catalogo de bandeja electrica

24
LOAD DEPTH RAIL HEIGHT BOTTOM FLANGE IN FLANGE OUT LADDER FLANGE IN FLANGE IN VENTILATED/TROUGH CORRUGATED BOTTOM CABLE TRAY SYSTEM NUMBERS B417 B418 B419 1D81 1D83 1D70 A453 A454 A455 B453 B454 B455 A462 A463 A464 B456 B457 A402 A412 A451 A452 B451 B452 A460 A461 RAIL HEIGHT LOAD DEPTH NEMA CLASS CATALOG PAGE STEEL CABLE TRAYS STEEL CABLE TRAYS HEAVY DUTY I-BEAM SIDE RAILS 46 47 48 44 45 4" 3" 2E71 2E72 B638 B639 2771 2772 B518 B519 B618 B619 2773 2774 1E01 1E49 1F56 1F69 1780 1779 A551 A552 A651 A652 A751 A752 B551 B552 B651 B652 B751 B752 A560 A561 A660 A661 A760 A761 1E46 1E54 1F46 1F54 1756 1754 A554 A555 A654 A655 A754 A755 B554 B555 B654 B655 B754 B755 A562 A563 A662 A663 A762 A763 49 50 53 54 57 58 51 52 55 56 59 60 5" 6" 7" 4" 5" 6" A456 A457 Hot-Dip Galvanized After Fabrication Hot-Dip Galvanized After Fabrication Hot-Dip Galvanized After Fabrication Hot-Dip Galvanized After Fabrication Hot-Dip Galvanized After Fabrication Hot-Dip Galvanized After Fabrication Hot-Dip Galvanized After Fabrication Mill Galvanized (Pre-Galv.) Mill Galvanized (Pre-Galv.) Mill Galvanized (Pre-Galv.) 1D80 1D82 1D69 1E71 1E72 A638 A639 1771 1772 1E45 1E53 1F45 1F53 1755 1753 B462 B463 B464 B460 B461 B560 B561 B660 B661 B760 B761 B562 B563 B662 B663 B762 B763 SIDE RAIL 20C+ 20C+ 20C+ 61 62 63 LADDER VENTILATED / TROUGH 1952 1953 1954 SOLID BOTTOM 8" 6" 1972 1973 1962 1963 Contact PW 10" 4" 20A,16B 20B,16C 20C 20B,16C 20C 12B 12C,16A 20B,16C 20C 12B 12C,16A 12B 12C,16A 12B 12C,16A 20B,16C 20C Metallic Cable Tray and Channel 42 PW Industries, Inc. M C T C ETALLIC ABLE RAY AND HANNEL S S S TEEL TRAIGHT ECTIONS 8A 8B 8C 12 ft. SAFE WORKING LOAD 50 lbs/ft 75 lbs/ft 100 lbs/ft 12A 12B 12C 8 ft. 16A 16B 16C 20 ft. 20A 20B 20C 16 ft. SUPPORT SPAN NEMA CLASS NEMA Class: Load/Span rating for the load carrying capability of the tray system, based on a 1.5 safety factor and tested per NEMA Std. VE1. See SAFE LOAD data on the following page to compare tray performance across various support spans. Tray System Number: System Number Identifies a specific PW cable tray design including the material, type, rail height, style, bottom, and NEMA Load Class. The is used in the catalog numbering system for straight sections, fittings, and accessories. Refer to the catalog pages shown in the chart for detailed information on each cable tray system. Rail Height: Nominal overall height of the tray side rails. Tray Types: The ladder, ventilated/trough, and corrugated bottom cable tray systems shown in this chart are standard PW designs, in accordance with NEMA Std. VE1 guidelines. See pages 6-7 for construction details on standard and alternate PW cable tray designs. Load Depth: Nominal interior depth of the cable tray that is available for fill. The nominal height and depth are defined by NEMA Std. VE1 to be within 3/8" of the actual exact dimension. System numbers efer to the appropriate catalog pages are shown for each type of standard steel cable tray. For detailed information and part numbers for specific tray systems, please r . STEEL CABLE TRAY SYSTEMS PW INDUSTRIES.COM Contact PW

Upload: kancrillo

Post on 22-Dec-2015

268 views

Category:

Documents


1 download

DESCRIPTION

BANDEJAS ELECTRICAS - DIMENSIONES, ESPECIFICACIONES, ETC

TRANSCRIPT

Page 1: Catalogo de Bandeja Electrica

LOAD

DEPTHRAIL

HEIGHT BOTTOM

FLANGE IN FLANGE OUT

LADDER

FLANGE IN FLANGE IN

VENTILATED/TROUGH CORRUGATED BOTTOM

CABLE TRAY SYSTEM NUMBERS

B417

B418

B419

1D81

1D83

1D70

A453

A454

A455

B453

B454

B455

A462

A463

A464

B456

B457

A402

A412

A451

A452

B451

B452

A460

A461

RAIL

HEIGHT

LOAD

DEPTH

NEMA

CLASS

CATALOG

PAGE

STEEL CABLE TRAYS

STEEL CABLE TRAYSHEAVY DUTY

I-BEAM SIDE RAILS

46

47

48

44

45

4" 3"

2E71

2E72

B638

B639

2771

2772

B518

B519

B618

B619

2773

2774

1E01

1E49

1F56

1F69

1780

1779

A551

A552

A651

A652

A751

A752

B551

B552

B651

B652

B751

B752

A560

A561

A660

A661

A760

A761

1E46

1E54

1F46

1F54

1756

1754

A554

A555

A654

A655

A754

A755

B554

B555

B654

B655

B754

B755

A562

A563

A662

A663

A762

A763

49

50

53

54

57

58

51

52

55

56

59

60

5"

6"

7"

4"

5"

6"

A456

A457

Hot-Dip

Galvanized

After Fabrication

Hot-Dip Galvanized

After Fabrication

Hot-Dip Galvanized

After Fabrication

Hot-Dip Galvanized

After Fabrication

Hot-Dip

Galvanized

After Fabrication

Hot-Dip

Galvanized

After Fabrication

Hot-Dip

Galvanized

After Fabrication

Mill

Galvanized

(Pre-Galv.)

Mill

Galvanized

(Pre-Galv.)

Mill

Galvanized

(Pre-Galv.)

1D80

1D82

1D69

1E71

1E72

A638

A639

1771

1772

1E45

1E53

1F45

1F53

1755

1753

B462

B463

B464

B460

B461

B560

B561

B660

B661

B760

B761

B562

B563

B662

B663

B762

B763

SIDE RAIL

20C+

20C+

20C+

61

62

63

LADDER VENTILATED / TROUGH

1952

1953

1954

SOLID BOTTOM

8" 6"1972

1973

1962

1963

Contact PW10" 4"

20A,16B

20B,16C

20C

20B,16C

20C

12B

12C,16A

20B,16C

20C

12B

12C,16A

12B

12C,16A

12B

12C,16A

20B,16C

20C

Metallic Cable Tray and Channel42 PW Industries, Inc.

MC

TC

ETA

LLIC

ABLE

RAY

AN

DH

AN

NEL

S S STEEL TRAIGHT ECTIONS

8A

8B

8C

12 ft.

SAFE

WORKING

LOAD

50 lbs/ft

75 lbs/ft

100 lbs/ft

12A

12B

12C

8 ft.

16A

16B

16C

20 ft.

20A

20B

20C

16 ft.

SUPPORT SPAN

NEMA CLASS

NEMA Class: Load/Span rating for the load carryingcapability of the tray system, based on a 1.5 safetyfactor and tested per NEMA Std. VE1. See SAFELOAD data on the following page to compare trayperformance across various support spans.

Tray System Number:

System Number

Identifies a specific PW cable tray design includingthe material, type, rail height, style, bottom, and NEMA Load Class. The

is used in the catalog numbering system for straightsections, fittings, and accessories. Refer to the catalog pages shown in thechart for detailed information on each cable tray system.

Rail Height: Nominal overall height of the tray side rails.

Tray Types: The ladder, ventilated/trough, and corrugated bottom cable traysystems shown in this chart are standard PW designs, in accordance withNEMA Std. VE1 guidelines. See pages 6-7 for construction details onstandard and alternate PW cable tray designs.

Load Depth: Nominal interior depth of the cable traythat is available for fill. The nominal height and depth aredefined by NEMA Std. VE1 to be within 3/8" of the actualexact dimension.

System numbers

efer to the appropriate catalog pages

are shown for each type of standard steel cabletray. For detailed information and part numbers for specific traysystems, please r .

STEELCABLE TRAY SYSTEMS

PWINDUSTRIES.COM

Contact PW

Page 2: Catalogo de Bandeja Electrica

STEELCABLE TRAY SYSTEMS

RAIL

HEIGHT

LOAD

DEPTH

NEMA

CLASS

CATALOG

PAGE

SAFE LOAD DATA (lbs/ft)

4" 3" 20A,16B

20B,16C

20C

5" 4"20B,16C

20C

6" 5"

12B

12C,16A

20B,16C

20C

7" 6"

475

625

844 304

400

211

278

155

204

119

156

76

100

61

81

50

66

300

400

525

719

933 336

460

233

319

171

235

131

180

104

142

84

115

68

93

53

73

316

420

338

488

625

600

867

216

312

400

150

217

278

110

159

204

84

122

156

67

96

123

54

78

100

63

81

52

66

169

225

108

144

75

100 71 52

94

123

178

236

114

151

79

105 74 55

300

400

169

225

108

144

75

100

53

71 52

468

719

833 208

319

153

235

117

180

93

142

50

76

300

460

75

115

61

93

6

SUPPORT SPAN (feet)

8 10 12 14 16 18 20 22 24 26 28 30

12B

12C,16A

332

444

187

250

120

160

83

111 78 58

12B

12C,16A

STEEL CABLE TRAYS

46

47

48

44

45

49

50

53

54

57

58

51

52

55

56

59

60

8" 6"20C+

20C+

20C+10" 4"

250

444

167

298

202

360

141

250

120

213

103

184

90

160

67

120

58

103

44

78

367367367367367367367367367 268 212 164 124

SUPPORT SPAN (feet)

20 24 26 28 30 36 40 45 50

61

62

63

HEAVY DUTY

STEEL CABLE TRAYSWITH I-BEAM SIDE RAILS

12B

12C,16A

20B,16C

20C

22 32 34 38

Metallic Cable Tray and Channel 43PW Industries, Inc.

MC

TC

ETA

LLICA

BLE

RAY

AN

DH

AN

NEL

S S STEEL TRAIGHT ECTIONS

Safe Load:

To convert safe load data to reflect a safety factor of 2.0, multiply theload shown by 0.75.

Metric Units:

Deflection:

Tray Lengths:

Heavy Duty Trays:

Allowable cable load in lbs per linear footased on simple beam type supports with a safety factor

of 1.5, per Safe load data is based on theperformance of the tray side rails only. For heavy loads on shortspans, it is possible that the tray bottom capabilities will be less thanvalues shown for the tray side rails. Safe loads for tray rungs andbottoms are shown on pages

uniformlydistributed, b

NEMA Std. VE1.

To convert pounds per foot to kilograms per metermultiply by 1.488. To convert feet to meters multiply by 0.305.

See the load/deflection charts on pages 44-63 formid-span cable tray deflection information.

Standard tray lengths are 12' and 24'. 10', 20’and custom tray lengths are available. Contact PW for currentlead times on non-standard lengths.

Note: Straight tray lengths should be equal to or greater than thecable tray support spacing when installed, per NEMAStandards.

The availability of NEMA Class 20C+ traysmay be limited, and may require greater lead times. Contact PWfor current availability of all heavy duty tray systems.

137 - 140.

Visit to view this page in metric format and todownload technical data sheets for specific tray systems.

pwindustries.com

The Safe Load Data chart compares the performance of standard PW steelcable trays across a wide range of support spans. If a load is not shown for agiven span, that tray system is not recommended for use on the span.

PWINDUSTRIES.COM

Page 3: Catalogo de Bandeja Electrica

MATERIAL

LOAD

DEPTH

NEMA

CLASS

STEEL 12B

RAIL

HEIGHT

4" 3"

Metallic Cable Tray and Channel44 PW Industries, Inc.

MC

TC

ETA

LLIC

ABLE

RAY

AN

DH

AN

NEL

PWINDUSTRIES.COM

LADDER (Flange In)

Rungs are 1-1/4" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

Fittings for the tray systemson this page have 2" tangents.

FITTING SERIES

1

CLASSIFIEDAS AN EQUIPMENT

GROUNDING CONDUCTOR

PER N.E.C. 392.7

U.L. AREA AMPS

1000.40 in2

See pages 66-90 for fittingdimensions and part numbers.

UR

Straight Section Catalog Numbers:

Example: 0 9 - A 4 5 6 - 0 0 1 2 - 2 4 - S L

Tray System NumberBottom Type Length Width

06

09

12

18

- 6"

- 9"

- 12"

- 18"

24

30

36

- 24"

- 30"

- 36"

Rung Options

SL - With Slots†

Leave Blankfor No Slots

Special suffixesare also used

here to indicatealternate rung

designs.

(See page 133)

†Rung slots are .31" wide x .75" long on 1" centers. Slotted rungs are normally located every

second or third rung, alternating with solid rungs. Trays with slotted rungs only are also available.

S S STEEL TRAIGHT ECTIONS

4D02

B456

A456System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

LADDER (Flange Out)

Rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

A402System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

3"

1"

4"

VENTILATED/TROUGH

Rungs are 1-1/4" wide, spaced on 5"centers.

Available with slotted rungs for cable ties.

4D02

B451

A451System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

3

1"

4"1"8

4D02

B460

A460System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

3

1"

4"3"8

Supplied in pairs with cadmiumplated steel hardware.

See page 94 for upgradeoptions and more information.

Necessary connectors aresupplied with all trays. Extra

connectors for field cuts or sparesmust be ordered separately.

Catalog No. (pr.)

-1302-02(System No.)

TRAY CONNECTORS

SAFE

LOAD (lbs/ft)

DEFLECTION

(inches)

SUPPORTSPAN (feet)

Safe loads and deflections are based on simple beam supports and a safety factorof 1.5 per NEMA Standard VE1.

When cable trays are supported in continuous spans, the mid-span tray deflectionis approximately 60% of the values shown.

Load data is for the tray side rails only. See page137 for safe load limitations of tray rungs and bottoms.

SAFE LOAD AND DEFLECTION DATA

6 8 10 12

0010

0020

- 10'-0"

- 20'-0"

*0012 - 12'-0"

0024 - 24'-0"

*Standard

Length

This identifies the specifictray design and is used asa catalog number prefixfor straight sections,fittings, and accessories.

0.29 0.51 0.79 1.14

332 187 120 83

3

1"

4"1"8

CORRUGATED BOTTOM

Tray bottoms are 1/2" deep corrugated sheet with 7/8" wide support ribs

on 2" centers, solid (prefix SC) or ventilated (prefix VC) construction.

06

09

12

18

VT

- 6" Rung Spacing

- 9" Rung Spacing

- 12" Rung Spacing

- Ventilated/Trough

- 18" Rung Spacing

- Solid Corrugated Bottom

- Ventilated Corrugated Bottom

SC

VC

Page 4: Catalogo de Bandeja Electrica

MC

TC

ETA

LLICA

BLE

RAY

AN

DH

AN

NEL

Metallic Cable Tray and Channel 45PW Industries, Inc.

MC

TC

ETA

LLICA

BLE

RAY

AN

DH

AN

NEL

PWINDUSTRIES.COM

LADDER (Flange In)

Rungs are 1-1/4" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

Fittings for the tray systemson this page have 2" tangents.

FITTING SERIES

1

CLASSIFIEDAS AN EQUIPMENT

GROUNDING CONDUCTOR

PER N.E.C. 392.7

U.L. AREA AMPS

1000.40 in2

See pages 66-90 for fittingdimensions and part numbers.

UR

Straight Section Catalog Numbers:

Example: 0 9 - A 4 1 2 - 0 0 1 2 - 2 4 - S L

Tray System NumberBottom Type Length Width

06

09

12

18

- 6"

- 9"

- 12"

- 18"

24

30

36

- 24"

- 30"

- 36"

Rung Options

SL - With Slots†

Leave Blankfor No Slots

Special suffixesare also used

here to indicatealternate rung

designs.

(See page 133)

†Rung slots are .31" wide x .75" long on 1" centers. Slotted rungs are normally located every

second or third rung, alternating with solid rungs. Trays with slotted rungs only are also available.

S S STEEL TRAIGHT ECTIONS

4D02

B457

A457System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

LADDER (Flange Out)

Rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

A412System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

3"

1"

4"

VENTILATED/TROUGH

Rungs are 1-1/4" wide, spaced on 5"centers.

Available with slotted rungs for cable ties.

4D02

B452

A452System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

3

1"

4"1"8

4D02

B461

A461System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

3

1"

4"3"8

Supplied in pairs with cadmiumplated steel hardware.

See page 94 for upgradeoptions and more information.

Necessary connectors aresupplied with all trays. Extra

connectors for field cuts or sparesmust be ordered separately.

Catalog No. (pr.)

-1302-02(System No.)

TRAY CONNECTORS

0010

0020

- 10'-0"

- 20'-0"

*0012 - 12'-0"

0024 - 24'-0"

*Standard

Length

This identifies the specifictray design and is used asa catalog number prefixfor straight sections,fittings, and accessories.

MATERIAL

LOAD

DEPTH NEMA CLASS

STEEL 12C,16A

RAIL

HEIGHT

4" 3"

SAFE

LOAD (lbs/ft)

DEFLECTION

(inches)

SUPPORTSPAN (feet)

Safe loads and deflections are based on simple beam supports and a safety factorof 1.5 per NEMA Standard VE1.

When cable trays are supported in continuous spans, the mid-span tray deflectionis approximately 60% of the values shown.

Load data is for the tray side rails only. See page137 for safe load limitations of tray rungs and bottoms.

SAFE LOAD AND DEFLECTION DATA

1086 12 14 16

0.31 0.55 0.86 1.24 1.61 2.06

444 250 160 111 78 58

3

1"

4"1"8

CORRUGATED BOTTOM

Tray bottoms are 1/2" deep corrugated sheet with 7/8" wide support ribs

on 2" centers, solid (prefix SC) or ventilated (prefix VC) construction.

06

09

12

18

VT

- 6" Rung Spacing

- 9" Rung Spacing

- 12" Rung Spacing

- Ventilated/Trough

- 18" Rung Spacing

- Solid Corrugated Bottom

- Ventilated Corrugated Bottom

SC

VC

Page 5: Catalogo de Bandeja Electrica

PWINDUSTRIES.COM

LADDER (Flange In)

Hot-dip galvanized rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Mill galvanized rungs are 1-1/4" wide, spaced on 6", 9", or 12" centers.

Available with slotted rungs for cable ties.

Fittings for the tray systemson this page have 5" tangents.

FITTING SERIES

2

CLASSIFIEDAS AN EQUIPMENT

GROUNDING CONDUCTOR

PER N.E.C. 392.7

U.L. AREA AMPS

2000.70 in2

See pages 66-90 for fittingdimensions and part numbers.

UR

Straight Section Catalog Numbers:

Example: 0 9 - 1 D 8 0 - 0 0 2 4 - 1 8 - S L

Tray System NumberBottom Type Length Width

06

09

12

18

- 6"

- 9"

- 12"

- 18"

24

30

36

- 24"

- 30"

- 36"

Rung Options

SL - With Slots†

Leave Blankfor No Slots

Special suffixesare also used

here to indicatealternate rung

designs.

(See page 133)

†Rung slots are .31" wide x .75" long on 1" centers. Slotted rungs are normally located every

second or third rung, alternating with solid rungs. Trays with slotted rungs only are also available.

Metallic Cable Tray and Channel46 PW Industries, Inc.

MC

TC

ETA

LLIC

ABLE

RAY

AN

DH

AN

NEL

S S STEEL TRAIGHT ECTIONS

4D02

B417

1D80System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

LADDER (Flange Out)

Rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

1D81System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

VENTILATED/TROUGH

Rungs are 1-1/4" wide, spaced on 5"centers.

Available with slotted rungs for cable ties.

4D02

B453

A453System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

4D02

B462

A462System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

0010

0020

- 10'-0"

- 20'-0"

0012 - 12'-0"

*0024 - 24'-0"

*Standard

Length

This identifies the specifictray design and is used asa catalog number prefixfor straight sections,fittings, and accessories.

MATERIAL

LOAD

DEPTH NEMA CLASS

STEEL 20A,16B

RAIL

HEIGHT

4" 3"

Supplied in pairs with cadmiumplated steel hardware.

See page 94 for upgradeoptions and more information.

Necessary connectors aresupplied with all trays. Extra

connectors for field cuts or sparesmust be ordered separately.

Catalog No. (pr.)

-1302-02(System No.)

TRAY CONNECTORS

SAFE

LOAD (lbs/ft)

DEFLECTION

(inches)

SUPPORTSPAN (feet)

Safe loads and deflections are based on simple beam supports and a safety factorof 1.5 per NEMA Standard VE1.

When cable trays are supported in continuous spans, the mid-span tray deflectionis approximately 60% of the values shown.

Load data is for the tray side rails only. See page137 for safe load limitations of tray rungs and bottoms.

SAFE LOAD AND DEFLECTION DATA

10 12 14 16 18 20 22 24

0.79 1.14 1.55 2.02 2.56 3.16 3.74 4.07

216 150 110 84 67 54 44 34

3"

1

4"

3"4

3"

1

4"

3"4

3

1

4"3"8

3"41

4"

3"4

06

09

12

18

VT

- 6" Rung Spacing

- 9" Rung Spacing

- 12" Rung Spacing

- Ventilated/Trough

- 18" Rung Spacing

- Solid Corrugated Bottom

- Ventilated Corrugated Bottom

SC

VC

CORRUGATED BOTTOM

Tray bottoms are 1/2" deep corrugated sheet with 7/8" wide support ribs

on 2" centers, solid (prefix SC) or ventilated (prefix VC) construction.

31"8

Page 6: Catalogo de Bandeja Electrica

MC

TC

ETA

LLICA

BLE

RAY

AN

DH

AN

NEL

PWINDUSTRIES.COM

LADDER (Flange In)

Hot-dip galvanized rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Mill galvanized rungs are 1-1/4" wide, spaced on 6", 9", or 12" centers.

Available with slotted rungs for cable ties.

Fittings for the tray systemson this page have 5" tangents.

FITTING SERIES

2

CLASSIFIEDAS AN EQUIPMENT

GROUNDING CONDUCTOR

PER N.E.C. 392.7

U.L. AREA AMPS

4001.00 in2

See pages 66-90 for fittingdimensions and part numbers.

UR

Straight Section Catalog Numbers:

Example: 0 9 - 1 D 8 3 - 0 0 2 4 - 1 8 - S L

Tray System NumberBottom Type Length Width

06

09

12

18

- 6"

- 9"

- 12"

- 18"

24

30

36

- 24"

- 30"

- 36"

Rung Options

SL - With Slots†

Leave Blankfor No Slots

Special suffixesare also used

here to indicatealternate rung

designs.

(See page 133)

†Rung slots are .31" wide x .75" long on 1" centers. Slotted rungs are normally located every

second or third rung, alternating with solid rungs. Trays with slotted rungs only are also available.

Metallic Cable Tray and Channel 47PW Industries, Inc.

MC

TC

ETA

LLICA

BLE

RAY

AN

DH

AN

NEL

S S STEEL TRAIGHT ECTIONS

4D02

B418

1D82System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

LADDER (Flange Out)

Rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

1D83System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

VENTILATED/TROUGH

Rungs are 1-1/4" wide, spaced on 5"centers.

Available with slotted rungs for cable ties.

4D02

B454

A454System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

4D02

B463

A463System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

0010

0020

- 10'-0"

- 20'-0"

0012 - 12'-0"

*0024 - 24'-0"

*Standard

Length

This identifies the specifictray design and is used asa catalog number prefixfor straight sections,fittings, and accessories.

MATERIAL

LOAD

DEPTH NEMA CLASS

STEEL 20B,16C

RAIL

HEIGHT

4" 3"

Supplied in pairs with cadmiumplated steel hardware.

See page 94 for upgradeoptions and more information.

Necessary connectors aresupplied with all trays. Extra

connectors for field cuts or sparesmust be ordered separately.

Catalog No. (pr.)

-1302-02(System No.)

TRAY CONNECTORS

SAFE

LOAD (lbs/ft)

DEFLECTION

(inches)

SUPPORTSPAN (feet)

Safe loads and deflections are based on simple beam supports and a safety factorof 1.5 per NEMA Standard VE1.

When cable trays are supported in continuous spans, the mid-span tray deflectionis approximately 60% of the values shown.

Load data is for the tray side rails only. See page137 for safe load limitations of tray rungs and bottoms.

SAFE LOAD AND DEFLECTION DATA

10 12 14 16 18 20 22 24

0.88 1.26 1.72 2.25 2.84 3.51 4.18 4.59

312 217 159 122 96 78 63 49

3"

1

4"

3"4

3"

1

4"

3"4

3

1

4"3"8

3"41

4"

3"4

06

09

12

18

VT

- 6" Rung Spacing

- 9" Rung Spacing

- 12" Rung Spacing

- Ventilated/Trough

- 18" Rung Spacing

- Solid Corrugated Bottom

- Ventilated Corrugated Bottom

SC

VC

CORRUGATED BOTTOM

Tray bottoms are 1/2" deep corrugated sheet with 7/8" wide support ribs

on 2" centers, solid (prefix SC) or ventilated (prefix VC) construction.

31"8

Page 7: Catalogo de Bandeja Electrica

Metallic Cable Tray and Channel48 PW Industries, Inc.

MC

TC

ETA

LLIC

ABLE

RAY

AN

DH

AN

NEL

S S STEEL TRAIGHT ECTIONS

PWINDUSTRIES.COM

MATERIAL

LOAD

DEPTH

NEMA

CLASS

STEEL 20C

RAIL

HEIGHT

4" 3"

LADDER (Flange In)

Hot-dip galvanized rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Mill galvanized rungs are 1-1/4" wide, spaced on 6", 9", or 12" centers.

Available with slotted rungs for cable ties.

Fittings for the tray systemson this page have 5" tangents.

FITTING SERIES

2

CLASSIFIEDAS AN EQUIPMENT

GROUNDING CONDUCTOR

PER N.E.C. 392.7

U.L. AREA AMPS

4001.00 in2

See pages 66-90 for fittingdimensions and part numbers.

UR

Straight Section Catalog Numbers:

Example: 0 9 - 1 D 7 0 - 0 0 2 4 - 3 6 - S L

Tray System NumberBottom Type Length Width

06

09

12

18

- 6"

- 9"

- 12"

- 18"

24

30

36

- 24"

- 30"

- 36"

Rung Options

SL - With Slots†

Leave Blankfor No Slots

Special suffixesare also used

here to indicatealternate rung

designs.

(See page 133)

†Rung slots are .31" wide x .75" long on 1" centers. Slotted rungs are normally located every

second or third rung, alternating with solid rungs. Trays with slotted rungs only are also available.

4D02

B419

1D69System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

LADDER (Flange Out)

Rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

1D70System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

VENTILATED/TROUGH

Rungs are 1-1/4" wide, spaced on 5"centers.

Available with slotted rungs for cable ties.

4D02

B455

A455System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

4D02

B464

A464System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

0010

0020

- 10'-0"

- 20'-0"

0012 - 12'-0"

*0024 - 24'-0"

*Standard

Length

This identifies the specifictray design and is used asa catalog number prefixfor straight sections,fittings, and accessories.

Supplied in pairs with cadmiumplated steel hardware.

See page 94 for upgradeoptions and more information.

Necessary connectors aresupplied with all trays. Extra

connectors for field cuts or sparesmust be ordered separately.

Catalog No. (pr.)

-1302-02(System No.)

TRAY CONNECTORS

SAFE

LOAD (lbs/ft)

DEFLECTION

(inches)

SUPPORTSPAN (feet)

Safe loads and deflections are based on simple beam supports and a safety factorof 1.5 per NEMA Standard VE1.

When cable trays are supported in continuous spans, the mid-span tray deflectionis approximately 60% of the values shown.

Load data is for the tray side rails only. See page137 for safe load limitations of tray rungs and bottoms.

SAFE LOAD AND DEFLECTION DATA

10 12 14 16 18 20 22 24

0.87 1.25 1.70 2.21 2.80 3.46 4.09 4.55

400 278 204 156 123 100 81 63

3"

1

4"

3"4

3"

1

4"

3"4

3

1

4"3"8

3"41

4"

3"4

06

09

12

18

VT

- 6" Rung Spacing

- 9" Rung Spacing

- 12" Rung Spacing

- Ventilated/Trough

- 18" Rung Spacing

- Solid Corrugated Bottom

- Ventilated Corrugated Bottom

SC

VC

CORRUGATED BOTTOM

Tray bottoms are 1/2" deep corrugated sheet with 7/8" wide support ribs

on 2" centers, solid (prefix SC) or ventilated (prefix VC) construction.

31"8

Page 8: Catalogo de Bandeja Electrica

Metallic Cable Tray and Channel 49PW Industries, Inc.

MC

TC

ETA

LLICA

BLE

RAY

AN

DH

AN

NEL

S S STEEL TRAIGHT ECTIONS

PWINDUSTRIES.COM

MATERIAL

LOAD

DEPTH

NEMA

CLASS

STEEL 12B

RAIL

HEIGHT

5" 4"

LADDER (Flange In)

Rungs are 1-1/4" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

Fittings for the tray systemson this page have 2" tangents.

FITTING SERIES

1

CLASSIFIEDAS AN EQUIPMENT

GROUNDING CONDUCTOR

PER N.E.C. 392.7

U.L. AREA AMPS

1000.40 in2

See pages 66-90 for fittingdimensions and part numbers.

UR

Straight Section Catalog Numbers:

Example: 0 9 - 1 E 7 1 - 0 0 1 2 - 2 4 - S L

Tray System NumberBottom Type Length Width

06

09

12

18

- 6"

- 9"

- 12"

- 18"

24

30

36

- 24"

- 30"

- 36"

Rung Options

SL - With Slots†

Leave Blankfor No Slots

Special suffixesare also used

here to indicatealternate rung

designs.

(See page 133)

†Rung slots are .31" wide x .75" long on 1" centers. Slotted rungs are normally located every

second or third rung, alternating with solid rungs. Trays with slotted rungs only are also available.

4D02

2E71

1E71System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

LADDER (Flange Out)

Rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

1E01System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

4"

1"

5"

VENTILATED/TROUGH

Rungs are 1-1/4" wide, spaced on 5"centers.

Available with slotted rungs for cable ties.

4D02

B551

A551System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

4D02

B560

A560System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

4

1"

5"3"8

Supplied in pairs with cadmiumplated steel hardware.

See page 94 for upgradeoptions and more information.

Necessary connectors aresupplied with all trays. Extra

connectors for field cuts or sparesmust be ordered separately.

Catalog No. (pr.)

-1302-02(System No.)

TRAY CONNECTORS

0010

0020

- 10'-0"

- 20'-0"

*0012 - 12'-0"

0024 - 24'-0"

*Standard

Length

This identifies the specifictray design and is used asa catalog number prefixfor straight sections,fittings, and accessories.

4

1"

5"1"8

SAFE

LOAD (lbs/ft)

DEFLECTION

(inches)

SUPPORTSPAN (feet)

Safe loads and deflections are based on simple beam supports and a safety factorof 1.5 per NEMA Standard VE1.

When cable trays are supported in continuous spans, the mid-span tray deflectionis approximately 60% of the values shown.

Load data is for the tray side rails only. See page137 for safe load limitations of tray rungs and bottoms.

SAFE LOAD AND DEFLECTION DATA

6 8 10 12

0.19 0.33 0.52 0.75

300 169 108 75

4

1"

5"1"8

06

09

12

18

VT

- 6" Rung Spacing

- 9" Rung Spacing

- 12" Rung Spacing

- Ventilated/Trough

- 18" Rung Spacing

- Solid Corrugated Bottom

- Ventilated Corrugated Bottom

SC

VC

CORRUGATED BOTTOM

Tray bottoms are 1/2" deep corrugated sheet with 7/8" wide support ribs

on 2" centers, solid (prefix SC) or ventilated (prefix VC) construction.

Page 9: Catalogo de Bandeja Electrica

Metallic Cable Tray and Channel50 PW Industries, Inc.

MC

TC

ETA

LLIC

ABLE

RAY

AN

DH

AN

NEL

S S STEEL TRAIGHT ECTIONS

PWINDUSTRIES.COM

LADDER (Flange In)

Rungs are 1-1/4" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

Fittings for the tray systemson this page have 2" tangents.

FITTING SERIES

1

CLASSIFIEDAS AN EQUIPMENT

GROUNDING CONDUCTOR

PER N.E.C. 392.7

U.L. AREA AMPS

1000.40 in2

See pages 66-90 for fittingdimensions and part numbers.

UR

Straight Section Catalog Numbers:

Example: 0 9 - 1 E 7 2 - 0 0 1 2 - 2 4 - S L

Tray System NumberBottom Type Length Width

06

09

12

18

- 6"

- 9"

- 12"

- 18"

24

30

36

- 24"

- 30"

- 36"

Rung Options

SL - With Slots†

Leave Blankfor No Slots

Special suffixesare also used

here to indicatealternate rung

designs.

(See page 133)

†Rung slots are .31" wide x .75" long on 1" centers. Slotted rungs are normally located every

second or third rung, alternating with solid rungs. Trays with slotted rungs only are also available.

4D02

2E72

1E72System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

LADDER (Flange Out)

Rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

1E49System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

4"

1"

5"

VENTILATED/TROUGH

Rungs are 1-1/4" wide, spaced on 5"centers.

Available with slotted rungs for cable ties.

4D02

B552

A552System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

4D02

B561

A561System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

4

1"

5"3"8

Supplied in pairs with cadmiumplated steel hardware.

See page 94 for upgradeoptions and more information.

Necessary connectors aresupplied with all trays. Extra

connectors for field cuts or sparesmust be ordered separately.

Catalog No. (pr.)

-1302-02(System No.)

TRAY CONNECTORS

0010

0020

- 10'-0"

- 20'-0"

*0012 - 12'-0"

0024 - 24'-0"

*Standard

Length

This identifies the specifictray design and is used asa catalog number prefixfor straight sections,fittings, and accessories.

4

1"

5"1"8

4

1"

5"1"8

MATERIAL

LOAD

DEPTH NEMA CLASS

STEEL 12C,16A

RAIL

HEIGHT

5" 4"

SAFE

LOAD (lbs/ft)

DEFLECTION

(inches)

SUPPORTSPAN (feet)

Safe loads and deflections are based on simple beam supports and a safety factorof 1.5 per NEMA Standard VE1.

When cable trays are supported in continuous spans, the mid-span tray deflectionis approximately 60% of the values shown.

Load data is for the tray side rails only. See page137 for safe load limitations of tray rungs and bottoms.

SAFE LOAD AND DEFLECTION DATA

1086 12 14 16

0.21 0.38 0.59 0.85 1.13 1.40

400 225 144 100 71 52

06

09

12

18

VT

- 6" Rung Spacing

- 9" Rung Spacing

- 12" Rung Spacing

- Ventilated/Trough

- 18" Rung Spacing

- Solid Corrugated Bottom

- Ventilated Corrugated Bottom

SC

VC

CORRUGATED BOTTOM

Tray bottoms are 1/2" deep corrugated sheet with 7/8" wide support ribs

on 2" centers, solid (prefix SC) or ventilated (prefix VC) construction.

Page 10: Catalogo de Bandeja Electrica

Metallic Cable Tray and Channel 51PW Industries, Inc.

MC

TC

ETA

LLICA

BLE

RAY

AN

DH

AN

NEL

S S STEEL TRAIGHT ECTIONS

PWINDUSTRIES.COM

LADDER (Flange In)

Hot-dip galvanized rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Mill galvanized rungs are 1-1/4" wide, spaced on 6", 9", or 12" centers.

Available with slotted rungs for cable ties.

Fittings for the tray systemson this page have 5" tangents.

FITTING SERIES

2

CLASSIFIEDAS AN EQUIPMENT

GROUNDING CONDUCTOR

PER N.E.C. 392.7

U.L. AREA AMPS

4001.00 in2

See pages 66-90 for fittingdimensions and part numbers.

UR

Straight Section Catalog Numbers:

Example: 0 9 - 1 E 4 6 - 0 0 2 4 - 1 2 - S L

Tray System NumberBottom Type Length Width

06

09

12

18

- 6"

- 9"

- 12"

- 18"

24

30

36

- 24"

- 30"

- 36"

Rung Options

SL - With Slots†

Leave Blankfor No Slots

Special suffixesare also used

here to indicatealternate rung

designs.

(See page 133)

†Rung slots are .31" wide x .75" long on 1" centers. Slotted rungs are normally located every

second or third rung, alternating with solid rungs. Trays with slotted rungs only are also available.

4D02

B518

1E45System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

LADDER (Flange Out)

Rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

1E46System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

VENTILATED/TROUGH

Rungs are 1-1/4" wide, spaced on 5"centers.

Available with slotted rungs for cable ties.

4D02

B554

A554System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

4D02

B562

A562System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

0010

0020

- 10'-0"

- 20'-0"

0012 - 12'-0"

*0024 - 24'-0"

*Standard

Length

This identifies the specifictray design and is used asa catalog number prefixfor straight sections,fittings, and accessories.

MATERIAL

LOAD

DEPTH NEMA CLASS

STEEL 20B,16C

RAIL

HEIGHT

5" 4"

4"

1

5"

3"4

4"

1

5"

3"4

4

1

5"3"8

3"4

Supplied in pairs with cadmiumplated steel hardware.

See page 94 for upgradeoptions and more information.

Necessary connectors aresupplied with all trays. Extra

connectors for field cuts or sparesmust be ordered separately.

Catalog No. (pr.)

-1302-02(System No.)

TRAY CONNECTORS

SAFE

LOAD (lbs/ft)

DEFLECTION

(inches)

SUPPORTSPAN (feet)

Safe loads and deflections are based on simple beam supports and a safety factorof 1.5 per NEMA Standard VE1.

When cable trays are supported in continuous spans, the mid-span tray deflectionis approximately 60% of the values shown.

Load data is for the tray side rails only. See page137 for safe load limitations of tray rungs and bottoms.

SAFE LOAD AND DEFLECTION DATA

10 12 14 16 18 20 22 24

1

5"

3"4

0.62 0.90 1.22 1.59 2.02 2.49 2.92 3.25

304 211 155 119 94 76 61 48

06

09

12

18

VT

- 6" Rung Spacing

- 9" Rung Spacing

- 12" Rung Spacing

- Ventilated/Trough

- 18" Rung Spacing

- Solid Corrugated Bottom

- Ventilated Corrugated Bottom

SC

VC

CORRUGATED BOTTOM

Tray bottoms are 1/2" deep corrugated sheet with 7/8" wide support ribs

on 2" centers, solid (prefix SC) or ventilated (prefix VC) construction.

41"8

Page 11: Catalogo de Bandeja Electrica

Metallic Cable Tray and Channel52 PW Industries, Inc.

MC

TC

ETA

LLIC

ABLE

RAY

AN

DH

AN

NEL

S S STEEL TRAIGHT ECTIONS

PWINDUSTRIES.COM

MATERIAL

LOAD

DEPTH

NEMA

CLASS

STEEL 20C

RAIL

HEIGHT

5" 4"

LADDER (Flange In)

Hot-dip galvanized rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Mill galvanized rungs are 1-1/4" wide, spaced on 6", 9", or 12" centers.

Available with slotted rungs for cable ties.

Fittings for the tray systemson this page have 5" tangents.

FITTING SERIES

2

CLASSIFIEDAS AN EQUIPMENT

GROUNDING CONDUCTOR

PER N.E.C. 392.7

U.L. AREA AMPS

4001.00 in2

See pages 66-90 for fittingdimensions and part numbers.

UR

Straight Section Catalog Numbers:

Example: 0 9 - 1 E 5 4 - 0 0 2 4 - 1 8 - S L

Tray System NumberBottom Type Length Width

06

09

12

18

- 6"

- 9"

- 12"

- 18"

24

30

36

- 24"

- 30"

- 36"

Rung Options

SL - With Slots†

Leave Blankfor No Slots

Special suffixesare also used

here to indicatealternate rung

designs.

(See page 133)

†Rung slots are .31" wide x .75" long on 1" centers. Slotted rungs are normally located every

second or third rung, alternating with solid rungs. Trays with slotted rungs only are also available.

4D02

B519

1E53System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

LADDER (Flange Out)

Rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

1E54System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

VENTILATED/TROUGH

Rungs are 1-1/4" wide, spaced on 5"centers.

Available with slotted rungs for cable ties.

4D02

B555

A555System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

4D02

B563

A563System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

0010

0020

- 10'-0"

- 20'-0"

0012 - 12'-0"

*0024 - 24'-0"

*Standard

Length

This identifies the specifictray design and is used asa catalog number prefixfor straight sections,fittings, and accessories.

Supplied in pairs with cadmiumplated steel hardware.

See page 94 for upgradeoptions and more information.

Necessary connectors aresupplied with all trays. Extra

connectors for field cuts or sparesmust be ordered separately.

Catalog No. (pr.)

-1302-02(System No.)

TRAY CONNECTORS

SAFE

LOAD (lbs/ft)

DEFLECTION

(inches)

SUPPORTSPAN (feet)

Safe loads and deflections are based on simple beam supports and a safety factorof 1.5 per NEMA Standard VE1.

When cable trays are supported in continuous spans, the mid-span tray deflectionis approximately 60% of the values shown.

Load data is for the tray side rails only. See page137 for safe load limitations of tray rungs and bottoms.

SAFE LOAD AND DEFLECTION DATA

10 12 14 16 18 20 22 24

0.75 1.08 1.47 1.92 2.43 3.00 3.54 3.94

400 278 204 156 123 100 81 63

4"

1

5"

3"4

4"

1

5"

3"4

4

1

5"3"8

3"41

5"

3"4

06

09

12

18

VT

- 6" Rung Spacing

- 9" Rung Spacing

- 12" Rung Spacing

- Ventilated/Trough

- 18" Rung Spacing

- Solid Corrugated Bottom

- Ventilated Corrugated Bottom

SC

VC

CORRUGATED BOTTOM

Tray bottoms are 1/2" deep corrugated sheet with 7/8" wide support ribs

on 2" centers, solid (prefix SC) or ventilated (prefix VC) construction.

41"8

Page 12: Catalogo de Bandeja Electrica

Metallic Cable Tray and Channel 53PW Industries, Inc.

MC

TC

ETA

LLICA

BLE

RAY

AN

DH

AN

NEL

S S STEEL TRAIGHT ECTIONS

PWINDUSTRIES.COM

MATERIAL

LOAD

DEPTH

NEMA

CLASS

STEEL 12B

RAIL

HEIGHT

6" 5"

LADDER (Flange In)

Rungs are 1-1/4" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

Fittings for the tray systemson this page have 2" tangents.

FITTING SERIES

1

CLASSIFIEDAS AN EQUIPMENT

GROUNDING CONDUCTOR

PER N.E.C. 392.7

U.L. AREA AMPS

1000.40 in2

See pages 66-90 for fittingdimensions and part numbers.

UR

Straight Section Catalog Numbers:

Example: 0 9 - A 6 3 8 - 0 0 1 2 - 2 4 - S L

Tray System NumberBottom Type Length Width

06

09

12

18

- 6"

- 9"

- 12"

- 18"

24

30

36

- 24"

- 30"

- 36"

Rung Options

SL - With Slots†

Leave Blankfor No Slots

Special suffixesare also used

here to indicatealternate rung

designs.

(See page 133)

†Rung slots are .31" wide x .75" long on 1" centers. Slotted rungs are normally located every

second or third rung, alternating with solid rungs. Trays with slotted rungs only are also available.

4D02

B638

A638System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

LADDER (Flange Out)

Rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

1F56System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

5"

1"

6"

VENTILATED/TROUGH

Rungs are 1-1/4" wide, spaced on 5"centers.

Available with slotted rungs for cable ties.

4D02

B651

A651System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

4D02

B660

A660System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

5

1"

6"3"8

Supplied in pairs with cadmiumplated steel hardware.

See page 94 for upgradeoptions and more information.

Necessary connectors aresupplied with all trays. Extra

connectors for field cuts or sparesmust be ordered separately.

Catalog No. (pr.)

-1302-02(System No.)

TRAY CONNECTORS

0010

0020

- 10'-0"

- 20'-0"

*0012 - 12'-0"

0024 - 24'-0"

*Standard

Length

This identifies the specifictray design and is used asa catalog number prefixfor straight sections,fittings, and accessories.

5

1"

6"1"8

SAFE

LOAD (lbs/ft)

DEFLECTION

(inches)

SUPPORTSPAN (feet)

Safe loads and deflections are based on simple beam supports and a safety factorof 1.5 per NEMA Standard VE1.

When cable trays are supported in continuous spans, the mid-span tray deflectionis approximately 60% of the values shown.

Load data is for the tray side rails only. See page137 for safe load limitations of tray rungs and bottoms.

SAFE LOAD AND DEFLECTION DATA

6 8 10 12

0.11 0.19 0.29 0.42

316 178 114 79

5

1"

6"1"8

06

09

12

18

VT

- 6" Rung Spacing

- 9" Rung Spacing

- 12" Rung Spacing

- Ventilated/Trough

- 18" Rung Spacing

- Solid Corrugated Bottom

- Ventilated Corrugated Bottom

SC

VC

CORRUGATED BOTTOM

Tray bottoms are 1/2" deep corrugated sheet with 7/8" wide support ribs

on 2" centers, solid (prefix SC) or ventilated (prefix VC) construction.

Page 13: Catalogo de Bandeja Electrica

Metallic Cable Tray and Channel54 PW Industries, Inc.

MC

TC

ETA

LLIC

ABLE

RAY

AN

DH

AN

NEL

S S STEEL TRAIGHT ECTIONS

PWINDUSTRIES.COM

LADDER (Flange In)

Rungs are 1-1/4" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

Fittings for the tray systemson this page have 2" tangents.

FITTING SERIES

1

CLASSIFIEDAS AN EQUIPMENT

GROUNDING CONDUCTOR

PER N.E.C. 392.7

U.L. AREA AMPS

1000.40 in2

See pages 66-90 for fittingdimensions and part numbers.

UR

Straight Section Catalog Numbers:

Example: 0 9 - 1 F 6 9 - 0 0 1 2 - 1 8 - S L

Tray System NumberBottom Type Length Width

06

09

12

18

- 6"

- 9"

- 12"

- 18"

24

30

36

- 24"

- 30"

- 36"

Rung Options

SL - With Slots†

Leave Blankfor No Slots

Special suffixesare also used

here to indicatealternate rung

designs.

(See page 133)

†Rung slots are .31" wide x .75" long on 1" centers. Slotted rungs are normally located every

second or third rung, alternating with solid rungs. Trays with slotted rungs only are also available.

4D02

B639

A639System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

LADDER (Flange Out)

Rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

1F69System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

VENTILATED/TROUGH

Rungs are 1-1/4" wide, spaced on 5"centers.

Available with slotted rungs for cable ties.

4D02

B652

A652System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

4D02

B661

A661System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

Supplied in pairs with cadmiumplated steel hardware.

See page 94 for upgradeoptions and more information.

Necessary connectors aresupplied with all trays. Extra

connectors for field cuts or sparesmust be ordered separately.

Catalog No. (pr.)

-1302-02(System No.)

TRAY CONNECTORS

0010

0020

- 10'-0"

- 20'-0"

*0012 - 12'-0"

0024 - 24'-0"

*Standard

Length

This identifies the specifictray design and is used asa catalog number prefixfor straight sections,fittings, and accessories.

MATERIAL

LOAD

DEPTH NEMA CLASS

STEEL 12C,16A

RAIL

HEIGHT

6" 5"

SAFE

LOAD (lbs/ft)

DEFLECTION

(inches)

SUPPORTSPAN (feet)

Safe loads and deflections are based on simple beam supports and a safety factorof 1.5 per NEMA Standard VE1.

When cable trays are supported in continuous spans, the mid-span tray deflectionis approximately 60% of the values shown.

Load data is for the tray side rails only. See page137 for safe load limitations of tray rungs and bottoms.

SAFE LOAD AND DEFLECTION DATA

1086 12 14 16

5"

1"

6"

5

1"

6"3"8

5

1"

6"1"8

5

1"

6"1"8

0.13 0.22 0.35 0.50 0.65 0.83

420 236 151 105 74 55

06

09

12

18

VT

- 6" Rung Spacing

- 9" Rung Spacing

- 12" Rung Spacing

- Ventilated/Trough

- 18" Rung Spacing

- Solid Corrugated Bottom

- Ventilated Corrugated Bottom

SC

VC

CORRUGATED BOTTOM

Tray bottoms are 1/2" deep corrugated sheet with 7/8" wide support ribs

on 2" centers, solid (prefix SC) or ventilated (prefix VC) construction.

Page 14: Catalogo de Bandeja Electrica

Metallic Cable Tray and Channel 55PW Industries, Inc.

MC

TC

ETA

LLICA

BLE

RAY

AN

DH

AN

NEL

S S STEEL TRAIGHT ECTIONS

PWINDUSTRIES.COM

LADDER (Flange In)

Hot-dip galvanized rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Mill galvanized rungs are 1-1/4" wide, spaced on 6", 9", or 12" centers.

Available with slotted rungs for cable ties.

Fittings for the tray systemson this page have 5" tangents.

FITTING SERIES

2

CLASSIFIEDAS AN EQUIPMENT

GROUNDING CONDUCTOR

PER N.E.C. 392.7

U.L. AREA AMPS

4001.00 in2

See pages 66-90 for fittingdimensions and part numbers.

UR

Straight Section Catalog Numbers:

Example: 0 9 - 1 F 4 6 - 0 0 2 4 - 3 6 - S L

Tray System NumberBottom Type Length Width

06

09

12

18

- 6"

- 9"

- 12"

- 18"

24

30

36

- 24"

- 30"

- 36"

Rung Options

SL - With Slots†

Leave Blankfor No Slots

Special suffixesare also used

here to indicatealternate rung

designs.

(See page 133)

†Rung slots are .31" wide x .75" long on 1" centers. Slotted rungs are normally located every

second or third rung, alternating with solid rungs. Trays with slotted rungs only are also available.

4D02

B618

1F45System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

LADDER (Flange Out)

Rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

1F46System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

VENTILATED/TROUGH

Rungs are 1-1/4" wide, spaced on 5"centers.

Available with slotted rungs for cable ties.

4D02

B654

A654System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

4D02

B662

A662System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

0010

0020

- 10'-0"

- 20'-0"

0012 - 12'-0"

*0024 - 24'-0"

*Standard

Length

This identifies the specifictray design and is used asa catalog number prefixfor straight sections,fittings, and accessories.

MATERIAL

LOAD

DEPTH NEMA CLASS

STEEL 20B,16C

RAIL

HEIGHT

6" 5"

5"

1

6"

3"4

5"

1

6"

3"4

5

1

6"3"8

3"4

Supplied in pairs with cadmiumplated steel hardware.

See page 94 for upgradeoptions and more information.

Necessary connectors aresupplied with all trays. Extra

connectors for field cuts or sparesmust be ordered separately.

Catalog No. (pr.)

-1302-02(System No.)

TRAY CONNECTORS

SAFE

LOAD (lbs/ft)

DEFLECTION

(inches)

SUPPORTSPAN (feet)

Safe loads and deflections are based on simple beam supports and a safety factorof 1.5 per NEMA Standard VE1.

When cable trays are supported in continuous spans, the mid-span tray deflectionis approximately 60% of the values shown.

Load data is for the tray side rails only. See page137 for safe load limitations of tray rungs and bottoms.

SAFE LOAD AND DEFLECTION DATA

10 12 14 16 18 20 22 24

1

6"

3"4

0.47 0.68 0.92 1.20 1.52 1.88 2.24 2.47

336 233 171 131 104 84 68 53

06

09

12

18

VT

- 6" Rung Spacing

- 9" Rung Spacing

- 12" Rung Spacing

- Ventilated/Trough

- 18" Rung Spacing

- Solid Corrugated Bottom

- Ventilated Corrugated Bottom

SC

VC

CORRUGATED BOTTOM

Tray bottoms are 1/2" deep corrugated sheet with 7/8" wide support ribs

on 2" centers, solid (prefix SC) or ventilated (prefix VC) construction.

51"8

Page 15: Catalogo de Bandeja Electrica

Metallic Cable Tray and Channel56 PW Industries, Inc.

MC

TC

ETA

LLIC

ABLE

RAY

AN

DH

AN

NEL

S S STEEL TRAIGHT ECTIONS

PWINDUSTRIES.COM

LADDER (Flange In)

Hot-dip galvanized rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Mill galvanized rungs are 1-1/4" wide, spaced on 6", 9", or 12" centers.

Available with slotted rungs for cable ties.

Fittings for the tray systemson this page have 5" tangents.

FITTING SERIES

2

CLASSIFIEDAS AN EQUIPMENT

GROUNDING CONDUCTOR

PER N.E.C. 392.7

U.L. AREA AMPS

4001.00 in2

See pages 66-90 for fittingdimensions and part numbers.

UR

Straight Section Catalog Numbers:

Example: 0 9 - 1 F 5 4 - 0 0 2 4 - 3 6 - S L

Tray System NumberBottom Type Length Width

06

09

12

18

- 6"

- 9"

- 12"

- 18"

24

30

36

- 24"

- 30"

- 36"

Rung Options

SL - With Slots†

Leave Blankfor No Slots

Special suffixesare also used

here to indicatealternate rung

designs.

(See page 133)

†Rung slots are .31" wide x .75" long on 1" centers. Slotted rungs are normally located every

second or third rung, alternating with solid rungs. Trays with slotted rungs only are also available.

4D02

B619

1F53System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

LADDER (Flange Out)

Rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

1F54System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

VENTILATED/TROUGH

Rungs are 1-1/4" wide, spaced on 5"centers.

Available with slotted rungs for cable ties.

4D02

B655

A655System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

4D02

B663

A663System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

0010

0020

- 10'-0"

- 20'-0"

0012 - 12'-0"

*0024 - 24'-0"

*Standard

Length

This identifies the specifictray design and is used asa catalog number prefixfor straight sections,fittings, and accessories.

Supplied in pairs with cadmiumplated steel hardware.

See page 94 for upgradeoptions and more information.

Necessary connectors aresupplied with all trays. Extra

connectors for field cuts or sparesmust be ordered separately.

Catalog No. (pr.)

-1302-02(System No.)

TRAY CONNECTORS

SAFE

LOAD (lbs/ft)

DEFLECTION

(inches)

SUPPORTSPAN (feet)

Safe loads and deflections are based on simple beam supports and a safety factorof 1.5 per NEMA Standard VE1.

When cable trays are supported in continuous spans, the mid-span tray deflectionis approximately 60% of the values shown.

Load data is for the tray side rails only. See page137 for safe load limitations of tray rungs and bottoms.

SAFE LOAD AND DEFLECTION DATA

10 12 14 16 18 20 22 24

MATERIAL

LOAD

DEPTH

NEMA

CLASS

STEEL 20C

RAIL

HEIGHT

6" 5"

5"

1

6"

3"4

5"

1

6"

3"4

5

1

6"3"8

3"41

6"

3"4

0.52 0.75 1.02 1.34 1.69 2.09 2.48 2.75

460 319 235 180 142 115 93 73

06

09

12

18

VT

- 6" Rung Spacing

- 9" Rung Spacing

- 12" Rung Spacing

- Ventilated/Trough

- 18" Rung Spacing

- Solid Corrugated Bottom

- Ventilated Corrugated Bottom

SC

VC

CORRUGATED BOTTOM

Tray bottoms are 1/2" deep corrugated sheet with 7/8" wide support ribs

on 2" centers, solid (prefix SC) or ventilated (prefix VC) construction.

51"8

Page 16: Catalogo de Bandeja Electrica

Metallic Cable Tray and Channel 57PW Industries, Inc.

MC

TC

ETA

LLICA

BLE

RAY

AN

DH

AN

NEL

S S STEEL TRAIGHT ECTIONS

PWINDUSTRIES.COM

LADDER (Flange In)

Rungs are 1-1/4" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

Fittings for the tray systemson this page have 2" tangents.

FITTING SERIES

1

CLASSIFIEDAS AN EQUIPMENT

GROUNDING CONDUCTOR

PER N.E.C. 392.7

U.L. AREA AMPS

1000.40 in2

See pages 66-90 for fittingdimensions and part numbers.

UR

Straight Section Catalog Numbers:

Example: 0 9 - 1 7 7 1 - 0 0 1 2 - 2 4 - S L

Tray System NumberBottom Type Length Width

06

09

12

18

- 6"

- 9"

- 12"

- 18"

24

30

36

- 24"

- 30"

- 36"

Rung Options

SL - With Slots†

Leave Blankfor No Slots

Special suffixesare also used

here to indicatealternate rung

designs.

(See page 133)

†Rung slots are .31" wide x .75" long on 1" centers. Slotted rungs are normally located every

second or third rung, alternating with solid rungs. Trays with slotted rungs only are also available.

4D02

2771

1771System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

LADDER (Flange Out)

Rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

1780System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

6"

1"

7"

VENTILATED/TROUGH

Rungs are 1-1/4" wide, spaced on 5"centers.

Available with slotted rungs for cable ties.

4D02

B751

A751System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

4D02

B760

A760System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

6

1"

7"3"8

Supplied in pairs with cadmiumplated steel hardware.

See page 94 for upgradeoptions and more information.

Necessary connectors aresupplied with all trays. Extra

connectors for field cuts or sparesmust be ordered separately.

Catalog No. (pr.)

-1302-02(System No.)

TRAY CONNECTORS

0010

0020

- 10'-0"

- 20'-0"

*0012 - 12'-0"

0024 - 24'-0"

*Standard

Length

This identifies the specifictray design and is used asa catalog number prefixfor straight sections,fittings, and accessories.

6

1"

7"1"8

SAFE

LOAD (lbs/ft)

DEFLECTION

(inches)

SUPPORTSPAN (feet)

Safe loads and deflections are based on simple beam supports and a safety factorof 1.5 per NEMA Standard VE1.

When cable trays are supported in continuous spans, the mid-span tray deflectionis approximately 60% of the values shown.

Load data is for the tray side rails only. See page137 for safe load limitations of tray rungs and bottoms.

SAFE LOAD AND DEFLECTION DATA

6 8 10 12

MATERIAL

LOAD

DEPTH

NEMA

CLASS

STEEL 12B

RAIL

HEIGHT

7" 6"

6

1"

7"1"8

0.10 0.16 0.24 0.35

300 169 108 75

06

09

12

18

VT

- 6" Rung Spacing

- 9" Rung Spacing

- 12" Rung Spacing

- Ventilated/Trough

- 18" Rung Spacing

- Solid Corrugated Bottom

- Ventilated Corrugated Bottom

SC

VC

CORRUGATED BOTTOM

Tray bottoms are 1/2" deep corrugated sheet with 7/8" wide support ribs

on 2" centers, solid (prefix SC) or ventilated (prefix VC) construction.

Page 17: Catalogo de Bandeja Electrica

Metallic Cable Tray and Channel58 PW Industries, Inc.

MC

TC

ETA

LLIC

ABLE

RAY

AN

DH

AN

NEL

S S STEEL TRAIGHT ECTIONS

PWINDUSTRIES.COM

LADDER (Flange In)

Rungs are 1-1/4" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

Fittings for the tray systemson this page have 2" tangents.

FITTING SERIES

1

CLASSIFIEDAS AN EQUIPMENT

GROUNDING CONDUCTOR

PER N.E.C. 392.7

U.L. AREA AMPS

1000.40 in2

See pages 66-90 for fittingdimensions and part numbers.

UR

Straight Section Catalog Numbers:

Example: 0 9 - 1 7 7 2 - 0 0 1 2 - 2 4 - S L

Tray System NumberBottom Type Length Width

06

09

12

18

- 6"

- 9"

- 12"

- 18"

24

30

36

- 24"

- 30"

- 36"

Rung Options

SL - With Slots†

Leave Blankfor No Slots

Special suffixesare also used

here to indicatealternate rung

designs.

(See page 133)

†Rung slots are .31" wide x .75" long on 1" centers. Slotted rungs are normally located every

second or third rung, alternating with solid rungs. Trays with slotted rungs only are also available.

4D02

2772

1772System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

LADDER (Flange Out)

Rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

1779System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

VENTILATED/TROUGH

Rungs are 1-1/4" wide, spaced on 5"centers.

Available with slotted rungs for cable ties.

4D02

B752

A752System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

4D02

B761

A761System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

Supplied in pairs with cadmiumplated steel hardware.

See page 94 for upgradeoptions and more information.

Necessary connectors aresupplied with all trays. Extra

connectors for field cuts or sparesmust be ordered separately.

Catalog No. (pr.)

-1302-02(System No.)

TRAY CONNECTORS

0010

0020

- 10'-0"

- 20'-0"

*0012 - 12'-0"

0024 - 24'-0"

*Standard

Length

This identifies the specifictray design and is used asa catalog number prefixfor straight sections,fittings, and accessories.

MATERIAL

LOAD

DEPTH NEMA CLASS

STEEL 12C,16A

RAIL

HEIGHT

7" 6"

SAFE

LOAD (lbs/ft)

DEFLECTION

(inches)

SUPPORTSPAN (feet)

Safe loads and deflections are based on simple beam supports and a safety factorof 1.5 per NEMA Standard VE1.

When cable trays are supported in continuous spans, the mid-span tray deflectionis approximately 60% of the values shown.

Load data is for the tray side rails only. See page137 for safe load limitations of tray rungs and bottoms.

SAFE LOAD AND DEFLECTION DATA

1086 12 14 16

0.10 0.18 0.28 0.40 0.53 0.66

400 225 144 100 71 52

6"

1"

7"

6

1"

7"3"8

6

1"

7"1"8

6

1"

7"1"8

06

09

12

18

VT

- 6" Rung Spacing

- 9" Rung Spacing

- 12" Rung Spacing

- Ventilated/Trough

- 18" Rung Spacing

- Solid Corrugated Bottom

- Ventilated Corrugated Bottom

SC

VC

CORRUGATED BOTTOM

Tray bottoms are 1/2" deep corrugated sheet with 7/8" wide support ribs

on 2" centers, solid (prefix SC) or ventilated (prefix VC) construction.

Page 18: Catalogo de Bandeja Electrica

Metallic Cable Tray and Channel 59PW Industries, Inc.

MC

TC

ETA

LLICA

BLE

RAY

AN

DH

AN

NEL

S S STEEL TRAIGHT ECTIONS

PWINDUSTRIES.COM

LADDER (Flange In)

Hot-dip galvanized rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Mill galvanized rungs are 1-1/4" wide, spaced on 6", 9", or 12" centers.

Available with slotted rungs for cable ties.

Fittings for the tray systemson this page have 5" tangents.

FITTING SERIES

2

CLASSIFIEDAS AN EQUIPMENT

GROUNDING CONDUCTOR

PER N.E.C. 392.7

U.L. AREA AMPS

4001.00 in2

See pages 66-90 for fittingdimensions and part numbers.

UR

Straight Section Catalog Numbers:

Example: 0 9 - 1 7 5 6 - 0 0 2 4 - 3 6 - S L

Tray System NumberBottom Type Length Width

06

09

12

18

- 6"

- 9"

- 12"

- 18"

24

30

36

- 24"

- 30"

- 36"

Rung Options

SL - With Slots†

Leave Blankfor No Slots

Special suffixesare also used

here to indicatealternate rung

designs.

(See page 133)

†Rung slots are .31" wide x .75" long on 1" centers. Slotted rungs are normally located every

second or third rung, alternating with solid rungs. Trays with slotted rungs only are also available.

4D02

2773

1755System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

LADDER (Flange Out)

Rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

1756System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

VENTILATED/TROUGH

Rungs are 1-1/4" wide, spaced on 5"centers.

Available with slotted rungs for cable ties.

4D02

B754

A754System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

4D02

B762

A762System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

0010

0020

- 10'-0"

- 20'-0"

0012 - 12'-0"

*0024 - 24'-0"

*Standard

Length

This identifies the specifictray design and is used asa catalog number prefixfor straight sections,fittings, and accessories.

MATERIAL

LOAD

DEPTH NEMA CLASS

STEEL 20B,16C

RAIL

HEIGHT

7" 6"

6"

1

7"

3"4

6"

1

7"

3"4

6

1

7"3"8

3"4

Supplied in pairs with cadmiumplated steel hardware.

See page 94 for upgradeoptions and more information.

Necessary connectors aresupplied with all trays. Extra

connectors for field cuts or sparesmust be ordered separately.

Catalog No. (pr.)

-1302-02(System No.)

TRAY CONNECTORS

SAFE

LOAD (lbs/ft)

DEFLECTION

(inches)

SUPPORTSPAN (feet)

Safe loads and deflections are based on simple beam supports and a safety factorof 1.5 per NEMA Standard VE1.

When cable trays are supported in continuous spans, the mid-span tray deflectionis approximately 60% of the values shown.

Load data is for the tray side rails only. See page137 for safe load limitations of tray rungs and bottoms.

SAFE LOAD AND DEFLECTION DATA

10 12 14 16 18 20 22 24

0.38 0.54 0.73 0.96 1.22 1.50 1.79 1.99

300 208 153 117 93 75 61 48

1

7"

3"4

06

09

12

18

VT

- 6" Rung Spacing

- 9" Rung Spacing

- 12" Rung Spacing

- Ventilated/Trough

- 18" Rung Spacing

- Solid Corrugated Bottom

- Ventilated Corrugated Bottom

SC

VC

CORRUGATED BOTTOM

Tray bottoms are 1/2" deep corrugated sheet with 7/8" wide support ribs

on 2" centers, solid (prefix SC) or ventilated (prefix VC) construction.

61"8

Page 19: Catalogo de Bandeja Electrica

Metallic Cable Tray and Channel60 PW Industries, Inc.

MC

TC

ETA

LLIC

ABLE

RAY

AN

DH

AN

NEL

S S STEEL TRAIGHT ECTIONS

PWINDUSTRIES.COM

LADDER (Flange In)

Hot-dip galvanized rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Mill galvanized rungs are 1-1/4" wide, spaced on 6", 9", or 12" centers.

Available with slotted rungs for cable ties.

Fittings for the tray systemson this page have 5" tangents.

FITTING SERIES

2

CLASSIFIEDAS AN EQUIPMENT

GROUNDING CONDUCTOR

PER N.E.C. 392.7

U.L. AREA AMPS

4001.00 in2

See pages 66-90 for fittingdimensions and part numbers.

UR

Straight Section Catalog Numbers:

Example: 0 9 - 1 7 5 4 - 0 0 2 4 - 3 6 - S L

Tray System NumberBottom Type Length Width

06

09

12

18

- 6"

- 9"

- 12"

- 18"

24

30

36

- 24"

- 30"

- 36"

Rung Options

SL - With Slots†

Leave Blankfor No Slots

Special suffixesare also used

here to indicatealternate rung

designs.

(See page 133)

†Rung slots are .31" wide x .75" long on 1" centers. Slotted rungs are normally located every

second or third rung, alternating with solid rungs. Trays with slotted rungs only are also available.

4D02

2774

1753System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

LADDER (Flange Out)

Rungs are 1" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

1754System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

VENTILATED/TROUGH

Rungs are 1-1/4" wide, spaced on 5"centers.

Available with slotted rungs for cable ties.

4D02

B755

A755System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

4D02

B763

A763System Number

Hot-Dip GalvanizedAfter Fab. ASTM A123

System Number

Mill GalvanizedASTM A653

0010

0020

- 10'-0"

- 20'-0"

0012 - 12'-0"

*0024 - 24'-0"

*Standard

Length

This identifies the specifictray design and is used asa catalog number prefixfor straight sections,fittings, and accessories.

Supplied in pairs with cadmiumplated steel hardware.

See page 94 for upgradeoptions and more information.

Necessary connectors aresupplied with all trays. Extra

connectors for field cuts or sparesmust be ordered separately.

Catalog No. (pr.)

-1302-02(System No.)

TRAY CONNECTORS

SAFE

LOAD (lbs/ft)

DEFLECTION

(inches)

SUPPORTSPAN (feet)

Safe loads and deflections are based on simple beam supports and a safety factorof 1.5 per NEMA Standard VE1.

When cable trays are supported in continuous spans, the mid-span tray deflectionis approximately 60% of the values shown.

Load data is for the tray side rails only. See page137 for safe load limitations of tray rungs and bottoms.

SAFE LOAD AND DEFLECTION DATA

10 12 14 16 18 20 22 24

MATERIAL

LOAD

DEPTH

NEMA

CLASS

STEEL 20C

RAIL

HEIGHT

7" 6"

6"

1

7"

3"4

6"

1

7"

3"4

6

1

7"3"8

3"41

7"

3"4

0.44 0.63 0.86 1.12 1.42 1.75 2.16 2.42

460 319 235 180 142 115 93 73

06

09

12

18

VT

- 6" Rung Spacing

- 9" Rung Spacing

- 12" Rung Spacing

- Ventilated/Trough

- 18" Rung Spacing

- Solid Corrugated Bottom

- Ventilated Corrugated Bottom

SC

VC

CORRUGATED BOTTOM

Tray bottoms are 1/2" deep corrugated sheet with 7/8" wide support ribs

on 2" centers, solid (prefix SC) or ventilated (prefix VC) construction.

61"8

Page 20: Catalogo de Bandeja Electrica

Metallic Cable Tray and Channel 61PW Industries, Inc.

MC

TC

ETA

LLICA

BLE

RAY

AN

DH

AN

NEL

S S STEEL TRAIGHT ECTIONS

PWINDUSTRIES.COM

LADDER

Rungs are 1-5/8" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

System Number

1952

SAFE

LOAD (lbs/ft)

DEFLECTION

(inches)

SUPPORTSPAN (feet)

Safe loads and deflections are based on simple beam supports and a safety factorof 1.5 per NEMA Standard VE1.

When cable trays are supported in continuous spans, the mid-span tray deflectionis approximately 60% of the values shown.

Load data is for the tray side rails only. See page137 for safe load limitations of tray rungs and bottoms.

SAFE LOAD AND DEFLECTION DATA

16 20 24 26 30 34 36 40

Supplied in pairs with cadmiumplated steel hardware.

See page 94 for upgradeoptions and more information.

Necessary connectors aresupplied with all trays. Extra

connectors for field cuts or sparesmust be ordered separately.

Catalog No. (pr.)

-1302-02(System No.)

1972

SOLID BOTTOM

System Number

1962

VENTILATED/TROUGH

System Number

Rungs are 4" wide, spaced on 8" centers for straight sections.

Fittings have 1-5/8" wide rungs spaced on 5" centers.

Available with slotted rungs for cable ties.

Tray bottoms are flat sheet placed on top of

1-5/8" wide rungs located on 12" centers.

TRAY CONNECTORS

I-Beam Cable Trays

for Long Spans and Heavy Loads

All systems are hot-dip galvanizedafter fabrication per ASTM A123.Finish:

Made from C-Channels with1" flanges facing out. See pages 66-90.Fittings:

Made from M8x6.5 structural-steel I-Beams per ASTM A36.Side Rails:

Minimum quantities mayapply; Contact PW for current lead times.Availability:

Fittings for the tray systemson this page have 5" tangents.

FITTING SERIES

2

CLASSIFIEDAS AN EQUIPMENT

GROUNDING CONDUCTOR

PER N.E.C. 392.7

U.L. AREA AMPS

6001.50 in2

See pages 66-90 for fittingdimensions and part numbers.

UR

Straight Section Catalog Numbers:

Example: 0 9 - 1 9 5 2 - 0 0 4 0 - 3 6 - S L

Tray System Number

06

09

12

18

VT

- 6" Rung Spacing

- 9" Rung Spacing

- 12" Rung Spacing

- Ventilated/Trough

- 18" Rung Spacing

- Solid Flat BottomSF

Bottom Type Length Width

06

09

12

18

- 6"

- 9"

- 12"

- 18"

24

30

36

- 24"

- 30"

- 36"

This identifies the specifictray design and is used asa catalog number prefixfor straight sections,fittings, and accessories.

Rung Options

SL - With Slots†

Leave Blankfor No Slots

Special suffixesare also used

here to indicatealternate rung

designs.

(See page 133)

†Rung slots are .31" wide x .75" long on 1" centers. Slotted rungs are normally located every

second or third rung, alternating with solid rungs. Trays with slotted rungs only are also available.

0020

0024

0030

0040

- 20'-0"

- 24'-0”

- 30'-0”

- 40'-0"

MATERIAL

LOAD

DEPTH

NEMA

CLASS

STEEL

RAIL

HEIGHT

8" 6" EXCEEDS 20CLONG SPAN/HEAVY DUTY

6"8"

2 1"4

Arc-welded.Construction:

6”8”

2 1”4

6”8”

2 1”4

0.56 0.88 1.27 1.49 1.98 2.47 2.72 3.31

316 203 141 120 90 68 60 48

Note: lighter-duty 8"-high tray systems also available. Contact your PW customer representative for assistance.

Page 21: Catalogo de Bandeja Electrica

Metallic Cable Tray and Channel62 PW Industries, Inc.

MC

TC

ETA

LLIC

ABLE

RAY

AN

DH

AN

NEL

S S STEEL TRAIGHT ECTIONS

PWINDUSTRIES.COM

LADDER

Rungs are 1-5/8" wide, spaced on 6", 9", 12", or 18" centers.

Available with slotted rungs for cable ties.

System Number

1953

SAFE

LOAD (lbs/ft)

DEFLECTION

(inches)

SUPPORTSPAN (feet)

Safe loads and deflections are based on simple beam supports and a safety factorof 1.5 per NEMA Standard VE1.

When cable trays are supported in continuous spans, the mid-span tray deflectionis approximately 60% of the values shown.

Load data is for the tray side rails only. See page137 for safe load limitations of tray rungs and bottoms.

SAFE LOAD AND DEFLECTION DATA

20 24 26 30 36 40 45 50

Supplied in pairs with cadmiumplated steel hardware.

See page 94 for upgradeoptions and more information.

Necessary connectors aresupplied with all trays. Extra

connectors for field cuts or sparesmust be ordered separately.

Catalog No. (pr.)

-1302-02(System No.)

1973

SOLID BOTTOM

System Number

1963

VENTILATED/TROUGH

System Number

Rungs are 4" wide, spaced on 8" centers for straight sections.

Fittings have 1-5/8" wide rungs spaced on 5" centers.

Available with slotted rungs for cable ties.

Tray bottoms are flat sheet placed on top of

1-5/8" wide rungs located on 12" centers.

TRAY CONNECTORS

I-Beam Cable Trays

for Long Spans and Heavy Loads

All systems are hot-dip galvanizedafter fabrication per ASTM A123.Finish:

Made from C-Channels with1-3/4" flanges facing out. See pages 66-90.Fittings:

Made from W8x10 structural-steel I-Beams per ASTM A36.Side Rails:

Minimum quantities mayapply; Contact PW for current lead times.Availability:

Fittings for the tray systemson this page have 5" tangents.

FITTING SERIES

2

CLASSIFIEDAS AN EQUIPMENT

GROUNDING CONDUCTOR

PER N.E.C. 392.7

U.L. AREA AMPS

6001.50 in2

See pages 66-90 for fittingdimensions and part numbers.

UR

Straight Section Catalog Numbers:

Example: 1 2 - 1 9 5 3 - 0 0 4 0 - 3 6 - S L

Tray System Number

06

09

12

18

VT

- 6" Rung Spacing

- 9" Rung Spacing

- 12" Rung Spacing

- Ventilated/Trough

- 18" Rung Spacing

- Solid Flat BottomSF

Bottom Type Length Width

06

09

12

18

- 6"

- 9"

- 12"

- 18"

24

30

36

- 24"

- 30"

- 36"

This identifies the specifictray design and is used asa catalog number prefixfor straight sections,fittings, and accessories.

Rung Options

SL - With Slots†

Leave Blankfor No Slots

Special suffixesare also used

here to indicatealternate rung

designs.

(See page 133)

†Rung slots are .31" wide x .75" long on 1" centers. Slotted rungs are normally located every

second or third rung, alternating with solid rungs. Trays with slotted rungs only are also available.

0020

0030

0040

0050

- 20'-0"

- 30'-0”

- 40'-0”

- 50'-0"

MATERIAL

LOAD

DEPTH

NEMA

CLASS

STEEL

RAIL

HEIGHT

8" 6" EXCEEDS 20CLONG SPAN/HEAVY DUTY

Arc-welded.Construction:

6"8"

4"

6"8"

4"

6"8"

4"

0.98 1.41 1.65 2.20 3.05 3.69 4.60 5.37

360 250 213 160 107 85 66 51

Note: lighter-duty 8"-high tray systems also available. Contact your PW customer representative for assistance.

Page 22: Catalogo de Bandeja Electrica

Metallic Cable Tray and Channel 63PW Industries, Inc.

MC

TC

ETA

LLICA

BLE

RAY

AN

DH

AN

NEL

S S STEEL TRAIGHT ECTIONS

PWINDUSTRIES.COM

LADDER

System Number

1954

Supplied in pairs with cadmiumplated steel hardware.

See page 94 for upgradeoptions and more information.

Necessary connectors aresupplied with all trays. Extra

connectors for field cuts or sparesmust be ordered separately.

Catalog No. (pr.)

-1302-02(System No.)

TRAY CONNECTORS

I-Beam Cable Trays for Extremely Heavy Loads

Fittings for the tray systemson this page have 5" tangents.

FITTING SERIES

2

CLASSIFIEDAS AN EQUIPMENT

GROUNDING CONDUCTOR

PER N.E.C. 392.7

U.L. AREA AMPS

6001.50 in2

See pages 66-90 for fittingdimensions and part numbers.

UR Straight Section Catalog Numbers:

Example: 0 9 - 1 9 5 4 - 0 0 4 0 - 3 6

Tray System Number

- 9" Rung Spacing09

Bottom Type Length Width

06

09

12

18

- 6"

- 9"

- 12"

- 18"

24

30

36

- 24"

- 30"

- 36"

This identifies the specifictray design and is used asa catalog number prefixfor straight sections,fittings, and accessories.

0020

0030

0040

0050

- 20'-0"

- 30'-0”

- 40'-0”

- 50'-0"

MATERIAL

LOAD

DEPTH

NEMA

CLASS

STEEL

RAIL

HEIGHT

10" 5" EXCEEDS 20CLONG SPAN/HEAVY DUTY

SAFE

LOAD (lbs/ft)

DEFLECTION

(inches)

SUPPORTSPAN (feet)

Safe loads and deflections are based on simple beam supports and a safety factorof 1.5 per NEMA Standard VE1.

When cable trays are supported in continuous spans, the mid-span tray deflectionis approximately 60% of the values shown.

Load data is for the tray side rails only. See page137 for safe load limitations of tray rungs and bottoms.

SAFE LOAD AND DEFLECTION DATA

30 35 40 45 50

4

10"

4"

5"8

Minimum quantities mayapply; Contact PW for current lead times.

Availability:

Hot-dip galvanized afterfabrication per ASTM A123.

Finish:

Arc-welded.Construction:

W10x15 Structural steelI-beams per ASTM A36.

Side Rails:

C5x6.7 Structural steel channelsper ASTM A36 on 54" centers and 1"wide box channels on 9" centers.

Rungs:

2" x 2" Steel angles.Diagonal Braces:

2.16 3.26 3.94 4.87 5.62

367 268 212 164 124

Note: lighter-duty 10"-high tray systems also available. Contact your PW customer representative for assistance.

Page 23: Catalogo de Bandeja Electrica

STAINLESS STEELCABLE TRAY SYSTEMS

Safe Load:

Metric Units:

Allowable cable load in lbs. per linear footased on simple beam type supports with a safety factor of 1.5,

per Safe load data is based on the performance of the trayside rails only. For heavy loads on short spans, it is possible that the traybottom capabilities will be less than the values shown for the tray side rails.Contact PW for information on bottom limitations for stainless steel trays.

uniformlydistributed, b

NEMAStd. VE1.

To convert pounds per foot to kilograms per meter multiplyby 1.488. To convert feet to meters multiply by 0.305.

To convert safe load data to reflect a safety factor of 2.0, multiply the loadshown by 0.75.

NEMA Class: Load/Span rating for the load carryingcapability of the tray system, based on a 1.5 safetyfactor and tested per NEMA Std. VE1. See the safeload data chart on the following page to comparetray performance across various support spans.

Tray System Number:

System Number

Identifies a specific PW cable tray design includingthe material, type, rail height, style, bottom and NEMA Load Class. The

is used in the catalog numbering system for straightsections, fittings and accessories. See page 10 for more information on thecatalog numbering system.

Rail Height: Nominal overall height of the tray side rails.

Tray Types: The ladder, ventilated/trough and solid bottom type cable traysystems shown in this chart are standard PW designs that are in accordancewith NEMA Std. VE1 guidelines. See pages 6-7 for construction details onstandard and alternate PW cable tray designs.

Load Depth: Nominal interior depth of the cable traythat is available for fill. The nominal height and depth isdefined by NEMA Std. VE1 as being within 3/8" of theactual exact dimension.

Deflection:

Tray Lengths:

Availability:

load vs. deflectioninformation for specific stainless steel cable tray systems.

Standard tray lengths are 12' and 24'. 10', 20'and custom tray lengths are available. Contact PW for currentlead times on non-standard lengths.

Note: Straight tray lengths should be equal to or greater than thecable tray support spacing when installed, per NEMAStandards.

Stainless steel trays over 12' long may be limited,and may require greater lead times. Contact PW for currentavailability of all stainless steel tray systems.

Visit forwww.pwindustries.com

FLANGE IN FLANGE OUT

LADDER

FLANGE IN FLANGE IN

VENTILATED/TROUGH SOLID BOTTOM

CABLE TRAY SYSTEM NUMBERS

RAIL

HEIGHT

LOAD

DEPTH

NEMA

CLASS

STAINLESS STEEL

CABLE TRAYS

4" 3"

5"

6"

7"

4"

5"

6"

20A,16B

20B,16C

20C

20B,16C

20C

12B

12C,16A

20B,16C

20C

12B

12C,16A

12B

12C,16A

12B

12C,16A

20B,16C

20C

3408

3409

3416

3417

3457

3D27

3460

3D18

Type 304

Stainless

Steel

Type 316

Stainless

Steel

Type 304

Stainless

Steel

Type 316

Stainless

Steel

Type 304

Stainless

Steel

Type 316

Stainless

Steel

Type 304

Stainless

Steel

Type 316

Stainless

Steel

3476

3456

3406

3D85

3D92

3445

3D63

3D93

3407

3D82

3D58

3446

3504

3505

3514

3515

3557

3559

3547

3500

3603

3604

3620

3621

3639

3640

3688

3F71

3734

3735

3738

3739

3708

3709

3728

3729

3551

3587

3594

3593

3550

3592

3582

3583

3F67

3645

3F85

3F35

3F68

3F58

3F66

3F61

3701

3714

3723

3724

3754

3722

3756

3760

3742

3743

3746

3747

3697

3698

3676

3F37

3744

3745

3748

3749

3692

3693

3683

3653

3772

3773

3776

3777

3685

3F74

3681

3682

3774

3775

3778

3779

3684

3696

3F77

3680

3D97

3D88

3D87

3440

3D89

3441

3442

3439

3443

3444

3E10

3E11

3E20

3E21

3E12

3E13

3E22

3E23

3498

3473

3D73

3D91

3D74

3449

3450

3475

3484

3485

3E30

3E31

3E40

3E41

3E32

3E33

3E42

3E43

Metallic Cable Tray and Channel64 PW Industries, Inc.

MC

TC

ETA

LLIC

ABLE

RAY

AN

DH

AN

NEL

S S S STAINLESS TEEL TRAIGHT ECTIONS

System numbers

efer to the appropriate catalog pages

are shown for each type of standard stainlesssteel cable tray. For detailed information and part numbers forspecific tray systems, please r .

LOAD

DEPTHRAIL

HEIGHT BOTTOM

SIDE RAIL

8A

8B

8C

12 ft.

SAFE

WORKING

LOAD

50 lbs/ft

75 lbs/ft

100 lbs/ft

12A

12B

12C

8 ft.

16A

16B

16C

20 ft.

20A

20B

20C

16 ft.

SUPPORT SPAN

NEMA CLASS

PWINDUSTRIES.COM

Page 24: Catalogo de Bandeja Electrica

RAIL

HEIGHT

LOAD

DEPTH

NEMA

CLASS

4" 3" 20A,16B

20B,16C

20C

5" 4"20B,16C

20C

6" 5"

12B

12C,16A

20B,16C

20C

7" 6"

12B

12C,16A

12B

12C,16A

12B

12C,16A

20B,16C

20C

STAINLESS STEELCABLE TRAY SYSTEMS

SAFE LOAD DATA (lbs/ft)

475

625

844 304

400

211

278

155

204

119

156

76

100

61

81

50

66

300

400

525

719

933 336

460

233

319

171

235

131

180

104

142

84

115

68

93

53

73

316

420

338

488

625

600

867

216

312

400

150

217

278

110

159

204

84

122

156

67

96

123

54

78

100

63

81

52

66

169

225

108

144

75

100 71 52

94

123

178

236

114

151

79

105 74 55

300

400

169

225

108

144

75

100

53

71 52

468

719

833 208

319

153

235

117

180

93

142

50

76

300

460

75

115

61

93

6

SUPPORT SPAN (feet)

8 10 12 14 16 18 20 22 24

332

444

187

250

120

160

83

111 78 58

STAINLESS STEEL

CABLE TRAYS

Supplied in pairs with type 316stainless steel hardware.

STAINLESS STEELTRAY CONNECTORS

Catalog No. (pr.)

-1302-11(System No.)

(NEMA Classes 12B & 12C)

Series 1 Connectors

(NEMA Classes 20A, 20B & 20C)

Series 2 Connectors

Fittings: See catalog pages 66-90 for fitting types and dimensions. Series 1 cable ray systems(NEMA Classes 12B & 12C) have 2" tangents beyond curvature. Series 2 cable tray systems(NEMAClasses 20A, 20B & 20C) have 5" tangents beyond curvature.

Covers: See page 91. Series 1 tray systems (NEMA Classes 12B & 12C) have 1" top side railflanges. Series 2 tray systems (NEMAClasses 20A, 20B & 20C) have 1-3/4" top side rail flanges.

Accessories: Most accessory items shown on pages 94-107 are available in stainless steel. Toorder, use a stainless steel in the catalog number for the accessory.System Number

Stainless Steel Straight Section Catalog Numbers:

Example: 0 9 - 3 4 0 8 - 0 0 1 2 - 2 4 - S L

Tray System Number

06

09

12

18

VT

- 6" Rung Spacing

- 9" Rung Spacing

- 12" Rung Spacing

- Ventilated/Trough

- 18" Rung Spacing

- Solid Flat BottomSF

Bottom Type Length

0010

0020

0024

- 10'-0"

- 20'-0"

- 24'-0"

0012 - 12'-0"

Width

06

09

12

18

- 6"

- 9"

- 12"

- 18"

24

30

36

- 24"

- 30"

- 36"

Rung Options

Slotted Rungs areavailable for all PW

stainless steel Ladderand Ventilated/Trough

type cable trays.

Metallic Cable Tray and Channel 65PW Industries, Inc.

MC

TC

ETA

LLICA

BLE

RAY

AN

DH

AN

NEL

S S S STAINLESS TEEL TRAIGHT ECTIONS

The Safe Load Data chart compares the performance of standard PW stainlesssteel cable trays across a wide range of support spans. If a load is not shown fora given span, that tray system is not recommended for use on the span.

†Rung slots are .31" wide x .75" long on 1" centers. Slotted rungs are normally located every

second or third rung, alternating with solid rungs. Trays with slotted rungs only are also available.

SL - With Slots†

Leave Blankfor No Slots

This identifies the specifictray design and is used asa catalog number prefixfor straight sections,fittings, and accessories.

Necessary connectors aresupplied with all trays. Extra

connectors for field cuts or sparesmust be ordered separately.

PWINDUSTRIES.COM