  • CentrifugalChiller High EfficiencyGFG-S/SIT Series

    GXG-S/SIT SeriesGSG-S/SIT Series

    G700DLV

    Printed in Japan (H) MR-E070P Mar. 2017

    http://www.jci-hitachi.com

  • High-efficiency CompressorIncreased compressor efficiency

    3 dimensional blade impeller (2 stages)

    Optimally designed diffuser with vane

    Low rotating speed compressor enables the use of low-loss bearing structure.

    Semi-hermetic design

    Hitachi High Efficiency Centrifugal Chillers realize world top-level high efficiency and downsizing thanks to the advanced technologies to optimize the design of compressors and heat-exchangers. Several series of product lineup and flexible model selection satisfy huge variety of customers’ demand such as energy saving, space saving, etc. In addition, Hitachi’s unique technologies accumulated through over 80-year history ensure long term stable operation.

    Centrifugal Chiller

    Advantages

    Our Key Technologies Realizing High-Efficiency.

    Excellent Energy-Saving EffectFirst class efficiency greatly contributes energy saving of users.

    Compact DesignSignificantly compact and light weight design enables space saving and easy replacement.

    High ReliabilityHitachi’s unique technologies enhance high reliability and long term stable operation.

    Global Warming PreventionEnergy saving by high-efficiency centrifugal chillers

    Global warming refers to the phenomenon of global rising in average atmospheric temperatures due to increased volume of CO2 and methane as a result of burning fossil fuels such as petroleum and coal. The 1995 IPCC* Report predicted that if the emission of CO2, etc. continued as it was, the atmospheric temperature would rise by as much as 2˚C by the end of the 21st century and, as a result, the sea level would rise by approximately 50 cm from the present level. In such circumstances, it is even more important to save the energy consumed by air conditioners in order to cut CO2 emission. * IPCC: Intergovernmental Panel on Climate Change

    High-efficiency Refrigerant CycleIncreased refrigerating cycle efficiency

    2 stages compression cycle with economizer

    High-performance Heat ExchangerIncreased efficiency resulted from improved

    performance of heat exchanger

    Employment of high-performance heat exchange tubes.

    Optimal structural design of heat exchanger to match

    the behavior of refrigerant.

    Featuring Ozone-safe

    HFC134a

    Max. COP7.0

    Achieved

    High Efficiency Centrifugal Chiller ■ HC-F-GFG-SSC Series (Super High Efficiency Type) ■ HC-F-GXG-S Series (High Efficiency Type) ■ HC-F-GSG-S Series (Compact Type) 1,055~7,032kW (300~2,000USRT)

    High Efficiency Inverter Controlled Centrifugal Chiller ■ HC-F-GFG-SITSC Series (Super High Efficiency Type) ■ HC-F-GXG-SIT Series (High Efficiency Type) ■ HC-F-GSG-SIT Series (Compact Type) 1,055~4,922kW (300~1,400USRT)

    *Capacity can be extended up to max. 2,500USRT with single compressor.

    1 2

  • High-efficiency CompressorIncreased compressor efficiency

    3 dimensional blade impeller (2 stages)

    Optimally designed diffuser with vane

    Low rotating speed compressor enables the use of low-loss bearing structure.

    Semi-hermetic design

    Hitachi High Efficiency Centrifugal Chillers realize world top-level high efficiency and downsizing thanks to the advanced technologies to optimize the design of compressors and heat-exchangers. Several series of product lineup and flexible model selection satisfy huge variety of customers’ demand such as energy saving, space saving, etc. In addition, Hitachi’s unique technologies accumulated through over 80-year history ensure long term stable operation.

    Centrifugal Chiller

    Advantages

    Our Key Technologies Realizing High-Efficiency.

    Excellent Energy-Saving EffectFirst class efficiency greatly contributes energy saving of users.

    Compact DesignSignificantly compact and light weight design enables space saving and easy replacement.

    High ReliabilityHitachi’s unique technologies enhance high reliability and long term stable operation.

    Global Warming PreventionEnergy saving by high-efficiency centrifugal chillers

    Global warming refers to the phenomenon of global rising in average atmospheric temperatures due to increased volume of CO2 and methane as a result of burning fossil fuels such as petroleum and coal. The 1995 IPCC* Report predicted that if the emission of CO2, etc. continued as it was, the atmospheric temperature would rise by as much as 2˚C by the end of the 21st century and, as a result, the sea level would rise by approximately 50 cm from the present level. In such circumstances, it is even more important to save the energy consumed by air conditioners in order to cut CO2 emission. * IPCC: Intergovernmental Panel on Climate Change

    High-efficiency Refrigerant CycleIncreased refrigerating cycle efficiency

    2 stages compression cycle with economizer

    High-performance Heat ExchangerIncreased efficiency resulted from improved

    performance of heat exchanger

    Employment of high-performance heat exchange tubes.

    Optimal structural design of heat exchanger to match

    the behavior of refrigerant.

    Featuring Ozone-safe

    HFC134a

    Max. COP7.0

    Achieved

    High Efficiency Centrifugal Chiller ■ HC-F-GFG-SSC Series (Super High Efficiency Type) ■ HC-F-GXG-S Series (High Efficiency Type) ■ HC-F-GSG-S Series (Compact Type) 1,055~7,032kW (300~2,000USRT)

    High Efficiency Inverter Controlled Centrifugal Chiller ■ HC-F-GFG-SITSC Series (Super High Efficiency Type) ■ HC-F-GXG-SIT Series (High Efficiency Type) ■ HC-F-GSG-SIT Series (Compact Type) 1,055~4,922kW (300~1,400USRT)

    *Capacity can be extended up to max. 2,500USRT with single compressor.

    1 2

  • 3 4

    Advantages

    ● Lubrication Oil Supplying System

    Lubricating oil

    Oil strainer

    Oil cooler (Cooled by the refrigerant)

    Oil heater

    Oil pump Bearing

    Refrigerant liquid from the condenser

    Refrigerant gas to the evaporator

    Oil tank

    for the prevention of dissolving refrigerant into the oil when the machine stops.

    Cool

    ing

    capa

    city

    (%)

    Alarm

    30 32 34

    50

    100

    OperatingRangeIncrease

    Rated point

    Cooling water inlet temperature (ºC)

    Before stopping due to “High Pressure Cut”, an alarm signals to activate the pressure limit control prevention control function to continue operation.

    Top-class Compact Design and Light Weight Design The compact design greatly improves flexibility in installation. Realizing space saving of machine room. Easy carry-in to machine room. Suitable for replacement of long-operating chillers. Significant reduction of refrigerant volume.

    New Type EconomizerImprovement of vapor-liquid separation performance and significant downsizing are realized by the use of Newly-developed economizer. (cyclonic system)

    Easy Operation with Touch Panel Type Control Panel 10.4 inch color touch panel screen Monitor various operating data Indicate trend graph during operation Trend data for max. 40 hours. (Updated every 1 hour) Indicate and store operation history for the past 12 hours (Updated every hour) Indicate and store failure and alarm history (latest 6 times each) Show Handling Guide in case of failure Automatic restart function after instantaneous power failure (Option) Multilingual Languages Indication (Japanese, English, Chinese [Simplified, Traditional], Portuguese) Download 3-month operation date to USB memory

    Conventional Model GXG-S Series

    GXG-S Series

    Conventional Model

    GXG-S Series

    Conventional Model

    GXG-S Series

    Conventional Model

    2-stage Compression CycleTo improve compressor efficiency, refrigerant economizer is added with 2-stage compressor equipped with 2 impellers, as shown in the drawing below. In this case, the refrigerant goes through two expansion devices. When the refrigerant goes through the first device, some of the refrigerant flashes, or become a gas. The flashed refrigerant is introduced to the compressor between the two stages. In the one-stage compressor cycle without the econo-mizer, all refrigerant flows in the cycle. Comparatively, in the 2-stage compressor cycle the part of the refrigerant is bypassed from the economizer to the 2-stage impeller.

    ● 2-stage Centrifugal Chiller Cycle

    ● Comparison of Chiller Size (Comparison of 1000RT models)

    Installation Space Operating Weight Refrigerant Volume

    Two-phase refrigerant

    Refrigerant gas

    Refrigerant liquid

    500031504550

    2400

    100%69%

    100% 100%

    58% 53%

    Approx.31%Reduction

    Approx.42%Reduction Approx.47%

    Reduction

    Approx.31%Reduction

    Approx.42%Reduction Approx.47%

    Reduction

    Com

    pres

    sor

    com

    pres

    sion

    rat

    io

    ● Compressor characteristic comparison

    Flowrate (cooling capacity)

    ARI temp. condition chillerHitachi

    JIS cooling water temp. standard

    ARI cooling water temperature standard

    * Surging phenomenon tends to occur for ARI temperature condition chillers

    Load100%75%50%25%0%

    JIS32˚C

    30.75˚C29.5˚C28.25˚C

    27˚C

    ARI29.4˚C23.9˚C18.3˚C18.3˚C18.3˚C

    Surging margin

    * This figure shows general characteristics and does not provide any guarantees as to the performance.

    Surging

    Operation screen Trend data screen

    Failure screen Handling guide screen

    Compatible with BMSChiller control panel is equipped with RS485 communication port and compatible with Building Management System through MODBUS RTU protocol.

    Quick automatic restart after power failure.Chiller automatically starts up after instantaneous power failure (less than 10 sec.) and reverts to normal operation in shortest period.

    ● Min. cooling water temperature 12˚C (GFG/GXG), and 15˚C (GSG)● Thermal insulation ● Spring isolator● Max. working pressure up to 2.5Mpa● Ball type automatic tube cleaning system for chilled & cooling water● Chilled & cooling water variable flow control● Marine type water box / Hinged type water box● Min. cooling capacity 10% (with hot gas bypass)● Large temperature difference (to reduce the water flow rate)● Delivery in knockdown form (4 pieces-compressor, heat exchangers, economizer, control panel, 5 pieces-evaporator & condenser is also separated.)● Soft starter (for low voltage)

    High Reliability Lubrication SystemDirect refrigerant cooling of lubrication oil in oil cooler without cooling water piping increases reliability.

    Surge ProtectionAdopting strict criteria specified in JIS for stable operation under high cooling water temperature. 3D 2-stage impeller enables stable operation even at low cooling load or high cooling water inlet temp. which prevents occurrence of surge.

    Wider Operating RangeStable operation continues even when rise of condenser pressure due to cooling water temperature in hot summer and/ or proceeding of tube fouling.

    Other Unique Feature to Enhance Reliability● Key-free impeller coupling system● Accurate chilled water temperature control within ±0.2˚C● Low noise and longer bearing life due to lower rotation speed of 2-stage compression cycle.

    ● Continuous oil recovery with automatic refrigerant cleaner● Prevention of oil degradation by removing residual water with filter dryer

    Operational Item & Function

    ● Example of rising cooling water temperature due to rising ambient temperature

    CompressorPower source

    Condenser

    Coolingwater

    Orifice

    Low press.low temp.suction gas

    High press.high temp.discharge gas

    Evaporator

    Chilled water

    EconomizerEconomizer

  • 3 4

    Advantages

    ● Lubrication Oil Supplying System

    Lubricating oil

    Oil strainer

    Oil cooler (Cooled by the refrigerant)

    Oil heater

    Oil pump Bearing

    Refrigerant liquid from the condenser

    Refrigerant gas to the evaporator

    Oil tank

    for the prevention of dissolving refrigerant into the oil when the machine stops.

    Cool

    ing

    capa

    city

    (%)

    Alarm

    30 32 34

    50

    100

    OperatingRangeIncrease

    Rated point

    Cooling water inlet temperature (ºC)

    Before stopping due to “High Pressure Cut”, an alarm signals to activate the pressure limit control prevention control function to continue operation.

    Top-class Compact Design and Light Weight Design The compact design greatly improves flexibility in installation. Realizing space saving of machine room. Easy carry-in to machine room. Suitable for replacement of long-operating chillers. Significant reduction of refrigerant volume.

    New Type EconomizerImprovement of vapor-liquid separation performance and significant downsizing are realized by the use of Newly-developed economizer. (cyclonic system)

    Easy Operation with Touch Panel Type Control Panel 10.4 inch color touch panel screen Monitor various operating data Indicate trend graph during operation Trend data for max. 40 hours. (Updated every 1 hour) Indicate and store operation history for the past 12 hours (Updated every hour) Indicate and store failure and alarm history (latest 6 times each) Show Handling Guide in case of failure Automatic restart function after instantaneous power failure (Option) Multilingual Languages Indication (Japanese, English, Chinese [Simplified, Traditional], Portuguese) Download 3-month operation date to USB memory

    Conventional Model GXG-S Series

    GXG-S Series

    Conventional Model

    GXG-S Series

    Conventional Model

    GXG-S Series

    Conventional Model

    2-stage Compression CycleTo improve compressor efficiency, refrigerant economizer is added with 2-stage compressor equipped with 2 impellers, as shown in the drawing below. In this case, the refrigerant goes through two expansion devices. When the refrigerant goes through the first device, some of the refrigerant flashes, or become a gas. The flashed refrigerant is introduced to the compressor between the two stages. In the one-stage compressor cycle without the econo-mizer, all refrigerant flows in the cycle. Comparatively, in the 2-stage compressor cycle the part of the refrigerant is bypassed from the economizer to the 2-stage impeller.

    ● 2-stage Centrifugal Chiller Cycle

    ● Comparison of Chiller Size (Comparison of 1000RT models)

    Installation Space Operating Weight Refrigerant Volume

    Two-phase refrigerant

    Refrigerant gas

    Refrigerant liquid

    500031504550

    2400

    100%69%

    100% 100%

    58% 53%

    Approx.31%Reduction

    Approx.42%Reduction Approx.47%

    Reduction

    Approx.31%Reduction

    Approx.42%Reduction Approx.47%

    Reduction

    Com

    pres

    sor

    com

    pres

    sion

    rat

    io

    ● Compressor characteristic comparison

    Flowrate (cooling capacity)

    ARI temp. condition chillerHitachi

    JIS cooling water temp. standard

    ARI cooling water temperature standard

    * Surging phenomenon tends to occur for ARI temperature condition chillers

    Load100%75%50%25%0%

    JIS32˚C

    30.75˚C29.5˚C28.25˚C

    27˚C

    ARI29.4˚C23.9˚C18.3˚C18.3˚C18.3˚C

    Surging margin

    * This figure shows general characteristics and does not provide any guarantees as to the performance.

    Surging

    Operation screen Trend data screen

    Failure screen Handling guide screen

    Compatible with BMSChiller control panel is equipped with RS485 communication port and compatible with Building Management System through MODBUS RTU protocol.

    Quick automatic restart after power failure.Chiller automatically starts up after instantaneous power failure (less than 10 sec.) and reverts to normal operation in shortest period.

    ● Min. cooling water temperature 12˚C (GFG/GXG), and 15˚C (GSG)● Thermal insulation ● Spring isolator● Max. working pressure up to 2.5Mpa● Ball type automatic tube cleaning system for chilled & cooling water● Chilled & cooling water variable flow control● Marine type water box / Hinged type water box● Min. cooling capacity 10% (with hot gas bypass)● Large temperature difference (to reduce the water flow rate)● Delivery in knockdown form (4 pieces-compressor, heat exchangers, economizer, control panel, 5 pieces-evaporator & condenser is also separated.)● Soft starter (for low voltage)

    High Reliability Lubrication SystemDirect refrigerant cooling of lubrication oil in oil cooler without cooling water piping increases reliability.

    Surge ProtectionAdopting strict criteria specified in JIS for stable operation under high cooling water temperature. 3D 2-stage impeller enables stable operation even at low cooling load or high cooling water inlet temp. which prevents occurrence of surge.

    Wider Operating RangeStable operation continues even when rise of condenser pressure due to cooling water temperature in hot summer and/ or proceeding of tube fouling.

    Other Unique Feature to Enhance Reliability● Key-free impeller coupling system● Accurate chilled water temperature control within ±0.2˚C● Low noise and longer bearing life due to lower rotation speed of 2-stage compression cycle.● Continuous oil recovery with automatic refrigerant cleaner● Prevention of oil degradation by removing residual water with filter dryer

    Operational Item & Function

    ● Example of rising cooling water temperature due to rising ambient temperature

    CompressorPower source

    Condenser

    Coolingwater

    Orifice

    Low press.low temp.suction gas

    High press.high temp.discharge gas

    Evaporator

    Chilled water

    EconomizerEconomizer

  • COP during winter season is improved to maximum 330%.GFG-SIT/GXG-SIT/GSG-SIT Series can be operated stably even in the very low cooling water temperature. In accordance with the cooling water temperature by seasons, the chillers can maintain highly efficient operation with variable speed control of compressor. Therefore, the chillers are recommended for the customers who need the cooling operation throughout the year.

    ● COP Characteristics throughout the year

    Excellent COP at Partial LoadVarious technologies such as newly developed high efficiency econo-mizer (cyclonic system), etc. enabled drastic improvement of the efficiency at partial load with low cooling water temperature.Improvement of the oil supply temperature control and the automatic oil recovery enables extension of the motor speed control range at low cooling water inlet temperature.

    Max. Partial Load

    COP 22.4IPLV 11.5

    Excellent Efficiency throughout the Year

    High Efficiency2-stage Compressor

    Cool

    ing

    Wat

    er In

    let

    Tem

    p. (˚

    C)

    Cooling Capacity (%)

    35

    30

    25

    20

    15

    1020 40 60 80 100

    Motor SpeedControl+ Vane Control

    Motor SpeedControl

    Extension ofControl Range

    Efficiency is improved by minimizing usage of vane control

    25

    20

    15

    10

    5

    01 2 3 4 5 6 7 8 9 10 11 12

    10

    20

    30

    COP

    Month

    Cool

    ing

    Wat

    er In

    let

    Tem

    p. (˚

    C)

    Cooling Water Temp.

    Inverter Control System

    Constant Speed SystemCOP approx.330%

    High EfficiencyHeat Exchangers

    “Energy Saving Mode” Operation (Peak Cut Operation) (option)

    Once the target motor power consumption is set, the chiller is automati-cally controlled by the motor speed, the inlet guide vane opening and the chilled water outlet tempera-ture rise. This control is extremely useful for the energy saving especially in the off-peak season when the motor speed is easily decreased.

    “Eco Mode” Operation (Chilled Water Inlet Temp. Control)The chiller is usually controlled so the chilled water outlet temperature to be constant. This "Eco Mode" operation introduces the inlet temperature control, where the chilled water inlet temperature is controlled to be constant. The outlet temperature rises a bit but this is enough for the off-peak season air conditioning.

    Cooling Water Variable Flow Operation (option)

    When the cooling water variable flow control is applied, the cooling water flow rate is automatically calculated so the total power consumption of the compressor motor and the cooling water pump motor becomes minimum.

    Hermonic Filter (option)

    Harmonic filter is available to comply the requirement of IEEE 519.

    ● Comparison of Characteristics between CHW Outlet/Inlet Temp. Control

    ● Energy Saving Mode Setting Screen

    ● Characteristics of Cooling Water Variable Flow Operation

    20 40 60 80 100

    25

    20

    15

    10

    5

    0

    COP

    Cooling Capacity (%)

    CW InletTemp.

    16˚C

    20˚C

    24˚C

    28˚C

    COP is improved drastically when cooling load decreases.

    COP : approx. 40% Increase

    CHW Inlet Temp. ControlCHW Outlet Temp. Control

    Energy & Power Saving Operation Functions

    Low

    Low

    Cooling Water flow High

    High Minimum Power Consumption

    Total Power Consumption(Centrifugal chiller + Cooling Water Pump)

    Power Consumption of Centrifugal Chiller

    Power Consumption of Cooling Water Pump

    PowerConsumption

    *GFG-SITSC model

    Improvement of the Oil Supply Temperature ControlWhen the compressor rotation speed is low, the friction heat generated at bearings decreases. Therefore, refrigerant flow to oil cooler is controlled to keep the oil temperature property.

    Lubricating oil

    Oil strainerOil cooler (Cooled by the refrigerant)

    Oil heater

    Oil pump

    Bearing

    Refrigerant liquid from the condenser

    Electric Valve to Control Oil Temp.

    Refrigerant gas to the evaporator

    Oil tank

    M

    25

    20

    15

    10

    5

    020 40 60 80 100

    COP

    Cooling Capacity (%)

    12˚C

    CW InletTemp.

    16˚C

    20˚C24˚C28˚C

    Max. Partial Load

    COP 22.4COP is improved by theReduction of Motor Speed

    1

    Hitachi High Efficiency Inverter Controlled Centrifugal Chiller

    Advantages

    Hitachi High Efficiency Inverter-controlled Centrifugal Chillers realize energy-saving operation through out the year utilizing variable motor speed control with inverter unit, drastically improving partial load efficiency under low cooling water temperature

    condition in off-peak seasons. In addition, the chillers have many unique energy saving functions which satisfy the demand to minimize the energy consump-tion.

    5 6

  • COP during winter season is improved to maximum 330%.GFG-SIT/GXG-SIT/GSG-SIT Series can be operated stably even in the very low cooling water temperature. In accordance with the cooling water temperature by seasons, the chillers can maintain highly efficient operation with variable speed control of compressor. Therefore, the chillers are recommended for the customers who need the cooling operation throughout the year.

    ● COP Characteristics throughout the year

    Excellent COP at Partial LoadVarious technologies such as newly developed high efficiency econo-mizer (cyclonic system), etc. enabled drastic improvement of the efficiency at partial load with low cooling water temperature.Improvement of the oil supply temperature control and the automatic oil recovery enables extension of the motor speed control range at low cooling water inlet temperature.

    Max. Partial Load

    COP 22.4IPLV 11.5

    Excellent Efficiency throughout the Year

    High Efficiency2-stage Compressor

    Cool

    ing

    Wat

    er In

    let

    Tem

    p. (˚

    C)

    Cooling Capacity (%)

    35

    30

    25

    20

    15

    1020 40 60 80 100

    Motor SpeedControl+ Vane Control

    Motor SpeedControl

    Extension ofControl Range

    Efficiency is improved by minimizing usage of vane control

    25

    20

    15

    10

    5

    01 2 3 4 5 6 7 8 9 10 11 12

    10

    20

    30

    COP

    Month

    Cool

    ing

    Wat

    er In

    let

    Tem

    p. (˚

    C)

    Cooling Water Temp.

    Inverter Control System

    Constant Speed SystemCOP approx.330%

    High EfficiencyHeat Exchangers

    “Energy Saving Mode” Operation (Peak Cut Operation) (option)

    Once the target motor power consumption is set, the chiller is automati-cally controlled by the motor speed, the inlet guide vane opening and the chilled water outlet tempera-ture rise. This control is extremely useful for the energy saving especially in the off-peak season when the motor speed is easily decreased.

    “Eco Mode” Operation (Chilled Water Inlet Temp. Control)The chiller is usually controlled so the chilled water outlet temperature to be constant. This "Eco Mode" operation introduces the inlet temperature control, where the chilled water inlet temperature is controlled to be constant. The outlet temperature rises a bit but this is enough for the off-peak season air conditioning.

    Cooling Water Variable Flow Operation (option)

    When the cooling water variable flow control is applied, the cooling water flow rate is automatically calculated so the total power consumption of the compressor motor and the cooling water pump motor becomes minimum.

    Hermonic Filter (option)

    Harmonic filter is available to comply the requirement of IEEE 519.

    ● Comparison of Characteristics between CHW Outlet/Inlet Temp. Control

    ● Energy Saving Mode Setting Screen

    ● Characteristics of Cooling Water Variable Flow Operation

    20 40 60 80 100

    25

    20

    15

    10

    5

    0

    COP

    Cooling Capacity (%)

    CW InletTemp.

    16˚C

    20˚C

    24˚C

    28˚C

    COP is improved drastically when cooling load decreases.

    COP : approx. 40% Increase

    CHW Inlet Temp. ControlCHW Outlet Temp. Control

    Energy & Power Saving Operation Functions

    Low

    Low

    Cooling Water flow High

    High Minimum Power Consumption

    Total Power Consumption(Centrifugal chiller + Cooling Water Pump)

    Power Consumption of Centrifugal Chiller

    Power Consumption of Cooling Water Pump

    PowerConsumption

    *GFG-SITSC model

    Improvement of the Oil Supply Temperature ControlWhen the compressor rotation speed is low, the friction heat generated at bearings decreases. Therefore, refrigerant flow to oil cooler is controlled to keep the oil temperature property.

    Lubricating oil

    Oil strainerOil cooler (Cooled by the refrigerant)

    Oil heater

    Oil pump

    Bearing

    Refrigerant liquid from the condenser

    Electric Valve to Control Oil Temp.

    Refrigerant gas to the evaporator

    Oil tank

    M

    25

    20

    15

    10

    5

    020 40 60 80 100

    COP

    Cooling Capacity (%)

    12˚C

    CW InletTemp.

    16˚C

    20˚C24˚C28˚C

    Max. Partial Load

    COP 22.4COP is improved by theReduction of Motor Speed

    1

    Hitachi High Efficiency Inverter Controlled Centrifugal Chiller

    Advantages

    Hitachi High Efficiency Inverter-controlled Centrifugal Chillers realize energy-saving operation through out the year utilizing variable motor speed control with inverter unit, drastically improving partial load efficiency under low cooling water temperature

    condition in off-peak seasons. In addition, the chillers have many unique energy saving functions which satisfy the demand to minimize the energy consump-tion.

    5 6

  • 7 8

    Model

    5.15 - 6.16 5.15 - 6.16 5.35 - 6.40 5.36 - 6.415.58 - 6.68 5.62 - 6.72 5.70 - 6.82 5.63 - 6.73 5.59 - 6.69 5.65 - 6.75 5.74 - 6.86 5.59 - 6.69 5.65 - 6.75 5.66 - 6.77 5.81 - 6.94 5.74 - 6.86 5.78 - 6.91 5.79 - 6.92 5.83 - 6.97 5.84 - 6.99 5.85 - 7.00 5.86 - 7.01 5.89 - 7.04 5.74 - 6.86 5.77 - 6.90 5.69 - 6.81 5.73 - 6.85 5.77 - 6.90 5.84 - 6.99

    3,5503,5503,5503,5504,0504,0504,0504,0504,0504,0504,0504,0504,0504,0504,5504,5504,5504,5504,5504,5504,5504,5504,5504,8504,8505,2505,2505,2505,250

    1,6501,6501,9001,9001,9002,0002,0002,0002,2502,2502,2502,2502,4002,4002,4002,4002,4002,6002,6002,6002,6002,6002,6003,3003,3003,5003,5003,5003,500

    2,2002,2002,4002,4002,4502,4502,4502,4502,6502,6502,6502,8002,8002,8002,8002,8002,8002,9002,9002,9002,9002,9002,9003,4003,4003,7003,7003,7003,700

    3,0003,0003,0003,0003,5003,5003,5003,5003,5003,5003,5003,5003,5003,5004,0004,0004,0004,0004,0004,0004,0004,0004,0004,0004,0004,5004,5004,5004,500

    5,8005,8007,0007,0008,4008,7008,9009,10010,70010,70011,10011,10012,40012,40013,90014,10014,30014,80015,80015,80015,80016,00016,00020,50020,70023,70024,00024,20024,500

    7,0007,1008,5008,6009,90010,40010,50010,90012,60012,70013,30013,40014,80014,90016,90017,20017,50018,10019,10019,20019,30019,60019,70024,30024,60027,50027,90028,20028,500

    COPHeight (C)Width (B)Length (A)

    Overall Dimension mm

    ■ HC-F_GXG-S

    REMARKS1. Please consult with our sales staff or distributor for actual specifications for cooling  capacity, expected kW input and COP, depending on selected operating parameters. 2. The above specifications are subject to change without notice for technical improvements.  * This table is applicable to chillers to be manufactured for normal water.3. Capacity control range is 100% to approx. 20%.  (Minimum cooling capacity can be reduced to 10% as option.) 4. Fouling factor is assumed to be 0.018m2K/kW for chilled water and 0.044m2K/kW for  cooling water. 5. Standard main power source : 380V/400V/415V/440V/460V (up to HC-F1400GXG-S),  3000V/3300V/6000V/6600V (any capacity, only constant speed),  10000V/11000V (F900GXG-S and above, only constant speed), AC, 50/60Hz, 3ph. 6. Auxiliary power: AC 380V/50Hz/3φ/3W or 4W.7. Maximum working pressure is 1.0MPa for both chilled and cooling water. If higher maximum  working pressure is required, please specify at inquiry. (Up to 2.5 MPa is available.)

    HC-F300GXG-SHC-F350GXG-SHC-F400GXG-SHC-F450GXG-SHC-F500GXG-SHC-F550GXG-SHC-F600GXG-SHC-F650GXG-SHC-F700GXG-SHC-F750GXG-SHC-F800GXG-SHC-F850GXG-SHC-F900GXG-SHC-F950GXG-SHC-F1000GXG-SHC-F1050GXG-SHC-F1100GXG-SHC-F1150GXG-SHC-F1200GXG-SHC-F1250GXG-SHC-F1300GXG-SHC-F1350GXG-SHC-F1400GXG-S

    HC-F1500GXG-S (*1)HC-F1600GXG-S (*1)HC-F1700GXG-S (*1)HC-F1800GXG-S (*1)HC-F1900GXG-S (*1)HC-F2000GXG-S (*1)

    300 - 349350 - 350351 - 449450 - 450451 - 549550 - 599600 - 649650 - 650651 - 749750 - 799800 - 800801 - 899900 - 949950 - 999

    1,000 - 1,0001,001 - 1,0991,100 - 1,1491,150 - 1,1991,200 - 1,2491,250 - 1,2991,300 - 1,3491,350 - 1,3991,400 - 1,4001,401 - 1,5991,600 - 1,6001,601 - 1,7991,800 - 1,8991,900 - 1,9992,000 - 2,000

    Model

    5.68 - 6.795.69 - 6.805.73 - 6.855.75 - 6.885.82 - 6.965.83 - 6.985.88 - 7.035.92 - 7.085.82 - 6.965.87 - 7.025.92 - 7.085.94 - 7.105.93 - 7.095.92 - 7.085.96 - 7.125.96 - 7.125.98 - 7.156.00 - 7.176.03 - 7.216.03 - 7.226.09 - 7.296.09 - 7.286.10 - 7.29

    4,0504,0504,5504,5504,5504,5504,5504,5504,5504,5504,5504,5504,5504,5505,0505,0505,0505,0505,0505,0505,0505,0505,050

    1,6501,6501,9001,9002,0002,0002,0002,0002,2502,2502,2502,2502,4002,4002,4002,4002,4002,6002,6002,6002,6002,6002,600

    2,2002,2002,4002,4002,4502,4502,4502,4502,6502,6502,6502,6502,8002,8002,8002,8002,8002,9002,9002,9002,9002,9002,900

    6,1006,1007,7007,7009,2009,2009,4009,40011,30011,30011,70011,70013,10013,10014,70014,70014,80015,70016,80016,80016,80017,00017,000

    3,5003,5004,0004,0004,0004,0004,0004,0004,0004,0004,0004,0004,0004,0004,5004,5004,5004,5004,5004,5004,5004,5004,500

    7,6007,0009,6009,70011,10011,20011,40011,60013,60013,70014,40014,50016,10016,20018,30018,40018,60019,70020,80020,90021,00021,30021,400

    COP Height (C) mm

    ExtubationSpace

    Width (B)mm

    Length (A)mm

    Overall Dimension

    300 - 325326 - 350351 - 425426 - 450451 - 525526 - 550551 - 625626 - 650651 - 725726 - 750751 - 825826 - 850851 - 925926 - 950

    951 - 1,0251,026 - 1,0501,051 - 1,1001,101 - 1,1501,151 - 1,2251,226 - 1,2751,276 - 1,3251,326 - 1,3751,376 - 1,400

    300 - 325326 - 350351 - 425426 - 450451 - 525526 - 550551 - 625626 - 650651 - 725726 - 750751 - 825826 - 850851 - 925926 - 950

    951 - 1,0251,026 - 1,0501,051 - 1,1001,101 - 1,1501,151 - 1,2251,226 - 1,2751,276 - 1,3251,326 - 1,3751,376 - 1,400

    ■HC-F_GFG-SSC

    HC-F300GFG-SSCHC-F350GFG-SSCHC-F400GFG-SSCHC-F450GFG-SSCHC-F500GFG-SSCHC-F550GFG-SSCHC-F600GFG-SSCHC-F650GFG-SSCHC-F700GFG-SSCHC-F750GFG-SSCHC-F800GFG-SSCHC-F850GFG-SSCHC-F900GFG-SSCHC-F950GFG-SSCHC-F1000GFG-SSCHC-F1050GFG-SSCHC-F1100GFG-SSCHC-F1150GFG-SSCHC-F1200GFG-SSCHC-F1250GFG-SSCHC-F1300GFG-SSCHC-F1350GFG-SSCHC-F1400GFG-SSC

    Model

    5.57 - 6.665.58 - 6.685.61 - 6.715.65 - 6.755.71 - 6.835.73 - 6.855.77 - 6.905.81 - 6.945.71 - 6.835.76 - 6.895.80 - 6.935.82 - 6.965.81 - 6.945.81 - 6.945.83 - 6.975.84 - 6.995.86 - 7.015.88 - 7.035.91 - 7.065.92 - 7.075.97 - 7.145.97 - 7.145.98 - 7.15

    6,1006,1007,7007,7009,2009,2009,4009,40011,30011,30011,70011,70013,10013,10014,70014,70014,80015,70016,80016,80016,80017,00017,000

    7,6007,0009,6009,70011,10011,20011,40011,60013,60013,70014,40014,50016,10016,20018,30018,40018,60019,70020,80020,90021,00021,30021,400

    COP Height (C) mm

    ExtubationSpace

    Width (B)mm

    Length (A)mm

    Overall Dimension

    ■HC-F_GFG-SITSC

    4,0504,0504,5504,5504,5504,5504,5504,5504,5504,5504,5504,5504,5504,5505,0505,0505,0505,0505,0505,0505,0505,0505,050

    1,6501,6501,9001,9002,0002,0002,0002,0002,2502,2502,2502,2502,4002,4002,4002,4002,4002,6002,6002,6002,6002,6002,600

    2,2002,2002,4002,4002,4502,4502,4502,4502,6502,6502,6502,6502,8002,8002,8002,8002,8002,9002,9002,9002,9002,9002,900

    3,5003,5004,0004,0004,0004,0004,0004,0004,0004,0004,0004,0004,0004,0004,5004,5004,5004,5004,5004,5004,5004,5004,500

    HC-F300GFG-SITSCHC-F350GFG-SITSCHC-F400GFG-SITSCHC-F450GFG-SITSCHC-F500GFG-SITSCHC-F550GFG-SITSCHC-F600GFG-SITSCHC-F650GFG-SITSCHC-F700GFG-SITSCHC-F750GFG-SITSCHC-F800GFG-SITSCHC-F850GFG-SITSCHC-F900GFG-SITSCHC-F950GFG-SITSCHC-F1000GFG-SITSCHC-F1050GFG-SITSCHC-F1100GFG-SITSCHC-F1150GFG-SITSCHC-F1200GFG-SITSCHC-F1250GFG-SITSCHC-F1300GFG-SITSCHC-F1350GFG-SITSCHC-F1400GFG-SITSC

    Cooling CapacityUSRT

    Cooling CapacityUSRT

    Model COP

    Extubationspace

    Operating Weightkg

    Shipping Weightkg

    Operating Weightkg

    Shipping Weightkg

    Operating Weightkg

    Shipping Weightkg

    Operating Weightkg

    Shipping Weightkg

    ■ HC-F_GXG-SIT

    HC-F300GXG-SITHC-F350GXG-SITHC-F400GXG-SITHC-F450GXG-SITHC-F500GXG-SITHC-F550GXG-SITHC-F600GXG-SITHC-F650GXG-SITHC-F700GXG-SITHC-F750GXG-SITHC-F800GXG-SITHC-F850GXG-SITHC-F900GXG-SITHC-F950GXG-SITHC-F1000GXG-SITHC-F1050GXG-SITHC-F1100GXG-SITHC-F1150GXG-SITHC-F1200GXG-SITHC-F1250GXG-SITHC-F1300GXG-SITHC-F1350GXG-SIT

    300350400450451550600650651750800801900950

    1,0001,0011,1001,1501,2001,2501,3001,350

    3493994494505495996496507497998008999499991,0991,0991,1491,1991,2491,2991,3491,390

    ----------------------

    ----------------------

    5.145.155.295.295.475.515.595.525.485.545.635.485.545.555.695.635.675.675.725.735.735.74

    6.15 6.16 6.33 6.33 6.55 6.59 6.69 6.60 6.56 6.62 6.73 6.56 6.62 6.63 6.81 6.73 6.78 6.78 6.84 6.85 6.85 6.86

    Extubationspace

    3,0003,0003,0003,0003,5003,5003,5003,5003,5003,5003,5003,5003,5003,5004,0004,0004,0004,0004,0004,0004,0004,000

    5,8005,8007,0007,0008,4008,7008,9009,10010,70010,70011,10011,10012,40012,40013,90014,10014,30014,80015,80015,80015,80016,000

    7,0007,1008,5008,6009,90010,40010,50010,90012,60012,70013,30013,40014,80014,90016,90017,20017,50018,10019,10019,20019,30019,600

    2,2002,2002,4002,4002,4502,4502,4502,4502,6502,6502,6502,6502,8002,8002,8002,8002,9002,9002,9002,9002,9002,900

    Height (C)

    1,6501,6501,9001,9001,9002,0002,0002,0002,2502,2502,2502,2502,4002,4002,4002,4002,6002,6002,6002,6002,6002,600

    Width (B)

    3,5503,5503,5503,5504,0504,0504,0504,0504,0504,0504,0504,0504,0504,0504,5504,5504,5504,5504,5504,5504,5504,550

    Length (A)

    Overall Dimension mm

    Model

    ■ Starter Panel (Open star-delta)

    300 ~ 450500 ~ 600650 ~ 800850 ~ 10001050 ~ 1400

    Length800800

    1,0001,0001,500

    Width600750800800

    1,000

    Height2,1001,7001,9002,2002,100

    Dimensions (mm)

    GFG-SSC

    Model

    ■ Inverter Panel

    300350 ~ 450500 ~ 650700 ~ 850900 ~ 1400

    Length1,7001,9001,9002,1002,200

    Width950950950950950

    Height1,9001,9002,3002,3002,450

    Dimensions (mm)

    GFG-SITSC

    Model

    ■ Starter Panel (Open star-delta)

    300 ~ 450500 ~ 600650 ~ 800850 ~ 10001050 ~ 1400

    Length800800

    1,0001,0001,500

    Width600750800800

    1,000

    Height2,1001,7001,9002,2002,100

    Dimensions (mm)

    GXG-S

    Model

    ■ Inverter Panel

    300350 ~ 450500 ~ 650700 ~ 850900 ~ 1350

    Length1,7001,9001,9002,1002,200

    Width950950950950950

    Height1,9001,9002,3002,3002,450

    Dimensions (mm)

    GXG-SIT

    Specifications

    REMARKS1. Please consult with our sales staff or distributor for actual specifications for cooling capacity, expected kW input and COP, depending on selected operating parameters.2. The above specifications are subject to change without notice for technical improvements. * This table is applicable to chillers to be manufactured for normal water.3. Capacity control range is 100% to approx. 20%. (Minimum cooling capacity can be reduced to 10% as option.)4. Fouling factor is assumed to be 0.018m2K/kW for chilled water and 0.044m2K/kW for cooling water.5. Standard main power source : 380V/400V/415V/440V/460V (up to HC-F1400GFG-S), 3000V/3300V/6000V/6600V (any capacity, only constant speed), 10000V/11000V (F900GFG-S and above, only constant speed), AC, 50/60Hz, 3ph.6. Auxiliary power: AC 380V/50Hz/3φ/3W or 4W.7. Maximum working pressure is 1.0MPa for both chilled and cooling water. If higher maximum working pressure is required, please specify at inquiry. (Up to 2.5 MPa is available.)

    Constant Speed

    Inverter-controlled

    Constant Speed

    Inverter-controlled*1. Power sourse: High /Middle tension Standard starting method: Reactor

    Cooling CapacityUSRT

    Cooling CapacityUSRT

  • 7 8

    Model

    5.15 - 6.16 5.15 - 6.16 5.35 - 6.40 5.36 - 6.415.58 - 6.68 5.62 - 6.72 5.70 - 6.82 5.63 - 6.73 5.59 - 6.69 5.65 - 6.75 5.74 - 6.86 5.59 - 6.69 5.65 - 6.75 5.66 - 6.77 5.81 - 6.94 5.74 - 6.86 5.78 - 6.91 5.79 - 6.92 5.83 - 6.97 5.84 - 6.99 5.85 - 7.00 5.86 - 7.01 5.89 - 7.04 5.74 - 6.86 5.77 - 6.90 5.69 - 6.81 5.73 - 6.85 5.77 - 6.90 5.84 - 6.99

    3,5503,5503,5503,5504,0504,0504,0504,0504,0504,0504,0504,0504,0504,0504,5504,5504,5504,5504,5504,5504,5504,5504,5504,8504,8505,2505,2505,2505,250

    1,6501,6501,9001,9001,9002,0002,0002,0002,2502,2502,2502,2502,4002,4002,4002,4002,4002,6002,6002,6002,6002,6002,6003,3003,3003,5003,5003,5003,500

    2,2002,2002,4002,4002,4502,4502,4502,4502,6502,6502,6502,8002,8002,8002,8002,8002,8002,9002,9002,9002,9002,9002,9003,4003,4003,7003,7003,7003,700

    3,0003,0003,0003,0003,5003,5003,5003,5003,5003,5003,5003,5003,5003,5004,0004,0004,0004,0004,0004,0004,0004,0004,0004,0004,0004,5004,5004,5004,500

    5,8005,8007,0007,0008,4008,7008,9009,10010,70010,70011,10011,10012,40012,40013,90014,10014,30014,80015,80015,80015,80016,00016,00020,50020,70023,70024,00024,20024,500

    7,0007,1008,5008,6009,90010,40010,50010,90012,60012,70013,30013,40014,80014,90016,90017,20017,50018,10019,10019,20019,30019,60019,70024,30024,60027,50027,90028,20028,500

    COPHeight (C)Width (B)Length (A)

    Overall Dimension mm

    ■ HC-F_GXG-S

    REMARKS1. Please consult with our sales staff or distributor for actual specifications for cooling  capacity, expected kW input and COP, depending on selected operating parameters. 2. The above specifications are subject to change without notice for technical improvements.  * This table is applicable to chillers to be manufactured for normal water.3. Capacity control range is 100% to approx. 20%.  (Minimum cooling capacity can be reduced to 10% as option.) 4. Fouling factor is assumed to be 0.018m2K/kW for chilled water and 0.044m2K/kW for  cooling water. 5. Standard main power source : 380V/400V/415V/440V/460V (up to HC-F1400GXG-S),  3000V/3300V/6000V/6600V (any capacity, only constant speed),  10000V/11000V (F900GXG-S and above, only constant speed), AC, 50/60Hz, 3ph. 6. Auxiliary power: AC 380V/50Hz/3φ/3W or 4W.7. Maximum working pressure is 1.0MPa for both chilled and cooling water. If higher maximum  working pressure is required, please specify at inquiry. (Up to 2.5 MPa is available.)

    HC-F300GXG-SHC-F350GXG-SHC-F400GXG-SHC-F450GXG-SHC-F500GXG-SHC-F550GXG-SHC-F600GXG-SHC-F650GXG-SHC-F700GXG-SHC-F750GXG-SHC-F800GXG-SHC-F850GXG-SHC-F900GXG-SHC-F950GXG-SHC-F1000GXG-SHC-F1050GXG-SHC-F1100GXG-SHC-F1150GXG-SHC-F1200GXG-SHC-F1250GXG-SHC-F1300GXG-SHC-F1350GXG-SHC-F1400GXG-S

    HC-F1500GXG-S (*1)HC-F1600GXG-S (*1)HC-F1700GXG-S (*1)HC-F1800GXG-S (*1)HC-F1900GXG-S (*1)HC-F2000GXG-S (*1)

    300 - 349350 - 350351 - 449450 - 450451 - 549550 - 599600 - 649650 - 650651 - 749750 - 799800 - 800801 - 899900 - 949950 - 999

    1,000 - 1,0001,001 - 1,0991,100 - 1,1491,150 - 1,1991,200 - 1,2491,250 - 1,2991,300 - 1,3491,350 - 1,3991,400 - 1,4001,401 - 1,5991,600 - 1,6001,601 - 1,7991,800 - 1,8991,900 - 1,9992,000 - 2,000

    Model

    5.68 - 6.795.69 - 6.805.73 - 6.855.75 - 6.885.82 - 6.965.83 - 6.985.88 - 7.035.92 - 7.085.82 - 6.965.87 - 7.025.92 - 7.085.94 - 7.105.93 - 7.095.92 - 7.085.96 - 7.125.96 - 7.125.98 - 7.156.00 - 7.176.03 - 7.216.03 - 7.226.09 - 7.296.09 - 7.286.10 - 7.29

    4,0504,0504,5504,5504,5504,5504,5504,5504,5504,5504,5504,5504,5504,5505,0505,0505,0505,0505,0505,0505,0505,0505,050

    1,6501,6501,9001,9002,0002,0002,0002,0002,2502,2502,2502,2502,4002,4002,4002,4002,4002,6002,6002,6002,6002,6002,600

    2,2002,2002,4002,4002,4502,4502,4502,4502,6502,6502,6502,6502,8002,8002,8002,8002,8002,9002,9002,9002,9002,9002,900

    6,1006,1007,7007,7009,2009,2009,4009,40011,30011,30011,70011,70013,10013,10014,70014,70014,80015,70016,80016,80016,80017,00017,000

    3,5003,5004,0004,0004,0004,0004,0004,0004,0004,0004,0004,0004,0004,0004,5004,5004,5004,5004,5004,5004,5004,5004,500

    7,6007,0009,6009,70011,10011,20011,40011,60013,60013,70014,40014,50016,10016,20018,30018,40018,60019,70020,80020,90021,00021,30021,400

    COP Height (C) mm

    ExtubationSpace

    Width (B)mm

    Length (A)mm

    Overall Dimension

    300 - 325326 - 350351 - 425426 - 450451 - 525526 - 550551 - 625626 - 650651 - 725726 - 750751 - 825826 - 850851 - 925926 - 950

    951 - 1,0251,026 - 1,0501,051 - 1,1001,101 - 1,1501,151 - 1,2251,226 - 1,2751,276 - 1,3251,326 - 1,3751,376 - 1,400

    300 - 325326 - 350351 - 425426 - 450451 - 525526 - 550551 - 625626 - 650651 - 725726 - 750751 - 825826 - 850851 - 925926 - 950

    951 - 1,0251,026 - 1,0501,051 - 1,1001,101 - 1,1501,151 - 1,2251,226 - 1,2751,276 - 1,3251,326 - 1,3751,376 - 1,400

    ■HC-F_GFG-SSC

    HC-F300GFG-SSCHC-F350GFG-SSCHC-F400GFG-SSCHC-F450GFG-SSCHC-F500GFG-SSCHC-F550GFG-SSCHC-F600GFG-SSCHC-F650GFG-SSCHC-F700GFG-SSCHC-F750GFG-SSCHC-F800GFG-SSCHC-F850GFG-SSCHC-F900GFG-SSCHC-F950GFG-SSCHC-F1000GFG-SSCHC-F1050GFG-SSCHC-F1100GFG-SSCHC-F1150GFG-SSCHC-F1200GFG-SSCHC-F1250GFG-SSCHC-F1300GFG-SSCHC-F1350GFG-SSCHC-F1400GFG-SSC

    Model

    5.57 - 6.665.58 - 6.685.61 - 6.715.65 - 6.755.71 - 6.835.73 - 6.855.77 - 6.905.81 - 6.945.71 - 6.835.76 - 6.895.80 - 6.935.82 - 6.965.81 - 6.945.81 - 6.945.83 - 6.975.84 - 6.995.86 - 7.015.88 - 7.035.91 - 7.065.92 - 7.075.97 - 7.145.97 - 7.145.98 - 7.15

    6,1006,1007,7007,7009,2009,2009,4009,40011,30011,30011,70011,70013,10013,10014,70014,70014,80015,70016,80016,80016,80017,00017,000

    7,6007,0009,6009,70011,10011,20011,40011,60013,60013,70014,40014,50016,10016,20018,30018,40018,60019,70020,80020,90021,00021,30021,400

    COP Height (C) mm

    ExtubationSpace

    Width (B)mm

    Length (A)mm

    Overall Dimension

    ■HC-F_GFG-SITSC

    4,0504,0504,5504,5504,5504,5504,5504,5504,5504,5504,5504,5504,5504,5505,0505,0505,0505,0505,0505,0505,0505,0505,050

    1,6501,6501,9001,9002,0002,0002,0002,0002,2502,2502,2502,2502,4002,4002,4002,4002,4002,6002,6002,6002,6002,6002,600

    2,2002,2002,4002,4002,4502,4502,4502,4502,6502,6502,6502,6502,8002,8002,8002,8002,8002,9002,9002,9002,9002,9002,900

    3,5003,5004,0004,0004,0004,0004,0004,0004,0004,0004,0004,0004,0004,0004,5004,5004,5004,5004,5004,5004,5004,5004,500

    HC-F300GFG-SITSCHC-F350GFG-SITSCHC-F400GFG-SITSCHC-F450GFG-SITSCHC-F500GFG-SITSCHC-F550GFG-SITSCHC-F600GFG-SITSCHC-F650GFG-SITSCHC-F700GFG-SITSCHC-F750GFG-SITSCHC-F800GFG-SITSCHC-F850GFG-SITSCHC-F900GFG-SITSCHC-F950GFG-SITSCHC-F1000GFG-SITSCHC-F1050GFG-SITSCHC-F1100GFG-SITSCHC-F1150GFG-SITSCHC-F1200GFG-SITSCHC-F1250GFG-SITSCHC-F1300GFG-SITSCHC-F1350GFG-SITSCHC-F1400GFG-SITSC

    Cooling CapacityUSRT

    Cooling CapacityUSRT

    Model COP

    Extubationspace

    Operating Weightkg

    Shipping Weightkg

    Operating Weightkg

    Shipping Weightkg

    Operating Weightkg

    Shipping Weightkg

    Operating Weightkg

    Shipping Weightkg

    ■ HC-F_GXG-SIT

    HC-F300GXG-SITHC-F350GXG-SITHC-F400GXG-SITHC-F450GXG-SITHC-F500GXG-SITHC-F550GXG-SITHC-F600GXG-SITHC-F650GXG-SITHC-F700GXG-SITHC-F750GXG-SITHC-F800GXG-SITHC-F850GXG-SITHC-F900GXG-SITHC-F950GXG-SITHC-F1000GXG-SITHC-F1050GXG-SITHC-F1100GXG-SITHC-F1150GXG-SITHC-F1200GXG-SITHC-F1250GXG-SITHC-F1300GXG-SITHC-F1350GXG-SIT

    300350400450451550600650651750800801900950

    1,0001,0011,1001,1501,2001,2501,3001,350

    3493994494505495996496507497998008999499991,0991,0991,1491,1991,2491,2991,3491,390

    ----------------------

    ----------------------

    5.145.155.295.295.475.515.595.525.485.545.635.485.545.555.695.635.675.675.725.735.735.74

    6.15 6.16 6.33 6.33 6.55 6.59 6.69 6.60 6.56 6.62 6.73 6.56 6.62 6.63 6.81 6.73 6.78 6.78 6.84 6.85 6.85 6.86

    Extubationspace

    3,0003,0003,0003,0003,5003,5003,5003,5003,5003,5003,5003,5003,5003,5004,0004,0004,0004,0004,0004,0004,0004,000

    5,8005,8007,0007,0008,4008,7008,9009,10010,70010,70011,10011,10012,40012,40013,90014,10014,30014,80015,80015,80015,80016,000

    7,0007,1008,5008,6009,90010,40010,50010,90012,60012,70013,30013,40014,80014,90016,90017,20017,50018,10019,10019,20019,30019,600

    2,2002,2002,4002,4002,4502,4502,4502,4502,6502,6502,6502,6502,8002,8002,8002,8002,9002,9002,9002,9002,9002,900

    Height (C)

    1,6501,6501,9001,9001,9002,0002,0002,0002,2502,2502,2502,2502,4002,4002,4002,4002,6002,6002,6002,6002,6002,600

    Width (B)

    3,5503,5503,5503,5504,0504,0504,0504,0504,0504,0504,0504,0504,0504,0504,5504,5504,5504,5504,5504,5504,5504,550

    Length (A)

    Overall Dimension mm

    Model

    ■ Starter Panel (Open star-delta)

    300 ~ 450500 ~ 600650 ~ 800850 ~ 10001050 ~ 1400

    Length800800

    1,0001,0001,500

    Width600750800800

    1,000

    Height2,1001,7001,9002,2002,100

    Dimensions (mm)

    GFG-SSC

    Model

    ■ Inverter Panel

    300350 ~ 450500 ~ 650700 ~ 850900 ~ 1400

    Length1,7001,9001,9002,1002,200

    Width950950950950950

    Height1,9001,9002,3002,3002,450

    Dimensions (mm)

    GFG-SITSC

    Model

    ■ Starter Panel (Open star-delta)

    300 ~ 450500 ~ 600650 ~ 800850 ~ 10001050 ~ 1400

    Length800800

    1,0001,0001,500

    Width600750800800

    1,000

    Height2,1001,7001,9002,2002,100

    Dimensions (mm)

    GXG-S

    Model

    ■ Inverter Panel

    300350 ~ 450500 ~ 650700 ~ 850900 ~ 1350

    Length1,7001,9001,9002,1002,200

    Width950950950950950

    Height1,9001,9002,3002,3002,450

    Dimensions (mm)

    GXG-SIT

    Specifications

    REMARKS1. Please consult with our sales staff or distributor for actual specifications for cooling capacity, expected kW input and COP, depending on selected operating parameters.2. The above specifications are subject to change without notice for technical improvements. * This table is applicable to chillers to be manufactured for normal water.3. Capacity control range is 100% to approx. 20%. (Minimum cooling capacity can be reduced to 10% as option.)4. Fouling factor is assumed to be 0.018m2K/kW for chilled water and 0.044m2K/kW for cooling water.5. Standard main power source : 380V/400V/415V/440V/460V (up to HC-F1400GFG-S), 3000V/3300V/6000V/6600V (any capacity, only constant speed), 10000V/11000V (F900GFG-S and above, only constant speed), AC, 50/60Hz, 3ph.6. Auxiliary power: AC 380V/50Hz/3φ/3W or 4W.7. Maximum working pressure is 1.0MPa for both chilled and cooling water. If higher maximum working pressure is required, please specify at inquiry. (Up to 2.5 MPa is available.)

    Constant Speed

    Inverter-controlled

    Constant Speed

    Inverter-controlled*1. Power sourse: High /Middle tension Standard starting method: Reactor

    Cooling CapacityUSRT

    Cooling CapacityUSRT

  • 9 10

    The following table shows the standard scope of supply, but the actual scope depends on the contract. Please consult with our sales staff or distributor.

    Item

    Main Equipment

    Auxiliary Equipment

    Coating

    Out of Supply Scope

    Standard Scope

    Standard Scope of Supply

    a b c d e f g h i

    ■Positional Dimension of Water Piping (unit: mm)Positional dimension of nozzleModel: HCF_GFG-SSC

    HCF_GFG-SITSC

    300, 350400, 450500, 550600, 650700 ~ 850900, 950

    1000, 105011001150

    1200 ~ 1400

    673715734734810780780780858858

    933975

    1,0271,0271,1551,1601,1601,1601,2781,278

    398442474494430455475495456456

    616642695715730815835855836836

    33101102102107139139139164164

    339358400400500480480480500500

    444525535535562640640640668668

    290292320320380380380380444444

    420420420420420420420420420420

    a b c d e f g h iPositional dimension of nozzle

    300350, 400

    450500, 550

    600650, 700

    750800

    850, 900950

    1000, 10501100, 11501200, 12501300 ~ 14001450, 15001600, 17001800, 1900

    2000

    673714734734734810810800800800800858858979979

    1,0051,0051,005

    933974

    1,0271,0271,0271,1551,1551,1801,1801,1801,1801,2781,2781,4691,4691,5651,5651,565

    398422455475495410430436456456475437456523543584603623

    616622676696716710730796816816835817836963983

    1,0241,0431,063

    37899090909595139139139139164164257257269269269

    340358400400400500500480480480480500500600600700700700

    444525535535535562562640640640640668668925925897897897

    290292320320320380380380380380380444444500500580580580

    420420420420420420420420420420420420420612612620620620

    This dimensional outline drawing shows a standard nozzle location. Please consult with our sales staff or distributor in case of a 3-pass or 4-pass system.

    Dimensional Outline Drawing

    REMARKS1. Please consult with our sales staff or distributor for actual specifications for cooling  capacity, expected kW input and COP, depending on selected operating parameters. 2. The above specifications are subject to change without notice for technical improvements.  * This table is applicable to chillers to be manufactured for normal water.3. Capacity control range is 100% to approx. 20%.  (Minimum cooling capacity can be reduced to 10% as option.)4. Fouling factor is assumed to be 0.018m2K/kW for chilled water and 0.044m2K/kW for  cooling water.5. Standard main power source : 380V/400V/415V/440V/460V (up to HC-F1250GSG-S),   3000V/3300V/6000V/6600V (any capacity, only constant speed),  10000V/11000V (F800GSG-S and above, only constant speed), AC, 50/60Hz, 3ph. 6. Auxiliary power: AC 380V/50Hz/3φ/3W or 4W. 7. Maximum working pressure is 1.0MPa for both chilled and cooling water.  If higher maximum working pressure is required, please specify at inquiry.  (Up to 2.5 MPa is available.)

    Model COPHeight [C] ExtubationspaceWidth [B]Length [A]

    Overall Dimension (mm)

    300301351401451501551601651701751801851901951

    1,0011,0511,1011,1511,201

    3003504004505005506006507007508008509009501,0001,0501,1001,1501,2001,250

    - - - - - - - - - - - - - - - - - - - -

    4.57 4.59 4.70 4.73 4.96 4.97 4.98 5.02 5.09 5.14 5.23 5.27 5.29 5.12 5.17 5.26 5.23 5.26 5.30 5.33

    5.47 5.49 5.62 5.65 5.93 5.94 5.95 6.01 6.08 6.15 6.26 6.30 6.33 6.13 6.18 6.29 6.26 6.29 6.34 6.37

    - - - - - - - - - - - - - - - - - - - -

    2,7502,8002,8003,2503,2503,2503,2503,5003,5003,5003,5003,5003,7503,7503,7503,7503,7503,7503,7503,750

    1,9002,0002,0002,1002,1002,1002,1002,3502,3502,3502,4502,4502,4502,4502,4502,4502,6502,6502,6502,650

    2,3502,3502,3502,4502,4502,4502,4502,7002,7002,7002,8002,8002,8002,8002,8002,8002,9502,9502,9502,950

    2,0002,0002,0002,5002,5002,5002,5002,8002,8002,8002,8002,8002,8003,0003,0003,0003,0003,0003,0003,000

    5,5006,8006,9008,4008,5008,6008,80010,20010,30010,40011,50011,60011,70012,20012,30012,40013,20013,30013,40013,500

    6,7007,5007,6009,3009,4009,5009,80011,60011,70011,80013,00013,20013,30014,20014,30014,50015,30015,40015,50015,600

    ■ HC-F_GSG-SIT

    HC-F300GSG-SITHC-F350GSG-SITHC-F400GSG-SITHC-F450GSG-SITHC-F500GSG-SITHC-F550GSG-SITHC-F600GSG-SITHC-F650GSG-SITHC-F700GSG-SITHC-F750GSG-SITHC-F800GSG-SITHC-F850GSG-SITHC-F900GSG-SITHC-F950GSG-SITHC-F1000GSG-SITHC-F1050GSG-SITHC-F1100GSG-SITHC-F1150GSG-SITHC-F1200GSG-SITHC-F1250GSG-SIT

    a b c d e f g h iPositional dimension of nozzle

    300, 350400, 450

    500550

    600, 650700 ~ 850900, 950

    1000, 10501100, 11501200 ~ 1350

    140015001600

    1700, 18001900, 2000

    673715714734734810780780858858858979979

    1,0051,005

    933975974

    1,0271,0271,1551,1601,1601,2781,2781,2781,4691,4691,5651,565

    398442462474494430455475456475475562582603623

    616642662695715730815835836855855

    1,0021,0221,0431,063

    33101101102102107139139164164164257257269269

    339358358400400500480480500500500600600700700

    444525525535535562640640668668668925925897897

    290292292320320380380380444444444500500580580

    420420420420420420420420420420420612612620620

    4.60 - 5.504.66 - 5.584.75 - 5.684.78 - 5.725.02 - 6.015.00 - 5.975.03 - 6.025.07 - 6.065.13 - 6.145.17 - 6.185.34 - 6.385.38 - 6.445.39 - 6.455.19 - 6.205.23 - 6.255.26 - 6.295.29 - 6.335.33 - 6.375.35 - 6.395.38 - 6.445.37 - 6.425.38 - 6.445.38 - 6.445.39 - 6.455.40 - 6.465.47 - 6.555.46 - 6.535.39 - 6.455.46 - 6.525.49 - 6.57

    2,7502,8002,8003,2503,2503,2503,2503,5003,5003,5003,5003,5003,7503,7503,7503,7503,7503,7503,7503,7504,7004,7004,7004,7004,7005,0005,0005,0005,0005,000

    1,9002,0002,0002,1002,1002,1002,1002,3502,3502,3502,4502,4502,4502,4502,4502,4502,6502,6502,6502,6503,3003,3003,3003,3003,3003,5003,5003,5003,5003,500

    2,3502,3502,3502,4502,4502,4502,4502,7002,7002,7002,8002,8002,8002,8002,8002,8002,9502,9502,9502,9503,4003,4003,4003,4003,4003,7003,7003,7003,7003,700

    2,0002,0002,0002,5002,5002,5002,5002,8002,8002,8002,8002,8002,8003,0003,0003,0003,0003,0003,0003,0003,5003,5003,5003,5003,5004,0004,0004,0004,0004,000

    5,5006,8006,9008,4008,5008,6008,80010,20010,30010,40011,50011,60011,70012,20012,30012,40013,20013,30013,40013,50018,60018,70018,80018,90019,00021,00021,20021,50021,70022,000

    6,7007,5007,6009,3009,4009,5009,80011,60011,70011,80013,00013,20013,30014,20014,30014,50015,30015,40015,50015,60021,60021,70021,80022,00022,10024,70025,00025,40025,70026,000

    HC-F300GSG-SHC-F350GSG-SHC-F400GSG-SHC-F450GSG-SHC-F500GSG-SHC-F550GSG-SHC-F600GSG-SHC-F650GSG-SHC-F700GSG-SHC-F750GSG-SHC-F800GSG-SHC-F850GSG-SHC-F900GSG-SHC-F950GSG-SHC-F1000GSG-SHC-F1050GSG-SHC-F1100GSG-SHC-F1150GSG-SHC-F1200GSG-SHC-F1250GSG-S

    HC-F1300GSG-S (*1)HC-F1350GSG-S (*1)HC-F1400GSG-S (*1)HC-F1450GSG-S (*1)HC-F1500GSG-S (*1)HC-F1600GSG-S (*1)HC-F1700GSG-S (*1)HC-F1800GSG-S (*1)HC-F1900GSG-S (*1)HC-F2000GSG-S (*1)

    300 - 300301 - 350300 - 400401 - 450451 - 500501 - 550551 - 600601 - 650651 - 700701 - 750751 - 800801 - 850851 - 900901 - 950

    951 - 1,0001,001 - 1,0501,051 - 1,1001,101 - 1,1501,151 - 1,2001,201 - 1,2501,251 - 1,3001,301 - 1,3501,351 - 1,4001,401 - 1,4501,451 - 1,5001,501 - 1,6001,601 - 1,7001,701 - 1,8001,801 - 1,9001,901 - 2,000

    ■ HC-F_GSG-S

    Model COPHeight [C] ExtubationspaceWidth [B]Length [A]

    Overall Dimension (mm)

    Specifications Dimensional Data

    Model: HCF_GXG-S HCF_GXG-SIT

    Model: HCF_GSG-S HCF_GSG-SIT

    Constant Speed

    Inverter-controlled

    Model

    ■ Starter Panel (Open star-delta)

    300 ~ 400450 ~ 500550 ~ 800850 ~ 900950 ~ 1250

    Length800800

    1,0001,0001,500

    Width600750800800

    1,000

    Height2,1001,7001,9002,2002,100

    Dimensions (mm)

    GSG-S

    Model

    ■ Inverter PanelDimensions (mm)

    GSG-SIT

    300~400450~600650~800850~1250

    Length1,9001,9002,1002,200

    Width950950950950

    Height1,9002,3002,3002,450

    Compressor, Main motor, Lubrication system, Heat exchanger

    Safety device, Control panel, Standard accessories (Corrugated rubber vibration insulator plates, Oil strainer elements, Gasket for oil strainer elements, Dryer), Starter (optional)

    Chiller main unit: Anti-corrosive prime coatingControl panel: Finish coat (color: Munsell 5Y8/1 gloss)Starter (optional): Finish coat (color: Munsell 5Y7/1 semigloss)

    Foundation work, Carrying-in, Installation, Piping work, Cold insulation, Primary and secondary side electrical wiring, Commissioning for total system, Forced ventilation system, Outdoor discharge piping for safety valve, Counter flange, Bolt, Nut, Gasket, Foundationbolt, Refrigerant

    *1. Power sourse: High /Middle tension Standard starting method: Reactor

    iLength(A)

    ab

    cd

    e f g h

    Width(B)

    Hei

    ght(

    C)

    Cooling water outletChilled water outlet

    Cooling water inletChilled water inletControl panel

    CompressorMain motor

    EconomizerMotor terminal boxCondenser

    Evaporator Safety valve for evaporator

    Safety valve for condenser

    Side B Side A

    Cooling CapacityUSRT

    Cooling CapacityUSRT kg

    Operating Weightkg

    Shipping Weight

    kgOperating Weight

    kgShipping Weight

  • 9 10

    The following table shows the standard scope of supply, but the actual scope depends on the contract. Please consult with our sales staff or distributor.

    Item

    Main Equipment

    Auxiliary Equipment

    Coating

    Out of Supply Scope

    Standard Scope

    Standard Scope of Supply

    a b c d e f g h i

    ■Positional Dimension of Water Piping (unit: mm)Positional dimension of nozzleModel: HCF_GFG-SSC

    HCF_GFG-SITSC

    300, 350400, 450500, 550600, 650

    700 ~ 850900, 950

    1000, 105011001150

    1200 ~ 1400

    673715734734810780780780858858

    933975

    1,0271,0271,1551,1601,1601,1601,2781,278

    398442474494430455475495456456

    616642695715730815835855836836

    33101102102107139139139164164

    339358400400500480480480500500

    444525535535562640640640668668

    290292320320380380380380444444

    420420420420420420420420420420

    a b c d e f g h iPositional dimension of nozzle

    300350, 400

    450500, 550

    600650, 700

    750800

    850, 900950

    1000, 10501100, 11501200, 12501300 ~ 14001450, 15001600, 17001800, 1900

    2000

    673714734734734810810800800800800858858979979

    1,0051,0051,005

    933974

    1,0271,0271,0271,1551,1551,1801,1801,1801,1801,2781,2781,4691,4691,5651,5651,565

    398422455475495410430436456456475437456523543584603623

    616622676696716710730796816816835817836963983

    1,0241,0431,063

    37899090909595139139139139164164257257269269269

    340358400400400500500480480480480500500600600700700700

    444525535535535562562640640640640668668925925897897897

    290292320320320380380380380380380444444500500580580580

    420420420420420420420420420420420420420612612620620620

    This dimensional outline drawing shows a standard nozzle location. Please consult with our sales staff or distributor in case of a 3-pass or 4-pass system.

    Dimensional Outline Drawing

    REMARKS1. Please consult with our sales staff or distributor for actual specifications for cooling  capacity, expected kW input and COP, depending on selected operating parameters. 2. The above specifications are subject to change without notice for technical improvements.  * This table is applicable to chillers to be manufactured for normal water.3. Capacity control range is 100% to approx. 20%.  (Minimum cooling capacity can be reduced to 10% as option.)4. Fouling factor is assumed to be 0.018m2K/kW for chilled water and 0.044m2K/kW for  cooling water.5. Standard main power source : 380V/400V/415V/440V/460V (up to HC-F1250GSG-S),   3000V/3300V/6000V/6600V (any capacity, only constant speed),  10000V/11000V (F800GSG-S and above, only constant speed), AC, 50/60Hz, 3ph. 6. Auxiliary power: AC 380V/50Hz/3φ/3W or 4W. 7. Maximum working pressure is 1.0MPa for both chilled and cooling water.  If higher maximum working pressure is required, please specify at inquiry.  (Up to 2.5 MPa is available.)

    Model COPHeight [C] ExtubationspaceWidth [B]Length [A]

    Overall Dimension (mm)

    300301351401451501551601651701751801851901951

    1,0011,0511,1011,1511,201

    3003504004505005506006507007508008509009501,0001,0501,1001,1501,2001,250

    - - - - - - - - - - - - - - - - - - - -

    4.57 4.59 4.70 4.73 4.96 4.97 4.98 5.02 5.09 5.14 5.23 5.27 5.29 5.12 5.17 5.26 5.23 5.26 5.30 5.33

    5.47 5.49 5.62 5.65 5.93 5.94 5.95 6.01 6.08 6.15 6.26 6.30 6.33 6.13 6.18 6.29 6.26 6.29 6.34 6.37

    - - - - - - - - - - - - - - - - - - - -

    2,7502,8002,8003,2503,2503,2503,2503,5003,5003,5003,5003,5003,7503,7503,7503,7503,7503,7503,7503,750

    1,9002,0002,0002,1002,1002,1002,1002,3502,3502,3502,4502,4502,4502,4502,4502,4502,6502,6502,6502,650

    2,3502,3502,3502,4502,4502,4502,4502,7002,7002,7002,8002,8002,8002,8002,8002,8002,9502,9502,9502,950

    2,0002,0002,0002,5002,5002,5002,5002,8002,8002,8002,8002,8002,8003,0003,0003,0003,0003,0003,0003,000

    5,5006,8006,9008,4008,5008,6008,80010,20010,30010,40011,50011,60011,70012,20012,30012,40013,20013,30013,40013,500

    6,7007,5007,6009,3009,4009,5009,80011,60011,70011,80013,00013,20013,30014,20014,30014,50015,30015,40015,50015,600

    ■ HC-F_GSG-SIT

    HC-F300GSG-SITHC-F350GSG-SITHC-F400GSG-SITHC-F450GSG-SITHC-F500GSG-SITHC-F550GSG-SITHC-F600GSG-SITHC-F650GSG-SITHC-F700GSG-SITHC-F750GSG-SITHC-F800GSG-SITHC-F850GSG-SITHC-F900GSG-SITHC-F950GSG-SITHC-F1000GSG-SITHC-F1050GSG-SITHC-F1100GSG-SITHC-F1150GSG-SITHC-F1200GSG-SITHC-F1250GSG-SIT

    a b c d e f g h iPositional dimension of nozzle

    300, 350400, 450

    500550

    600, 650700 ~ 850900, 950

    1000, 10501100, 1150

    1200 ~ 1350140015001600

    1700, 18001900, 2000

    673715714734734810780780858858858979979

    1,0051,005

    933975974

    1,0271,0271,1551,1601,1601,2781,2781,2781,4691,4691,5651,565

    398442462474494430455475456475475562582603623

    616642662695715730815835836855855

    1,0021,0221,0431,063

    33101101102102107139139164164164257257269269

    339358358400400500480480500500500600600700700

    444525525535535562640640668668668925925897897

    290292292320320380380380444444444500500580580

    420420420420420420420420420420420612612620620

    4.60 - 5.504.66 - 5.584.75 - 5.684.78 - 5.725.02 - 6.015.00 - 5.975.03 - 6.025.07 - 6.065.13 - 6.145.17 - 6.185.34 - 6.385.38 - 6.445.39 - 6.455.19 - 6.205.23 - 6.255.26 - 6.295.29 - 6.335.33 - 6.375.35 - 6.395.38 - 6.445.37 - 6.425.38 - 6.445.38 - 6.445.39 - 6.455.40 - 6.465.47 - 6.555.46 - 6.535.39 - 6.455.46 - 6.525.49 - 6.57

    2,7502,8002,8003,2503,2503,2503,2503,5003,5003,5003,5003,5003,7503,7503,7503,7503,7503,7503,7503,7504,7004,7004,7004,7004,7005,0005,0005,0005,0005,000

    1,9002,0002,0002,1002,1002,1002,1002,3502,3502,3502,4502,4502,4502,4502,4502,4502,6502,6502,6502,6503,3003,3003,3003,3003,3003,5003,5003,5003,5003,500

    2,3502,3502,3502,4502,4502,4502,4502,7002,7002,7002,8002,8002,8002,8002,8002,8002,9502,9502,9502,9503,4003,4003,4003,4003,4003,7003,7003,7003,7003,700

    2,0002,0002,0002,5002,5002,5002,5002,8002,8002,8002,8002,8002,8003,0003,0003,0003,0003,0003,0003,0003,5003,5003,5003,5003,5004,0004,0004,0004,0004,000

    5,5006,8006,9008,4008,5008,6008,80010,20010,30010,40011,50011,60011,70012,20012,30012,40013,20013,30013,40013,50018,60018,70018,80018,90019,00021,00021,20021,50021,70022,000

    6,7007,5007,6009,3009,4009,5009,80011,60011,70011,80013,00013,20013,30014,20014,30014,50015,30015,40015,50015,60021,60021,70021,80022,00022,10024,70025,00025,40025,70026,000

    HC-F300GSG-SHC-F350GSG-SHC-F400GSG-SHC-F450GSG-SHC-F500GSG-SHC-F550GSG-SHC-F600GSG-SHC-F650GSG-SHC-F700GSG-SHC-F750GSG-SHC-F800GSG-SHC-F850GSG-SHC-F900GSG-SHC-F950GSG-SHC-F1000GSG-SHC-F1050GSG-SHC-F1100GSG-SHC-F1150GSG-SHC-F1200GSG-SHC-F1250GSG-S

    HC-F1300GSG-S (*1)HC-F1350GSG-S (*1)HC-F1400GSG-S (*1)HC-F1450GSG-S (*1)HC-F1500GSG-S (*1)HC-F1600GSG-S (*1)HC-F1700GSG-S (*1)HC-F1800GSG-S (*1)HC-F1900GSG-S (*1)HC-F2000GSG-S (*1)

    300 - 300301 - 350300 - 400401 - 450451 - 500501 - 550551 - 600601 - 650651 - 700701 - 750751 - 800801 - 850851 - 900901 - 950

    951 - 1,0001,001 - 1,0501,051 - 1,1001,101 - 1,1501,151 - 1,2001,201 - 1,2501,251 - 1,3001,301 - 1,3501,351 - 1,4001,401 - 1,4501,451 - 1,5001,501 - 1,6001,601 - 1,7001,701 - 1,8001,801 - 1,9001,901 - 2,000

    ■ HC-F_GSG-S

    Model COPHeight [C] ExtubationspaceWidth [B]Length [A]

    Overall Dimension (mm)

    Specifications Dimensional Data

    Model: HCF_GXG-S HCF_GXG-SIT

    Model: HCF_GSG-S HCF_GSG-SIT

    Constant Speed

    Inverter-controlled

    Model

    ■ Starter Panel (Open star-delta)

    300 ~ 400450 ~ 500550 ~ 800850 ~ 900950 ~ 1250

    Length800800

    1,0001,0001,500

    Width600750800800

    1,000

    Height2,1001,7001,9002,2002,100

    Dimensions (mm)

    GSG-S

    Model

    ■ Inverter PanelDimensions (mm)

    GSG-SIT

    300~400450~600650~800850~1250

    Length1,9001,9002,1002,200

    Width950950950950

    Height1,9002,3002,3002,450

    Compressor, Main motor, Lubrication system, Heat exchanger

    Safety device, Control panel, Standard accessories (Corrugated rubber vibration insulator plates, Oil strainer elements, Gasket for oil strainer elements, Dryer), Starter (optional)

    Chiller main unit: Anti-corrosive prime coatingControl panel: Finish coat (color: Munsell 5Y8/1 gloss)Starter (optional): Finish coat (color: Munsell 5Y7/1 semigloss)

    Foundation work, Carrying-in, Installation, Piping work, Cold insulation, Primary and secondary side electrical wiring, Commissioning for total system, Forced ventilation system, Outdoor discharge piping for safety valve, Counter flange, Bolt, Nut, Gasket, Foundationbolt, Refrigerant

    *1. Power sourse: High /Middle tension Standard starting method: Reactor

    iLength(A)

    ab

    cd

    e f g h

    Width(B)

    Hei

    ght(

    C)

    Cooling water outletChilled water outlet

    Cooling water inletChilled water inletControl panel

    CompressorMain motor

    EconomizerMotor terminal boxCondenser

    Evaporator Safety valve for evaporator

    Safety valve for condenser

    Side B Side A

    Cooling CapacityUSRT

    Cooling CapacityUSRT kg

    Operating Weightkg

    Shipping Weight

    kgOperating Weight

    kgShipping Weight

  • CentrifugalChiller High EfficiencyGFG-S/SIT Series

    GXG-S/SIT SeriesGSG-S/SIT Series

    G700DLV

    Printed in Japan (H) MR-E070P Mar. 2017

    http://www.jci-hitachi.com