cerebral embolic protection in thoracic aortic stent-grafting · gagandeep grover. i have the...
TRANSCRIPT
![Page 1: Cerebral Embolic Protection in Thoracic Aortic Stent-grafting · Gagandeep Grover. I have the following potential conflicts of interest to report: Consulting Employment in industry](https://reader034.vdocuments.site/reader034/viewer/2022052007/601c2f275ea8572cbd313b03/html5/thumbnails/1.jpg)
Cerebral Embolic Protection in
Thoracic Aortic Stent-grafting
Gagandeep Grover
Rudarakanchana N, Perera A, Hamady M
Richard Gibbs
Imperial College London
![Page 2: Cerebral Embolic Protection in Thoracic Aortic Stent-grafting · Gagandeep Grover. I have the following potential conflicts of interest to report: Consulting Employment in industry](https://reader034.vdocuments.site/reader034/viewer/2022052007/601c2f275ea8572cbd313b03/html5/thumbnails/2.jpg)
Disclosure
Speaker name:
Gagandeep Grover.
I have the following potential conflicts of interest to report:
Consulting
Employment in industry
Stockholder of a healthcare company
Owner of a healthcare company
Other(s)
I do not have any potential conflict of interest
![Page 3: Cerebral Embolic Protection in Thoracic Aortic Stent-grafting · Gagandeep Grover. I have the following potential conflicts of interest to report: Consulting Employment in industry](https://reader034.vdocuments.site/reader034/viewer/2022052007/601c2f275ea8572cbd313b03/html5/thumbnails/3.jpg)
‘Silent’ cerebral infarction and stroke in TEVAR
• 2-10% Stroke, SCI still remain a significant risk
• SCI ‘ silent brain injury’ detected on DW MRI – predictor of
stroke, dementia, depression and neurocognitive decline – Kobayashi et al, Stroke 1997; Vermeer et al, N Eng J Med 2003; Schmidt et al, J Am Geriatr Soc 200
• Cerebral embolisation – principle risk factor
![Page 4: Cerebral Embolic Protection in Thoracic Aortic Stent-grafting · Gagandeep Grover. I have the following potential conflicts of interest to report: Consulting Employment in industry](https://reader034.vdocuments.site/reader034/viewer/2022052007/601c2f275ea8572cbd313b03/html5/thumbnails/4.jpg)
SCI, stroke and neurocognitive decline St Mary’s experience…
• Silent cerebral infarction after TEVAR: a neuroimaging study – N=19, 63% SCI rate
– Kalhert et al, Ann Thorac Surg 2014
• Perera et al, prospective observational study:
– N=52, 81% cerebral infarction, 68% SCI rate, 13% overt stroke
![Page 5: Cerebral Embolic Protection in Thoracic Aortic Stent-grafting · Gagandeep Grover. I have the following potential conflicts of interest to report: Consulting Employment in industry](https://reader034.vdocuments.site/reader034/viewer/2022052007/601c2f275ea8572cbd313b03/html5/thumbnails/5.jpg)
Neuro-pyschometric testing demonstrates a worrying cognitive decline……
TEVAR N=52
Median age 69
TCD N=42
DW-MRI N=31
Neurocognitive assessment
N=17
100% HITS
68% SCI
88% Decline 6/7
domains age>69
Maximum HITS Stent deployment 62 (IQR 35-192) Contrast injection 62 (IQR 22-163)
Median infarct volume 164mm2
IQR (108.64-1328.30mm2)
• REY auditory verbal test, verbal
learning and memory • Trail A – visual search and motor • Trail B – mental flexibility &
switching • Grooved pegboard – fine motor
skills • COWA – executive function
![Page 6: Cerebral Embolic Protection in Thoracic Aortic Stent-grafting · Gagandeep Grover. I have the following potential conflicts of interest to report: Consulting Employment in industry](https://reader034.vdocuments.site/reader034/viewer/2022052007/601c2f275ea8572cbd313b03/html5/thumbnails/6.jpg)
Sentinel Cerebral Embolic Protection System SPCS; Claret Medical, CA, USA
• Percuateous device through brachial
artery
• 6 Fr compatible sheath, 0.014 guide
wire
• 140υm diameter pore filters in
brachiocephalic and left common carotid
• Claretmedical.com
![Page 7: Cerebral Embolic Protection in Thoracic Aortic Stent-grafting · Gagandeep Grover. I have the following potential conflicts of interest to report: Consulting Employment in industry](https://reader034.vdocuments.site/reader034/viewer/2022052007/601c2f275ea8572cbd313b03/html5/thumbnails/7.jpg)
Experience of SPCS in TAVI
claretmedical.com
![Page 8: Cerebral Embolic Protection in Thoracic Aortic Stent-grafting · Gagandeep Grover. I have the following potential conflicts of interest to report: Consulting Employment in industry](https://reader034.vdocuments.site/reader034/viewer/2022052007/601c2f275ea8572cbd313b03/html5/thumbnails/8.jpg)
Cerebral Embolic Protection in TEVAR A Pilot Study
• SPCS successfully deployed and retrieved with all commercially available grafts: -c-Tag GORE, Medtronic, COOK, Bolton on pulsatile flow model testing N=8
• CEPD deployment & retrieval time(mins): 16 9 8 2
CTA grade of arch
Pathology
Proximal landing
zone
Post-op 3T DW-MRI (DAY2-5)
TCD HITS Neurocognitive assessment
Patient Age Gender No of
lesions
Volume of lesions mm2
Device manipulation
& deployment
Contrast CEPD
deployment and retrieval
Post-op 6 week follow
up
1 79 F 2 IMH 3 5 15.2 no bone windows for MCA signal no deterioration
2 46 M 2 Dissecti
on 2 0 nil 62 114 78 no deterioration
3 65 M 1 IMH 2 3 25.3 36 69 126 no deterioration
4 68 F 1 IMH 3 0 nil 76 25 9 no deterioration
![Page 9: Cerebral Embolic Protection in Thoracic Aortic Stent-grafting · Gagandeep Grover. I have the following potential conflicts of interest to report: Consulting Employment in industry](https://reader034.vdocuments.site/reader034/viewer/2022052007/601c2f275ea8572cbd313b03/html5/thumbnails/9.jpg)
MRI lesions FEMALE 1 MALE 2
25.3mm2 15.2mm2
![Page 10: Cerebral Embolic Protection in Thoracic Aortic Stent-grafting · Gagandeep Grover. I have the following potential conflicts of interest to report: Consulting Employment in industry](https://reader034.vdocuments.site/reader034/viewer/2022052007/601c2f275ea8572cbd313b03/html5/thumbnails/10.jpg)
Debris captured in 100% of filters
Tge
100% 100%
25%
0%
100%
0% 0% 0%
25%
50%
75%
100%
An
y d
ebri
s
Acu
te t
hro
mb
us*
Org
aniz
ing
thro
mb
us
Val
ve T
issu
e
Art
eria
l Wal
l
Cal
cifi
cati
on
Fore
ign
mat
eria
l
Debris captured in Proximal filters (n=4)
*Acute thrombus was always found in combination with other materials
100% 100%
75%
25%
75%
0%
75%
An
y d
ebri
s
Acu
te t
hro
mb
us*
Org
aniz
ing
thro
mb
us
Val
ve T
issu
e
Art
eria
l Wal
l
Cal
cifi
cati
on
Fore
ign
mat
eria
l
Debris captured in Distal filters (n=4)
Histopathology
![Page 11: Cerebral Embolic Protection in Thoracic Aortic Stent-grafting · Gagandeep Grover. I have the following potential conflicts of interest to report: Consulting Employment in industry](https://reader034.vdocuments.site/reader034/viewer/2022052007/601c2f275ea8572cbd313b03/html5/thumbnails/11.jpg)
Conclusion
• Encouraging results with initial experience with embolic protection device in TEVAR
• Further work needed in form of RCT to ascertain benefit
![Page 12: Cerebral Embolic Protection in Thoracic Aortic Stent-grafting · Gagandeep Grover. I have the following potential conflicts of interest to report: Consulting Employment in industry](https://reader034.vdocuments.site/reader034/viewer/2022052007/601c2f275ea8572cbd313b03/html5/thumbnails/12.jpg)
Acknowledgments
• Beccy Holmerg, Claret – technical support.
• CV Path – Santa Rosa, CA: histopathological analysis
![Page 13: Cerebral Embolic Protection in Thoracic Aortic Stent-grafting · Gagandeep Grover. I have the following potential conflicts of interest to report: Consulting Employment in industry](https://reader034.vdocuments.site/reader034/viewer/2022052007/601c2f275ea8572cbd313b03/html5/thumbnails/13.jpg)
Thank you
Any Questions?
![Page 14: Cerebral Embolic Protection in Thoracic Aortic Stent-grafting · Gagandeep Grover. I have the following potential conflicts of interest to report: Consulting Employment in industry](https://reader034.vdocuments.site/reader034/viewer/2022052007/601c2f275ea8572cbd313b03/html5/thumbnails/14.jpg)
Cerebral Embolic Protection in
Thoracic Aortic Stent-grafting
Gagandeep Grover
Rudarakanchana N, Perera A, Hamady M
Richard Gibbs
Imperial College London