centric - gamatronic.com · power usage effectiveness (pue) centric is an ideal efficient ups for...
TRANSCRIPT
CENTRICAN ADVANCED
MODULAR UPS
FROM 25KW
UP TO 1600KW
CENTRIC
GAMATRONIC, A SolarEdge Division
17 Hartom Street, Jerusalem 9777517, Israel Tel: +972-2-5888222 Fax: +972-2-5828875| [email protected]| www.gamatronic.com
The Centric UPS from 25kW to 1.6MWGamatronic is proud to present the Centric, an innovative UPS, available in many configurations (25, 50, 75, 100, 175, 200, 400, 600, 800, 1000, 1200, 1400, 1600kW) and in three versions - a 50kW base, a 100kW base and a 200kW base.
The Centric provides reliable, clean and regulated AC power. For users with greater power requirements, up to eight Centric units can be operated in a parallel configuration for eight times the power.
The Centric’s double conversion topology provides high quality power regulation in accordance with IEC 62040 VFI-SS-111, and AC/AC efficiency up to 96%.
The Centric battery is true online as per IEC 62040, guaranteeing instant availability of backup power in the event of mains failure, and provides high unique DC/AC efficiency of up to 98%.
The Centric’s vertical and horizontal modularity reduce the down time thus providing a fault tolerant power source to critical loads and applications.
The Centric’s reliability, flexibility, intelligent features and design make it a great choice for your data center.
Features Advanced colorful LCD touch screen
True on-line battery
Up to 96% efficiency
High power output
Small footprint
Lightweight
Optional manual maintenance bypass switch*
Hot swappable power modules
Hot swappable system controller
* For 100kW base2 3
CENTRIC
Power Usage Effectiveness (PUE)
Centric is an ideal efficient UPS for Tier 3 and 4 data centers with a low load. The Centric can achieve 96% efficiency in a load between 40% to 80%.
2N+1 (Tier 4) Application
25% LOAD 2 x 200kW
25% LOAD 2 x 200kW
100% IT LOAD
The PC-based Centric controller enhances data centre management systems with its unique abilities:
4 5
CENTRIC
CENTRIC
Built-in flexible connectivity
Intelligent interface
Fail-safe (non-critical for UPS operation)
Hot swappable
RS232
Modbus RS485
Modbus TCP/IP
USB
SNMP
Configurable web interface
Unlimited servers shutdown
Unlimited email notifications
Data-rich system log
Multi-language interface
9191.592
92.593
93.594
94.595
95.596
0 20 40 60 80 100 120
Effic
ienc
y
Power(%)
Centric 200kVA Efficiency
CENTRIC
Footprint Power: 49W / cm2 ׀ Power Density: 0.4W / cm3
CENTRIC Power Density
76 cm
123 cm
202 cm
Vertical modularity in a basic unit is 25kW per power module; the vertical stack is scalable to up to 8 power modules (200kW). Horizontal modularity of a basic unit is up to 200kW, the horizontal scalability is up to 8 units (1600kW).
Modularity and Scalability
Front View202 cm
350 cm
123 cm
76 cm54 cm
6 7
CENTRIC
Vertical and Horizontal Redundancy with Decentralized or Centralized Battery
Solutions
Up to 175kW Vertical & Horizontal
Redundancy
Up to 200kW Horizontal
Redundancy
Up to 350kWVertical
Redundancy
Up to 75kW Vertical & Horizontal Redundancy
Up to 100kW Horizontal
Redundancy
Up to 150kW VerticalRedundancy
Up to 150kW Vertical & Horizontal
Redundancy
Up to 200kW Horizontal
Redundancy
Up to 225kWVertical
Redundancy
Up to 225kW Vertical & Horizontal
Redundancy
Up to 300kW Horizontal
Redundancy
Up to 300kW Vertical
Redundancy
Up to 350kW Vertical & Horizontal
Redundancy
Up to 400kW Horizontal
Redundancy
Up to 525kWVertical
Redundancy
Up to 525kW Vertical & Horizontal
Redundancy
Up to 600kW Horizontal
Redundancy
Up to 700kWVertical
Redundancy
Up to 700kW Vertical & Horizontal
Redundancy
Up to 800kW Horizontal
Redundancy
Up to 875kWVertical
Redundancy
CENTRIC UPS System Specifications
8 9
CENTRICTopology Modular, hot swappable, double-conversion, VFI, online batteryOperation ContinuousINPUT Voltage (V) 3x400 (4 wires + Gnd)
Voltage range (%)-20 / +15 (360 ~ 460 Vac: full power; 320 ~ 360 Vac: derated 20 %)
Current (A) 3 × 42 per module – no inrush current at startup Rectifier frequency (Hz) 40 ~ 70 Power walk-in (sec) >60Power factor correction >0.99THDI (%) <3 Inrush current NoneOUTPUTRated Power kW) 25 ~ 1600Nominal frequency (Hz) 50/60 Frequency tracking range (Hz) ±(0.5, 1, 2, 3, 4), selectableFrequency tracking slew rate (Hz/sec) 1Frequency (in free-running mode) (Hz) 50/60 ±0.1 %Nominal voltage (Vac) 3x380, 3x400, 3x415 (4 wires + Gnd)Static voltage regulation (%) ±1Regulation for 100 % unbalanced load (%) ±1Dynamic response to 100 % load step (%) ±2
Overload withstand
Inverter modeLoad Level Withstand Time101% < load < 110% Not limited, alarm only111% < load < 125% 11 minutes126% < load < 150% 60 sec.>150% Transfer to bypass
Bypass mode Limited by installed protective device (bypass circuit breaker)
Required by installed protective device (bypass circuit breaker)
Waveform SinusoidalTHD (%) Linear load: <2; non-linear load: <6Load CF (max) 6:1Power factor 1AC/AC efficiency (nominal) (%) Up to 96BATTERIES DC-link voltage (Vdc) +/-405V Quantity 60 × 12 VdcType Sealed, lead-acid. Lithium-ion batteries also supportedGENERAL Maximum power dissipation (Po=25 kW) N*1041 W (N*3552 BTU/h), where N = # modulesAmbient temperature (°C) -10 to +40 (operating), -20 to +60 (storage)Relative humidity (%) 95 maximum, non-condensingAltitude (m) 1500 without deratingEnclosure IP20Cooling system Multi-fan with speed control (forced)DESIGN & MANUFACTURING STANDARDSSafety IEC 62040-1EMC IEC 62040-2Design classification IEC 62040-3Low magnetic field radiation EMF as per ICNIRPUPS BASE 50KW 100KW 200KW# POWER MODULES 1 2 1 2 3 4 1 2 3 4 5 6 7 8POWER OUTPUT (kW/kVA) 25 50 25 50 75 100 25 50 75 100 125 150 175 200
Height (mm) 1570 with battery (600 w/o battery) 965 1230
Width (mm) 540Depth (mm) 757
Weight (kg) w/o batt. box 66 with battery box 102.4 122.2 142 161.8 89.9 109.7 129.5 149.3 169.1 188.9 208.7 228.5
CENTRIC
Technical Specifications for the System Controller
Display LCD flat panel, touch-sensitive
Other indicators Audible alarm
Analog input channels 4 input dry contacts (N.O. / N.C.)
Real-time clock (RTC) Yes, with backup
Power meter kVA, kW, PF
Volt-free outputs (dry contacts) 6 outputs, rated 48 V / 1 A
Output dry contacts
AC failureDC failureUPS module(s) failureLoad on bypassBattery test failureOver/under temperatureOverload(Each system alarm type can be routed to the dry contact of your choice)
Communication ports Serial, Ethernet, USB
Communication protocols RS232, RS485, TCP/IP, SNMP, Modbus
Communications with system modules Serial, isolated
Events log 500 events
System operation without controller Unchanged
On-screen parameters
Load bar-graph3-phase voltages3-phase currentsBattery voltageStatus of each UPS moduleStatic-switch parameters and statusBattery sensor temperature
RTC operation without power Indefinitely
Power requirements 3 × 400 Vac and 405 Vdc
Remote indication panel capability Yes
* All specifications are subject to change without prior notice.
Choose the Centric and enjoy a reliable, clean, regulated AC power UPS.
This is the kind of feedback we continually receive from our customers:
“We are very satisfied with the Centric’s performance and back up of the critical load in the data center.”
With Regards,
Jacob Shaaltiel
Business Manager, Data Center Consulting
Technology Consulting
Hewlett-Packard (Israel) Ltd.
10 11
Gamatronic, A SolarEdge Division, provides reliable and flexible power solutions to ensure optimal power efficiency. Contact us for more information.
Let our team of experts find a solution that would best serve your needs.
Our Power, Your Confidence
www.gamatronic.comwww.gamatronic.com5112018