catalogo

40
BN-CC April 2007 (Replaces BNC-04, 08/04) REFRIGERATION PRODUCTS Condensed Catalog

Upload: alfonso-medina

Post on 01-Dec-2015

105 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: Catalogo

BN-CC April 2007

(Replaces BNC-04, 08/04)

RefRigeRation PRoductsCondensed Catalog

Page 2: Catalogo

�© 2007 Heatcraft Refrigeration Products LLC

Page 3: Catalogo

PRo� Packaged Refrigeration system .................................................... 21

Bohnmizer® split systems .......................................................................... 22

condensing units

Model BH Indoor or Outdoor Installation

with Hermetic Compressor ............................................................... 23

Model BZ Indoor or Outdoor Installation

with Scroll® Compressor ..................................................................... 23

Model BS Indoor or Outdoor Installation

with Semi-Hermetic Compressor .................................................... 24

Models BD, BZ Indoor or Outdoor Installation

with Discus® or Scroll® Compressor ............................................... 25

Models HWN, ZWN Remote Water-Cooled Units

with Hermetic or Scroll® Compressor ............................................ 26

Model SWN Indoor Water-Cooled ......................................................... 27

Model SRN Remote Indoor Compressor .............................................. 28

Models BBV, BLV 12 - 40 HP Air-Cooled .............................................. 29

Models JBD, JLD, JDDS Outdoor Dual Compressor .......................... 30

air-cooled condensers

Model DVT Direct-Drive Air-Cooled...................................................... 31

Model BNE Monarch Series ..................................................................... 32

Models BNQ, BNX Ambassador Series ................................................. 33

Models BNL, BNH Ambassador Series .................................................. 34

Model BVF Belt Drive Ambassador Series........................................... 35

fluid coolers

Model BFF Belt Drive................................................................................. 36

Models BFH & DFT Direct-Drive ............................................................. 37

More from Bohn Refrigeration

FlexPack™ ...................................................................................................... 38

ServiceMate™ ............................................................................................... 38

Energy Solutions® ....................................................................................... 38

table of contents

Reach-in evaporators

Model TA Thin Profile Air Defrost ............................................................ 4

Model TL Thin Profile Electric Defrost .................................................... 4

Model C High Profile Air Defrost ............................................................. 5

Model VA V-Profile Air Defrost ................................................................. 5

Model BB Back Bar ....................................................................................... 6

Model KMK Standard Mullion ................................................................... 6

Model RAMK Reverse Air Mullion ............................................................ 6

Model BTO Twin Flow ................................................................................. 7

Model U Dual Air .......................................................................................... 7

Models LTA, LTL Extended Thin Profile Unit Cooler ........................... 7

Walk-in units evaporators

Model ADT Low Profile Air Defrost ......................................................... 8

Models LET, LLE Low Profile Electric Defrost ....................................... 8

Model HGT Low Profile Hot Gas Defrost ............................................... 9

Model LO Low Velocity Air Defrost ......................................................... 9

Model LOD Low Velocity Electric Defrost ........................................... 10

Model LOG Low Velocity Hot Gas Defrost .......................................... 10

Model WK Low Air Flow Air Defrost ..................................................... 11

Model WKE Low Air Flow Electric Defrost .......................................... 11

Model WKG Low Air Flow Hot Gas Defrost ........................................ 12

Model HR Radial Aire® .............................................................................. 12

Model SM Center Mount Air Defrost .................................................... 13

Model SME Center Mount Electric Defrost ......................................... 13

Model BMA Medium Profile Air Defrost .............................................. 14

Models BME, BML Medium Profile Electric Defrost.......................... 14

Models BMG, BMF Medium Profile Hot Gas Defrost........................ 15

Warehouse evaporators

Model BHA High Profile Air Defrost ..................................................... 16

Models BHE, BHL High Profile Electric Defrost .................................. 17

Models BHG, BHF High Profile Hot Gas Defrost ................................ 18

Ripening Room Refrigeration system

Model RU Ripening Room ....................................................................... 19

Beacon ii™ Refrigeration system ........................................................... 20

Page 4: Catalogo

thin Profile air defrost unit coolersModel ta is a thin unit that mounts in the top of a refrigerator, making the entire top shelf area usable. The attractive low silhouette makes the Top-Aire particularly desirable for display-type refrigerators. It can also be used in back bars, under counter cabinets or wherever space is at a premium.

Drain fitting is at 45° so drain can be run through the back or bottom of refrigerator. Room for expansion valve inside so that it is out of sight. Model TA is available with BOHN-KOTE® coil for corrosion protection (use model designation TAK). Also features sweat inlet connection to reduce leaks.

Reach-in evaporators

thin Profile electric defrost unit coolersModel tL low temperature unit cooler has a completely automatic defrost system. Mounted in the top of a refrigerator, its extremely compact cabinet makes it possible to utilize the entire top shelf area for storage. With a normal operating range of 15°F to –20°F, this unit is ideally suited for such applications as commercial freezers, ice cream boxes, bakery freezers and dual-temp reach-in boxes. Defrosting is accomplished with the unique BOHN-EL® electric defrost system. Mechanical contact is provided between the heater elements and the drain pan, ensuring a warm pan during the defrost cycle.

Sufficient space is provided to mount the expansion valve within the cabinet. Systems for both 115 volt and 208-230 volt operation are available. Also features sweat inlet connection to reduce leaks.

* These models use external equalized expansion valve

* These models use external equalized expansion valve

taModel

BtuH10°ftd

cfMMotor dimensions

(in.)connections

(in.) approx.net Wt.

(lbs.)Qty. 115/1total fLa

�08-��0/1total fLa L H d Liquid

odsuction

iddrain

odTA10 1,000 120 1 0.8 0.4 16-1/2 4-1/2 13-1/2 3/8 3/8 1/2 10TA13 1,300 170 2 1.6 0.8 20-1/2 4-1/2 13-1/2 3/8 3/8 1/2 13TA17 1,700 210 2 1.6 0.8 24 4-1/2 14-1/2 3/8 3/8 1/2 17TA23 2,300 330 3 2.4 1.2 31-5/8 4-1/2 14-1/2 3/8 3/8 1/2 23TA30 3,000 360 3 2.4 1.2 40 4-1/2 14-1/2 3/8 1/2 1/2 26TA43* 4,300 540 4 3.2 1.6 53-3/8 4-1/2 14-1/2 1/2 5/8 1/2 36TA55* 5,500 650 5 4.0 2.0 53-3/8 6-3/4 14-1/2 1/2 5/8 1/2 45

tLModel

BtuH10°f td

-10°f sstcfM

Motor Heater dimensions(in.)

connections(in.) approx.

net Wt.(lbs.)Qty. 115/1

total fLa��0/1

total fLa Watts 115/1amps

��0/1amps L H d Liquid

odsuction

iddrain

odTL09 900 110 1 0.8 0.4 475 4.1 2.1 16-1/2 4-1/2 13-1/2 3/8 3/8 1/2 10TL12 1,200 210 2 1.6 0.8 600 5.2 2.6 20-1/2 4-1/2 13-1/2 3/8 1/2 1/2 15TL16 1,600 210 2 1.6 0.8 700 6.1 3.0 24 4-1/2 14-1/2 3/8 1/2 1/2 19TL21 2,100 240 1 1.0 0.5 1,100 9.6 4.8 24 6-3/4 16-1/2 3/8 1/2 1/2 19TL28 2,800 335 3 - 1.2 1,430 - 5.7 31-5/8 6-3/4 14-1/2 3/8 1/2 1/2 22TL35* 3,500 420 2 - 1.0 1,600 - 7.0 38-3/8 6-3/4 16-1/2 1/2 5/8 1/2 31TL53* 5,300 595 3 - 1.5 1,950 - 8.5 49-1/8 6-3/4 16-1/2 1/2 7/8 1/2 45

Page 5: Catalogo

5

V-Profile air defrost unit coolersModel Va is a deluxe unit designed for use in small reach-ins, back bar and under counter refrigerators, and many other applications where a small, compact unit is required. The thermal expansion valve mounts inside of the unit. The unit can be mounted from the ceiling or off the back or end walls, or can be used in mullion application. VA is available with BOHN-KOTE® coil for corrosion protection (use model designation VAK). Also features sweat inlet connection to reduce leaks.

High Profile air defrost unit coolersModel c is ideal for refrigerated reach-ins. It mounts to the top of the refrigerator and discharges cold air against the back wall. With this air flow pattern, the air is not blasted on the product, but is diffused along the back wall and then gently drawn across the product as it returns to the unit; thus, uniform temperatures are maintained throughout the refrigerator. In addition, door sweating and refrigeration loss due to door opening is greatly reduced because the air is not discharged against the doors. Mounting is easy with aluminum hangers that automatically space the unit the correct distance from the back wall. The expansion valve fits inside, out of sight. Model C is available with BOHN-KOTE® coil (designated as model CK) for corrosion protection. Also features sweat inlet connection to reduce leaks.

Reach-in evaporators

* Size 43 uses external equalized expansion valve

c (K)Model

BtuH10°ftd

cfMMotor dimensions

(in.)connections

(in.) approx.net Wt.

(lbs.)Qty. 115/1total fLa

�08-��0/1total fLa L H d Liquid

odsuction

iddrain

odC13 1,300 235 1 1.0 0.5 14-1/4 8-7/8 13-3/4 3/8 3/8 1/2 12C17 1,700 250 1 1.0 0.5 17-1/4 8-7/8 13-3/4 3/8 1/2 1/2 12C23 2,300 265 1 1.0 0.5 22-3/4 8-7/8 13-3/4 3/8 1/2 1/2 17C30 3,000 480 2 2.0 1.0 27-3/4 8-7/8 13-3/4 3/8 1/2 1/2 21C43* 4,300 520 2 2.0 1.0 38 8-7/8 13-3/4 1/2 1/2 1/2 33

VaModel

BtuH10°ftd

cfMMotor dimensions

(in.)connections

(in.) approx.net Wt.

(lbs.)Qty. 115/1total fLa

�08-��0/1total fLa L H d Liquid

odsuction

iddrain

odVA06 600 135 1 0.8 0.4 12-1/2 6-7/8 8-1/8 3/8 3/8 1/2 7VA08 800 130 1 0.8 0.4 12-1/4 6-7/8 8-1/8 3/8 3/8 1/2 7VA12 1,200 265 2 1.6 0.8 18 8 8-1/8 3/8 3/8 1/2 12VA17 1,700 245 1 1.0 0.5 14 9-3/4 10-1/2 3/8 3/8 1/2 9

Page 6: Catalogo

Reach-in evaporators

standard Mullion unit coolersModel KMK is ideal for use in under-counter reach-in refrigeration. The thin-line design allows the unit to be mounted behind a mullion with sufficient clearance for the installation of tray slides. KMK has a unique fan arrangement that allows air to be drawn into the top of the unit, pulling return air from both sides of the mullion. This arrangement allows the coldest air to be in contact with drop-in trays.

The versatile design of the compact mullions is also adaptable for mounting on the back wall or ends of a beverage cooler. The finned coil of KMK is protected by BOHN-KOTE® finish as standard. Also features sweat inlet connection to reduce leaks.

Back Bar unit coolersModel BB, the Bohn Back Bar Unit Cooler, is available in either air or electric defrost. These compact, wall-mounted units are suitable for 35°F to 40°F (BBM medium temp models) and 0°F to -10°F (BBL low temp models) under-counter reach-in fixtures. Motors are thermally protected and lifetime lubricated. Fan blades and guards are molded from corrosion-proof Lexan®. Housing is made of grained aluminum for long life and easy cleaning. Also features sweat inlet connection to reduce leaks.

Reverse air Mullion unit coolersModel RaMK is ideal for use in under-counter reach-in refrigeration. The thin-line design allows the unit to be mounted behind a mullion with sufficient clearance for the installation of tray slides. RAMK or Reverse Air Mullion draws air through the coil at the bottom and discharges the cooled air out the top. This arrangement allows the coldest air to be in contact with drop-in trays.

The versatile design of the compact mullions is also adaptable for mounting on the back wall or ends of a beverage cooler. The finned coil of RAMK is protected by BOHN-KOTE® finish as standard. Also features sweat inlet connection to reduce leaks.

All units have 3/8” OD suction, 1/2” OD sweat inlet and 1/2” OD Drain

BBModel

BtuH10°ftd

cfMMotor Heater dimensions

(in.)approx.net Wt.

(lbs.)Qty. HP 115/1total fLa

�08-��0/1total fLa Watts 115/1

amps�08-��0/1

amps L H d

BBL10 1,000 90 1 1/150 0.8 0.4 275 2.7 1.4 19-3/4 14 5-1/2 13BBM11 1,100 90 1 1/150 0.8 0.4 - - - 19-3/4 14 5-1/2 12BBL15 1,500 180 2 1/150 1.6 0.8 350 3.5 1.7 26-1/4 14 5-1/2 15BBM16 1,600 180 2 1/150 1.6 0.8 - - - 26-1/4 14 5-1/2 14

KMKModel

BtuH10°ftd

cfMMotor dimensions

(in.)connections

(in.) approx.net Wt.

(lbs.)Qty. 115/1total fLa

�08-��0/1total fLa L H d Liquid

odsuction

oddrain

odKMK13 1,300 180 2 1.6 0.8 15-5/8 17-3/4 5-5/8 3/8 3/8 5/8 15KMK17 1,700 170 2 1.6 0.8 15-5/8 19-3/4 5-5/8 3/8 3/8 5/8 17KMK23 2,300 255 3 2.4 1.2 22 19-3/4 5-5/8 3/8 1/2 5/8 23

RaMKModel

BtuH10°ftd

cfMMotor dimensions

(in.)connections

(in.) approx.net Wt.

(lbs.)Qty. 115/1total fLa

�08-��0/1total fLa L H d Liquid

odsuction

oddrain

odRAMK13 1,300 180 2 1.6 0.8 15-5/8 17-3/4 5-5/8 3/8 3/8 5/8 15RAMK17 1,700 170 2 1.6 0.8 15-5/8 19-3/4 5-5/8 3/8 3/8 5/8 17RAMK23 2,300 255 3 2.4 1.2 22 19-3/4 5-5/8 3/8 1/2 5/8 23

Page 7: Catalogo

twin-flow unit coolersModel Bto twin-flow unit cooler is a compact two-way design with medium velocity airflow. The unit is mounted flush to the ceiling and draws air in through the fan and discharges out both sides. The air pattern reduces air loss when doors are opened and the medium velocity reduces product drying. Twin-flow units are for applications of 35˚F and higher. Box temperatures are kept more constant throughout and fresh products last longer. Seven sizes are available with BTUH from 900 to 5,500 at 10˚TD. The BTO is available with BOHN-KOTE® corrosion protection (use model designation BTOK). Also features sweat inlet connection to reduce leaks.

dual air unit coolersModel u unit cooler is used wherever a small, compact unit is required, such as salad boxes, back bars and direct-draw boxes. It can be mounted on the ceiling or wall. The Model U unit draws air in through the front and discharges it out both sides to ensure proper distribution of cool air and maintain a uniform box temperature. Also features flare connections. This is the original dual air flow unit!

U is available with BOHN-KOTE® coil for corrosion protection (use model designation UK).

Reach-in evaporators

* These models use external equalized expansion valves

extended thin Profile unit coolerModels Lta, LtL unit coolers are the most compact designed unit for reach-in display cases. The unit’s low height design allows the unit to ‘hide’ at the top of the cooler, giving the case a cleaner look and allows for more room for shelves and product. These units have front-access end panels for easy access to refrigerant and electrical compartments, along with modular front-access panels that make it easy to access the motors. Internally enhanced tube design provides increased unit performance.

Better performance, easy installation, servicing and the quality of Bohn makes this unit the perfect fit for your display case needs.

Bto (K)Model

BtuH10°ftd

cfMMotor dimensions

(in.)connections

(in.) approx.net Wt.

(lbs.)Qty. 115/1total fLa

�08-��0/1total fLa L H d inlet

odsuction

iddrain

odBTO09 900 130 1 0.8 0.4 19-1/8 4-7/8 16-1/8 1/2 1/2 1/2 9BTO13 1,300 240 2 1.6 0.8 19-1/8 5-3/4 16-1/8 1/2 1/2 1/2 11BTO18 1,800 255 1 1.0 0.5 19-1/8 5-3/4 16-1/8 1/2 1/2 1/2 12BTO25* 2,500 460 2 2.0 1.0 26-1/8 6-3/4 18-1/8 1/2 1/2 1/2 19BTO35* 3,500 425 2 2.0 1.0 26-1/8 6-3/4 18-1/8 1/2 1/2 1/2 20BTO45* 4,500 550 2 2.0 1.0 29-1/8 9-1/4 21-1/8 1/2 1/2 5/8 29BTO55* 5,500 730 1 2.1 1.1 29-1/8 8-1/2 21-1/8 1/2 1/2 5/8 29

u (K)Model

BtuH10°ftd

cfMMotor dimensions

(in.)connections

(in.) approx.net Wt.

(lbs.)Qty. 115/1total fLa

�08-��0/1total fLa L H d Liquid

fnsuction

iddrain

odU09 850 190 1 0.45 0.55 11-1/2 8-1/2 8-7/8 1/2 3/8 1/2 8U12 1,150 250 1 0.45 0.55 17-1/2 8-1/2 8-7/8 1/2 3/8 1/2 8U15 1,500 310 1 1.10 0.55 17-1/2 9-1/2 10-7/8 1/2 3/8 1/2 12

Lta air defrost

LtaModel

capacity fan shaded Pole MotorBtuH 10°f td

�5°f sst kW cfM M�H Qty. HP115/1/�0 �08-��0/1/�0

Watts amps Watts ampsLTA053 5,300 1.6 850 1,450 2 1/20 220 3.6 200 2.0LTA079 7,900 2.3 1,350 2,300 3 1/20 330 5.4 300 3.0LTA102 10,200 3.0 1,800 3,100 4 1/20 440 7.2 400 4.0LTA134 13,400 3.9 2,250 3,850 5 1/20 550 9.0 500 5.0LTA172 17,200 5.0 2,550 4,350 6 1/20 660 108 600 6.0

LtL electric defrost

LtLModel

capacity fan shaded Pole Motor defrost HeatersBtuH 10°f td

-10°f sst kW cfM M�H Qty. HP�08-��0/1/�0 �08-��0/1/�0

Watts amps Watts ampsLTL046BA 4,600 1.3 850 1,450 2 1/20 200 2.0 1,100 4.8LTL068BA 6,800 2.0 1,300 2,200 3 1/20 300 3.0 1,650 7.2LTL093BA 9,300 2.7 1,700 2,900 4 1/20 400 4.0 2,200 9.6LTL115BA 11,500 3.4 2,100 3,600 5 1/20 500 5.0 2,750 12.0LTL133BA 13,300 3.9 2,550 4,350 6 1/20 600 6.0 3,300 14.4

Page 8: Catalogo

8

Low Profile air defrost evaporatorsModel adt low profile, air defrost unit coolers are designed for maximum capacity with minimum headroom, space and energy. These units are suitable for use with R-22, R-507, or R-404A. The units are only 15” high and are designed to mount flush with top of the cooler. The ADT cabinet design features easy front access to electrical and refrigeration components. ADT units also feature extended model and capacity offering to better match with Bohn condensing units. Advancements include optional plastic blue fan guard design with wire guards; front-facing electric board for easy access and optimized space in end panels. Improved drain pan design. Motor harness and solenoid harness are easier to access from the bottom of the coil. Solenoid harness comes standard. Available with PSC motor option.

Low Profile electric defrost evaporatorsModels Let/LLe low profile, electric defrost unit coolers offer the same features as the air defrost models above and are also available in 6 or 4 fins per inch models. Available with PSC motor option.

Walk-in evaporators

(with PSC motor option)

(with PSC motor option)

adtModel

BtuH10°ftd

cfMfan Motor

shaded Pole115/1

total fLa

dimensions(in.)

connections(in.) approx.

net Wt.(lbs.)

dia.(in.) Qty. L H d inlet

odsuction

idADT040 4,000 730 12 1 1.8 29-1/2 15 15 1/2 5/8 28ADT052 5,200 700 12 1 1.8 29-1/2 15 15 1/2 5/8 31ADT065 6,500 650 12 1 1.8 29-1/2 15 15 1/2 7/8 34ADT070 7,000 1,460 12 2 3.6 45-1/2 15 15 1/2 7/8 45ADT090 9,000 1,400 12 2 3.6 45-1/2 15 15 1/2 7/8 48ADT104 10,400 1,400 12 2 3.6 45-1/2 15 15 1/2 7/8 49ADT120 12,000 1,300 12 2 3.6 45-1/2 15 15 1/2 7/8 51ADT130 13,000 1,300 12 2 3.6 45-1/2 15 15 1/2 7/8 53ADT140 14,000 2,100 12 3 5.4 61-1/2 15 15 1/2 7/8 63ADT156 15,600 2,100 12 3 5.4 61-1/2 15 15 1/2 7/8 67ADT180 18,000 1,950 12 3 5.4 61-1/2 15 15 1/2 7/8 69ADT208 20,800 2,800 12 4 7.2 77-1/2 15 15 1/2 1-1/8 82ADT260 26,000 3,250 12 5 9.0 93-1/2 15 15 1/2 1-1/8 103ADT312 31,200 3,900 12 6 10.8 109-1/2 15 15 1/2 1-1/8 124ADT370 37,000 3,900 12 6 10.8 109-1/2 15 15 1/2 1-3/8 127

Let/LLeModel

BtuH10°ftd

cfMfan Motor

shaded Pole�08-��0/1total fLa

Heaters�08-��0/1

amps

dimensions(in.)

connections(in.) approx.

net Wt.(lbs.)

dia.(in.) Qty. L H d inlet

odsuction

idLet Models � fins Per inch

LET035 3,500 700 12 1 1.0 3.9 29-1/2 15 15 1/2 5/8 24LET040 4,000 700 12 1 1.0 3.9 29-1/2 15 15 1/2 5/8 26LET047 4,700 650 12 1 1.0 3.9 29-1/2 15 15 1/2 5/8 29LET065 6,500 1,400 12 2 2.0 7.8 45-1/2 15 15 1/2 5/8 43LET075 7,500 1,300 12 2 2.0 7.8 45-1/2 15 15 1/2 7/8 45LET090 9,000 1,300 12 2 2.0 7.8 45-1/2 15 15 1/2 7/8 48LET120 12,000 2,100 12 3 3.0 11.7 61-1/2 15 15 1/2 7/8 60LET140 14,000 1,950 12 3 3.0 11.7 61-1/2 15 15 1/2 7/8 62LET160 16,000 2,600 12 4 4.0 15.7 77-1/2 15 15 1/2 1-1/8 81LET180 18,000 2,600 12 4 4.0 15.7 77-1/2 15 15 1/2 1-1/8 84LET200 20,000 3,250 12 5 5.0 19.6 93-1/2 15 15 1/2 1-1/8 101LET240 24,000 3,900 12 6 6.0 23.5 109-1/2 15 15 1/2 1-1/8 121LET280 28,000 3,900 12 6 6.0 23.5 109-1/2 15 15 1/2 1-1/8 124

LLe Models � fins Per inchLLE041 4,100 690 12 1 1.0 3.9 29-1/2 15 15 1/2 5/8 28LLE068 6,800 1,380 12 2 2.0 7.8 45-1/2 15 15 1/2 7/8 44LLE080 8,000 1,380 12 2 2.0 7.8 45-1/2 15 15 1/2 7/8 47LLE102 10,200 2,170 12 3 3.0 11.7 61-1/2 15 15 1/2 7/8 59LLE136 13,600 2,760 12 4 4.0 15.7 77-1/2 15 15 1/2 1-1/8 80LLE170 17,000 3,450 12 5 5.0 19.6 93-1/2 15 15 1/2 1-1/8 100LLE204 20,400 4,140 12 6 6.0 23.5 109-1/2 15 15 1/2 1-1/8 120LLE235 23,500 4,140 12 6 6.0 23.5 109-1/2 15 15 1/2 1-1/8 123

Page 9: Catalogo

Low Profile Hot gas defrost evaporators

Model Hgt low profile, hot gas defrost unit coolers offer the same features as the air defrost models and are available in 6 or 4 fins per inch models. Available with PSC motor option.

Low Velocity air defrost unit coolersModel Lo (Lo-Aire®) features very low coil face velocity, yet provides positive, quiet air movement. This combination ensures even box temperatures and high humidity at the same time.

Lo-Aire® unit coolers equal or outperform gravity coils, but are far more economical to install. Their low, narrow construction is designed for installation between rail beams in meat storage and aging rooms. The high humidity characteristics minimize shrinkage and dehydration of produce.

Model LO has been designed for the attractive appearance and easy cleaning necessary in food processing. A double drain pan system eliminates sweating problems, and the rust-free, all-aluminum white case ensure the long-lasting professional look needed in customer areas or work rooms. Available with PSC motor option.

Walk-in evaporators

(with PSC motor option)

(with PSC motor option)

† PSC motors

HgtModel

BtuH10°ftd

cfM

fan Motorshaded Pole

total fLa

dimensions(in.)

connections(in.) approx.

net Wt.(lbs.)

dia.(in.) Qty.

115/1 �08-��0/1 L H d inletodf

suctionid

Hgt Models � fins Per inchHGT035 3,500 700 12 1 1.8 1.0 29-1/2 15 15 5/8 5/8 26HGT040 4,000 700 12 1 1.8 1.0 29-1/2 15 15 5/8 5/8 28HGT047 4,700 650 12 1 1.8 1.0 29-1/2 15 15 5/8 5/8 31HGT065 6,500 1,400 12 2 3.6 2.0 45-1/2 15 15 5/8 5/8 45HGT075 7,500 1,300 12 2 3.6 2.0 45-1/2 15 15 7/8 7/8 47HGT090 9,000 1,300 12 2 3.6 2.0 45-1/2 15 15 7/8 7/8 50HGT120 12,000 2,100 12 3 5.4 3.0 61-1/2 15 15 7/8 7/8 62HGT140 14,000 1,950 12 3 5.4 3.0 61-1/2 15 15 7/8 7/8 64HGT160 16,000 2,600 12 4 7.2 4.0 77-1/2 15 15 7/8 1-1/8 83HGT180 18,000 2,600 12 4 7.2 4.0 77-1/2 15 15 1-1/8 1-1/8 86HGT200 20,000 3,250 12 5 9.0 5.0 93-1/2 15 15 1-1/8 1-1/8 103HGT240 24,000 3,900 12 6 10.8 6.0 109-1/2 15 15 1-1/8 1-1/8 123HGT280 28,000 3,900 12 6 10.8 6.0 109-1/2 15 15 1-1/8 1-1/8 126

Hgt Models � fins Per inchHGT041 4,100 690 12 1 1.8 1.0 29-1/2 15 15 5/8 5/8 30HGT068 6,800 1,380 12 2 3.6 2.0 45-1/2 15 15 5/8 7/8 46HGT080 8,000 1,380 12 2 3.6 2.0 45-1/2 15 15 5/8 7/8 49HGT102 10,200 2,170 12 3 5.4 3.0 61-1/2 15 15 7/8 7/8 61HGT136 13,600 2,760 12 4 7.2 4.0 77-1/2 15 15 7/8 1-1/8 82HGT170 17,000 3,450 12 5 9.0 5.0 93-1/2 15 15 7/8 1-1/8 102HGT204 20,400 4,140 12 6 10.8 6.0 109-1/2 15 15 7/8 1-1/8 122HGT235 23,500 4,140 12 6 10.8 6.0 109-1/2 15 15 1-1/8 1-1/8 125

LoModel

BtuHcfM

Motor dimensions(in.)

connections(in.) approx.

net Wt.(lbs.)10°f

td15°ftd Qty. 115/1

total fLa��0/1

total fLa L H d Liquidod

suctionod

drainod

LO070 7,000 10,500 1,200 2 3.6 1.8 83 14 23-1/4 1/2 7/8 7/8 178LO087 8,700 13,050 1,200 2 3.6 1.8 83 14 23-1/4 1/2 7/8 7/8 189LO118 11,800 17,700 1,300 2 3.6 1.8 111 14-1/2 23-1/4 1/2 7/8 7/8 262LO125 12,500 18,750 1,300 2 3.6 1.8 111 14-1/2 23-1/4 1/2 7/8 7/8 264LO150 15,000 22,500 1,900 2 3.6 1.8 114 16 23-1/4 1/2 1-1/8 7/8 280LO165 16,500 24,750 1,900 2 3.6 1.8 114 16 23-1/4 1/2 1-1/8 7/8 285LO189 18,900 28,350 2,400 2 2.8† 1.4† 134 16-1/2 23-1/4 1/2 1-1/8 7/8 298LO225 22,500 33,750 2,700 2 2.8† 1.4† 153 16-1/2 23-1/4 1/2 1-1/8 7/8 366LO266 26,600 39,900 3,200 2 2.8† 1.4† 158 20 28-1/4 1/2 1-3/8 7/8 405

Page 10: Catalogo

10

Walk-in evaporators

Low Velocity electric defrost unit coolersModel Lod (Lo-Aire®) is perfect for storage of fresh meats and features very low face velocity, but provides positive, quiet air movement. Designed for use from 28°F to 34°F, these units may be used for floral boxes, vegetable and fruit storage rooms, dough-retarding storage, or any other application where freshness is important. The high efficiency, fast electric defrost allows the LOD to maintain room temperature and minimize incidence of sliming and the formation of bacterial growth.

The model LOD features a heavy gauge all-aluminum casing with white, rust-free finish, and a double drain pan system to eliminate sweating problems. Available with PSC motor option.

Low Velocity Hot gas defrost unit coolersModel Log (Lo-Aire® ) has very low face velocity, yet provides positive, quiet air movement. This combination ensures even box temperatures with high humidity. The hot gas defrost is available factory-installed or as a field installed kit, making LOG a good choice for (28°F to 34°F) applications where positive defrost is required. The low air movement ensures even temperatures, which is very important for product freshness. The unit is ideal for meat storage, floral boxes, vegetable and fruit storage or dough-retarding storage.

Model LOG has heavy gauge all-aluminum casings with a white, rust-free finish for an attractive appearance. Strong aluminum hanger bars are slotted for easy installation, and a double drain pan with electric heaters in the inner pan eliminate sweating or condensate flow problems. Available with PSC motor option.

(with PSC motor option)

(with PSC motor option)

† PSC motors

LodModel

BtuHcfM

Motor Heater dimensions(in.)

connections(in.) approx.

net Wt.(lbs.)10°f

td15°ftd Qty. ��0/1

total fLa Watts ��0/1amps L H d Liquid

odsuction

oddrain

odLOD070 7,000 10,500 1,200 2 1.8 2,800 11.5 83 14 23-1/4 1/2 7/8 7/8 178LOD087 8,700 13,050 1,200 2 1.8 2,800 11.5 83 14 23-1/4 1/2 7/8 7/8 189LOD118 11,800 17,700 1,300 2 1.8 4,200 16.7 111 14-1/2 23-1/4 1/2 7/8 7/8 262LOD125 12,500 18,750 1,300 2 1.8 4,200 16.7 111 14-1/2 23-1/4 1/2 7/8 7/8 264LOD150 15,000 22,500 1,900 2 1.8 4,800 16.7 114 16 23-1/4 1/2 1-1/8 7/8 280LOD165 16,500 24,750 1,900 2 1.8 4,800 16.7 114 16 23-1/4 1/2 1-1/8 7/8 285LOD189 18,900 28,350 2,400 2 1.4† 4,800 20.7 134 16-1/2 23-1/4 1/2 1-1/8 7/8 298LOD225 22,500 33,750 2,700 2 1.4† 6,000 24.8 153 16-1/2 23-1/4 1/2 1-1/8 7/8 366LOD266 26,600 39,900 3,200 2 1.4† 6,000 24.8 158 20 28-1/4 1/2 1-3/8 7/8 405

† PSC motors

LogModel

BtuHcfM

Motor dimensions(in.)

connections(in.) approx.

net Wt.(lbs.)10°f

td15°ftd Qty. 115/1

total fLa��0/1

total fLa L H d Liquidod

suctionod

Hot gasod

drainod

LOG070 7,000 10,500 1,200 2 3.6 1.8 83 14 23-1/4 1/2 7/8 1/2 7/8 178LOG087 8,700 13,050 1,200 2 3.6 1.8 83 14 23-1/4 1/2 7/8 1/2 7/8 189LOG118 11,800 17,700 1,300 2 3.6 1.8 111 14-1/2 23-1/4 1/2 7/8 1/2 7/8 262LOG125 12,500 18,750 1,300 2 3.6 1.8 111 14-1/2 23-1/4 1/2 7/8 1/2 7/8 264LOG150 15,000 22,500 1,900 2 3.6 1.8 114 16 23-1/4 1/2 1-1/8 1/2 7/8 280LOG165 16,500 24,750 1,900 2 3.6 1.8 114 16 23-1/4 1/2 1-1/8 1/2 7/8 285LOG189 18,900 28,350 2,400 2 2.8† 1.4† 134 16-1/2 23-1/4 1/2 1-1/8 1/2 7/8 298LOG225 22,500 33,750 2,700 2 2.8† 1.4† 153 16-1/2 23-1/4 1/2 1-1/8 1/2 7/8 366LOG266 26,600 39,900 3,200 2 2.8† 1.4† 158 20 28-1/4 1/2 1-3/8 5/8 7/8 405

Page 11: Catalogo

11

Low air flow air defrost unit coolersModel WK is ideal for floral storage, fresh fruit and vegetables, dough-retarding, fresh meat storage and preparation and many other applications of 35°F and above. The low air flow and quiet fans are classically suited for work-room applications.

The generous coil surface combined with close TD system balance provides high humidity characteristics to minimize product shrinkage and drying. Available with PSC motor option.

Low air flow electric defrost unit coolersModel WKe is ideal for floral storage, fresh fruit and vegetables, dough-retarding, fresh meat storage and preparation and many other applications of 24°F and above. The low air flow and quiet fans are classically suited for work-room applications.

The generous coil surface combined with close TD system balance provides high humidity characteristics to minimize product shrinkage and drying. Available with PSC motor option.

Walk-in evaporators

(with PSC motor option)

(with PSC motor option)

WKeModel

BtuHcfM

Motor Heater dimensions(in.)

connections(in.) approx.

net Wt.(lbs.)10°f

td15°ftd Qty. ��0/1

total fLa Watts ��0/1amps L H d Liquid

odsuction

oddrain

fPtWKE050 5,000 7,500 725 1 1.1 2,000 8.7 53-1/2 8-7/8 26-5/8 1/2 7/8 3/4 75WKE075 7,500 11,250 730 1 1.1 2,400 10.5 75-1/2 8-7/8 26-5/8 1/2 7/8 3/4 108WKE100 10,000 15,000 1,450 2 2.2 2,800 12.2 75-1/2 11-3/8 26-5/8 1/2 7/8 3/4 111WKE130 13,000 19,500 1,470 2 2.2 4,000 17.4 75-1/2 15-1/8 26-5/8 1-1/8 1-1/8 3/4 150WKE155 15,500 23,250 1,460 2 2.2 4,000 17.4 75-1/2 15-1/8 26-5/8 1-1/8 1-1/8 3/4 154WKE180 18,000 27,000 2,130 3 3.3 4,000 17.4 75-1/2 15-1/8 26-5/8 1-1/8 1-1/8 3/4 157WKE210 21,000 31,500 2,840 4 4.4 5,200 22.6 97-1/2 15-1/8 26-5/8 1-1/8 1-1/8 3/4 203WKE270 27,000 40,500 2,800 4 4.4 5,200 22.6 97-1/2 15-1/8 26-5/8 1-3/8 1-3/8 3/4 208WKE340 34,000 51,000 3,500 5 5.5 7,000 30.4 119-1/2 15-1/8 26-5/8 1-3/8 1-3/8 3/4 250

WKModel

BtuHcfM

Motortotal fLa

dimensions(in.)

connections(in.) approx.

net Wt.(lbs.)10°f

td15°ftd

shaded Pole PscL H d Liquid

odsuction

oddrain

fPt115/1 ��0/1 115/1 ��0/1WK050 5,000 7,500 725 2.1 1.1 0.9 0.45 53-1/2 8-7/8 26-5/8 1/2 7/8 3/4 70WK075 7,500 11,250 730 2.1 1.1 0.9 0.45 75-1/2 8-7/8 26-5/8 1/2 7/8 3/4 103WK100 10,000 15,000 1,450 4.2 2.2 1.8 0.9 75-1/2 11-3/8 26-5/8 1/2 7/8 3/4 106WK130 13,000 19,500 1,470 4.2 2.2 1.8 0.9 75-1/2 15-1/8 26-5/8 1-1/8 1-1/8 3/4 145WK155 15,500 23,250 1,460 4.2 2.2 1.8 0.9 75-1/2 15-1/8 26-5/8 1-1/8 1-1/8 3/4 149WK180 18,000 27,000 2,130 6.3 3.3 2.7 1.35 75-1/2 15-1/8 26-5/8 1-1/8 1-1/8 3/4 160WK210 21,000 31,500 2,840 8.4 4.4 3.6 1.8 97-1/2 15-1/8 26-5/8 1-1/8 1-1/8 3/4 193WK270 27,000 40,500 2,800 8.4 4.4 3.6 1.8 97-1/2 15-1/8 26-5/8 1-3/8 1-3/8 3/4 200WK340 34,000 51,000 3,500 10.5 5.5 4.5 2.25 119-1/2 15-1/8 26-5/8 1-3/8 1-3/8 3/4 242

Page 12: Catalogo

1�

Walk-in evaporators

Low air flow Hot gas defrost unit coolersModel WKg is ideal for floral storage, fresh fruit and vegetables, dough-retarding, fresh meat storage/preparation and many other applications of 24°F and above. The low air flow and quiet fans are classically suited for work-room applications.

The generous coil surface combined with close TD system balance provides high humidity characteristics to minimize product shrinkage and drying. Available with high-efficiency PSC motor option.

Radial aire® unit coolersModel HR is the original half-round unit cooler for cold rooms, meat and dairy storage and other 35°F applications. Designed to give more head room and usable space in refrigerated areas, it mounts against the ceiling and directly against the back wall. The fan panel is hinged to a stationary drain trough. This feature allows complete access to the interior of the unit without disconnecting the drain line. The fan panel is sloped toward the back of the unit to provide positive drainage of condensate. The air is drawn in through the fan and discharged radially in a full 180° arc. Here is the unit for those jobs requiring high humidity with gentle air movement distributed throughout the room.

(with PSC motor option)

All units have 1/4” OD external equalization except Model 35

WKgModel

BtuHcfM

Motor dimensions(in.)

connections(in.) approx.

net Wt.(lbs.)10°f

td15°ftd Qty. 115/1

total fLa��0/1

total fLa L H d Liquidod

suctionod

drainfPt

WKG100 10,000 15,000 1,450 2 4.2 2.2 75-1/2 11-3/8 26-5/8 1/2 7/8 3/4 131WKG130 13,000 19,500 1,470 2 4.2 2.2 75-1/2 15-1/8 26-5/8 1-1/8 1-1/8 3/4 170WKG155 15,500 23,250 1,460 2 4.2 2.2 75-1/2 15-1/8 26-5/8 1-1/8 1-1/8 3/4 174WKG180 18,000 27,000 2,130 3 6.3 3.3 75-1/2 15-1/8 26-5/8 1-1/8 1-1/8 3/4 185WKG210 21,000 31,500 2,840 4 8.4 4.4 97-1/2 15-1/8 26-5/8 1-1/8 1-1/8 3/4 223WKG270 27,000 40,500 2,800 4 8.4 4.4 97-1/2 15-1/8 26-5/8 1-1/8 1-3/8 3/4 228WKG340 34,000 51,000 3,500 5 10.5 5.5 119-1/2 15-1/8 26-5/8 1-1/8 1-3/8 3/4 270

HRModel

BtuH10°ftd

cfMMotor dimensions

(in.)connections

(in.) approx.ship Wt.

(lbs.)Qty. 115/1total fLa

��0/1total fLa L H d Liquid

odsuction

oddrain

MfHR035 3,500 650 1 1.65 0.82 35 6-3/4 23-1/4 3/8 1/2 5/8 52HR043 4,300 790 1 1.65 0.82 39 6-3/4 25-1/4 3/8 1/2 5/8 61HR054 5,400 1,090 1 2.50 1.50 39 8-1/4 25-1/4 3/8 5/8 5/8 67HR069 6,900 1,275 1 2.50 1.50 47 8-1/4 29-1/4 3/8 5/8 5/8 81HR087 8,700 1,580 1 3.00 1.35 47 9-3/4 29-1/4 3/8 7/8 5/8 92HR108 10,800 1,980 1 3.00 1.35 47 12-3/4 29-1/4 3/8 7/8 5/8 102HR149 14,900 2,200 1 3.00 1.35 50 12-3/4 30-3/4 3/8 7/8 5/8 126HR180 18,000 2,600 1 3.00 1.35 50 15-3/4 33-3/4 3/8 1-1/8 5/8 147

Page 13: Catalogo

1�

center Mount air defrost unit coolersModel sM units are compact, medium-velocity coolers designed for use in 35°F and above rooms. The low height allows for more head room and allows product to be stacked higher. The center ceiling mount with dual air flow allows shelving and storage of product around all walls.

Also equipped with dual drain pans to prevent sweating, the SM units have a heavy-gauge, grained aluminum cabinet that cleans easily and looks attractive. The PVC coated fan guards won’t rust or rattle.

Ease of installation and service are also part of the design. The panels on the ends quickly remove for complete access to refrigerant components and electrical terminal block, without the need to drop the fan panel/drain pan. Available with PSC motor option.

center Mount electric defrost unit coolers

Model sMe is the compact ceiling mount with only 85/8” height that provides maximum headroom in a commercial freezer. The center mount design allows for product to be stacked all around while air flow distributes evenly throughout the box. SME is designed for –20°F to 34°F and is ideal for tight storage situations.

Standard features include a heavy gauge grained aluminum cabinet that cleans easily and looks attractive. The stainless steel screws prevent rust streaks, and the PVC coated fan guards won’t rust. The SME is designed to be easy to install and service. All the defrost controls are mounted and wired to a terminal board, and panels on either end remove quickly for complete access to the refrigerant components and electrical connection point. A quick-disconnect, waterproof plug and receptacle is supplied with each motor. Available with PSC motor option.

Walk-in evaporators

(with PSC motor option)

(with PSC motor option)

1 All SM coils have 1/4” OD external equalizer connections

sMModel

BtuH10°ftd

cfMMotor dimensions

(in.)connections1

(in.) approx.net Wt.

(lbs.)Qty. 115/1total fLa

��0/1total fLa L H d Liquid

odsuction

oddrain

fPtSM052 5,200 610 1 2.1 1.1 31-1/2 8-5/8 28-13/16 1/2 7/8 3/4 42SM076 7,600 1,300 2 4.2 2.2 53-1/2 8-5/8 28-13/16 1/2 7/8 3/4 64SM090 9,000 1,260 2 4.2 2.2 53-1/2 8-5/8 28-13/16 1/2 7/8 3/4 70SM102 10,200 1,220 2 4.2 2.2 53-1/2 8-5/8 28-13/16 1/2 7/8 3/4 83SM108 10,800 1,950 3 6.3 3.3 75-1/2 8-5/8 28-13/16 1/2 7/8 3/4 105SM134 13,400 1,890 3 6.3 3.3 75-1/2 8-5/8 28-13/16 1/2 7/8 3/4 117SM156 15,600 1,830 3 6.3 3.3 75-1/2 8-5/8 28-13/16 1/2 7/8 3/4 123SM179 17,900 2,520 4 8.4 4.4 97-1/2 8-5/8 28-13/16 1/2 1-1/8 3/4 149SM208 20,800 2,440 4 8.4 4.4 97-1/2 8-5/8 28-13/16 1/2 1-1/8 3/4 164SM249 24,900 3,050 5 10.5 5.5 119-1/2 8-5/8 28-13/16 1/2 1-1/8 3/4 206

1 All SME units have 1/4” OD external equalizer connections and 3/4” FPT drain connections

sMeModel

BtuH fan Motor dimensions(in.)

connections1

(in.) approx.net Wt.

(lbs.)10°ftd

1�°ftd cfM Qty.

�08-��0/1Heaters L H d inlet

odsuction

odshaded Poletotal fLa

Psctotal fLa

SME040 4,000 4,800 610 1 1.1 0.4 5.3 31-1/2 8-5/8 28-13/16 1/2 7/8 90SME054 5,400 6,480 1,300 2 2.2 0.8 8.7 53-1/2 8-5/8 28-13/16 1/2 7/8 120SME065 6,500 7,800 1,260 2 2.2 0.8 8.7 53-1/2 8-5/8 28-13/16 1/2 7/8 120SME090 9,000 10,800 1,950 3 3.3 1.2 10.5 75-1/2 8-5/8 28-13/16 1/2 7/8 160SME130 13,000 15,600 1,830 3 3.3 1.2 15.7 75-1/2 8-5/8 28-13/16 1/2 7/8 174SME174 17,400 20,880 2,440 4 4.4 1.6 20.9 97-1/2 8-5/8 28-13/16 1/2 1-1/8 218

Page 14: Catalogo

1�

Walk-in evaporatorsMedium Profile air defrost unit coolersModel BMa is designed with superior quality and dependable performance. With features like the innovative thermo-flex™ coil design that carries a five-year limited warranty against refrigerant leaks, internal grooved tubing for greater heat transfer efficiency and motors that plug into the wiring harness for easier accessibility, these units provide long life and dependability to your refrigeration application.

With 10,000 to 71,000 BTUH size ranges and a modular design that is only 25 inches high, these unit coolers serve a variety of commercial and industrial applications. PSC motors come standard to help you save energy.

Medium Profile electric defrost unit coolersModels BMe/BML are designed with superior quality and dependable performance. With features like the innovative thermo-flex™ coil design that carries a five-year limited guarantee against refrigerant leaks, internal grooved tubing for greater heat transfer efficiency and motors that plug into the wiring harness for easier accessibility, these units provide long life and dependability to your refrigeration application.

With 10,000 to 62,000 BTUH size ranges and a modular design that is only 25 inches high, these unit coolers serve a variety of commercial and industrial applications. PSC motors come standard to help you save energy.

BMaModel

BtuH10°ftd

cfM

Motortotal fLa

dimensions(in.)

connections1

(in.) approx.net Wt.

(lbs.)115/1 ��0/1 ��0/1 5�5/1 L H d inletodf

suctionodf

BMA130 13,000 2,300 4.0 1.8 1.0 0.75 39-3/10 25 22-7/8 1/2 7/8 115BMA155 15,500 2,200 4.0 1.8 1.0 0.75 39-3/10 25 22-7/8 1/2 1-1/8 123BMA245 24,500 4,600 8.0 3.6 2.0 1.5 67-3/10 25 22-7/8 7/8 1-1/8 134BMA300 30,000 4,400 8.0 3.6 2.0 1.5 67-3/10 25 22-7/8 7/8 1-1/8 148BMA365 36,500 6,900 12.0 5.4 3.0 2.25 95-3/10 25 22-7/8 7/8 1-3/8 200BMA450 45,000 6,600 12.0 5.4 3.0 2.25 95-3/10 25 22-7/8 1-1/8 1-3/8 227BMA510 51,000 9,200 16.0 7.2 4.0 3.0 123-3/10 25 22-7/8 1-1/8 1-5/8 230BMA600 60,000 8,800 16.0 7.2 4.0 3.0 123-3/10 25 22-7/8 1-1/8 1-5/8 255BMA710 71,000 10,500 - 9.0 5.0 3.75 138-3/4 25 22-7/8 1-1/8 1-5/8 285

1 All BMA coils have 1/4” OD external equalizer connections

* 230/31 All BME and BML coils have 1/4” OD external equalizer connections

BMe/BMLModel

BtuH10°ftd

cfM

Motortotal fLa Heater dimensions

(in.)connections1

(in.) approx.net Wt.

(lbs.)��0/1 ��0/1 5�5/1 ��0/1Watts amps L H d inlet

odfsuction

odfBMe Models � fins Per inch

BME101 10,100 2,350 1.8 1.0 0.75 2,730 11.9 39-3/10 25 22-7/8 1/2 7/8 118BME140 14,000 2,250 1.8 1.0 0.75 2,730 11.9 39-3/10 25 22-7/8 1/2 7/8 126BME190 19,000 4,700 3.6 2.0 1.5 5,350 23.3 67-3/10 25 22-7/8 7/8 1-1/8 138BME260 26,000 4,500 3.6 2.0 1.5 5,350 23.3 67-3/10 25 22-7/8 1-1/8 1-3/8 153BME310 31,000 7,050 5.4 3.0 2.25 7,750 33.7 95-3/10 25 22-7/8 1-1/8 1-3/8 210BME390 39,000 6,750 5.4 3.0 2.25 7,750 33.7 95-3/10 25 22-7/8 1-1/8 1-3/8 237BME430 43,000 8,800 7.2 4.0 3.0 10,200 30.5* 123-3/10 25 22-7/8 1-1/8 1-5/8 267BME520 52,000 8,400 7.2 4.0 3.0 10,200 30.5* 123-3/10 25 22-7/8 1-1/8 1-5/8 300BME620 62,000 10,000 9.0 5.0 3.75 11,600 24.7* 138-4/5 25 22-7/8 1-1/8 1-5/8 338

BML Models � fins Per inchBML100 10,000 2,350 1.8 1.0 0.75 2,730 11.9 39-3/10 25 22-7/8 1/2 7/8 125BML165 16,500 4,900 3.6 2.0 0.75 5,350 23.3 67-3/10 25 22-7/8 7/8 1-1/8 136BML220 22,000 4,650 3.6 2.0 1.5 5,350 23.3 67-3/10 25 22-7/8 1-1/8 1-3/8 151BML250 25,000 7,350 5.4 3.0 1.5 7,750 33.7 95-3/10 25 22-7/8 1-1/8 1-3/8 207BML330 33,000 6,975 5.5 3.0 2.25 7,750 33.7 95-3/10 25 22-7/8 1-1/8 1-3/8 234BML370 37,000 9,100 7.2 4.0 2.25 10,200 30.5* 123-3/10 25 22-7/8 1-1/8 1-5/8 262BML440 44,000 8,700 7.2 4.0 3.0 10,200 30.5* 123-3/10 25 22-7/8 1-1/8 1-5/8 295BML530 53,000 10,350 9.0 5.0 3.0 11,600 24.7* 138-3/4 25 22-7/8 1-1/8 1-5/8 332

Page 15: Catalogo

15

Medium Profile Hot gas defrost unit coolersModels BMg/BMf are designed with superior quality and dependable performance. With features like the innovative thermo-flex™ coil design that carries a five-year limited warranty against refrigerant leaks, internal grooved tubing for greater heat transfer efficiency and motors that plug into the wiring harness for easier accessibility, these units provide long life and dependability to your refrigeration application.

With 16,500 to 52,000 BTUH size ranges and a modular design that is only 25 inches high, these unit coolers serve a variety of commercial and industrial applications. BMG models have 6 fins per inch; BMF models have 4 fins per inch. PSC motors come standard to help you save energy.

Walk-in evaporators

1 All BMG and BMF coils have 1/4” OD external equalizer connections

BMg/BMfModel

BtuH10°ftd

cfM

Motortotal fLa Heater dimensions

(in.)connections1

(in.) approx.net Wt.

(lbs.)115/1 ��0/1 ��0/1 5�5/1 Watts ��0/1amps L H d inlet

odfsuction

odfBMg Models � fins Per inch

BMG190 19,000 4,700 8.0 3.6 2.0 0.75 950 4.1 67-3/10 25 22-7/8 1-1/8 1-1/8 175BMG260 26,000 4,500 8.0 3.6 2.0 0.75 950 4.1 67-3/10 25 22-7/8 1-1/8 1-3/8 190BMG310 31,000 7,050 12.0 5.4 3.0 1.5 1,350 5.9 95-3/10 25 22-7/8 1-3/8 1-3/8 210BMG390 39,000 6,750 12.0 5.4 3.0 1.5 1,350 5.9 95-3/10 25 22-7/8 1-3/8 1-3/8 237BMG430 43,000 8,800 16.0 7.2 4.0 2.25 1,800 7.8 123-3/10 25 22-7/8 1-3/8 1-5/8 267BMG520 52,000 8,400 16.0 7.2 4.0 2.25 1,800 7.8 123-3/10 25 22-7/8 1-3/8 1-5/8 300

BMf Models � fins Per inchBMF165 16,500 4,900 8.0 3.6 2.0 0.75 950 4.1 67-3/10 25 22-7/8 1-1/8 1-1/8 173BMF220 22,000 4,650 8.0 3.6 2.0 0.75 950 4.1 67-3/10 25 22-7/8 1-1/8 1-3/8 188BMF250 25,000 7,350 12.0 5.4 3.0 1.5 1,350 5.9 95-3/10 25 22-7/8 1-3/8 1-3/8 207BMF330 33,000 6,975 12.0 5.4 3.0 1.5 1,350 5.9 95-3/10 25 22-7/8 1-3/8 1-3/8 234BMF370 37,000 9,100 16.0 7.2 4.0 2.25 1,800 7.8 123-3/10 25 22-7/8 1-3/8 1-5/8 262BMF440 44,000 8,700 16.0 7.2 4.0 2.25 1,800 7.8 123-3/10 25 22-7/8 1-3/8 1-5/8 295

Page 16: Catalogo

1�

High Profile air defrost unit coolersModel BHa large air defrost unit coolers are ideal for warehouse cooler applications. With a wide capacity range and the patented thermo-flex™ coil design, these large unit coolers provide efficient, reliable operation. Features include a mill finish aluminum cabinet, 850 RPM motors for low noise and reliability, liquid line solenoid wiring harness for faster installation, Schrader fitting for easier suction temperature measurement. Also, the large unit coolers have captive fasteners on access panels for easy servicing — no fumbling with loose bolts and nuts. The BH Series also has a standardized terminal board for easier field wiring.

Options include totally enclosed motors, long air throw collars for large warehouse/industrial applications and insulated drain pans. PSC motors come standard to help you save energy.

Warehouse evaporators

* These models are 8 fins per inch; all other models are 6 fins per inchTD = Room Temperature - Saturated Suction Temperature

BHaModel

BtuH10°ftd

cfM

Motor total fLa dimensions(in.)

connections(in.) approx.

net Wt.(lbs.)Qty.

�08-��0�08-

��0/�

��0/1��0/� 5�5/� L H d

coil inletodf

suctionodf

ext.equal.

odf

drainfPt

Wired1 ph.

Wired� ph.

Wired1 ph.

Wired� ph.

BHA520 52,000 9,000 2 6.4 - 5.2 3.4 - 2.6 1.8 83-3/32 37-3/16 26-1/4 1-1/8 1-5/8 1/4 1-1/4 270BHA630 63,000 9,000 2 6.4 - 5.2 3.4 - 2.6 1.8 83-3/32 37-3/16 26-1/4 1-1/8 1-5/8 1/4 1-1/4 300BHA750 75,000 12,600 3 9.6 5.5 7.8 - 3.0 3.9 2.7 105-5/32 37-3/16 26-1/4 1-3/8 2-1/8 1/4 1-1/4 390BHA850 85,000 12,600 3 9.6 5.5 7.8 - 3.0 3.9 2.7 105-5/32 37-3/16 26-1/4 1-3/8 2-1/8 1/4 1-1/4 430BHA930 93,000 16,800 4 12.8 8.7 10.4 - 4.7 5.2 3.6 135-7/32 37-3/16 26-1/4 1-3/8 2-1/8 1/4 1-1/4 515

BHA1100 110,000 16,800 4 12.8 8.7 10.4 - 4.7 5.2 3.6 135-7/32 37-3/16 26-1/4 1-3/8 2-1/8 1/4 1-1/4 565BHA1170 117,000 20,700 3 - - 13.8 - - 6.9 7.8 135-13/32 44-1/2 35-21/32 1-3/8 2-1/8 1/4 1-1/4 738BHA1400 140,000 20,700 3 - - 13.8 - - 6.9 7.8 135-13/32 44-1/2 35-21/32 1-5/8 2-1/8 1/4 1-1/4 800BHA1610 161,000 24,300 3 - - 19.8 - - 9.9 7.8 135-13/32 50-7/32 35-21/32 (2) 1-3/8 (2) 2-1/8 (2) 1/4 1-1/4 850BHA1900 190,000 26,550 3 - - 21.0 - - 10.5 8.4 142-1/2 50-7/32 35-21/32 1-3/8 2-5/8 1/4 1-1/4 1,160BHA2200 220,000 30,400 4 - - 26.4 - - 13.2 10.4 185-1/2 44-1/2 35-21/32 1-3/8 2-5/8 1/4 1-1/4 1,500BHA2440 244,000 35,400 4 - - 28.0 - - 14.0 11.2 185-1/2 50-7/32 35-21/32 1-5/8 2-5/8 1/4 1-1/4 1,600BHA2160* 216,000 25,950 3 - - 21.0 - - 10.5 8.4 142-1/2 50-7/32 35-21/32 1-3/8 2-5/8 1/4 1-1/4 1,160BHA2500* 250,000 29,600 4 - - 26.4 - - 13.2 10.4 185-1/2 44-1/2 35-21/32 1-3/8 2-5/8 1/4 1-1/4 1,500BHA2780* 278,000 34,600 4 - - 28.0 - - 14.0 11.2 185-1/2 50-7/32 35-21/32 1-3/8 2-5/8 1/4 1-1/4 1,600

Page 17: Catalogo

1�

High Profile electric defrost unit coolersModels BHe/BHL large electric defrost unit coolers are ideal for warehouse freezer applications. With a wide capacity range and the patented thermo-flex™ coil design, these large unit coolers provide efficient, reliable operation. Features include a mill finish aluminum cabinet, 850 RPM motors for low noise and reliability, liquid line solenoid wiring harness for faster installation, Schrader fitting for easier suction temperature measurement. Also, the large unit coolers have captive fasteners on access panels for easy servicing — no fumbling with loose bolts and nuts. The BH Series also has a standardized terminal board for easier field wiring.

Options include high CFM motor and fan combinations, totally enclosed motors, low temp motors for blast cooling and freezing, long air throw collars for large warehouse/industrial applications and insulated drain pans. PSC motors come standard to help you save energy.

Warehouse evaporators

TD = Room Temperature - Saturated Suction TemperatureConsult Factory Representative to configure for medium temperature applications

BHe/BHLModel

BtuH10°ftd

cfM

Motor total fLa dimensions(in.)

connections(in.) approx.

net Wt.(lbs.)Qty.

�08-��0�08-

��0/�

��0/1��0/� 5�5/� L H d

coil inletodf

suctionodf

ext.equal.

odf

drainfPt

Wired1 ph.

Wired� ph.

Wired1 ph.

Wired� ph.

BHe Models � fins Per inchBHE450 45,000 9,000 2 6.4 - 5.2 3.4 - 2.6 1.8 83-3/32 37-3/16 26-1/4 1-1/8 1-5/8 1/4 1-1/4 280BHE550 55,000 9,000 2 6.4 - 5.2 3.4 - 2.6 1.8 83-3/32 37-3/16 26-1/4 1-1/8 1-5/8 1/4 1-1/4 310BHE640 64,000 12,600 3 - 5.5 7.8 - 3.0 3.9 2.7 105-5/32 37-3/16 26-1/4 1-3/8 2-1/8 1/4 1-1/4 405BHE740 74,000 12,600 3 - 5.5 7.8 - 3.0 3.9 2.7 105-5/32 37-3/16 26-1/4 1-3/8 2-1/8 1/4 1-1/4 445BHE810 81,000 16,800 4 - 8.7 10.4 - 4.7 5.2 3.6 135-7/32 37-3/16 26-1/4 1-3/8 2-1/8 1/4 1-1/4 535BHE950 95,000 16,800 4 - 8.7 10.4 - 4.7 5.2 3.6 135-7/32 37-3/16 26-1/4 1-3/8 2-1/8 1/4 1-1/4 585

BHE1020 102,000 20,700 3 - - 13.8 - - 6.9 7.8 135-13/32 44-1/2 35-21/32 1-3/8 2-1/8 1/4 1-1/4 753BHE1200 120,000 20,700 3 - - 13.8 - - 6.9 7.8 135-13/32 44-1/2 35-21/32 1-5/8 2-1/8 1/4 1-1/4 815BHE1390 139,000 24,300 3 - - 19.8 - - 9.9 7.8 135-13/32 50-7/32 35-21/32 (2) 1-3/8 (2) 2-1/8 (2) 1/4 1-1/4 865BHE1650 165,000 26,550 3 - - 21.0 - - 10.5 8.4 142-1/2 50-7/32 35-21/32 1-3/8 2-5/8 1/4 1-1/4 1,175BHE2120 212,000 35,400 4 - - 28.0 - - 14.0 11.2 185-1/2 50-7/32 35-21/32 1-5/8 2-5/8 1/4 1-1/4 1,620

BHL Models � fins Per inchBHL400 40,000 9,400 2 6.4 - 5.2 3.4 - 2.6 1.8 83-3/32 37-3/16 26-1/4 1-1/8 1-5/8 1/4 1-1/4 277BHL480 48,000 9,400 2 6.4 - 5.2 3.4 - 2.6 1.8 83-3/32 37-3/16 26-1/4 1-1/8 1-5/8 1/4 1-1/4 306BHL560 56,000 13,200 3 - 5.5 7.8 - 3.0 3.9 2.7 105-5/32 37-3/16 26-1/4 1-3/8 2-1/8 1/4 1-1/4 400BHL650 65,000 13,200 3 - 5.5 7.8 - 3.0 3.9 2.7 105-5/32 37-3/16 26-1/4 1-3/8 2-1/8 1/4 1-1/4 440BHL710 71,000 17,600 4 - 8.7 10.4 - 4.7 5.2 3.6 135-7/32 37-3/16 26-1/4 1-3/8 2-1/8 1/4 1-1/4 528BHL840 84,000 17,600 4 - 8.7 10.4 - 4.7 5.2 3.6 135-7/32 37-3/16 26-1/4 1-3/8 2-1/8 1/4 1-1/4 578BHL890 89,000 21,600 3 - - 13.8 - - 6.9 7.8 135-13/32 44-1/2 35-21/32 1-3/8 2-1/8 1/4 1-1/4 744

BHL1050 105,000 21,600 3 - - 13.8 - - 6.9 7.8 135-13/32 44-1/2 35-21/32 1-5/8 2-1/8 1/4 1-1/4 805BHL1220 122,000 25,200 3 - - 19.8 - - 9.9 7.8 135-13/32 50-7/32 35-21/32 (2) 1-3/8 (2) 2-1/8 (2) 1/4 1-1/4 854BHL1440 144,000 27,600 3 - - 21.0 - - 10.5 8.4 142-1/2 50-7/32 35-21/32 1-3/8 2-5/8 1/4 1-1/4 1,160BHL1860 186,000 36,800 4 - - 28.0 - - 14.0 11.2 185-1/2 50-7/32 35-21/32 1-5/8 2-5/8 1/4 1-1/4 1,600

Page 18: Catalogo

18

High Profile Hot gas defrost unit coolersModels BHg/BHf are large hot gas defrost unit coolers that are ideal for warehouse freezer applications. With a wide capacity range and the patented thermo-flex™ coil design, these large unit coolers provide efficient, reliable operation. Features include a mill finish aluminum cabinet, 850 RPM motors for low noise and reliability, liquid line solenoid wiring harness for faster installation, Schrader fitting for easier suction temperature measurement. Also, the large unit coolers have captive fasteners on access panels for easy servicing — no fumbling with loose bolts and nuts. The BH Series also has a standardized terminal board for easier field wiring.

Options include high CFM motor and fan combinations, totally enclosed motors, low temp motors for blast cooling and freezing, long air throw collars for large warehouse/industrial applications and insulated drain pans. Also, optional field or factory-installed hot gas kits are available. PSC motors come standard to help you save energy.

Warehouse evaporators

TD = Room Temperature - Saturated Suction TemperatureConsult Factory Representative to configure for medium temperature applications

BHg/BHfModel

BtuH10°ftd

cfM

Motor total fLa dimensions(in.)

connections(in.) approx.

net Wt.(lbs.)Qty.

�08-��0�08-

��0/�

��0/1��0/� 5�5/� L H d coil inlet

odfsuction

odf

ext.equal.odf

drainfPt

Hot gasside Port

Hot gasdrn PanRef conn

Wired1 ph.

Wired� ph.

Wired1 ph.

Wired� ph.

BHg Models � fins Per inchBHG450 45,000 9,000 2 6.4 - 5.2 3.4 - 2.6 1.8 83-3/32 37-3/16 26-1/4 1-1/8 1-5/8 1/4 1-1/4 5/8 1-1/8 280BHG550 55,000 9,000 2 6.4 - 5.2 3.4 - 2.6 1.8 83-3/32 37-3/16 26-1/4 1-1/8 1-5/8 1/4 1-1/4 5/8 1-1/8 310BHG640 64,000 12,600 3 - 5.5 7.8 - 3.0 3.9 2.7 105-5/32 37-3/16 26-1/4 1-3/8 2-1/8 1/4 1-1/4 7/8 1-1/8 405BHG740 74,000 12,600 3 - 5.5 7.8 - 3.0 3.9 2.7 105-5/32 37-3/16 26-1/4 1-3/8 2-1/8 1/4 1-1/4 7/8 1-1/8 445BHG810 81,000 16,800 4 - 8.7 10.4 - 4.7 5.2 3.6 135-7/32 37-3/16 26-1/4 1-3/8 2-1/8 1/4 1-1/4 7/8 1-1/8 535BHG950 95,000 16,800 4 - 8.7 10.4 - 4.7 5.2 3.6 135-7/32 37-3/16 26-1/4 1-3/8 2-1/8 1/4 1-1/4 7/8 1-1/8 585

BHG1020 102,000 20,700 3 - - 13.8 - - 6.9 7.8 135-13/32 44-1/2 35-21/32 1-3/8 2-1/8 1/4 1-1/4 7/8 1-3/8 753BHG1200 120,000 20,700 3 - - 13.8 - - 6.9 7.8 135-13/32 44-1/2 35-21/32 1-5/8 2-1/8 1/4 1-1/4 1-1/8 1-3/8 815BHG1390 139,000 24,300 3 - - 19.8 - - 9.9 7.8 135-13/32 50-7/32 35-21/32 (2) 1-3/8 (2) 2-1/8 (2) 1/4 1-1/4 (2) 7/8 1-3/8 865BHG1650 165,000 26,550 3 - - 21.0 - - 10.5 8.4 142-1/2 50-7/32 35-21/32 (2) 1-3/8 (2) 2-5/8 (2) 1/4 1-1/4 (2) 1-1/8 1-5/8 1,175BHG2120 212,000 35,400 4 - - 28.0 - - 14.0 11.2 185-1/2 50-7/32 35-21/32 (2) 1-3/8 (2) 2-5/8 (2) 1/4 1-1/4 (2) 1-1/8 1-5/8 1,620

BHf Models � fins Per inchBHF400 40,000 9,400 2 6.4 - 5.2 3.4 - 2.6 1.8 83-3/32 37-3/16 26-1/4 1-1/8 1-5/8 1/4 1-1/4 5/8 1-1/8 277BHF480 48,000 9,400 2 6.4 - 5.2 3.4 - 2.6 1.8 83-3/32 37-3/16 26-1/4 1-1/8 1-5/8 1/4 1-1/4 5/8 1-1/8 306BHF560 56,000 13,200 3 - 5.5 7.8 - 3.0 3.9 2.7 105-5/32 37-3/16 26-1/4 1-3/8 2-1/8 1/4 1-1/4 7/8 1-1/8 400BHF650 65,000 13,200 3 - 5.5 7.8 - 3.0 3.9 2.7 105-5/32 37-3/16 26-1/4 1-3/8 2-1/8 1/4 1-1/4 7/8 1-1/8 440BHF710 71,000 17,600 4 - 8.7 10.4 - 4.7 5.2 3.6 135-7/32 37-3/16 26-1/4 1-3/8 2-1/8 1/4 1-1/4 7/8 1-1/8 528BHF840 84,000 17,600 4 - 8.7 10.4 - 4.7 5.2 3.6 135-7/32 37-3/16 26-1/4 1-3/8 2-1/8 1/4 1-1/4 7/8 1-1/8 578BHF890 89,000 21,600 3 - - 13.8 - - 6.9 7.8 135-13/32 44-1/2 35-21/32 1-3/8 2-1/8 1/4 1-1/4 7/8 1-3/8 744

BHF1050 105,000 21,600 3 - - 13.8 - - 6.9 7.8 135-13/32 44-1/2 35-21/32 1-5/8 2-1/8 1/4 1-1/4 1-1/8 1-3/8 805BHF1220 122,000 25,200 3 - - 19.8 - - 9.9 7.8 135-13/32 50-7/32 35-21/32 (2) 1-3/8 (2) 2-1/8 (2) 1/4 1-1/4 (2) 7/8 1-3/8 854BHF1440 144,000 27,600 3 - - 21.0 - - 10.5 8.4 142-1/2 50-7/32 35-21/32 (2) 1-3/8 (2) 2-5/8 (2) 1/4 1-1/4 (2) 7/8 1-5/8 1,160BHF1860 186,000 36,800 4 - - 28.0 - - 14.0 11.2 185-1/2 50-7/32 35-21/32 (2) 1-3/8 (2) 2-5/8 (2) 1/4 1-1/4 (2) 7/8 1-5/8 1,600

Page 19: Catalogo

1�

Ripening Room control Panel features• Heavy gauge steel casing with baked enamel finish• Key locks provided for control access doors• All components factory mounted and wired• Main fused disconnect with safety interlock handle• Control circuit fuse block• Evaporator fan contactor• 460/230 volt control circuit transformer for 460

volt operation• Solid-state thermostat with 50 feet of sensor lead• LED indicator lights• Controls and lights fully visible through

inspection window(s)• Four-position, rotary-type mode selector switch,

settings include:1. Cooling with continuous fan2. Cooling with fan and compressor cycling together3. Fan only4. Heating with continuous fan

• Compatible for use with parlow recording programmer• All field wiring connections made to numbered

terminal boards• Evaporator heater contactor (optional)

other evaporatorsRipening Room unit coolerModel Ru mounts to the ceiling and is specifically designed to meet the rigid requirements of many types of ripening rooms. These units include statically and dynamically balanced AMA-rated, forward-curved centrifugal fans; a DX copper tube aluminum fin cooling coil and an optional heater section with noncorrosive heaters. The blower motor and heater are available for 208/3/60, 230/3/60 or 460/3/60 power supply. For 50 cycle components are available on special order.

RU units may be controlled by either conventional type control panels, described below, or by the combined use of the control panel and a temperature-recording programmer.

features

• Heavy gauge, galvanized steel base rails with 11/16” diameter mounting holes• Cabinet panels are die-formed galvanized steel• Heavy-gauge frames• Fan bearings are rugged, self-aligning ball bearings selected for an average service life of more than 200,000 hours• Coils have plate-type aluminum fins with full collars on expanded copper tubes• Two safety thermostats, manual and automatic reset, are provided with the optional heater section to prevent overheating• Single-speed, open drip-proof, ball bearing motors• Dependable, accurate ratings

one Piece PaneL

� fPiRu

Model

standardMBH �00 fPM connections optional cfM - Motors total

HeaterkW*

approx.ship.

Wt. (lbs.)55-�0

85% RH55-�5

�0% RH�5-�5

�0% RHinletod

suctionod

Low Velocity High VelocitycfM HP cfM HP cfM HP

RU0544 7,800 2 50.1 30.5 27.0 7/8 1-1/8 6,700 1-1/2 9,400 3 6 475RU0554 7,800 2 60.6 37.3 32.7 7/8 1-1/8 6,700 1-1/2 9,400 3 6 505RU0564 7,800 2 68.9 41.5 36.6 7/8 1-3/8 6,700 1-1/2 9,400 3 6 535RU1044 15,600 (2) 2 106.2 65.1 57.3 1-1/8 1-3/8 13,400 (2) 1-1/2 18,800 (2) 3 12 950RU1054 15,600 (2) 2 128.2 79.4 69.3 1-1/8 1-5/8 13,400 (2) 1-1/2 18,800 (2) 3 12 1,010RU1064 15,600 (2) 2 147.4 90.6 79.2 1-3/8 1-5/8 13,400 (2) 1-1/2 18,800 (2) 3 12 1,070

� fPiRu

Model

MBH 550 fPM�5-55

�0% RH50-�0

�0% RH�5-�5

�0% RHRU0546 7,800 2 38.1 34.7 32.2 7/8 1-1/8 6,700 1-1/2 9,400 3 6 485RU0556 7,800 2 46.3 41.7 38.4 7/8 1-1/8 6,700 1-1/2 9,400 3 6 515RU0566 7,800 2 50.6 46.1 42.7 7/8 1-3/8 6,700 1-1/2 9,400 3 6 545RU1046 15,600 (2) 2 81.4 73.9 68.5 1-1/8 1-3/8 13,400 (2) 1-1/2 18,800 (2) 3 12 970RU1056 15,600 (2) 2 98.7 88.7 81.4 1-1/8 1-5/8 13,400 (2) 1-1/2 18,800 (2) 3 12 1,030RU1066 15,600 (2) 2 111.4 100.0 91.9 1-3/8 1-5/8 13,400 (2) 1-1/2 18,800 (2) 3 12 1,090

* Alternative kW available - consult factory

PanelModel Voltage

evaporatorHeater

contactor1015A 208 -1013A 460 -2029A 230 Yes2023A 460 Yes

1000 Series do not have heater contactors2000 Series have heater contactors

Page 20: Catalogo

�0

Beacon ii™ Refrigeration system is Bohn’s patented, pre-assembled, factory-installed refrigeration system featuring an integrated microcomputer-based electronic control board. Beacon II™ offers:

• Complete factory installation, wiring and testing, saving time and money• Simplified field electrical connections and 24 volt wiring between condenser and

evaporator coil• Preset factory superheat allows the system to run more efficiently and reduces

future adjustments• Monitors and controls box temperature, evaporator superheat, system status

and defrost• Monitor and make system changes remotely via modem with exclusive Beacon II™

Smart II software with Beacon II™ Smart Controller• Data-logging capabilities with Smart Controller

Beacon ii™ smart controller is an optional system monitoring and programming control device. It allows for adjustments to be made at the push of a button from a conveniently mounted location. Beacon II™ Smart Controller also allows you to monitor and make changes to the refrigeration system via modem connection from anywhere in the world. One Smart Controller can program and control up to four condensing units with up to four evaporators on each system.

The patented Beacon ii™ smart defrost system available with Beacon II™ Smart Controller is uniquely designed to predict frost accumulation and initiate defrosts only when needed. It also initiates defrosts to react to operation anomalies, like product deliveries and product pull-down. Typical electric defrost systems have four defrosts per day. Using the Smart Defrost system can reduce the number of defrosts to zero, one or two per day. That’s a 75 percent reduction on average, greatly reducing the amount of energy used and operating costs.

Beacon ii™ smart ii software makes it easy to adjust and monitor one or more refrigeration systems as well as capture minute-by-minute system conditions. This Windows®-based software allows you to connect to the Beacon II™ Smart Controller from anywhere in the world to monitor the systems, make adjustments and log real-time system conditions. This data-logging capability is critical in the food-service industry.

Page 21: Catalogo

�1

Performance data

Model�0°f ambient

�5°fBox temp

�8°fBox temp

PTN024H2 2,630 2,740PTN029H2 3,170 3,290PTN040H2 4,380 4,500PTN047H2 5,150 5,480PTN063H2 6,910 7,340PTN072H2 7,890 8,330PTN099H2 10,850 11,730PTN128H2 14,030 15,010

indoor Packaged Refrigeration system

Reliability/durability• System is fully assembled at the factory

and backed by Bohn’s superior quality control

• Electronic controls provide accurate temperature control

• Liquid line filter drier (medium and large cabinet only)

• Two-year parts warranty

electrical data

Model Voltage Mca MoPd unitamps

evap.cfM

Plugsupplied

MatchingneMa

Receptacle

approx.net Wt.

(lbs./kg.)PTN024H2APTN029H2APTN040H2A

115/1/60115/1/60115/1/60

10.210.611.7

151515

8.79.09.9

340340340

YesYesYes

5-20R5-20R5-20R

889092

404142

PTN047H2APTN047H2BPTN063H2BPTN072H2B

115/1/60208-230/1/60208-230/1/60208-230/1/60

16.98.69.8

10.9

20151515

14.27.38.49.3

350350550500

YesYes Yes Yes

5-20R6-15R6-15R6-15R

192192207211

87879495

PTN099H2BPTN099H2CPTN128H2BPTN128H2C

208-230/1/60208-230/3/60208-230/1/60208-230/3/60

17.114.720.114.1

20203020

14.713.317.112.8

875875825825

Yes ---

6-20R---

270265290285

122120132129

PTN019L6A 115/1/60 13.0 20 11.0 340 Yes 5-20R 101 46PTN021L6APTN021L6BPTN031L6BPTN044L6B

115/1/60208-230/1/60208-230/1/60208-230/1/60

13.97.6

13.815.9

20151520

11.86.5

11.613.3

350350550520

YesYes Yes Yes

5-20R6-15R6-15R6-20R

213213221225

9797

100102

PTN052L6BPTN052L6CPTN069L6BPTN069L6C

208-230/1/60208-230/3/60208-230/1/60208-230/3/60

17.712.223.815.9

20153020

15.311.320.014.2

900900875875

Yes ---

6-20R---

275270280275

125122127125

Bohn brings you the simplest, most reliable solution for walk-in refrigeration systems in a single package! The PRO3 (‘pro ‘kyübd) system comes ready to mount on top of the cooler or freezer and requires minimal space. The evaporator section is outside of the box, allowing for maximum use of refrigerated space inside the box.

Model�0°f ambient

0°fBox temp

-10°fBox temp

-�0°fBox temp

PTN019L6 2,640 - -PTN021L6 2,860 2,300 1,430PTN031L6 4,500 3,400 2,200PTN044L6 6,260 4,830 3,630PTN052L6 7,470 5,720 4,170PTN069L6 9,670 7,850 5,600

ease of installation• Simple, quick installation with no piping or

loose components to install saves on labor

• Installation takes a fraction of the time required for a split system

• Evaporator grill mounts flush to or recessed in a standard 4” ceiling panel to allow for more storage in the cooler or freezer

• Models come with a condensate evaporation pan, eliminating the need for a drain line

ease of use• Most models come with a 26”

power cord ready to plug in

• System is factory assembled, evacuated, charged, run tested and wired; no additional components required

• Controls preset for typical applications, 35°F for coolers, —10°F for freezers, and are easy to adjust (019L6 set for 0°F)

freezers - electric defrost systems

coolers - air defrost systems

Page 22: Catalogo

��

Bohnmizer® system features

• Integral subcooling condenser circuit (Discus® units)• Ball bearing fan motors• Galvanized steel base• Receiver• Crankcase heater• Suction accumulator• Oil pressure safety control (size 5 HP and larger)• Corrosion resistant cabinet design• Numerous isolation valves• Fan cycling• Suction filter• Sight glass/moisture indicator• Discharge and suction vibration eliminators• Room thermostat• Solenoid valve• Liquid line filter/drier• Compressor contactor• Heat exchanger (Low Temp R-404A and R-507 only)• Defrost kit (where applicable)• Bohnmizer® expansion valve• Oil separator on -20° systems• PSC motors come standard on condensing units to help you save energy

Bohnmizer® system advantages• Automatic all-climate operation• All factory-selected components• Single-source responsibility• Longer compressor life• More capacity• Less refrigerant charge• Less operating costs• Less installation cost• Reduced maintenance costs

Bohnmizer® split systems1/� - 80 HP

Model BBVSizes 12 - 80 HP, semi-hermetic

All models have Discus® compressor for maximum efficiency

Models BHB/BsB/BZBSizes 1/2 - 6 HP

available with hermetic, semi-hermetic or Scroll® compressors

Model BBHSizes 3 - 22 HP, semi-hermetic,

Scroll® and Discus® compressors

Page 23: Catalogo

��

indoor or outdoor installation with semi-hermetic compressors (1/� - 5 HP)Model Bs condensing units are ideal for convenience store, restaurant and other commercial applications. The units feature a semi-hermetic refrigeration compressor, which is spring-mounted with vibration eliminators. Also, these condensing units have an oversized aluminum fin/copper tube condenser that works in high ambients, encapsulated auto-reset high pressure controls to eliminate leaks, pre-painted G90 galvanized steel cabinet for superior strength and corrosion protection, and suction and discharge service valves. PSC motors come standard to help you save energy. UL listed for US and Canada.

1/� - � HP air-cooled condensing units

* = T for outdoor, N for indoor, S for Beacon II™

1 Minimum Circuit Amps - Air Defrost Type Unit2 NRD1-040E compressor is single-phase and uses R-404A only3 Uses R-404A and 507 in three-phase model

BsModel compressor Refrigerant suction

temp

BtuH�5°f

ambient

connections (in.) Minimum circuit ampacity1 dimensions (in.) approx.net Wt.

(lbs.)Liquid

idssuction

ids�08-

��0/1�08-

��0/� ��0/� ��0/1 L H d

BS*005H2BS*008H2BS*008M2

HAG0050KAN0075KAE0075

Medium& HightempR-��

�5°f

4,430 6,920 7,910

3/83/83/8

1/25/85/8

151515

151515

---

---

23-3/423-3/423-3/4

17-1/417-1/417-1/4

28-1/428-1/428-1/4

170181189

BS*010H2BS*010M2BS*015H2

KAR0100KAM0100KAG0150

9,26010,69012,230

3/83/83/8

5/85/87/8

151515

151515

--

15

---

23-3/423-3/437-3/4

17-1/417-1/417-1/4

28-1/428-1/428-1/4

191191220

BS*020H2BS*020M2BS*021M2

ERA0200KAK0200ERC0200

16,21016,53017,640

3/83/83/8

7/87/87/8

-15-

151515

15-

15

15-

15

37-3/437-3/437-3/4

17-1/417-1/417-1/4

28-1/428-1/428-1/4

286224286

BS*029M2BS*030H2BS*030M2

ERF0310ERF03103RA0310

24,72026,80032,290

1/21/21/2

7/87/87/8

---

152020

151515

212324

37-3/442-1/242-1/2

19-3/429-3/429-3/4

28-1/430-1/430-1/4

318377377

BS*040H2BS*050H2BS*050M2

NRB0400NRA0500NRM0500

38,95044,69051,590

1/21/21/2

1-1/81-1/81-1/8

---

282531

151515

---

42-1/242-1/242-1/2

29-3/429-3/429-3/4

30-1/430-1/430-1/4

431431431

BS*005M6BS*010M6BS*020M6

HAJ005EKAR010EKAK020E

Mediumtemp

R-�0�a/50�

�5°f

5,210 9,75016,240

3/83/83/8

1/25/87/8

151515

-1515

---

---

23-3/423-3/437-3/4

17-1/417-1/417-1/4

28-1/428-1/428-1/4

175190224

BS*021M6BS*030M6BS*040M6

ERC021EERF031ENRB040E

20,06029,69039,240

3/81/21/2

7/87/8

1-1/8

---

152028

151515

-23-

37-3/442-1/242-1/2

17-1/429-3/429-3/4

28-1/430-1/430-1/4

293370442

BS*005L2BS*008L2

KA0050KAM0075

LowtempR-��

-10°f

2,560 4,560

3/83/8

1/25/8

1515

-15

--

--

23-3/423-3/4

17-1/417-1/4

28-1/428-1/4

181189

BS*010L2BS*020L2BS*021L2BS*030L2

KAJ0100EAD0200EAV0210LAH0310

5,630 9,58011,01015,630

3/83/83/81/2

5/87/87/87/8

15-

20-

15151515

--

1515

-15-

20

23-3/437-3/437-3/437-3/4

17-1/417-1/417-1/419-3/4

28-1/428-1/428-1/428-1/4

181281286345

BS*005L6BS*008L6BS*010L6

KAN005EKAM007EKAJ010E

Lowtemp

R-�0�a/50�

-10°f

2,580 4,320 5,790

3/83/83/8

1/25/85/8

151515

151515

---

---

23-3/423-3/423-3/4

17-1/417-1/417-1/4

28-1/428-1/428-1/4

186185192

BS*015L6BS*020L6BS*021L6

KAL015EEAD020EEAV021E

8,920 9,87011,280

3/83/83/8

7/87/87/8

15-

20

151515

15-

15

-15-

37-3/437-3/437-3/4

17-1/417-1/417-1/4

28-1/428-1/428-1/4

218286284

BS*027L6BS*030L6BS*030E6

3AB031ELAH032ELAC032E

13,21016,930

-

1/21/21/2

7/87/87/8

---

151515

152015

202020

37-3/437-3/437-3/4

19-3/419-3/419-3/4

28-1/428-1/428-1/4

331336336

BS*040L6 NRD040E2

NRD032E3 22,530 1/2 1-1/8 - 22 15 35 42-1/2 29-3/4 30-1/4 458

Bs indoor or outdoor installation, semi-Hermetic compressors (1/� - 5 HP)

Page 24: Catalogo

��

indoor or outdoor installation with Hermetic compressors (1/� - 5 HP)

Model BH condensing units feature a hermetic refrigeration compressor with oversized condenser. Also, the BH Series condensing units have a shut off valve in the discharge line of the hermetic compressor for easier compressor changes. PSC motors come standard to help you save energy. UL listed for US and Canada.

indoor or outdoor installation with scroll® compressors (� - � HP)

Model BZ features a complete line of Copeland’s Scroll® compressors. These condensing units have an oversized condenser which allows units to operate in high ambient for 35°F boxes and below. PSC motors come standard to help you save energy. UL listed for US and Canada.

1/� – � HP air-cooled condensing units

BHModel compressor Refrigerant suction

temp

BtuH�5°f

ambient

connections (in.) unit Mca1 dimensions (in.) approx.net Wt.

(lbs.)Liquid

idssuction

ids�08-

��0/1�08-

��0/� ��0/� L H d

BH*005H2BH*008H2BH*010H2

ART82C1RS64C2RS70C1

Medium& HightempR-��

�5°f

5,9608,3509,500

3/83/83/8

1/21/25/8

151515

--

15

---

23-3/423-3/423-3/4

17-1/417-1/417-1/4

28-1/428-1/428-1/4

134146145

BH*015H2BH*020H2BH*029M2

CR18KQCR24KQCR37KQ

12,91016,91023,930

3/83/81/2

5/87/87/8

1520

21.8

151515

151515

37-3/437-3/437-3/4

17-1/417-1/419-3/4

28-1/428-1/428-1/4

186188209

BH*030H2BH*040H2BH*050H2

CR37KQCR53KQ

CRN0500

28,09038,84044,050

1/21/21/2

7/81-1/81-1/8

24.33642

2023.928

151515

42-1/242-1/242-1/2

29-3/429-3/429-3/4

30-1/430-1/430-1/4

264272286

BH*005X6BH*008X6BH*009X6

RS43C2ERS55C2ERS64C2E

extendedtemp

R-�0�a/50��5°f

5,1007,5908,580

3/83/83/8

1/21/25/8

151515

---

---

23-3/423-3/423-3/4

17-1/417-1/417-1/4

28-1/428-1/428-1/4

149149152

BH*010X6BH*015X6BH*020X6

RS70C1ECS10K6ECS12K6E

9,11013,83015,740

3/83/83/8

5/85/87/8

151515

151515

---

23-3/437-3/437-3/4

17-1/417-1/417-1/4

28-1/428-1/428-1/4

146193193

BH*025X6BH*030X6BH*032X6

CS14K6ECS18K6ECS20K6E

17,19027,01029,540

3/81/21/2

7/87/87/8

152124

151520

151515

37-3/442-1/242-1/2

17-1/429-3/429-3/4

28-1/430-1/430-1/4

194271272

BH*040X6BH*050X6

CS27K6ECS33K6E

37,27042,460

1/21/2

1-1/81-1/8

30.338

20.724.5

1515

42-1/242-1/2

29-3/429-3/4

30-1/430-1/4

272276

BH*011L6BH*014L6BH*019L6

CF04K6ECF06K6ECF06K6E Low temp

R-�0�a/50� -10°f

5,2897,7908,710

3/83/83/8

5/85/85/8

151515

151515

---

23-3/423-3/437-3/4

17-1/417-1/417-1/4

28-1/428-1/428-1/4

159160200

BH*025L6BH*031L6

CF09K6ECF12K6E

13,15015,909

3/81/2

7/87/8

2022.3

1515

-15

37-3/437-3/4

17-1/419-3/4

28-1/428-1/4

209217

BZModel compressor Refrigerant suction

temp

BtuH�5°f

ambient

connections (in.) unit Mca1 dimensions (in.) approx.net Wt.

(lbs.)Liquid

idssuction

ids�08-

��0/1�08-

��0/� ��0/� L H d

BZ*020M6BZ*025M6

ZS15K4EZS19K4E

Mediumtemp

R-�0�a/50�/���

�5°f

18,93022,490

1/21/2

7/87/8

2020

1515

1515

37-3/437-3/4

19-3/419-3/4

28-1/428-1/4

194203

BZ*030M6BZ*035M6

ZS21K4EZS26K4E

27,27032,820

1/21/2

7/87/8

2227

2020

1515

42-1/242-1/2

29-3/429-3/4

30-1/430-1/4

262265

BZ*045M6BZ*055M6BZ*060M6

ZS30K4EZS38K4EZS45K4E

38,23045,16052,340

1/21/21/2

1-1/81-1/81-1/8

3440-

202830

151515

42-1/242-1/242-1/2

29-3/429-3/429-3/4

30-1/430-1/430-1/4

282291292

BZ*020L6BZ*025L6

ZF06K4EZF08K4E

Lowtemp

R-�0�a/50�/���

-10°f

9,54011,850

1/21/2

7/87/8

2020

1515

1515

37-3/437-3/4

19-3/419-3/4

28-1/428-1/4

194203

BZ*030L6BZ*035L6

ZF09K4EZF11K4E

13,20015,860

1/21/2

7/87/8

2024

1520

1515

37-3/437-3/4

19-3/419-3/4

28-1/428-1/4

197200

BZ*045L6BZ*055L6BZ*060L6

ZF13K4EZF15K4EZF18K4E

20,41024,65028,970

1/21/21/2

1-1/81-1/81-1/8

3440-

202830

151515

42-1/242-1/242-1/2

29-3/429-3/429-3/4

30-1/430-1/430-1/4

282291292

BH series indoor or outdoor installation, Hermetic compressors (1/� - 5 HP)

* = T for outdoor, N for indoor, S for Beacon II™

1 Minimum Circuit Amps - Air Defrost Type Unit

* = T for outdoor, N for indoor, S for Beacon II™

1 Minimum Circuit Amps - Air Defrost Type Unit2 For R-22 model capacity information, see product bulletin

BZ series indoor or outdoor installation, scroll® compressors (� - � HP)

Page 25: Catalogo

�5

� - �� HP air-cooled condensing unitsindoor or outdoor installation with discus® or scroll® compressors (� - �� HP)Models Bd/BZ 3-22 HP condensing unit’s enhanced grill design gives up to 40 percent more free-air area than before and its vertical receiver needs less refrigerant to ensure a solid column of liquid reaches the expansion valve. Fan motors and serviceable components are accessible through the front grill for quick service and the sight glass is conveniently placed so that charging is quick, easy and accurate. Thorough cleaning of the coil is easier because the unit’s top is one piece and lighter for easy removal. A liquid base valve and suction service tap is placed on the outside of the cabinet for easy pump-downs and quick diagnosis. The footprint is smaller for easy jobsite placement. These condensing units utilize the floating tube™ coil design that eliminates tube-sheet leaks, allowing Bohn to offer you a 5-year warranty (including labor and refrigerant) against tube-sheet leaks. This unit is also available in the low-power Bohnmizer® configuration that reduces energy costs. PSC motors come standard to help you save energy.

BdModel compressor Refrigerant suction

tempBtuH�5˚famb.

air defrostMin. circuit amp connections (in.) dimensions (in.) approx.

net Wt.(lbs.)�08-��0/

�0/���0/�0/� Liquid suction L H d

BD*0300L6BD*0400L6

2DF3F16KE2DL3F20KE

Lowtemp

R-�0�a/50�

-10ºf

25,32029,620

20.632.2

10.813.4

1/21/2

1-1/81-1/8

36-3/436-3/4

39-1/439-1/4

51-3/451-3/4

737741

BD*0600L6BD*0601L6BD*0750L6

2DB3F25KE3DA3F28KE3DB3F33KE

35,16038,92045,630

34.432.737.2

16.815.419.5

1/21/21/2

1-1/81-1/81-1/8

36-3/436-3/436-3/4

39-1/439-1/439-1/4

51-3/451-3/451-3/4

751781805

BD*0900L6BD*1000L6BD*1200L6BD*1500L6BD*2200L6

3DF3F40KE3DS3F46KE4DA3F47KE4DL3F63KE4DT3F76KE

59,28064,87070,88089,380

103,010

46.951.959.967.880.9

22.624.630.033.940.5

5/85/87/87/87/8

1-3/81-3/81-5/81-5/81-5/8

36-3/436-3/441-3/441-3/441-3/4

39-1/439-1/448-3/448-3/448-3/4

63-3/463-3/475-1/875-1/875-1/8

1,0301,0351,1991,2341,224

BD*0300L2BD*0400L2

2DF3F16KE2DL3F20KE

LowtempR-��

-10ºf

22,16025,870

20.632.2

10.813.4

1/21/2

1-1/81-1/8

36-3/436-3/4

39-1/439-1/4

51-3/451-3/4

737741

BD*0600L2BD*0601L2BD*0750L2

2DB3F25KE3DA3F28KE3DB3F33KE

31,18034,76042,060

34.432.737.2

16.815.419.5

1/21/21/2

1-1/81-1/81-1/8

36-3/436-3/436-3/4

39-1/439-1/439-1/4

51-3/451-3/451-3/4

751781805

BD*0900L2BD*1000L2BD*1200L2BD*1500L2BD*2200L2

3DF3F40KE3DS3F46KE4DA3F47KE4DL3F63KE4DT3F76KE

53,29057,23063,60079,76092,430

46.951.959.967.880.9

22.624.630.033.940.5

5/85/87/87/87/8

1-3/81-3/81-5/81-5/81-5/8

36-3/436-3/441-3/441-3/441-3/4

39-1/439-1/448-3/448-3/448-3/4

63-3/463-3/475-1/875-1/875-1/8

1,0301,0351,1991,2341,224

BD*0500M6BD*0501M6

2DC3R53KE2DD3R63KE

Mediumtemp

R-�0�a/50�

�0ºf

39,69046,000

27.727.7

13.613.7

1/21/2

1-1/81-1/8

36-3/436-3/4

39-1/439-1/4

51-3/451-3/4

751751

BD*0750M6BD*0751M6BD*0800M6

2DL3R78KE2DA3R89KE3DA3R10ME

56,36067,93080,710

38.141.351.4

17.419.626.2

1/25/85/8

1-1/81-3/81-3/8

36-3/436-3/436-3/4

39-1/439-1/439-1/4

51-3/463-3/463-3/4

761985

1,020BD*1000M6BD*1200M6BD*1500M6

3DB3R12ME3DF3R15ME3DS3R17ME

94,670111,440128,750

54.359.475.7

26.230.236.9

5/85/87/8

1-3/81-3/81-5/8

36-3/436-3/441-3/4

39-1/439-1/448-3/4

63-3/463-3/475-1/8

1,0451,0651,182

BD*0500H2BD*0501H2

2DC3R53KE2DD3R63KE

Medium& HightempR-��

�5ºf

43,38049,380

27.727.7

13.613.7

1/21/2

1-1/81-1/8

36-3/436-3/4

39-1/439-1/4

51-3/451-3/4

751751

BD*0750H2BD*0751H2BD*0800H2

2DL3R78KE2DA3R89KE3DA3R10ME

61,86071,93088,450

38.141.351.4

17.419.626.2

1/25/85/8

1-1/81-3/81-3/8

36-3/436-3/436-3/4

39-1/439-1/439-1/4

51-3/463-3/463-3/4

761985

1,020BD*1000H2BD*1200H2BD*1500H2

3DB3R12ME3DF3R15ME3DS3R17ME

103,250115,210134,780

54.359.475.7

26.230.236.9

5/85/87/8

1-3/81-3/81-5/8

36-3/436-3/441-3/4

39-1/439-1/448-3/4

63-3/463-3/475-1/8

1,0451,0651,182

BZModel compressor Refrigerant suction

tempBtuH�5˚famb.

air defrostMin. circuit amp connections (in.) dimensions (in.) approx.

net Wt.(lbs.)�08-��0/

�0/���0/�0/� Liquid suction L H d

BZ*0750L6BZ*1000L6

ZF24K4EZF33K4E

Lowtemp

R-�0�a/50�

-10ºf

32,65045,630

36.451.6

19.525.5

1/21/2

1-1/81-1/8

36-3/436-3/4

39-1/439-1/4

51-3/451-3/4

671671

BZ*1300L6BZ*1500L6

ZF40K4EZF48K4E

57,90065,370

64.767.1

33.431.0

5/85/8

1-3/81-3/8

36-3/436-3/4

39-1/439-1/4

63-3/463-3/4

910891

BZ*0750L2BZ*1000L2

ZF24K4EZF33K4E Low

tempR-��

-10ºf

30,61042,940

36.451.6

19.525.5

1/21/2

1-1/81-1/8

36-3/436-3/4

39-1/439-1/4

51-3/451-3/4

671671

BZ*1300L2BZ*1500L2

ZF40K4EZF48K4E

53,53060,860

64.767.1

33.431.0

5/85/8

1-3/81-3/8

36-3/436-3/4

39-1/439-1/4

63-3/463-3/4

910891

BZ*0650M6BZ*0700M6

ZB50KCEZB58KCE

Hightemp

R-�0�a�5ºf

56,23067,790

34.839.9

18.722.2

1/25/8

1-1/81-3/8

36-3/436-3/4

39-1/439-1/4

51-3/463-3/4

574800

BZ*0750M6BZ*0860M6

ZB66KCEZB76KCE

77,66089,080

39.151.9

23.423.4

5/85/8

1-3/81-3/8

36-3/436-3/4

39-1/439-1/4

63-3/463-3/4

813818

BZ*1000M6BZ*1400M6

ZS92K4EZS11M4E

105,030115,470

64.772.7

31.835.5

5/87/8

1-3/81-5/8

36-3/436-3/4

39-1/439-1/4

63-3/463-3/4

908915

Bd standard discus® Model

BZ scroll® Model

Page 26: Catalogo

��

Remote Water-cooled condensing units with Hermetic or scroll® compressors (1/� - � HP)

Models HW/ZW are water-cooled hermetic and Scroll® condensing units from 1/2 - 6 HP. The condensing units’ component selection, location, base and unit dimensions are all optimized for easy field replacements or in new installations where space is limited. Extra space is provided inside the electrical box for easy servicing. The area is large enough to accommodate circuit breakers, compressor contactors, time clocks and all start components in one enclosure.

Standard features include compressor isolation valves that enable services technicians to isolate the compressor for service. Also standard is the extra capacity receiver which provides total refrigerant pump-down. Ideal for units requiring long line runs. These units are available with Copeland hermetic, Scroll® low and medium temperature compressors as well as hermetic low temperature compressors for R-22 and R-404A. These units are UL listed for US and Canada.

Hermetic & scroll® Water-cooled condensing units

HWnModel compressor Refrigerant suction

temp

BtuH�5˚famb.

air defrosttotal Mca

connections (in.)ods dimensions (in.) approx.

net Wt.(lbs.)�08-��0/

�0/1�08-��0/

�0/���0/�0/� Liquid suction L H d

HWN005H2HWN008H2

ART82C1RS64C2

Medium& HightempR-��

�0°f

5,390 7,500

1515

--

--

3/83/8

1/21/2

2222

1717

1414

7792

HWN010H2HWN015H2

RS70C1CR18KQ

8,81011,240

1515

1515

-15

3/83/8

5/85/8

2227

1721

1422

92136

HWN020H2HWN030H2

CR24KQCR37KQ

14,33023,660

2021

1515

1515

3/81/2

5/87/8

2729

2128

2225

141174

HWN040H2HWN050H2

CR53KQCRN50500

33,74040,460

3339

2024

1515

1/21/2

7/87/8

2929

2828

2525

196221

HWN005X6HWN008X6

RS43C2ERS55C2E

extendedtemp

R-�0�a/50�

10°f

4,060 5,280

1515

--

--

3/83/8

1/21/2

2222

1717

1414

9898

HWN009X6HWN010X6

RS64C2ERS70C2E

6,395 6,800

1515

-15

--

3/83/8

5/85/8

2222

1717

1414

103107

HWN015X6HWN020X6

CS10K6ECS12K6E

9,71011,490

1515

1515

--

3/83/8

5/87/8

2727

2121

2222

148148

HWN025X6HWN030X6

CS14K6ECS18K6E

13,63017,400

1518

1515

1515

3/81/2

7/87/8

2727

2128

2222

152172

HWN032X6HWN040X6HWN050X6

CS20K6ECS27K6ECS33K3E

19,22023,90128,838

212735

152021

151515

1/21/21/2

7/87/87/8

272929

282828

222525

182183207

HWN011L6HWN014L6

CF04K6ECF06K6E

Lowtemp

R-�0�a/50�

-10°f

5,310 8,700

1515

1515

--

3/83/8

5/85/8

2727

2121

2222

114114

HWN025L6HWN031L6

CF09K6ECF12K6E

12,59016,060

2021

1515

-15

3/81/2

5/87/8

2727

2121

2222

120136

ZWnModel compressor Refrigerant suction

temp

BtuH�5˚famb.

air defrosttotal Mca

connections (in.)ods

dimensions(in.) approx.

net Wt.(lbs.)�08-��0/

�0/1�08-��0/

�0/���0/�0/� Liquid suction L H d

ZWN030X6ZWN035X6

ZS21K4EZS26K4E extended

tempR-�0�a

/50�

10°f

19,74024,490

18.423.2

1515.2

1515

1/21/2

7/87/8

2929

2828

2525

171186

ZWN045X6ZWN055X6

ZS30K4EZS38K4E

28,48034,970

3036

1724

1515

1/21/2

7/87/8

2929

2828

2525

207226

ZWN060X6 ZS45K4E 41,850 - 27 15 1/2 7/8 29 28 25 241ZWN030L6ZWN035L6

ZF09K4EZF11K4E Low

tempR-�0�a

/50�

-10°f

13,20016,200

1823

1515

1515

1/21/2

7/87/8

2727

2828

2222

159165

ZWN045L6ZWN055L6

ZF13K4EZF15K4E

19,10023,300

3036

1724

1515

1/21/2

7/87/8

2727

2828

2222

185201

ZWN060L6 ZF18K4E 27,700 - 27 15 1/2 7/8 29 28 25 207

HWn – Hermetic compressor Model

ZWn – scroll® compressor Model

Page 27: Catalogo

��

Water-cooled condensing units

indoor Water-cooled condensing units (�/� - �� HP)

Model sWn are “vessel-mounted” indoor water-cooled condensing units with a shell and tube. The cleanable water-cooled condenser is perfect for applications where air-cooled condensers would not be practical or water is readily available. Available in sizes 3/4 - 20 HP in all temperature ranges, the SWN units are an economical, compact selection.

sWn Model

sWnModel compressor Refrig. suction

temp

BtuH105˚fcond.

air defrosttotal Mca

connections(in.)

dimensions(in.) approx.

net Wt.(lbs.)�08-��0/

�0/1 ��0/1 �08-��0/�0/�

��0/�0/� Liquid suction L H d

SWN0150L6SWN0200L6SWN0210L6

KALA016EEADA020EEAVA021E

Lowtemp

R-�0�a-10ºf

9,03010,50012,290

15.0-

20.0

-15.0

-

15.015.015.0

15.0-

15.0

3/83/83/8

7/87/87/8

23-3/423-3/423-3/4

37-1/337-1/337-1/3

333333

195325325

SWN0310E6SWN0310L6SWN0311L6

LACA032ELAHA032E2DF3F16KE

-19,85026,570

---

20.020.028.7

15.015.020.0

15.015.015.0

1/21/21/2

1-1/81-1/81-3/8

26-3/426-3/426-3/4

36-1/336-1/336-1/3

38-1/338-1/338-1/3

325325340

SWN0400L6SWN0599L6SWN0600L6

2DL3F20KE2DA3F23KE2DB3F25KE

31,92036,44039,170

---

---

29.532.331.7

15.015.015.0

1/25/85/8

1-3/81-3/81-3/8

26-3/430-1/330-1/3

36-1/339-1/439-1/4

38-1/342-1/242-1/2

385415415

SWN0601L6SWN0750L6SWN0900L6

3DA3F28KE3DB3F33KE3DF3F40KE

43,68051,56063,210

---

---

30.034.541.5

15.020.020.0

5/85/85/8

1-3/81-5/81-5/8

30-1/335-1/335-1/3

39-1/441-1/241-1/2

42-1/255-1/255-1/2

430465560

SWN1000L6SWN1500L6SWN2200L6

3DS3F46KE4DL3F63KE4DT3F76KE

70,88095,660

115,710

---

---

46.559.074.0

20.829.537.0

7/87/87/8

1-5/82-1/82-1/8

35-1/335-1/335-1/3

41-1/241-1/241-1/2

55-1/255-1/255-1/2

715780865

SWN0090M6SWN0199M6SWN0200M6

KARA010EKAKA020EERCA021E

Mediumtemp

R-�0�a�0ºf

9,14015,12019,430

15.015.0

-

---

15.015.015.0

---

3/83/83/8

7/87/87/8

23-3/423-3/423-3/4

37-1/337-1/337-1/3

333333

180210260

SWN0310M6SWN0500M6

ERFA031E2DC3R53KE

28,09043,470

--

20.0-

15.025.0

15.015.0

1/25/8

1-1/81-3/8

26-3/430-1/3

36-1/339-1/4

38-1/342-1/2

325400

SWN0075H2SWN0075M2SWN0090H2

KAN10075KAE10075KARA010E

Medium& HightempR-��

�5ºf

6,7008,0009,370

15.015.015.0

---

15.015.015.0

---

3/83/83/8

5/85/85/8

3-3/43-3/43-3/4

37-1/337-1/337-1/3

333333

165165180

SWN0100H2SWN0150H2SWN0200H2

KAM10100KAGA0150ERA10200

10,69012,15016,090

15.015.0

-

--

15.0

15.015.015.0

15.015.015.0

3/83/83/8

7/87/87/8

3-3/43-3/43-3/4

37-1/337-1/337-1/3

333333

180195260

SWN0200M2SWN0300H2SWN0400H2

ERC10200ERF10311NRB20400

19,48028,29040,130

---

15.020.0

-

15.015.024.4

15.015.015.0

3/81/21/2

7/81-1/81-1/8

3-3/426-3/426-3/4

37-1/336-1/336-1/3

3338-1/338-1/3

260325385

SWN0499H2SWN0500H2SWN0750H2

2DC3R53KE2DD3R63KE2DL3R78KE

46,23053,81067,750

---

---

25.025.035.4

15.015.020.0

5/85/85/8

1-3/81-3/81-3/8

30-1/330-1/335-1/3

39-1/439-1/441-1/2

42-1/242-1/255-1/2

400400465

SWN0760H2SWN0761H2SWN1000H2

2DA3R89KE3DA3R10ME3DB3R12ME

76,77092,810

110,190

---

---

35.946.048.9

20.022.422.4

5/85/87/8

1-3/81-3/81-5/8

35-1/335-1/335-1/3

41-1/241-1/241-1/2

55-1/255-1/255-1/2

465465715

SWN1500H2SWN2000H2

3DS3R17ME4DA3R18ME

146,060156,830

--

--

66.965.9

29.532.9

7/87/8

1-5/81-5/8

35-1/335-1/3

41-1/241-1/2

55-1/255-1/2

735795

Page 28: Catalogo

�8

Remote compressor units

Remote indoor compressor condensing units (�/� - �� HP)

Model sRn indoor compressor unit is designed for use with a remote air-cooled or evaporative condenser. Typical applications include supermarkets, warehouses, convenience stores or wherever outdoor roof or pad space is at a minimum. SRN units are available in sizes 3/4 - 22 HP in high, medium and low temperature.

sRn Model

sRnModel compressor Refrig. suction

temp

BtuH�5˚famb.

air defrosttotal Mca

connections(in.)

dimensions(in.) approx.

net Wt.(lbs.)�08-��0/

�0/1 ��0/1 �08-��0/�0/�

��0/�0/� Liquid suction L H d

SRN0150L6SRN0200L6SRN0210L6

KALA016EEADA020EEAVA021E

Lowtemp

R-�0�a-10ºf

8,4809,960

11,550

15.0-

20.0

-15.0

-

15.015.015.0

15.0-

15.0

3/83/83/8

7/87/87/8

23-3/423-3/423-3/4

36-1/336-1/336-1/3

353535

175305305

SRN0310E6SRN0310L6SRN0311L6

LACA032ELAHA032E2DF3F16KE

-18,66025,330

---

20.020.028.7

15.015.020.0

15.015.015.0

1/21/21/2

1-1/81-1/81-3/8

26-3/426-3/426-3/4

39-1/439-1/439-1/4

404040

305305320

SRN0400L6SRN0599L6SRN0600L6

2DL3F20KE2DA3F23KE2DB3F25KE

30,53034,87037,520

---

---

29.532.331.7

15.015.015.0

1/25/85/8

1-3/81-3/81-3/8

26-3/430-1/330-1/3

39-1/439-1/439-1/4

4042-1/242-1/2

360390390

SRN0601L6SRN0750L6SRN0900L6

3DA3F28KE3DB3F33KE3DF3F40KE

42,08049,71060,950

---

---

30.034.541.5

15.020.020.0

5/85/85/8

1-3/81-5/81-5/8

30-1/335-1/335-1/3

39-1/443-1/243-1/2

42-1/24747

405385520

SRN1000L6SRN1500L6SRN2200L6

3DS3F46KE4DL3F63KE4DT3F76KE

68,26092,330

110,880

---

---

46.559.074.0

20.829.537.0

7/87/87/8

1-5/82-1/82-1/8

35-1/335-1/335-1/3

43-1/243-1/243-1/2

474747

650710725

SRN0090M6SRN0199M6SRN0200M6

KARA010EKAKA020EERCA021E

Mediumtemp

R-�0�a�0ºf

7,78012,85016,310

15.015.0

-

---

15.015.015.0

---

3/83/83/8

7/87/87/8

23-3/423-3/423-3/4

36-1/336-1/336-1/3

353535

155200245

SRN0310M6SRN0500M6

ERFA031E2DC3R53KE

24,08037,370

--

20.0-

15.025.0

15.015.0

1/25/8

1-1/81-3/8

26-3/430-1/3

39-1/439-1/4

4042-1/2

305375

SRN0075H2SRN0075M2SRN0090H2

KAN10075KAE10075KARA010E

Medium& HightempR-��

�5ºf

5,9707,1108,360

15.015.015.0

---

15.015.015.0

---

3/83/83/8

5/85/85/8

23-3/423-3/423-3/4

36-1/336-1/336-1/3

353535

155155160

SRN0100H2SRN0150H2SRN0200H2

KAM10100KAGA0150ERA10200

9,58010,92013,100

15.015.0

-

--

15.0

15.015.015.0

15.015.015.0

3/83/83/8

7/87/87/8

23-3/423-3/423-3/4

36-1/336-1/336-1/3

353535

160175245

SRN0200M2SRN0300H2SRN0400H2

ERC10200ERF10311NRB20400

17,26025,58035,260

---

15.020.0

-

15.015.024.4

15.015.015.0

3/81/21/2

7/81-1/81-1/8

23-3/426-3/426-3/4

36-1/339-1/439-1/4

354040

245305360

SRN0499H2SRN0500H2SRN0750H2

2DC3R53KE2DD3R63KE2DL3R78KE

41,29048,32061,380

---

---

25.025.035.4

15.015.020.0

5/85/85/8

1-3/81-3/81-3/8

30-1/330-1/335-1/3

39-1/439-1/443-1/2

42-1/242-1/2

47

375375385

SRN0760H2SRN0761H2SRN1000H2

2DA3R89KE3DA3R10ME3DB3R12ME

69,68084,740

101,120

---

---

35.946.048.9

20.022.422.4

5/85/87/8

1-3/81-3/81-5/8

35-1/335-1/335-1/3

43-1/243-1/243-1/2

474747

385385595

SRN1500H2SRN2000H2

3DS3R17ME4DA3R18ME

134,160143,520

--

--

66.965.9

29.532.9

7/87/8

1-5/81-5/8

35-1/335-1/3

43-1/243-1/2

4747

615375

Page 29: Catalogo

��

1� - �0 HP air-cooled condensing unitsModels BBV/BLV condensing units are designed to meet the needs of a demanding commercial and industrial refrigeration market. The product is configured to be flexible in its design and construction to allow it to respond to the requirements of refrigeration contractors, consulting engineers and facility owners/operators. The floating tube™ coil design incorporated in the product provides reliability against tube sheet leaks.

Product features

• Highly customizable for your needs as well as for fast lead times• Configurable with patented Bohnmizer® energy-saving head pressure control system,

with a Limitizer® flooding system or with no head pressure valve• Constructed from rugged pre-painted, galvanized steel for durability and aesthetics• All serviceable controls are located in a separate electrical compartment from the

main electrical box; no need to disconnect the power supply• The utilization of efficient, POE oil-charged, Discus® compressors provides efficient

operation with R-404A/507 or R-22 refrigerants• PSC motors come standard to help you save energy

air-cooled condensing units

BBV/BLVModel compressor Refriger-

antsuction

temp

BtuH�5˚famb.

air defrostMin. circuit amp

connections(in.)

net dimensions(in.)

approx.net Wt.

(lbs.)Liquid suction L H d��0/�0/� ��0/�0/�B*V1500H2B*V2000H2B*V2500H2B*V2600H2B*V3000H2B*V3500H2B*V3505H2B*V4000H2

3DS3R17ME4DA3R18ME4DH3R22ME4DH3R22ME4DJ3R28ME6DH3R35ME6DG3R37ME6DJ3R40ME

HightempR-��

�5ºf

133,500139,900182,900186,800219,900281,600295,000326,300

74.982.7

100.1106.1119.4141.2161.2179.7

36.541.350.153.159.770.680.689.8

7/87/8

1-1/81-1/81-1/81-1/81-1/81-1/8

1-5/81-5/82-1/82-1/82-1/82-1/82-1/82-1/8

144144144171171226226226

5656565656565656

4545454545454545

1,5801,5801,6301,7701,8602,2602,2602,360

B*V1500M6B*V2000M6B*V2500M6B*V2600M6B*V3000M6B*V3500M6B*V4000M6

3DS3R17ME4DA3R18ME4DH3R22ME4DH3R22ME4DJ3R28ME6DH3R35ME6DJ3R40ME

Mediumtemp

R-�0�a/50�

�5ºf

141,400147,800185,400190,800229,900292,600338,600

74.982.7

100.1106.1119.4141.2179.7

36.541.350.153.159.770.689.8

7/87/8

1-1/81-1/81-1/81-1/81-1/8

1-5/81-5/82-1/82-1/82-1/82-1/82-1/8

144144144171171226226

56565656565656

45454545454545

1,5801,5801,6301,7701,8602,2602,360

B*V1501H6B*V2001H6B*V2501H6B*V3001H6B*V3501H6B*V4001H6

3DS3R17ME4DA3R18ME4DH3R22ME4DJ3R28ME6DH3R35ME6DJ3R40ME

Hightemp

R-�0�a/50�

High eff.

�5ºf

149,600159,600201,000243,000307,900353,000

80.988.7

113.1126.4148.2186.7

39.544.356.663.274.193.3

7/87/8

1-1/81-1/81-1/81-1/8

1-5/81-5/82-1/82-1/82-1/82-1/8

171171226226281281

565656565656

454545454545

1,6801,7601,7502,1602,7702,870

B*V1500C6B*V2000C6B*V2500C6B*V2600C6B*V3000C6B*V3500C6B*V4000C6

3DS3R17ME4DA318ME

4DH3R22ME4DH3R22ME4DJ3R28ME6DH3R35ME6DJ3R40ME

comm.temp

R-�0�a/50�

10ºf

109,200111,700141,000146,500175,500223,900261,100

74.982.7

100.1106.1119.4141.2179.7

36.541.350.153.159.770.689.8

7/87/8

1-1/81-1/81-1/81-1/81-1/8

1-5/81-5/82-1/82-1/82-1/82-1/82-1/8

144144144171171226226

56565656565656

45454545454545

1,5801,5801,6301,7701,8602,2602,360

B*V1501C6B*V2001C6B*V2501C6B*V3001C6B*V3501C6B*V4001C6

3DS3R17ME4DA3R18ME4DH3R22ME4DJ3R28ME6DH3R35ME6DJ3R40ME

comm.temp

R-�0�a/50�

High eff.

10ºf

114,000119,200151,100183,500233,800270,000

80.988.7

113.1126.4148.2186.7

39.544.356.663.274.193.3

7/87/8

1-1/81-1/81-1/81-1/8

1-5/81-5/82-1/82-1/82-1/82-1/8

171171226226281281

565656565656

454545454545

1,6801,7601,7502,1602,7702,870

B*V1200L6B*V1500L6B*V2200L6B*V2700L6B*V3000L6

4DA3R12ME4DL3F63KE4DT3F76KE6DL3F93KE6DT3F11ME

Lowtemp

R-�0�a/50�

-10ºf

69,50088,100

104,300130,900147,200

59.167.080.198.5

121.2

29.633.540.149.360.2

7/87/87/8

1-1/81-1/8

1-5/81-5/82-1/82-1/82-1/8

144144144144171

5656565656

4545454545

1,5001,5001,5001,6701,870

B*V1201L6B*V1501L6B*V2201L6B*V2701L6B*V3001L6

4DA3R12ME4DL3F63KE4DT3F76KE6DL3F93KE6DT3F11ME

Lowtemp

R-�0�a/50�

High eff.

-10ºf

71,80091,100

108,200137,800152,400

59.167.080.1

104.5121.2

29.633.540.149.360.6

7/87/87/8

1-1/81-1/8

1-5/81-5/82-1/82-1/82-1/8

144144144171171

5656565656

4545454545

1,6001,7501,7801,9702,070

BBV/BLV Models

Page 30: Catalogo

�0

dual-compressor outdoor condensing units (��–80 HP)Models JBd/JLd condensing units are designed for use in commercial refrigerated warehouse and light industrial applications. The units utilize the floating tube™ coil design, offering reliabilty against tube sheet and center support leaks. The JBD/JLD consists of two independent refrigeration circuits in a single housing, which can reduce space requirements as well as installation and rigging costs. Standard models are available in even horsepower configurations from 24 to 80 horsepower; however, unequal horsepower and other customer features can be designed to suit the application.

design features

• Configurable with Bohnmizer® or Limitizer® head pressure control systems

• Generous amount of clearance under the condenser section of the unit allows for ease of service

• Highly customizable to meet you needs• All common serviceable controls are located in a separate electrical compartment from the

main electrical box; no need to disconnect power supply• Parallel piped models are also available preconfigured with additional standard features• PSC motors come standard to help you save energy

dual-compressor outdoor condensing units

J*dModel compressor Refrigerant suction

temp

BtuH�5°famb.

air defrostMin. circuit amp*

connections(in.)

dimensions(in.)

approx.net Wt.

(lbs.)��0/�0/� ��0/�0/� Liquid suction L H dJ*D3000H2J*D4000H2J*D5000H2J*D5200H2J*D6000H2J*D7000H2J*D7010H2J*D8000H2

3DS3R17ME4DA3R18ME4DH3R22ME4DH3R22ME4DJ3R28ME6DH3R35ME6DG3R37ME6DJ3R40ME

HightempR-��

�5°f

267,000279,800365,800373,600439,800563,200590,800652,600

136.4150.4181.9193.9217.8258.3294.4327.6

66.675.290.996.9

108.9129.2147.2163.8

7/87/8

1-1/81-1/81-1/81-1/81-1/81-1/8

1-5/81-5/82-1/82-1/82-1/82-1/82-1/82-1/8

144144144171171226226226

5656565656565656

8787878787878787

3,1603,1603,2303,5203,7204,3204,3204,760

J*D3000M6J*D4000M6J*D5000M6J*D5200M6J*D6000M6J*D7000M6J*D8000M6

3DS3R17ME4DA3R18ME4DH3R22ME4DH3R22ME4DJ3R28ME6DH3R35ME6DJ3R40ME

Mediumtemp

R-�0�a/50�

�5°f

282,800295,600370,800381,600459,800585,200677,200

136.4150.4181.9193.9217.8258.3327.6

66.675.290.996.9

108.9129.2163.8

7/87/8

1-1/81-1/81-1/81-1/81-1/8

1-5/81-5/82-1/82-1/82-1/82-1/82-1/8

144144144171171226226

56565656565656

87878787878787

3,1603,1603,2303,5203,7204,3204,760

J*D3000C6J*D4000C6J*D5000C6J*D5200C6J*D6000C6J*D7000C6J*D8000C6

3DS3R17ME4DA3R18ME4DH3R22ME4DH3R22ME4DJ3R28ME6DH3R35ME6DJ3R40ME

commercialtemp

R-�0�a/50�

10°f

218,400223,400282,000293,000351,000447,800522,200

136.4150.4181.9193.9217.8258.3327.6

66.675.290.996.9

108.9129.2163.8

7/87/8

1-1/81-1/81-1/81-1/81-1/8

1-5/81-5/82-1/82-1/82-1/82-1/82-1/8

144144144171171226226

56565656565656

87878787878787

3,1603,1603,2304,1403,7204,3204,760

J*D2400L6J*D3000L6J*D4400L6J*D5400L6J*D6000L6

4DA3F47KE4DL3F63KE4DT3F76KE6DL3F93KE6DT3F11ME

Lowtemp

R-�0�a/50�

-10°f

139,000176,200208,600261,800294,400

108.0122.2145.8179.0221.0

54.061.172.989.5

110.5

7/87/87/8

1-1/81-1/8

1-5/81-5/82-1/82-1/82-1/8

144144144144171

5656565656

8787878787

3,0003,0003,0003,3403,770

J*D2400L6J*D3000L6J*D4400L6J*D5400L6J*D6000L6

4DA3F47KE4DL3F63KE4DT3F76KE6DL3F93KE6DT3F11ME

LowtempR-��

-10°f

125,000158,400187,800232,200277,000

108.0122.2145.8179.0221.0

54.061.172.989.5

110.5

7/87/87/8

1-1/81-1/8

1-5/81-5/82-1/82-1/82-1/8

144144144144171

5656565656

8787878787

3,0003,0003,0003,3403,770

* MCA based on remote loads and one contactor

JBd/JLd Models

Page 31: Catalogo

�1

direct-drive air-cooled condensers

Model dVt direct-drive air-cooled condensers are the industry standard for remote air-cooled applications. Key DVT benefits such as versatility, simplicity of design and easy serviceability are the most recognized.

• Fully baffled fan sections to provide structural strength and prevent fan windmilling in the off cycle

• Multicircuiting at no extra cost

• Optional coils, including BohnGuard®, baked epoxy coating and all copper for corrosive or damaging atmospheres

• Weatherproof junction box, with motor leads terminating for single-point field wiring

• Available in either vertical or horizontal arrangement

• Optional Limitizer® system, fan cycling or variable-speed fan cycling for head pressure control

• PVC coated steel fan guards

• PSC motors come standard to help you save energy

air-cooled condensers

Model dVt

dVtModel†

condenser capacity MBH(R-��)* fan dimensions

(in.)connections

(in.) approx.net Wt.

(lbs.)tHR

�0°f tdtHR/circ.

1°f tdtube circ.available

Qty. HPfLa

��0VL W H inlet outlet

DVT001 22.9 0.76 1 1 1/4 2.0 37-1/2 22 22 3/8 3/8 96DVT002 30.5 0.51 2 1 1/4 2.0 37-1/2 22 22 5/8 5/8 96DVT003 47.1 0.52 3 1 1/4 2.0 37-1/2 22 22 7/8 5/8 114DVT005 73.0 0.30 8 1 1/3 3.4 39-3/4 43 40-1/2 11/8 7/8 180DVT008 120.0 0.25 16 1 1/2 3.9 49-3/4 43 40-1/2 11/8 7/8 260DVT010 146.0 0.30 16 2 1/3 6.8 69-3/4 43 40-1/2 (2) 11/8 (2) 7/8 450DVT012 182.4 0.38 16 2 1/2 7.8 69-3/4 43 40-1/2 (2) 11/8 (2) 7/8 470DVT014 209.6 0.44 16 2 1/2 7.8 89-3/4 43 40-1/2 (2) 11/8 (2) 7/8 510DVT016 239.6 0.25 32 2 1/2 7.8 89-3/4 43 40-1/2 (2) 13/8 (2) 11/8 530DVT021 314.2 0.44 24 3 1/2 11.7 129-3/4 43 40-1/2 (2) 15/8 (2) 11/8 550DVT023 339.6 0.47 24 3 1/2 11.7 129-3/4 43 40-1/2 (2) 15/8 (2) 11/8 580DVT026 398.2 0.41 32 3 1/2 11.7 129-3/4 43 40-1/2 (2) 15/8 (2) 11/8 625

* For R-404A and R-507, multiply MBH by 0.98† DVT models can be applied in horizontal air flow applications

Page 32: Catalogo

��

Models Bne, BnQ, BnX, BnL and BnH air-cooled condensers

Monarch™ and ambassador™ series air-cooled condensers feature improved energy efficiency and low sound levels, which are key features sought by the supermarket and grocery industry. Traditional condensers using 1140 RPM motors offer high capacities, but cannot meet the low sound and energy efficiency standards demanded today by this industry. Now, Bohn brings the best of both worlds together with advanced solutions that offer high capacities for operation, while meeting the low sound and energy efficiency requirements you demand.

Model Bne with EC motor technology offers all the benefits of variable speed motors without the complexity. EC motors utilize variable-speed technology, which optimizes fan speeds for load requirements, maximizes energy efficiency and minimizes sound.

Models BnQ, BnX and BnL features Bohn’s patented QuietEdge™ technology that uses specially designed swept fan blades to reduce noise levels. These blades are uniquely designed for each motor speed, optimizing performance and ensuring you’re receiving the lowest sound levels possible. Look for the QuietEdge™ 4 blade on the 540 RPM motors and the QuietEdge™ 5 on the 830 RPM motors.

Model BnH continues to offer Bohn’s 1140 RPM series for customers seeking the most economical solution for their capacity requirements.

air-cooled condensers

Monarch™ series Model Bne, �.� kW, �1.5” fan diameter

BneModel

tHR, MBH/1°f tdcfM

total fLaconnections

(in.)

Refrigerantsummer charge

R-�� (lbs.)

approx.net Wt.

(lbs.)R-�� R-�0�a��0

/�/�0��0

/�/�0single Row

BNES01A008 �.� �.� 11,000 7.0 3.5 1-3/8 8 330BNES01A009 �.� �.1 10,500 7.0 3.5 1-3/8 10 360BNES02A011 11.� 11.1 23,400 14.0 7.0 1-3/8 10 590BNES02A015 15.� 15.1 22,000 14.0 7.0 1-5/8 15 640BNES02A018 18.1 1�.8 20,900 14.0 7.0 2-1/8 29 690BNES03A023 ��.1 ��.� 33,100 21.0 10.5 2-1/8 22 930BNES03A027 ��.� ��.� 31,400 21.0 10.5 2-1/8 30 1,010BNES04A031 �0.8 �0.� 42,600 28.0 14.0 2-1/8 51 1,220BNES04A036 ��.� �5.5 40,000 28.0 14.0 2-5/8 70 1,320BNES05A039 ��.� �8.5 53,200 35.0 17.5 2-5/8 64 1,520BNES05A047 ��.� �5.� 50,000 35.0 17.5 2-5/8 86 1,650BNES06A056 5�.0 5�.8 60,000 42.0 21.0 2-5/8 102 1,960BNES07A065 ��.� ��.� 70,000 49.0 24.5 (2) 2-5/8 118 2,260

double RowBNED04A023 ��.� ��.� 46,700 28.0 14.0 (2) 1-3/8 19 1,290BNED04A031 �0.8 �0.� 44,100 28.0 14.0 (2) 1-5/8 29 1,390BNED04A036 ��.� ��.5 41,800 28.0 14.0 (2) 2-1/8 40 1,490BNED06A046 ��.� �5.� 66,100 42.0 21.0 (2) 2-1/8 44 2,060BNED06A054 5�.� 5�.� 62,700 42.0 21.0 (2) 2-1/8 58 2,210BNED08A062 �1.� �0.5 85,100 56.0 28.0 (2) 2-1/8 104 2,730BNED08A073 ��.5 �1.1 80,000 56.0 28.0 (2) 2-5/8 140 2,930BNED10A079 �8.� ��.0 106,400 70.0 35.0 (2) 2-5/8 125 3,410BNED10A093 ��.� �1.� 100,100 70.0 35.0 (2) 2-5/8 172 3,660BNED12A112 111.� 10�.� 120,100 84.0 42.0 (2) 2-5/8 201 4,370BNED14A129 1��.� 1��.� 140,100 98.0 49.0 (4) 2-5/8 236 5,070

Bold indicates standard model capacity at 10 FPI

Monarch™ series

ambassador™ series

Page 33: Catalogo

��

ambassador™ series Model BnQ, 5�0 RPM, 0.5 HP, �0” fan diameter

BnQModel

tHR, MBH/1°f tdcfM

total fLaconnections

(in.)

Refrigerantsummer charge

R-�� (lbs.)

approx.net Wt.

(lbs.)R-�� R-�0�a��0

/�/�0��0

/�/�0single Row

BNQS01A005 5.� 5.1 5,400 3.5 1.8 1-3/8 8 330BNQS01A006 �.1 5.� 5,200 3.5 1.8 1-3/8 10 360BNQS02A008 8.0 �.8 11,200 7.0 3.5 1-3/8 10 580BNQS02A010 10.� 10.1 10,800 7.0 3.5 1-5/8 15 630BNQS02A011 11.5 11.� 10,400 7.0 3.5 2-1/8 29 680BNQS03A016 15.� 15.� 16,100 10.5 5.3 2-1/8 22 930BNQS03A017 1�.� 1�.� 15,600 10.5 5.3 2-1/8 30 1,000BNQS04A021 �0.� �0.� 21,500 14.0 7.0 2-1/8 51 1,210BNQS04A023 ��.� ��.� 20,800 14.0 7.0 2-5/8 70 1,310BNQS05A026 �5.� �5.� 26,900 17.5 8.8 2-5/8 64 1,510BNQS05A029 �8.� �8.1 26,000 17.5 8.8 2-5/8 86 1,640BNQS06A034 ��.� ��.� 31,200 21.0 10.5 2-5/8 102 1,950BNQS07A042 �1.� �0.� 36,400 24.5 12.3 (2) 2-5/8 118 2,240

double RowBNQD04A016 1�.0 15.� 22,300 14.0 7.0 (2) 1-3/8 19 1,240BNQD04A021 �0.� �0.� 21,500 14.0 7.0 (2) 1-5/8 29 1,340BNQD04A023 ��.� ��.� 20,800 14.0 7.0 (2) 2-1/8 40 1,440BNQD06A031 �1.0 �0.� 32,300 21.0 10.5 (2) 2-1/8 44 1,990BNQD06A034 ��.� ��.� 31,200 21.0 10.5 (2) 2-1/8 58 2,140BNQD08A041 �1.� �0.� 43,000 28.0 14.0 (2) 2-1/8 104 2,630BNQD08A046 �5.8 ��.� 41,600 28.0 14.0 (2) 2-5/8 140 2,830BNQD10A052 51.8 50.� 53,700 35.0 17.5 (2) 2-5/8 125 3,290BNQD10A057 5�.� 5�.1 52,100 35.0 17.5 (2) 2-5/8 172 3,540BNQD12A069 �8.� ��.� 62,500 42.0 21.0 (2) 2-5/8 201 4,230BNQD14A083 8�.1 81.5 72,900 49.0 24.5 (4) 2-5/8 236 4,910

ambassador™ series Model BnX, 8�0 RPM, 1.0 HP, �0” fan diameter

BnXModel

tHR, MBH/1°f tdcfM

total fLaconnections

(in.)

Refrigerantsummer charge

R-�� (lbs.)

approx.net Wt.

(lbs.)R-�� R-�0�a��0

/�/�0��0

/�/�0single Row

BNXS01A006 �.� �.� 7,600 4.8 2.4 1-3/8 8 330BNXS01A008 �.5 �.� 7,300 4.8 2.4 1-3/8 10 360BNXS02A010 �.8 �.� 15,900 9.6 4.8 1-3/8 10 580BNXS02A013 1�.1 1�.8 15,200 9.6 4.8 1-5/8 15 630BNXS02A015 15.1 1�.8 14,700 9.6 4.8 2-1/8 29 680BNXS03A020 1�.� 1�.� 22,900 14.4 7.2 2-1/8 22 930BNXS03A023 ��.� ��.� 22,000 14.4 7.2 2-1/8 30 1,000BNXS04A026 ��.� �5.� 29,800 19.2 9.6 2-1/8 51 1,210BNXS04A030 �0.� ��.� 28,400 19.2 9.6 2-5/8 70 1,310BNXS05A033 ��.8 ��.1 37,300 24.0 12.0 2-5/8 64 1,510BNXS05A038 ��.8 ��.1 35,500 24.0 12.0 2-5/8 86 1,640BNXS06A045 �5.� ��.5 42,600 28.8 14.4 2-5/8 102 1,950BNXS07A052 5�.0 51.0 49,700 33.6 16.8 (2) 2-5/8 118 2,240

double RowBNXD04A020 1�.� 1�.� 31,700 19.2 9.6 (2) 1-3/8 19 1,240BNXD04A026 ��.� �5.� 30,500 19.2 9.6 (2) 1-5/8 29 1,340BNXD04A030 �0.� ��.� 29,300 19.2 9.6 (2) 2-1/8 40 1,440BNXD06A039 ��.� �8.� 45,700 28.8 14.4 (2) 2-1/8 44 1,990BNXD06A045 �5.� ��.5 44,000 28.8 14.4 (2) 2-1/8 58 2,140BNXD08A052 5�.5 51.� 59,700 38.4 19.2 (2) 2-1/8 104 2,630BNXD08A061 �0.� 5�.� 56,800 38.4 19.2 (2) 2-5/8 140 2,830BNXD10A066 �5.� ��.� 74,600 48.0 24.0 (2) 2-5/8 125 3,290BNXD10A076 �5.� ��.� 71,000 48.0 24.0 (2) 2-5/8 172 3,540BNXD12A091 �0.8 8�.0 85,200 57.6 28.8 (2) 2-5/8 201 4,230BNXD14A104 10�.1 10�.0 99,400 67.2 33.6 (4) 2-5/8 236 4,910

air-cooled condensers

Bold indicates standard model capacity at 10 FPI

Bold indicates standard model capacity at 10 FPI

Page 34: Catalogo

��

ambassador™ series Model BnL, 8�0 RPM, 1.5 HP, �0” fan diameter

BnLModel

tHR, MBH/1°f tdcfM

total fLaconnections

(in.)

Refrigerantsummer charge

R-�� (lbs.)

approx.net Wt.

(lbs.)R-�� R-�0�a��0

/�/�0��0

/�/�05�5

/�/�0single Row

BNLS01A007 �.� �.� 8,400 6.6 3.3 2.6 1-3/8 8 330BNLS01A008 8.0 �.8 8,000 6.6 3.3 2.6 1-3/8 10 360BNLS02A010 10.1 �.� 17,500 13.2 6.6 5.2 1-3/8 10 580BNLS02A014 1�.� 1�.� 16,700 13.2 6.6 5.2 1-5/8 15 630BNLS02A016 1�.1 15.8 16,100 13.2 6.6 5.2 2-1/8 29 680BNLS03A021 �0.� �0.5 25,100 19.8 9.9 7.8 2-1/8 22 930BNLS03A024 ��.� ��.8 24,100 19.8 9.9 7.8 2-1/8 30 1,000BNLS04A028 ��.8 ��.� 32,800 26.4 13.2 10.4 2-1/8 51 1,210BNLS04A032 ��.� �1.� 31,200 26.4 13.2 10.4 2-5/8 70 1,310BNLS05A035 �5.5 ��.� 41,000 33.0 16.5 13.0 2-5/8 64 1,510BNLS05A042 �1.� �0.8 39,100 33.0 16.5 13.0 2-5/8 86 1,640BNLS06A050 ��.� �8.� 46,900 39.6 19.8 15.6 2-5/8 102 1,950BNLS07A055 55.0 5�.� 54,700 46.2 23.1 18.2 (2) 2-5/8 118 2,240

double RowBNLD04A020 �0.� 1�.8 35,000 26.4 13.2 10.4 (2) 1-3/8 19 1,240BNLD04A028 ��.8 ��.� 33,500 26.4 13.2 10.4 (2) 1-5/8 29 1,340BNLD04A032 ��.� �1.� 32,100 26.4 13.2 10.4 (2) 2-1/8 40 1,440BNLD06A042 �1.8 �0.� 50,200 39.6 19.8 15.6 (2) 2-1/8 44 1,990BNLD06A048 �8.� ��.5 48,200 39.6 19.8 15.6 (2) 2-1/8 58 2,140BNLD08A056 55.� 5�.� 65,600 52.8 26.4 20.8 (2) 2-1/8 104 2,630BNLD08A065 ��.� ��.� 62,500 52.8 26.4 20.8 (2) 2-5/8 140 2,830BNLD10A071 �0.� ��.5 82,000 66.0 33.8 26.0 (2) 2-5/8 125 3,290BNLD10A083 8�.1 81.5 78,100 66.0 33.0 26.0 (2) 2-5/8 172 3,540BNLD12A100 ��.8 ��.8 93,700 79.2 39.6 31.2 (2) 2-5/8 201 4,230BNLD14A110 110.0 10�.� 109,300 92.4 46.2 36.4 (4) 2-5/8 236 4,910

11�0 series Model BnH, 11�0 RPM, 1.5 HP, �0” fan diameter

BnHModel

tHR, MBH/1°f tdcfM

total fLaconnections

(in.)

Refrigerantsummer charge

R-�� (lbs.)

approx.net Wt.

(lbs.)R-�� R-�0�a�08

/�/�0��0

/�/�05�5

/�/�0single Row

BNHS01A007 �.� �.� 9,900 7.0 3.5 2.8 1-3/8 8 330BNHS01A009 8.� 8.� 9,500 7.0 3.5 2.8 1-3/8 10 360BNHS02A011 10.� 10.5 20,500 14.0 7.0 5.6 1-3/8 10 580BNHS02A015 1�.5 1�.� 19,800 14.0 7.0 5.6 1-5/8 15 630BNHS02A017 1�.1 1�.� 19,000 14.0 7.0 5.6 2-1/8 29 680BNHS03A022 �1.8 �1.� 29,700 21.0 10.5 8.4 2-1/8 22 930BNHS03A026 �5.� �5.� 28,500 21.0 10.5 8.4 2-1/8 30 1,000BNHS04A029 ��.1 �8.5 38,600 28.0 14.0 11.2 2-1/8 51 1,210BNHS04A034 ��.� ��.5 37,000 28.0 14.0 11.2 2-5/8 70 1,310BNHS05A037 ��.1 ��.� 48,300 35.0 14.0 14.0 2-5/8 64 1,510BNHS05A044 ��.0 ��.1 46,200 35.0 17.5 14.0 2-5/8 86 1,640BNHS06A053 5�.8 51.� 55,400 42.0 17.5 16.8 2-5/8 102 1,950BNHS07A061 �1.0 5�.8 64,700 49.0 21.0 19.6 (2) 2-5/8 118 2,240

double RowBNHD04A021 �1.� �1.0 41,000 28.0 24.5 11.2 (2) 1-3/8 19 1,240BNHD04A029 ��.1 �8.5 39,600 28.0 14.0 11.2 (2) 1-5/8 29 1,340BNHD04A034 ��.� ��.5 38,100 28.0 14.0 11.2 (2) 2-1/8 40 1,440BNHD06A044 ��.� ��.8 59,400 42.0 21.0 16.8 (2) 2-1/8 44 1,990BNHD06A051 51.� 50.� 57,100 42.0 21.0 16.8 (2) 2-1/8 58 2,140BNHD08A058 58.� 5�.0 77,200 56.0 28.0 22.4 (2) 2-1/8 104 2,630BNHD08A068 �8.� ��.1 73,900 56.0 28.0 22.4 (2) 2-5/8 140 2,830BNHD10A074 ��.� ��.� 96,500 70.0 35.0 28.0 (2) 2-5/8 125 3,290BNHD10A088 88.0 8�.� 92,400 70.0 35.0 28.0 (2) 2-5/8 172 3,540BNHD12A106 105.� 10�.5 110,900 84.0 42.0 33.6 (2) 2-5/8 201 4,230BNHD14A122 1�1.� 11�.5 129,400 98.0 49.0 39.2 (4) 2-5/8 236 4,910

air-cooled condensers

Bold indicates standard model capacity at 10 FPI

Bold indicates standard model capacity at 10 FPI

Page 35: Catalogo

�5

Belt-drive condensers �5 - ��8 tons

Model BVf belt-drive condenser offers maximum reliability and performance in a wide capacity range from 45 - 228 nominal tons.

features• Heavy gauge, gusset-reinforced casings — corrosion-resistant• Spun venturi for strength and quiet air flow• Heavy galvanized steel mounting frame (Sizes 45-228)• Copper tube, aluminum fin condenser coils• Balanced, heavy-duty fans treated for corrosion resistance• Motors thermally protected; ball bearings permanently lubricated• Rigid motor mounts located inside casing for protection• Plated, dipped, steel wire guards for corrosion resistance• Weatherproof junction box outside unit casing• Motor access panels in casing make maintenance routine• Multi-circuiting available at no additional cost

options• Connection manifold kit• Extended lubricating lines• Copper tube/copper fin coils; BohnGuard® and polyester baked

phenolic coating• Coils with alternate fin spacings• A wide variety of low ambient operation controls include fan cycling,

Limitizer and combination fan cycling/Limitizer® systems

air-cooled condensers

BVfModel

condenser cap. MBH(R-��)* fan dimensions

(in.)connections

(in.) approx. net Wt.

(lbs.)tHR�0°f td

tHR/circ.1°f td

tube circ.available Qty. HP total fLa

��0V. L H d inlet outlet

BVF45 693 0.6 (2) 19 2 1-1/2 10.0 114 62-1/2 86 (2) 1-3/8 (2) 1-3/8 1,280BVF50 776 0.7 (2) 19 2 2 12.0 114 62-1/2 86 (2) 1-3/8 (2) 1-3/8 1,340BVF54 822 0.7 (2) 19 2 2 12.0 114 62-1/2 86 (2) 1-3/8 (2) 1-3/8 1,380BVF57 868 0.8 (2) 19 2 5 26.4 114 62-1/2 86 (2) 1-3/8 (2) 1-3/8 1,370BVF59 899 0.6 (2) 26 2 2 12.0 114 62-1/2 86 (2) 1-5/8 (2) 1-5/8 1,540BVF62 944 0.8 (2) 19 2 5 26.4 114 62-1/2 86 (2) 1-3/8 (2) 1-3/8 1,420BVF65 990 0.9 (2) 19 2 5 26.4 114 62-1/2 86 (2) 1-3/8 (2) 1-3/8 1,450BVF69 1,055 0.9 (2) 19 3 1-1/2 15.0 169 62-1/2 86 (2) 1-5/8 (2) 1-5/8 1,860BVF73 1,112 0.7 (2) 26 2 5 26.4 114 62-1/2 86 (2) 1-5/8 (2) 1-5/8 1,610BVF81 1,234 1.1 (2) 19 3 2 18.0 169 62-1/2 86 (2) 1-5/8 (2) 1-5/8 2,110BVF86 1,309 1.1 (2) 19 3 5 39.6 169 62-1/2 86 (2) 1-5/8 (2) 1-5/8 2,095BVF88 1,340 0.9 (2) 26 3 2 18.0 169 62-1/2 86 (2) 1-5/8 (2) 1-5/8 2,335BVF96 1,462 0.9 (2) 26 3 3 25.2 169 62-1/2 86 (2) 1-5/8 (2) 1-5/8 2,380BVF 97 1,477 1.3 (2) 19 3 5 39.6 169 62-1/2 86 (2) 1-5/8 (2) 1-5/8 2,395BVF101 1,538 0.8 (2) 32 3 3 25.2 169 62-1/2 86 (2) 2-1/8 (2) 2-1/8 2,460BVF106 1,614 1.0 (2) 26 3 5 39.6 169 62-1/2 86 (2) 1-5/8 (2) 1-5/8 2,440BVF111 1,697 1.1 (2) 26 4 2 24.0 224 62-1/2 86 (2) 2-1/8 (2) 2-1/8 2,910BVF114 1,736 0.9 (2) 32 3 5 39.6 169 62-1/2 86 (2) 2-1/8 (2) 2-1/8 2,580BVF121 1,849 1.2 (2) 26 4 3 33.6 224 62-1/2 86 (2) 2-1/8 (2) 2-1/8 2,970BVF136 2,071 1.1 (2) 32 4 3 33.6 224 62-1/2 86 (2) 2-1/8 (2) 2-1/8 3,370BVF139 2,117 1.4 (2) 26 4 5 52.8 224 62-1/2 86 (2) 2-1/8 (2) 2-1/8 3,050BVF145 2,209 1.4 (2) 26 5 2 30.0 279 62-1/2 86 (2) 2-1/8 (2) 2-1/8 3,850BVF151 2,300 1.2 (2) 32 4 5 52.8 224 62-1/2 86 (2) 2-1/8 (2) 2-1/8 3,450BVF159 2,416 1.5 (2) 26 5 3 42.0 279 62-1/2 86 (2) 2-1/8 (2) 2-1/8 3,900BVF167 2,545 1.6 (2) 26 6 2 36.0 334 62-1/2 86 (2) 2-5/8 (2) 2-5/8 4,525BVF179 2,726 1.7 (2) 26 5 5 66.0 279 62-1/2 86 (2) 2-1/8 (2) 2-1/8 3,950BVF182 2,773 1.8 (2) 26 6 3 50.4 334 62-1/2 86 (2) 2-5/8 (2) 2-5/8 4,575BVF200 3,044 1.6 (2) 32 6 3 50.4 334 62-1/2 86 (2) 2-5/8 (2) 2-5/8 4,995BVF209 3,183 2.0 (2) 26 6 5 79.2 334 62-1/2 86 (2) 2-5/8 (2) 2-5/8 4,695BVF228 3,471 1.8 (2) 32 6 5 79.2 334 62-1/2 86 (2) 2-5/8 (2) 2-5/8 5,115

*For R-404A, R-502 and R-507, multiply MBH by 0.98

BVf Model

Page 36: Catalogo

��

Belt-drive fluid coolers

Model Bff fluid coolers are an economical unit of choice for several commercial and industrial applications. Using the “free” colder-than-fluid ambient air for initial cooling or total heat removal in the winter months can save on operating costs. The simple design of Bohn’s fluid coolers, and available options for multiple use make it an ideal choice for any system design.

Options include:• Fan cycling for low ambient operation efficiency• Surge tank to protect from water hammer• Pump mounting base and weather shield• Fill valve assembly ease owner’s installation time• Optional cooling coils, including wider fin spacing for ease of cleaning,

BohnGuard® coated fins, baked phenolic coating, or all copper for corrosive or adverse atmospheres

Belt-drive units are available in a variety of sizes. A belt-drive design may be ideal for a highly industrial application, or wherever regular maintenance and equipment inspections take place. The rugged design and quiet, 4-pole motors make model BFF an excellent option for fluid cooler customers.

fluid coolers

BffModel

cfMVol.

ingal.

Base capacity Range @ 1°f td,�0% glycol (1�0° average temp) Motor

dimensions(in.)

approx.dry

net Wt. (lbs.)

Minimum Maximum

gPM MBH Pd/f gPM MBH Pd/f Qty. HPtotal fLa

��0V.L H d

BFF45 32,800 19.3 30 10.90 3.3 250 21.53 20.9 2 1-1/2 10.0 114 62-1/2 86 1,280BFF50 35,000 19.3 30 11.40 3.3 250 24.16 20.9 2 2 12.0 114 62-1/2 86 1,340BFF54 34,400 19.3 30 11.67 3.3 250 25.47 20.9 2 2 12.0 114 62-1/2 86 1,380BFF57 51,200 19.3 30 11.60 3.3 250 26.65 20.9 2 5 26.4 114 62-1/2 86 1,370BFF59 31,200 24.3 40 14.89 3.4 250 26.79 13.2 2 2 12.0 114 62-1/2 86 1,540BFF62 50,100 19.3 30 11.92 3.3 250 28.80 21.0 2 5 26.4 114 62-1/2 86 1,420BFF65 48,200 19.3 30 12.13 3.3 250 30.27 21.0 2 5 26.4 114 62-1/2 86 1,450BFF69 44,000 26.3 40 15.57 5.3 200 29.70 19.9 3 1-1/2 15.0 169 62-1/2 86 1,960BFF73 49,200 24.3 40 15.76 3.5 300 33.91 18.3 2 5 26.4 114 62-1/2 86 1,610BFF81 51,600 26.3 40 16.53 5.3 200 34.72 20.0 3 2 18.0 169 62-1/2 86 2,110BFF86 76,800 26.3 40 16.42 5.3 200 35.71 20.0 3 5 39.6 169 62-1/2 86 2,095BFF88 46,800 33.7 50 19.40 2.3 350 39.67 16.4 3 2 18.0 169 62-1/2 86 2,335BFF96 54,300 33.7 50 19.82 2.3 350 43.35 16.4 3 3 25.2 169 62-1/2 86 2,380BFF97 72,300 26.3 40 17.06 5.3 200 40.11 20.1 3 5 39.6 169 62-1/2 86 2,395

BFF101 58,800 41.1 50 20.82 2.9 300 47.01 16.9 3 3 25.2 169 62-1/2 86 2,460BFF106 66,000 26.3 50 20.27 2.3 350 48.19 16.4 3 5 39.6 169 62-1/2 86 2,440BFF111 72,000 43.1 50 20.74 3.0 300 46.39 16.0 4 2 24.0 224 62-1/2 86 2,910BFF114 67,600 41.1 50 21.23 2.9 300 52.29 17.0 3 5 39.6 169 62-1/2 86 2,580BFF121 78,000 43.1 50 21.04 3.0 300 49.67 16.0 4 3 33.6 224 62-1/2 86 2,970BFF136 82,400 52.9 50 22.54 3.7 250 60.84 16.0 4 3 33.6 224 62-1/2 86 3,370BFF139 99,200 43.1 50 21.44 3.0 350 57.51 21.0 4 5 52.8 224 62-1/2 86 3,050BFF145 81,500 52.5 50 22.21 3.7 300 58.57 19.5 5 2 30.0 279 62-1/2 86 3,850BFF151 100,400 52.9 50 22.71 3.8 300 70.69 22.0 4 5 52.8 224 62-1/2 86 3,450BFF159 94,000 52.5 50 22.38 3.7 300 62.59 19.6 5 3 42.0 279 62-1/2 86 3,900BFF167 101,400 62.0 40 18.30 3.0 300 64.78 23.1 6 2 36.0 334 62-1/2 86 4,525BFF179 114,500 52.5 50 22.57 3.7 300 67.91 19.6 5 5 66.0 279 62-1/2 86 3,950BFF182 117,000 62.0 40 18.36 3.0 300 68.74 23.1 6 3 50.4 334 62-1/2 86 4,575BFF200 123,600 76.4 40 18.65 3.7 250 77.54 23.4 6 3 50.4 334 62-1/2 86 4,995BFF209 142,200 62.0 40 18.43 3.0 250 68.49 16.9 6 5 79.2 334 62-1/2 86 4,695BFF228 150,600 76.4 40 18.67 3.7 250 82.50 23.4 6 5 79.2 334 62-1/2 86 5,115

Connection sizes: BFF 45-139, 2 @ 2-1/8 OD copper BFF 145-228, 2 @ 3-1/8 OD copper

Bff Model

Page 37: Catalogo

��

direct-drive fluid coolers

Model BfH (available in vertical air flow only) and dft (horizontal or vertical air flow available) direct-drive fluid coolers are easy to install and maintain, yet are ruggedly designed to handle all applications. Available in a variety of sizes, the BFH and DFT units have design features ideal for the commercial/industrial locations. Specifically engineered for outdoor installations, the cabinet is constructed of heavy gauge aluminum or pre-painted galvanized steel to resist corrosion in all climates. Additional design features include:

• Fully baffled fan sections to prevent windmilling• Single-point wiring to junction box• Balanced fans, featuring heavy gauge aluminum blades riveted to plated steel spiders

fluid coolers

BfHModel cfM

Vol.in

gal.

Base capacity Range @ 1°f td,�0% glycol (1�0° average temp) Motor dimensions

(in.)connections

ods (in.)

approx.dry

net Wt.(lbs.)

Minimum MaximumQty. HP

fLa

gPM MBH Pd/f gPM MBH Pd/f ��0V. ��0V. L H d inlet outlet

single RowBFH023BFH027

23,00023,200

6.79.2

2020

6.407.01

3.24.8

120180

11.6913.34

10.710.7

22

1-1/21-1/2

14.014.0

7.07.0

120-1/2120-1/2

5050

45-1/245-1/2

2-5/83-1/8

2-5/83-1/8

730 770

BFH031BFH035BFH041

21,90020,70034,800

9.211.813.0

203020

7.4210.208.19

4.86.67.0

180240180

14.8916.7919.40

10.710.715.7

223

1-1/21-1/21-1/2

14.014.021.0

7.07.0

10.5

120-1/2120-1/2175-1/2

505050

45-1/245-1/245-1/2

3-1/83-5/83-1/8

3-1/83-5/83-1/8

790 8801,190

BFH045BFH049BFH053

32,90031,80046,400

13.016.716.7

303020

11.1511.928.71

4.69.59.2

180240180

21.6623.7425.09

15.715.720.8

334

1-1/21-1/21-1/2

21.021.028.0

10.510.514.0

175-1/2175-1/2230-1/2

505050

45-1/245-1/245-1/2

3-1/83-5/83-1/8

3-1/83-5/83-1/8

1,2101,2401,580

BFH061BFH065BFH071

43,90042,40041,500

16.721.721.7

303030

12.3412.8813.04

6.112.512.5

180240240

27.9330.8932.13

20.820.820.8

444

1-1/21-1/21-1/2

28.028.028.0

14.014.014.0

230-1/2230-1/2230-1/2

505050

45-1/245-1/245-1/2

3-1/83-5/83-5/8

3-1/83-5/83-5/8

1,6201,6501,760

BFH075BFH079BFH089BFH097

54,90054,80051,80065,800

20.426.626.631.6

30303040

12.9713.2013.4017.22

7.515.415.48.9

180240240220

33.6935.8939.1241.02

25.825.825.826.4

5556

1-1/21-1/21-1/21-1/2

35.035.035.042.0

17.517.517.521.0

285-1/2285-1/2285-1/2340-1/2

50505050

45-1/245-1/245-1/245-1/2

3-1/83-5/83-5/83-5/8

3-1/83-5/83-5/83-5/8

2,0202,0002,2002,390

BFH107 62,200 31.6 40 17.59 8.9 220 44.66 26.4 6 1-1/2 42.0 21.0 340-1/2 50 45-1/2 3-5/8 3-5/8 2,630double Row

BFH046BFH054BFH060

46,00046,40043,900

13.518.518.5

304040

11.2414.0314.84

6.64.84.8

240280280

23.3825.4928.37

10.76.96.9

444

1-1/21-1/21-1/2

28.028.028.0

14.014.014.0

120-1/2120-1/2120-1/2

505050

888888

(2) 2-5/8(2) 2-5/8(2) 2-5/8

(2) 2-5/8(2) 2-5/8(2) 2-5/8

1,5401,5801,620

BFH066BFH070BFH080

42,40041,50069,700

23.523.525.9

505040

17.7718.2116.38

4.84.87.0

280280280

29.5130.6736.79

4.14.1

10.1

446

1-1/21-1/21-1/2

28.028.042.0

14.014.021.0

120-1/2120-1/2175-1/2

505050

888888

(2) 2-5/8(2) 2-5/8(2) 2-5/8

(2) 2-5/8(2) 2-5/8(2) 2-5/8

1,6501,7602,360

BFH086BFH090BFH090

67,00065,80063,600

25.925.933.4

404050

16.6916.9320.73

7.07.06.9

280280280

38.9440.8342.48

10.110.16.1

666

1-1/21-1/21-1/2

42.042.042.0

21.021.021.0

175-1/2175-1/2175-1/2

505050

888888

(2) 2-5/8(2) 2-5/8(2) 2-5/8

(2) 2-5/8(2) 2-5/8(2) 2-5/8

2,3802,4202,480

BFH106BFH120BFH132

92,90087,80084,800

33.333.343.3

404050

17.4217.7421.96

9.29.29.0

280280280

47.0652.1054.16

13.313.38.0

888

1-1/21-1/21-1/2

56.056.056.0

28.028.028.0

230-1/2230-1/2230-1/2

505050

888888

(2) 2-5/8(2) 2-5/8(2) 2-5/8

(2) 2-5/8(2) 2-5/8(2) 2-5/8

3,1503,2303,300

BFH140BFH152BFH162

83,000109,700109,700

43.340.753.1

506050

22.1325.9422.33

9.07.5

11.2

280280280

56.2462.1761.86

8.016.59.9

81010

1-1/21-1/21-1/2

56.070.070.0

28.035.035.0

230-1/2285-1/2285-1/2

505050

888888

(2) 2-5/8(2) 2-5/8(2) 2-5/8

(2) 2-5/8(2) 2-5/8(2) 2-5/8

3,5104,0403,990

BFH168BFH178BFH194

106,000103,700131,600

53.153.163.1

508080

22.4534.0634.44

11.27.58.9

280280280

64.5966.9970.79

9.99.9

11.9

101012

1-1/21-1/21-1/2

70.070.084.0

35.035.042.0

285-1/2285-1/2340-1/2

505050

888888

(2) 2-5/8(2) 2-5/8(2) 2-5/8

(2) 2-5/8(2) 2-5/8(2) 2-5/8

4,1304,3904,790

BFH202BFH212

127,200124,400

63.163.1

8080

34.8635.17

8.98.9

280280

73.8276.46

11.911.9

1212

1-1/21-1/2

84.084.0

42.042.0

340-1/2340-1/2

5050

8888

(2) 2-5/8(2) 2-5/8

(2) 2-5/8(2) 2-5/8

4,9605,270

dft Model

*Motors also available in 230/1, 460/3 and 575/3

BfH Model

dftModel cfM

Vol.in

gal.

Base capacity Range @ 1°f td,�0% glycol (1�0° average temp) Motor dimensions

(in.)connections

ods (in.)

approx. dry

net Wt.(lbs.)

Minimum MaximumQty. HP ��0/

�*gPM MBH Pd/f gPM MBH Pd/f L H d inlet outletDFT005 5,050 3 10 2.23 4.7 30 2.97 15.5 1 1/3 2.6 39-3/4 40-1/2 43 1-3/8 1-3/8 180DFT008 6,450 4 10 3.07 7.4 60 4.62 13.0 1 1/3 2.6 49-3/4 40-1/2 43 1-5/8 1-5/8 260DFT010 10,100 4 10 3.46 7.5 60 6.10 28.2 2 1/3 5.2 69-3/4 40-1/2 43 2-1/8 2-1/8 450DFT012 12,400 4 10 3.62 7.5 60 6.88 28.2 2 1/3 5.2 69-3/4 40-1/2 43 2-1/8 2-1/8 470DFT014 13,700 5 10 3.92 9.4 50 7.64 25.2 2 1/3 5.2 89-3/4 40-1/2 43 2-1/8 2-1/8 510DFT016 12,900 6 10 4.17 12.4 60 8.70 20.9 2 1/3 2.5 89-3/4 40-1/2 43 2-1/8 2-1/8 530DFT021 20,500 7 15 5.93 12.3 120 12.31 25.7 3 1/3 7.8 129-3/4 40-1/2 43 2-5/8 2-5/8 550DFT023 19,900 7 20 6.99 6.8 120 12.94 25.7 3 1/3 7.8 129-3/4 40-1/2 43 2-5/8 2-5/8 580DFT026 19,400 9 20 7.65 12.9 160 14.08 25.7 3 1/3 7.8 129-3/4 40-1/2 43 2-5/8 2-5/8 625

Page 38: Catalogo

�8

More Products and technology from Bohn

ServiceMate™ is an innovative standard feature that provides immediate visual feedback on the status of system control components. This results in reduced diagnostic time and equipment downtime, which translates into cost savings on service calls for customers and time savings for contractors. ServiceMate™ comes standard on all 3-80 HP air-cooled, Discus® and Scroll® condensing units.

ServiceMate™

Why should you be concerned with choosing energy efficiency? Because it’s smart. Not just for your bottom line, but also for the environment. Heatcraft Refrigeration Products provides energy-efficient solutions with evaporators, air-cooled condensers, Beacon II™ Smart Defrost and others. Look for the Energy Solutions® logo to identify energy-efficient products and features that will help you save money by conserving energy.

Multiple compressorcondensing units

The FlexPack™ provides many features that produce outstanding results for both your refrigeration system and your bottom line.

flexibility for a wide range of applications• Modular design accommodates up to three compressors (1/2-6 HP Hermetic

or Scroll®)• System capacity range from 5 – 18HP (dependent upon cabinet size)

durability and Reliability• 14-gauge galvanized steel frame• 1-year parts warranty• 4-year optional compressor warranty

Reduced installation costs and easy serviceability• Hinged access panels to refrigeration and electrical components• Single roof penetration• Single-point main power• Clean and intuitive electrical and piping layout

energy efficiency and reduced noise• Remote condenser circuits• Reduces heat load into space resulting in lower air conditioning energy costs• Recessed, vertical-discharge, flush-mounted 18” fans with 1100 RPM motors• Reduces noise levels

clean and uniform appearance• Painted G-90 steel cabinet• Small footprint

Page 39: Catalogo

��

Page 40: Catalogo

a Brand of Heatcraft Refrigeration Products LLc�1�5 West Park Place Blvd. • stone Mountain, ga �008�800.5��.���5 • faX ��0.��5.5��0

www.thecoldstandard.com

For more information on Bohn refrigeration products, contact your sales representative or visit us at www.thecoldstandard.com.

Since product improvement is a continuing effort, we reserve the right to make changes in specifications without notice.

BN-CC-0407 | version 000