    Objects

    Mastering engineering commissioning flow

    Familiarizing with patrol flow and operations

    of patrol items

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    3/54

    Content

    Engineering commissioning flow

    Patrol Guide

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    4/54

    Engineering Commissioning Flow

    1. Project Survey2. Engineering

    Installation Design

    3. 2nd Environmental

    Acceptance Test4. Unpacking

    Inspection

    5. Hardware Installation

    6. Checking and Poweron

    7. SoftwareInstallation

    8. Preliminary

    Acceptance Test

    9. Handover

    10. Cutover

    11. Trial Running

    12. Final Acceptance

    Test

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    5/54

    Contents

    Engineering commissioning flow

    Patrol Guide

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    6/54

    Checking Items for Patrol Guide

    Networking, indicator, clock, network equipment,

    background system, service version, alarm, call

    quality test, hardware implementation quality,

    software installation CD check

    Billing check

    Network situation check

    Configuration data check

    Performance analysis and system test

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    7/54

    Basic Running Situation Check--Hardware

    and Networking Check

    Board debugging IP address calculation: A.B.C.D

    A = 128

    B = Office ID*16 + (Rack No. 1)

    C = (Shelf No. 1) * 32 + Slot No. D= (CPU No. 1) * 8 + 1

    OMP address is fixed:

    Active: 128.0.31.1

    Standby: 128.0.31.9

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    8/54

    Basic Running Situation Check--IGPS

    Indicator Status Check

    RUN (green indicator): It flashes during proper

    running (Flash once every 0.5 seconds)

    ALM (red indicator): It is off during proper running, it

    is on when the board is faulty. ACT (green indicator): It is on when the board is

    active; it is off when the board is standby.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    9/54

    Basic Running Situation Check--UPDS

    Indicator Status Check

    RUN (green indicator): It flashes during proper

    running (Flash once every 0.5 seconds)

    ALM (red indicator): It is off during proper running, it

    is on when the board is faulty. ACT (green indicator): It is on when the board is

    active; it is off when the board is standby.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    10/54

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    11/54

    Basic Running Situation Check--DOMP

    Indicator Status Check

    There two CPUs for each board

    RUN1 and RUN2 (green indicator): It flashes during

    proper running (Flash once every 0.5 seconds)

    ALM1 and ALM2 (red indicator): It is off duringproper running, it is on when the board is faulty.

    ACT1 and ACT2 (green indicator): It is on when the

    CPU is active; it is off when the CPU is standby.

    If it is OMP module, then omc2 indicator flashesquickly.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    12/54

    Basic Running Situation Check--DSMP

    Indicator Status Check

    There two CPUs for each board

    RUN1 and RUN2 (green indicator): It flashes during

    proper running (Flash once every 0.5 seconds)

    ALM1 and ALM2 (red indicator): It is off duringproper running, it is on when the board is faulty.

    ACT1 and ACT2 (green indicator): It is on when the

    CPU is active; it is off when the CPU is standby.

    If it is OMP module, then omc2 indicator flashesquickly.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    13/54

    Basic Running Situation Check--DUIM

    Indicator Status Check

    RUN (green indicator): It flashes during proper

    running (Flash once every 0.5 seconds)

    ALM (red indicator): It is off during proper running, it

    is on when the board is faulty. ACT (green indicator): It is on when the board is

    active; it is off when the board is standby.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    14/54

    Basic Running Situation Check--Foreground

    Board Log Check

    1. Open PDS OMC File Management window as

    shown below.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    15/54

    Basic Running Situation Check--Foreground

    Board Log Check

    2. Right-click File Management, and choose Board

    Maintenance as shown below.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    16/54

    Basic Running Situation Check--Foreground

    Board Log Check

    3. Input Unit Name, e.g., OMP; input Unit Type, e.g.,

    OMP; choose 65535 as Unit ID. Do not modify

    other values.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    17/54

    Basic Running Situation Check--Foreground

    Board Log Check

    4. In File Management, there is added OMP unit

    node. After clicking OMP, the DOC0 and IDE0

    folder appears, as shown below.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    18/54

    Basic Running Situation Check--Foreground

    Board Log Check

    5. Choose DOC0, and the corresponding files and

    folders under DOC0 appear on the right pane.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    19/54

    Basic Running Situation Check--Foreground

    Board Log Check

    6. Right-click Exc_pp.txt, and choose Copy, as

    shown below.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    20/54

    Basic Running Situation Check--Foreground

    Board Log Check

    7. From File Management on the left, choose the local node,

    and choose the disk array for saving it.

    8. On the blank space on the right, right-click to choose Paste

    and complete file copying, as shown below.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    21/54

    Basic Running Situation Check--Foreground

    Board Log Check

    9. Logs under /IDE0/EXCINFO on each board are as

    follows.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    22/54

    Basic Running Situation Check--Clock Check

    On the Clock Management interface, query whether the

    current clock of foreground OMP is correct. If it is incorrect,

    please configure the current clock of OMP during safe hour as

    shown below.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    23/54

    Basic Running Situation Check--Alarm Box

    Check

    Check whether the sound alarming function of the

    alarm box has been enabled; it is not allowed to be

    set as mute status. The alarm information should

    be reported to the alarm box, and the alarm short

    messages can be normally sent to the mobile

    phones of the maintenance engineers.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    24/54

    Basic Running Situation Check--Equipment

    Room Environment Check

    Check the temperature, humidity, and dust in the

    equipment room. Check whether the fans on central

    rack are running normally.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    25/54

    Basic Running Situation Check--Network

    Equipment Check

    Switch Check

    Checking methods:

    1. Switch indicator is flashing normally;

    2. The indicator on each port connecting to networkcable is flashing normally;

    3. Whether the cascading port has been configured;

    4. Whether there are 3 cascading cables;

    5. Whether the network cable from other system is

    directly connected to DSS system.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    26/54

    Basic Running Situation Check--Network

    Equipment Check

    Router and Firewall Check

    Checking methods:

    1. RUN indicator is flashing normally;

    2. The indicator on each port connecting to networkcable is flashing normally.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    27/54

    Basic Running Situation Check--Background

    System Check

    Windows System Check

    System patch check: Query the attribute on My

    Computer, and Windows 2000 should install SP4 or

    above.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    28/54

    Basic Running Situation Check--Background

    System Check

    SQL Server2000 Patch Check

    Open Enterprise Management, and query SQL

    Server attribute. In the figure below, the red circle

    indicates SQL Server patch No.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    29/54

    Basic Running Situation Check--Background

    System Check

    RPC Patch Check In Start > Run, input regedit to enter the registry table; Open

    HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Updates\Wind

    ows 2000 ; If the item in red cannot be found in the registry table,

    please install Microsoft RPC patch.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    30/54

    Basic Running Situation Check--Background

    System Check

    Sasser.wormPatch Check1. In Start> Run, input regedit to enter the registry table.2. Open HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Updates\Windows

    2000.

    If the item in red cannot be found in the registry table, please install Microsoft

    sasser.worm patch.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    31/54

    Basic Running Situation Check--Background

    System Check

    Virtual Memory Check Query the attribute ofMy computer, and click

    Advanced > Performance > options > Modify. The

    virtual memory should be set as 1.5 times of the

    physical memory, and it should not exceed 2G.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    32/54

    Basic Running Situation Check--Background

    System Check

    Query & Record SQL Minimum Query Memory Run SQL Server Enterprise Manager, and query the

    attributes of SQL Server. The minimum query

    memory should be set to 2048.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    33/54

    Basic Running Situation Check--Background

    System Check

    Installation of Unauthorized Software Check

    In the system, except for the operating system,

    database system, version software, anti-virus

    software and other mandatory software, other

    irrelevant software shall not be installed.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    34/54

    Basic Running Situation Check--Background

    System Check

    Mini-computer System Check

    Solaris

    1. Check system version

    2. Check disk space3. Check network configuration

    4. Check the local mirroring

    5. Check the booting disk information (Performed

    during safe hours)

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    35/54

    Basic Running Situation Check--Background

    System Check

    Mini-computer System Check

    Aix

    1. Check system version

    2. Check disk space3. Check network configuration

    4. Execute errpt a to check system error (used only

    for IBM mini-computer).

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    36/54

    Basic Running Situation Check--Background

    System Check

    Oracle Database Check

    1. Oracle version

    2. SGA size

    3. Table space4. oradism attribute

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    37/54

    Basic Running Situation Check--Background

    System Check

    Cluster Software Check

    VCS

    1. Check MEM module

    2. Check heartbeat3. Check the running status

    4. Cluster changeover test

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    38/54

    Basic Running Situation Check--Background

    System Check

    Cluster Software Check

    HACMP

    1. Check HACMP status

    2. Cluster changeover test

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    39/54

    Basic Running Situation Check--Background

    System Check

    Cluster Software Check

    TurboHA

    1. Display cluster and service status

    2. Cluster resource changeover

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    40/54

    Basic Running Situation Check--Background

    System Check

    Auto-Start Setting of PHR Single-computer and

    DAS Single-computer Check

    1. Verifying restarting of PHR single computer (solaris

    system).

    2. Verifying restarting of DAS single computer.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    41/54

    Basic Running Situation Check--Service

    Version Check

    PDS Version Check

    PDS Foreground Version Check:

    In 3GPlatform Version Management Version Query,

    check whether all the version files on OMP are

    consistent with the background version.

    PDS boot Version Check

    Telnet to the foreground board, run TestMenu, and

    record the running result.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    42/54

    Basic Running Situation Check--Service

    Version Check

    PHR Version Check

    PHR Service Version Check

    Log onto PHR server as root user, and enter PHR

    installation directory/phrsys/zte.corp/zxphr. Check the

    version No. in zxphr.cfg, in which Version = is thecurrent PHR version No. The command is as below:

    #cd /phrsys/zte.corp/zxphr

    #more zxphr.cfg

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    43/54

    Basic Running Situation Check--Service

    Version Check

    PHR Version Check

    PHR Database Version Check

    Log onto the agent console, and select Help > About

    menu. In the About This Product window, press shift

    and click the ZTE icon, to display the complete versionNo. .

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    44/54

    Basic Running Situation Check--Service

    Version Check

    DAS Version Check

    Log onto the management console, and choose the

    menu System > System Information to enter the

    tab of system information, to check the major version

    No. Press shift+F5 to check the build version No. .

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    45/54

    Basic Running Situation Check--Alarm Check

    PHR Alarm

    In OMC fault management, query the current PHR

    real-time alarms, and analyze the alarms.

    PDS Alarm

    In OMC fault management, query the current PDS

    real-time alarms, and analyze the alarms.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    46/54

    Basic Running Situation Check--Call Test

    Private call: Use the Gota mobile terminal to

    perform the private call tests.

    Group call: Use the Gota mobile terminal to perform

    the group call tests.

    DAC Initiates the Private Call: The dispatcher logs

    onto the dispatching console, and initiates the

    private call.

    DAC Initiates the Group Call: The dispatcher logs

    onto the dispatching console, and initiates the

    group call.

    Call the Dispatching Console: The mobile terminal

    calls the number of dispatching console.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    47/54

    Basic Running Situation Check--Hardware

    Implementation Quality Check

    Switch cascading: Make the cascading according to the requirement of

    dual-computer structure.

    Rack grounding:

    The grounding should comply with the requirement.

    Converter (4-to-1, 8-to-1):

    The interface can be changed over normally. After

    changeover, perform operations on the host.

    Label on Ethernet cable:

    The label should be pasted according to therequirement, and should be clear.

    Label on power cable:

    The label should be pasted according to the

    requirement, and should be clear.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    48/54

    Accounting Check

    FTP CDR Check

    Check whether the billing files under/billhand/ftp

    have been collected by the billing center.

    BILLSAVE CDR Check

    Check whether the billing files have been backed up

    under/billhand/billsave.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    49/54

    Network Situation Check

    Switch Configuration Check

    Check it as per the specified specifications.

    Analysis of Switch Logs

    Collect the switch logs, and analyze whetherthere is any abnormal log.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    50/54

    Data Check

    PDS Configuration Data Check

    Check whether the configuration of PDS is

    consistent with the plan and true.

    PHR Configuration Data Check

    1. Check IP address configuration.

    2. Check route configuration.

    3. Check listener.ora and tnsnames.ora files

    configuration.

    4. Check ipmp.targets files configuration under Solaris

    system.

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    51/54

    Data Check--DAS Configuration Data Check

    Check the OS version of DAS server: Check OS Time & Timezone

    Check whether the default gateway is configured correctly

    Check whether NAT IP is configured correctly

    Check IP Address of PHR Database

    tomcat Port No. Check whether positioning service is supported

    Confirm whether the onsite positioning server can be used

    normally

    Check configuration of DAS and PDS Parameters

    Check SMS related configuration

    Check SMS and SMSC interconnection related configuration

    Check configuration of user sending short message to

    dispatching console

    Check PC environment detection tool related configuration

    Check timer configuration

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    52/54

    OMC Check

    Check whether the actual timer, date and timezone on OMC

    server is consistent with local time

    Check whether the daylight saving time is configured

    according to the local plan

    Check the space size for alarm backup directory and logbackup directory

    Check the DB resource

    Scheduled Task Setting in DB Table Set

    External Clock Source Configuration

    PDS SNTP Configuration

    Per-defined Task of Performance Statistics

    Alarm Box Configuration

    CORBA Configuration

  • 7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54

    53/54

    Performance Analysis and System Test

    PDS performance statistics analysis

    PDS foreground board changeover test

    PHR disaster recovery single computer

    availability test