CellBOX-H/HYDRANT Energy-saving data logger for water supply network CellBOX-H/Hydrant is an advanced, fully autonomous, programmable multi-channel microprocessor logger, designed for measurement and recording of water supply network parameters, with GSM (SMS / GPRS / EDGE) data transmission to the parental system. It combines the benefits of new technologies for data collecting and processing with the latest methods of data transmission through wireless networks. It enables real-time measurement and logging of pressure, temperature, battery level, any three physical quantities (processed to a standard 4÷20[mA] electrical signal), or the state of 3 bi-state inputs. GSM / GPRS transmission in public and private APNs Pressure measurement and registration Definable alarm thresholds with hysteresis Waterproof IP68 housing Easy mounting in hydrant fangs Compatible with SCADA systems

Upload: atmax

Post on 13-Aug-2015

155 views

Category:

Business


1 download

TRANSCRIPT

CellBOX-H/HYDRANTEnergy-saving data logger for water supply network

CellBOX-H/Hydrant is an advanced, fully autonomous, programmable multi-channel microprocessor logger, designed for measurement and recording of water supplynetwork parameters, with GSM (SMS / GPRS / EDGE) data transmission to theparental system. It combines the benefits of new technologies for data collecting and processing with the latest methods of data transmission through wireless networks.It enables real-time measurement and logging of pressure, temperature, batterylevel, any three physical quantities (processed to a standard 4÷20[mA] electricalsignal), or the state of 3 bi-state inputs.

GSM / GPRS transmission in public and

private APNs

Pressure measurement and registration

Definable alarm thresholds with

hysteresis

Waterproof IP68 housing

Easy mounting in hydrant fangs

Compatible with SCADA systems

We offer preconfigured SIM cards in the private APN cellbox.pland provide managementservice as well.We offer accessto the measurement datavia the Internet (any standard WWW browser).We ensure safety at everystage of transmission: IPSectunnels with 3DES encryptionfor connections with customers servers and SSL protocolfor WWW access.

Sample SCADA visualizations athttps://telemetria.net.plLogin: demo01 pass: demo01(login and password from“demo01” up to “demo09”)

CellBOX-H/Hydrant can analyze signals appearing at its inputs and take actionaccording to the deployed algorithm - for example, it may react to a sudden drop in pressure or flow increase. The built-in LCD screen displays the current status of all the measured parameters. For the version of the recorder equipped with an optional GSM / GPRS modem, in addition to local data recording, it is possible to automaticallytransfer measurement results to the dispatch center. Data transmission via GPRS can be carried out in private APN networks which provide permanent IP numbers, or in public ones, where IP numbers are assigned in a dynamic way. The internal batterypack ensures operation of about 5 years, with data registration every 15 min. or less. To prolong its life in the GSM/GPRS mode (option with GSM/GPRS module) it isrecommended that an external power supply should be used.Professional telemetry and monitoring systems, remote network diagnostics (gradualregion testing, sectorization), detection and localization of bursts – all of the above can be built on the basis of the CellBOX-H/Hydrant. The logged data (e.g. minimum night flow) can be used in water loss analyses. Easy mounting in underground hydrant fangs makes CellBOX-H/Hydrant to be the perfect solution at measurement campaigns,e.g. for calibration and verification of mathematic models of water supply networks. The device could be used also at intervention control measurements for a single,ad hoc registration of parameters of a water network.The device can also be used in the process of selection of appropriate measuringdevices, e.g. water meters.CellBOX-H/Hydrant is adapted for operation with all water meters equipped with pulsetransmitters, electromagnetic and ultrasonic flow meters, and all measurementdevices by renowned companies.

Owing to its compact design and rich configuration options, CellBOX-H/Hydrant has gained a reputation of an excellent tool facilitating the daily operation of complex water supply networks. Waterproof IP68 housing made of stainless steel and luminium provides application flexibility, enabling easy mounting direct in normalized underground hydrant fangs or in any measuring point, thanks to additional 2” threaded coupling. Thanks to internal non-volatile FLASH memory and built-in pressure (optional) and temperature transducers, device performs measurements and registration autonomously.

Analog Inputs 3 universal inputs, resolution: 12bit current inputs 4÷20[mA]; input resistance

100Ω, accuracy 0,1% Any scale, any description or unit

Digital inputs 3 configurable inputs – universal with

common ground; average reaction time: 10ms

event-type (minimal interval of event duration 1s)

counter-type (e.g. for operation with water meter pulse transmitter, fmax=60Hz)

Built-in measurement transducers Temperature, range: -25÷70 [°C]; accuracy

±2 °C Pressure, range: 0÷16 [bar]; accuracy 0,5%

(short-time overload max 32bar)

Connections RS232 interface Analog and digital inputs connectors (cables

with IP68 glands) External power supply Additional 2” threaded coupling Optional universal quick coupler Antenna connector (optional)

Communication protocols Biatel SA custom protocol Optional MODBUS protocol or any other on

request (protocol description required) OPC server

Logger functionality Cyclic or linear data logging Simultaneous logging of 16 parameters out

of 32 available measured quantities GSM: SMS, GPRS, or optional EDGE data

transmission Internal memory capacity: up to 160 000

measurement results Programmable logging interval of 1s to 31

days with 1s resolution Public or private APN data transmission

Configuration capability LCD display of any of the measured parameters Configurable display of descriptions and units of parameters on the

LCD CSQ measurement and visualization supporting optimal antenna

setting Restore to factory default settings function Full device and software identification Built-in bootloader for remote software update

Features 16-characters LCD display Internal real-time clock Simultaneous logging and memory reading 8 definable alarm thresholds with hysteresis Dual band GSM modem 900/1800MHz (optional) Independent alarm thresholds definition on analog and digital inputs Detection of external power supply and RS232 port activity Internal battery power level control

Modes of operation TCP Server - server forces sessions with the device (modem activity

required) TCP Client - device maintains connection with server SMS, optional UDP, CSD Constant or periodic transmission according to a given schedule Alarm start/stop sends SMS to up to 4 defined phone numbers

Schedules Tasks performed on defined days of the week or month Programmable task starting time Interval of 1 second up Separate schedules for logging, transmission, analog or digital

measurements Flow rate calculation Alarm checkup

Technical data Storage temperature: –40÷80 [°C] Operating temperature: –25÷70 [°C] (–20÷55[°C] with GSM modem

active) Stainless steel and aluminium IP68 housing adapted to mounting in

hydrant fangs Dimensions: 150mm height, 110mm diameter Weight: approx. 2,1kg

Power supply Internal battery (operation time of up to 5 years, depending on

configuration mode) External rechargeable accumulator (used for GSM transmission) External power supply connection as an option