certificate of analysis - soothing solutions
TRANSCRIPT
Certificate of Analysis1500MG FULL SPECTRUM TINCTUREN/AMatrix: N/A Page 1 of 7
Soothing Solutions8340 Lakewood Ranch Blvd.BradentonFlorida, United States [email protected]
SAMPLE:DA90604009-006METRC/Biotrack#4 Harvest/Lot ID: 1
Batch#: 1, Sample Size: 12 -gramsOrdered: 05/30/19 Sampled:05/30/19
Completed: 06/06/19 Expires: 06/06/20Sampling Method: SOP Client Method
Image Safety
Pesticides - PassedMicrobials - PassedMycotoxins - PassedHeavy Metals - PassedTerpenes - TestedResidual-Solvents - PassedFilth - PassedWater Activity - NOT TestedMoisture - NOT Tested
Cannabinoids
0.119%Total THC
5.840%Total CBD
35.7 mgTHC/Container
1753.05 mgCBD/Container
CannabinoidsAnalyte Weight(%) mg/gD9-THC 0.119 1.190
THCa ND ND
TOTAL THC 0.119 1.190
CBD 5.840 58.400
CBDa ND ND
TOTAL CBD 5.840 58.400
CBN ND ND
CBDV 0.029 0.290
D8-THC ND ND
THCV ND ND
CBG 0.077 0.770
CBGa ND ND
CBC 0.126 1.260
TOTAL CANNABINOIDS 6.191 61.910
0.119 ND
5.840
ND ND 0.029 ND ND 0.077 ND 0.126
D9-THC THCa CBD CBDa CBN CBDV D8-THC THCV CBG CBGa CBC
4131 SW 47th AVENUE SUITE1408DAVIE, FL [email protected] ___________________
Jorge SegredoLab Director
State License # n/aISO Accreditation #97164
This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or productanalyzed. Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error.IC=In-control QC parameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit OfQuantitation (LoQ) are terms used to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels areState determined thresholds for human safety for consumption and/or inhalation.
Certificate of Analysis1500MG FULL SPECTRUM TINCTUREN/AMatrix: N/A Page 2 of 7
Soothing Solutions8340 Lakewood Ranch Blvd.BradentonFlorida, United States [email protected]
SAMPLE:DA90604009-006METRC/Biotrack#4 Harvest/Lot ID: 1
Batch#: 1, Sample Size: 12 -gramsOrdered: 05/30/19 Sampled:05/30/19
Completed: 06/06/19 Expires: 06/06/20Sampling Method: SOP Client Method
Terpenes Test result %alpha-Cedrene ND alpha-Humulene ND alpha-Pinene ND alpha-Terpinene ND beta-Myrcene ND beta-Pinene ND Borneol ND Camphene ND Camphor ND Caryophyllene oxide ND Cedrol ND alpha-Bisabolol ND Isopulegol ND cis-Nerolidol ND 3-Carene ND Fenchyl Alcohol ND Hexahydrothymol ND Eucalyptol ND Isoborneol ND Farnesene ND Fenchone ND gamma-Terpinene ND Geraniol ND Geranyl acetate ND Guaiol ND Limonene ND Linalool ND Nerol ND Ocimene ND alpha-Phellandrene ND Pulegone ND Sabinene ND Sabinene hydrate ND Terpineol ND Terpinolene ND trans-Caryophyllene ND trans-Nerolidol ND Valencene ND Total 0
4131 SW 47th AVENUE SUITE1408DAVIE, FL [email protected] ___________________
Jorge SegredoLab Director
State License # n/aISO Accreditation #97164
This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or productanalyzed. Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error.IC=In-control QC parameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit OfQuantitation (LoQ) are terms used to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels areState determined thresholds for human safety for consumption and/or inhalation.
Certificate of Analysis1500MG FULL SPECTRUM TINCTUREN/AMatrix: N/A Page 3 of 7
Soothing Solutions8340 Lakewood Ranch Blvd.BradentonFlorida, United States [email protected]
SAMPLE:DA90604009-006METRC/Biotrack#4 Harvest/Lot ID: 1
Batch#: 1, Sample Size: 12 -gramsOrdered: 05/30/19 Sampled:05/30/19
Completed: 06/06/19 Expires: 06/06/20Sampling Method: SOP Client Method
Pesticides LOQ Action Level Result Units TypeDaminozide 0.02 1 ND ppm Plant growth regulatorAcephate 0.01 0.4 ND ppm InsecticideFlonicamid 0.01 1 ND ppm Pyridine Insecticide, AphicideOxamyl 0.01 1 ND ppm Carbamate Insecticide, Acaricide,
NematicideMethomyl 0.01 0.4 ND ppm Carbamate Insecticide, Acaricide,
MetaboliteThiamethoxam 0.01 0.2 ND ppm Neonicotinoid InsecticideImidacloprid 0.01 0.4 ND ppm Neonicotinoid InsecticideDimethoate 0.01 0.2 ND ppm Organophosphate Insecticide,
Acaricide, MetaboliteAcetamiprid 0.01 0.2 ND ppm InsecticideThiacloprid 0.01 0.2 ND ppm Neonicotinoid Insecticide,
MolluscicideAldicarb 0.02 0.4 ND ppm Insecticide, NematicideDichlorvos 0.05 0.1 ND ppm Organophosphate Insecticide,
Acaricide, MetabolitePropoxur 0.01 0.2 ND ppm Carbamate Insecticide, AcaricideCarbofuran 0.01 0.2 ND ppm Insecticide, NematicideCarbaryl 0.01 0.2 ND ppm InsecticideImazalil 0.01 0.2 ND ppm Imidazole FungicideMetalaxyl 0.01 0.2 ND ppm Phenylamide FungicideChlorantraniliprole 0.01 0.2 ND ppm InsecticidePhosmet 0.01 0.2 ND ppm Organophosphate Insecticide,
AcaricideSpiroxamine 0.01 0.4 ND ppm Morpholine FungicideNaled 0.01 0.5 ND ppm Organophosphate Insecticide,
AcaricideMethiocarb 0.01 0.2 ND ppm Carbamate Insecticide,
Molluscicide, Bird repellentAzoxystrobin 0.01 0.2 ND ppm FungicidePaclobutrazol 0.01 0.4 ND ppm Triazole Plant growth regulator;
FungicideMalathion 0.01 0.2 ND ppm Organophosphate Insecticide,
AcaricideMyclobutanil 0.01 0.2 ND ppm Triazole FungicideBifenazate 0.01 0.2 ND ppm InsecticideSpirotetramat 0.02 0.2 ND ppm Tetramic acid InsecticideEthoprophos 0.01 0.2 ND ppm Insecticide, NematicideFenoxycarb 0.01 0.2 ND ppm Carbamate InsecticideKresoxim-methyl 0.01 0.4 ND ppm Strobilurin Fungicide, BactericideTebuconazole 0.01 0.4 ND ppm Triazole FungicideDiazanon 0.01 0.2 ND ppm Organophosphate Insecticide,
Acaricide, Repellent
4131 SW 47th AVENUE SUITE1408DAVIE, FL [email protected] ___________________
Jorge SegredoLab Director
State License # n/aISO Accreditation #97164
This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or productanalyzed. Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error.IC=In-control QC parameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit OfQuantitation (LoQ) are terms used to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels areState determined thresholds for human safety for consumption and/or inhalation.
Certificate of Analysis1500MG FULL SPECTRUM TINCTUREN/AMatrix: N/A Page 4 of 7
Soothing Solutions8340 Lakewood Ranch Blvd.BradentonFlorida, United States [email protected]
SAMPLE:DA90604009-006METRC/Biotrack#4 Harvest/Lot ID: 1
Batch#: 1, Sample Size: 12 -gramsOrdered: 05/30/19 Sampled:05/30/19
Completed: 06/06/19 Expires: 06/06/20Sampling Method: SOP Client Method
Pesticides LOQ Action Level Result Units TypePropiconazole 0.01 0.4 ND ppm Triazole FungicideClofentezine 0.01 0.2 ND ppm Tetrazine AcaricideSpinosad (Spinosyn A) 0.01 0.2 ND ppm InsecticidePrallethrin 0.05 0.2 ND ppm Synthetic pyrethroid InsecticideTrifloxystrobin 0.01 0.2 ND ppm Strobilurin FungicidePiperonyl butoxide 0.01 3 ND ppm Cyclic aromatic; Performance
enhancer, SynergistChlorpyrifos 0.01 0.2 ND ppm Organophosphate InsecticideHexythiazox 0.01 1 ND ppm Carboxamide AcaricideEtoxazole 0.01 0.2 ND ppm Diphenyl oxazoline AcaricideSpiromesifen 0.01 0.2 ND ppm Tetronic acid InsecticidePyrethrins (Pyrethrin I) 0.01 1 ND ppm InsecticideFenpyroximate 0.01 0.4 ND ppm Pyrazolium Acaricide, InsecticidePyridaben 0.01 0.2 ND ppm Pyridazinone Insecticide, AcaricidePermethrins 0.05 0.2 ND ppm Pyrethroid InsecticideAbamectin B1a 0.02 0.5 ND ppm InsecticideEtofenprox 0.01 0.4 ND ppm Pyrethroid InsecticideBifenthrin 0.01 0.2 ND ppm Acaricide, InsecticideFludioxonil 0.01 0.4 ND ppm Phenylpyrrole FungicideFipronil 0.02 0.4 ND ppm Phenylpyrazole InsecticideCypermethrin 0.02 1 ND ppm Pyrethroid Insecticide, Veterinary
substanceMevinphos 0.01 0.1 ND ppm Organophosphate Insecticide,
AcaricideDimethomorph 0.01 0.1 ND ppm Morpholine FungicideCoumaphos 0.01 0.2 ND ppm InsecticideSpinosad (Spinosyn D) 0.01 0.2 ND ppm Insecticide
4131 SW 47th AVENUE SUITE1408DAVIE, FL [email protected] ___________________
Jorge SegredoLab Director
State License # n/aISO Accreditation #97164
This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or productanalyzed. Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error.IC=In-control QC parameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit OfQuantitation (LoQ) are terms used to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels areState determined thresholds for human safety for consumption and/or inhalation.
Certificate of Analysis1500MG FULL SPECTRUM TINCTUREN/AMatrix: N/A Page 5 of 7
Soothing Solutions8340 Lakewood Ranch Blvd.BradentonFlorida, United States [email protected]
SAMPLE:DA90604009-006METRC/Biotrack#4 Harvest/Lot ID: 1
Batch#: 1, Sample Size: 12 -gramsOrdered: 05/30/19 Sampled:05/30/19
Completed: 06/06/19 Expires: 06/06/20Sampling Method: SOP Client Method
Residual solvent Action Level(ppm) Pass/Fail Results(ppm)Hexanes (2,3-dimethylbutane) 290 Pass ND1,4-Dioxane 380 Pass NDPentanes (iso-pentane) 5000 Pass NDPentanes (neo-pentane) 5000 Pass NDButanes (iso-butane) 5000 Pass ND2-Butanol 5000 Pass ND2-Ethoxyethanol 160 Pass ND2-Propanol 5000 Pass NDAcetone 5000 Pass NDAcetonitrile 410 Pass NDBenzene 1 Pass NDButanes (n-butane) 5000 Pass NDCyclohexane 3880 Pass NDDichloromethane 600 Pass NDHexanes (2,2-dimethylbutane) 290 Pass NDXylenes-O (1,2-dimethylbenzene) 2170 Pass NDXylenes-M (1,3-dimethylbenzene) 2170 Pass NDXylenes-P (1,4-dimethylbenzene) 2170 Pass NDEthanol 5000 Pass NDEthyl acetate 5000 Pass NDEthylbenzene 2170 Pass NDEthyl ether 5000 Pass NDEthylene Oxide 50 Pass NDHeptane 5000 Pass NDn-Hexane 290 Pass NDIsopropyl acetate 5000 Pass NDMethanol 3000 Pass NDHexanes (2-methylpentane) 290 Pass NDHexanes (3-methylpentane) 290 Pass NDPentanes (n-pentane) 5000 Pass NDPropane 5000 Pass NDTetrahydrofuran 720 Pass NDToluene 1068 Pass NDXylenes 2170 Pass ND
4131 SW 47th AVENUE SUITE1408DAVIE, FL [email protected] ___________________
Jorge SegredoLab Director
State License # n/aISO Accreditation #97164
This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or productanalyzed. Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error.IC=In-control QC parameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit OfQuantitation (LoQ) are terms used to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels areState determined thresholds for human safety for consumption and/or inhalation.
Certificate of Analysis1500MG FULL SPECTRUM TINCTUREN/AMatrix: N/A Page 6 of 7
Soothing Solutions8340 Lakewood Ranch Blvd.BradentonFlorida, United States [email protected]
SAMPLE:DA90604009-006METRC/Biotrack#4 Harvest/Lot ID: 1
Batch#: 1, Sample Size: 12 -gramsOrdered: 05/30/19 Sampled:05/30/19
Completed: 06/06/19 Expires: 06/06/20Sampling Method: SOP Client Method
Cannabinoid Profile Test Result-Analysis Method :SOP.T.40.020, SOP.T.30.050 Analytical Batch:DA003758Reagent LOT ID Dilution Consumables Id060419.R26 10 180711060419.R25 SFN-BX-1025060419.R14 849C4-849AK
840C6-840HFull spectrum cannabinoid analysis utilizing High Performance Liquid Chromatography with UV detection (HPLC-UV). (Method: SOP.T.30.050 for sample prep and Shimadzu HighSensitivity Method SOP.T.40.020 for analysis. LOQ for all cannabinoids is 1 mg/L).Filth and foreign Materials-Analysis Method :SOP.T.40.013This includes but is not limited to hair, insects, feces, packaging contaminants, and manufacturing waste and by-products. An SH-2B/T Stereo Microscope is use for inspection.
Mycotoxin Analysis-Analysis Method :SOP.T.30.065, SOP.T.40.065 Analytical Batch:DA003753Analyte Results Action LevelAflatoxin G2 ND 0.02Aflatoxin G1 ND 0.02Aflatoxin B2 ND 0.02Aflatoxin B1 ND 0.02Ochratoxin A+ ND 0.02Aflatoxins B1, B2, G1, G2, and Ochratoxins A testing using LC-MS. (Method: SOP.T.30.065 for Sample Preparation and SOP.T40.065 Procedure for Mycotoxins QuantificationUsing LCMS. LOQ 1.0 ppb). Total Aflatoxins (Aflotoxin B1, B2, G1, G2) must be <20µg/Kg. Ochratoxins must be <20µg/Kg.Micro Analysis-Analysis method :SOP.T.40.043 Analytical Batch: DA003755Pathogens ResultsAspergillus_terreus_1J2 not present in 1 gram.Aspergillus_niger not present in 1 gram.Aspergillus_fumigatus not present in 1 gram.Aspergillus_flavus not present in 1 gram.Salmonella_specific_gene not present in 1 gram.Escherichia_coli_Shigella_spp_ not present in 1 gram.Microbiological testing for Fungal and Bacterial Identification via Polymerase Chain Reaction (PCR) method consisting of sample DNA amplified via tandem Polymerase ChainReaction (PCR) as a crude lysate which avoids purification. (Method SOP.T.40.043) If a pathogenic Escherichia Coli, Salmonella, Aspergillus fumigatus, Aspergillus flavus,Aspergillus niger, or Aspergillus terreus is detected in 1g of a sample, the sample fails the microbiological-impurity testing.
4131 SW 47th AVENUE SUITE1408DAVIE, FL [email protected] ___________________
Jorge SegredoLab Director
State License # n/aISO Accreditation #97164
This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or productanalyzed. Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error.IC=In-control QC parameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit OfQuantitation (LoQ) are terms used to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels areState determined thresholds for human safety for consumption and/or inhalation.
Certificate of Analysis1500MG FULL SPECTRUM TINCTUREN/AMatrix: N/A Page 7 of 7
Soothing Solutions8340 Lakewood Ranch Blvd.BradentonFlorida, United States [email protected]
SAMPLE:DA90604009-006METRC/Biotrack#4 Harvest/Lot ID: 1
Batch#: 1, Sample Size: 12 -gramsOrdered: 05/30/19 Sampled:05/30/19
Completed: 06/06/19 Expires: 06/06/20Sampling Method: SOP Client Method
Pesticide Analysis-Analysis Method:SOP.T.30.065, SOP.T.40.065 Analytical Batch :DA003752Reagent LOT/ID Dilution Consumables ID060419.R13 1 180711
280653964Pesticide screen is performed using LC-MS which can screen down to below single digit ppb concentrations for regulated Pesticides. Currently we analyze for 57 Pesticides.(Method: SOP.T.30.065 Sample Preparation for Pesticides Analysis via LCMSMS and SOP.T40.065 Procedure for Pesticide Quantification Using LCMS).Heavy Metals Analysis-Analysis-Method:SOP.T.40.050, SOP.T.30.052 Analytical Batch: DA003746Reagent LOT/ID Dilution Consumables ID
50Heavy Metals screening is performed using ICP-MS (Inductively Coupled Plasma – Mass Spectrometer) which can screen down to below single digit ppb concentrations forregulated heavy metals using Method SOP.T.30.052 Sample Preparation for Heavy Metals Analysis via ICP-MS and SOP.T.40.050 Heavy Metals Analysis via ICP-MS.Metal Result Action-LevelArsenic ND 1.500Cadmium ND 0.500Lead ND 0.500Mercury ND 3Abbreviation:ppm=Parts Per MillionResidual SolventsAnalysis Method:SOP.T.40.032 Analytical Batch :DA003749Residual solvents screening is performed using GC-MS which can detect below single digit ppm concentrations. Currently we analyze for 34 Residual solvents. (Method:SOP.T.30.042 Residual Solvents Analysis via GC-MS).Terpenes screening-Analysis-Method:SOP.T.40.090 Analytical Batch :DA003745Terpenoid profile screening is performed using GC-MS with Liquid Injection (Gas Chromatography – Mass Spectrometer) which can screen 38 terpenes using MethodSOP.T.40.091 Terpenoid Analysis Via GC-MS/MS.
4131 SW 47th AVENUE SUITE1408DAVIE, FL [email protected] ___________________
Jorge SegredoLab Director
State License # n/aISO Accreditation #97164
This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or productanalyzed. Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error.IC=In-control QC parameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit OfQuantitation (LoQ) are terms used to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels areState determined thresholds for human safety for consumption and/or inhalation.