City of Aurora Building Codes Division 15151 E Alameda Pkwy Aurora, CO 80012 (303) 739-7420

______________________________________________________

NoticeThis material is subject to copyright protection pursuant to Federal Law: 17 United States Code Section 106.

CINEMARK AURORA, COKEY PLAN1. 2. AUD. F AUD. E AUD. D AUD. G AUD. H AUD. XD AUD. J AUD. K AUD. L AUD. M AUD. C AUD. A AUD. B LOBBY AUD. P AUD. O AUD. N 3. 4.

Code violations that are found during inspection are required to be corrected. Permit issuance does not grant approval of a code violation. 2009 IBC 105.4

CONTRACTUALCONTRACTUAL DOCUMENTS ARE THE LATEST EDITION OF AIA A101 OWNER-CONTRACTOR AGREEMENT, AND AIA A201 GENERAL CONDITIONS OF CONTRACT FOR CONSTRUCTION. ALTERNATES WILL BE EXERCISED AT OPTION OF OWNER. G.C. TO COORDINATE RELATED WORK & MODIFY SURROUNDING WORK AS REQUIRED PAYMENTS - TEN (10) PERCENT RETAINAGE SHALL BE HELD UNTIL SUBSTANTIAL COMPLETION. MONTHLY PAYMENT REQUESTS SHALL BE ACCOMPANIED BY GUARANTEE AND PARTIAL LIEN WAIVERS FROM SUBCONTRACTORS AND MATERIAL SUPPLIERS. INSURANCE - CONTRACTOR AND SUBCONTRACTORS SHALL SECURE, PAY FOR, AND MAINTAIN THE FOLLOWING MINIMUM INSURANCE, WHICH SHALL BE ENDORSED TO INCLUDE THE OWNER AND ARCHITECT AS INSURED PARTIES & SHALL PROVIDE (30) THIRTY DAYS WRITTEN NOTICE OF ANY ALTERATION OR TERMINATION. CONTRACTOR SHALL NOT PROCEED WITH ANY WORK ON THE SITE UNTIL CERTIFICATES OF INSURANCE HAVE BEEN SUBMITTED AND ACCEPTED BY THE OWNER. WORKERS COMP COVERAGE A - BY GC AND ALL SUBCONTRACTORS STATUTORY LIMITS AS REQUIRED BY THE STATE OR AUTHORITY HAVING JURISDICTION WORKERS COMP COVERAGE B - BY GC AND ALL SUBCONTRACTORS $100K EACH ACCIDENT OR DISEASE $500K POLICY LIMIT COMMERCIAL GENERAL LIABILITY - BY GC $1MM COMBINED SINGLE LIMIT FOR PERSONAL INJURY AND PROPERTY DAMAGE $1MM EACH OCCURRENCE AND AGGREGATE LIMIT FOR PREMISISES, PRODUCT AND ADVERTISING LIABILITY, $1MM EACH OCCURRENCE AND AGGREGATE LIMIT FOR COMPLETED OPERATIONS AND PERSONAL INJURY LIABILITY $1MM AGGREGATE LIMIT PER PROJECT WHERE APPLICABLE $500K EACH OCCURRENCE AND AGGREGATE LIMIT FOR PERSONAL INJURY $500K EACH OCCURRENCE AND AGGREGATE LIMIT FOR PROPERTY DAMAGE AUTOMOBILE LIABILITY - BY GC AND ALL SUBCONTRACTORS $500K COMBINED SINGLE LIMIT FOR BODILY INJURY AND PROPERTY DAMAGE $250K EACH PERSON FOR PROPERTY DAMAGE $500K EACH OCCURRENCE FOR PROPERTY DAMAGE EXCESS LIABILITY - BY GC $5MM COMBINED SINGLE LIMIT FOR EACH OCCURRENCE AND AGGREGATE BUILDERS RISK - BY OWNER WARRANTY - CONTRACTOR SHALL WARRANTY WORK FOR A PERIOD OF ONE YEAR FROM DATE OF SUBSTANTIAL COMPLETION. PROJECT RECORD DOCUMENTS - CONTRACTOR WILL LEGIBLY MARK CONTRACT DRAWINGS INDICATING CHANGES MADE BY FIELD CHANGES OF DIMENSION OR DETAIL, SUPPLEMENTAL CHANGES AND DETAILS NOT INDICATED ON ORIGINAL DRAWINGS. AT COMPLETION OF PROJECT DELIVER DRAWINGS TO ARCHITECT.

a r c h i t e c t sINTERNATIONAL

TK

SPECIFICATIONSGEOFOAM 1. ALL GEOFOAM TO BE ENTIRELY ENCASED IN EITHER GYPSUM WALL BD OR CONCRETE. STEEL 1. FABRICATE STEEL IN ACCORDANCE WITH AISC MANUAL. 2. ALIGN AND ADJUST MEMBERS FORMING PARTS OF COMPLETE FRAME OR STRUCTURE AFTER ASSEMBLY BUY BEFORE FASTENING. ROUGH CARPENTRY 1. PROVIDE SUFFICIENT FIRE RETARDANT TREATED WOOD BLOCKING AT ALL STUDS FOR SECURING OF WALL & CEILING ITEMS, WHETHER FURNISHED BY OWNER OR CONTRACTOR. 2. CONCEALED WOOD IS TO BE FIRE RETARDANT TREATED UNLESS NOTED OTHERWISE. 3. PRESERVATIVE TREATED LUMBER IS REQUIRED FOR ALL ITEMS TO REMAIN IN CONTACT WITH CONCRETE OR MASONRY TO CONFORM TO AWPA STANDARD 5. 4. PLYWOOD SHALL BE CD GRADE APA FIR OR YELLOW PINE. 5. BLOCKING SHALL BE CLOSELY FITTED, ACCURATELY SET TO REQUIRED LINES & LEVELS, SECURELY CONNECTED & RIGIDLY FIXED IN PLACE, USING NAILS, SCREWS, &/OR BOLTS AS INDICATED OR REQUIRED BY GOOD PRACTICE. FINISH CARPENTRY 1. WOOD TRIM SHALL BE 'C' GRADE OR BETTER SOUTHERN YELLOW PINE OR CLEAR BIRCH, AWI CUSTOM GRADE FOR PAINTED FINISH. 2. INSTALL TRIM WORK STRAIGHT AND TRUE IN ALIGNMENT & RIGIDLY FASTEN IN PLACE. FIELD VERIFY ALL DIMENSIONS. COORDINATE WHERE BLOCKING OR BACKING IS REQUIRED. 3. MAKE ALL JOINTS TO CONCEAL SHRINKAGE, MITER ALL EXTERIOR CORNERS, COPE ALL INTERIOR CORNERS & SCARF ALL END-TO-END JOINTS. INSTALL PIECES AS LONG AS POSSIBLE TO MINIMIZE JOINTS. JOINTING ONLY WHERE SOLID SUPPORT IS OBTAINED. 4. DEEP SET ALL FASTENERS, FILL, CLEAN & SAND AS REQUIRED FOR PAINT OR STAIN FINISH. SEALANTS 1. ACCEPTABLE MANUFACTURERS ARE BOSTIK OR EQUAL & APPROVED. INSIDE AUDITORIUM SEALANT TO BE BLACK URETHANE BOSTIK 1100 FAST SET OR EQUAL. 2. ACRYLIC LATEX CAULK AT INTERIOR TRIM SHALL BE ASTM C834; PAINTABLE TYPE. 3. PROVIDE TWO (2) YEAR GUARANTEE TO OWNER ISSUED BY GENERAL CONTRACTOR & APPLICATOR. 4. PROVIDE PRIMERS, JOINT BACKING & OTHER ACCESSORIES AS REQUIRED, & RECOMMENDED BY THE MANUFACTURER. 5. PREPARE SURFACE PER SEALANT MANUFACTURER'S RECOMMENDATIONS, APPLY WITH SUFFICIENT PRESSURE TO FILL ALL VOIDS AND FINISH JOINTS TO BE SLIGHTLY CONVEX AND WEATHER TIGHT. 6. CAULK OR SEAL ALL JOINTS BETWEEN DISSIMILAR MATERIALS. 7. AUDITORIUM CONTROL JOINTS DOORS AND HARDWARE 1. GENERAL CONTRACTOR TO FIELD VERIFY ALL OPENING DIMENSIONS PRIOR TO ORDERING DOORS. 2. WORK IS TO MEET REQUIREMENTS OF HMMA GUIDE SPECIFICATION. 3. TEST AND ADJUST HARDWARE FOR QUIET, SMOOTH OPERATION, FREE OF STICKING, BINDING OR RATTLING. ADJUST CLOSER TO 5 LB. OPENING FORCE. GYPSUM WALL BOARD 1. PROVIDE & INSTALL METAL STUD WALL SYSTEMS IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS & THE GYPSUM CONSTRUCTION HANDBOOK AS PUBLISHED BY UGC. 2. METAL STUDS, DIETRICH OR EQUAL, 3 5/8". PER ASTM 525, G-90. 3. FURRING CHANNELS, 7/8" USG OR EQUAL. 4. FASTENERS SHALL BE USG BUGLE HEAD SCREWS. 5. JOINT TREATMENT SHALL BE: - PREFILLER-USG DURABOND 90 - TAPEUSG PERF-A-TAPE - FILLER-USG READY-MIXED JOINT COMPOUND 6. PAPER FACED METAL TRIM TO MEET ASTM C1047 - CORNER BEADS-USG BEADEX INSIDE AND OUTSIDE CORNERS - CASING BEADS-USG BEADEX L TRIMS 7. ALL EXTERIOR CORNERS SHALL RECEIVE CORNER BEADS, & EXPOSED EDGES (AT END OF NEW DRYWALL WORK)SHALL RECEIVE CASING BEADS TAPED IN WITH THE JOINT TREATMENT SYSTEM. 8. WALLS TO RECEIVE WALL COVERING SHALL BE BEDDED, TAPED & SANDED TO PROVIDE A SMOOTH, CONTINUOUS SURFACE & PRIMED AS RECOMMENDED BY WALL COVERING MANUFACTURER. 9. REVIEW ALL WORK AFTER PRIME COAT OF PAINT & CORRECT ANY VISIBLE JOINT OR FASTENER TREATMENT OR ROUGHNESS IN THE WORK. 10. FIRE TAPE INNER LAYERS OF GYPSUM BOARD AT RATED WALLS. FINISH TAPE & SAND OUTSIDE LAYER OF GYPSUM BOARD THAT WILL RECEIVE PAINT VINYL OR WALL CARPET. 11. ALL GYPSUM BOARD IS 5/8" (TYPE "X") UNLESS NOTED OTHERWISE (UNO). 12. MODIFICATIONS, NEW OPENINGS, PORT WINDOW REMOVAL, OR PORT RELOCATION SHALL MAINTAIN EXISTING SOUND WALL STANDARDS. INFILL EXISTING OPENINGS WITH SAME GAUGE AND SIZE STUDS - INFILL WITH 6" ACOUSTIC BATT INSULATION WITH TWO LAYERS 5/8" GYP. AUDITORIUM SIDE AND PROJECTION SIDE TO MATCH EXISTING. CUT BACK EXISTING FINISH GYP. LAYER ON AUDITORIUM SIDE AROUND OPENINGS TO ALLOW NEW FINISH GYP. STAGGER THE JOINTS OF GYP. LAYER BELOW BY 16" MINIMUM PROVIDE A CONTINUOUS BEAD OF ACOUSTICAL SEALANT AT PERIMETER OF EACH INSIDE LAYER OF GYPSUM BOARD EACH SIDE OF DEMISING WALL. BEAD SHOULD BE PLACED AS TO BE IN CONTACT WITH INSIDE EDGE OF BOARD, FLOOR TRACK AND FLOOR. FINAL OUTER LAYERS EACH SIDE OF DEMISING WALL REQUIRE TO BE TAPED AND FILLED TYP. - LISTED BELOW ARE TYP INNER LAYER GUIDELINES FOR JOINT FINISHING: - FACTORY EDGE TO FACTORY EDGE CONDITIONS DO NOT REQUIRE TO BE TAPED AND FILLED IN LAYERS BELOW FINISH LAYER. - ANY CUT EDGES OR CORNERS ON INNER LAYERS WILL REQUIRE TO BE TAPED AND FILLED TYP. - ANY GAPS OR BROKEN CORNERS, MUST BE TAPED TYP. SUBSTRATE FLOOR LEVELER 1. TRANSITIONS BETWEEN FLOOR FINISHES OF DIFFERENT THICKNESSES ARE TO UTILIZE 12" WIDE JOHNSONITE SUBFLOOR LEVELER SYSTEM UNDER THE THINNER MATERIAL. 2. ALL CORNERS ARE TO BE MITERED TO PROVIDE SMOOTH EVEN TRANSITIONS ALL THE WAY AROUND DIFFERENT MATERIALS. 3. SUBSTRATE SYSTEM TO BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS USING APPROVED ADHESIVE. TILE 1. TILE TO CONFORM TO MANUFACTURER'S RECOMMENDATIONS, TILE COUNCIL OF NORTH AMERICA AND NATIONAL TILE ASSOCIATION. 2. WALL TILE SUBSTRATE TO BE PER NATIONAL TILE ASSOCIATION RECOMMENDATION 3. PROVIDE TILE BASE AS NOTED IN THE DRAWINGS. 4. GROUT AT XD ENTRY TILE TO BE BLACK UNSANDED. 5. ALL CURVED TILE TO BE LASER CUT. 6. EXTERIOR RATED MOTAR AND GROUT TO BE USED ON ALL EXTERIOR TILE WORK. 7. FOR ANY TILE BIGGER THAN 12" ALONG ONE SIDE THIN SET MORTAR WITH MEDIUM BED CAPABILITIES IN RAPID SETTING FORMULATIONS IS TO BE USED. THE INSTALLER SHALL WAIT UNTIL THE MORTAR IS CURED BEFORE GROUTING. INSTALLER TO FOLLOW THE MANUFACTURER'S ALLOWABLE FLATNESS TOLERANCE. VINYL WALLCOVERING 1. ALL WALLS TO RECEIVE WALL VINYL ARE TO HAVE COLOR MATCHED SIZING. 2. PREPARE ALL WALLS TO RECEIVE NEW WALL COVERING. FILL HOLES, CRACKS AND DEPRESSIONS WITH PATCHING COMPOUND; SAND SMOOTH AND FLUSH. 3. REMOVE ANY LOOSE AND FOREIGN MATTER THAT COULD IMPAIR ADHESION. 4. APPLY SEALER AS RECOMMENDED BY THE WALL COVERING MANUFACTURER. 5. DO NOT LOCATE JOINTS WITHIN 6" OF CORNERS. 6. SMOOTH WALL COVERING TO ELIMINATE BUBBLES AND ENSURE ADHESION. ACOUSTICAL CEILINGS 1. MATCH EXISTING BUILDING STANDARDS 2. BLACK LAY-IN TO BE ARMSTRONG OMNI FISSURED 1729BL 2'X4' BLACK. GRID TO BE 15/16 EXPOSED, BLACK. ALL OTHER NEW CEILING TILE PER DRAWINGS AND SCHEDULE. 3. WHERE CEILING TILE IS BEING REPLACED PROTECT GRID DURING DEMOLITION. REPLACE ANY DAMAGED GRID AS REQUIRED PRIOR TO INSTALLING NEW CEILING TILES. PAINTING 1. GRILLS, DIFFUSERS, LIGHT TRIM RINGS, ACCESS PANELS, BATTERY PACK UNITS ETC ARE TO BE PAINTED TO MATCH SURROUNDING SURFACE/FINISH. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PATCHING OF ALL NAIL HOLES, CRACKS ETC., PRIOR TO FINAL PAINTING. 3. WORK INCLUDES PREPARATION OF SURFACES FOR PAINTING, FINISHING & THE APPLICATION OF PAINT & FINISH PRODUCTS ON ALL SURFACES WHICH ARE NOT FACTORY FINISHED. 4. ALL SURFACES MUST BE DRY, FREE FROM GREASE, OIL, MILDEW & GROUT; SANDED SMOOTH & FREE FROM LOOSE DIRT, DUST OR GRIT. 5. GLOSS SURFACES TO BE DULLED BY LIGHT SANDING. 6. ALL COATS TO BE TINTED TOWARDS FINAL COLOR, MINIMUM 3 COATS. GYPSUM BOARD PRIMERS TO BE FACTORY FORMULATED LATEX BASED FOR INTERIOR APPLICATION, SW PREPRITE 200, B28W200 SERIES OR EQUAL. 7. WOOD PRIMERS TO BE FACTORY FORMULATED ALKYD OR ACRYLIC BASED FOR INTERIOR APPLICATION, SW PREPRITE WOOD, B49W200 OR EQUAL FOR ACRYLIC ENAMEL & SEMIGLOSS FINISHES. 8. FERROUS METAL PRIMERS TO BE FACTORY FORMULATED QUICK DRYING RUST INHIBITIVE ALKYD BASED, SW KERN KROMIK UNIVERSAL METAL PRIMER, B50NZ6/B50WZ1 OR EQUAL. 9. GYPSUM BOARD CEILINGS & SOFFITS FINISH COAT TO BE FACTORY FORMULATED FLAT ACRYLIC LATEX, SW PROMAR 200 INTERIOR, B30W200 SERIES OR EQUAL. 10. GYPSUM BOARD WALLS FINISH COAT TO BE FACTORY FORMULATED SATIN ACRYLIC LATEX, SW B20W200 SERIES OR EQUAL. 11. WOOD & METAL SURFACES FINISH COAT TO BE FACTORY FORMULATED FULL GLOSS ALKYD ENAMEL, SW PROMAR 200 INTERIOR B35W200 SERIES OR EQUAL. 12. PROVIDE LEFT OVER STOCK OF 1 GALLON FOR EACH FINISH COLOR USED. 13. DO NOT PAINT EXISTING SPRINKLER COVERS. REPLACE WITH FACTORY PREFINISHED COVERS IF THE EXISTING COVERS ARE PAINTED. RESILIENT TILE AND BASE 1. STORE RESILIENT FLOORING MATERIAL IN SPACES WHERE THEY WILL BE INSTALLED FOR AT LEAST 48 HOURS BEFORE BEGINNING INSTALLATION 2. MAINTAIN MIN. TEMP. OF 65 F. IN SPACES TO RECEIVE RESILIENT FLOORING FOR AT LEAST 48 HOURS PRIOR TO INSTALLATION, DURING INSTALLATION AND FOR 48 HOURS AFTERWARDS. 3. MAINTAIN 55 F. ONCE WORK IS COMPLETED 4. DO NOT INSTALL RESILIENT FLOORING OVER CONCRETE SLAB UNTIL THEY HAVE BEEN CURED AND ARE SUFFICIENTLY DRY TO ACHIEVE BOND WITH ADHESIVE AS DETERMINED BY MANUFACTURER'S RECOMMENDED BOND AND MOISTURE TEST. 5. JOINTS OF RESILIENT FLOORING SHALL BE TIGHTLY BUTTED WITH NO GAPS. FLOORING WITH JOINTS WIDER THAN 1/32" SHALL BE REMOVED AND REPLACED 6. LAYOUT TILE SO THAT TILES ARE NOT LESS THAN HALF SIZE. 7. PLACE RESILIENT TILE WITH APPROVED ADHESIVE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 8. PROVIDE 10% BACK STOCK TO OWNER. 9. FRITZ FA88 ADHESIVE TO BE USED WITH RESILIENT TILE DUE TO SHORTENED SCHEDULE TO MAINTAIN FLOOR WARRANTY OVER RECENTLY REPLACED CONCRETE. 10. VINYL BASE INSIDE AND OUTSIDE CORNERS ARE TO BE PRE-FORMED FIRE EXTINGUISHERS 1. PROVIDE FIRE EXTINGUISHERS WITHIN TRAVEL DISTANCE OF 75 FEET DURING DEMOLITION AND ALTERATIONS. 2. IF F.E.C. IS WALL MOUNTED, RELOCATE TO NEW LOCATION AND REPAIR ALL WALLS DAMAGED BY WORKS TO MATCH ADJACENT. IF F.E.C. IS RECESSED, DO NOT DISTURB AND ADD NEW F.E.C. AS SHOWN. 3. GC SHALL VERIFY LOCATION AND NUMBER OF FIRE EXTINGUISHERS WITH FIRE INSPECTOR PRIOR TO INSTALLATION 4. NOTIFY ARCHITECT IMMEDIATELY IF ANY NEW AUDITORIUM WORK IMPACTS THE CURRENT LOCATION OF FIRE EXTINGUISHERS. CARPET 1. FILL EXSITING SUBFLOOR IF REQUIRED TO CREATE A SMOOTH SURFACE FOR CARPET INSTALLATION. 2. INSTALL PER MANUFACTURER'S RECOMMENDATIONS WITH MANFACTURER RECOMMENDED ADHESIVE. 3. PROTECT CARPET AFTER INSTALL BUT PRIOR TO OCCUPANCY WITH HEAVY DUTY KRAFT PAPER OR 0.006" THICK POLYETHYLENE FILM. 4. NO SEAMS WILL BE ALLOWED AT PEAK CIRCULATION AREAS. 5. PROVIDE EXTRA STOCK OF CARPET FOR EACH COLOR AND PATTERN PER CINEMARK PROJECT MANAGER. 6. LAY OUT AREAS TO RECEIVE CARPET TILES TO MINIMIZE TILES LESS THEN ONE HALF SIZE. 7. CUT CARPET TILE CLEAN. FIT TILES TIGHT TO INTERSECTION WITH VERTICAL SERFACES WITHOUT GAPS. WATER REPELLANT 1. PROTECT ALL SURFACES NOT REQUIRE CLEANING 2. APPLY EACO CHEM NMB-80 SURE KLEAN CUSTOM MASONRY CLEANER (OR APPROVED EQUAL) MASONRY CLEANER IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS 3. THOROUGHLY RINSE SURFACES WITH CLEAN WATER AFTER COMPLETION OF CLEANING; REMOVE ALL TRACES OF CLEANING SOLUTION. AFTER REMOVAL OF SCONCES ADDITIONAL CLEANING MAY BE REQUIRED. CONTACT ARCHTIECT IF NECESSARY 4. APPLY CHEM-TRETE BSM 40 VOC TO SURFACES NOTED ON ELEVATION SHEETS PER MANUFACTURER'S INSTRUCTIONS. WALL MURAL 1. WALL SURFACE MUST BE FREE OF GREASE, DUST AND LOOSE OR FLAKING MATERIAL TO ENSURE PROPER ADHESION OF THE SURFACE COATING. 2. PREP GYP. BD. TO A LEVEL 5 FINISH. 3. USE PRIMER AND ADHESIVE APPROVED BY MANUFACTURER AND OWNER. ESCUTCHEON, TYP.5'-0" MAX. (TYP.)

RAIL KEY2 1/2" MIN., 4 1/2" MAX.

5. 6. N

AURORA, CO #428 CINEMARK USA PERMIT SET 10.01.2012 TKA # 12057ALL WALL MOUNT RAIL ENDS TO RETURN TO WALL AT ENDS

106 West 11th Street Suite 1900 Kansas City, Missouri 64105 Phone : 816-842-7552 Fax : 816-842-1302DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT

12" TYP. 12" TYP. 1 1/2" O.D. PAINTED STEEL PIPE RAIL

2'-10" MIN.

SCREWS (3) FIRE RETARDANT TREATED 5/8" PLYWOOD BLOCKING CONCEALED BEHIND NEW PLAN LAYERS OF DRYWALL

VICINITY MAP GENERAL REQUIREMENTS1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. EXISTING THEATRE CONSTRUCTION IS UNCHANGED. PARKING FOR CONTRACTOR'S EMPLOYEES SHALL BE AS APPROVED BY OWNER. PHASING & OPERATIONS SHALL PERMIT CONTINUOUS OPERATION OF THE THEATRE. COORDINATE WITH OWNER. COORDINATE ACCEPTABLE HOURS OF NOISY WORK WITH THE OWNER. NOTIFICATION 48 HOURS IN ADVANCE MUST BE GIVEN FOR ANY WORK WHICH WILL AFFECT THEIR NORMAL OPERATION. THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR RECEIVING & PROTECTION AND SAFEKEEPING OF PRODUCTS STORED AT THE SITE, INCLUDING ALL OWNER FIXTURES & FITTINGS ETC. CONTRACTOR SHALL PROVIDE RECYCLING OR IF NON-RECYCLABLE DISPOSAL FOR PACKAGING ASSOCIATED WITH BUT NOT LIMITED TO OWNER FIXTURES AND FITTINGS. USE PREMISES FOR EXECUTION OF WORK AND FOR STORAGE AS DIRECTED BY THE OWNER. THE GENERAL CONTRACTOR SHALL POST AND MAINTAIN SIGNS, NOTICES AND OTHER SAFEGUARDS REQUIRED BY LAW OR ORDINANCE. ALL AUDITORIUMS UNDER RENOVATION TO BE ACCESSED THROUGH THE SCREEN SIDE EXIT DOORS ONLY. ENSURE CEILINGS DO NOT ENCROACH WITHIN 12" OF PROJECTION LINE. INFRARED LISTENING DEVICES ARE EITHER EXISTING TO BE MAINTAINED OR PROVIDED AND INSTALLED BY OWNER'S REPRESENTATIVE. GC SHALL MAKE PROVISIONS FOR BLOCKING AND INSTALLATION AS NOTED ON DRAWINGS, IF NOT EXISTING. OWNER VENDOR TO PROVIDE A PERMANENT PLACARD AT EACH AUDITORIUM WHERE WORK IS BEING DONE INDICATING OCCUPANT LOAD OF EACH AUDITORIUM. PLACARD TO BE PLACED IN CONSPICUOUS LOCATION IN EACH AUDITORIUM VESTIBULE. PROTECT HVAC SYSTEMS FROM CONSTRUCTION DEBRIS AND DUST. ANY HVAC NOT DISCONNECTED AND SEALED OFF DURING WORKS MUST HAVE ALL FILTRATION MEDIA REPLACED IMMEDIATELY PRIOR TO FINAL OCCUPANCY. MOVE PULL STATIONS AND STROBES AS NEEDED PER LOCAL JURISDICTION. EXISTING DIMENSIONS ARE BASED OFF PREVIOUS CONTRACT DOCUMENTS, GC TO FIELD VERIFY AND NOTIFY ARCHITECT OF DISCREPANCIES. GC TO ENSURE ALL LIGHTING IS WORKING PROPERLY. REPLACE OR REPAIR ANY LIGHTING AS REQUIRED.

SHEET INDEXARCHITECTURAL STRUCTURAL Sheet Number S1 S2 S3 Sheet Name AUD. XD STRUCTURAL PLANS & SECTION MISC. AUDITORIUM STRUCTURAL PLANS & DETAILS STRUCTURAL DETAILS Sheet Number A0.0 A0.01 A0.02 A0.10 A1.11 A1.21 A1.50 A1.51 A3.10 A3.60 Sheet Name COVER MATRIX OF RESPONSIBILITY EXISTING OVERALL PLANS (FOR REFERENCE ONLY) CODE PLAN OVERALL FIRST FLOOR PLAN OVERALL MEZZANINE PLAN ELEVATIONS - DEMO EXTERIOR ELEVATIONS - PROPOSED EXTERIOR ENLARGED PLANS & ELEVATIONS RESTROOMS & BOX OFFICE ENLARGED PLANS & ELEVATIONS AUDITORIUM A (AUD. P SIM) ENLARGED ELEVATIONS - AUDITORIUMS A &B ENLARGED PLANS & ELEVATIONS AUDITORIUM B (AUD. O SIM) ENLARGED PLANS & SECTIONS AUD. C (AUD. N SIM) ENLARGED ELEVATIONS - AUD. C & D ENLARGED PLANS & SECTIONS AUD. D (AUD. M SIM) ENLARGED PLANS & SECTIONS AUD. E (AUD. L SIM) ENLARGED PLANS & SECTIONS AUD. F (AUD. K SIM) ENLARGED PLANS & SECTIONS AUDITORIUM G (AUD. J SIM) ENLARGED ELEVATIONS - AUDITORIUMS G &H ENLARGED PLANS & SECTIONS AUD. H ENLARGED ELEVATIONS AND DETAILS - XD AUD. XD DETAILS TYPICAL (NON XD) AUD. DETAILS REFLECTED CEILING PLAN FIRST FLOOR EXISTING 'A' REFLECTED CEILING PLAN FIRST FLOOR EXISTING 'B' REFLECTED CEILING PLAN FIRST FLOOR PROPOSED 'A' REFLECTED CEILING PLAN FIRST FLOOR PROPOSED 'B' REFLECTED CEILING PLAN MEZZANINE EXISTING 'A' REFELCTED CEILING PLAN MEZZANINE PROPOSED 'A' PARTIAL FINISH PLAN - FIRST FLOOR 'A' PARTIAL FINISH PLAN - FIRST FLOOR 'B' PARTIAL FINISH PLAN - MEZZANINE PARTIAL FINISH PLAN - MEZZANINE 'B' ELEVATIONS & DETAILS - INTERIOR ELEVATIONS - INTERIOR ELEVATIONS & DETAILS - INTERIOR FINISH PLAN - LEGEND & SCHEDULE

R1

WALL RAIL

1/2" = 1'-0"

5'-0" MAX BETWEEN POSTS FIELD VERIFY

6" RAD TYP. 1 1/2" DIA. RAIL. 2'-2" IN FRONT OF SEATS

SECTION TYP.

C/L EQ

2'-2"

EQ.

EQ

MEP

MEP0.1 MEP0.2 M2.1 P2.1 E1.1 E1.2 E2.1 E2.2 E2.3 E2.4 E3.1 E3.2 E4.1A E4.1B E4.2 E5.1 E5.2

ELEC SYMBOLS AND NOTES MECH. & PLUMBING SYMBOLS & NOTES PARTIAL FLOOR PLANS MECH. XD & RESTROOM REMODEL PLAN LOWER LEVEL FLOOR PLAN DEMOLITION LOWER LEVEL FLOOR PLAN DEMOLITION LOWER LEVEL FLOOR PLAN LIGHTING LOWER LEVEL FLOOR PLAN LIGHTING EXTERIOR POWER AND LIGHTING LIGHT FIXTURE SCHEDULE AND CONTROLS LOWER LEVEL FLOOR PLAN POWER MEZZANINE & ENLARGED CONCESSIONS FLOOR PLAN LOWER LEVEL AISLE LIGHTING - PART A LOWER LEVEL AISLE LIGHTING - PART B AUDITORIUM FLOOR PLANS LIGHTING EXISTING ONE LINE DIAGRAM EXISTING ONE LINE DIAGRAM

5"

ESCUTCHEONS TYP, MATCH RAIL TYP. ELEVATION CORE DRILL & SET IN GROUT. FLATTEN DECK IF RQRD.

A3.61 SECTION A3.62 A3.63 A3.64 A3.65 A3.66 3 1/2" MIN. C L 3" RAD TYP. 1 1/2" DIA. RAIL. 1'-0" EQ. A3.67 A3.68 EQ. A3.69 C L CONDITION IF RAIL IS NOT ON RISER EDGE ESCUTCHEONS TYP, MATCH RAIL TYP. ELEVATION CORE DRILL & SET IN GROUT. FLATTEN DECK IF RQRD. (AT RAMPS, RAIL TO BE CONTINUOUS 34" HIGH MIN. ABOVE RAMPLINE) 1/2" = 1'-0" ANGLE TO MATCH RAKE OF RISERS OR SLOPE OF FLOOR 2'-10" MIN. A3.70 A3.72 A3.73 A3.74 A4.10 A4.11 A4.12 A4.13 A4.20 A4.22 A5.10 A5.11 A5.20 A5.21 A5.60 A5.61 A5.62 A6.00

R2ALTERNATE END OF RAIL CONFIGURATION ON RAMP

GUARDRAIL 1'-0"

1/2" = 1'-0" 5'-0" MAX BETWEEN POSTS FIELD VERIFY

PROJECT LOCATION

VICINITY MAP NO SCALE 1. 2.

DEMOLITION NOTESGENERAL CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION WORK AND COORDINATION OF SAME, INCLUDING GENERAL CONSTRUCTION, MECHANICAL, ELECTRICAL AND PLUMBING, UNLESS NOTED OTHERWISE. DEMOLITION WORK SHALL BE COORDINATED WITH ALL SUBCONTRACTORS TO INSURE UNINTERRUPTED PROGRESS OF NEW CONSTRUCTION WORK. ALL DEMOLITION, CUTTING AND PATCHING SHALL BE DONE TO MAINTAIN STRUCTURAL, ACOUSTICAL AND FIRE RATING INTEGRITY OF EXISTING STRUCTURE & IS TO PROVIDE A SMOOTH FINISHED APPEARANCE WHEN COMPLETED. PATCH AND REPAIR ALL AREAS OF EXISTING SURFACES AFFECTED BY DEMOLITION TO MATCH NEW CONSTRUCTION. PRIOR TO DEMOLITION COORDINATE WITH OWNER REPRESENTATIVE WHICH MATERIALS, EQUIPMENT AND OTHER ITEMS ARE TO BE PROVIDED TO THE OWNER. COORDINATE LOCAL JURISDICTION WASTE MANAGEMENT DIVERSION PRIOR TO BEGINNING DEMOLITION. DIVERSION RECEIPTS, QUANTITIES, AND FINAL LOCATIONS ARE THE RESPONSIBILITY OF THE GC. GC IS RESPONSIBLE FOR PROVIDING APPROPRIATE CONTAINERS FOR DIVERSION MATERIALS AND ENFORCING SUBCONTRACTOR COMPLIANCE. MATERIALS NOT PROVIDED TO THE OWNER OR FROM DEMOLITION ARE TO BE REMOVED IN ONE OF THE FOLLOWING THREE METHODS: RECYCLED/DIVERTED, SALVAGED OR HAULED TO THE APPROPRIATE DISPOSAL LOCATION. ANY DISPOSAL OF MATERIALS MUST BE IN A LEGAL MANNER. RECYCLING/DIVERTED OR SALVAGED SHALL BE PREFERRED METHODS. CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION OF TEMPORARY DUST & SOUND CONTROL BETWEEN DEMOLITION AREA AND OCCUPIED AREA. WHERE OCCURS, CAREFULLY REMOVE AND CAP OFF EXISTING AISLE LIGHTING AS REQUIRED BY WORKS. GENERAL CONTRACTOR TO INSTALL NEW AISLE LIGHTING TO OWNER REQUIREMENTS AND SPECIFICATIONS INCLUDING DESIGN. WHEELCHAIR LOCATIONS TO HAVE CONTRASTING COLOR LIGHTING FOR VISUAL INDICATION. PAINT ALL J. BOXES TO MATCH ADJACENT SURFACES AND LOCATE BEHIND SEATS WHERE POSSIBLE. NEVER LOCATE IN DEMISING WALLS (SPECIFIC LOCATIONS AND REQUIREMENTS TO BE CONFIRMED WITH OWNER'S REPRESENTATIVE. ANY SPEAKERS, LIGHTS, SEATS, ACCESSORIES AND ATTACHMENTS REMOVED FOR NEW WORK SHALL BE PROVIDED TO OWNER. ANY SEATS OR FIXTURES TO REMAIN SHALL EITHER BE REMOVED AND REINSTALLED FOR PROTECTION OR PROTECTED FROM DAMAGE AND REPLACED BY CONTRACTOR IF DAMAGED FROM WORK. ANY REMOVED ITEMS, EQUIPMENT OR SEATS PERMANENTLY ATTACHED TO FLOOR BY EITHER BOLTS, ANCHORS OR OTHER ATTACHMENT DEVICES IF NOT REMOVED WITH ITEM MUST BE GROUND FLUSH TO SURROUNDING CONCRETE FLOOR. ANY DAMAGE TO SURROUNDING FLOORING MATERIAL MUST BE REPAIRED OR REPLACED. TRITIUM EXIT SIGNS ARE REGULATED BY THE US NUCLEAR REGULATORY COMMISSION (US NRC). TRITIUM EXIT SIGNS MAY NOT BE REMOVED FROM THE FACILITY WITHOUT FOLLOWING US NRC REGULATIONS. CARE AND APPROPRIATE MEASURES SHOULD BE TAKEN TO PROTECT ALL TRITIUM EXIT SIGNS FROM DAMAGE. NOTIFY OWNER IF ANY TRITIUM EXIT SIGNS ARE IMPACTED BY DEMOLITION OR NEW WORK OR WOULD BE MADE EXTRANEOUS BY EITHER. IF REINSTALLING ANY TO NEW LOCATIONS, PROTECT AND MAINTAIN ALL ASSOCIATED TAGS AND LABELS. VERIFY INTERIOR AND EXTERIOR SUB-GRADE UTILITIES PRIOR TO SLAB DEMOLITION. SALVAGE ITEMS THAT CAN BE RE-USED IN OTHER LOCATIONS INCLUDING POSTER CASES AND METAL CEILING ELEMENT IN LOBBY. VERIFY ALL ITEMS WITH CINEMARK PROJECT MANAGER PRIOR TO ANY DEMOLITION.

FACE OF RISER

2'-10"

N

PROJECT DIRECTORYOWNERCINEMARK USA 3800 DALLAS PARKWAY PLANO, TX 75093 CONSTRUCTION MANAGER: CHRIS CLINE EMAIL: [email protected] CELL: 214.632.3358 DESIGNER: JENNIFER OLIVE EMAIL: [email protected] CELL: 972.665.1251

1 1/2"

THEATRE ARCHITECTTK ARCHITECTS, INC. 106 WEST 11TH STREET, SUITE 1900 KANSAS CITY, MO 64105 PHN: 816.842.7552 FAX: 816.842.1302 CONTACT: IAN WILSON EMAIL: [email protected]

3. 4. 5. 6. 7.

SECTION

R3

GUARDRAIL

8. 9.

3" RAD TYP. 1 1/2" DIA. RAIL. 5'-0" MAX. 3 1/2" MIN. FACE OF RISER SECTION AISLE RAIL C L CONDITION IF RAIL IS NOT ON RISER EDGE

PERMIT SET 10.01.2012Revision Schedule Rev Rev Rev # Date Description

MEP ENGINEERENVIRODESIGN, INC CONTACT: SAM PATTON 900 RR 620 SOUTH SUITE C101-301 AUSTIN, TX 78734 [email protected] PHN: 512.693.9015 CELL: 512.633.5396

STRUCTURAL DESIGNER10. TK ARCHITECTS, INC. 106 WEST 11TH STREET, SUITE 1900 KANSAS CITY, MO 64105 PHN: 816.842.7552 FAX: 816.842.1302 CONTACT: DAVID TAYLOR EMAIL: [email protected]

FACE OF RISER C L 2 1/2" MIN. ESCUTCHEONS TYP, MATCH RAIL TYP. CORE DRILL & SET IN GROUT. FLATTEN DECK IF REQD. ELEVATION

11. 12.

PROJECT ADDRESSCENTURY 16 14300 EAST ALAMEDA AVE AURORA, CO 80012 OFFICE: 303-363-0300 FAX: 303-283-3456

STRUCTURAL ENGINEER OF RECORDNEEDHAM & ASSOCIATES 15950 COLLEGE BLVD LENEXA, KS 66219 CONTACT: TODD HILL PHN: 913-385-5300 EMAIL: [email protected]

R3B

1/2" = 1'-0"

ALL MODIFICATIONS TO THE AUTOMATIC SPRINKLER AND FIRE ALARM AS PART OF THIS WORK WILL BE DEFERRED SUBMITTALS BY LICENSED CONTRACTORS

City of Aurora Building DivisionProject: CENTURY THEATERS AURORA Address: 14300 E. ALAMEDA AVE. Occupancy Group: A-1 Construction Type: III-1HR-SPK RSN: 683943 Permit: 12-626423

EXISTING FINISH TO BE SANDED DOWN AND REPAINTED BLACK 2'-10" MIN.

WALL KEY Wall Key

CODEEXISTING WORK BUILT UNDER THE FOLLOWING: BUILDING CODES: 1994 UNIFORM BUIDLING CODE

5'-0" MAX.

City of Aurora Building DivisionNEW WORK TO CONFORM TO THE FOLLOWING: BUILDING CODES: 2009 INTERNATIONAL BUILDING CODE

Reviewed for Code Compliance Approved as Noted: Richard LaCoste Date: Oct 05, 20122006 INTERNATIONAL CODES & 2008 NEC

FACE OF RISER SECTION

FACE OF RISER ESCUTCHEONS TYP, MATCH RAIL TYP. ELEVATION WALL INSULATION

6" METAL STUD HORIZONTAL BRACING AS REQUIRED. REFER TO STRUCTURAL DRAWINGS 1 LAYERS OF 5/8" GYPSUM BOARD EACH SIDE

SEATING CAPACITY EXISTING: SEATING CAPACITY PROPOSED: SEATING CAPACITY AUDITORIUMS EXISTING: SEATING CAPACITY AUDITORIUMS PROPOSED: OCCUPANCY TYPE: CONSTRUCTION TYPE: BUILDING AREA: MAXIMUM ALLOWABLE AREA/FLOOR: HEIGHT OF BUILDING: FIRE PROTECTION: MAIN EXIT: PLUMBING REQUIREMENTS:

3,348 SEATS INCLUDING 68 WHC SPACES 3,035 SEATS INCLUDING 73 WHC SPACES REFER TO SHEETS A3.60 TO A3.72 FOR INDIVIDUAL AUDITORIUMS REFER TO SHEETS A3.60 TO A3.72 FOR INDIVIDUAL AUDITORIUMS GROUP A2.1 & A3 ASSEMBLY (EXISTING UNCHANGED) TYPE III 1-HOUR, FULLY SPRINKLED (UNCHANGED) (UNCHANGED) (UNCHANGED) (UNCHANGED) (UNCHANGED) (UNCHANGED) (UNCHANGED)

R3CHANDRAIL NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. a. b. c. 12. a. b. 13. 14. 15. 16. 17. 18. 19.

EXISTING AISLE RAIL TO REMAIN 1/2" = 1'-0"

B B1 B2

6" STUD WALL SIM. TO B 3 5/8" RESTROOM, XD ENTRY AND INTERIOR BOX OFFICE STUD WALL SIM. TO B 3 5/8" OR 4", FIELD VERIFY WIDTH, NO INSULATION, TO MATCH EXISTING CROSSOVER AND VOMITORY WALLS

683943 RSN: XXXXXX Permit #: 12-626423 YYYY-ZZZZZZ-AA

PROJECT # 12057

Code violations that are found during inspection are required to be corrected. Permit issuance does not grant approval of a code violation. 2009 IBC 105.4

Provide U.L. Class 2A10BC minimum rating fire extinguishers at a maximum 50'-0" travel distance prior to the Certificate of Occupancy issuance 2009 IFC Table 906.3[1] and 2007 NFPA 10

SUPPLEMENTAL ISSUESCurrent Revision Current Revision Date Current Revision Description

A separate construction permit is required for installation of or modification to an automatic fireextinguishing system. Construction documents for fire protection systems shall be submitted for review and approval prior to system installation. Approval of documents is required prior to installation or request for inspection. 2009 IFC, Section 105.7.1.

ESCUTCHEON COVERS TO BE PROVIDED AT ALL SUPPORT LOCATIONS TYP & PAINT TO MATCH RAIL COLOR. ALL HANDRAIL AND GUARDRAIL VERTICAL SUPPORTS TO MEET REQUIREMENTS OF ALL APPLICABLE CODES. ALL CORNERS TO BE ROUNDED AND ENDS RETURNED EITHER TO THE WALL, POST OR FLOOR. AT NEW FLOOR MOUNTED/CORE DRILLED HANDRAILS REPAIR AND REPLACE ANY DAMAGE TO ADJACENT FLOOR FINISHES. HANDRAILS & GUARDRAILS TO EXTEND MIN. 12" BEYOND END OF RAMPS TOP BOTTOM. HANDRAILS & GUARDRAILS TO EXTEND 12" BEYOND TOP RISER OF STAIRS & MIN. ONE TREAD + 12" AT BOTTOM RISER ONE SIDE TYPICAL. RAILS AT NEW WALLS TO HAVE BLOCKING IN NEW WALL. WALLS WHERE DRYWALL IS BEING ADDED TO BE CONSIDERED NEW WALLS. EXISTING WALLS WHERE RAILS ARE BEING ADDED OR MODIFIED ARE TO USE EITHER TOGGLER SNAPTOGGLE HEAVY DUTY ANCHORS OR FLUSH MOUNTED BLOCKING ALIGNED TO THE GYP. IF BLOCKING IS USED, EDGES AND JOINTS TO BE MUDDED AND TAPED TO PROVIDE A SMOOTH SURFACE WITH SURROUNDING. IF EXISTING ARE CARDINAL GOLD VEINED POWDER COATED, NOTIFY ARCHITECT FOR DIRECTION ON REUSE. TOP OF HANDRAILS (R1, R3, AND R3B TO BE BETWEEN 34" MINIMUM AND 38" MAXIMUM TO TOP OF RAIL. HANDRAILS THAT MAY IMPACT SIGHTLINES ARE TO BE HELD TO 34". ADJACENT HANDRAILS TO BE SAME HEIGHT REGARDLESS OF IMPACT. ALL SCREWS INTO WOOD BLOCKING & WOOD BLOCKING INTO METAL STUDS TO HAVE #12 1-1/2" WOOD SCREWS. HANDRAILS & TOP RAILS OF GUARDS: UNIFORM LOAD OF 50LB/FT APPLIED IN ANY DIRECTION. CONCENTRATED LOAD OF 200 LBF APPLIED IN ANY DIRECTION. UNIFORM & CONCENTRATED LOADS NEED NOT BE ASSUMED TO ACT CONCURRENTLY. INFILL OF GUARDS: CONCENTRATED LOAD OF 50 LBF APPLIED HORIZONTALLY ON AN AREA OF 1 SQ. FT. INFILL LOAD & OTHER LOAD NEED NOT BE ASSUMED TO ACT CONCURRENTLY IF EXISTING AREA MATERIAL OTHER THAN PAINTED PIPE, NOTIFY ARCHITECT AND OWNER TO DETERMINE IF EXISTING RAILS, ACCESSORIES AND MOUNTINGS ARE TO BE PROVIDED TO THEATRE. AT POSTS, GROUT TO BE EVEN WITH SURROUNDING SURFACE AND HAVE POSITIVE SLOPE TO PIPE TO ENSURE DRAINAGE AWAY FROM PIPE BASE. VERTICAL POSTS TO BE 1/2" STANDARD PIPE ALL NEW HANDRAILS, TO BE CARDINAL GOLD VEINED POWDER COATED. INTERIOR PAINTED PIPE RAILS WILL NOT BE ALLOWED AS A SUBSTITUTION AND WILL BE REPLACED AT GENERAL CONTRACTORS EXPENSE. EXISTING WALL MOUNTED RAILS WHERE INDICATED TO REMAIN TO BE TEMPORARILY REMOVED AND POWDER COATED CARDINAL GOLD VEINED TO MATCH NEW RAILS. ALL AUDITORIUM RAILS TO BE GOLD VEIN POWDER COATED EXCEPT R3C. RAILS AT THE LOBBY STAIRS TO BE GRAY HAMMERTONE SEMI-GLOSS #T064-GR660. WHERE R2 AND R3B ARE COMBINED THEY SHOULD BE CONNECTED AND SHARE POSTS AS REQUIRED PER SPACING. G.C. TO SUBMIT HANDRAIL SHOP DRAWINGS TO ARCHITECT PRIOR TO FABRICATION.

Existing Wall 1 1/2" Air Gap 3 5/8" STUD

COVER

INSULATION 2 LAYERS OF 5/8" GYPSUM BOARD

C

Demising Wall

3 5/8" METAL STUD HORIZONTAL BRACING AS REQUIRED. REFER TO STRUCTURAL DRAWINGS 1 LAYERS OF 5/8" GYPSUM BOARD ONE SIDE

SHEET NUMBER

E

3 5/8" INTERIOR STUD WALL

General Partition Notes: 1. DO NOT SCALE DRAWINGS.

A0.0

Page 1 of 1

AURORA, CO CUSA #428

3 1/2" MIN.

4"

EQ.

Sheet Number

Sheet Name

a r c h i t e c t sINTERNATIONAL

TK

106 West 11th Street Suite 1900 Kansas City, Missouri 64105 Phone : 816-842-7552 Fax : 816-842-1302DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT

MATRIX OF RESPONSIBILITY FURNISHED & INSTALLED BY OWNER X (12) X (3) X X (3) X X X X X X X X (11) X (6) X (4) (7) X X X (3) X X X X X X X (3) X X X FURNISHED BY OWNER & INSTALLED BY GC FURNISHED & INSTALLED BY GC (1)

ITEM ADA UPGRADES TO SITE AISLE LIGHTING AUDITORIUM ENTRY DOORS AUDITORIUM ENTRY PIECES BANNER CLIPS BLACK KOROGUARD BLACK RUBBER BASE CEILING GRID CEILING TILE CENTIVA COVERED MILLWORK BOX DOOR LAMINATE DRAPERY DRAPERY TRIM & BLOCKING EXISTING SCREEN & FRAME EXTERIOR PAINT EXTERIOR SCONCES EXTERIOR SIGNAGE EXTERIOR WALL TILE FLOOR CARPET FLOOR, WALL, & BASE TILE FURNITURE HANDRAILS INTERIOR PAINT INTERIOR SIGNAGE JOHNSONITE FLOOR CARPET TRANSITION AT SCREEN PLATFORM JOHNSONITE SUBSTRATE LEVELER SYSTEM FOR TRANSITIONS FROM TILE TO CARPET LANDSCAPE UPDATES LIGHTING MILLWORK MURALS OCCUPANCY PLACARDS OUTWATER PLASTIC BLACK CORNER GUARDS PARKING LOT LIGHTING PORT WINDOWS POSTER CASES PROJECTION & SOUND EQUIPMENT RESTROOM PARTITIONS SCHLUTER TRIM SCONCE BLOCKING SCONCES SCREENS & SCREEN FRAME SEALANTS, GROUTS,ADHESIVES SEATS SPEAKER & SCONCE BLOCKING SPEAKER PLATFORMS AT SCREEN SPEAKERS SPECIAL INSPECTIONS STAINLESS STEEL CORNER GUARDS SURROUND SPEAKER BRACKETS TICKET KIOSK TOILET PAPER DISPENSERS VCT VINYL WALLCOVERING WALL CARPET WOOD TRIM

PERMIT SET 10.01.2012Revision Schedule Rev Rev Rev # Date Description

X (12) X X X X X X X X X (8) X X (5) X X X (7) X X X (9) X (7) X (2) X X

This sheet of drawings has not been reviewed for code compliance.

X X X X (3) X (10) X X X (11) X

683943 RSN: XXXXXX Permit #: 12-626423 YYYY-ZZZZZZ-AA

PROJECT # 12057

MATRIX OF RESPONSIBILITY

(1) Items not specifically listed here to be furnished and installed by GC. (2) GC to add speaker wire as needed for sidewall, behind screen and rear speakers. GC to add speaker wire as required to bring speakers up to 18 pair #12 twisted stranded behind screen. (3) Power and blocking by GC. (4) Demolition and removal of existing screen and screen frame by GC. (5) Wall Schluter Trim by Cinemark. (6) If required by new work. (7) XD Auditorium only (8) GC responsible for relocation of electrical or other items required by new XD port (9) GC responsible for coordination of aisle & concrete work adjacent to seats in conjunction with seating shop drawings (10) Blocking at metal stud walls (11) Demolition of existing by GC (12) Items by Cinemark. Not included in this package

SHEET NUMBER

A0.01

AURORA, CO CUSA #428

a r c h i t e c t sINTERNATIONAL

TK

106 West 11th Street Suite 1900 Kansas City, Missouri 64105 Phone : 816-842-7552 Fax : 816-842-1302DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT

PERMIT SET 10.01.2012Revision Schedule Rev Rev Rev # Date Description

City of Aurora Building Division

Reviewed for Code Compliance Approved as Noted: Richard LaCoste Date: Oct 08, 20122006 INTERNATIONAL CODES & 2008 NEC

683943 RSN: XXXXXX Permit #: 12-626423 YYYY-ZZZZZZ-AA

PROJECT # 12057

EXISTING OVERALL PLANS (FOR REFERENCE ONLY)SHEET NUMBER

EXISTING OVERALL PLANS (FOR REFERENCE ONLY) 1 N.T.S.

A0.02

AURORA, CO CUSA #428

LEGEND68 POPULATION EXITING 10.2" MINIMUM REQ'D EGRESS 34" CLR WIDTH PROVIDED EGRESS WIDTH PER OCC. PER TABLE 1005.1 FOR SPRINKLED BUILDING. 0.3" STAIRS .2" ELSE WHERE EGRESS PATH EXISTING 1 HOUR FIRE RATED PARTITION F.E.C. NOTE: G.C. TO MAINTAIN ALL EXISTING FIRE RATINGS EXISTING FIRE EXTINGUISHER AND CABINET TO REMAIN

Name AUDITORIUM A AUDITORIUM B AUDITORIUM C AUDITORIUM D AUDITORIUM E AUDITORIUM F AUDITORIUM G AUDITORIUM H AUDITORIUM J AUDITORIUM K AUDITORIUM L AUDITORIUM M AUDITORIUM N AUDITORIUM O AUDITORIUM P AUDITORIUM XD BOX OFFICE BREAK ROOM COMPUTER ROOM COUNT ROOM ELECT. ELECT. ELEV LOBBY GAMES JANITOR JANITOR MACHINE ROOM MEZZANINE OFFICE OFFICER ROOM PARTY ROOM PREP. ROOM PROJECTION PROJECTION SAFE ROOM STORAGE STORAGE STORAGE STORAGE STORAGE

Occupany Load Existing Occupancy 297 SEATS INCL 4 WHC 158 SEATS INCL 4 WHC 171 SEATS INCL 4 WHC 141 SEATS INCL 4 WHC 125 SEATS INCL 4 WHC 125 SEATS INCL 4 WHC 236 SEATS INCL 4 WHC 421 SEATS INCL 6 WHC 236 SEATS INCL 4 WHC 125 SEATS INCL 4 WHC 125 SEATS INCL 4 WHC 141 SEATS INCL 4 WHC 171 SEATS INCL 4 WHC 158 SEATS INCL 4 WHC 297 SEATS INCL 4 WHC 421 SEATS INCL 6 WHC 3 1 3 N/A 1 1 N/A 20 1 1 1 80 1 2 N/A 4 27 27 1 1 1 1 1 1

New Occupancy 291 SEATS INCL 5 WHC 155 SEATS INCL 5 WHC 163 SEATS INCL 5 WHC 132 SEATS INCL 5 WHC 115 SEATS INCL 5 WHC 114 SEATS INCL 5 WHC 209 SEATS INCL 5 WHC 381 SEATS INCL 6 WHC 207 SEATS INCL 5 WHC 114 SEATS INCL 5 WHC 115 SEATS INCL 5 WHC 132 SEATS INCL 5 WHC 163 SEATS INCL 5 WHC 155 SEATS INCL 5 WHC 291 SEATS INCL 5 WHC 354 SEATS INCL 6 WHC Unchanged Unchanged Unchanged 1 Unchanged Unchanged N/A Unchanged Unchanged Unchanged Unchanged Unchanged Unchanged Unchanged 10 Unchanged Unchanged Unchanged Unchanged Unchanged Unchanged Unchanged Unchanged Unchanged

a r c h i t e c t sINTERNATIONAL

TK

AUDITORIUM F A102

AUDITORIUM K B160 AUDITORIUM H A131 AUDITORIUM G A120 AUDITORIUM XD B143 AUDITORIUM J B146 AUDITORIUM L B163

106 West 11th Street Suite 1900 Kansas City, Missouri 64105 Phone : 816-842-7552 Fax : 816-842-1302DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT

AUDITORIUM E A105

AUDITORIUM D A108

AUDITORIUM M B167

AUDITORIUM C A112

40 8" (34")

40 8" (34")

TOTAL OCCUPANCY = 3,600

AUDITORIUM N B171

5'-3 1/2"

5'-3 1/2" MEZZANINE LOAD (UNCHANGED) = 54 OCCUPANTS 54+80+4 = 138

AUDITORIUM B A116 AUDITORIUM A A130

AUDITORIUM O B175 AUDITORIUM P B156

2

MEZZANINE CODE PLAN - PROPOSED 3/64" = 1'-0"

384 76.8 (136") 57 11.4" (34")

384 76.8 (136") 104 20.8" (34")

City of Aurora Building Division57 11.4" (34")

STORAGE A101

137 27.4" (34") ELECTRICAL ELECTRICAL 170 34" (34") 104 20.8" (34")

STORAGE B159

Reviewed for Code Compliance Approved as Noted: Richard LaCoste Date: Oct 05, 20122006 INTERNATIONAL CODES & 2008 NEC

PERMIT SET 10.01.2012Revision Schedule Rev Rev Rev # Date Description

AUDITORIUM F A102 114 SEATS INCL 5 WHC

57 11.4" (34") FEC

AUDITORIUM G A120 209 SEATS INCL 5 WHC200 3 66 58 57 384

AUDITORIUM H A131 381 SEATS INCL 6 WHC

AUDITORIUM XD B143 354 SEATS INCL 6 WHC

AUDITORIUM K B160 114 SEATS INCL 5 WHC57 11.4" (34") FEC

AUDITORIUM J B146 207 SEATS INCL 5 WHC200 3 66 58 57 384

683943 RSN: XXXXXX Permit #: 12-626423 YYYY-ZZZZZZ-AAAUDITORIUM L B163 115 SEATS INCL 5 WHC

AUDITORIUM E A105 115 SEATS INCL 5 WHC

JANITOR A10458 11.6" (34") FEC

JANITOR B16258 11.6" (34") FEC

57 11.4" (34")

FEC FEC 33 6.6 (34") FEC

FEC

FEC

FEC FEC FEC 33 6.6" (34")

57 11.4" (34")

AUDITORIUM D A108 132 SEATS INCL 5 WHC

ELECT. A119105 21" (68")

WOMENS A123171 34.2 (68") 4+171+100+145+105 = 525 145 29" (68")

MENS A124

PREP. ROOM A147 MACHINE ROOM A136125 131

MENS B149177 35.4" (68")

WOMENS B150

ELECT. B157105 21" (68") FEC

AUDITORIUM M B167 132 SEATS INCL 5 WHC

33 6.6" (34") 66 13.2" (34")

PARTY ROOM B209 FEC

33 6.6" (34") 66 13.2" (34") FEC

FEC 82 16.4" (68") FEC 200 3 82 77 5 367

145 29" FEC (68")

4+177+100+145+105 = 531

AUDITORIUM C A112 163 SEATS INCL 5 WHC

FEC OFFICER ROOM STORAGE A125 A128 FEC

100

100

OFFICE B152

FEC

STORAGE A11581 16.2" (34") FEC

77 15.4" (68")

SAFE ROOM B153 COMPUTER ROOM B154 FEC FEC 200 3 82 77 362

82 16.4" (68")

PROJECT # 12057

AUDITORIUM N B171 163 SEATS INCL 5 WHC

BREAK ROOM B17377 15.4" (68") FEC 81 16.2" (34")

CODE PLAN

AUDITORIUM B A116 155 SEATS INCL 5 WHC

LOBBY B140FEC 69 69 FEC

AUDITORIUM O B175 155 SEATS INCL 5 WHC

FEC 78 15.6" (34") 367 73.4" (136")

146 29.2" (34")

AUDITORIUM A A130 291 SEATS INCL 5 WHC

GAMES B141

BOX OFFICE B142

AUDITORIUM P B156 291 SEATS INCL 5 WHC

146 29.2" (34")

COUNT ROOM B207362 72.4" (136")

78 15.6" (34")

SHEET NUMBER

LOBBY STAIRS/MEZZANINE CONCESSIONS STARCADE TICKETS FROM CORRIDORS TOTAL LOAD

510 138 63 20 4 256 991

991 198.2" (340")

1

FIRST FLOOR CODE PLAN - PROPOSED 3/64" = 1'-0"

A0.10

AURORA, CO CUSA #428

a r c h i t e c t sINTERNATIONAL

TK

5

LOBBY VIEW TOWARDS XD

4

LOBBY VIEW TOWARDS GAME ROOM

3

LOBBY VIEW TOWARDS CONCESSION

2

LOBBY TOWARDS BOX OFFICE

106 West 11th Street Suite 1900 Kansas City, Missouri 64105 Phone : 816-842-7552 Fax : 816-842-1302DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT

GENERAL PLAN NOTES: 1. G.C. TO VERIFY SIDE WALL INSULATION INSIDE AUDITORIUMS IS AT MINIMUM 1.5 LB 1" THICK ROLLED INSULATION. IF NOT, NOTIFY ARCHITECT AND CINEMARK PROJECT MANAGER.

LEGEND

Provide emergency illumination equipment that complies with 2011 NEC 700.12 (F) or 2011 NEC 700.

Provide a tactile sign saying EXIT at each egress stairway, exit passageway or exit discharge 2009 IBC 1011.3 and 2003 ANSI A117.1

* = REQUIRED EXIT

2. G.C. TO VERIFY PROJECTION WALL INSULATION INSIDE AUDITORIUMS IS AT MINIMUM 1.5 LB 2" THICK ROLLED INSULATION. IF NOT, NOTIFY ARCHITECT AND CINEMARK PROJECT MANAGER.

NEW WALL 3D #/X#.##

EXISTING DOOR TO REMAIN

EXISTING ELEVATION TO REMAIN PROPOSED ELEVATION

SCREEN ACCESS DOOR. THIS IS NOT AN EXIT

3. IN ALL AUDITORIUMS PROVIDE FILTER ON ALL RETURN SYSTEMS TO MINIMIZE AIR BORNE PARTICULATES DURING DUST GENERATION. MAINTAIN A HIGH LEVEL OF CLEANLINESS TO PROTECT SCREENS. MATCH LINE

CALLOUT OF 3D VIEW

NEW DOOR

A1.51

*12 5 A3.67 10 RE: A3.67 FOR ENLARGED AUD. DWGS

2

*STORAGE B159RE: A3.67 FOR ENLARGED AUD. DWGS (SIM)

STORAGE A101ELECTRICAL ROOM ELECTRICAL ROOM 1 9

*AUDITORIUM XD B143 354 SEATS INCL 6 WHC

*

AUDITORIUM F A102 114 SEATS INCL 5 WHC

* *

*

A3.69 17

5

AUDITORIUM H A131 381 SEATS INCL 6 WHC

A3.69 4

2

*

C

* *

100' - 0" 100' - 0" C

4

A3.67 9

4 A3.68

AUDITORIUM G A120 209 SEATS INCL 5 WHC 100' - 0"

2

A3.69 1

C

RE: A3.71 FOR ENLARGED AUD. DWGS

100' - 6" 101' - 0"

AUDITORIUM J 100' - 0" B146 207 SEATS INCL 5 WHCRE: A3.66 FOR ENLARGED AUD. DWGS (SIM)

4

A3.66

9 RE: A3.66 FOR ENLARGED AUD. DWGS

5 RE: A3.68 FOR ENLARGED AUD. DWGS SLOPE

AUDITORIUM E A105 115 SEATS INCL 5 WHC

RE: A3.68 FOR ENLARGED AUD. DWGS (SIM) 103' - 3" 104' - 9" 104' - 9" 103' - 3" 103' - 3" 104' - 9" 103' - 3" 103' - 3" 104' - 9" 103' - 3" 104' - 9"

05 A3.66 10

*

104' - 9"

*

*

AUDITORIUM L B163 115 SEATS INCL 5 WHC

JANITOR A104

RE: A3.70 FOR ENLARGED AUD. DWGS

JANITOR B162

*

3 A3.64 4

B VOID

B

C

VOID

RE: A3.65 FOR ENLARGED AUD. DWGS (SIM)

*9'-9 1/2"

*10'-7" B1 B1 17'-6" B1 3 A3.10

*ELECT. B157

ELECT. A119RE: A3.65 FOR ENLARGED AUD. DWGS 103' - 3" 104' - 9" A5.61 20

AUDITORIUM D A108 132 SEATS INCL 5 WHC

WOMENS A123B1 B1 2 4 A5.61 3 8

*

MENS A124

B1

MENS B149B

*

WOMENS B150

3

B1 B 3'-0" E E E E

4'-5"

B1 E

AUDITORIUM M B167 132 SEATS INCL 5 WHC104' - 9" 103' - 3"

A1.51 SIM

PERMIT SET 10.01.2012

A1.51 3

*B1

4

A3.65

5

MACHINE ROOM A136

E 15

4

A5.62 2 VOID

*

*

1 A3.64 2 E E

PROMENADE A129 PARTY ROOM B209

A5.61 6

7 A5.62 6 1 A3.10 PODIUM LOCATION2 /A 1.1 1

PREP. ROOM A147

PODIUM LOCATION

2 A3.10

100' - 0"

A5.61 10

*

Revision Schedule Rev Rev Rev # Date Description 1 10-08-12 Delta 1

3/A1 .

11

SAFE ROOM B153 OFFICE B152

RE: A3.63 FOR ENLARGED AUD. DWGS (SIM)

*

1

OFFICER ROOM A125

STORAGE A128

*COMPUTER ROOM B154 AUDITORIUM N B171 163 SEATS INCL 5 WHC

AUDITORIUM C A112 163 SEATS INCL 5 WHC

RE: A3.63 FOR ENLARGED AUD. DWGS 103' - 3" 104' - 9"

*ADA

*104' - 9" 103' - 3"

4

A3.63 5

STORAGE A115

104' - 9" 103' - 3"

104' - 9" 103' - 3"

BREAK ROOM B173

*VOID 12 9 A3.62 5 A3.62

100' - 0" VOID

*

6'-6"

RE: A3.60 FOR ENLARGED AUD. DWGS (SIM) SLOPE NEW TABLE TOP ON EXISTING BASE, TYP.

* *

LOBBY B1404 A5.60 2 PODIUM LOCATION

SLOPE

RE: A3.62 FOR ENLARGED AUD. DWGS (SIM.)

PROJECT # 12057

*AUDITORIUM O B175 155 SEATS INCL 5 WHC

*VOID

AUDITORIUM B A116 155 SEATS INCL 5 WHC

RE: A3.62 FOR ENLARGED AUD. DWGS VOID RE: A3.60 FOR ENLARGED AUD. DWGS 5 8

A5.60

103' - 3"

104' - 9"

104' - 9"

7 A3.61 4

*1

100' - 0" A3.60 A3.61 2

A5.60 9 A5.62

6

100' - 0"

*AUDITORIUM P B156 291 SEATS INCL 5 WHC

AUDITORIUM A A130 291 SEATS INCL 5 WHC

4

BOX OFFICE B142100' - 0"3D 4/A 1.1 13D

*

GAMES B141

B1

* *3 /A 1 1.1

B1

COUNT ROOM B207B A1.51 4

103' - 3"

OVERALL FIRST FLOOR PLAN

5

A1.51 A1.50 B

City of Aurora Building Division

Reviewed for Code Compliance Approved as Noted: Richard LaCoste Date: Oct 10, 20122006 INTERNATIONAL CODES & 2008 NEC

683943 RSN: XXXXXX Permit #: 12-626423 YYYY-ZZZZZZ-AA

SHEET NUMBER

1 A1.51 12 A3.10

FIRST FLOOR - PROPOSED 1 3/32" = 1'-0"N

A1.11

AURORA, CO CUSA #428

4

A3.72 3 104' - 9" 103' - 3"

103' - 3"

104' - 9"

SLOPE

AUDITORIUM K B160 114 SEATS INCL 5 WHC

3D

3D

LEGEND

NEW WALL 3D #/X#.##

EXISTING DOOR TO REMAIN

EXISTING ELEVATION TO REMAIN PROPOSED ELEVATION

CALLOUT OF 3D VIEW

NEW DOOR

GENERAL PLAN NOTES: 1. G.C. TO VERIFY SIDE WALL INSULATION INSIDE AUDITORIUMS IS AT MINIMUM 1.5 LB 1" THICK ROLLED INSULATION. IF NOT, NOTIFY ARCHITECT AND CINEMARK PROJECT MANAGER. 2. G.C. TO VERIFY PROJECTION WALL INSULATION INSIDE AUDITORIUMS IS AT MINIMUM 1.5 LB 2" THICK ROLLED INSULATION. IF NOT, NOTIFY ARCHITECT AND CINEMARK PROJECT MANAGER.

a r c h i t e c t sINTERNATIONAL

City of Aurora Building Division

Reviewed for Code Compliance Approved as Noted: Richard LaCoste Date: Oct 05, 20122006 INTERNATIONAL CODES & 2008 NEC

3. IN ALL AUDITORIUMS PROVIDE FILTER ON ALL RETURN SYSTEMS TO MINIMIZE AIR BORNE PARTICULATES DURING DUST GENERATION. MAINTAIN A HIGH LEVEL OF CLEANLINESS TO PROTECT SCREENS.

TK

106 West 11th Street Suite 1900 Kansas City, Missouri 64105 Phone : 816-842-7552 Fax : 816-842-1302DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT

683943 RSN: XXXXXX Permit #: 12-626423 YYYY-ZZZZZZ-AA

6 1/4"

53'-3 1/2"

6 1/4"

AUDITORIUM K B160 114 SEATS INCL 5 WHC AUDITORIUM F A102 114 SEATS INCL 5 WHCC 101' - 3" 103' - 3" 104' - 9" 106' - 3" 107' - 9" 109' - 3" 110' - 9"

101' - 7"

AUDITORIUM G A120 209 SEATS INCL 5 WHC

100' - 0"

100' - 0" 100' - 6" 101' - 0" 101' - 6"

21

C C

AUDITORIUM J 100' - 0" B146 207 SEATS INCL 5 WHC

101' - 3"

AUDITORIUM H A131 381 SEATS INCL 6 WHC

102' - 10" 100' - 0"

C

AUDITORIUM E A105 115 SEATS INCL 5 WHC101' - 3" 101' - 3" 103' - 3" 104' - 9" 106' - 3" 107' - 9" 109' - 3" 110' - 9"

101' - 3"

101' - 6"

13

101' - 6"

AUDITORIUM L B163 115 SEATS INCL 5 WHC

101' - 11 1/2" 110' - 9" 109' - 3" 107' - 9" 106' - 3" 104' - 9" 103' - 3" 18 104' - 9" 106' - 3" 107' - 9" 109' - 3" 110' - 9" 112' - 3" 113' - 9" 115' - 3" 116' - 9" 118' - 3" 22 112' - 3" 110' - 9" 109' - 3" 107' - 9" 106' - 3" 104' - 9" 12 15 120' - 0" 118' - 3" 124' - 6" 124' - 6" 118' - 3" 22 24 103' - 3" 104' - 9" 106' - 3" 107' - 9" 109' - 3" 110' - 9" 112' - 3" 113' - 9" 114' - 8" 103' - 3"

103' - 3" 104' - 9" 106' - 3" 107' - 9" 109' - 3" 110' - 9"

101' - 7"

106' - 3" 107' - 9" 109' - 3" 110' - 9" 112' - 3" 113' - 9" 115' - 3" 116' - 9"

101' - 3"

104' - 9"

AUDITORIUM D A108 132 SEATS INCL 5 WHC

112' - 3" 113' - 9"

AUDITORIUM M B167 132 SEATS INCL 5 WHC

114' - 8" 101' - 3" 103' - 3" 104' - 9" 106' - 3" 107' - 9" 109' - 3" 110' - 9" 112' - 3"

PERMIT SETPROJECTION B206117' - 4" 103' - 3"

PROJECTION A202117' - 4" 120' - 0"

119' - 9" 118' - 3" 121' - 3" 118' - 3"

119' - 9" 121' - 3"

101' - 7"

10.01.2012Revision Schedule Rev Rev Rev # Date DescriptionAUDITORIUM N B171 163 SEATS INCL 5 WHC

ELEV LOBBY A203

STORAGE B205116' - 9" 115' - 3"

116' - 9" 115' - 3"

AUDITORIUM C A112 163 SEATS INCL 5 WHC

113' - 9" 112' - 3" 110' - 9" 109' - 3"

118' - 3"

MEZZANINE B203

113' - 9" 112' - 3" 110' - 9" 109' - 3" 115' - 3" 113' - 9" 112' - 3" 110' - 9" 109' - 3" 107' - 9" 106' - 3" 104' - 9" 107' - 9" 106' - 3" 104' - 9" 103' - 3" 101' - 3" 103' - 3"

101' - 3"

103' - 3"

104' - 9"

106' - 3"

107' - 9"

109' - 3"

110' - 9"

112' - 3"

113' - 9"

101' - 7"

115' - 3"

107' - 9" 106' - 3" 104' - 9" 103' - 3"

101' - 3"

101' - 3"

101' - 3"

PROJECT # 12057AUDITORIUM B A116 155 SEATS INCL 5 WHC101' - 3" 103' - 3" 104' - 9" 106' - 3" 107' - 9" 109' - 3" 110' - 9" 112' - 3" 113' - 9"

OPEN TO BELOW

113' - 9"

112' - 3"

110' - 9"

109' - 3"

107' - 9"

106' - 3"

104' - 9"

100' - 0"

100' - 0"

AUDITORIUM A A130 291 SEATS INCL 5 WHC

101' - 7"

AUDITORIUM P B156 291 SEATS INCL 5 WHC101' - 7"

103' - 3"

AUDITORIUM O B175 155 SEATS INCL 5 WHC

OVERALL MEZZANINE PLAN

SHEET NUMBER

OVERALL MEZZANINE - PROPOSED 1 3/32" = 1'-0"N

A1.21

AURORA, CO CUSA #428

110' - 9"

109' - 3"

107' - 9"

106' - 3"

104' - 9"

103' - 3"

AUDITORIUM XD B143 354 SEATS INCL 6 WHC

4'-3"

Keynote Legend - DEMO A S ZH ZK MAINTAIN EXISTING DOOR. REMOVE EXISTING WALL FINISHES IN PREPARATION FOR NEW FINISHES. EXTERIOR EXISTING SIGNAGE TO REMAIN DEMOLISH EXISTING WALL SCONCES AND TEMPORARILY CAP POWER AS REQUIRED AND PREP WALL FOR NEW SCONCE. RE: MEP ZL DEMOLISH EXISTING NEON BANDS AND '16' SIGNAGE. CAP POWER AS REQUIRED AND PATCH EIFS TO LIKE NEW CONDITIONS ZM DEMOLISH PORTION OF WALL TO ALLOW FOR NEW SCREEN ACCESS DOOR. ZU EXISTING STOREFRONT GLAZING AND TILE COUNTER BUILD OUT. PREPARE TO INFILL WALL PER NEW WORKS. ZV PREPARE FOR NEW FINISHES. ZZG EXISTING CENTURY SIGNAGE TO BE DEMOLISHED. PATCH HOLES AS REQUIRED TO MATCH EXISTING ZZH DEMOLISH EXISTING POSTER CASES AND CAP POWER AS REQUIRED. PREP WALL FOR NEW LARGE POSTER CASES.

ZZG

ZL

TYP.

ZL

a r c h i t e c t sINTERNATIONAL

TK

ZV

PARAPET, TYP.

City of Aurora Building DivisionZL ZU ZK S

Reviewed for Code Compliance Approved as Noted: Richard LaCoste Date: Oct 05, 20122006 INTERNATIONAL CODES & 2008 NEC

106 West 11th Street Suite 1900 Kansas City, Missouri 64105 Phone : 816-842-7552 Fax : 816-842-1302DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT

TYP.

12 A3.62

EXTERIOR BOX OFFICE WALL ELEVATION B- EXISTING 5 1/8" = 1'-0"

683943 RSN: XXXXXX Permit #: 12-626423 YYYY-ZZZZZZ-AA

ZL GENERAL EXTERIOR NOTES: 1. GC TO INSPECT SEALANT AT CONTROL JOINTS, BUILDING TO PAVEMENT, FINISH TRANSITIONS AND PARAPETS. PROVIDE SEPARATE PROPOSAL IF AFTER INSPECTION SEALANT IS FOUND TO BE MISSING, DETERIORATED OR REQUIRING REPLACEMENT FOR THOSE AREAS. INCLUDE PHOTOS AND SPECIFIC AREA LOCATIONS.

ZU S

THEATRE SIDE ELEVATION - EXISTING 3 3/32" = 1'-0"

2. GC TO INSPECT EXTERIOR DOOR WEATHER STRIPPING AND PROVIDE A SEPARATE PROPOSAL IF MISSING OR DETERIORATED AND REQUIRING REPLACEMENT. 3. PAINTED SURFACES TO BE REPAINTED AND MAY INCLUDE EXTERIOR DOORS, GATES, TRASH ENCLOSURES, BOLLARDS, SOFFITS, GAS LINES, EXTERIOR STAIRS AND PARAPET CAPS.

ZV

PARAPET, TYP.

ZK

TYP.

ZM

A TYP.

PERMIT SET 10.01.2012Revision Schedule Rev Rev Rev # Date Description 2 THEATRE REAR ELEVATION - EXISTING 3/32" = 1'-0"

ZH ZL TYP.

ZL

ZL

ZV

ZV PARAPET, TYP. ZV PARAPET, TYP.

PROJECT # 12057

ZL

ZL TYP. ALL NEON

ZV

ZK

ZZG TYP. ZV TYP. ZK

ELEVATIONS DEMO EXTERIOR

ZL ZZH ZZH ZU S

TYP.

SHEET NUMBER

ZV

ZV

PREPARE FOR TICKETING KIOSKS. PROVIDE POWER AND DATA.

A1.501 ENTRY ELEVATION - EXISTING 3/32" = 1'-0"

AURORA, CO CUSA #428

EXTERIOR BOX OFFICE WALL ELEVATION A-EXISTING 4 1/8" = 1'-0"

3'-4 3/8" OVERALL HEIGHT

Keynote Legend - NEW 22'-2" OVERALL LENGTH 109 P-3 103 82 21 51 58 59 61 80 81 81 82 83 91 101 102 103 104 105 109 82 111 131 137 INSTALL NEW DOOR AND FRAME. PAINT INTERIOR FRAME BLACK AND EXTERIOR FRAME P-X. NEW SIGNAGE BY CINEMARK VENDOR. GC TO PROVIDE POWER AND BLOCKING. INSTALL NEW ELECTRICAL CONNECTION FOR BLADE SIGNAGE. REFERENCE MEP DRAWINGS. INSTALL NEW POSTERCASES. PROVIDE POWER AND BLOCKING. INSTALL A BEAD OF SEALANT BETWEEN THE POSTER CASES AND THE EXISTNG WALL FINISH. EXISTING FINISHES TO REMAIN. POWER WASH AND RESEAL WITH WATER REPELLANT INSTALL NEW TICKETS KIOSKS. PROVIDE BLOCKING AND POWER AS REQUIRED NEW MURAL BY CINEMARK VENDOR. PREPARE WALL TO RECEIVE MURAL TO LEVEL 5 FINISH ADD MURAL LIGHTING TO TOWER. RE: MEP. INSTALL NEW SCONCES AND DECORATIVE METAL BACKING IN LOCATION OF EXISTING, INSTALLED BY SIGNAGE VENDER. RE: MEP. SAND, PREP AND PAINT DOORS ON EXTERIOR SIDE, P-X INSTALL PUSH BUTTON ENTRY TO EXISTING DOOR PER ADA REQUIREMENTS. RE: MEP EXISTING STOREFRONT TO REMAIN. PAINT EXISTING EXTERIOR WALL AS SHOWN, RE: FINISH SCHEDULE. NEW TILE FINISH APPLIED TO EXISTING EXTERIOR WALL, RE: FINISH SCHEDULE. REUSE EXISTING CAP AND FLASHING. NEW SIGNAGE ON FACE OF CANOPY BY VENDER. GC TO ADD POWER AND BLOCKING AS REQUIRED EXISTING RAILING TO REMAIN. INSTALL NEW SCONCE AND DECORATIVE METAL BACKING, INSTALLED BY SIGNAGE VENDER. RE: MEP. PAINT EXISTING EIFS WALLS AND SOFFIT, P-X

362S162-43 (FY=33KS:) VERTICAL STUD @ 16" O.C.

P-4 103 P-7 3'-0" TYP. P-5 103 103

8

BOX OFFICE NEW WALL DETAIL B 1" = 1'-0"

4'-0" HEIGHT

362T125-43 (FY=33KS:) RUNNER TRACK WITH (2) #12 SDS TO TRACK AND (1) #10 SDS TO EA. STUD FLANGE

a r c h i t e c t sINTERNATIONAL

TK

P-3

61 WT-1 EXISTING 6" STUD STAGGERED P-4 103

106 West 11th Street Suite 1900 Kansas City, Missouri 64105 Phone : 816-842-7552 Fax : 816-842-1302DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT

1'-10" TYP.

EXISTING STUD BRACE 362S162-43 TIE WITH (4) #10-14 SDS TO STUD & (2) #12 SDS TO TRACK

EXTERIOR BOX OFFICE WALL ELEVATION B- PROPOSED 5 1/8" = 1'-0"

91

83

TYP. THIS ELEVATION

91

91 104 WT-1

362S162-43 (FY=33KS:) VERTICAL STUD @ 16" O.C.

362T125-43 (FY=33KS:) RUNNER TRACK CONTINUED WITH (1) 1/4" DIAMETER x 1 1/2" HILTI KWIK BOLT TZ @16" O.C. WITH (1) #10-14 SDS @EA. STD FLANGE

GENERAL EXTERIOR NOTES: WT-1 STAGGERED

3

THEATRE SIDE ELEVATION 3/32" = 1'-0"

1. GC TO INSPECT SEALANT AT CONTROL JOINTS, BUILDING TO PAVEMENT, FINISH TRANSITIONS AND PARAPETS. PROVIDE SEPARATE PROPOSAL IF AFTER INSPECTION SEALANT IS FOUND TO BE MISSING, DETERIORATED OR REQUIRING REPLACEMENT FOR THOSE AREAS. INCLUDE PHOTOS AND SPECIFIC AREA LOCATIONS. 2. GC TO INSPECT EXTERIOR DOOR WEATHER STRIPPING AND PROVIDE A SEPARATE PROPOSAL IF MISSING OR DETERIORATED AND REQUIRING REPLACEMENT.

P-3 103

P-4 103 P-7 103 P-5 103 4'-0" P-5 103 3'-0" TYP. P-5 103

P-3

P-3

61

61

61

61

61

83 TYP. THIS ELEVATION 137

111

111

137

PERMIT SET111 91

91

111 21

10.01.201291 91 91 91 91 91 91 91

2

THEATRE REAR ELEVATION 3/32" = 1'-0"

Revision Schedule Rev Rev Rev # Date Description

City of Aurora Building Division

Reviewed for Code Compliance Approved as Noted: Richard LaCoste Date: Oct 05, 20122006 INTERNATIONAL CODES & 2008 NEC

58

P-3 103 P-4 103

P-5 103 3'-0" TYP.

P-4 103

P-7 103

105 109

683943 RSN: XXXXXX Permit #: 12-626423 YYYY-ZZZZZZ-AA

P-5 103 3'-0" TYP.

PROJECT # 12057

1'-10" TYP.

51 4'-2 7/8" OVERALL HEIGHT

61 83 83 83 131

61

15'-5" SIGN LENGTH

ELEVATIONS PROPOSED EXTERIOR83 83

8'-9" SIGN HEIGHT

5'-0 7/8" HEIGHT

131

1'-10" TYP.

83

28' 0 5/8" OVERALL LENGTH 51 137

137

SHEET NUMBER

91

137

91

91

59

TYP.

59

104

101

102 WT-1 STAGGERED

104 102

104

102

80

104

59

91

91

137

91

A1.51

1

ENTRY ELEVATION - PROPOSED 3/32" = 1'-0"

AURORA, CO CUSA #428

7

BOX OFFICE NEW WALL DETAIL A 1" = 1'-0"

EXTERIOR BOX OFFICE WALL ELEVATION A-PROPOSED 4 1/8" = 1'-0"

3. PAINTED SURFACES TO BE REPAINTED AND MAY INCLUDE EXTERIOR DOORS, GATES, TRASH ENCLOSURES, BOLLARDS, SOFFITS, GAS LINES, EXTERIOR STAIRS AND PARAPET CAPS. 4. PATCH AND REPAIR AND EXISTING EIFS AS REQUIRED.

1'-10" TYP.

WALL FINISH LEGENDFIXTURE & ACCESSORY MOUNTING HEIGHTS 1/4" = 1'-0" STANDARD STALL STANDARD STALL LAYOUT ADA STALL LAYOUT 5'-9" CLR. TOILET PARTITION 7" 4" 3' - 5" TO C/L 12" MAX 6" 1'-6" V-3 WALL VINYL WC-1 WALL CARPET ADA STALL LAYOUT URINALS V-1 WALL VINYL 2' - 8" TO C/L EQ. TOILET PARTITION V-5 WALL VINYL

3'-0" CLR. EQ.

V-2 WALL VINYL

V-6 WALL VINYL

3'-6"

48" MAX

3'-6"

V-4 WALL VINYL

WC-2 WALL CARPET

15" MIN

1'-10"

WT-2A WALL TILE 1'-0" 3" 3" WT-2B 3" 6" 3" AA AB AF AJ F O P S T ZB ZV ZZB ZZC Keynote Legend - DEMO

WT-2B WALL TILE

ADA STALL

a r c h i t e c t sINTERNATIONAL

7" TO 9"

URINALS MIN 30" CLR BETWEEN URINAL SCREENS TYP. STANDARD URINAL 22" TO RIM ADA URINAL 17" TO RIM

URINAL DIVIDER WITH FULL HEIGHT WALL BRACKET & END FLOOR SUPPORTSLO FOR D PE RAINA GE

TK

2'-8"

2'-8" 1'-5"

WT-2A

NOTE: INSTALLER TO REFER TO & COMPLY WITH ALL LOCAL CODES/ ANSI REGULATIONS WHEN SETTING OUT ALL ACCESSIBLE TOILET ROOM ACCESSORIES. THESE WILL SUPERSEDE ANY DIMENSIONS SHOWN ON PLANS. REFER TO TOILET ACCESSORY SCHEDULE FOR ADDITIONAL INFORMATION.

STANDARD N/A N/A PER ELEVATION KEY

ACCESSIBLE 3" 33" TO TOP 33" TO TOP BELOW GRAB BAR- MIN 15" FROM FFL TO BOTTOM OF UNIT WITH MIN 2" CLR FROM RAIL ABOVE GRAB BAR - MIN 12" CLEAR FROM RAIL BELOW, MAX TO TOP OF UNIT 48" ABOVE FFL. MIN 7" - MAX 9" TO C/L OF TOILET PAPER DISPENSER FROM FRONT MOST PART OF WC 52" TO TOP 45" TO TOP PER ELEVATION KEY 46" MAX TO C/L OF SLOT 32" TO TOP OF TABLE IN HORIZONTAL POSITION 44" TO PUSH BUTTON MAX 46" TO TOP SS-1 124

EXISTING WALL TILE 12 FULL WALL TILE AND BASE

TOILET ACCESSORY SCHEDULE 42" STAINLESS STEEL GRAB BAR. 1 1/2" DIAMETER (MOUNT HORIZONTALLY) 36" STAINLESS STEEL GRAB BAR. 1 1/2" DIAMETER (MOUNT HORIZONTALLY) TOILET TISSUE DISPENSER

TOILET ACCESSORY SCHEDULE

1'-9 1/2" CRITICAL

4"

HOLD STEEL 4" OFF BACK WALL (STEEL BY OTHERS) CONT. 2"x3" STEEL TUBE HORIZONTAL SUPPORT TO EXTEND TO VERTICAL STEEL TUBE LEG

2'-8 1/2"

2'-4" MIN. WING WALL (BY OTHERS)

SUPPORTS IN WALL ANCHORED TO FLOOR (BY CONTRACTOR). OPEN WALL AS REQUIRED TO INSTALL STEEL. SALVAGE TILE FOR REINSTALLATION OR REPLACE TILE WITH NEW TO MATCH EXISTING. NOTE: THIS DRAWING SHOWS FINISHED STEEL REQUIREMENTS FOR CONTRACTOR

24" STAINLESS STEEL GRAB BAR. 1 1/2" DIAMETER (MOUNT VERTICALLY) PAPER TOWEL DISPENSER FEMININE TAMPON/NAPKIN DISPOSAL TOILET SEAT COVER DISPENSER BABY CHANGING STATION SOAP DISPENSER DOOR PULL FOR ACCESSIBLE & AMBULATORY STALLS ONLY INSTALL BOTH SIDES OF DOOR

N/A 45" TO TOP PER ELEVATION KEY 46" MAX TO C/L OF SLOT 32" TO TOP OF TABLE IN HORIZONTAL POSITION 44" TO PUSH BUTTON N/A

ZZD ZZE ZZT ZZZ NOTE: FLOAT GLASS TILE AS REQUIRED TO BE FLUSH WITH EXISTING TILE TO REMAIN.

MOST EXISTING WALL FINISHES TO REMAIN . REFERENCE ELEVATIONS FOR MORE DETAIL AND INSTRUCTION. REMOVE EXISTING DOOR FRAME AND DOOR STOP. PREP FOR NEW WORK. DEMO EXISTING SINKS. REMOVE AND SAVE FAUCETS TO BE RE-INSTALLED. DEMOLISH EXISTING DOOR STOP AND SAVE FOR REINSTALLATION REMOVE EXISTING WALL FINISHES AND PREPARE FOR NEW FINISHES REMOVE EXISTING FLOOR FINISH EXISTING FLOOR FINISHES TO REMAIN. REPAIR AND MAKE GOOD AS REQUIRED BY WORKS REMOVE EXISTING WALL FINISHES IN PREPARATION FOR NEW FINISHES. EXISTING WALL FINISHES TO REMAIN DEMOLISH WALL AS SHOWN TO ALLOW FOR NEW WORK. (NOTE: LOW WALLS MAY CONTAIN ADDITIONAL STEEL POSTS ALSO REQUIRING DEMOLITION) PREPARE FOR NEW FINISHES. DEMOLISH EXISTING SOLID SURFACE COUNTER TOP AND PREP FOR NEW COUNTER. DEMOLISH EXISTING RESTROOM PARTITIONS AND PREP FOR NEW PARTITIONS IN THE SAME LOCATION. SALVAGE ALL HARDWARE, GRAB BARS AND ACCESSORIES FOR REINSTALLATION WITH THE EXCEPTION OF THE TOILET PAPER DISPENSERS WHICH ARE TO BE NEW. EXISTING RESTROOM FIXTURES TO REMAIN EXISTING MIRRORS TO REMAIN DEMO EXISTING DOOR AND FRAME. DEMOLISH EXISTING SOLID SURFACE COUNTER TOP. REMOVE COUNTER SUPPORT AND LAVS AND SAVE FOR REINSTALLATION IN NEW LOCATION.

106 West 11th Street Suite 1900 Kansas City, Missouri 64105 Phone : 816-842-7552 Fax : 816-842-1302DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT

6

VANITY STEEL FRAME SECTION 1" = 1'-0"

TYPICAL RESTROOM ELEVATION PROPOSED 5 1/2" = 1'-0"

Keynote Legend - NEW WT-2 L-5 57 75 76 77 77 NEW DEMISING WALL TO DECK. REMOVE CEILING TILE AND GRID AS REQUIRED FOR NEW WORK. SALVAGE TILE, WALL ANGLE AND GRID TO BE REINSTALLED NEW SOLID SURFACE COUNTER TO BE INSTALLED BY CINEMARK INSTALL NEW WALL TILE. REFER TO TYPICAL RESTROOM ELEVATIONS NEW RESTROOM PARTITIONS INSTALLED BY CINEMARK VENDOR. INSTALL ALL HARDWARE AND ACCESSORIES AS REQUIRED PER MOUNTING HEIGHT SCHEDULE. NEW TOILET PAPER DISPENSERS INSTALLED BY CINEMARK INSTALL NEW VERTICAL GRAB BAR IN STALL IF NOT EXISTING. RE: TOILET ACCESSORY SCHEDULE FOR MOUNTING HEIGHT EXISTING TILE TO REMAIN SAND, PREP AND PAINT EXISTING COLUMNS, P-X. INFILL WILL BE SALVAGED PROMENADE TILE AROUND THE OPENING. INSTALL NEW SINKS AND RE-INSTALL FAUCETS. INSTALL SALVAGED TILE TO MATCH EXISTING WALL TILE PATTERN. NEW WALL TILE FULL HEIGHT NEW WALL TO DECK PER WALL KEY RE-INSTALLED DOOR STOP

NOTE: ALL DIMENSIONS ARE FROM THE FINISHED FLOOR LINE

76

78 79 85 120 124 126 127 141 144

TYPICAL RESTROOM ELEVATION PROPOSED 3 1/4" = 1'-0"SLOPES

EXISTING BOX OFFICE FINISHES TO REMAIN UNLESS NOTED OTHERWISE

SS-4 ADA APPROVED INTEGRAL BOWL 4 7/8". SS-1 COUNTER TOPR1

TOWAR DS WAL L

1/8"

2'-0"

1"/4"

4"

3"

4 3/4"

BOX OFFICE B14285 TRIM EXISTING CASEWORK AS REQUIRED TO ALLOW FOR NEW WALL TO BOTTOM OF SOFFIT EXISTING CASEWORK TO REMAIN 141 EXISTING FLOOR FINISHES TO REMAIN 141 141 2 V-1 CENTER NEW WALL ON EXISTING COLUMN 2'-9 3/4" 141

4 1/4" 2" 1'-5 1/2" CRITICAL 1'-9 1/2" CRITICAL 2"

10 A3.10

ZZE

ZZB 2'-9 3/4"

ZZC

City of Aurora Building Division

COUNT ROOM B207

Reviewed for Code Compliance Approved as Noted: Richard LaCoste Date: Oct 05, 20122006 INTERNATIONAL CODES & 2008 NEC

PAINT WALLS INSIDE COUNT ROOM P-4 NOTES:

2'-5"

PERMIT SET 10.01.2012

AF

ENLARGED BOX OFFICE PLAN 12 1/8" = 1'-0"

ADD PIPE COVERS ON P TRAPS PER ADA REQUIREMENTS. ADD STEEL TUBES TO BACK WALL AS REQUIRED FOR ADDITIONAL SUPPORT AT WOMEN'S RESTROOM VANITIES. FAUCETS TO REMAIN IN CURRENT LOCATION

TYPICAL RESTROOM ELEVATION EXISTING 4 1/4" = 1'-0" VANITY SECTION 9 1" = 1'-0"SS-1 VANITY, TYP. 8'-0" 3'-0" SS-4 BOWL, TYP. 2'-6" 2'-6" 1'-8" 77 TYP. 78

683943 RSN: XXXXXX Permit #: 12-626423 YYYY-ZZZZZZ-AA

Revision Schedule Rev Rev Rev # Date Description

2'-6" ZZC 1" HOLE (FAUCET BY OTHRES) TYP. ZZD TYP. ZB AF ZZZ ZZB AF ZZD TYP. ZZC TYP. 127 141

2'-6"1'-7 3/4"

5'-0"

ZZT F F ZV O F ZB AA P ZZC AA

AA F O ZV AA TYP. O ZB ZV AB AA AB AA TYP. P 124 127

3/4" PLYWOOD SUBTOP 1" 2"x3" TUBE STEE, HELD 4" OFF BACK WALL. (STEEL FRAMING AND SUPPORTS BY OTHERS) 4 1/4" 1" 3"

57 75 TYP. TYP.

78 141 127 1'-9" 77 TYP. 57 75 120 9 A3.10

124 TYP.

3 A3.10

127

141

126 AJ ZB F ZB T 141 144 126 141 126

141 EQ EQ 57 3'-0" 8'-0" 78

5'-0" TYP.

57

5'-0"

4"

3"

1/8"x1/8" DRIP QUIRK.

DRIP EDGE DETAIL 10 3" = 1'-0"

ENLARGED RESTROOM PLAN B EXISTING 8 1/8" = 1'-0"SS-4 BOWL, TYP. ZZD TYP. ZZC TYP. AF TYP. ZZB AF TYP. ZZZ ZB ZZC TYP. F 78 77 TYP. 1'-8" 2'-6" 2'-6"

ENLARGED RESTROOM PLAN B PROPOSED 2 1/8" = 1'-0"SS-1 VANITY, TYP.

PROJECT # 12057

GENERAL TILE INSTALLATION NOTES 1. ALWAYS USE PRE MANUFACTURED INSIDE & OUTSIDE CORNERS AT TILE BASE. 2. WHERE TILE MEETS VINYL WALL COVERING INSTALL WALL COVERING FIRST & EXTEND A MINIMUM OF 6" BEHIND WALL TILE.

MITER CORNERS OF TRIM PIECE 3'-0" EQ EQ 77 TYP. 8'-0" 78 1'-8" 2'-6" 141 2'-6" 75

WALL TILE

C

OUTSIDE CORNER

INSIDE CORNER P MILLWORK (BY OTHERS) TO SIT ON CONCRETE FLOOR

AA

F TYP. AB AB O ZV

AA

AA ZB AA

F

ZZT

75 124

9 TYP. A3.10 120 141 127

124

3 TYP. A3.10 4'-0"

127

ENLARGED PLANS & ELEVATIONS RESTROOMS & BOX OFFICESHEET NUMBER

5'-0"

AA

P

F 5'-0"

5'-0"

141 ZZC ZB TYP. ZZD EQ EQ TYP. 78 8'-0" 3'-0" 141 126 141 141 1'-3"

1'-9"

WALL TILE

COVE TILE BASE

ZB

O

ZV

141 4'-0" 141 126 126

127

F

1'-3"

B

WALL TILE DETAIL AT WING WALLS

A11

FLOOR TILE AT MILLWORK BASE. NEW RESTROOM WALL TILE BASE SIM.

ZB T

TYPICAL TILE DETAILS 3" = 1'-0"

ENLARGED RESTROOM PLAN A EXISTING 7 1/8" = 1'-0"

ENLARGED RESTROOM PLAN A PROPOSED 1 1/8" = 1'-0"

A3.10

AURORA, CO CUSA #428

ZZA ZZX G M 74 1'-2" ZC 118 74 15

SINGLE SIDE APPROACH WHEELCHAIR SPACE TO HAVE CLEAR FLOOR SPACE OF 36"x60" MIN. SINGLE WHEELCHAIR SPACE TO HAVE CLEAR FLOOR SPACE OF 36"x48" MIN. DOUBLE WHEELCHAIR SPACE TO HAVE CLEAR FLOOR SPACE OF 66"x48" MIN. EVERY WHEELCHAIR SPACE MUST HAVE A COMPANION SEAT CONFIRM WITH OWNER PRIOR TO REMOVAL ANY FINISHES PROTECT ALL FINISHES FROM DAMAGE REMOVED MATERIALS/FINISHES TO BE RECYCLED WHEN POSSIBLE INCLUDING CARPET, CEILING TILES, WALL COVERINGS AND METALS MINIMUM RISER HEIGHT 4" (STAIRS) MINIMUM TREAD DEPTH 12" (STAIRS) MINIMUM SEAT BACK HEIGHT: 44" EXISTING CONDITION DIMENSIONS ARE FROM FACE OF GYP. PROPOSED DIMENSIONS ARE FROM FACE OF EXISTING FINISH

1'-2"

1'-2"

27 72 90 74

1'-2"

TYP.

74 12'-0"

39 NEW WALL

EXISTING ELEVATION TO REMAIN PROPOSED ELEVATION

L

ZA

ZA

L ZZP

EXISTING DOOR TO REMAIN 11 32 11 94 7 20 7 NEW DOOR 3D 2/A1

a r c h i t e c t sCALLOUT OF 3D VIEW EXISTING AUDITORIUM CARPET TO REMAININTERNATIONAL

TK

20 20

Keynote Legend - DEMO MAINTAIN EXISTING DOOR. SEATS REMOVED BY OWNER GRIND ANCHORS FLUSH AND PATCH CONCRETE AS DIRECTED-RE: GENERAL NOTES G REMOVE EXISTING 1X4 DRAPERY TRIM TO ALLOW FOR NEW DRAPERY AND REINSTALLATION. PAINT EXISTING AND NEW TRIM BLACK. K EXISTING LOW WALL TO REMAIN L REMOVE EXISTING HANDRAIL. M REMOVE ALL SIDEWALL FINISHES. PROTECT SPEAKER WIRES AND INSULATION FROM DAMAGE DURING WORK. ANY DAMAGE TO SPEAKER WIRING WILL BE REPLACED BY GC TO SOURCE. U DEMOLISH PORTION OF FLOOR TO ALLOW FOR NEW RAMPING. V REMOVE EXISTING AISLE LIGHTING, CAP OFF AND REPAIR FLOOR AS REQUIRED ZA DEMO/REWORK CONCRETE STAIR TO ALLOW FOR NEW WORK. RE STRUCTURAL. ZC EXISTING CEILING TO REMAIN. ZD EXISTING SLAB TO REMAIN ZI TEMPORARILY REMOVE WOOD CAP FOR NEW FINISHES AND NEW WORK. (BOTH SIDES OF WALL) ZJ REMOVE EXISTING PLAQUE AND PREP WALL FOR NEW PLAQUE. ZK DEMOLISH EXISTING WALL SCONCES AND TEMPORARILY CAP POWER AS REQUIRED AND PREP WALL FOR NEW SCONCE. RE: MEP ZR PROTECT AND MAINTAIN EXISTING CARPET TO REMAIN. ZW DEMOLISH PORTION OF FLOOR TO ALLOW FOR NEW WORK. RE STURCTURAL. ZX GC TO REMOVE EXISTING SURROUND SPEAKER AND SAVE FOR REINSTALLATION. TEMPORARILY CAP ELECTRICAL AND PROTECT FROM DAMAGE AND CONSTRUCTION DUST PARTICLES.PROTECT BRACKET, MOUNTING, AND BLOCKING FOR REUSE IN REINSTALLATION. ZZ EXISTING PORT WINDOW TO REMAIN. ZZA GC TO REMOVE EXISTING SURROUND SPEAKER AND BRACKET. SAVE FOR REINSTALLATION IN NEW LOCATION.PROTECT WIRING AND INSULATION. ZZP EXISTING SCREEN & FRAME TO REMAIN. G.C. TO PROVIDE HEAVY DUTY SHEET PLASTIC PROTECTION 1" IN FRONT OF SCREEN & SECURE TO WALLS, FLOORS, AND CEILING. ANY DAMAGES TO WALLS, FLOORS AND CEILING BY G.C. FROM SECURING PROTECTIVE PLASTIC WILL BE REPAIRED BY G.C. ANY DUCTWORK OR RETURNS BEHIND PROTECTIVE PLASTIC TO BE FULLY SEALED PRIOR TO START OF DEMOLITION OR CONSTRUCTION. FAILURE TO PROTECT SCREENS, FRAME OR SPEAKERS FROM AIRBORNE DUST WILL RESULT IN REPLACEMENT OF SCREEN OR COMPONENT BY G.C. ZZX EXISTING DRAPERY NAILER TO BE SALVAGED AND REUSED FOR INSTALLATION OF NEW DRAPERY A D

106 West 11th Street Suite 1900 Kansas City, Missouri 64105 Phone : 816-842-7552 Fax : 816-842-1302DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT

ZW

L

ZW

L

ZW

7

AUD. A EXISTING REAR WALL ELEVATION (AUD. P SIM) 13 1/8" = 1'-0"

AUD. A EXSTING SCREEN ELEVATION (AUD. 16 SIM) 9 1/8" = 1'-0"

AUD. A PROPOSED REAR WALL ELEVATION (AUD. P SIM) 5 1/8" = 1'-0"

AUD. A PROPOSED SCREEN ELEVATION (AUD. P SIM) 4 1/8" = 1'-0"

ZZX ZC M ZK WITHIN FRONT 25% & IN FRONT OF CROSS AISLE ZK ZX G ZK ZX L ZZA

ZK

ZZA G

118

39

27 74

74

D-1 94 31 L 15 90 WC-3 14 TYP. 70 TYP. 70 20

32

L

ZW

32

MAINTAIN CLEARANCE FOR RAIL AT VOMITORY WALL FROM WOOD CAP. TYP. WHERE IT OCCURS. SEE 9/A3.61 FOR TYPICAL WALL EXTENSION ELEVATION

12

AUDITORIUM #A 3D VIEW 'C'

8

AUD. A SECTION EXISTING (AUD. P SIM) 1/8" = 1'-0"

AUD. A SECTION PROPOSED (AUD. P SIM) 3 1/8" = 1'-0"

17

R1 7

K L SEE HANDRAIL NOTE 18 ON A0 REGARDING COMBINED R2 AND R3B WHERE IT OCCURS IN AUDITORIUMS TYP. L

ZI

L

7 R1

11 R3B R2

12

ZW

ZA

100' - 5 1/2"

7 R1

17

48 Keynote Legend - NEW

100' - 0"

100' - 9"

103' - 3"

104' - 9"

106' - 3"

107' - 9"

109' - 3"

110' - 9"

112' - 3"

113' - 9"

115' - 3"

100' - 0"

ZZP

L

116' - 9"

V

7 10 113D .60 /A3 11

AUDITORIUM A A130 297 SEATS INCL 4 ADA SPACES

103' - 3"

104' - 9"

106' - 3"

107' - 9"

109' - 3"

110' - 9"

112' - 3"

113' - 9"

115' - 3"

D TYP.

ZW

D

ZZ TYP.

116' - 9"

12 13 14 72 15

AUDITORIUM A A130282 SEATS INCL 5 ADA SPACES ZD L 14 TYP. 24 V TYP. 7 ZW 18 L ZW L K ZI L 18 18 18 18 11 17 16 16 16 7 R1 R3B 16 16 7 R2 12 19 19

17

19

19

24

20 24 27 31 32 38 39 48 64 69

100' - 5 1/2"

17

7 R1

11

AUDITORIUM #A 3D VIEW 'B'

7

AUD. A - MEZZANINE - EXISTING 1/8" = 1'-0"15'-0" 1:12 RAMP 6'-6" CLR. 15'-0" 1:12 RAMP

2

AUD. A - MEZZANINE - PROPOSED 1/8" = 1'-0"

70 71 72 74

5'-0" CLR.

A

L

V

K

ZI

L

U A

10

7

R1 7 R3

17

17

7 R1 7 R1

10

64

ZW ZR 100' - 0" 100' - 9" 103' - 3" 104' - 9"

1 100' - 0" A3.61 2

38

7 R1

12 R2 101' - 3" 71 MIN. 3'-0" 1'-0" CLR. 103' - 3" 104' - 9" 130 89 90 94

NEW HANDRAIL REF: RAIL KEY. OVERPOUR NEW SLOPE/RAMP AND LANDINGS LOW WALL TO BE EXTENDED TO 3'-6" A.F.F. (36" AT CROSSOVER WALL) INSTALL NEW WALL CARPET AND WOOD CAP. FOLLOW RAKE OF STAIRS AND LANDINGS. WALL CARPET TO WRAP TOP OF WALL BY 2" EACH SIDE PRIOR TO INSTALL OF WOOD CAP. REWORK/OVERPOUR NEW SEATING PLATFORM AND AISLE STAIRS OVERPOUR EXISTING AS SHOWN NEW SEATS INSTALLED BY OWNER, VERIFY FINAL SEATING LAYOUT W/ CINEMARK AND SEATING VENDOR SHOP DRAWINGS PRIOR TO ANY ADJACENT WORK INCLUDING BUT NOT LIMITED TO INTERMEDIATE STEPS, CONCRETE, VCT, AND CARPET INSTALL/REINSTALL 1X4 DRAPERY TRIM AS REQUIRED BY WORKS. RE-PAINT ALL EXISTING WOOD TRIM IN THE AUDITORIUMS BLACK. ADJUSTMENTS MAY BE REQUIRED BASED ON CROSS OVER AISLE WALL HEIGHT MODIFICATIONS. INSTALL NEW AISLE LIGHTING, CONNECT TO EXISTING POWER. AISLE LIGHTING SET AT 0.3 FC USING A MANUAL DIMMER THAT IS A BOX AND NOT PART OF THE AUTOMATION AND NOT MARKED. ALL WIRING TO BE CONCEALED. PAINT CAPS ON PONY WALL P-3 AND REINSTALL. PAINT ALL EXPOSED RISER & SIDE OF AISLE STAIRS & PER DETAIL FACES BLACK. ALL NEW DRAPERY BY OWNER VENDOR. ADD 1X4 BLOCKING TO BACK WALL. INSTALL NEW SCONCES PER DETAIL ON A3.73 INSTALL NEW WALL CARPET SUPPORT R1 RAIL OFF ADJACENT RAIL EXISTING CEILING TO REMAIN. VERIFY RAIL LENGTH WITH SEATING SHOP DRAWINGS. INSTALL FULL HEIGHT BLACK CORNER GUARDS SCREEN, FRAME, SPEAKERS, SPEAKER SUPPORT AND MASKING PER CINEMARK CRITERIA. GC TO COORDINATE POWER AND BLOCKING WITH CINEMARK. G.C. TO COORDINATE WITH CINEMARK CRITERIA LOCATIONS FOR ALL SCREEN SUPPORTS. FRAME TO BE ADJUSTED AS REQUIRED. REINSTALL SPEAKERS ONTO EXISTING BRACKET AND BLOCKING. ANY DAMAGE TO SPEAKER WIRING WILL BE REPLACED BY GC TO SOURCE. WARP SLOPE FROM NEW PLATFORM TO MATCH ADJACENT EXISTING SLOPE ELEVATIONS. EXISTING PORT WINDOW TO REMAIN. INSTALL NEW SPEAKER BLOCKING AND BRACKET, SIZE PER OWNER PROJECT MANAGER DIRECTIVE. REINSTALL EXISTING SPEAKER IN NEW VERTICAL LOCATION, HORIZONTAL DIMENSIONS ARE TO BE THE SAME AS PREVIOUS.NOTIFY ARCHITECT IF COILED EXTRA SPEAKER WIRE IS INSUFFICIENT TO REACH NEW LOCATION.IF INSUFFICIENT, NEW SPEAKER WIRE MAYBE REQUIRED TO BE RUN TO SOURCE. DO NOT SPLICE SPEAKER WIRE. EXISTING DOOR AND FRAME TO REMAIN. SAND, PREP AND PAINT DOOR FRAME P-1 EXISTING TRIM TO REMAIN. PAINT BLACK COORDINATE REMOVAL OF PROTECTIVE BARRIERS WITH CINEMARK PROJECT MANAGER TO ALLOW FOR FINISH WORK ADJACENT TO SCREEN. NO DRY WALL, CONCRETE, OR OTHER DUST GENERATING WORK AFTER REMOVAL. REUSE EXISTING DRAPERY NAILER. INSTALL ACCESS PANEL KEYED WITH COMPRESSION LATCH WHERE EXISTING ACCESS OCCURS. KARP-450FR OR APPROVED EQUAL, SIZE 24X24. VERIFY SIZE WITH CINEMARK PROJECT MANAGER. PATCH AND FRAME WALL AS REQUIRED FOR ACCESS PANEL OPENING

101' - 3"

PERMIT SET 10.01.2012Revision Schedule Rev Rev Rev # Date Description

2'-0"

3'-3"

PROJECT # 12057

L 9 A3.60 133D 10 /A3 .60 AUDITORIUM A A130 291 SEATS INCL 5 WHC

1'-1 1/4"

7'-4 3/4" 101' - 1" ZR GFOLLOW EXISTING R = 55' - 2 1/4"

118 130

AUDITORIUM A A130297 SEATS INCL 4 ADA SPACES

SLOPE D TYP.

14

TYP.

13

7 69 SLOPE

3 A3.60

City of Aurora Building Division32

5 100' - 9" A3.61 6

L K ZI ZR 4 A3.60 5 100' - 5 1/2" 71 2 1/4" 17 7 7 10 64 R2

Reviewed for Code Compliance Approved as Noted: Richard LaCoste Date: Oct 05, 20122006 INTERNATIONAL CODES & 2008 NEC

ENLARGED PLANS & ELEVATIONS AUDITORIUM A (AUD. P SIM)SHEET NUMBER

A L ZW V L U ZJ

3'-6" CLR.

7 R1

2'-0"

89

12

R1 SUPPORTED OFF R3 , ALL ENDS RETURN TO FLOOR POST OR LOWER RAIL TYP. WHERE OCCURS 1'-7 1/4"

MIN. 3'-0" CLR.

6'-11 1/2" 1'-0"

15'-0" 1:12 RAMP

10

AUDITORIUM #A 3D VIEW 'A'

AUD. A - FIRST FLOOR EXISTING 6 1/8" = 1'-0"

AUD. A - FIRST FLOOR PROPOSED 1 1/8" = 1'-0"

683943 RSN: XXXXXX Permit #: 12-626423 YYYY-ZZZZZZ-AA

A3.60

AURORA, CO CUSA #428

11'-3"

3D X/A 3.6 1

SINGLE WHEELCHAIR SPACE TO HAVE CLEAR FLOOR SPACE OF 36"x48" MIN. DOUBLE WHEELCHAIR SPACE TO HAVE CLEAR FLOOR SPACE OF 66"x48" MIN. EVERY WHEELCHAIR SPACE MUST HAVE A COMPANION SEAT CONFIRM WITH OWNER PRIOR TO REMOVAL ANY FINISHES PROTECT ALL FINISHES FROM DAMAGE REMOVED MATERIALS/FINISHES TO BE RECYCLED WHEN POSSIBLE INCLUDING CARPET, CEILING TILES, WALL COVERINGS AND METALS MINIMUM RISER HEIGHT 4" (STAIRS) MINIMUM TREAD DEPTH 12" (STAIRS) MINIMUM SEAT BACK HEIGHT: 44" EXISTING CONDITION DIMENSIONS ARE FROM FACE OF GYP. PROPOSED DIMENSIONS ARE FROM FACE OF EXISTING FINISH

NEW WALL ZZX ZZA EQ TYP. EQ TYP. 118

EXISTING AUDITORIUM CARPET TO REMAIN

a r c h i t e c t s39INTERNATIONAL

G

ZX

AUDITORIUM B A116M ZK ZX ZX

ZC R

15 32

TK

74

70

27 31 70 TYP.

AUDITORIUM B A116 155 SEATS INCL 5 WHC70 15

G ZI 7 20

Keynote Legend - DEMO A G MAINTAIN EXISTING DOOR. REMOVE EXISTING 1X4 DRAPERY TRIM TO ALLOW FOR NEW DRAPERY AND REINSTALLATION. PAINT EXISTING AND NEW TRIM BLACK. L REMOVE EXISTING HANDRAIL. M REMOVE ALL SIDEWALL FINISHES. PROTECT SPEAKER WIRES AND INSULATION FROM DAMAGE DURING WORK. ANY DAMAGE TO SPEAKER WIRING WILL BE REPLACED BY GC TO SOURCE. R REMOVE EXISTING WALL SCONCES. REMOVE CONDUIT AND CAP ELECTRICAL. PROVIDE SCONCES TO OWNER ZC EXISTING CEILING TO REMAIN. ZG REMOVE EXISTING SCREEN AND FRAME, DEMO ALL CONNECTIONS AND REPAIR ALL SURFACES TO BE SMOOTH AND FLUSH FOR NEW WORK ZI TEMPORARILY REMOVE WOOD CAP FOR NEW FINISHES AND NEW WORK. (BOTH SIDES OF WALL) ZK DEMOLISH EXISTING WALL SCONCES AND TEMPORARILY CAP POWER AS REQUIRED AND PREP WALL FOR NEW SCONCE. RE: MEP ZP EXISTING EXIT SIGN TO REMAIN. RE: MEP ZW DEMOLISH PORTION OF FLOOR TO ALLOW FOR NEW WORK. RE STURCTURAL. ZX GC TO REMOVE EXISTING SURROUND SPEAKER AND SAVE FOR REINSTALLATION. TEMPORARILY CAP ELECTRICAL AND PROTECT FROM DAMAGE AND CONSTRUCTION DUST PARTICLES.PROTECT BRACKET, MOUNTING, AND BLOCKING FOR REUSE IN REINSTALLATION. ZZA GC TO REMOVE EXISTING SURROUND SPEAKER AND BRACKET. SAVE FOR REINSTALLATION IN NEW LOCATION.PROTECT WIRING AND INSULATION. ZZP EXISTING SCREEN & FRAME TO REMAIN. G.C. TO PROVIDE HEAVY DUTY SHEET PLASTIC PROTECTION 1" IN FRONT OF SCREEN & SECURE TO WALLS, FLOORS, AND CEILING. ANY DAMAGES TO WALLS, FLOORS AND CEILING BY G.C. FROM SECURING PROTECTIVE PLASTIC WILL BE REPAIRED BY G.C. ANY DUCTWORK OR RETURNS BEHIND PROTECTIVE PLASTIC TO BE FULLY SEALED PRIOR TO START OF DEMOLITION OR CONSTRUCTION. FAILURE TO PROTECT SCREENS, FRAME OR SPEAKERS FROM AIRBORNE DUST WILL RESULT IN REPLACEMENT OF SCREEN OR COMPONENT BY G.C. ZZX EXISTING DRAPERY NAILER TO BE SALVAGED AND REUSED FOR INSTALLATION OF NEW DRAPERY

106 West 11th Street Suite 1900 Kansas City, Missouri 64105 Phone : 816-842-7552 Fax : 816-842-1302DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT

L A

32

AUD. B EXISTING SIDE WALL 'B' (AUD. O SIM) 8 1/8" = 1'-0"

AUD. B PROPOSED SIDE WALL 'B' (AUD. O SIM) 4 1/8" = 1'-0"

EXISTING ANGLED WALL

1'-2"

5'-0" TYP.

5'-0" TYP.

ZC ZZP R ZX

M ZK

ZZX

39 ZZA G 27

118

ZX G

94 15 ZI L 32 70

AUDITORIUM B A116 155 SEATS INCL 5 WHC70 70 20

31

TYP.

7

AUD. B EXISTING SIDE WALL 'A' (AUD. O SIM) 7 1/8" = 1'-0"

EQ TYP.

AUDITORIUM B A116

74 32

15

ZX

AUD. B PROPOSED SIDE WALL 'A' (AUD. 0 SIM) 3 1/8" = 1'-0"

Keynote Legend - NEW 7 15 NEW HANDRAIL REF: RAIL KEY. INSTALL/REINSTALL 1X4 DRAPERY TRIM AS REQUIRED BY WORKS. RE-PAINT ALL EXISTING WOOD TRIM IN THE AUDITORIUMS BLACK. ADJUSTMENTS MAY BE REQUIRED BASED ON CROSS OVER AISLE WALL HEIGHT MODIFICATIONS. PAINT CAPS ON PONY WALL P-3 AND REINSTALL. ALL NEW DRAPERY BY OWNER VENDOR. ADD 1X4 BLOCKING TO BACK WALL. INSTALL NEW SCONCES PER DETAIL ON A3.73 INSTALL NEW WALL CARPET EXISTING CEILING TO REMAIN. REINSTALL SPEAKERS ONTO EXISTING BRACKET AND BLOCKING. ANY DAMAGE TO SPEAKER WIRING WILL BE REPLACED BY GC TO SOURCE. INSTALL NEW SPEAKER BLOCKING AND BRACKET, SIZE PER OWNER PROJECT MANAGER DIRECTIVE. REINSTALL EXISTING SPEAKER IN NEW VERTICAL LOCATION, HORIZONTAL DIMENSIONS ARE TO BE THE SAME AS PREVIOUS.NOTIFY ARCHITECT IF COILED EXTRA SPEAKER WIRE IS INSUFFICIENT TO REACH NEW LOCATION.IF INSUFFICIENT, NEW SPEAKER WIRE MAYBE REQUIRED TO BE RUN TO SOURCE. DO NOT SPLICE SPEAKER WIRE. COORDINATE REMOVAL OF PROTECTIVE BARRIERS WITH CINEMARK PROJECT MANAGER TO ALLOW FOR FINISH WORK ADJACENT TO SCREEN. NO DRY WALL, CONCRETE, OR OTHER DUST GENERATING WORK AFTER REMOVAL. REUSE EXISTING DRAPERY NAILER.

20 27 31 32 39 70 EQ TYP. EQ TYP. 74

PERMIT SET 10.01.2012Revision Schedule Rev Rev Rev # Date Description

ZZA G ZZA

EQ TYP.

ZK

M

AUDITORIUM A A130

15 7 12'-0" 27 94 94

EQ TYP.

ZK

ZC

74

118

39

ZK ZX ZX

R

ZZP 12'-0" 32

74

AUDITORIUM A A130 291 SEATS INCL 5 WHC70 7 32 70 31 TYP. 15

118

G

L

PROMENADE A129

ZW

AUD. A - EXISTING SIDE WALL ELEVATION 'B' (AUD. P SIM) 6 1/8" = 1'-0"

AUD. A - PROPOSED SIDE WALL ELEVATION 'B' (AUD. P SIM) 2 1/8" = 1'-0"City of Aurora Building Division

Reviewed for Code Compliance Approved as Noted: Richard LaCoste Date: Oct 05, 20122006 INTERNATIONAL CODES & 2008 NEC

PROJECT # 12057

ZZA

NEW WALL AND BLOCKING FOR RAIL AND WOOD CAP. NEW STUDS TO BE CONNECTED TO EXISTING TO FORM CONTINUOUS WALL MAINTAIN 1 1/2" CLEARANCE FROM RAIL TO WOOD CAP

R ZX ZP

ZK ZX G

15

7 3'-0" L 3'-7" B2 32 A

EQ

AUDITORIUM A A130 291 SEATS INCL 5 WHC

31 70

EQ

7 15 12'-0"

TYP. 70

12'-0"

ZG

M

AUDITORIUM A A130

27

EQ

ZK

G

94

74

EQ

ZC

ZZX

ZK

ZZA

39

118

683943 RSN: XXXXXX Permit #: 12-626423 YYYY-ZZZZZZ-AA74 32

ENLARGED ELEVATIONS AUDITORIUMS A &B

SHEET NUMBER

A

TYPICAL EXTENDED CROSS OVER WALL ELEVATION 9 1/4" = 1'-0"

AUD. A - EXISTING SIDE WALL ELEVATION 'A' (AUD. P SIM) 5 1/8" = 1'-0"

AUD. A PROPOSED SIDE ELEVATION "A" (AUD. P SIM) 1 1/8" = 1'-0"

A3.61

AURORA, CO CUSA #428

EQ TYP.

SINGLE SIDE APPROACH WHEELCHAIR SPACE TO HAVE CLEAR FLOOR SPACE OF 36"x60" MIN. SINGLE WHEELCHAIR SPACE TO HAVE CLEAR FLOOR SPACE OF 36"x48" MIN. DOUBLE WHEELCHAIR SPACE TO HAVE CLEAR FLOOR SPACE OF 66"x48" MIN. EVERY WHEELCHAIR SPACE MUST HAVE A COMPANION SEAT CONFIRM WITH OWNER PRIOR TO REMOVAL ANY FINISHES PROTECT ALL FINISHES FROM DAMAGE REMOVED MATERIALS/FINISHES TO BE RECYCLED WHEN POSSIBLE INCLUDING CARPET, CEILING TILES, WALL COVERINGS AND METALS MINIMUM RISER HEIGHT 4" (STAIRS) MINIMUM TREAD DEPTH 12" (STAIRS) MINIMUM SEAT BACK HEIGHT: 44" EXISTING CONDITION DIMENSIONS ARE FROM FACE OF GYP. PROPOSED DIMENSIONS ARE FROM FACE OF EXISTING FINISH

NEW WALL ZZA ZZ ZZA 1'-2" M ZY ZZX ZY ZC 27 74 72 1'-2" 118 74 39 NEW DOOR 3D 2/A1 G ZZP 94 15 TYP.

EXISTING ELEVATION TO REMAIN PROPOSED ELEVATION

EXISTING DOOR TO REMAIN

a r c h i t e c t sINTERNATIONAL

TK

90

CALLOUT OF 3D VIEW EXISTING AUDITORIUM CARPET TO REMAIN

Keynote Legend - DEMO 7 A D ZW MAINTAIN EXISTING DOOR. SEATS REMOVED BY OWNER GRIND ANCHORS FLUSH AND PATCH CONCRETE AS DIRECTED-RE: GENERAL NOTES E EXISTING PROJECTION EQUIPMENT TO BE REMOVED BY OWNER FOR REUSE G REMOVE EXISTING 1X4 DRAPERY TRIM TO ALLOW FOR NEW DRAPERY AND REINSTALLATION. PAINT EXISTING AND NEW TRIM BLACK. K EXISTING LOW WALL TO REMAIN L REMOVE EXISTING HANDRAIL. M REMOVE ALL SIDEWALL FINISHES. PROTECT SPEAKER WIRES AND INSULATION FROM DAMAGE DURING WORK. ANY DAMAGE TO SPEAKER WIRING WILL BE REPLACED BY GC TO SOURCE. N REMOVE/REWORK EXISTING RISER PLATFORM. RE: STRUCT O REMOVE EXISTING FLOOR FINISH R REMOVE EXISTING WALL SCONCES. REMOVE CONDUIT AND CAP ELECTRICAL. PROVIDE SCONCES TO OWNER U DEMOLISH PORTION OF FLOOR TO ALLOW FOR NEW RAMPING. ZA DEMO/REWORK CONCRETE STAIR TO ALLOW FOR NEW WORK. RE STRUCTURAL. ZC EXISTING CEILING TO REMAIN. ZG REMOVE EXISTING SCREEN AND FRAME, DEMO ALL CONNECTIONS AND REPAIR ALL SURFACES TO BE SMOOTH AND FLUSH FOR NEW WORK ZI TEMPORARILY REMOVE WOOD CAP FOR NEW FINISHES AND NEW WORK. (BOTH SIDES OF WALL) ZK DEMOLISH EXISTING WALL SCONCES AND TEMPORARILY CAP POWER AS REQUIRED AND PREP WALL FOR NEW SCONCE. RE: MEP ZR PROTECT AND MAINTAIN EXISTING CARPET TO REMAIN. ZW DEMOLISH PORTION OF FLOOR TO ALLOW FOR NEW WORK. RE STURCTURAL. ZX GC TO REMOVE EXISTING SURROUND SPEAKER AND SAVE FOR REINSTALLATION. TEMPORARILY CAP ELECTRICAL AND PROTECT FROM DAMAGE AND CONSTRUCTION DUST PARTICLES.PROTECT BRACKET, MOUNTING, AND BLOCKING FOR REUSE IN REINSTALLATION. ZY EXISTING HANDRAIL TO REMAIN IN PLACE. PROTECT DURING CONSTRUCTION. SAND TO REMOVE FINISH AND PREPARE TO BE PAINTED. ZZ EXISTING PORT WINDOW TO REMAIN. ZZA GC TO REMOVE EXISTING SURROUND SPEAKER AND BRACKET. SAVE FOR REINSTALLATION IN NEW LOCATION.PROTECT WIRING AND INSULATION. ZZP EXISTING SCREEN & FRAME TO REMAIN. G.C. TO PROVIDE HEAVY DUTY SHEET PLASTIC PROTECTION 1" IN FRONT OF SCREEN & SECURE TO WALLS, FLOORS, AND CEILING. ANY DAMAGES TO WALLS, FLOORS AND CEILING BY G.C. FROM SECURING PROTECTIVE PLASTIC WILL BE REPAIRED BY G.C. ANY DUCTWORK OR RETURNS BEHIND PROTECTIVE PLASTIC TO BE FULLY SEALED PRIOR TO START OF DEMOLITION OR CONSTRUCTION. FAILURE TO PROTECT SCREENS, FRAME OR SPEAKERS FROM AIRBORNE DUST WILL RESULT IN REPLACEMENT OF SCREEN OR COMPONENT BY G.C. ZZX EXISTING DRAPERY NAILER TO BE SALVAGED AND REUSED FOR INSTALLATION OF NEW DRAPERY

106 West 11th Street Suite 1900 Kansas City, Missouri 64105 Phone : 816-842-7552 Fax : 816-842-1302DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT

AUD. B EXISTING REAR WALL ELEVATION (AUD O SIM) 13 1/8" = 1'-0"

AUD. B EXISTING SCREEN WALL ELEVATION (AUD. O SIM) 9 1/8" = 1'-0"

AUD. B PROPSED REAR WALL ELEVATION (AUD O SIM) 5 1/8" = 1'-0"

AUD. B PROPOSED SCREEN WALL ELEVATION (AUD. O SIM) 4 1/8" = 1'-0"

1'-2" ZZX ZK Mezzanine 118' - 3" EXTEND WALL TO 3'-6" TO MATCH RAKE OF NEW STEPS, TIE INTO EXISTING WALL LOW WALL POST TYP. SEE DETAIL 5/A3.74 R ZG G ZX ZX ZY 32 15 14 32 WC-3 TYP. M ZC ZZA ZX ZY ZY ALIGN G 69 27 31 118 D-1 70 TYP. 20 TYP. 73 15

First Floor 100' - 0"

AUDITORIUM B LOW WALL EXTENSION (AUD. O SIM.) 12 3/32" = 1'-0"

ZW

8

AUD. B SECTION EXISTING 1/8" = 1'-0"

3

AUD. B SECTION PROPOSED 1/8" = 1'-0"

Keynote Legend - NEW K ZW 12 A3.62 L ZR E ZI O ZY TYP. 45 1'-0" TYP. 136 12 A3.62 TYP. 11 B2 1'-0" MIN. 3'-0" CLR. 11 R3C R3C R3C 73 73 12 14 7 10 11 NEW HANDRAIL REF: RAIL KEY. OVERPOUR NEW SLOPE/RAMP AND LANDINGS LOW WALL TO BE EXTENDED TO 3'-6" A.F.F. (36" AT CROSSOVER WALL) INSTALL NEW WALL CARPET AND WOOD CAP. FOLLOW RAKE OF STAIRS AND LANDINGS. WALL CARPET TO WRAP TOP OF WALL BY 2" EACH SIDE PRIOR TO INSTALL OF WOOD CAP. REWORK/OVERPOUR NEW SEATING PLATFORM AND AISLE STAIRS NEW SEATS INSTALLED BY OWNER, VERIFY