Page 1: CENTRIC - gamatronic.com · Power Usage Effectiveness (PUE) Centric is an ideal efficient UPS for Tier 3 and 4 data centers with a low load. The Centric can achieve 96% efficiency

CENTRICAN ADVANCED

MODULAR UPS

FROM 25KW

UP TO 1600KW

CENTRIC

GAMATRONIC, A SolarEdge Division

17 Hartom Street, Jerusalem 9777517, Israel Tel: +972-2-5888222 Fax: +972-2-5828875| [email protected]| www.gamatronic.com

Page 2: CENTRIC - gamatronic.com · Power Usage Effectiveness (PUE) Centric is an ideal efficient UPS for Tier 3 and 4 data centers with a low load. The Centric can achieve 96% efficiency

The Centric UPS from 25kW to 1.6MWGamatronic is proud to present the Centric, an innovative UPS, available in many configurations (25, 50, 75, 100, 175, 200, 400, 600, 800, 1000, 1200, 1400, 1600kW) and in three versions - a 50kW base, a 100kW base and a 200kW base.

The Centric provides reliable, clean and regulated AC power. For users with greater power requirements, up to eight Centric units can be operated in a parallel configuration for eight times the power.

The Centric’s double conversion topology provides high quality power regulation in accordance with IEC 62040 VFI-SS-111, and AC/AC efficiency up to 96%.

The Centric battery is true online as per IEC 62040, guaranteeing instant availability of backup power in the event of mains failure, and provides high unique DC/AC efficiency of up to 98%.

The Centric’s vertical and horizontal modularity reduce the down time thus providing a fault tolerant power source to critical loads and applications.

The Centric’s reliability, flexibility, intelligent features and design make it a great choice for your data center.

Features Advanced colorful LCD touch screen

True on-line battery

Up to 96% efficiency

High power output

Small footprint

Lightweight

Optional manual maintenance bypass switch*

Hot swappable power modules

Hot swappable system controller

* For 100kW base2 3

CENTRIC

Page 3: CENTRIC - gamatronic.com · Power Usage Effectiveness (PUE) Centric is an ideal efficient UPS for Tier 3 and 4 data centers with a low load. The Centric can achieve 96% efficiency

Power Usage Effectiveness (PUE)

Centric is an ideal efficient UPS for Tier 3 and 4 data centers with a low load. The Centric can achieve 96% efficiency in a load between 40% to 80%.

2N+1 (Tier 4) Application

25% LOAD 2 x 200kW

25% LOAD 2 x 200kW

100% IT LOAD

The PC-based Centric controller enhances data centre management systems with its unique abilities:

4 5

CENTRIC

CENTRIC

Built-in flexible connectivity

Intelligent interface

Fail-safe (non-critical for UPS operation)

Hot swappable

RS232

Modbus RS485

Modbus TCP/IP

USB

SNMP

Configurable web interface

Unlimited servers shutdown

Unlimited email notifications

Data-rich system log

Multi-language interface

9191.592

92.593

93.594

94.595

95.596

0 20 40 60 80 100 120

Effic

ienc

y

Power(%)

Centric 200kVA Efficiency

CENTRIC

Page 4: CENTRIC - gamatronic.com · Power Usage Effectiveness (PUE) Centric is an ideal efficient UPS for Tier 3 and 4 data centers with a low load. The Centric can achieve 96% efficiency

Footprint Power: 49W / cm2 ׀ Power Density: 0.4W / cm3

CENTRIC Power Density

76 cm

123 cm

202 cm

Vertical modularity in a basic unit is 25kW per power module; the vertical stack is scalable to up to 8 power modules (200kW). Horizontal modularity of a basic unit is up to 200kW, the horizontal scalability is up to 8 units (1600kW).

Modularity and Scalability

Front View202 cm

350 cm

123 cm

76 cm54 cm

6 7

CENTRIC

Page 5: CENTRIC - gamatronic.com · Power Usage Effectiveness (PUE) Centric is an ideal efficient UPS for Tier 3 and 4 data centers with a low load. The Centric can achieve 96% efficiency

Vertical and Horizontal Redundancy with Decentralized or Centralized Battery

Solutions

Up to 175kW Vertical & Horizontal

Redundancy

Up to 200kW Horizontal

Redundancy

Up to 350kWVertical

Redundancy

Up to 75kW Vertical & Horizontal Redundancy

Up to 100kW Horizontal

Redundancy

Up to 150kW VerticalRedundancy

Up to 150kW Vertical & Horizontal

Redundancy

Up to 200kW Horizontal

Redundancy

Up to 225kWVertical

Redundancy

Up to 225kW Vertical & Horizontal

Redundancy

Up to 300kW Horizontal

Redundancy

Up to 300kW Vertical

Redundancy

Up to 350kW Vertical & Horizontal

Redundancy

Up to 400kW Horizontal

Redundancy

Up to 525kWVertical

Redundancy

Up to 525kW Vertical & Horizontal

Redundancy

Up to 600kW Horizontal

Redundancy

Up to 700kWVertical

Redundancy

Up to 700kW Vertical & Horizontal

Redundancy

Up to 800kW Horizontal

Redundancy

Up to 875kWVertical

Redundancy

CENTRIC UPS System Specifications

8 9

CENTRICTopology Modular, hot swappable, double-conversion, VFI, online batteryOperation ContinuousINPUT Voltage (V) 3x400 (4 wires + Gnd)

Voltage range (%)-20 / +15 (360 ~ 460 Vac: full power; 320 ~ 360 Vac: derated 20 %)

Current (A) 3 × 42 per module – no inrush current at startup Rectifier frequency (Hz) 40 ~ 70 Power walk-in (sec) >60Power factor correction >0.99THDI (%) <3 Inrush current NoneOUTPUTRated Power kW) 25 ~ 1600Nominal frequency (Hz) 50/60 Frequency tracking range (Hz) ±(0.5, 1, 2, 3, 4), selectableFrequency tracking slew rate (Hz/sec) 1Frequency (in free-running mode) (Hz) 50/60 ±0.1 %Nominal voltage (Vac) 3x380, 3x400, 3x415 (4 wires + Gnd)Static voltage regulation (%) ±1Regulation for 100 % unbalanced load (%) ±1Dynamic response to 100 % load step (%) ±2

Overload withstand

Inverter modeLoad Level Withstand Time101% < load < 110% Not limited, alarm only111% < load < 125% 11 minutes126% < load < 150% 60 sec.>150% Transfer to bypass

Bypass mode Limited by installed protective device (bypass circuit breaker)

Required by installed protective device (bypass circuit breaker)

Waveform SinusoidalTHD (%) Linear load: <2; non-linear load: <6Load CF (max) 6:1Power factor 1AC/AC efficiency (nominal) (%) Up to 96BATTERIES DC-link voltage (Vdc) +/-405V Quantity 60 × 12 VdcType Sealed, lead-acid. Lithium-ion batteries also supportedGENERAL Maximum power dissipation (Po=25 kW) N*1041 W (N*3552 BTU/h), where N = # modulesAmbient temperature (°C) -10 to +40 (operating), -20 to +60 (storage)Relative humidity (%) 95 maximum, non-condensingAltitude (m) 1500 without deratingEnclosure IP20Cooling system Multi-fan with speed control (forced)DESIGN & MANUFACTURING STANDARDSSafety IEC 62040-1EMC IEC 62040-2Design classification IEC 62040-3Low magnetic field radiation EMF as per ICNIRPUPS BASE 50KW 100KW 200KW# POWER MODULES 1 2 1 2 3 4 1 2 3 4 5 6 7 8POWER OUTPUT (kW/kVA) 25 50 25 50 75 100 25 50 75 100 125 150 175 200

Height (mm) 1570 with battery (600 w/o battery) 965 1230

Width (mm) 540Depth (mm) 757

Weight (kg) w/o batt. box 66 with battery box 102.4 122.2 142 161.8 89.9 109.7 129.5 149.3 169.1 188.9 208.7 228.5

Page 6: CENTRIC - gamatronic.com · Power Usage Effectiveness (PUE) Centric is an ideal efficient UPS for Tier 3 and 4 data centers with a low load. The Centric can achieve 96% efficiency

CENTRIC

Technical Specifications for the System Controller

Display LCD flat panel, touch-sensitive

Other indicators Audible alarm

Analog input channels 4 input dry contacts (N.O. / N.C.)

Real-time clock (RTC) Yes, with backup

Power meter kVA, kW, PF

Volt-free outputs (dry contacts) 6 outputs, rated 48 V / 1 A

Output dry contacts

AC failureDC failureUPS module(s) failureLoad on bypassBattery test failureOver/under temperatureOverload(Each system alarm type can be routed to the dry contact of your choice)

Communication ports Serial, Ethernet, USB

Communication protocols RS232, RS485, TCP/IP, SNMP, Modbus

Communications with system modules Serial, isolated

Events log 500 events

System operation without controller Unchanged

On-screen parameters

Load bar-graph3-phase voltages3-phase currentsBattery voltageStatus of each UPS moduleStatic-switch parameters and statusBattery sensor temperature

RTC operation without power Indefinitely

Power requirements 3 × 400 Vac and 405 Vdc

Remote indication panel capability Yes

* All specifications are subject to change without prior notice.

Choose the Centric and enjoy a reliable, clean, regulated AC power UPS.

This is the kind of feedback we continually receive from our customers:

“We are very satisfied with the Centric’s performance and back up of the critical load in the data center.”

With Regards,

Jacob Shaaltiel

Business Manager, Data Center Consulting

Technology Consulting

Hewlett-Packard (Israel) Ltd.

10 11

Page 7: CENTRIC - gamatronic.com · Power Usage Effectiveness (PUE) Centric is an ideal efficient UPS for Tier 3 and 4 data centers with a low load. The Centric can achieve 96% efficiency

Gamatronic, A SolarEdge Division, provides reliable and flexible power solutions to ensure optimal power efficiency. Contact us for more information.

Let our team of experts find a solution that would best serve your needs.

Our Power, Your Confidence

www.gamatronic.comwww.gamatronic.com5112018