catalogue page: yvwa water-cooled variable speed screw chiller · 68 features our newest...
TRANSCRIPT
68
FeaturesOur newest water-cooled chiller offers the following benefits:
Premium efficiencyThe YVWA reduces operating expenses with the application of a standard variable speed drive.
Application flexibilityTailor and tune flexilibilty makes the YVWA ideal for any application from thermal storage to heat pump duty.
Enhanced sustainabilityAchieved through high efficiency operation and low refrigerant charges.
Product confidenceImprove your peace of mind knowing our experience stands behind every chiller.
Reduce refrigerant charges by up to 15% beyond traditoinal chiller designs with the YVWA’s falling film evaporator design.
Phot
o co
urte
sy o
f the
LTCM
lab
of th
e Ec
ole
Polyt
echn
ique
Féd
érale
de
Laus
anne
, Sw
itzer
land
The YVWA chiller can efficiently handle the high condenser pressure required for dry cooling.
Phot
o co
urte
sy o
f Balt
imor
e Ai
r Coi
l.
Options / Accessories• BMS Interfacing options • Different options of tubes and nozzle arrangements for the heat exchangers.
• Dual pressure relief valve • Several options for flow switches • Thermal insulation options • Anti-vibration mounts options
YVWAWater-cooled variable speed screw chillerCooling capacities from 435 kW to 1070 kW (Extended Range up to 1400 kW available soon)At Eurovent Standard Conditions this equipment meets A Class energy efficiency levels.
YORK® AIR-CONDITIONING PRODUCTS
69
Nominal capacityModel YVWABBBBFX YVWACDCDFX YVWABBBBGX YVWACDCDGX YVWAM2M2EE YVWAM2MCEECooling capacity (kW) 451 525 575 650 700 750
EER 100% 5 5.41 4.72 5.14 4.81 5.13
ESEER 6.99 7.42 7.09 7.66 6.79 7.17
Model YVWAMBMCEE YVWAMDMCFE YVWAMDMDFE YVWAMDMEFE YVWAMEMEFF YVWANENEFFCooling capacity (kW) 800 850 900 950 1000 1070
EER 100% 5.3 5.39 5.35 5.32 5.3 5.33
ESEER 7.41 7.51 7.57 7.62 7.55 7.57
Cooling Capacity at Eurovent Conditions, entering / leaving chilled water temperature 12 / 7 °C condenser water 30 / 35 °CCapacities are rounded nominal values across the product range.The taylor and tune models allow over 7000 component combinations in stepless selection capacities / operating conditions.Specific selections may achieve an operating envelope of -10 to + 16 °C evaporator liquid and from 18 to 65 °C condenser liquid.Models are using selected components from the quick ship program.
Technical dataModel YVWABBBBFX YVWACDCDFX YVWABBBBGX YVWACDCDGX YVWAM2M2EE YVWAM2MCEECompressors / Circuite(s) 1 1 1 1 2 2
Dimensions
Length mm 3110 3571 3110 3720 4390 4390
Width mm 1413 1413 1413 1413 1405 1405
Height mm 1846 1846 1846 1846 1824 1824
Operating weight (kg) 3692 4169 3822 4299 5701 5884
Refrigerant charge (kg) 127 153 137 163 250 250
Model YVWAMBMCEE YVWAMDMCFE YVWAMDMDFE YVWAMDMEFE YVWAMEMEFF YVWANENEFFCompressors / Circuite(s) 2 2 2 2 2 2
Dimensions
Length mm 4390 4390 4390 4390 4390 5000
Width mm 1405 1405 1405 1405 1405 1405
Height mm 1824 1824 1824 1824 1824 1824
Operating weight (kg) 6032 6265 6315 6421 6540 7052
Refrigerant charge (kg) 250 255 255 255 260 300
The YVWA chiller delivers superior energy performance at all operating hours.
YVWA Efficiency vs. Ordinary Chiller YVWA Energy Cost vs. Ordinary Chiller
An investment in an optimized YVWA chiller reduces energy costs by 25%.
YVWA Efficiency vs. Ordinary Chiller
Ordinary ChillerYVWA Chiller
0
5
10
15
Chi
ller
Effici
ency
(EE
R)
3
4
5
6
7
8
9
10
Chiller Load (%)
ECWT (°C)
ECWT = Entering Condenser Water Temperature
10 20 3040
5060
7080
90100
15.6 17.2 18.820.4
22.023.6
25.226.8
28.430.0
Ann
ual H
ours
(%
)
YVWA Energy Cost vs. Ordinary Chiller
1 2 3 4 5 67
89
10Years
-
50,000
100 ,000
150,000
200,000
250,000
YVWA Chiller
Ordinary Chiller
Note: 3,500 operating hours, 0.10 EUR/kWh energy rate, 800 kW design cooling load
Water-cooled variable speed screw chillerYVWA
Manufacturer reserves the rights to change specifications without prior notice.
70
YVWA B models
YVWA C models
Dimensions and hydraulic connections
YORK® AIR-CONDITIONING PRODUCTS
71
YVWA N models
YVWA M models
Dimensions and hydraulic connections