centralized remote monitoring of renewable power plants
DESCRIPTION
Centralized Remote Monitoring of Renewable Power Plants. Abhinav Jain. Domain Consultant. Wipro Technologies - Overview. Sustained Growth. Partner to Industry Leaders. Global Presence. Attracts the Best Talent. Leaders. $ 5.2*. 953*. 54. Top 25. US $ Billion in Revenues - PowerPoint PPT PresentationTRANSCRIPT
© 2012 WIPRO LTD | WWW.WIPRO.COM1
Centralized Remote Monitoring of Renewable Power Plants
Abhinav Jain
Domain Consultant
© 2012 WIPRO LTD | WWW.WIPRO.COM2
US $ Billion in Revenues
(28% CAGR over 6 years)
$ 5.2*Active Global Clients
(150+ fortune 500 customers)
953* Top 25Countries
54
Attracts theBest Talent
Wipro Technologies - Overview
Sustained Growth
Partner to IndustryLeaders
LeadersGlobal
Presence
(*Figures for Q3 2011 – 12 for Global IT Business)
• Includes Global IT Services Business and Products
**List announced by Aon Hewitt, The RBL Group and Fortune
(Products revenue - as per Indian GAAP converted to USD based on realized exchange rate of IT
Services business)
Employees
136734* Company for Leaders, globally**
© 2012 WIPRO LTD | WWW.WIPRO.COM3
Wipro: Integrated Service Offerings
Pharma & HLS
ENUManufacturing & Hi-Tech
Retail, CPG, Transportation& Government
Financial Services
Business Application Services (24000+ )
Technology Infrastructure Services (15000+)
Business Process Outsourcing (21000+ )
Consulting (700+)
Telecom & Media
Product Engineering Services (18000+)
Analytics and Information Management (5000+)
Utilities & retail
Smart Grid
Generation & Renewable
Transmission & Distribution
HSSE
Oil & Gas Upstream & Downstream
Mining & Metals
CEO (ETRM)
Service lines
Industry verticals
© 2012 WIPRO LTD | WWW.WIPRO.COM4
Renewable Business Functions
Current Automation State and Challenges
Approach to Solution
Demo Dashboard and Roadmap
Agenda
2
3
1
4
© 2012 WIPRO LTD | WWW.WIPRO.COM5
Renewable Business FunctionsIT and Automation Scenarios
© 2012 WIPRO LTD | WWW.WIPRO.COM6
Renewable Value Chain
Engineering & Construction
Generation and
Operations
Plant Maintenance
Grid Integration
• Design and Build• Technology agnostic
engineering• Plant life cycle
Management• Design services
• SCADA and Plant monitoring• Production forecasting• Generation Control• Alarms and Notifications• Report generation• Substation management
• Asset Management• GIS integration• Workforce Automation• PPA management (Settlements)• Back-office Integration• KPIs and Reports dashboard
• Overall Production forecasting• Delta forecasting• Dispatch control and• Scheduling• Substation monitoring• Grid Monitoring• Commercial management• Congestion & curtailment• Situational intelligence
© 2012 WIPRO LTD | WWW.WIPRO.COM7
Current automation state and challengesIT and Automation Scenarios
© 2012 WIPRO LTD | WWW.WIPRO.COM8
Current IT and Automation Practices
© 2012 WIPRO LTD | WWW.WIPRO.COM9
Business Challenges
• More number of plants and labor• Dispersed plants at remote locationsHigh Operational Cost
• Huge number of plant with diverse set of data• Plants are monitored and controlled locallyRestrained Growth
• Multiple plants using multiple technologies • Huge cost of hardware agnostic technologies
System Hardware Dependency
• Intermittent nature of renewable resources• Real time updates in production planning
Plant Production Reliability
© 2012 WIPRO LTD | WWW.WIPRO.COM10
Approach to SolutionIT and Automation Scenarios
© 2012 WIPRO LTD | WWW.WIPRO.COM11
Monitoring: The Context
Who•Wind/Solar plant IPPs•Wind/Solar plant utilities•Plant Owners/Operators
What•Operational Monitoring•Performance Monitoring•Business KPIs
How•Technical Considerations•Architecture for Monitoring•Good Practices
© 2012 WIPRO LTD | WWW.WIPRO.COM12
Monitoring Architecture - Field
Considerations• How to collate data at a central place?
• How to handle link failure and data loss?
• What is the right device for data management – logger, RTU, SCADA?
• What is the right frequency of data collection?
Good Practices• Use Modbus for rooftop and small plants. Use
wireless for plants spread across
• Attach a local PC for data buffering.
• Rooftop – data logger, small plants – RTU, larger plants – SCADA for local control
• Rooftop – 5 mins, small plants – 1 min, substations – 10 sec.
© 2012 WIPRO LTD | WWW.WIPRO.COM13
Monitoring Architecture - Center
Considerations• How to integrate plants with different
technologies and vendors?
• How to ensure real time data acquisition at very high rates?
• How to combine real time and enterprise data for reports and dashboard?
Good Practices• Protocol independent device layer to integrate
with any field situation
• Use SCADA for data acquisition and real time screen definition, including control actions
• Use collaboration tools for information exchange with field crew
• Integrate the solution with enterprise applications to gain efficiency
• Use portal mashup to bring together real time and analytic information.
Device Integration
Modbus
XMLDNP3 IEC 104
OPC
SCADA
Historian
Enterprise Integration
Enterprise AppsEnterpris
e AppsEnterprise AppsEnterpris
e AppsR
eal Tim
e D
ashboard
Enterprise Security
Collaboratio
n
© 2012 WIPRO LTD | WWW.WIPRO.COM14
Common Considerations
Technology Areas
Scalability
ScalabilityReliability
ReliabilityNetwork Choice
Network ChoiceCyber Security
Cyber SecurityAccessibility
AccessibilityMobilityMobilityScalability
ScalabilityReliability
Reliability
Network Choice
Network Choice
Cyber Security
Cyber Security
Accessibility
Accessibility
MobilityMobilityScalability
ScalabilityReliability
Reliability
Network Choice
Network Choice
Cyber Security
Cyber Security
AccessibilityAccessibility
MobilityMobilityScalabilityScalabilityReliabili
tyReliability
Network ChoiceNetwork Choice
Cyber SecurityCyber Security
AccessibilityAccessibility
MobilityMobilityScalabilityScalability
ReliabilityReliabilityNetwork
ChoiceNetwork ChoiceCyber
SecurityCyber SecurityAccessi
bilityAccessibilityMobilityMobility
ScalabilityReliability
Network ChoiceCyber Security
AccessibilityMobility
Seamless scaling with increase in plants
Handle link fails, data losses
Wired, Wireless,VSAT – assess suitability
Implement CIP standards from
NERC
Must be web accessible. Share data
with Stakeholders
Dashboard on handheld. Crew enablement
© 2012 WIPRO LTD | WWW.WIPRO.COM15
Deployment Approach
- Scalability- Security- Accessibility- Pay per use
© 2012 WIPRO LTD | WWW.WIPRO.COM16
Demo Dashboard and RoadmapIT and Automation Scenarios
© 2012 WIPRO LTD | WWW.WIPRO.COM17
Demo Dashboard
© 2012 WIPRO LTD | WWW.WIPRO.COM18
The Maturity Curve
Passive ViewingDelayed
Plant data
Alerts
Offline actions
Operations MonitoringNear real time
Control actions
Prediction and tracking
Long term analytics
Performance monitoring
Dedicated team
Integrated OperationsCause and action
Integrated maintenance and inventory
Manage commercial performance
As an Utility- Integrated
operation and back-office
- Utilize KPIs from utilities
© 2012 WIPRO LTD | WWW.WIPRO.COM19
Abhinav Jain
Domain Consultant
Power Generation and Renewable