When semi recessed only the front section protrudes giving a maximum 29mm depth

Shop unit Interface (CSUM355)

CSUM355 accepts a zone of conventional detectors plus an unlimited number of callpoints which can be connected to the same input as the detectors or a separate callpoint input if requiredIt also has a 24V 1A rated relay output and a facility to connect a power supply which can then be monitored for faultIn addition it has the facility to connect two circuits of conventional polarised sounders which are monitored by means of an end of line resistor and powered in alarm conditions from the external power supplyThe sounder circuits can be programmed to operate in pulsed continuous or time delayed mode

Please refer to local standards eg BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone The CSUM355 is supplied in a surface mounting IP65 box

Interfaces

CSUM355

CZUM352

18

(CZMU352)

Spur Isolator (CSI350)

CSI350 enables soft addressing to work when the loop contains spurs it controls the addressing operation so that when the system reaches a spur all devices on the spur are allocated an address before it continues addressing the loopThe device also incorporates a short circuit isolatorBecause each device contains a short circuit isolator only 1 is required at the start of each spur

CSI350 is mounted on a standard deep double gang back box (supplied)

Please refer to BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone

4 Way sounder circuit controller (CS354)

CSC354 provides power for 4 separately controllable conventional sounder circuits each circuit can be separately programmedCSC354 is designed to greatly simplify installation in applications where specialist sounders or beacons are required since it powers the sounders and allows full control of the sounder operation without having to wire the sounder back to the CF2000 control panel

A 4 way unit takes up a single address but each circuit can be independently controlledAn CSC354 unit requires a local un-switched 230V supply and incorporates a back up battery to 24 hours of standby operation followed by a minimum of 30 minutes of full alarm ringingA standby of 72 hours can be achieved at the expense of reduced load capability

Interfaces

CSI350

CSC354

19

Equipment Compatibility

SensorsLoop wired sensors must be of the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional detectors can be connected via an CZMU352 interface The connection of other detector types via an CZMU352 interface is not recommended

Call pointsLoop wired call points must be the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional callpoints can be connected via an CZMU352 interface The connection of other callpoint types via an CZMU352 interface is not recommended

SoundersLoop powered addressable sounders must be of the Cooper Fire Systems 300 series soft addressed analogue type

Conventional sounders can also be connected either to the conventional sounder circuits at the panel or to the loop via a CSC354 addressable sounder controller interface providing they meet the following1) They are suitable for operation between 18V and 28V2) They are polarised and suppressed3) The total alarm load is less than the rating of the panel Alarm Power Interface

Note It is possible to use devices outside these requirements if they are supplied with power from a separate source and switched via a suitable relay

Relay circuitsAdditional relays can be added to the CF2000 system by using either CMIO353 or CIO351 relay units

Relays Auto-dialers and auxiliary equipmentA wide variety of relays and other equipment can be connected to the CF2000 system but you should note the following constraints

1) CF2000 provides monitored outputs to drive fire and fault relays mounted in external equipment External relays should be suppressed If a non-suppressed relay is used then a diode can be connected to suppress any reverse EMF on the release of the relay which might cause the panel to malfunction

2) A 24V DC output is provided at the panel to make it easy to connect ancillary equipment Although the panel can supply a continuous quiescent load of up to 30mA BS5839 precludes this practice and any ancillary equipment you connect should only consume power in the alarm or fault mode to meet the requirements of BS5839

20

System Overview

Simple user interface

The main element of the user interface with CF2000 is a (60mm x 30mm visible area) display which provides comprehensive user information

As well as an LCD display providing full system status information the panel incorporates 32 traditional zone indication LEDs to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the systemIn addition there are a number of system status LEDs designed to give clear status information to non technical users

User configuration and maintenance facilities

CF2000 has comprehensive facilities for on site system configuration whereby the user can add or remove simple devices without the need for a service engineer to visit site For initial configuration or major system changes special PC configuration software is available enabling Cooper Fire Systems personnel to do this more efficiently than can be achieved using the system screen Exiting configurations can be uploaded to the PC so that changes can be made to the existing system rather than having to revert to initial filesDuring the yearly maintenance all terminal under main supply shall be verified

21

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 19: CF2000 User Manual

Spur Isolator (CSI350)

CSI350 enables soft addressing to work when the loop contains spurs it controls the addressing operation so that when the system reaches a spur all devices on the spur are allocated an address before it continues addressing the loopThe device also incorporates a short circuit isolatorBecause each device contains a short circuit isolator only 1 is required at the start of each spur

CSI350 is mounted on a standard deep double gang back box (supplied)

Please refer to BS5839 Pt12002 for details of the maximum allowable area to be covered by a single spur zone

4 Way sounder circuit controller (CS354)

CSC354 provides power for 4 separately controllable conventional sounder circuits each circuit can be separately programmedCSC354 is designed to greatly simplify installation in applications where specialist sounders or beacons are required since it powers the sounders and allows full control of the sounder operation without having to wire the sounder back to the CF2000 control panel

A 4 way unit takes up a single address but each circuit can be independently controlledAn CSC354 unit requires a local un-switched 230V supply and incorporates a back up battery to 24 hours of standby operation followed by a minimum of 30 minutes of full alarm ringingA standby of 72 hours can be achieved at the expense of reduced load capability

Interfaces

CSI350

CSC354

19

Equipment Compatibility

SensorsLoop wired sensors must be of the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional detectors can be connected via an CZMU352 interface The connection of other detector types via an CZMU352 interface is not recommended

Call pointsLoop wired call points must be the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional callpoints can be connected via an CZMU352 interface The connection of other callpoint types via an CZMU352 interface is not recommended

SoundersLoop powered addressable sounders must be of the Cooper Fire Systems 300 series soft addressed analogue type

Conventional sounders can also be connected either to the conventional sounder circuits at the panel or to the loop via a CSC354 addressable sounder controller interface providing they meet the following1) They are suitable for operation between 18V and 28V2) They are polarised and suppressed3) The total alarm load is less than the rating of the panel Alarm Power Interface

Note It is possible to use devices outside these requirements if they are supplied with power from a separate source and switched via a suitable relay

Relay circuitsAdditional relays can be added to the CF2000 system by using either CMIO353 or CIO351 relay units

Relays Auto-dialers and auxiliary equipmentA wide variety of relays and other equipment can be connected to the CF2000 system but you should note the following constraints

1) CF2000 provides monitored outputs to drive fire and fault relays mounted in external equipment External relays should be suppressed If a non-suppressed relay is used then a diode can be connected to suppress any reverse EMF on the release of the relay which might cause the panel to malfunction

2) A 24V DC output is provided at the panel to make it easy to connect ancillary equipment Although the panel can supply a continuous quiescent load of up to 30mA BS5839 precludes this practice and any ancillary equipment you connect should only consume power in the alarm or fault mode to meet the requirements of BS5839

20

System Overview

Simple user interface

The main element of the user interface with CF2000 is a (60mm x 30mm visible area) display which provides comprehensive user information

As well as an LCD display providing full system status information the panel incorporates 32 traditional zone indication LEDs to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the systemIn addition there are a number of system status LEDs designed to give clear status information to non technical users

User configuration and maintenance facilities

CF2000 has comprehensive facilities for on site system configuration whereby the user can add or remove simple devices without the need for a service engineer to visit site For initial configuration or major system changes special PC configuration software is available enabling Cooper Fire Systems personnel to do this more efficiently than can be achieved using the system screen Exiting configurations can be uploaded to the PC so that changes can be made to the existing system rather than having to revert to initial filesDuring the yearly maintenance all terminal under main supply shall be verified

21

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 20: CF2000 User Manual

Equipment Compatibility

SensorsLoop wired sensors must be of the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional detectors can be connected via an CZMU352 interface The connection of other detector types via an CZMU352 interface is not recommended

Call pointsLoop wired call points must be the Cooper Fire Systems 300 series soft addressed analogue type Cooper Fire Systems 300 series conventional callpoints can be connected via an CZMU352 interface The connection of other callpoint types via an CZMU352 interface is not recommended

SoundersLoop powered addressable sounders must be of the Cooper Fire Systems 300 series soft addressed analogue type

Conventional sounders can also be connected either to the conventional sounder circuits at the panel or to the loop via a CSC354 addressable sounder controller interface providing they meet the following1) They are suitable for operation between 18V and 28V2) They are polarised and suppressed3) The total alarm load is less than the rating of the panel Alarm Power Interface

Note It is possible to use devices outside these requirements if they are supplied with power from a separate source and switched via a suitable relay

Relay circuitsAdditional relays can be added to the CF2000 system by using either CMIO353 or CIO351 relay units

Relays Auto-dialers and auxiliary equipmentA wide variety of relays and other equipment can be connected to the CF2000 system but you should note the following constraints

1) CF2000 provides monitored outputs to drive fire and fault relays mounted in external equipment External relays should be suppressed If a non-suppressed relay is used then a diode can be connected to suppress any reverse EMF on the release of the relay which might cause the panel to malfunction

2) A 24V DC output is provided at the panel to make it easy to connect ancillary equipment Although the panel can supply a continuous quiescent load of up to 30mA BS5839 precludes this practice and any ancillary equipment you connect should only consume power in the alarm or fault mode to meet the requirements of BS5839

20

System Overview

Simple user interface

The main element of the user interface with CF2000 is a (60mm x 30mm visible area) display which provides comprehensive user information

As well as an LCD display providing full system status information the panel incorporates 32 traditional zone indication LEDs to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the systemIn addition there are a number of system status LEDs designed to give clear status information to non technical users

User configuration and maintenance facilities

CF2000 has comprehensive facilities for on site system configuration whereby the user can add or remove simple devices without the need for a service engineer to visit site For initial configuration or major system changes special PC configuration software is available enabling Cooper Fire Systems personnel to do this more efficiently than can be achieved using the system screen Exiting configurations can be uploaded to the PC so that changes can be made to the existing system rather than having to revert to initial filesDuring the yearly maintenance all terminal under main supply shall be verified

21

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 21: CF2000 User Manual

System Overview

Simple user interface

The main element of the user interface with CF2000 is a (60mm x 30mm visible area) display which provides comprehensive user information

As well as an LCD display providing full system status information the panel incorporates 32 traditional zone indication LEDs to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the systemIn addition there are a number of system status LEDs designed to give clear status information to non technical users

User configuration and maintenance facilities

CF2000 has comprehensive facilities for on site system configuration whereby the user can add or remove simple devices without the need for a service engineer to visit site For initial configuration or major system changes special PC configuration software is available enabling Cooper Fire Systems personnel to do this more efficiently than can be achieved using the system screen Exiting configurations can be uploaded to the PC so that changes can be made to the existing system rather than having to revert to initial filesDuring the yearly maintenance all terminal under main supply shall be verified

21

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 22: CF2000 User Manual

System Overview

Spur tolerant soft addressing

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processesOnce the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

A major innovation with CF2000 is the ability to incorporate spurs of analogue devices which are fed from the main loop by utilising a spur isolatorWhenever the panel detects a spur it breaks from allocating address numbers to the loop wired devices allocates address numbers to each of the devices on the spur in sequence and then continues to address the devices on the main loop

Every CF2000 analogue device incorporates an integral short circuit isolator ensuring maximum system integrity A single short circuit will not disable any loop-mounted devices the isolators in the devices each side of the short circuit will operate and the CF2000 control panel will drive communication from both ends of the loopThe spur isolator also incorporates a short circuit isolator such that in the event of a short circuit on the spur the integrity of the main loop will not be compromised Please refer to local standards local standard for details of the maximum allowable are to be covered by a single spur

Integral Power Supply and Battery

The CF2000 panel is designed for ease of installation the power supply and battery are integral to the main control panel so only a single panel is required

22

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 23: CF2000 User Manual

Optional printer

System Overview

23

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 24: CF2000 User Manual

Technical Specification

Power Supply (Approved EN54 pt 4)MainsNominal Voltage 230 Vac + 10 -15Nominal Current 40mAMaximum Current 500mAInput Fuse R1 Anti Surge 16AmpOutput Voltage including tolerances 26V = 185 to 295Volts

26V RAW = 185 to 295Volts 5Volt Output = 46V to 55V

Ripple Voltages 26V = 800mV 26V RAW = 800mV 5Volt Output = 430mV

Maximum Loadings 26V OP = 048A 26V RAW OP = 12A 5V = 05A

Standby Current (4 Loops Loaded) 26V = 140mA 26V RAW = 50mA 26V = 140mA 26V RAW = 50mA 5V = 30mA

I max a I max b amp I min = Current as specified in BSEN54-4 Published 2006 (Amendments 1 amp 2)

BatteriesNumber of Batteries 2Manufacturer YUASA NP7-12Capacity 7 AhBattery Fuse 63A Anti-Surge (F4)Maximum battery current 30 AmpsStandby current (mA) 125 (2 loops)Maximum Charging Current to the Batteries 065AmpFloat Voltage 274 VoltsFinal Voltage 210VoltsCharging Characteristics Constant Voltage with 065A

limit with temperature compensationMaximum current drawn from the batteries 30Ampswhen the mains is not availableDeep Discharge Protection 206 VoltsBattery Internal Impedance Fault gt05 ohms

InputsAddressable LoopsMax Number 2Max Loop Load per loop 200 maMax Number of Addressable Devices per loop 150Class Change Operated by external volt free contact

24

CAUTIONRISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS

(Appendix page 113)

I max a

I min

I max b

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 25: CF2000 User Manual

OutputsConventional sounder circuitsNumber of sounder circuits 4Total sounder Load 10Amps (FH1204)Maximum Sounder Circuit Load 800mASounder Circuit Fuses (F1234) 16 Amp (Quick Blow)End of line resistor 6k8

Fire Routing EquipmentMax Load 60 maFused (PTC2) 100mA polyswitchEnd of Line resistor 6k8

Fire Protecting EquipmentMax Load 60 maFused (PTC4) 100mA polyswitchEnd of Line resistor 6k8

Fault Routing equipmentMax Load 30 maFused (PTC1) 100mA polyswitchEnd of Line resistor 6k8

Auxiliary RelaysThe auxiliary relays provide fused volt free change over contacts These contacts are not monitoredMax Load 24 Volts 1 AmpFuse (PTC5) 11 Amps polyswitch

Auxiliary 24V SupplyNominal Voltage 24 Volts plusmn10Fuse (PTC3) 300 mA PolyswitchMaximum current 30 mAThis output is not to be used for Fire protecting equipment or Fire alarm routing EquipmentAny power taken from the alarm system will effect the standby duration

RS485 Port (Mimic Repeater)This is a serial output port for driving CF2000 Repeater panels mimics etcThis output is short circuit protectedMax Cable Length 2KmMin Recommended cable size 1mmsup2 (Screened)

Mechanical SpecificationWeight including batteries 106KgWeight excluding batteries 53KgDimensions (Standard batteries) 400mm(L) x 320mm(H) x 170mm(D)Type of Material (backbox) Mild Steel (Power Coated)Type of Material (Facia) PCABSFlammability Rating UL 94 V0Total Number of knockouts 24Diameter of Knock out 20mm

TERMINAL BLOCKS

DO NOT USE EXCESSIVE FORCE WHEN TIGHTENING THE SCREWS ON THE TERMINAL BLOCK

Technical Specification

25

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 26: CF2000 User Manual

Optional Functions as per EN54 P2amp4

CF2000 is approved to EN54 Parts 2 amp 4 including all the following options which can be selected as required

PANEL INPUTS

Class Change ( OPTION NOT REQUIRED BY EN54)A pair of terminals are provided for class change By shorting these terminals together (eg Switch Time clock) the alarm will sound (Panel sounders + loop sounders only) The Panel will not indicate a Fire The alarm will cancel when the short circuit is removed

WARNING NO VOLTAGE SHOULD BE APPLIED TO THIS INPUT

PANEL OUTPUTS

Panel Sounders (OPTION 78 EN54 PT 2)Two pairs of outputs are provided ONLY polarised equipment should be usedEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 5) are fitted for correct operationThe total alarm load across all sounder outputs = 10AmpAll outputs are fused with 16 Amp Glass fuse Alarm devices should be spread equally across the 4 sounder circuitsWARNING DO NOT EXCEED THE RATED OUTPUT CURRENT

OUTPUT FIRE ALARM ROUTING EQUIPMENT (OPTION 79 EN54 PT 2)

This output which is fused and monitored using a 68k end of line resistor is used for the automatic transmission of the fire signals to fire alarm ROUTING equipment (eg Fire brigade) It operates by providing 24 Volt output to an auxiliary device ( eg relay)It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition the FRE LED will illuminate and will remain illuminated until the fire alarm is resetEnsure the polarity of the connections are observed at all times and end of line resistors (6K8 (5 ) are fitted for correct operation

OUTPUT TO FIRE ALARM PROTECTING EQUIPMENT ( OPTION 710 EN54 PT 2 Option A)

This output which is fused and monitored using a 68k end of line resisters used for the transmission of the fire signals to controls for automatic fire protecting equipment (eg Door released units etc)It operates by providing 24 Volt output to an auxiliary device ( eg relay)`

All Sounders must be polarised Both sounder circuits must Be terminated with a 6800 Ohm end of line resistor

26

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 27: CF2000 User Manual

It is current limited to 30 mA using a resettable polyswitch Class change and test conditions do not operate this output If operated under a fire alarm condition this output remains energised until the fire alarm is resetEnsure the polarity of the connections is observed at all times and end of line resistors ( 6K8 5 ) are fitted for correct operation

OUTPUT TO FAULT WARNING ROUTING EQUIPMENT ( OPTION 89 EN54 PT 2)

This output which is fused and monitored using 68k end of line resistor is used for the transmission of fault signals to fault warning routing equipment This output is monitored using 6k8 end of line resistor and it current limited to 30 mAUnder normal condition it operates by providing 12vdc which can be connected directly to a 12v auxiliary device(It is current limited to 30 mA)Under fault conditions or even if the CF2000 is powered down this output will be switch to O voltsEnsure the polarity of the connections is observed at all times and end of line resistor 6K8 (5) are fitted for correct operation

Delays to outputs (Option 711 of EN54pt 2)

The CF2000 has the option to delay the operation of panel sounders the fire routing equipment output and the fire protecting Equipment This delay is selectable using the CF2000 site installer download software The delay is configurable in increments of 1 minute up to a maximum of 10 minutesThis delay can be enabled and disabled at access level 2The CF2000 has the facility for a specific call point to override this delay by programming this call point via an input interface to provide an evacuate signal using CF2000 site Installer

Dependencies on more than one alarm signal - Type C(Option 7123 of EN54pt 2)

The CF2000 has the facility to inhibit the operation of the output sounders Output to Fire routing equipment and the output of the fire protecting equipment until one more confirmatory signals are received from different zones This feature is programmable using CF2000 Site Installer Software

Optional Functions as per EN54 P2amp4

Auxiliary Relay (OPTION NOT REQUIRED BY EN54)This output is a volt free contact which is protected by a polyswitch It is rated at 24 Volts DC 1Amp If operated under a fire alarm condition this output will remain energised until the fire panel is reset

DO NOT USE TO SWITCH MAINS VOLTAGE

AUXILIARY DC OUTPUT (OPTION NOT DEFINED BY EN54)

A 24 Vdc output is provided This output is protected by a polyswitch This output can be used to power fire or fault auxiliary equipment Please ensure that all equipments connected to this output will only draw current when a fire condition exists

WARNING- DO NOT EXCEED THE RATED OUTPUT CURRENT

MIMIC OUTPUT (OPTION NOT REQUIRED BY EN54)

This RS485 output is used to send data to a mimic display or a repeater panel The maximum distance is 2km

27

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 28: CF2000 User Manual

Networking (Option not required by EN54)

A B X Y

Network Card(Panel 1)

A B X Y

Network Card(Panel 2)

Network Cable

Up to sixty three CF2000 panels or passive repeaters can be networked together to operate as a single networked system To achieve this each panel must be fitted with a network card (supplied at additional cost)When operating as a networked system all fire and fault event information is displayed at every panel silencing and resetting of alarms can also be carried out from any panel on a networked system if panels are suitably configured

Networked panels are connected using a loop topology as illustrated

Networked panels can be used as active repeaters alternatively a low cost passive repeater is availableThis can either be connected to a loop of an individual panel or it can be connected to the network

The recommended network cable for the network connection between panels is an enhanced Firetuf cable Manufactured by Draka cables (part number )910234Screen continuity must be maintained throughout the entire network circuit including at each junction point The screen should only be earthed at the connection point provided at the first panel and not at any other point The screen or drain wire of the network cable should not be considered as a safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleevingWhere the network cable passes between buildings screen continuity should not be maintained from building to building A booster device must however be used irrespective of cable length and should be fitted at a suitable point in the link between buildings The cable screen should be connected to the earth of one panel in each building

28

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 29: CF2000 User Manual

External Connections

Mains Supply

The mains supply should be installed in accordance with the current edition of the IEE wiring regulations Connection to the mains supply must be via an isolating device (ega double pole isolating fuse rated at 2A In each case you have to comply with local regulations ) reserved solely for the fire alarm system The cover should be coloured red and labelled ldquoFIRE ALARM - DO NOT SWITCH OFFrdquo The isolating protective device should be secure from unauthorised operation and ideally installed in a securely closed box with a breakable cover

An additional warning label should be provided depending on whether-

a) The isolating protective device is fed from the live side of the main isolating device in which case the label on the isolating protective device should read in addition - ldquoWARNING THIS SUPPLY REMAINS ALIVE WHEN THE MAIN SWITCH IS TURNED OFFrdquo A further label should be placed on the main isolating device reading ldquoWARNING THE FIRE ALARM SUPPLY REMAINS LIVE WHEN THIS SWITCH IS TURNED OFF

Or

b) If the isolating protective device is fed from the dead side of the main isolating device a label should be fixed to the main isolating device reading ldquoWARNING THIS SWITCH ALSO CONTROLS THE SUPPLY TO THE FIRE ALARM SYSTEMrdquo

Cable SegregationAll cables for the fire alarm system should be segregated from any other cableswiringservices

29

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 30: CF2000 User Manual

The panel should be installed in a clean dry reasonably well ventilated place and not in direct sunlight Temperatures in excess of 40degC and below 5degC may cause problems if in doubt consult Cooper Fire Systems The panel should be located away from any potential hazard in a position where it is readily accessible to authorised staff and the fire services ideally on the perimeter of a building near a permanent entrance Mount the panel to the wall using the drill template provided Do not drill through the panel to the wall as dust will contaminate the circuitry

Installation Guide Never carry out insulation tests on cables connected to electronic equipment

DO NOT OVER TIGHTEN TERMINAL CONNECTOR SCREWS

Always use the correct type of cables specifically designed for the operation of fire detection and alarm circuits

Always adhere to volt drop limitation when sizing cables

Always observe polarity throughout Non colour coded conductors should be permanently identified

Screen continuity must be maintained throughout the entire loop circuit including at each junction point and at each device terminals are provided on each device to facilitate this

The screen should be earthed at the connection point provided at the CF2000 panel and not at any other point Both the loop start and the loop end must be connected to the appropriate earthing points Care must be taken to avoid connecting the screen to the earthed body of any metal devices enclosures or cable containment The screen or drain wire of the loop cables should not be considered as safety earth and therefore should not be connected to terminals marked with the earth symbol except at the panel and should not be insulated with green and yellow sleeving

CF2000 utilises intelligent soft addressing technology to greatly simplify the installation and commissioning processes Once the system has been installed and the autolearn menu selected the CF2000 control panel will automatically scan the detection loops and allocate each device with an address number corresponding with its position on the loop this avoids the traditional need for manual addressing of the system devices which is time consuming and provides a potential for error

It is of vital importance that accurate details are kept of the exact wiring route in order to determine which address has been allocated to each device

Installation

30

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 31: CF2000 User Manual

Fixing details

Read all the installation instructions before commencing with the installation The installation of this panel must be carried out by a suitably qualified trained person The installation must comply with IEE wiring regulations and with BS5839 part 1 2002

The electronic components within the fire panel are Static Sensitive Do not touch the electronics directly

Mounting the Backbox

The CF2000 can be flush mount or surface mounted

1 Surface Mount drill four holes and fix the backbox to the wall

2 Flush mounting the backbox requires a hole 310 x 355 with a depth of 117mm

Installing Cabling

Once the backbox is mounted the next stage is to install the power and loop cables and fit the glands

390mm 355mm

310mm

117mm

132mm

31

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 32: CF2000 User Manual

System Wiring

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

Any

300 S

eries

Analo

gue D

ete

ctor

can b

e C

onnect

ed t

o t

he L

oop

Upto 150 Analogue Addressable Devices

32

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 33: CF2000 User Manual

System Wiring ( Optional Board)

EE

EE

EE

+-

-+

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AD

DR

ES

SA

BLE

CA

LLP

OIN

TS

AN

ALO

GU

E S

EN

SO

RS

AN

ALO

GU

E S

EN

SO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

D

ET

EC

TO

RS

CO

NV

C

ALLP

OIN

TS

LO

OP

1LO

OP

2 C

ON

V

CA

LLP

OIN

TS

S+

S+

F-

F-

F+

F+

S-

S-

EE

EE

--

--

++

++

EOLM-1

EOLR

EOLM

EOLR

Upto 32 AnalogueAddressable Callpoints

Upto 32 AnalogueAddressable Callpoints

Upto 20 CoventionalDetectors

Upto 20 CoventionalDetectors

Upto 32 CoventionalCallpoints

Upto 32 CoventionalCallpoints

Upto 99 Analogue Addressable Devices

Upto 99 Analogue Addressable Devices

This boards is used to extend the flexibility of the CF2000 by splitting each loop into four circuits One circuit will allow the use of 99 addressable devices wired in a loop The second circuit can accommodate up to 32 addressable Call point in a spur configuration Up to 32 conventional call point can be wired in the third circuit where the line is monitored using End of Line Resistor and finally the forth circuit has a maximum capacity of up to 20 Conventional detectors again the line is monitored with an active end of line device EOLM-1

33

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 34: CF2000 User Manual

Commissioning CF2000

Section 2

34

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 35: CF2000 User Manual

Updownloading using PC Software

The PC Software enables the address location text device type and any comments to be downloaded to the CF2000 panels

The software can download to all 63 networkable Panels

The PC is connected to each Panel on the network in turn All data for the Panel is downloaded

For networked systems panels are identified by panel number P1 P2 etc

Commissioning

35

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 36: CF2000 User Manual

PC Comissioning Software

Device Input Programming

Fire -gt panel reports fire from deviceFault -gt panel reports fault from deviceReset -gt panel resetsSilence -gt silence all currently active soundersPre-Alarm -gt panel reports pre-alarm from device

Non-Latching-gt device wont latch in alarm condition used in conjunction with isolates

Optical-Heat -gt mode changes between heat or optoheat mode

Heat -gt mode changes between Heat A1R and Heat CS

Isolate Zone Address

user can define between zones or addresses to be isolated on activation of the deviceThe isolate list button enables the user to enter upto 8 unique zones or addresses

If non-latching has been enabled Isolated devices can be un-isolated as the triggered devicereturns to normal operation (a call point keyswitch is an example for this application)

36

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 37: CF2000 User Manual

PC Comissioning Software

Device Outputs

Delay configurationThe output of a device when triggered can be delayed - based on a user defined value in minutesThis programming option is enabled when a value other than zero is entered inside the Delay window

Delay OverrideThis option is a manual intervention override when enabled (check in box) the delay can be overridden from any call point on the loop when triggered

37

One of these will be ticked

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 38: CF2000 User Manual

PC Comissioning Software

Panel Outputs

Dependence detectionEach panel output can be assigned a unique list of zones derived from the zones available on the loop to activate this output two unique zones from this list have to be be in fire or alternatively any zone outside this list will trigger the output also When the dependence box is checked - the Allocate device button allows the user to populate this list

38

Ticked by Default

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 39: CF2000 User Manual

Panel Fault Finding

NO

CN

C

FA

ULT

R

ELA

Y+

24V

OP

FIR

E R

EF

IRE

PE

CLA

SS

CH

AN

GE

SO

UN

DE

RC

IRC

UIT

1LO

OP

1LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

S-

- +

26V

++

--

+-

+-

Tx-

Tx+

S+

F-

F+

S-

+ 1

-+

2 -

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

V

V

V

V

V

V

F+ V

V

V

V

V

V

V

V

V

W

W

= 28V (Open Circuit No Input)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

= -06V Mon +28V Fire (Depends on Programming)

=0V (No Data)

See Scope Plots for Monitoring Conditions

= OC Normal SC Fire

= +55V plusmn 05V (No Printer Attached)

= SC Normal OC Fire

= 12V No Fault 0V (short CCT) Fault

= 285V (No Load Connected)

= -O6V-No Fire 28V Fire No FiresSee Scope Plots forMonitoring Condition

See Protocol Section for Scope Plots

= -O6V-No Fire 28V Fire

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

= 22V (Device Fitted) 0V (Unused)

39

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 40: CF2000 User Manual

Byte 1 Byte 2 Byte 3

Pa

rity

Command

2ms 300us

300us

Start

Fig 1 Full Protocol Format (Not including Repeaters)

Panel to Device Device to Panel

Response8 bits

ID5 bits

Flags3 bits

Address8 bits

Loop Current

24vtyp

75v0v

Mode

See Fig 4 for detail

11 ms

Each Packet of Comms above must be separated by a gap of 20ms minimum where the line is held at 24v

Last Bit Only136 ms

Protocol Format

Normal Communications to DevicesWith the command bits set for the Normal command and the MSB of the three mode bits set at 0 this shortened version of the Normal communications to each device allows the analogue reply or status from each device to be read This format of communication is generally used throughout all background supervision of the addressable loop

Alarm Interrogate CommandThis command is seen by all devices on the loop so no address byte is required and is periodically sent out during normal communications This command allows any device experiencing an alarm condition to respond with call points given the highest priority reporting their address This causes the control panel to break off from general background supervision of the loop and focus directly on the device in question

Full Protocol FormatWith the command bits set for the Normal command and the MSB of the three mode bits set at 1 the long version of the Normal communications can be sent to any device This would normally be done by the panel following a response to the Alarm Interrogate command allowing the panel to check the device address ID and confirm that the analogue reply or status is truly an alarm condition before actioning the panel sounder outputs for example

Viewing the Voltage and Current waveforms at the panelLoop 1 Using a Digital Storage Oscilloscope connect one channel to R84 on the Loop Driver Card probe 0V clip to the Bottom side of the resistor IP to the out-board side This will display the loop currentConnect the other channel to Loop 1 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

Loop 2 Using a Digital Storage Oscilloscope connect one channel to R82 on the Loop Driver Card probe 0V clip to the Bottom side of the resistorThis will display the loop currentConnect the other channel to Loop 2 S+ terminal on the main mother board DO NOT connect the 0v clip of this probe

40

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 41: CF2000 User Manual

Panel Controls amp Indicators

Section 3

41

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 42: CF2000 User Manual

1 LCD Display2 System LEDrsquos3 Zonal LEDs4 Buttons

Panel Controls amp Indicators

LED Name Function Action1 Power On Shows Panel is On (Mains Healthy) Check Indicator is Illuminated

2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure

3 General Fault Monitors Devices for Faults eg Smoke detectorsSounders Report to System Supervisor

4 General Disable Monitors panel for disablements Report Fault to Service Dept

5 Test SupervisorEngineer is Testing the System Check with System Supervisor

6 Delay Active Part of the System has been Disabled Check with System Supervisor

7 FRE On Fire Routing Equipment relay activated Report to System Supervisor

8 FPE Indicateds Fire Protecting Equipment Status Check with System Supervisor

9 Power Fault Indicated PSU Fault Check with System Supervisor

10 Sounder Indicates the Sounder Status Check with System Supervisor

11 FRE Indicateds Fire Routing Equipment Status Check with System Supervisor

12 System Fault Panel has a Fault Report to System Supervisor

42

12

3

4

FPE

1

5

7

26

8

3

4

9

10

11

12

FPE

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 43: CF2000 User Manual

System Healthy

System Healthy

1 Zone(s) Active

Reset

Cancel MuteOK

hhmmss ddmmyy

000AC

CF2000 is operated via an 8 button keypad The default healthy screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

43

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 44: CF2000 User Manual

View Event

The View Events screen is shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Reset

Cancel MuteOK

View Events

Fire

View Pre-Alarm

View Fault

View Disable

View Log

Scroll through the events list using the scroll buttons as shown

Press OK

44

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 45: CF2000 User Manual

Fire Event

View Fire

The Fire screen is shown below From this screen all the panels functions can be operated Press any key to prompt the passcode screen

11

Time PA LP AD ZN Type

Fire Listi

45

FPE

Power ON Test

FIRE

General FAULT

General DISABLE

FRE ON

Delay ACTIVE

Power FAULT

Sounder

FRE

System FAULT

DisableFault

DisableFault

FPE

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 46: CF2000 User Manual

View Fires

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Fire

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Fire screen

Press OK

Time PA LP AD ZN Type

Fire Listi

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

46

FPE

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 47: CF2000 User Manual

FPE

View Pre-Alarm

The View Fires screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Pre-Alarm screen

View Pre-Alarm

i Pre Alarm List

Time TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

47

Press OK

2359 01 2 009 1 Repeater

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 48: CF2000 User Manual

FPE

View Fault

The View Fault screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Fault screen

Press OK

View Faults

i Fault List

Time

2359 01 2 009 1 Repeater

TypePA LP AD ZN

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

48

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 49: CF2000 User Manual

FPE

View Disabled(Address)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Address

141

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

PTO

49

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 50: CF2000 User Manual

FPE

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Enabled and Disabled

Reset

Cancel MuteOK

Switch between Loop 1 and Loop2 byusing these buttons Press OK to select

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Disabled Devices (67)

A Device Status001 HtA1R

HtA1R

HtA1R

HtA1R

002

003

004

DISABLED

DISABLED

DISABLED

DISABLED

View Disabled(Address)

50

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 51: CF2000 User Manual

FPE

View Disabled(Zone)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled Zone

142

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disabled Zones (000)

Zone001

StatusDISABLED

51

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 52: CF2000 User Manual

FPE

View Disabled (IO)

The View Disabled screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Disabled

Disabled IO

143

14

1

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Disable Panel IO

Aux RelayFRE

ENABLED

ENABLEDENABLEDENABLEDENABLEDENABLED

FPESounder 1Sounder 2Delay

52

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 53: CF2000 User Manual

FPE

View Log

The View Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

View Events

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

View Log

View

151

15

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

i

Time Event PA LP AD Type

Log (000)

53

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 54: CF2000 User Manual

FPE

Operations (Soft Reset)

The Soft Reset screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Soft Reset screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Soft Reset

31

Soft Reset

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

54

OR Press 8

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 55: CF2000 User Manual

FPE

Operations (Evacuate)

The Evacuate screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Evacuate screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Evacuate

32

Evacuate Activated

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

55

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 56: CF2000 User Manual

FPE

Operations (Silence Alarms)

The Silence Alarms screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Silence Alarms screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Silence Alarms

33

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

56

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 57: CF2000 User Manual

FPE

Operations (Lamp Test)

The Lamp Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Lamp Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Lamp Test

34

Lamp Test

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Press OK

57

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 58: CF2000 User Manual

FPE

Operations (Weekly Test)

The Weekly Test screen is accessed as shown below The Operations screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the events screen by default press the Scroll Down button until the Weekly Test screen is shown as illustrated below Press OK and scroll through the list of options using the UP and Down arrow buttons and pressing OK to select

Enter Passcode

Operations

3

Weekly Test

Weekly Test

Waiting for Fire

35

Soft Reset

Reset

Cancel MuteOK

Scroll through the operations list using the scroll buttons as shown

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Put Fire on Systemor Time Out

Press OK

58

Features outside EN54 spec

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 59: CF2000 User Manual

Access Level 2

Section 4

59

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 60: CF2000 User Manual

FPE

Commissioning

The Commissioning screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Commission

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Commission screen

Press OK

PC to Panel

Panel to PC

Autolearn

12

11

1

13

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

60

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 61: CF2000 User Manual

FPE

Panel Settings (Erase Log)

The Erase Log screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the View Disabled screen

Press OK

Press OK

Press OKErase Log

Erase Entire Log

Erase Entire Log

Erasing

21

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

61

OK to continueCANCEL to exit

OK to continueCANCEL to exit

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 62: CF2000 User Manual

FPE

Panel Settings (Change Password)

The Change Password screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Password screen

Press OKChange Password

Enter New Password

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

62

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 63: CF2000 User Manual

FPE

Panel Settings (Change Language)

The Change Language screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change Language screen

Press OKChange Language

23

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

English

63

FrenchItalianPortugese

Select Language

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 64: CF2000 User Manual

FPE

Panel Settings (Date Time)

The Change DateTime screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Change DateTime screen

Press OKSet DateTime

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Change Date

Change Hours

OK confirms changeUse updownleftright

0938

64

Press OK

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 65: CF2000 User Manual

FPE

Panel Settings (Systems Details)

The System Details screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Panel Settings

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the System Details screen

Press OKSystem Details

25

2

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Scroll to other details

System Details

Prog Ver V01010011-11-050x0000A5B70x0000A5B7

DateChksumCDRCDR Csum

65

Press OK

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 66: CF2000 User Manual

FPE

Networking (Panel Address)

The Panel Address screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Panel Address screen

Press OKPanel Address

31

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

66

Using the curser keys to choose the number

Press OK

Press OK

Press OK

0 00

Panel address updated

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 67: CF2000 User Manual

FPE

Networking (Panels in Network)

The Panels in Network screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Use the curser keys to choose the number

Press OK

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

67Press OK

Number of panels updated

Press OKPanels in Network

32

Press OK

0 00

Using to scroll keys show to the left scroll to the Panels in Network screen

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 68: CF2000 User Manual

FPE

Networking (Network Messaging)

The Network Messaging screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Networking

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Network Messaging screen

3

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

68

Press OKNetwork Messaging

33

Press OK

Network Messaging

Soft resetEvacuate ENABLED

ENABLEDENABLEDENABLEDENABLED

SilenceFireFaultPre-Alarm

ENABLED

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 69: CF2000 User Manual

FPE

Testing (Test Device)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Device screen

Press OKTest Device

41

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not in Test

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Devices in Test

AD Device Status

69

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 70: CF2000 User Manual

FPE

Testing (Test Zone)

The Test Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Zones screen

Press OKTest Zone

42

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Use the scroll up and down buttonsto highlight the device and the OKbutton to switch between Test and Not Test

Zones in Test

Zone Status

70

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 71: CF2000 User Manual

FPE

Testing (Test Sound Levels)

The Test Sound Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Test Sound Levels screen

Press OKTest Sound Levels

43

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Testing Sounder Levels

15secs ON - 30secs OFF

71

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 72: CF2000 User Manual

FPE

Testing (One Man Walk Test)

The One Man Walk Test screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the One Man Walk Test screen

Press OK

Press OK

One Man Walk Test

One Man Walk Test

44

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Testing

Status Disabled

72

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 73: CF2000 User Manual

FPE

Testing (Global Flashing LED)

The Global Flashing LED screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Global Flashing screen

Press OKGlobal Flashing LED

45

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

73

Press OK

Press OKGlobal flashing LEDs

Status Disabled

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 74: CF2000 User Manual

FPE

Testing (Analogue Levels)

The Analogue Levels screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Testing

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Analogue Levels screen

Analogue Levels

46

4

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Analogue valve sceen

Device

Use the scroll up and down buttonsto highlight the device and the OKto view Device Values

74

Address

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 75: CF2000 User Manual

FPE

Device Config (Add Device)

The Add Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Add Device

51

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Searching

75

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 76: CF2000 User Manual

FPE

Device Config (Delete Device)

The Delete Device screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Delete Device

52

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

Press OK

Loop 1 Loop 2

Switch between Loop 1 and Loop2 byusing the sideways scroll buttons shownto the left and press OK to select

Device List

Address DeviceUse the scroll up and down buttonsto highlight the device and the OKto select device

76

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 77: CF2000 User Manual

FPE

Device Config (Configure Zones)

The Configure Zones screen is accessed as shown below The events screens are accessed from the healthy screen by first pressing any button You will then be prompted to enter the passcode which will show the screen below by default Press OK and scroll through the list of events using the UP and Down arrow buttons

Device Config

Enter Passcode

Reset

Cancel MuteOK

Scroll through the events list using the scroll buttons as shown

Using to scroll keys show to the left scroll to the Add Device screen

Not Implemented

53

5

System Healthy

1 Zone(s) Active

hhmmss ddmmyy

000AC

77

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 78: CF2000 User Manual

Appendix

Section 4

78

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 79: CF2000 User Manual

Spur Isolator CSI350

Installation

1 Fit the unit in position2 Connect the unit according to the diagram below

NotesA Spur Isolator must be used when making spurs from the analogue addressable panel loop Without this unit the self addressing features of the system will not function correctlyNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 For maximum spur length load see BS5839 Pt120023 This unit can only be used with Cooper CAB300 detector bases and compatible

sensors

E

OUT

IN

SPUR

E

E

-

-

-

+

+

+

ANALOGUE ADDRESSABLE LOOP

NO END OF LINE RESISTOR REQUIRED

79

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 80: CF2000 User Manual

L N E E + - E + - E + - E + - E E-

--

-+

++

+

NO

BATT

C NC

BACK UP BATTERY

230V AC MAINS

ANALOGUEADDRESSABLE LOOP

OUT IN

6k8 6k8 6k8 6k8

FIRE RELAY

Installation

1 Remove the cover of the unit2 Fit the back-plate in position and pass the wires into it taking care not to

damage the circuit board3 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for detailsThis unit requires a permanent 230V AC supply

Standard Connections

4 Way Sounder Controller CSC354

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistors must always be fitted even if the sounder circuits are Unused

80

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 81: CF2000 User Manual

E

LOOPOUT IN CALL

POINTZONE

DETECTOR ZONE

E E E- - - -+ + + +

- OUT +

- IN +

- OUT +

- IN +

12K

EOLM-1

Analogue Addressable Loop

Zone Monitor Unit CZMU352

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 This unit can only be used with CDBB300 detector base and compatible detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-1 (supplied) 7 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

81

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 82: CF2000 User Manual

Shop Monitor Unit CSUM355

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E

LOOP

OUT IN CALL POINTZONE

DETECTOR ZONE

SOUNDER

EXTERNAL PSU MONITOR

24VEXTERNAL PSU INPUT

1 2

FIRERELAY

E E E

E

ENO

FaultContact NO

24V DC OUTPUTPOWER SUPPLY UNIT

24VOP

C NC- - - -+ + + +

+

+

-

-

+

+

+

+

-

-

-

-

- OUT +

- IN +

- OUT +

- IN +

6K8 12K 12K

12K

EOLM-1

Analogue Addressable Loop

Notes1 This unit can only be used with CDBB300 detector base and compatible

detectors2 Only connect cable screen to its adjacent earth terminal3 The end of line resistor must always be fitted even if the spur is unused4 Maximum spur length - See BS5839 Pt12002 for Zone Coverage5 Maximum number of call points allowed is unlimited6 Detector zone end of line device is EOLM-17 Callpoint zone has end of line resistor

Callpoints can be connected with detectors on detector zone if preferred

82

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 83: CF2000 User Manual

1 way Input Output Unit CMIO353

Installation1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-

box3 Fit the back-box in position and pass the wires into it4 Connect the unit according the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

E E

22k

5k6

E C NC NO

IN OUT

- - -+ + +

Analogue Addressable Loop

Volt-Free Output 230V Rated

SPURINPUT

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the spur is unused

83

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 84: CF2000 User Manual

+

S+

F

F+

S

_

_

__

_

_

_

_

_

_

Remote IndicatorLED(optional)+VIN

- VE COM OUT

Supply Voltage 18 - 30 V DCCable Size 05 - 25mmsup2Recommended cable types FIRETUFFP200 or MICCMounting Hole Centres 50 - 80mm

Wiring Hints

Each terminal is suitable for clamping up to 2 wires Clamping of 2 wires of very different diameters under one screw is not

recommended Suitable for mounting to mounting boxes with 50-80mm fixing centres

General

If difficulty is experienced when mounting the sensor this may be due to the following

Wiring causing an obstruction - move or shorten wires Although the base is tolerant to uneven mounting surfaces a very uneven

surface may cause the base to deform when the mounting screws are tightened down - loosen screws to reduce this or slide base to a flat position

WARNING DO NOT USE HIGH VOLTAGE TESTERS WHEN SENSORS OR CONTROL PANEL ARE CONNECTED TO THE SYSTEM

C

F2000

Analo

gue A

ddre

ssable

F

ire A

larm

Panel

Earth screen of cable to be continuous between sensors

Loop S

tart

Loop F

inis

h

- VE COM IN

SensorBase Wiring CAB300

84

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 85: CF2000 User Manual

NO

CN

C

FA

ULT

R

EL

AY

+ 2

4V

OP

FIR

E R

EF

IRE

PE

CL

AS

SC

HA

NG

E

SO

UN

DE

RC

IRC

UIT

1L

OO

P 1

LO

OP

2 A

UX

RE

LA

Y

LO

OP

CIR

CU

ITS

0V

S+

F-

F+

S-

- +

26

V+

+-

-+

-+

-T

x-T

x+S

+F

-F

+S

-+

1 -

+ 2

-

SO

UN

DE

RC

IRC

UIT

2 M

IMIC

R

EP

EA

TE

R

+ 1

-+

2 -

System Wiring

Any

300 S

eries

Analo

gue S

enso

r ca

n b

e C

onnect

ed t

o t

he L

oop

85

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 86: CF2000 User Manual

Internal wall Sounder CAS381

Installation1Fix to mounting surface using two suitable screws - the rear gasket fits underneath the base and the sounder gasket fits inside the base

Connection

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

NOTE

Care should be taken to ensure the cable does not put stress on the circuit board

E E

IN OUT

- -+ +

Analogue Addressable Loop

87

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 87: CF2000 User Manual

IP66 Wall Sounder CAS381WP

Installation1Drill required holes for the cable gland fixing

2Drill out the required fixing holes

3Fix to mounting surface using two suitable screws

Connections

WARNING Do NOT use high voltage testers if ANY equipment is connected to the system Earth scrreen must be continuous along entire length of loop

E E

IN OUT

- -+ +

Analogue Addressable Loop

86

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 88: CF2000 User Manual

+ +- - + +- -

S+

F

F+

S

_

_

__

_

_

_

_

_

_

C

F2

00

0A

na

log

ue

Ad

dre

ssa

ble

F

ire

Ala

rm P

an

el

Lo

op

Sta

rtL

oo

p F

inis

h

Base Sounder (CAS380 + CASC)

Supply Voltage 17 ~ 32 VdcCable Size type 05 ~ 25mm FIRETUF FP200 or MICCStandby current lt 320 uAOperating temperature -10 to +55 degrees C (95RH)

Sound output +-3dB Low volume 84dB lt4mA(set by panel) Medium volume 92dB lt8mA

High volume 95dB lt12mA

Tones Continuous 910Hz(set by panel) Pulsed 910Hz 0Hz pulse 1Hz

Two tone 610 910Hz 1Hz cycle Slow whoop 500-1200Hz in 35 seconds 05secs gap

88

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 89: CF2000 User Manual

3 way Input output unit CIO351

E E

22k 22k

5k6 5k6

- - - - -+ + + + +

LOOPIN OUT

ANALOGUE ADDRESSABLE LOOP

INPUTS

OUTPUTS

NO NO NOC C CNC NC NC

22k

5k6

Installation

1 Separate the two halves of the unit2 Drill out (or knock out) the required cable entries in the surface mounting back-box3 Fit the back-box in position and pass the wires into it4 Connect the unit according to the diagram below

NotesNo addressing of the interface is required See control panel operation for details

Standard Connections

Notes1 Only connect cable screen to its adjacent earth terminal2 The end of line resistor must always be fitted even if the inputs are unused3 Monitored inputs can detect open or short circuit faults4 Output relays are volt-free contacts and are not monitored

89

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 90: CF2000 User Manual

Loop Powered Beacon (CAB382)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

Connection Details

Earth screen of cable to be continuous between beacons

Warning

Do NOT use high voltage testers if any equipment is connected to the system

90

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 91: CF2000 User Manual

Call Point (CBG370 CBG370S CBG370WP)

E E

IN OUT

- -+ +

Analogue Addressable Loop

LOOP IN LOOP OUT

91

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 92: CF2000 User Manual

92

PINSTCF2000

CE Marking

0832 ndash CPD ndash 1089 0832 ndash CPD ndash 1089714h02 714h02

EN 54-2 1997 amp A12006

CF2000Control and indicating equipment for fire detection and fire

alarm systems for buildingsEN 54-2 Clause

Options Provided

78 Output to fire alarm devices791 Output to fire alarm routing equipment7101 Output to automatic fire protection equipment (type A)711 Delays to outputs7123 Dependencies on more than one alarm signal-Type C713 Alarm counter89 Output to fault routing equipment95 Disablement of each point10 Test condition

Other technical data see Doc PR202-50-502 held by themanufacturer

EN 54-4 1997 amp A12002 A22006

CF2000Power supply equipment for fire detection and fire alarm

systems for buildings

Other technical data see Doc PR202-50-502 held by themanufacturer

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

Cooper Lighting and Safety LtdWheatley Hall Road

DoncasterSouth Yorkshire

DN2 4NB

09

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

ERC T I FN ICO AI TT

IN OE NV E BR OP AS RS DOL

LPCB

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
Page 93: CF2000 User Manual

Battery Disposal Instructions

Although batteries contain lead and small amounts of antimony and arsenic they are safe if handled according to the accompanying guide The battery cells must not be dismantled as this involves several hazards which are best handled under controlled conditions using specialised equipment No attempt should be made to repair any batteries they should be treated as disposable when they have outlived their use

Batteries must be disposed of in accordance with current waste disposal and pollution legislation and in particular The Environment Protection Act 1990 Special Waste Regulation 1996 It is recommended that the following authorities are contacted before any attempt is made to dispose of batteries Environment Agency Local office Local Authority Environmental Health or Waste Handling department

93

PINSTCF2000

  • Page 1
  • 2 Changed
  • Page 3
  • Page 4
  • Page 5
  • 6 Changed
  • Page 7
  • 8 Changed
  • 9 Changed
  • Page 10
  • Page 11
  • 12 Changed
  • Page 13
  • Page 14
  • 15 Changed
  • 16 Changed
  • 17 Changed
  • 18 Changed
  • Page 19
  • 20 changed
  • Page 21
  • Page 22
  • Page 23
  • 24 Changed
  • 25 changed
  • Page 26
  • Page 27
  • 28 04-08
  • 29 changed
  • 30 04-08
  • 31 04-08
  • Page 32
  • Page 33
  • 34 changed
  • 35 changed
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • 42 changed
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • 79 changed
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93