certificate of analysis - clearly better days
TRANSCRIPT
Certificate of Analysis907T-5071-1 T900Harvest/Lot ID: # 907T-5071-1Batch#: 907T-5071-1
Page 1 of 5
Clearly Better Days, LLCPO Box 7025 LoudonNH, United States 03307(603) [email protected]
SAMPLE:DA90910007-002Sample is BELOW 0.3% THCRetail Product Size : 30 ml
Total Weight: 30 mlOrdered: 09/04/19 Sampled:09/04/19
Completed: 09/13/19 Expires: 09/13/20
Image Safety
Pesticides - PassedMicrobials - PassedMycotoxins - PassedHeavy Metals - PassedTerpenes - NOT TestedResidual-Solvents - PassedFilth - PassedWater Activity - NOT TestedMoisture - NOT Tested
Cannabinoids
0.00%Total THC
3.439%Total CBD
0.00 mgTHC/Container
1,031.70 mgCBD/Container
CannabinoidsAnalyte Weight(%) mg/gD9-THC ND ND
THCA ND ND
CBD 3.439 34.390
CBDA ND ND
CBN ND ND
CBDV 0.033 0.330
D8-THC ND ND
THCV ND ND
CBG 0.096 0.960
CBGA ND ND
CBC ND ND
TOTAL THC ND ND
TOTAL CBD 3.439 34.390
ND ND
3.439
ND ND 0.033 ND ND 0.096 ND ND ND
3.439
D9-THC THCa CBD CBDa CBN CBDV D8-THC THCV CBG CBGa CBC Total THC Total CBD
4131 SW 47th AVENUE SUITE1408DAVIE, FL [email protected] ___________________
Jorge SegredoLab Director
State License # n/aISO Accreditation #97164
This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or product analyzed.Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error. IC=In-control QCparameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit Of Quantitation (LoQ) are termsused to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels are State determined thresholds forhuman safety for consumption and/or inhalation.
Certificate of Analysis907T-5071-1 T900Harvest/Lot ID: # 907T-5071-1Batch#: 907T-5071-1
Page 2 of 5
Clearly Better Days, LLCPO Box 7025 LoudonNH, United States 03307(603) [email protected]
SAMPLE:DA90910007-002Sample is BELOW 0.3% THCRetail Product Size : 30 ml
Total Weight: 30 mlOrdered: 09/04/19 Sampled:09/04/19
Completed: 09/13/19 Expires: 09/13/20
Pesticides LOQ Action Level Units ResultDIMETHOATE 0.01 0.05 ppm NDABAMECTIN B1A 0.02 0.1 ppm NDPENTACHLORONITROBENZENE 0.01 0.2 ppm NDMETHYL PARATHION 0.05 0.2 ppm NDCYFLUTHRIN 0.05 1 ppm NDCIS-PERMETHRIN 0.05 0.1 ppm NDACEPHATE 0.01 0.1 ppm NDDIMETHOMORPH 0.005 0.05 ppm NDETHOPROPHOS 0.01 0.05 ppm NDACEQUINOCYL 0.05 0.1 ppm NDACETAMIPRID 0.01 0.05 ppm NDETOFENPROX 0.01 0.05 ppm NDALDICARB 0.02 0.05 ppm NDETOXAZOLE 0.01 0.05 ppm NDAZOXYSTROBIN 0.01 0.05 ppm NDFENHEXAMID 0.01 0.1 ppm NDBIFENAZATE 0.01 0.1 ppm NDFENOXYCARB 0.01 0.05 ppm NDFENPYROXIMATE 0.01 0.5 ppm NDBIFENTHRIN 0.01 0.1 ppm NDCARBARYL 0.01 ppm NDFIPRONIL 0.02 0.05 ppm NDFLONICAMID 0.01 0.4 ppm NDCARBOFURAN 0.01 ppm NDCHLORANTRANILIPROLE 0.01 ppm NDFLUDIOXONIL 0.01 0.1 ppm NDHEXYTHIAZOX 0.01 0.25 ppm NDCHLORFENAPYR 0.01 0.05 ppm NDIMAZALIL 0.01 0.05 ppm NDCHLORPYRIFOS 0.01 0.1 ppm NDIMIDACLOPRID 0.01 0.1 ppm NDCLOFENTEZINE 0.01 0.2 ppm NDKRESOXIM-METHYL 0.01 0.1 ppm ND
Pesticides LOQ ActionLevel
Units Result
COUMAPHOS 0.005 0.05 ppm NDMALATHION 0.01 0.05 ppm NDCYPERMETHRIN 0.02 0.5 ppm NDDAMINOZIDE 0.02 0.5 ppm NDMETALAXYL 0.01 0.05 ppm NDDICHLORVOS 0.05 0.1 ppm NDMETHIOCARB 0.01 0.05 ppm NDMETHOMYL 0.01 0.1 ppm NDDIAZANON 0.01 0.05 ppm NDMEVINPHOS 0.01 0.05 ppm NDMYCLOBUTANIL 0.01 0.1 ppm NDNALED 0.01 0.25 ppm NDOXAMYL 0.01 0.25 ppm NDPACLOBUTRAZOL 0.01 0.05 ppm NDTRANS-PERMETHRIN 0.05 0.1 ppm NDPHOSMET 0.01 0.1 ppm NDPIPERONYL BUTOXIDE 0.01 3 ppm NDPRALLETHRIN 0.05 0.1 ppm NDPROPICONAZOLE 0.01 0.1 ppm NDPROPOXUR 0.01 0.1 ppm NDPYRETHRIN I 0.01 0.5 ppm NDPYRIDABEN 0.01 0.2 ppm NDSPINOSAD (SPINOSYN A) 0.01 0.1 ppm NDSPINOSAD (SPINOSYN D) 0.01 0.1 ppm NDSPIROMESIFEN 0.01 0.1 ppm NDSPIROTETRAMAT 0.02 0.1 ppm NDSPIROXAMINE 0.01 0.05 ppm NDTEBUCONAZOLE 0.01 0.05 ppm NDTHIACLOPRID 0.01 0.05 ppm NDTHIAMETHOXAM 0.01 0.05 ppm NDTRIFLOXYSTROBIN 0.01 0.1 ppm ND
4131 SW 47th AVENUE SUITE1408DAVIE, FL [email protected] ___________________
Jorge SegredoLab Director
State License # n/aISO Accreditation #97164
This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or product analyzed.Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error. IC=In-control QCparameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit Of Quantitation (LoQ) are termsused to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels are State determined thresholds forhuman safety for consumption and/or inhalation.
Certificate of Analysis907T-5071-1 T900Harvest/Lot ID: # 907T-5071-1Batch#: 907T-5071-1
Page 3 of 5
Clearly Better Days, LLCPO Box 7025 LoudonNH, United States 03307(603) [email protected]
SAMPLE:DA90910007-002Sample is BELOW 0.3% THCRetail Product Size : 30 ml
Total Weight: 30 mlOrdered: 09/04/19 Sampled:09/04/19
Completed: 09/13/19 Expires: 09/13/20
Residual solvent Action Level(ppm) Pass/Fail Results(ppm)1,2-DICHLOROETHANE 2 Pass ND1,1-DICHLOROETHENE 8 Pass ND1,4-DIOXANE Pass ND2-BUTANOL Pass ND2-ETHOXYETHANOL Pass ND2-PROPANOL 500 Pass NDACETONE 750 Pass NDACETONITRILE 60 Pass NDBENZENE 1 Pass NDBUTANES (ISO-BUTANE) 2000 Pass NDBUTANES (N-BUTANE) 2000 Pass NDCHLOROFORM 2 Pass NDETHANOL 5000 Pass NDETHYL ACETATE 400 Pass NDCYCLOHEXANE Pass NDDICHLOROMETHANE Pass NDETHYL ETHER 500 Pass NDETHYLENE OXIDE 5 Pass NDETHYLBENZENE Pass NDHEPTANE 500 Pass NDHEXANES (2,2-DIMETHYLBUTANE) 60 Pass NDHEXANES (2,3-DIMETHYLBUTANE) 60 Pass NDHEXANES (2-METHYLPENTANE) 60 Pass NDHEXANES (3-METHYLPENTANE) 60 Pass NDISOPROPYL ACETATE Pass NDMETHALENE CHLORIDE 125 Pass NDMETHANOL 250 Pass NDN-HEXANE 60 Pass NDPENTANES (ISO-PENTANE) Pass NDPENTANES (N-PENTANE) 750 Pass NDPENTANES (NEO-PENTANE) Pass NDPROPANE 2100 Pass NDTETRAHYDROFURAN Pass NDTOLUENE 150 Pass NDTOTAL XYLENES 150 Pass NDTRICHLOROETHYLENE 25 Pass ND
4131 SW 47th AVENUE SUITE1408DAVIE, FL [email protected] ___________________
Jorge SegredoLab Director
State License # n/aISO Accreditation #97164
This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or product analyzed.Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error. IC=In-control QCparameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit Of Quantitation (LoQ) are termsused to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels are State determined thresholds forhuman safety for consumption and/or inhalation.
Certificate of Analysis907T-5071-1 T900Harvest/Lot ID: # 907T-5071-1Batch#: 907T-5071-1
Page 4 of 5
Clearly Better Days, LLCPO Box 7025 LoudonNH, United States 03307(603) [email protected]
SAMPLE:DA90910007-002Sample is BELOW 0.3% THCRetail Product Size : 30 ml
Total Weight: 30 mlOrdered: 09/04/19 Sampled:09/04/19
Completed: 09/13/19 Expires: 09/13/20
Cannabinoid Profile Test Result-Analysis Method :SOP.T.40.020, SOP.T.30.050 Analytical Batch:DA006207
Reagent LOT ID Dilution Consumables Id090619.R04 40 76124-662091019.R06 SFN-BX-1025
Reagent LOT ID Dilution Consumables Id090619.R03 923C4-923AK091019.R01 910C6 - 910H
Full spectrum cannabinoid analysis utilizing High Performance Liquid Chromatography with UV detection (HPLC-UV). (Method: SOP.T.30.050 for sample prep and Shimadzu High Sensitivity MethodSOP.T.40.020 for analysis. LOQ for all cannabinoids is 1 mg/L).Filth and foreign Materials-Analysis Method : Analytical Batch:DA006201
This includes but is not limited to hair, insects, feces, packaging contaminants, and manufacturing waste and by-products. An SH-2B/T Stereo Microscope is use for inspection.
Mycotoxin Analysis-Analysis Method :SOP.T.30.065, SOP.T.40.065 Analytical Batch:DA006217Analyte Results Action LevelAFLATOXIN_G2 ND 0.02AFLATOXIN_G1 ND 0.02AFLATOXIN_B2 ND 0.02AFLATOXIN_B1 ND 0.02OCHRATOXIN_A ND 0.02Aflatoxins B1, B2, G1, G2, and Ochratoxins A testing using LC-MS. (Method: SOP.T.30.065 for Sample Preparation and SOP.T40.065 Procedure for Mycotoxins Quantification Using LCMS. LOQ 1.0 ppb). TotalAflatoxins (Aflotoxin B1, B2, G1, G2) must be <20µg/Kg. Ochratoxins must be <20µg/Kg.
Micro Analysis-Analysis method :SOP.T.40.043 Analytical Batch: DA006204Reagent LOT/ID Dilution Consumables id090619.R02 A01
2803018013009A019009
Pathogens ResultsASPERGILLUS_TERREUS_1J2 not present in 1 gram.ASPERGILLUS_NIGER not present in 1 gram.ASPERGILLUS_FUMIGATUS not present in 1 gram.ASPERGILLUS_FLAVUS not present in 1 gram.SALMONELLA_SPECIFIC_GENE not present in 1 gram.ESCHERICHIA_COLI_SHIGELLA_SPP not present in 1 gram.Microbiological testing for Fungal and Bacterial Identification via Polymerase Chain Reaction (PCR) method consisting of sample DNA amplified via tandem Polymerase Chain Reaction (PCR) as a crude lysatewhich avoids purification. (Method SOP.T.40.043) If a pathogenic Escherichia Coli, Salmonella, Aspergillus fumigatus, Aspergillus flavus, Aspergillus niger, or Aspergillus terreus is detected in 1g of a sample,the sample fails the microbiological-impurity testing.
4131 SW 47th AVENUE SUITE1408DAVIE, FL [email protected] ___________________
Jorge SegredoLab Director
State License # n/aISO Accreditation #97164
This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or product analyzed.Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error. IC=In-control QCparameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit Of Quantitation (LoQ) are termsused to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels are State determined thresholds forhuman safety for consumption and/or inhalation.
Certificate of Analysis907T-5071-1 T900Harvest/Lot ID: # 907T-5071-1Batch#: 907T-5071-1
Page 5 of 5
Clearly Better Days, LLCPO Box 7025 LoudonNH, United States 03307(603) [email protected]
SAMPLE:DA90910007-002Sample is BELOW 0.3% THCRetail Product Size : 30 ml
Total Weight: 30 mlOrdered: 09/04/19 Sampled:09/04/19
Completed: 09/13/19 Expires: 09/13/20
Pesticide Analysis-Analysis Method:SOP.T.30.065, SOP.T.40.065 Analytical Batch :DA006216Reagent LOT/ID Dilution Consumables ID
10
Reagent LOT/ID Dilution Consumables ID
Pesticide screen is performed using LC-MS which can screen down to below single digit ppb concentrations for regulated Pesticides. Currently we analyze for 57 Pesticides. (Method: SOP.T.30.065 SamplePreparation for Pesticides Analysis via LCMSMS and SOP.T40.065 Procedure for Pesticide Quantification Using LCMS).Heavy Metals Analysis-Analysis-Method:SOP.T.40.050, SOP.T.30.052 Analytical Batch: DA006209Reagent LOT/ID Dilution Consumables ID
50
Reagent LOT/ID Dilution Consumables ID
Heavy Metals screening is performed using ICP-MS (Inductively Coupled Plasma – Mass Spectrometer) which can screen down to below single digit ppb concentrations for regulated heavy metals usingMethod SOP.T.30.052 Sample Preparation for Heavy Metals Analysis via ICP-MS and SOP.T.40.050 Heavy Metals Analysis via ICP-MS.Metal Result Action-LevelARSENIC ND 0.2CADMIUM ND 0.2LEAD ND 0.5MERCURY ND 0.1
Abbreviation:ppm=Parts Per MillionResidual SolventsAnalysis Method:SOP.T.40.032 Analytical Batch :DA006228Reagent LOT ID Dilution Consumables Id
1 00276446160861-1
Reagent LOT ID Dilution Consumables Id24152438
Residual solvents screening is performed using GC-MS which can detect below single digit ppm concentrations. Currently we analyze for 34 Residual solvents. (Method: SOP.T.30.042 Residual SolventsAnalysis via GC-MS).
4131 SW 47th AVENUE SUITE1408DAVIE, FL [email protected] ___________________
Jorge SegredoLab Director
State License # n/aISO Accreditation #97164
This report shall not be reproduced, unless in its entirety, without written approval from EVIO Labs. This report is an EVIO Labs certification. The results relate only to the material or product analyzed.Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error. IC=In-control QCparameter, NC=Non-controlled QC parameter, ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Limit Of Quantitation (LoQ) are termsused to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels are State determined thresholds forhuman safety for consumption and/or inhalation.