catalog hy15-3501/us contents proportional valves ·  · 2010-07-27catalog hy15-3501/us contents...

67
Catalog HY15-3501/US Proportional Valves Contents Parker Hannifin Corporation Hydraulic Cartridge Systems Check Valves Shuttle Valves Load/Motor Controls Flow Controls Pressure Controls Logic Elements Directional Controls Manual Valves Solenoid Valves Proportional Valves Coils & Electronics Bodies & Cavities Technical Data SH CV LM FC PC LE DC MV SV PV CE BC TD SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI PRESSURE RELIEVING AP01B2YP ........ 2G ............... Increase Pressure/Increase Current .............. 5.3/1.4 ...... 350/5000 .............. PV7-PV8 AP02A2 ............ C08-2 .......... Increase Pressure/Increase Current .................. 30/8 ...... 350/5000 ............ PV9-PV10 AP04G2YP ........ C10-2 .......... Increase Pressure/Increase Current ................ 45/12 ...... 350/5000 .......... PV11-PV12 ERV121N .......... C12-2 .......... Increase Pressure/Increase Current .............. 100/25 ...... 210/3000 .......... PV13-PV14 ERV161N .......... C16-2 .......... Increase Pressure/Increase Current .............. 150/40 ...... 210/3000 .......... PV15-PV16 AP01B2YR ........ 2G ............... Decrease Pressure/Increase Current ............. 5.3/1.4 ...... 350/5000 .......... PV17-PV18 AP02B2YR ........ C08-2 .......... Decrease Pressure/Increase Current ............. 5.3/1.4 ...... 350/5000 .......... PV19-PV20 AP04G2YR ....... C10-2 .......... Decrease Pressure/Increase Current ............... 95/25 ...... 350/5000 .......... PV21-PV22 PRESSURE REDUCING GP01 30 ........... 54-1 ............ Pressure Reducing Valve ................................ 1.9/.5 ...... 210/3000 .......... PV23-PV24 GTP02 34 ......... C08-3 .......... Pressure Reducing Valve .................................. 19/5 ...... 210/3000 .......... PV25-PV26 GTP04 34 ......... 3X ............... Pressure Reducing Valve .................................. 30/8 ...... 210/3000 .......... PV27-PV28 FLOW CONTROLS DF122C ............. C12-2 .......... Flow Control, N.C. ........................................... 53/14 ...... 210/3000 .......... PV29-PV30 DF161C ............. C16-2 .......... Flow Control, N.C. ......................................... 150/40 ...... 210/3000 .......... PV31-PV32 DF201C ............. C20-2 .......... Flow Control, N.C. ......................................... 325/60 ...... 210/3000 .......... PV33-PV34 HP02C .............. 2X ............... Flow Control, N.C. ............................................. 23/6 ...... 210/3000 .......... PV35-PV36 JP02C ............... C08-3 .......... Flow Control, N.C. ............................................. 23/6 ...... 210/3000 .......... PV37-PV38 HP04C .............. C10-2 .......... Flow Control, N.C. .......................................... 36/9.5 ...... 210/3000 .......... PV39-PV40 JP04C 21 .......... 3X ............... Flow Control, N.C. .......................................... 36/9.5 ...... 210/3000 .......... PV41-PV42 HP02P .............. 2X ............... Flow Control, N.O. ............................................. 19/5 ...... 210/3000 .......... PV43-PV44 JP02P ............... C08-3 .......... Flow Control, N.O. ............................................. 19/5 ...... 210/3000 .......... PV45-PV46 HP04P .............. C10-2 .......... Flow Control, N.O. ............................................. 30/8 ...... 210/3000 .......... PV47-PV48 JP04P ............... 3X ............... Flow Control, N.O. .......................................... 36/9.5 ...... 210/3000 .......... PV49-PV50 DF122N ............ C12-2 .......... Flow Control, N.O. ........................................... 53/14 ...... 210/3000 .......... PV51-PV52

Upload: hakiet

Post on 17-Apr-2018

239 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Proportional ValvesContents

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.LPM/GPM BAR/PSI

PRESSURE RELIEVINGAP01B2YP ........ 2G ............... Increase Pressure/Increase Current .............. 5.3/1.4 ...... 350/5000 .............. PV7-PV8AP02A2 ............ C08-2 .......... Increase Pressure/Increase Current .................. 30/8 ...... 350/5000 ............ PV9-PV10AP04G2YP ........ C10-2 .......... Increase Pressure/Increase Current ................ 45/12 ...... 350/5000 .......... PV11-PV12

ERV121N .......... C12-2 .......... Increase Pressure/Increase Current ..............100/25 ...... 210/3000 .......... PV13-PV14ERV161N .......... C16-2 .......... Increase Pressure/Increase Current ..............150/40 ...... 210/3000 .......... PV15-PV16

AP01B2YR ........ 2G ............... Decrease Pressure/Increase Current ............. 5.3/1.4 ...... 350/5000 .......... PV17-PV18AP02B2YR ........ C08-2 .......... Decrease Pressure/Increase Current ............. 5.3/1.4 ...... 350/5000 .......... PV19-PV20AP04G2YR ....... C10-2 .......... Decrease Pressure/Increase Current ............... 95/25 ...... 350/5000 .......... PV21-PV22

PRESSURE REDUCINGGP01 30 ........... 54-1 ............ Pressure Reducing Valve ................................ 1.9/.5 ...... 210/3000 .......... PV23-PV24GTP02 34 ......... C08-3 .......... Pressure Reducing Valve .................................. 19/5 ...... 210/3000 .......... PV25-PV26GTP04 34 ......... 3X ............... Pressure Reducing Valve .................................. 30/8 ...... 210/3000 .......... PV27-PV28

FLOW CONTROLSDF122C............. C12-2 .......... Flow Control, N.C. ........................................... 53/14 ...... 210/3000 .......... PV29-PV30

DF161C............. C16-2 .......... Flow Control, N.C. ......................................... 150/40 ...... 210/3000 .......... PV31-PV32DF201C............. C20-2 .......... Flow Control, N.C. ......................................... 325/60 ...... 210/3000 .......... PV33-PV34

HP02C .............. 2X ............... Flow Control, N.C. ............................................. 23/6 ...... 210/3000 .......... PV35-PV36JP02C ............... C08-3 .......... Flow Control, N.C. ............................................. 23/6 ...... 210/3000 .......... PV37-PV38HP04C .............. C10-2 .......... Flow Control, N.C. .......................................... 36/9.5 ...... 210/3000 .......... PV39-PV40JP04C 21 .......... 3X ............... Flow Control, N.C. .......................................... 36/9.5 ...... 210/3000 .......... PV41-PV42

HP02P .............. 2X ............... Flow Control, N.O. ............................................. 19/5 ...... 210/3000 .......... PV43-PV44JP02P ............... C08-3 .......... Flow Control, N.O. ............................................. 19/5 ...... 210/3000 .......... PV45-PV46HP04P .............. C10-2 .......... Flow Control, N.O. ............................................. 30/8 ...... 210/3000 .......... PV47-PV48JP04P ............... 3X ............... Flow Control, N.O. .......................................... 36/9.5 ...... 210/3000 .......... PV49-PV50

DF122N ............ C12-2 .......... Flow Control, N.O. ........................................... 53/14 ...... 210/3000 .......... PV51-PV52

Page 2: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Proportional ValvesContents

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.LPM/GPM BAR/PSI

FLOW CONTROL, 3-WAYDF083N ............ C08-3 .......... Flow Control, 3-Way .......................................... 11/3 ...... 210/3000 .......... PV53-PV54

JP04C 31 .......... 4C ............... Priority Flow Control, N.C. ................................. 30/8 ...... 210/3000 .......... PV55-PV56

DIRECTIONAL CONTROLGP02 51 ........... C08-4 .......... 4 Way, 3 Pos - Closed Center ......................... 21/5.5 ...... 350/5000 .......... PV57-PV58GP04 51 ........... C10-4 .......... 4 Way, 3 Pos - Closed Center ......................... 32/8.5 ...... 350/5000 .......... PV59-PV60

GP02 53 ........... C08-4 .......... 4 Way, 3 Pos - Float Center ............................ 17/4.5 ...... 350/5000 .......... PV61-PV62GP04 53 ........... C10-4 .......... 4 Way, 3 Pos - Float Center ............................. 38/10 ...... 350/5000 .......... PV63-PV64

Page 3: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

PV1

Proportional Control ValvesCatalog HY15-3501/US

Technical Tips

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

INTRODUCTIONThis technical tips section is designed to help familiarize you with the Parker line of Proportional Valves. In thissection we present common options, technical terms, as well as a brief synopsis of the operation and applicationsof the various products offered in this section. The intent of this section is to help you in selecting the bestproducts for your application.

Seals: The majority of the products are available inNitrile or Fluorocarbon Seals. The Winner’s Circleproducts feature a standard 4301 Polyurethane“D”-Ring. The “D”-Ring eliminates the need for backuprings. You should match the seal compatibility to thetemperature and fluid being used in your application.

Overrides: Overrides are standard on many of theParker proportional valves. The override is generally apush type that is flush with the end of the tube. Consultthe individual catalog pages for more details.

TECHNICAL TERMSTo help in applying our proportional valve line ofproduct, we have listed some technical terms below,as well as some helpful hints in applying our valves.

Ohm’s Law: Electrical current is generated as a resultof the relationship between input voltage and theresistance to the flow of electrical current. It isrepresented in equation form by I = V/R (or V=IR),where I is current, V is voltage and R is resistance.This is an important relationship to remember whendealing with any electrically operated valves.Proportional valves allow varying control of flow orpressure, dependant on the current signal provided.As coils heat up, their resistance rises. This means ahigher voltage must be available to maintain the sameamount of pressure or flow. Thus, the applicationneeds to be designed such that the full on position isabout 70% of the initial current draw. On the individualcatalog pages a maximum control current is specifiedto help in applying our proportional valves.

PWM: Pulse Width Modulation (PWM) is the preferredsignal for controlling electrical current. PWM is on / offvoltage in a square wave form. The percent “on” timeor duty cycle provides the average voltage. The valvedriver adjusts the duty cycle to obtain current control.We recommend valve drivers with current control foroptimum performance. PWM signals also usuallyprovide dither for the proportional valve. Dither is a

small back and forth movement of the valve spoolaround its set position. This rapid movement reducesthe friction of the valve and leads to faster, moreaccurate response.

PWM Frequency: The frequency of a PWM signal isthe rate at which the signal is turned on and off.Parker’s analog proportional valves are designed towork with low frequency responses between 100-400Hz. The performance curves on our catalog pageswere performed with a PWM signal at 200 Hz.

Hysteresis: Due to various factors, the performanceof a proportional valve will show a slightly differentperformance when the current signal is increasing thanit will when the signal is being decreased. Thisdifference is usually expressed as a percentage oftotal input change and is referred to as the hysteresisof the valve.

Deadband: Cracking or deadband refers to theamount of the control signal that is needed to produceany movement of the spool. Thus, a 20% deadbandmeans that 20% of the control signal is needed beforethe spool will move.

COMMON OPTIONSAs you will see, Parker offers a variety of Proportional Valve products. As such, some of the options mentionedbelow may not be available on all valves. Consult the model coding and dimensions for each valve for specifics.Here are some of the common options available.

Page 4: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

PV2

Catalog HY15-3501/US

Proportional Control ValvesTechnical Tips

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

PRODUCT TYPES / APPLICATIONSProportional valves are nothing more than electrically adjustable hydraulic valves. They give the operator nearlyinfinite adjustment control and flexibility. Parker Hannifin offers various types of proportional flow control, pressurereducing, and relief valves.

Proportional Flow Control ValveProportional flow control valves provide pseudo pressure compensation and are used on systems requiringvariable electronic control of flow. They allow the operator to vary the control signal to accelerate or decelerate anactuator. A compensator valve can be added to the circuit for enhanced compensation. Some typical applicationswould include the hoist control for a lift, or the speed control for a winch circuit. Parker offers both normally closedand normally open versions of proportional flow controls.

Normally ClosedProportional Flow Control

OPERATION - With the solenoidcoil de-energized, the spool is held ina closed position by the spring force. When thesolenoid coil is energized, the amperage of thesignal moves the spool into an open position.The spool is held in this position by a balance between spring force and electrical force. As the current increases,the spools opens further; allowing more flow. As the current decreases, the spool begins closing; allowing lessflow. Pseudo compensation is obtained by the pressure drop across the orifices in the spool.

Normally OpenProportional Flow Control

OPERATION - With the solenoidcoil de-energized, the spool is held inan open position by spring force; allowing full flowto pass. As the solenoid coil is energized, the spoolbegins to move away from a full open position;allowing less flow to pass. Once a full electronic signal is given, the spool is held in a closed position; allowing noflow to pass. As the electronic signal is then reduced, the spool begins to open; allowing flow to pass again. Oncea constant electronic signal is given, the spool is held in that position by a balance between electronic force andspring force. Pseudo compensation is obtained by the pressure drop across the orifices in the spool.

Normally ClosedProportional Needle ValveThe proportional needle valvesare electronic controlled variableneedle valves. They are designedspecifically for bleed off or unloadingcircuits as back pressure will affect performance.

OPERATION - With the solenoid de-energized, the mainpoppet is held in the closed position by spring force. Whenthe solenoid is energized, the sensing spool moves into a partially open position relative to the percentage ofrated current flowing through the coil. This action allows the main poppet to move away from the valve seat to adegree that corresponds to sensing spool position. The valve will maintain a fixed amount of opening as long asthe electrical current remains constant and will vary proportionally with an increase or decrease in current.

Out(1)

In (2)

In(1)

Out (2)

Inlet (2)

Outlet(1)

Page 5: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

PV3

Proportional Control ValvesCatalog HY15-3501/US

Technical Tips

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Proportional PriorityBypass Flow ControlThe proportional priority bypassflow controls allow electroniccontrol of the flow setting for thepriority flow circuit. The priorityflow remains constant regardless ofchanges in load or pressure. The excess inlet flow is divertedor bypassed to tank. The bypass port must not have any restrictions or performance will be hindered.

OPERATION - Flow enters the valve through port 3. With the coil de-energized, flow is bypassed to port 2. Whenthe coil is energized, the internal orifice is increased allowing pressure compensated flow to the priority port (port4). The excess flow is bypassed to port 2. As input current is increased, the priority flow increases and the bypassflow decreases. As the current is decreased, priority flow decreases and bypass flow is increased.

Proportional 3-WayFlow ControlProportional 3-Way flow controlsallow the user to control the flow ona three way circuit. It can be used aseither a normally open or normally closedthree way valve. They are well suited forcircuits requiring acceleration or deceleration control.

OPERATION - Normally Closed (Port 2 to Port 1) With the solenoid coil de-energized, the spool is held in aclosed position by the spring force. When the solenoid coil is energized, the amperage of the signal moves thespool to an open position. The spool is held in this position by a balance between spring force and electrical force.As the electrical force increases, the spool opens further; allowing more flow. As the electrical force decreases,the spool begins closing; allowing less flow.Normally Open (Port 1 to Port 3) With the solenoid coil de-energized, the spool is held in an open position by thespring force; allowing full flow to pass. As the solenoid coil is energized, the spool begins to move away from a fullopen position; allowing less flow to pass. Once a full electronic signal is given, the spool is held in a closedposition; allowing no flow to pass. As the electrical signal is then reduced, the spool begins to open; allowing flowto pass once again. Once a constant electronic signal is given, the spool is held in that position by a balancebetween electronic force and spring force.

Direct Acting,Normally Closed ProportionalPressure Reducing ValveDirect acting, normally closedproportional pressure reducingvalves are used to electronically reduce the inletpressure to one leg of a hydraulic circuit. This valve is usedwhen a fixed regulated pressure is required regardless of the inlet pressure. This valve could be used as a clutchcontrol for power shift transmissions and PTO, or as a pilot control for directional control valves.

OPERATION - With the solenoid coil de-energized, the spool is held in a closed position by spring force. In thismode, the regulated pressure port is open to tank and the pressure inlet is blocked. As current is applied to thesolenoid coil, the spool will begin to travel to a position where the pressure inlet port is connected to the regulatedpressure port. At this point, reduced pressure becomes a function of the current signal. As long as the currentsignal is constant, the reduced pressure at the regulated pressure port will remain fixed regardless of anychanges in inlet flow or inlet pressure. As the current signal increases or decreases, the reduced pressure at theregulated pressure port will change with respect to the changes in signal. Once the coil is fully energized, thereduced pressure of the regulated pressure port will be at the maximum reduced pressure for that valve.

(1)

(3)(2)

T (1)

(3) PAct. (2)

Not Used(1)

Bypass(2)

Inlet(3)

Reg.(4)

Page 6: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

PV4

Catalog HY15-3501/US

Proportional Control ValvesTechnical Tips

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Normally Closed Proportional Pressure Reducing / Relieving ValveNormally Closed Proportional Pressure Reducing/Relieving Valves are used to electronically reduce the inlet pres-sure to one leg of a hydraulic circuit. In addition these valves act as a relief valve, relieving any shocks or surgesthat occur between its regulating port and the actuator. Parker offers direct acting and pilot operated versions ofthis valve. The direct acting valves are faster responding and generally have lower hysteresis, but are limited tosmaller reduced pressures (generally below 800 psi depending on the valve.) Pilot operated are generally sloweron response due to the two stage performance, but can have a reduced pressure as high as 3000 psi.

Direct Acting

OPERATION - With the solenoidcoil de-energized, the spool is heldin a closed position by spring force.In this mode, the regulated pressure port is open to tankand the pressure inlet port is blocked. As an electronicsignal is applied to the solenoid coil, the spool will beginto travel to a position where the pressure inlet port is connected to the regulated pressure port. At this point,reduced pressure becomes a function of the voltage signal. As long as the electronic signal is constant, thereduced pressure at the regulated pressure port will remain fixed regardless of any changes in inlet flow or inletpressure. As the electronic signal increases or decreases, the reduced pressure at the regulated port will changewith respect to the change in electronic signal. Once a full signal is given, the reduced pressure of the regulatedpressure port will be at the maximum reduced pressure for that valve.

Pilot Operated

OPERATION - With the solenoidcoil de-energized, the pilot dart isheld open by the spring force. Thisallows the main spool to close and restricts flow fromgoing from the inlet (2) port to the regulated port (1).As the electronic signal is applied to the coil, the pilot dartis moved towards the pilot seat restricting pilot flow. Thisrestriction raises the effective pressure inside the chamber between the spool and the pilot seat, allowing thespool to travel away from the pilot seat to a position where the pressure at inlet (2) is connected to the regulatedpressure port (1). At this point, reduced pressure becomes a function of the electronic signal. As long as theelectronic signal is constant, the reduced pressure at the regulated pressure port (2) will remain fixed regardlessof any changes in inlet flow or inlet pressure. As the electronic signal increases or decreases, the reducedpressure at port (1) will change with respect to the change in the electronic signal.

Reg.(1)

(3) TankPressure (2)

Reg.(1)

(3) TankIn (2)

Page 7: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

PV5

Proportional Control ValvesCatalog HY15-3501/US

Technical Tips

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Normally ClosedProportional Relief ValveNormally closed proportional reliefvalves are used to electronicallycontrol the system pressure.These valves are ideal for circuitswith varying system pressuresdemands. A small flow pilot versionof the normally closed proportional relief is also offered forpiloting a larger logic element or vented relief valve. The normallyclosed relief defaults to a maximum pressure setting (i.e. 3000 psi) when there is no current applied.

OPERATION - With the solenoid coil de-energized, the pilot dart is held closed by the spring. As current is appliedto the coil, the pilot dart is moved creating less restriction of the pilot flow. As this restriction is reduced with theincreasing current, the pressure setting also decreases. Once a constant electronic signal is given, the pilot dart isheld in a given position, holding the pressure setting. This is maintained by the balance between the electronicspring force and the inlet pressure.

Normally OpenProportional Relief ValveNormally open proportional reliefvalves are used to electronicallycontrol the system pressure.These valves are ideal for circuitswith varying system pressuredemands. A small flow pilot versionof the normally open proportional relief is also offeredfor piloting a larger logic element or vented relief valve. The normally open relief defaults to minimum systempressure (i.e. 150 psi) when there is no current applied. Normally closed versions are also available upon request.

OPERATION - With the solenoid coil de-energized, the pilot dart is held open by the spring. This allows the mainspool to open at minimum pressure 10.4 Bar (150 psi). As current is applied to the coil, the pilot dart is movedtowards the pilot seat restricting pilot flow. This restriction raises the effective pressure setting of the valve. Oncea constant electronic signal is given, the pilot dart is held in a given position, holding the pressure setting. This ismaintained by a balance between electronic spring force and inlet pressure. As the electronic signal is reduced,the pilot dart is moved away from the pilot seat. This lowers the effective pressure setting of the valve.

(1)

(2)

(1)

(2)

Page 8: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

PV6

Catalog HY15-3501/US

Proportional Control ValvesTechnical Tips

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Notes

Page 9: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV7

Proportional Relief ValveSeries AP01B2YP 07C, 14C, 21C, 35CTechnical Information

Specifications

Rated Flow 07C 5.3 LPM (1.4 GPM)(At 70 PSI ∆∆∆∆∆P) 14C 3.4 LPM (0.9 GPM)

21C 3.0 LPM (0.8 GPM)35C 1.3 LPM (.35 GPM)

Max. Pressure At 07C 70 Bar (1000 PSI)Port 1 @ 75% 14C 140 Bar (2000 PSI)Input Current 21C 210 Bar (3000 PSI)

35C 350 Bar (5000 PSI)

Hysteresis @ 5%200 Hz PWM

Cracking 07C .07 Bar (1 PSI)Pressure 14C .14 Bar (2 PSI)

21C .21 Bar (3 PSI)35C .35 Bar (4 PSI)

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .06 kg (.14 lbs.)

Cavity 2G(See BC Section for more details)

General DescriptionProportional Relief Valve. Increasing Pressure WithIncreasing Current. For additional information seeTechnical Tips on pages PV1-PV6.

Features• Analog Proportional Relief Valve regulates pressure

proportionally to the solenoid current

• Direct acting poppet design

• One piece cartridge housing ensures internalconcentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• All external parts zinc plated

Performance Curves�PWM Current Regulator Recommended

(1) (2) (1)

(2)

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

0

1000

5000 345

205

274

137

68

Pre

ssu

re 3000

4000

PSI Bar

2000

Current (%)

6020 400

80 100

Pressure vs. Input Signal (Current)

-07

-14

-21

-35Measured at coil stabilizedtemperature and nominal flow

Flow (Q)

3.8

1.0

4.5

1.2

0.8

0.2

1.5

0.4

2.3

0.6

3.0

0.8

LPM

GPM0

5.3

1.4

0

80

40

8.6

5.7

2.0

120

200 14.3

11.4160

PSI Bar

Pre

ssu

re D

rop

(P

)

-35

-14

-21

-07

Measured atDe-energized coil

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Pressure Drop vs. Flow

Page 10: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Relief ValveSeries AP01B2YP 07C, 14C, 21C, 35C

PV8

Technical Information

SealsOverrideOption

CoilType

CoilTermination

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Seals / Kit No.N Nitrile / Buna-N (Std.)

(SK30129N-1)V Fluorocarbon /

(SK30129V-1)E Ethylene Propylene

CoilVoltage

AP01B2YP08 Size

ProportionalRelief Valve

Style

Code Override OptionOmit Not Required (Std.)

1 Manual Override

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style (MaximumRelief Pressure)

07C 70 Bar (1000 PSI)14C 140 Bar (2000 PSI)21C 210 Bar (3000 PSI)35C 350 Bar (5000 PSI)

Code Porting324 1/4″ SAE325 1/4″ BSP

Body MaterialPorting

Code Body MaterialA AluminumS Steel

Line Body

LB10

Order Bodies Separately

Code Coil TypeOmit Without CoilSP Super Coil - 19 Watts

62.7(2.47)

19.8(0.78)

33.8(1.33)

XX

VD

C X

XW

CC

X X

XX

H

MA

DE

INU

.S.A

.PAT.X

XX

XX

XX

75.7(2.98)

17.9(0.70)

Manual Override

5/8 Hex.4.1 Nm(3 lb. ft.)Torque

5/8-18 UNF

3/4 Hex.24 Nm (18 lb. ft.)Torque

12.7(0.50)

(1)

(2)

39.6(1.56)

See Super Coil1/2" I.D.Information ForTerminal Connectors

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 1/2″″″″″ I.D.*DC Only

NOTE: Requires 2G Cavity

Page 11: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV9

Proportional Relief ValveSeries AP02A2 07, 29, 35Technical Information

Specifications

Rated Flow 07 5.3 LPM (1.4 GPM)(At 70 PSI ∆∆∆∆∆P) 29 3.0 LPM (0.8 GPM)

35 2.3 LPM (0.6 GPM)

Max. Pressure At 07 70 Bar (1000 PSI) ‘SS’ CoilPort 1 100 Bar (1400 PSI) ‘SP’ Coil

29 210 Bar (3000 PSI) ‘SS’ Coil276 Bar (4000 PSI) ‘SP’ Coil

35 350 Bar (5000 PSI) ‘SP’ Coil

Hysteresis @ < 5%200 Hz PWM

Cracking 10 Bar (140 PSI)Pressure

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .08 kg (.17 lbs.)

Cavity C08-2(See BC Section for more details)

General DescriptionProportional Relief Valve. Increasing Pressure WithIncreasing Current. For additional information seeTechnical Tips on pages PV1-PV6.

Features• Analog Proportional Relief Valve regulates pressure

proportionally to the solenoid current

• Direct acting poppet design

• One piece cartridge housing ensures internalconcentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• All external parts zinc plated

Performance Curves�PWM Current Regulator Recommended

(1) (2)

(1)

(2)

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

0

5220 373

187

280

93

9

Pre

ssu

re

2618

3920

PSI Bar

1302

130

Current (%)

6020 400

80 100

Pressure vs. Input Current (%)

29 'SS' Coil

07 'SP' Coil

07 'SS' Coil

35 'SP' Coil29 'SP' Coil

Measured at coil stabilizedtemperature and nominal flow

Flow (Q)

3.8

1.0

4.5

1.2

0.8

0.2

1.5

0.4

2.3

0.6

3.0

0.8

LPM

GPM0

5.3

1.4

0

80

40

8.6

5.7

2.0

120

200 14.0

11.3160

PSI Bar

Pre

ssu

re D

rop

(P

)

35 29

07

Measured atDe-energized coil

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Pressure Drop vs. Flow

Page 12: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Relief ValveSeries AP02A2 07, 29, 35

PV10

Technical Information

FilterScreen

OverrideOption

CoilType

CoilTermination

Code Filter Screen0 None

CoilVoltage

AP02A208 Size

ProportionalRelief Valve

Style

Code Override Options0 Not Required1 Non-Detented

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style (MaximumRelief Pressure)

07 70 Bar (1000 PSI) ‘SS’ Coil100 Bar (1400 PSI) ‘SP’ Coil

29 210 Bar (3000 PSI) ‘SS’ Coil290 Bar (4000 PSI) ‘SP’ Coil

35 350 Bar (5000 PSI) ‘SP’ Coil

Code Seals / Kit. No.N Nitrile / Buna-N (Std.)

(SK30006N-1)V Fluorocarbon /

(SK30006V-1)

Seals

22.0(0.86)

66.5(2.62)

36.0(1.43)

XX

VD

C X

XW

CA

X X

XX

H

PAT.XX

XX

XX

XM

AD

EIN

U.S

.A.

3/4-16 UNF

12.7(0.50)

(2)

(1)

95.3(3.75)

27.8(1.10)

50.0(1.97)

4.1(0.16)

11.2(0.44)

Manual Override

FingerTightTorque

7/8 Hex.30 Nm (22 lb. ft.)Torque

See Super Coil5/8" I.D.Information ForTerminal Connectors

Code Port Size Body Part No.Omit Cartridge Only4P 1/4″ NPTF (B08-2-*4P)6P 3/8″ NPTF (B08-2-*6P)4T SAE-4 (B08-2-*4T)6T SAE-6 (B08-2-*6T)6B 3/8″ BSPG (B08-2-*6B)

* Add “A” for aluminum, omit for steel.

Code Body MaterialOmit Steel

A Aluminum

BodyMaterial

PortSize

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Coil TypeOmit Without CoilSS Super Coil - 18 WattsSP Super Coil - 28 Watts

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 5/8″″″″″ I.D.*DC Only

Page 13: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV11

Proportional Relief ValveSeries AP04G2YP 10C, 21C, 35CTechnical Information

Specifications

Rated Flow 95 LPM (25 GPM)(At 300 PSI ∆∆∆∆∆P)When Coil is FullyDe-Energized

Factory Set Relief 10C 103 Bar (1500 PSI)Pressure When 21C 210 Bar (3000 PSI)Coil De-Energized 35C 350 Bar (5000 PSI)Measured at45 LPM (12 GPM)

Hysteresis @ < 7%250 Hz PWM of Maximum Pressure Setting

Response Time At To Unload 10ms75% of Nominal To LoadVoltage Change 10C 45 ms(Measured To 90% 21C 60 msof Press. Change) 35C 80 ms

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .14 kg (.31 lbs.)

Cavity C10-2(See BC Section for more details)

General DescriptionProportional Relief Valve. Increasing Pressure WithIncreasing Current. For additional information seeTechnical Tips on pages PV1-PV6.

Features• Pilot operated spool-type design fits industry common

cavity (10-2)

• Relieving pressure output is proportional to DC currentinput

• Precise setting of factory preset pressure in energizedmode

• One piece cartridge housing ensures internalconcentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• All external parts zinc plated

Performance Curves�PWM Current Regulator Recommended

(1) (2)

(1)

(2)

Flow (Q)

76

20

19

5

38

10

57

15

LPM

GPM0

95

25

0

2000

1000

300

205

137

68

21

3000

5000 345

2744000

PSI Bar

Pre

ssu

re D

rop

(P

)

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Relief Performance

-35

-21

-10

Coil De-Energized

Coil Fully Energized

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

0

1000

5000 345

205

274

137

68

Pre

ssu

re 3000

4000

PSI Bar

2000

Current, Amp

.30

.15

12V

24V

.60

.300

.90

.45

1.20

.60

Pressure vs. Input Current

-35

-21

-10

Measured at coil stabilizedtemperature and nominal flow

Page 14: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Relief ValveSeries AP04G2YP 10C, 21C, 35C

PV12

Technical Information

Seals CoilType

CoilTermination

Code Seals / Kit. No.N Nitrile / Buna-N (Std.)

(SK30503N-1)V Fluorocarbon /

(SK30503V-1)

CoilVoltage

AP04G2YP10 Size

ProportionalRelief Valve

Style

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style (MaximumRelief Pressure)

10C 104 Bar (1500 PSI)21C 210 Bar (3000 PSI)35C 350 Bar (5000 PSI)

XXC* Custom PressureSetting Expressed in1/10 of Bar (Optional)

62.7(2.47)

19.8(0.78)

33.8(1.33)

7/8-14 UNF

15.8(0.62)

(1)

(2)

XX

VD

C X

XW

CC

X X

XX

H

MA

DE

INU

.S.A

.PAT.X

XX

XX

XX

97.6(3.84)

31.8(1.25)

10.0(0.40)

39.6(1.56)

5/8 Hex.4.1 Nm(3 lb. ft.)Torque

1 Hex.34 Nm (25 lb. ft.)Torque

See Super Coil1/2" I.D.Information ForTerminal Connectors

BodyMaterial

PortSize

* Add “A” for aluminum, omit for steel.† Steel body only.

Code Port Size Body Part No.Omit Cartridge Only4P 1/4″ NPTF (B10-2-*4P)6P 3/8″ NPTF (B10-2-*6P)8P 1/2″ NPTF (B10-2-*8P)6T SAE-6 (B10-2-*6T)

T6T SAE-6 (B10-2-T6T)†8T SAE-8 (B10-2-*8T)

T8T SAE-8 (B10-2-T8T)†6B 3/8″ BSPG (B10-2-*6B)

Code Body MaterialOmit Steel

A Aluminum

* Set at .94 LPM (.25 GPM)

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Coil TypeOmit Without CoilSP Super Coil - 19 Watts

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 1/2″″″″″ I.D.*DC Only

Page 15: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV13

N.O. Proportional Relief ValveSeries ERV121NTechnical Information

Performance Curves

General DescriptionNormally Open Proportional Relief Valve. For normallyclosed version, consult factory. For additional informa-tion see Technical Tips on pages PV1-PV6.

Features• On-off type solenoids

• Low hysteresis

• PWM signal preferred

• Manual override standard

• All external parts zinc plated

Specifications

Rated Flow 100 LPM (25 GPM)Valve Fully Open at 7 Bar (100 PSI) ∆P(De-energized)

Maximum Inlet 210 psi (3000 PSI)Pressure

Hysteresis 8%@ 200 Hz PWM

Cracking 10% - 25% of Input signal(Dead band)

Frequency 100 - 400 Hz (200 Hz Preferred)

Maximum Control 12VDC 24VDCCurrent 1.61A .84A

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .32 kg (0.7 lbs.)

Cavity C12-2(See BC Section for more details)

Form Tool Rougher NoneFinisher NFT12-2F

(1) (2)

(1)

(2)

1.8A1.2A

0.6A

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

0

3000 207

138

69

2000

PSI Bar

1000

Flow (Q) - 12 VDC, High Watt Coil 200 Hz

8020

205

4010

6015

LPMGPM

010025

12030

Pressure Override

Pre

ssu

re D

rop

(

P)

100 LPM(25.0 GPM)

24 LPM(6.0 GPM)

Time (MS)12 VDC, High Watt Coil 200 Hz @ 2.4 A

210 Bar (3000 PSI) Inlet Pressure

25 MS

0

3000 207

69

138

Pre

ssu

re

PSI Bar

1000

2000

Step Response

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

12 VDC, High Watt Coil 200 Hz (PWM)

1.0 1.2.2 .4 .6 .80 1.4 1.6 1.8

Pressure Gain

0

1000

3000 207

138

69

2000

PSI Bar

Pre

ssu

re D

rop

(

P)

A

20 LPM(5.0 GPM)

120 LPM(25.0 GPM)

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

0

75

100

125

150

5.2

6.9

8.6

10.3

3.5

1.7

50

PSI Bar

25

Pressure Drop vs. Flow

Pre

ssu

re D

rop

(

P)

Flow (Q)

8020

205

4010

6015

LPMGPM

010025

12030

Page 16: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

N.O. Proportional Relief ValveSeries ERV121N

PV14

Technical Information

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

SealsOverrideOption

CoilVoltage

CoilTermination

BodyMaterial

PortSize

Code Coil VoltageOmit Cartridge without CoilD012 12 VDCD024 24 VDC

Code Seals / Kit. No.Omit Nitrile / (SK12-2)

V Fluorocarbon / (SK12-2V)

Code Coil TerminationOmit Cartridge without Coil

D DINP Dual SpadeS Dual ScrewW Dual Wire

Code Override OptionsM Push Type with

Flush Rod

Code Body MaterialOmit Steel

A Aluminum

See DS Coil 5/8″″″″″ I.D. (High Watt)

ERV121N25Size 12

N.O. ProportionalRelief Valve

Code Port Size Body Part No.12P 3/4″ NTPF (B12-2-*12P)8T SAE - 8 (B12-2-*8T)

12T SAE - 12 (B12-2-*12T)* Add “A” for aluminum, omit for steel.

M

84.1(3.31)

40.1(1.58)

Ø 22.2(.87)

(1)

(2)

1 1/16-12 UN-2AThread

40.6(1.60)

See DS Coil 5/8" I.D.Information ForTerminal Connectors

31.8(1.25)

124.2(4.89)

4.1 Nm(3 lb. ft.)Torque

1-1/4" Hex.29 Nm

(21 lb. ft.)Torque

Page 17: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV15

N.O. Proportional Relief ValveSeries ERV161NTechnical Information

Performance Curves

General DescriptionNormally Open Proportional Relief Valve. For normallyclosed version, consult factory. For additional informa-tion see Technical Tips on pages PV1-PV6.

Features• On-off type solenoids

• Low hysteresis

• PWM signal preferred

• Manual override standard

• All external parts zinc plated

Specifications

Rated Flow 150 LPM (40 GPM)Valve Fully Open at 7 Bar (100 PSI) ∆P(De-energized)

Maximum Inlet 210 psi (3000 PSI)Pressure

Hysteresis 8%@ 200 Hz PWM

Cracking 10% - 25% of Input signal(Dead band)

Frequency 100 - 400 Hz (200 Hz Preferred)

Maximum Control 12VDC 24VDCCurrent 1.61A .84A

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .39 kg (0.86 lbs.)

Cavity C16-2(See BC Section for more details)

Form Tool Rougher NoneFinisher NFT16-2F

(1) (2)

(1)

(2)

1.8A1.2A

0.6A

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

0

3000 207

138

69

2000

PSI Bar

1000

Flow (Q) - 12 VDC, High Watt Coil 200 Hz

16040

4010

8020

12030

LPMGPM

020050

24060

Pressure Override

Pre

ssu

re D

rop

(

P)

160 LPM(40 GPM)

20 LPM(5.0 GPM)

Time (MS)12 VDC, High Watt Coil 200 Hz @ 2.4 A

210 Bar (3000 PSI) Inlet Pressure

35 MS

0

3000 207

69

138

Pre

ssu

re

PSI Bar

1000

2000

Step Response

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

0

1000

3000 207

138

69

2000

PSI Bar

12 VDC, High Watt Coil, 200 Hz (PWM)

1.2.4.2A .6 .8 1.00

1.4 1.6 1.8

Pressure Gain

Pre

ssu

re D

rop

(

P) 160 LPM

(40 GPM)

20 LPM(5.0 GPM)

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

0

75

100

125

150

5.2

6.9

8.6

10.3

3.5

1.7

50

PSI Bar

25

Pressure Drop vs. Flow

Pre

ssu

re D

rop

(

P)

Flow (Q)

16040

4010

8020

12030

LPMGPM

020050

24060

Page 18: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

N.O. Proportional Relief ValveSeries ERV161N

PV16

Technical Information

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

SealsOverrideOption

CoilVoltage

CoilTermination

BodyMaterial

PortSize

Code Coil VoltageOmit Cartridge without CoilD012 12 VDCD024 24 VDC

Code Seals / Kit. No.Omit Nitrile / (SK16-2)

V Fluorocarbon / (SK16-2V)

Code Coil TerminationOmit Cartridge without Coil

D DINP Dual SpadeS Dual ScrewW Dual Wire

Code Override OptionsM Push Type with

Flush Rod

Code Body MaterialOmit Steel

A Aluminum

See DS Coil 5/8″″″″″ I.D. (High Watt)

ERV161N40Size 16

N.O. ProportionalRelief Valve

Code Port Size Body Part No.12P 3/4″ NTPF (B16-2-*12P)16P 1″ NTPF (B16-2-*16P)8T SAE - 8 (B16-2-*8T)

12T SAE - 12 (B16-2-*12T)16T SAE - 16 (B16-2-*16T)12B 3/4″ BSPG (B16-2-12B)†16B 1″ BSPG (B16-2-*16B)

* Add “A” for aluminum, omit for steel.† Steel bodies only.

M

40.6(1.60)

See DS Coil 5/8" I.D.Information ForTerminal Connectors

44.5(1.75)

Ø 28.5(1.12)

1-5/16 - 12 UN-2AThread

(2)

(1)

84.5(3.33)

31.8(1.25)

128.9(5.08)

4.1 Nm(3 lb. ft.)Torque

1-1/2" Hex.54 Nm

(40 lb. ft.)Torque

Page 19: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV17

Proportional Relief ValveSeries AP01B2YR 07A, 14A, 21ATechnical Information

Specifications

Rated Flow 07A 5.3 LPM (1.4 GPM)(At 70 PSI ∆∆∆∆∆P) 14A 3.4 LPM (0.9 GPM)

21A 3.0 LPM (0.8 GPM)

Factory Set Relief 07A 70 Bar (1000 PSI)Pressure When 14A 140 Bar (2000 PSI)De-Energized 21A 235 Bar (3400 PSI)(±5% -Std.±2% - LowVariation)

Hysteresis @ < 10%200 Hz PWM

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .09 kg (.19 lbs.)

Cavity 2G(See BC Section for more details)

General DescriptionProportional Relief Valve. Decreasing Pressure WithIncreasing Current. For additional information seeTechnical Tips on pages PV1-PV6.

Features• Analog Proportional Relief Valve regulates pressure

proportionally to the input solenoid current

• Direct acting poppet design

• One piece cartridge housing ensures internalconcentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• All external parts zinc plated

Performance Curves�PWM Current Regulator Recommended

(1) (2)(1)

(2)

-21A

-14A

-07A

Flow (Q)

2.84

.75

.95

.25

1.89

.50

LPM

GPM0

3.78

1.00

0

1000

137

68

2000

4000 274

2053000

PSI Bar

Rel

ief

Pre

ssu

re

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Relief Performance

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

0

4000 274

137

205

68

Pre

ssu

re

2000

3000

PSI Bar

1000

Input Current (%)

6020 400

80 100

Pressure vs. Input Current

Measured at coil stabilizedtemperature and nominal flow

Page 20: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Relief ValveSeries AP01B2YR 07A, 14A, 21A

PV18

Technical Information

FactorySet ReliefPressure

Seals CoilType

CoilTermination

Code Seals / Kit. No.N Nitrile / Buna-N (Std.)

(SK30129N-1)V Fluorocarbon /

(SK30129V-1)E Ethylene Propylene

CoilVoltage

AP01B2YR08 Size

ProportionalRelief Valve

Style

Code Factory Set ReliefPressure Variation

Omit ±15% Std.L ±2% Low Variation

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style (MaximumRelief Pressure)

07A 70 Bar (1000 PSI)14A 140 Bar (2000 PSI)21A 235 Bar (3400 PSI)

Code Porting324 1/4″ SAE325 1/4″ BSP

Body MaterialPorting

Code Body MaterialA AluminumS Steel

Line Body

LB10

Order Bodies Separately

22.0(0.86)

66.5(2.62)

36.0(1.43)

XX

VD

C X

XW

CA

X X

XX

H

PAT.XX

XX

XX

XM

AD

EIN

U.S

.A.

5/8-18 UNF

12.7(0.50)

(2)

(1)

84.0(3.32)

26.0(1.02)

50.0(1.97)

25.4 Dia(1.00)Finger TightTorque

3/4 Hex.15 Nm (11 lb. ft.)Torque

See Super Coil5/8" I.D.Information ForTerminal Connectors

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Coil TypeOmit Without CoilSP Super Coil - 28 Watts

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 5/8″″″″″ I.D.*DC Only

NOTE: Requires 2G Cavity

Page 21: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV19

Proportional Relief ValveSeries AP02B2YR 07A, 14A, 21ATechnical Information

Specifications

Rated Flow 07A 5.3 LPM (1.4 GPM)(At 70 PSI ∆∆∆∆∆P) 14A 3.4 LPM (0.9 GPM)

21A 3.0 LPM (0.8 GPM)

Factory Set Relief 07A 70 Bar (1000 PSI)Pressure When 14A 140 Bar (2000 PSI)De-Energized 21A 235 Bar (3400 PSI)(±5% -Std.±2% - LowVariation)

Hysteresis @ < 10%200 Hz PWM

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .09 kg (.19 lbs.)

Cavity C08-2(See BC Section for more details)

General DescriptionProportional Relief Valve. Decreasing Pressure WithIncreasing Current. For additional information seeTechnical Tips on pages PV1-PV6.

Features• Analog Proportional Relief Valve regulates pressure

proportionally to the input solenoid current

• Direct acting poppet design

• One piece cartridge housing ensures internalconcentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• All external parts zinc plated

Performance Curves�PWM Current Regulator Recommended

(1) (2)

-21A

-14A

-07A

Flow (Q)

2.84

.75

.95

.25

1.89

.50

LPM

GPM0

3.78

1.00

0

1000

137

68

2000

4000 274

2053000

PSI Bar

Rel

ief

Pre

ssu

re

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Relief Performance

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

0

4000 274

137

205

68

Pre

ssu

re

2000

3000

PSI Bar

1000

Input Current (%)

6020 400

80 100

Pressure vs. Input Current

Measured at coil stabilizedtemperature and nominal flow

(1)

(2)

Page 22: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Relief ValveSeries AP02B2YR 07A, 14A, 21A

PV20

Technical Information

FactorySet ReliefPressure

Seals CoilType

CoilTermination

Code Seals / Kit. No.N Nitrile / Buna-N (Std.)

(SK30129N-1)V Fluorocarbon /

(SK30129V-1)E Ethylene Propylene

CoilVoltage

AP02B2YR08 Size

ProportionalRelief Valve

Style

Code Factory Set ReliefPressure Variation

Omit ±15% Std.L ±2% Low Variation

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style (MaximumRelief Pressure)

07A 70 Bar (1000 PSI)14A 140 Bar (2000 PSI)21A 235 Bar (3400 PSI)

BodyMaterial

PortSize

Code Port Size Body Part No.Omit Cartridge Only4P 1/4″ NPTF (B08-2-*4P)6P 3/8″ NPTF (B08-2-*6P)4T SAE-4 (B08-2-*4T)6T SAE-6 (B08-2-*6T)6B 3/8″ BSPG (B08-2-*6B)

* Add “A” for aluminum, omit for steel.

Code Body MaterialOmit Steel

A Aluminum

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Coil TypeOmit Without CoilSP Super Coil - 28 Watts

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 5/8″″″″″ I.D.*DC Only

22.0(0.86)

66.5(2.62)

36.0(1.43)

XX

VD

C X

XW

CA

X X

XX

H

PAT.XX

XX

XX

XM

AD

EIN

U.S

.A.

3/4 Hex.15 Nm (11 lb. ft.)Torque

(2)

(1)

93.3(3.67)

34.2(1.35)

50.0(1.97)

25.4 Dia(1.00)Finger TightTorque

3/4-16 UNF

See Super Coil5/8" I.D.Information ForTerminal Connectors

Page 23: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV21

Proportional Relief ValveSeries AP04G2YR 10C, 21C, 35CTechnical Information

Specifications

Rated Flow 95 LPM (25 GPM)(At 300 PSI ∆∆∆∆∆P)When Coil is FullyEnergized

Factory Set Relief 10C 103 Bar (1500 PSI)Pressure When 21C 210 Bar (3000 PSI)Coil De-Energized 35C 350 Bar (5000 PSI)Measured at45 LPM (12 GPM)

Hysteresis @ < 7%250 Hz PWM of Maximum Pressure Setting

Response Time At To Unload 45ms75% of Nominal To Load 25msVoltage Change(Measured To 90%of Press. Change)

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .14 kg (.30 lbs.)

Cavity C10-2(See BC Section for more details)

General DescriptionProportional Relief Valve. Decreasing Pressure WithIncreasing Current. For additional information seeTechnical Tips on pages PV1-PV6.

Features• Pilot operated spool-type design

• Precise setting of factory preset pressure in de-energizedmode

• One piece cartridge housing ensures internalconcentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• All external parts zinc plated

Performance Curves�PWM Current Regulator Recommended

(1) (2)

(1)

(2)

Flow (Q)

76

20

19

5

38

10

57

15

LPM

GPM0

95

25

0

2000

1000

300

205

137

68

21

3000

5000 345

2744000

PSI Bar

Rel

ief

Pre

ssu

re

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Relief Performance

-35

-21

-10

Coil Fully Energized

Coil De-Energized

-35

-21

-10

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

0

1000

5000 345

205

274

137

68

Pre

ssu

re 3000

4000

PSI Bar

2000

Input Current (%)

19 380

57 75

Pressure vs. Input Current

Page 24: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Relief ValveSeries AP04G2YR 10C, 21C, 35C

PV22

Technical Information

Seals CoilType

CoilTermination

Code Seals / Kit. No.N Nitrile / Buna-N (Std.)

(SK30503N-1)V Fluorocarbon /

(SK30503V-1)

CoilVoltage

AP04G2YR10 Size

ProportionalRelief Valve

Style

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style (MaximumRelief Pressure)

10C 104 Bar (1500 PSI)21C 210 Bar (3000 PSI)35C 350 Bar (5000 PSI)XXC Custom Pressure

Setting Expressed in1/10 of Bar (Optional)

62.7(2.47)

19.8(0.78)

33.8(1.33)

7/8-14 UNF

15.8(0.62)

(1)

(2)

XX

VD

C X

XW

CC

X X

XX

H

MA

DE

INU

.S.A

.PAT.X

XX

XX

XX

89.7(3.53)

31.8(1.25)

10.0(0.40)

39.6(1.56)

3/4 Hex.4.1 Nm(3 lb. ft.)Torque

1 Hex.34 Nm (25 lb. ft.)Torque

See Super Coil1/2" I.D.Information ForTerminal Connectors

BodyMaterial

PortSize

* Add “A” for aluminum, omit for steel.† Steel body only.

Code Port Size Body Part No.Omit Cartridge Only4P 1/4″ NPTF (B10-2-*4P)6P 3/8″ NPTF (B10-2-*6P)8P 1/2″ NPTF (B10-2-*8P)6T SAE-6 (B10-2-*6T)

T6T SAE-6 (B10-2-T6T)†8T SAE-8 (B10-2-*8T)

T8T SAE-8 (B10-2-T8T)†6B 3/8″ BSPG (B10-2-*6B)

Code Body MaterialOmit Steel

A Aluminum

* Set at .94 LPM (.25 GPM)

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Coil TypeOmit Without CoilSP Super Coil - 19 Watts

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 1/2″″″″″ I.D.*DC Only

Page 25: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV23

Proportional Pressure Reducing ValveSeries GP0130Technical Information

Specifications

Rated Flow 1.9 LPM (0.5 GPM)(At 70 PSI ∆∆∆∆∆P)

Max. Regulated StandardPressure @ 75% 17 Bar (250 PSI)Current High Pressure

22 Bar (320 PSI)

Max. Input Press. 210 Bar (3000 PSI)At Port 1

Max. Tank Press. 30 Bar (440 PSI)

Max. Drainage 5 cc/min. When De-EnergizedFlow In Regulating 200 cc/min. In Regulating ZoneZone At 68 Bar (1000 PSI) Input Pressure

Hysteresis @ 2%200 Hz PWM

Dead End t on = 30 msResponse Time t off = 10 ms

At Step Signal 0 To 75%of Nominal Voltage

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .08 kg (.17 lbs.)

Cavity 54-1(See BC Section for more details)

General Description3 Way, 2 Position, Proportional Pressure ReducingValve. Bottom Cylinder Port. For additional informationsee Technical Tips on pages PV1-PV6.

Features• Designed for pilot control of directional valves

• Low Hysteresis

• One piece cartridge housing ensures internalconcentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• All external parts zinc plated

Performance Curves�PWM Current Regulator Recommended

0

Pre

ssu

re

100

500 34.0

20.5

27.4

13.6

6.8

300

400

PSI Bar

200

AMP

.2

.1

12V

24V

.4

.2

.6

.3

.8

.4

1.0

.50

1.2

.6

1.4

.7

1.6

.8

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Pressure @ Port 1 vs. Input Current

With 'SP' Coil @ 120 Hz PWM

0

Pre

ssu

re

100

400 27.4

13.6

20.5

6.8

200

300

PSI Bar

AMP

.2

.1

12V

24V

.4

.2

.6

.3

.8

.40

1.0

.5

1.2

.6

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Pressure @ Port 1 vs. Input Current

With 'SS' Coil @ 120 Hz PWM

Flow (Q)

2.9

.75

.95

.25

1.9

.50

LPM

GPM0

3.8

1.0

0

200

100

13.6

6.8

300 20.5PSI Bar

Pre

ssu

re D

rop

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Pressure Drop vs. Flow

2 to 1Energized

1 to 3De-Eenergized

ReducingPressure

(1)

Inlet(2)

Tank(3)

(3) (2)

(1)

Page 26: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Pressure Reducing ValveSeries GP0130

PV24

Technical Information

FilterScreen

OverrideOption

CoilType

CoilTermination

Code Filter ScreenOmit Not Required

F 60 Mesh Screen onInlet Port

CoilVoltage

GP0108 Size

ProportionalValve

Style

Code Override OptionOmit If No M.O.

1 Manual Override

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style30 Standard (‘SS’ Coil)30 High Pressure

(‘SP’ Coil)

Code Porting591 1/4″ SAE

Body MaterialPorting

Code Body MaterialA AluminumS Steel

Line Body

LB10

Order Bodies Separately

30

Code Seals / Kit No.N Nitrile / Buna-N (Std.)

(SK30122N-1)V Fluorocarbon /

(SK30122V-1)

Seals

62.7(2.47)

19.8(0.78)

33.8(1.33)

ManualOverride

M18X1.5

11.9(0.47)

(1)

(2)

(3)

XX

VD

C X

XW

CC

X X

XX

H

MA

DE

INU

.S.A

.PAT.X

XX

XX

XX

85.5(3.36)

27.8(1.09)

5.6(0.22)

39.6(1.56)

9.70(0.38)

12.4(0.49)

FingerTightTorque

13/16 Hex.27 Nm (20 lb. ft.)Torque

See Super Coil1/2" I.D.Information ForTerminal Connectors

Code Coil TypeOmit Without CoilSS Super Coil - 14 WattsSP Super Coil - 19 Watts

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 1/2″″″″″ I.D.*DC Only

NOTE: Requires 54-1 Cavity

Page 27: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV25

Proportional Pressure Reducing ValveSeries GTP0234Technical Information

Specifications

Rated Flow 19 LPM (5 GPM)(At 70 PSI ∆∆∆∆∆P)

Max. Regulated 02 8 Bar (120 PSI) ‘SS’ CoilPressure @ 75% 10 Bar (150 PSI) ‘SP’ CoilCurrent 03 17 Bar (240 PSI) ‘SS’ Coil

21 Bar (300 PSI) ‘SP’ Coil05 33 Bar (480 PSI) ‘SS’ Coil

41 Bar (600 PSI) ‘SP’ Coil09 50 Bar (720 PSI) ‘SS’ Coil

62 Bar (900 PSI) ‘SP’ Coil18 100 Bar (1440 PSI) ‘SS’ Coil

124 Bar (1800 PSI) ‘SP’ Coil

Max. Input Press. 210 Bar (3000 PSI)At Port 3

Max. Drainage 100 cc/min. When De-EnergizedFlow In Regulating 750 cc/min. In Regulating ZoneZone At 21 Bar (300 PSI) Input Pressure

Hysteresis @ 3.5%100 Hz PWM

Dead End 10 ms At Step SignalResponse Time 0 To 75% of Nominal Voltage

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .08 kg (.17 lbs.)

Cavity C08-3(See BC Section for more details)

General Description3 Way, 2 Position, Proportional Pressure ReducingValve. Side Cylinder Port. For additional informationsee Technical Tips on pages PV1-PV6.

Features• Minimal Hysteresis

• One piece cartridge housing ensures internalconcentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• Nonmagnetic spool and housing assembly

• All external parts zinc plated

Performance Curves�PWM Current Regulator Recommended

(1) (3)

(2)

Tank(1)

ReducingPressure

(2)

Inlet(3)

2 to 1

3 to 2

Flow (Q)

15.2

4

3.8

1

7.6

2

11.4

3

LPM

GPM0

18.9

5

0

100

150

50

7.0

10.5

3.5

200 14.0PSI Bar

Pre

ssu

re D

rop

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Pressure Drop vs. Flow

0

Co

ntr

ol P

ress

ure

100

600 41.4

20.7

27.4

34.5

13.8

6.9

300

400

500

PSI Bar

200

Current Amps

0.1

0.2

24V

12V

0.2

0.4

0.3

0.6

0.4

0.80

0.5

1.0

0.6

1.2

0.7

1.4

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Pressure @ Port 2 vs. Input Current

GTP0234 06

GTP0234 03

GTP0234 02

With 'SP' Coil @ 100 Hz PWM

Page 28: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Pressure Reducing ValveSeries GTP0234

PV26

Technical Information

FilterScreen

OverrideOption

CoilType

CoilTermination

Code Filter Screen1 60 Mesh Screen on

Inlet Port

CoilVoltage

GTP023408 Size

ProportionalValve

Style

Code Override Option0 Not Required5 Detented M.O.

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style (MaximumRegulated Pressure)

02 8 Bar (120 PSI) ‘SS’ Coil10 Bar (150 PSI) ‘SP’ Coil

03 17 Bar (240 PSI) ‘SS’ Coil21 Bar (300 PSI) ‘SP’ Coil

05 33 Bar (480 PSI) ‘SS’ Coil41 Bar (600 PSI) ‘SP’ Coil

09 50 Bar (720 PSI) ‘SS’ Coil62 Bar (900 PSI) ‘SP’ Coil

18 100 Bar (1440 PSI) ‘SS’ Coil124 Bar (1800 PSI) ‘SP’ Coil

Code Seals / Kit No.N Nitrile / Buna-N (Std.)

(SK30081N-1)V Fluorocarbon /

(SK30081V-1)

Seals

1

62.7(2.47)

19.8(0.78)

33.8(1.33)

Manual Override(Infinite Control)

3/4-16 UNF

12.7(0.50)

(1)

(2)

(3)

XX

VD

C X

XW

CC

X X

XX

H

MA

DE

INU

.S.A

.PAT.X

XX

XX

XX

93.75(3.69)

40.21(1.58)

5.59(0.22)

39.6(1.56)

13.21(0.52)

3/4 Hex.4.1 Nm(3 lb. ft.)Torque

7/8 Hex.27 Nm (20 lb. ft.)Torque

See Super Coil1/2" I.D.Information ForTerminal Connectors

PortSize

BodyMaterial

* Add “A” for aluminum, omit for steel.

Code Port Size Body Part No.Omit Cartridge Only4P 1/4″ NPTF (B08-3-*4P)4T SAE-4 (B08-3-*4T)6T SAE-6 (B08-3-*6T)6B 3/8″ BSPG (B08-3-*6B)

Code Body MaterialOmit Steel

A Aluminum

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 1/2″″″″″ I.D.*DC Only

Code Coil TypeOmit Without CoilSS Super Coil - 14 WattsSP Super Coil - 19 Watts

Page 29: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV27

Proportional Pressure Reducing ValveSeries GTP0434Technical Information

Specifications

Rated Flow 30 LPM (8 GPM)(At 70 PSI ∆∆∆∆∆P)

Max. Regulated 02 12 Bar (170 PSI) ‘SS’ CoilPressure @ 75% 14 Bar (200 PSI) ‘SP’ CoilCurrent 03 19 Bar (280 PSI) ‘SS’ Coil

24 Bar (350 PSI) ‘SP’ Coil05 28 Bar (400 PSI) ‘SS’ Coil

35 Bar (500 PSI) ‘SP’ Coil09 52 Bar (750 PSI) ‘SS’ Coil

62 Bar (900 PSI) ‘SP’ Coil

Max. Input Press. 210 Bar (3000 PSI)At Port 3

Max. Drainage 25 cc/min. When De-EnergizedFlow In Regulating 800 cc/min. In Regulating ZoneZone At 21 Bar (300 PSI) Input Pressure

Hysteresis @ 3.5%200 Hz PWM

Dead End 40 ms At Step SignalResponse Time 0 To 75% of Nominal Voltage

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .13 kg (.28 lbs.)

Cavity 3X(See BC Section for more details)

General Description3 Way, 2 Position, Proportional Pressure ReducingValve. Side Cylinder Port. For additional informationsee Technical Tips on pages PV1-PV6.

Features• Minimal Hysteresis

• One piece cartridge housing ensures internalconcentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• Nonmagnetic spool and housing assembly

• All external parts zinc plated

Performance Curves�PWM Current Regulator Recommended

(1) (3)

(2)

Tank(1)

ReducingPressure

(2)

Inlet(3)

2 to 13 to 2

Flow (Q)

30.4

8

7.6

2

15.2

4

22.7

6

LPM

GPM0

37.8

10

0

100

150

50

7.0

10.5

3.5Pre

ssu

re D

rop

200 14.0PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Pressure Drop vs. Flow

0

Co

ntr

ol P

ress

ure

200

1000 69.0

41.4

55.2

27.6

13.8

600

800

PSI Bar

400

Current Amps

0.13

0.25

24V

12V

0.25

0.50

0.38

0.75

0.50

1.000

0.63

1.25

0.75

1.50

0.88

1.75

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Pressure @ Port 2 vs. Input Current

With 'SP' Coil @ 100 Hz PWM GTP04 3409

GTP04 3405

GTP04 3403

GTP04 3402

Page 30: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Pressure Reducing ValveSeries GTP0434

PV28

Technical Information

FilterScreen

OverrideOption

CoilType

CoilTermination

Code Filter Screen1 60 Mesh Screen on

Inlet Port

CoilVoltage

GTP043410 Size

ProportionalValve

Style

Code Override Option0 Not Required5 Detented M.O.

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style (MaximumRegulated Pressure)

02 12 Bar (170 PSI) ‘SS’ Coil14 Bar (200 PSI) ‘SP’ Coil

03 19 Bar (280 PSI) ‘SS’ Coil24 Bar (350 PSI) ‘SP’ Coil

05 28 Bar (400 PSI) ‘SS’ Coil35 Bar (500 PSI) ‘SP’ Coil

09 52 Bar (750 PSI) ‘SS’ Coil62 Bar (900 PSI) ‘SP’ Coil

Code Porting553 1/2″ SAE554 3/8″ BSP

Body MaterialPorting

Code Body MaterialA AluminumS Steel

Line Body

LB10

Order Bodies Separately

Code Seals / Kit No.N Nitrile / Buna-N (Std.)

(SK30081N-1)V Fluorocarbon /

(SK30081V-1)

Seals

1

Contact factory for other regulatedpressure to 124 Bar (1800 PSI)

22.0(0.86)

66.5(2.62)

36.0(1.43)

XX

VD

C X

XW

CA

X X

XX

H

PAT.XX

XX

XX

XM

AD

EIN

U.S

.A.

7/8-14 UNF

17.4(0.69)

(2)

(3)

(1)

112.8(4.44)

48.87(1.92)

5.54(0.22)

50.0(1.97)

13.21(0.52)

Manual Override(Infinite Control)

3/4 Hex.4.1 Nm(3 lb. ft.)Torque

1 Hex.30 Nm (22 lb. ft.)Torque

See Super Coil5/8" I.D.Information ForTerminal Connectors

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Coil TypeOmit Without CoilSS Super Coil - 18 WattsSP Super Coil - 28 Watts

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 5/8″″″″″ I.D.*DC Only

NOTE: Requires 3X Cavity

Page 31: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV29

N.C. Proportional Flow Control ValveSeries DF122CTechnical Information

Performance Curves

General DescriptionNormally Closed Proportional Flow Control Valve.For additional information see Technical Tipson pages PV1-PV6.

Features• On-off type solenoids

• Low hysteresis

• PWM signal preferred

• Manual override standard

• All external parts zinc plated

Specifications

Rated Flow 53 LPM (14 GPM)Valve Fully Open(At 100 PSI ∆∆∆∆∆P)

Maximum Inlet 210 Bar (3000 PSI)Pressure

Hysteresis 4%@ 200 Hz PWM

Cracking 20% - 30% of Input Signal(Dead band)

Frequency 100 - 400 Hz (200 Hz Preferred)

Maximum Control 12 VDC 24VDCCurrent 2.45A 1.23A

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .32 kg (0.7 lbs.)

Cavity C12-2(See BC Section for more details)

Form Tool Rougher NoneFinisher NFT12-2F

(1)

(2)

Out(1)

In(2)

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Flow (Q)

195

3810

LPMGPM

05715

7620

Pressure Drop vs. Flow @ 100% Control Current

0

300 20.7

13.8

6.9

200

PSI Bar

100

Pre

ssu

re D

rop

(

P)

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Inlet Pressure

691000

BarPSI

01382000

2073000

Flow vs. Inlet Pressure @ 100% Control Current

0

10

30 114

76

38

20

GPM LPM

Flo

w (

Q)

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

0

15 57

19

38

Flo

w (

Q)

GPM LPM

5

10

Percent of Maximum Control Current

7525 500

100

Flow vs. Input Signal (Current)

Page 32: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

N.C. Proportional Flow Control ValveSeries DF122C

PV30

Technical Information

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Seals CoilVoltage

CoilWattage

CoilTermination

BodyMaterial

PortSize

Code Coil VoltageOmit Cartridge without CoilD012 12 VDCD024 24 VDC

Code Override OptionsOmit Push Type with

Extended Rod

Code Port Size Body Part No.12P 3/4″ NTPF (B12-2-*12P)8T SAE - 8 (B12-2-*8T)

12T SAE - 12 (B12-2-*12T)* Add “A” for aluminum, omit for steel.

Code Coil TerminationOmit Cartridge without Coil

D DINP Dual SpadeW Dual Wire

Code Coil WattageOmit Cartridge

without CoilH High Watt

Code Body MaterialOmit Steel

A Aluminum

See DS Coil 1″″″″″ I.D.

DF122C1412 Size Normally

Closed ProportionalFlow Control Valve

OverrideOptions

Code Seals / Kit. No.Omit Nitrile / (SK12-2)

V Fluorocarbon / (SK12-2V)

60.0(2.35)

(1)

(2)

48.0(1.90)

FingerTight

Torque

17(.66)

Ø 22.2(.87)

1-1/16 - 12 UNF-2AThread

See DS Coil 1" I.D.Information ForTerminal Connectors

161.0(6.33)

41.3(1.63)

56.0(2.20)

1-1/4" Hex.29 Nm (21 lb. ft.)Torque

Page 33: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV31

N.C. Proportional Needle ValveSeries DF161CTechnical Information

Performance Curves

General DescriptionNormally Closed Proportional Needle Valve. This valveis designed specifically for bleed off or unloadingcircuits. Back pressure will affect performance. Foradditional information see Technical Tips on pagesPV1-PV6.

Features• On-off type solenoids

• Low hysteresis

• PWM signal preferred

• All external parts zinc plated

Specifications

Rated Flow High Watt CoilValve Fully Open 150 LPM (40 GPM)(At 100 PSI ∆∆∆∆∆P)

Maximum Inlet 210 Bar (3000 PSI)Pressure

Leakage at 125 cc/min. (7.6 in3/min.)150 SSU (32 cSt)

Hysteresis 4%@ 200 Hz PWM

Cracking 20% - 30% of Input Signal(Dead band)

Frequency 100 - 400 Hz (200 Hz Preferred)

Maximum Control 12 VDC 24VDCCurrent High Watt 2.45A 1.23A

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .34 kg (0.75 lbs.)

Cavity C16-2(See BC Section for more details)

Form Tool Rougher NoneFinisher NFT16-2F

(1)

(2)

Inlet(2)

Outlet(1)

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

0

10

40 150

113

75

38

Flo

w (

Q)

30

GPM LPM

20

Current in Amps

2.0.5 1.0 1.5A 0 2.5 3.0

Flow vs. Input Signal (Current)

High Watt @207 Bar(3000 PSI)

High Watt @34.5 Bar(500 PSI)

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Flow (Q)

113

30

38

10

75

20

LPM

GPM0

150

40

Pressure Drop vs. Flow @ 100% Current

High Watt

0

100

400 27.6

20.7

13.8

6.9

300

PSI Bar

200

Pre

ssu

re D

rop

(P

)

Page 34: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

N.C. Proportional Needle ValveSeries DF161C

PV32

Technical Information

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Seals CoilVoltage

CoilTermination

BodyMaterial

PortSize

Code Coil VoltageOmit Cartridge without CoilD012 12 VDCD024 24 VDC

Code Seals / Kit. No.Omit Nitrile / (SK16-2)

V Fluorocarbon / (SK16-2V)

Code Port Size Body Part No.12P 3/4″ NTPF (B16-2-*12P)16P 1″ NTPF (B16-2-*16P)8T SAE - 8 (B16-2-*8T)

12T SAE - 12 (B16-2-*12T)16T SAE - 16 (B16-2-*16T)12B 3/4″ BSPG (B16-2-12B)†16B 1″ BSPG (B16-2-*16B)

* Add “A” for aluminum, omit for steel.† Steel body only.

Code Coil TerminationOmit Cartridge without Coil

D DINP Dual SpadeW Dual Wire

Code Body MaterialOmit Steel

A Aluminum

See DS Coil 1″″″″″ I.D

DF161C4016 Size Normally

Closed ProportionalFlow Control Valve

48.1(1.90)

59.8(2.35)

Outlet(1)

Inlet(2)

56.0(2.20)

44.4(1.75)

Ø 28.5(1.12)

136.8(5.38)

See DS Coil 1" I.D.Information ForTerminal Connectors

1-5/16 - 12 UN-2AThread

4.1 Nm(3 lb. ft.)Torque

1-1/2" Hex.54 Nm (40 lb. ft.)Torque

Page 35: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV33

N.C. Proportional Needle ValveSeries DF201CTechnical Information

Performance Curves

General DescriptionNormally Closed Proportional Needle Valve. This valveis designed specifically for bleed off or unloadingcircuits. Back pressure will affect performance. Foradditional information see Technical Tips on pagesPV1-PV6.

Features• On-off type solenoids

• Low hysteresis

• PWM signal preferred

• All external parts zinc plated

Specifications

Rated Flow Low Watt 180 LPM (48 GPM)Valve Fully Open High Watt 325 LPM (60 GPM)(At 100 PSI ∆∆∆∆∆P)

Maximum Inlet 210 Bar (3000 PSI)Pressure

Leakage at 125 cc/min. (7.6 in3/min.)150 SSU (32 cSt)

Hysteresis 4%@ 200 Hz PWM

Cracking 20% - 30% of Input Signal(Dead band)

Frequency 100 - 400 Hz (200 Hz Preferred)

Maximum Control 12 VDC 24VDCCurrent Low Watt 1.75A .91A

High Watt 2.45A 1.23A

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .34 kg (0.75 lbs.)

Cavity C20-2(See BC Section for more details)

Form Tool Rougher NoneFinisher NFT20-2F

Flow vs. Input Signal (Current)Hydraulic Oil 150 SSU @ 100°F (32 cSt)

0

10

20

60 227

150

189

113

38

75

Flo

w (

Q)

40

50

GPM LPM

30

Current in Amps

2.0.5 1.0 1.5A 0 2.5 3.0

High Watt @207 Bar(3000 PSI)Low Watt @

207 Bar (3000 PSI)

Low Watt @34.5 Bar (500 PSI)

High Watt @34.5 Bar (500 PSI)

Low Watt

High Watt

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Flow (Q)

189

50

38

10

113

30

151

40

76

20

LPM

GPM0

227

60

Pressure Drop vs. Flow @ 100% Current

0

100

500

400

36.2

29.0

21.7

14.5

7.2

300

PSI Bar

200

Pre

ssu

re D

rop

(P

)

(2)

(1)

Inlet(2)

Outlet(1)

Page 36: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

N.C. Proportional Needle ValveSeries DF201C

PV34

Technical Information

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Seals CoilVoltage

CoilWattage

CoilTermination

BodyMaterial

PortSize

Code Coil VoltageOmit Cartridge without CoilD012 12 VDCD024 24 VDC

Code Seals / Kit. No.Omit Nitrile / (SK20-2)

V Fluorocarbon / (SK20-2V)

Code Port Size Body Part No.20T SAE - 20 (B20-2-*20T)20B 1-1/4″ BSPG (B20-2-*20B)

* Add “A” for aluminum, omit for steel.

Code Coil TerminationOmit Cartridge without Coil

D DINP Dual SpadeW Dual Wire

Code Coil WattageOmit Cartridge

without CoilL Low WattH High Watt

Code Body MaterialOmit Steel

A Aluminum

See DS Coil 1″″″″″ I.D.

DF201C6020 Size Normally

Closed ProportionalFlow Control Valve

Inlet(2)

Outlet(1)

60.5(2.38)

48.3(1.90)

56.0(2.20)

See DS Coil 1" I.D.Information ForTerminal Connectors

142.2(5.60)

55.1(2.17)

Ø 36.8(1.45)

1 5/8-12 UN-2AThread

4.1 Nm(3 lb. ft.)Torque

1-7/8" Hex.113 Nm (83 lb. ft.)Torque

Page 37: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV35

Proportional Flow Regulator ValveSeries HP02C 21Technical Information

Specifications

Rated Flow @ Standard (‘SS’ Coil)210 Bar (3000 PSI) 2 to 1 13.3 LPM (3.5 GPM)

1 to 2 9.5 LPM (2.5 GPM)High Flow (‘SP’ Coil)2 to 1 22.8 LPM (6.0 GPM)1 to 2 15.0 LPM (4.0 GPM)

Preferable Input Port 1Port For BestHysteresis

Hysteresis @ <10%100 Hz PWM

Cracking Pressure 25% of Input Current

Variation of Flow Standard Model@ 35% of Rated Up To ±20% Of Rated FlowCurrent & Constant Model “L”∆∆∆∆∆P Maintained By ±7% Of Rated FlowPressureCompensator

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .08 kg (.17 lbs.)

Cavity 2X(See BC Section for more details)

General Description2 Way, Normally Closed, Proportional Flow RegulatorValve. Partially Pressure Compensated. For additionalinformation see Technical Tips on pages PV1-PV6.

Features• Analog Proportional Partially Pressure Compensated

Flow Regulator regulates flow proportionally to the inputsolenoid current.

• A low cost valve designed to be used in applicationswhere fine pressure compensation is not required.

• One piece cartridge housing ensures internalconcentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• Nonmagnetic spool and housing assembly

• Factory-adjusted low variation option (Model “L”) isavailable for applications where low variation of flow fromvalve to valve is essential at a given current or when anexternal pressure compensator is used.

• All external parts zinc plated

Performance Curves�PWM Current Regulator Recommended

Pressure

35

500

Bar

PSI

70

1000

105

15000

140

2000

175

2500

210

3000

0

Flo

w

15.2

22.8

7.6

4

6

2

8 30.4GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Flow Regulation (Measured at 75% of Rated Current)

2 to 1 ('SP' Coil)

1 to 2 ('SP' Coil)

2 to 1 ('SS' Coil)

1 to 2 ('SS' Coil)

Input Current (%)

8020 40 600

1000

4 15.2

2 7.6

6 22.8GPM LPM

Flo

w

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Flow vs. Input Current

2 to 1 ('SP' Coil)

1 to 2 ('SP' Coil)

2 to 1 ('SS' Coil)

1 to 2 ('SS' Coil)

(2)

(1)

(1)

(2)

Page 38: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Flow Regulator ValveSeries HP02C 21

PV36

Technical Information

FilterScreen

OverrideOption

CoilType

CoilTermination

Code Filter Screen0 Not Available

CoilVoltage

HP02C08 Size

ProportionalValve

Style

Code Override Option0 Not Required5 Detented M.O.

(Infinite Control)

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style (MaximumRegulated Flow)

21 Standard (‘SS’ Coil)13.3 LPM (3.5 GPM)

21 High Flow (‘SP’ Coil)22.8 LPM (6.0 GPM)

Code Porting513 3/8″ SAE515 1/4″ BSP

Body MaterialPorting

Code Body MaterialA AluminumS Steel

Line Body

LB10

Order Bodies Separately

Code Seals / Kit No.N Nitrile / Buna-N (Std.)

(SK30076N-1)V Fluorocarbon /

(SK30076V-1)

Seals

21Flow

Variation

Code Flow VariationOmit Standard Up to ±20%

of Rated FlowL Low Variation

(±7% of Rated Flow)

62.7(2.47)

19.8(0.78)

33.8(1.33)

Manual Override(Infinite Control)

3/4-16 UNF

15.9(0.63)

(1)

(2)

XX

VD

C X

XW

CC

X X

XX

H

MA

DE

INU

.S.A

.PAT.X

XX

XX

XX

82.04(3.23)

28.5(1.12)

5.59(0.22)

39.6(1.56)

13.21(0.52)

3/4 Hex.4.1 Nm(3 lb. ft.)Torque

7/8 Hex.20 Nm (27 lb. ft.)Torque

See Super Coil1/2" I.D.Information ForTerminal Connectors

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Coil TypeOmit Without CoilSS Super Coil - 14 WattsSP Super Coil - 19 Watts

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 1/2″″″″″ I.D.*DC Only

NOTE: Requires 2X Cavity

Page 39: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV37

Proportional Flow Regulator ValveSeries JP02C 20, 21Technical Information

Specifications

Rated Flow 20 7.5 LPM (2 GPM)Low Flow (‘SS’ Coil)

21 15 LPM (4 GPM)Standard (‘SS’ Coil)

21 23 LPM (6 GPM)High Flow (‘SP’ Coil)

Maximum Input 210 Bar (3000 PSI)Pressure At Port 2

Minimum Pressure 20 6.9 Bar (150 PSI) Low FlowDifferential 21 13.8 Bar (200 PSI) Standard

21 20.7 Bar (300 PSI) High Flow

Maximum Internal 570 cc (35 cu. in.)Leakage @ 210 Bar (3000 PSI)

Hysteresis @ <10% (Low Flow and Standard)100 Hz PWM <3% (High Flow)

Cracking Pressure 25% of Input Signal

Variation of Flow Standard Model@ 35% of Rated Up To ±20% Of Rated FlowCurrent Model “L”

±7% Of Rated Flow

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .08 kg (.17 lbs.)

Cavity C08-3(See BC Section for more details)

General Description2 Way, Normally Closed, Proportional Flow RegulatorValve. Pressure Compensated. For additional informa-tion see Technical Tips on pages PV1-PV6.

Features• One piece cartridge housing ensures internal

concentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• Nonmagnetic spool and housing assembly

• Factory-adjusted low variation option (Model “L”) isavailable for applications where low variation of flow fromvalve to valve is essential at a given current.

• All external parts zinc plated

Performance Curves�PWM Current Regulator Recommended

(3)

(2)

Port (1)Is Not Used(3)

(2)

Flow

3.8

1

LPM

GPM

7.5

2

11.4

3

15.2

40

18.9

5

22.8

6

0

Pre

ssu

re

100

13.8

20.7

6.9

200

300

PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt)Pressure Drop vs. Flow

JP02C 20('SS' Coil)

JP02C 21('SS' Coil)

JP02C 21('SP' Coil)

Measured when valve is fully open@ 75% of rated current

0

Flo

w

2

15.2

22.8

7.6

4

6

GPM LPM

Pressure

35

500

Bar

PSI

70

1000

105

1500

140

20000

175

2500

210

3000

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Flow Regulation (Measured 75% of Rated Current)

JP02C 21 ('SP' Coil)

JP02C 21 ('SS' Coil)

JP02C 20 ('SS' Coil)

Input Current (%)

8020 40 600

1000

4

2

15.2

7.6

6 22.8GPM LPM

Flo

w

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Flow vs. Input Current

JP02C 20('SS' Coil)

JP02C 21 ('SP' Coil)

JP02C 21('SS' Coil)

Page 40: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Flow Regulator ValveSeries JP02C 20, 21

PV38

Technical Information

FilterScreen

OverrideOption

CoilType

CoilTermination

Code Filter Screen0 Not Available1 60 Mesh Screen on

Port 2

CoilVoltage

JP02C08 Size

ProportionalValve

Style

Code Override Option0 Not Required5 Detented M.O.

(Infinite Control)

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style (MaximumRegulated Flow)

20 Low Flow (‘SS’ Coil)7.5 LPM (2 GPM)

21 Standard (‘SS’ Coil)15 LPM (4 GPM)

21 High Flow (‘SP’ Coil)23 LPM (6 GPM)

Code Seals / Kit No.N Nitrile / Buna-N (Std.)

(SK30105N-1)V Fluorocarbon /

(SK30105V-1)

Seals FlowVariation

Code Flow VariationOmit Standard Up to ±20%

of Rated FlowL Low Variation

(±7% of Rated Flow)

62.7(2.47)

19.8(0.78)

33.8(1.33)

Manual Override(Infinite Control)

3/4-16 UNF

14.2(0.56)

(3)

(2)

XX

VD

C X

XW

CC

X X

XX

H

MA

DE

INU

.S.A

.PAT.X

XX

XX

XX

96.04(3.78)

42.5(1.67)

5.54(0.22)

39.6(1.56)

13.21(0.52)

3/4 Hex.4.1 Nm(3 lb. ft.)Torque

7/8 Hex.27 Nm (20 lb. ft.)Torque

See Super Coil1/2" I.D.Information ForTerminal Connectors

PortSize

BodyMaterial

* Add “A” for aluminum, omit for steel.

Code Port Size Body Part No.Omit Cartridge Only4P 1/4″ NPTF (B08-3-*4P)4T SAE-4 (B08-3-*4T)6T SAE-6 (B08-3-*6T)6B 3/8″ BSPG (B08-3-*6B)

Code Body MaterialOmit Steel

A Aluminum

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 1/2″″″″″ I.D.*DC Only

Code Coil TypeOmit Without CoilSS Super Coil - 14 WattsSP Super Coil - 19 Watts

Page 41: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV39

Proportional Flow Regulator ValveSeries HP04C 21Technical Information

Specifications

Rated Flow Standard (‘SS’ Coil)2 to 1 @ 30 LPM (8 GPM)210 Bar (3000 PSI) High Flow (‘SP’ Coil)

36 LPM (9.5 GPM)

Preferable Input Port 1Port For BestHysteresis

Hysteresis @ <10%100 Hz PWM

Cracking Pressure 21% of Rated Current (Standard)17% of Rated Current (High Flow)

Variation of Flow Standard Model@ 35% of Rated Up To ±5% Of Rated FlowCurrent & Constant Model “L”∆∆∆∆∆P Maintained By ±2% Of Rated FlowPressureCompensator

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .12 kg (.26 lbs.)

Cavity C10-2(See BC Section for more details)

General Description2 Way, Normally Closed, Proportional Flow RegulatorValve. Partially Pressure Compensated. For additionalinformation see Technical Tips on pages PV1-PV6.

Features• Analog Proportional Partially Pressure Compensated

Flow Regulator regulates flow proportionally to the inputsolenoid current.

• A low cost valve designed to be used in applicationswhere fine pressure compensation is not required.

• One piece cartridge housing ensures internalconcentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• Nonmagnetic spool and housing assembly

• Factory-adjusted low variation option (Model “L”) isavailable for applications where low variation of flow fromvalve to valve is essential at a given current or when anexternal pressure compensator is used.

• All external parts zinc platedPerformance Curves�PWM Current Regulator Recommended

'SP' Coil

'SS' Coil

Input Current (%)

8020 40 600

1000

12 45.6

4

8

15.2

30.4

16 60.8GPM LPM

Flo

w

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Flow vs. Input Current

Pressure

35

500

Bar

PSI

70

1000

105

15000

140

2000

175

2500

210

3000

0

Flo

w

30.4

45.6

15.2

8

12

4

16 60.8GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Flow Regulation

2 to 1

1 to 2

Measured 75% of ratedcurrent with 'SP' Coil

(2)

(1)

(1)

(2)

Page 42: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Flow Regulator ValveSeries HP04C 21

PV40

Technical Information

FilterScreen

OverrideOption

CoilType

CoilTermination

Code Filter Screen0 Not Available

CoilVoltage

HP04C10 Size

ProportionalValve

Style

Code Override Option0 Not Required5 Detented M.O.

(Infinite Control)

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style (MaximumRegulated Flow)

21 Standard (‘SS’ Coil)30 LPM (8 GPM)

21 High Flow (‘SP’ Coil)36 LPM (9.5 GPM)

Code Seals / Kit No.N Nitrile / Buna-N (Std.)

(SK30503N-1)V Fluorocarbon /

(SK30503V-1)

Seals

21Opening

PointVariation

Code Flow VariationOmit Standard Up to ±5%

of CurrentL Low Variation

(±2% of Current Flow)

22.0(0.86)

66.5(2.62)

36.0(1.43)

XX

VD

C X

XW

CA

X X

XX

H

PAT.XX

XX

XX

XM

AD

EIN

U.S

.A.

7/8-14 UNF

15.8(0.62)

(2)

(1)

96.5(3.80)

33.3(1.31)

5.60(0.22)

50.0(1.97)

13.72(0.54)

7.88(0.31)

4.0(0.16)

Manual Override(Infinite Control)Stroke

3/4 Hex.4.1 Nm(3 lb. ft.)Torque

1 Hex.30 Nm (22 lb. ft.)Torque

See Super Coil5/8" I.D.Information ForTerminal Connectors

BodyMaterial

PortSize

* Add “A” for aluminum, omit for steel.† Steel body only.

Code Port Size Body Part No.Omit Cartridge Only4P 1/4″ NPTF (B10-2-*4P)6P 3/8″ NPTF (B10-2-*6P)8P 1/2″ NPTF (B10-2-*8P)6T SAE-6 (B10-2-*6T)

T6T SAE-6 (B10-2-T6T)†8T SAE-8 (B10-2-*8T)

T8T SAE-8 (B10-2-T8T)†6B 3/8″ BSPG (B10-2-*6B)

Code Body MaterialOmit Steel

A Aluminum

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 5/8″″″″″ I.D.*DC Only

Code Coil TypeOmit Without CoilSS Super Coil - 18 WattsSP Super Coil - 28 Watts

Page 43: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV41

Proportional Flow Regulator ValveSeries JP04C 21Technical Information

Specifications

Rated Flow 21 30 LPM (8 GPM)Standard (‘SS’ Coil)

21 36 LPM (9.5 GPM)High Flow (‘SP’ Coil)

Maximum Input 210 Bar (3000 PSI)Pressure At Port 2

Minimum Pressure 21 13.8 Bar (200 PSI) StandardDifferential 21 20.7 Bar (300 PSI) High Flow

Maximum Internal 780 cc (46 cu. in.)Leakage @ 210 Bar (3000 PSI)

Hysteresis @ 7%100 Hz PWM

Cracking Pressure 25% of Input Signal

Variation of Flow Standard Model@ 35% of Rated Up To ±20% Of Rated FlowCurrent Model “L”

±7% Of Rated Flow

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .13 kg (.28 lbs.)

Cavity 3X(See BC Section for more details)

General Description2 Way, Normally Closed, Proportional Flow RegulatorValve. Pressure Compensated. For additional informa-tion see Technical Tips on pages PV1-PV6.

Features• One piece cartridge housing ensures internal

concentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• Nonmagnetic spool and housing assembly

• Factory-adjusted low variation option (Model “L”) isavailable for applications where low variation of flow fromvalve to valve is essential at a given current.

• All external parts zinc plated

Performance Curves�PWM Current Regulator Recommended

(3)

(2)

(3)

(2)

Port (1)Is Not Used

Flow

7.6

2

LPM

GPM

15.2

4

22.7

6

30.4

80

37.8

10

45.0

12

0

Pre

ssu

re

100

13.8

20.7

6.9

200

300

PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt)Pressure Drop vs. Flow

'SS' Coil

'SP'Coil

Measured when valve is fully open@ 75% of rated current

"SS" Coil

"SP" Coil

Input Current (%)

8020 40 600

1000

8

4

30.3

15.1

12 45.4GPM LPM

Flo

w

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Flow vs. Input Signal

0

Flo

w

4

30.3

45.4

15.1

8

12

GPM LPM

Pressure

35

500

Bar

PSI

70

1000

105

1500

140

20000

175

2500

210

3000

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Flow Regulation (Measured 75% of Rated Current)

JP04C 21 ("SP" Coil)

JP04C 21 ("SS" Coil)

Page 44: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Flow Regulator ValveSeries JP04C 21

PV42

Technical Information

FilterScreen

OverrideOption

CoilType

CoilTermination

Code Filter Screen0 Not Required1 60 Mesh Screen on

Port 2

CoilVoltage

JP04C10 Size

ProportionalValve

Style

Code Override Option0 Not Required5 Detented M.O.

(Infinite Control)

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style (MaximumRegulated Flow)

21 Standard (‘SS’ Coil)30 LPM (8 GPM)

21 High Flow (‘SP’ Coil)36 LPM 9.5 GPM)

Code Porting553 1/2″ SAE554 3/8″ BSP

Body MaterialPorting

Code Body MaterialA AluminumS Steel

Line Body

LB10

Order Bodies Separately

Code Seals / Kit No.N Nitrile / Buna-N (Std.)

(SK30106N-1)V Fluorocarbon /

(SK30106V-1)

Seals FlowVariation

Code Flow VariationOmit Standard Up to ±20%

of Rated FlowL Low Variation

(±7% of Rated Flow)

21

22.0(0.86)

66.5(2.62)

36.0(1.43)

XX

VD

C X

XW

CA

X X

XX

H

PAT.XX

XX

XX

XM

AD

EIN

U.S

.A.

7/8-14 UNF

17.4(0.68)

(2)

(3)

115.7(4.55)

51.79(2.04)

5.51(0.22)

50.0(1.97)

13.21(0.52)

Manual Override(Infinite Control)

3/4 Hex.4.1 Nm(3 lb. ft.)Torque

1 Hex.30 Nm (22 lb. ft.)Torque

See Super Coil5/8" I.D.Information ForTerminal Connectors

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Coil TypeOmit Without CoilSS Super Coil - 18 WattsSP Super Coil - 28 Watts

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 5/8″″″″″ I.D.*DC Only

NOTE: Requires 3X Cavity

Page 45: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV43

Proportional Flow Regulator ValveSeries HP02P 21Technical Information

Specifications

Rated Flow @ 2 to 1 19 LPM (5 GPM)210 Bar (3000 PSI)

Preferable Input Port 1Port For BestHysteresis

Hysteresis @ <10%100 Hz PWM

Variation of Flow Standard Model@ 35% of Rated Up To ±20% Of Rated FlowCurrent & Constant Model “L”∆∆∆∆∆P Maintained By ±7% Of Rated FlowPressureCompensator

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .08 kg (.17 lbs.)

Cavity 2X(See BC Section for more details)

General Description2 Way, Normally Open, Proportional Flow RegulatorValve. Partially Pressure Compensated. For additionalinformation see Technical Tips on pages PV1-PV6.

Features• Analog Proportional Partially Pressure Compensated

Flow Regulator regulates flow proportionally to the inputsolenoid current

• The valve is designed to be used in applications wherefine pressure compensation is not required and aneconomical solution is important

• One piece cartridge housing ensures internalconcentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• Nonmagnetic spool and housing assembly

• Factory-adjusted low variation option (Model “L”) isavailable for applications where low variation of flow fromvalve to valve is essential at a given current or when anexternal pressure compensator is used.

• All external parts zinc plated Performance Curves�PWM Current Regulator Recommended

(2)

(1)

(1)

(2)

2 to 1

1 to 2

Pressure

35

500

Bar

PSI

70

1000

105

15000

140

2000

175

2500

210

3000

0

Flo

w

15.2

22.8

7.6

4

6

2

8 30.4GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Flow Regulation (Measured at De-Energized Coil)

Input Current (%)

8020 40 600

1000

4 15.2

2 7.6

6 22.8GPM LPM

Flo

w

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Flow vs. Input Current

2 to 1 OR 1 to 2

Page 46: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Flow Regulator ValveSeries HP02P 21

PV44

Technical Information

FilterScreen

OverrideOption

CoilType

CoilTermination

Code Filter Screen0 Not Available

CoilVoltage

HP02P08 Size

ProportionalValve

Style

Code Override Option0 Not Required5 Detented M.O.

(Infinite Control)

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style (MaximumRegulated Flow)

21 High Flow (‘SP’ Coil)19 LPM (5 GPM)

Code Porting513 3/8″ SAE515 1/4″ BSP

Body MaterialPorting

Code Body MaterialA AluminumS Steel

Line Body

LB10

Order Bodies Separately

Code Seals / Kit No.N Nitrile / Buna-N (Std.)

(SK30076N-1)V Fluorocarbon /

(SK30076V-1)

Seals

21Flow

Variation

Code Flow VariationOmit Standard Up to ±20%

of Rated FlowL Low Variation

(±7% of Rated Flow)

62.7(2.47)

19.8(0.78)

33.8(1.33)

Manual Override(Infinite Control)

3/4-16 UNF

15.9(0.63)

(1)

(2)

XX

VD

C X

XW

CC

X X

XX

H

MA

DE

INU

.S.A

.PAT.X

XX

XX

XX

82.04(3.23)

28.5(1.12)

5.59(0.22)

39.6(1.56)

13.21(0.52)

3/4 Hex.4.1 Nm(3 lb. ft.)Torque

7/8 Hex.27 Nm (20 lb. ft.)Torque

See Super Coil1/2" I.D.Information ForTerminal Connectors

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Coil TypeOmit Without CoilSP Super Coil - 19 Watts

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 1/2″″″″″ I.D.*DC Only

NOTE: Requires 2X Cavity

Page 47: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV45

Proportional Flow Regulator ValveSeries JP02P 20, 21Technical Information

Specifications

Rated Flow 20 9.5 LPM (2.5 GPM)Standard (‘SS’ Coil)

21 19 LPM (5 GPM)High Flow (‘SP’ Coil)

Maximum Input 210 Bar (3000 PSI)Pressure At Port 2

Minimum Pressure 20 6.9 Bar (150 PSI) StandardDifferential 21 20.7 Bar (300 PSI) High Flow

Maximum Internal 570 cc (35 cu. in.)Leakage @ 210 Bar (3000 PSI)

Hysteresis @ <3%100 Hz PWM

Variation of Flow Standard Model@ 35% of Rated Up To ±20% Of Rated FlowCurrent Model “L”

±7% Of Rated Flow

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .08 kg (.17 lbs.)

Cavity C08-3(See BC Section for more details)

General Description2 Way, Normally Open, Proportional Flow RegulatorValve. Pressure Compensated. For additional informa-tion see Technical Tips on pages PV1-PV6.

Features• One piece cartridge housing ensures internal

concentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• Nonmagnetic spool and housing assembly

• Factory-adjusted low variation option (Model “L”) isavailable for applications where low variation of flow fromvalve to valve is essential at a given current.

• All external parts zinc plated

Performance Curves�PWM Current Regulator Recommended

(3)

(2)

(3)

(2)

Port (1)Is Not Used

JP02P 20

JP02P 21

0

Flo

w

2

15.2

22.8

7.6

4

6

GPM LPM

Pressure

35

500

Bar

PSI

70

1000

105

1500

140

20000

175

2500

210

3000

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Flow Regulation (Measured 75% of Rated Current)

JP02P 20

JP02P 21

Input Current (%)

8020 40 600

1000

4

2

15.2

7.6

6 22.8GPM LPM

Flo

w

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Flow vs. Input Current

Flow

3.8

1

LPM

GPM

7.5

2

11.4

3

15.2

40

18.9

5

22.8

6

0

Pre

ssu

re

100

13.8

20.7

6.9

200

300

PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt)Pressure Drop vs. Flow

JP02P 20

Measured atde-energized coil

JP02P 21

Page 48: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Flow Regulator ValveSeries JP02P 20, 21

PV46

Technical Information

FilterScreen

OverrideOption

CoilType

CoilTermination

Code Filter Screen0 Not Required1 60 Mesh Screen on

Port 2

CoilVoltage

JP02P08 Size

ProportionalValve

Style

Code Override Option0 Not Required5 Detented M.O.

(Infinite Control)

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style (MaximumRegulated Flow)

20 Standard (‘SS’ Coil)9.5 LPM (2.5 GPM)

21 High Flow (‘SP’ Coil)19 LPM (5 GPM)

Code Seals / Kit No.N Nitrile / Buna-N (Std.)

(SK30105N-1)V Fluorocarbon /

(SK30105V-1)

Seals FlowVariation

Code Flow VariationOmit Standard Up to ±20%

of Rated FlowL Low Variation

(±7% of Rated Flow)

62.7(2.47)

19.8(0.78)

33.8(1.33)

Manual Override(Infinite Control)

3/4-16 UNF

14.2(0.56)

(3)

(2)

XX

VD

C X

XW

CC

X X

XX

H

MA

DE

INU

.S.A

.PAT.X

XX

XX

XX

96.04(3.78)

42.5(1.67)

5.54(0.22)

39.6(1.56)

13.21(0.52)

3/4 Hex.4.1 Nm(3 lb. ft.)Torque

7/8 Hex.27 Nm (20 lb. ft.)Torque

See Super Coil1/2" I.D.Information ForTerminal Connectors

PortSize

BodyMaterial

* Add “A” for aluminum, omit for steel.

Code Port Size Body Part No.Omit Cartridge Only4P 1/4″ NPTF (B08-3-*4P)4T SAE-4 (B08-3-*4T)6T SAE-6 (B08-3-*6T)6B 3/8″ BSPG (B08-3-*6B)

Code Body MaterialOmit Steel

A Aluminum

Code Coil TypeOmit Without CoilSS Super Coil - 14 WattsSP Super Coil - 19 Watts

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 1/2″″″″″ I.D.*DC Only

Page 49: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV47

Proportional Flow Regulator ValveSeries HP04P 21Technical Information

Specifications

Rated Flow @ 23 LPM (6 GPM)210 Bar (3000 PSI)

Hysteresis @ <10%100 Hz PWM

Closing Point 65% of Rated Current

Variation of Standard ModelClosing Point Up To ±5% Of Rated Current

Model “L”±2% Of Rated Current

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .12 kg (.26 lbs.)

Cavity C10-2(See BC Section for more details)

General Description2 Way, Normally Open, Proportional Flow RegulatorValve. Partially Pressure Compensated. For additionalinformation see Technical Tips on pages PV1-PV6.

Features• Analog Proportional Partially Pressure Compensated

Flow Regulator regulates flow proportionally to the inputsolenoid current

• The valve is designed to be used in applications wherefine pressure compensation is not required and anexonomical solution is important

• One piece cartridge housing ensures internalconcentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• Nonmagnetic spool and housing assembly

• Factory-adjusted low variation option (Model “L”) isavailable for applications where low variation of flow fromvalve to valve is essential at a given current or when anexternal pressure compensator is used.

• All external parts zinc plated Performance Curves�PWM Current Regulator Recommended

(2)

(1)

(1)

(2)

Input Current (%)

8020 40 600

1000

4

8

15.2

30.4

12 45.5GPM LPM

Flo

w

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Flow vs. Input Current

Pressure Differential

42

600

Bar

PSI

84

12000

126

1800

168

2400

210

3000

0

Flo

w

30.4

15.2

8

4

12 45.5GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Flow Regulation

Measured at de-energized coil

Page 50: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Flow Regulator ValveSeries HP04P 21

PV48

Technical Information

FilterScreen

OverrideOption

CoilType

CoilTermination

Code Filter Screen0 Not Available

CoilVoltage

HP04P10 Size

ProportionalValve

Style

Code Override Option0 Not Required5 Detented M.O.

(Infinite Control)

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style (MaximumRegulated Flow)

21 High Flow (‘SP’ Coil)30 LPM (8 GPM)

Code Seals / Kit No.N Nitrile / Buna-N (Std.)

(SK30503N-1)V Fluorocarbon /

(SK30503V-1)

Seals

21Opening

PointVariation

Code Flow VariationOmit Standard Up to ±5%

of Current FlowL Low Variation

(±2% of Current Flow)

22.0(0.86)

66.5(2.62)

36.0(1.43)

XX

VD

C X

XW

CA

X X

XX

H

PAT.XX

XX

XX

XM

AD

EIN

U.S

.A.

7/8-14 UNF

15.8(0.62)

(2)

(1)

97.3(3.83)

5.59(0.22)

50.0(1.97)

13.21(0.52)

8.38(0.33)

Manual Override(Infinite Control)

3/4 Hex.4.1 Nm(3 lb. ft.)Torque

1 Hex.30 Nm (22 lb. ft.)Torque

See Super Coil5/8" I.D.Information ForTerminal Connectors

BodyMaterial

PortSize

* Add “A” for aluminum, omit for steel.† Steel body only.

Code Port Size Body Part No.Omit Cartridge Only4P 1/4″ NPTF (B10-2-*4P)6P 3/8″ NPTF (B10-2-*6P)8P 1/2″ NPTF (B10-2-*8P)6T SAE-6 (B10-2-*6T)

T6T SAE-6 (B10-2-T6T)†8T SAE-8 (B10-2-*8T)

T8T SAE-8 (B10-2-T8T)†6B 3/8″ BSPG (B10-2-*6B)

Code Body MaterialOmit Steel

A Aluminum

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Coil TypeOmit Without CoilSP Super Coil - 28 Watts

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 5/8″″″″″ I.D.*DC Only

Page 51: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV49

Proportional Flow Regulator ValveSeries JP04P 21Technical Information

Specifications

Rated Flow 36 LPM (9.5 GPM)High Flow (‘SP’ Coil)

Maximum Input 210 Bar (3000 PSI)Pressure At Port 2

Minimum Pressure 14 Bar (200 PSI)Differential

Maximum Internal 780 cc (46 cu. in.)Leakage @ 210 Bar (3000 PSI)

Hysteresis @ 7%100 Hz PWM

Variation of Flow Standard Model@ 35% of Rated Up To ±20% Of Rated FlowCurrent Model “L”

±7% Of Rated Flow

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .13 kg (.28 lbs.)

Cavity 3X(See BC Section for more details)

General Description2 Way, Normally Open, Proportional Flow RegulatorValve. Pressure Compensated. For additional informa-tion see Technical Tips on pages PV1-PV6.

Features• One piece cartridge housing ensures internal

concentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• Nonmagnetic spool and housing assembly

• Factory-adjusted low variation option (Model “L”) isavailable for applications where low variation of flow fromvalve to valve is essential at a given current.

• All external parts zinc plated

Performance Curves�PWM Current Regulator Recommended

(3)

(2)

(3)

(2)

Port (1)Is Not Used

0

Flo

w

3

22.7

34.2

11.4

6

9

GPM LPM

Pressure

35

500

Bar

PSI

70

1000

105

1500

140

20000

175

2500

210

3000

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Flow Regulation

Flow

7.6

2

LPM

GPM

15.2

4

22.7

6

30.4

80

37.8

10

45.0

12

0

Pre

ssu

re

100

13.8

20.7

6.9

200

300

PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt)Pressure Drop vs. Flow

Measured atde-energized coil

Input Current (%)

8020 40 600

1000

6

3

22.7

11.4

9 34.2GPM LPM

Flo

w

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Flow vs. Input Current

Page 52: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Flow Regulator ValveSeries JP04P 21

PV50

Technical Information

FilterScreen

OverrideOption

CoilType

CoilTermination

Code Filter Screen0 Not Required1 60 Mesh Screen on

Port 2

CoilVoltage

JP04P10 Size

ProportionalValve

Style

Code Override Option0 Not Required5 Detented M.O.

(Infinite Control)

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style (MaximumRegulated Flow)

21 High Flow (‘SP’ Coil)36 LPM 9.5 GPM)

Code Porting553 1/2″ SAE554 3/8″ BSP

Body MaterialPorting

Code Body MaterialA AluminumS Steel

Line Body

LB10

Order Bodies Separately

Code Seals / Kit No.N Nitrile / Buna-N (Std.)

(SK30106N-1)V Fluorocarbon /

(SK30106V-1)

Seals FlowVariation

Code Flow VariationOmit Standard Up to ±20%

of Rated FlowL Low Variation

(±7% of Rated Flow)

21

22.0(0.86)

66.5(2.62)

36.0(1.43)

XX

VD

C X

XW

CA

X X

XX

H

PAT.XX

XX

XX

XM

AD

EIN

U.S

.A.

7/8-14 UNF

17.4(0.68)

(2)

(3)

115.7(4.55)

51.79(2.04)

5.51(0.22)

50.0(1.97)

13.21(0.52)

Manual Override(Infinite Control)

3/4 Hex.4.1 Nm(3 lb. ft.)Torque

1 Hex.30 Nm (22 lb. ft.)Torque

See Super Coil5/8" I.D.Information ForTerminal Connectors

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Coil TypeOmit Without CoilSP Super Coil - 28 Watts

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 5/8″″″″″ I.D.*DC Only

NOTE: Requires 3X Cavity

Page 53: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV51

N.O. Proportional Flow Control ValveSeries DF122NTechnical Information

Performance Curves

General DescriptionNormally Open Proportional Flow Control Valve.For additional information see Technical Tipson pages PV1-PV6.

Features• On-off type solenoids

• Low hysteresis

• PWM signal preferred

• Manual override standard

• All external parts zinc plated

Specifications

Rated Flow 53 LPM (14 GPM)Valve Fully Open(At 100 PSI ∆∆∆∆∆P)

Maximum Inlet 210 Bar (3000 PSI)Pressure

Hysteresis 4%@ 200 Hz PWM

Frequency 100 - 400 Hz (200 Hz Preferred)

Maximum Control 12 VDC 24VDCCurrent 2.45A 1.23A

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .32 kg (0.7 lbs.)

Cavity C12-2(See BC Section for more details)

Form Tool Rougher NoneFinisher NFT12-2F

Note: 4.1 Bar (60psi) is required at port 1 to fully return Manualoverride.

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Flow (Q)

195

3810

LPMGPM

05715

7620

Pressure Drop vs. Flow @ No Current

0

300 20.7

13.8

6.9

200

PSI Bar

100

Pre

ssu

re D

rop

(

P)

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Inlet Pressure

691000

BarPSI

01382000

2073000

Flow vs. Inlet Pressure @ No Current

0

10

30 114

76

38

20

GPM LPM

Flo

w (

Q)

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

0

15 57

19

38

Flo

w (

Q)

GPM LPM

5

10

Percent of Maximum Control Current

7525 500

100

Flow vs. Input Signal (Current)

(1)

(2)

In(1)

Out(2)

Page 54: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

N.O. Proportional Flow Control ValveSeries DF122N

PV52

Technical Information

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Seals CoilVoltage

CoilWattage

CoilTermination

BodyMaterial

PortSize

Code Coil VoltageOmit Cartridge without CoilD012 12 VDCD024 24 VDC

Code Seals / Kit. No.Omit Nitrile / (SK12-2)

V Fluorocarbon / (SK12-2V)

Code Port Size Body Part No.12P 3/4″ NTPF (B12-2-*12P)8T SAE - 8 (B12-2-*8T)

12T SAE - 12 (B12-2-*12T)* Add “A” for aluminum, omit for steel.

Code Coil TerminationOmit Cartridge without Coil

D DINP Dual SpadeW Dual Wire

Code Coil WattageOmit Cartridge

without CoilH High Watt

Code Body MaterialOmit Steel

A Aluminum

See DS Coil 1″″″″″ I.D.

DF122N1412 Size NormallyOpen ProportionalFlow Control Valve

OverrideOptions

Code Override OptionsOmit Push Type with

Extenden Rod

60.0(2.35)

(1)

(2)

48.0(1.90)

FingerTight

Torque

17(.66)

Ø 22.2(.87)

1-1/16 - 12 UNF-2AThread

See DS Coil 1" I.D.Information ForTerminal Connectors

161.0(6.33)

41.3(1.63)

56.0(2.20)

1-1/4" Hex.29 Nm (21 lb. ft.)Torque

Page 55: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV53

Proportional 3-Way Flow Control ValveSeries DF083NTechnical Information

Performance Curves

General DescriptionProportional 3-Way Flow Control Valve. Valve can beused as normally open, or normally closed. Foradditional information see Technical Tips on pagesPV1-PV6.

Features• On-off type solenoids

• Low hysteresis

• PWM signal preferred

• Manual override standard

• All external parts zinc plated

Specifications

Rated Flow 11 LPM (3 GPM)Valve Fully Open(At 100 PSI ∆∆∆∆∆P)

Maximum Inlet 210 Bar (3000 PSI)Pressure

Hysteresis 4%@ 200 Hz PWM

Cracking 20% - 30% of Input Signal(Dead band)

Frequency 100 - 400 Hz (200 Hz Preferred)

Maximum Control 12 VDC 24VDCCurrent 1.61A .84A

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .31 kg (0.69 lbs.)

Cavity C08-3(See BC Section for more details)

Form Tool Rougher NFT08-3RFinisher NFT08-3F

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

0

1.0

4.0 15.1

11.3

7.6

3.8

Flo

w (

Q)

3.0

GPM LPM

2.0

Input Current - 12 VDC, 30W Coil, 200 Hz

1.5.5 1.0A 0 2.0 2.5

Flow Gain

1 to 2 3 to 1

Flow (Q)

7.6

2

3.8

1

LPM

GPM0

11.4

3

15.1

4

Hydraulic Oil 150 SSU @ 100°F (32 cSt)Pressure Drop vs. Flow

0

25

50

8.6

10.3

5.2

6.9

1.7

3.5

125

150PSI Bar

75

100

Pre

ssu

re D

rop

(P

)

(3)

(1)

(2)

(1)

(3)

(2)

Page 56: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional 3-Way Flow Control ValveSeries DF083N

PV54

Technical Information

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

SealsOverrideOption

CoilVoltage

CoilWattage

CoilTermination

BodyMaterial

PortSize

Code Coil VoltageOmit Cartridge without CoilD012 12 VDCD024 24 VDC

Code Seals / Kit. No.Omit Nitrile / (SK08-3N)

V Fluorocarbon / (SK08-3V)

Code Port Size Body Part No.4P 1/4″ NPTF (B08-3-*4P)4T SAE - 4 (B08-3-*4T)6T SAE - 6 (B08-3-*6T)6B 3/8″ BSPG (B08-3-*6B)

* Add “A” for aluminum, omit for steel.

Code Coil TerminationOmit Cartridge without Coil

D DINP Dual SpadeS Dual ScrewW Dual WireCode Coil Wattage

Omit Cartridgewithout Coil

H High Watt

Code Override OptionsM Push Type with

Flush Rod

Code Body MaterialOmit Steel

A Aluminum

See DS Coil 5/8″″″″″ I.D.

DF083N308 Size

Proportional 3-WayFlow Control Valve

M

31.6(1.24)

118(4.64)

40.6(1.60)

39.5(1.56)

(1)

(2)

(3)

44.7(1.76)

See DS Coil 5/8" I.D.Information ForTerminal Connectors

3/4-16 UNF-2AThread

4.1 Nm(3 lb. ft.)Torque

7/8" Hex.20 Nm (15 lb. ft.)Torque

Page 57: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV55

Proportional Flow Regulator ValveSeries JP04C 31Technical Information

Specifications

Rated Inlet Flow 60 LPM (16 GPM)

Rated Regulated 31 26 LPM (7 GPM)Flow Standard (‘SS’ Coil)

31 30 LPM (8 GPM)High Flow (‘SP’ Coil)

Maximum Input 210 Bar (3000 PSI)Pressure At Port 3

Minimum Pressure 31 13.8 Bar (200 PSI) StandardDifferential 31 20.7 Bar (300 PSI) High Flow

Maximum Internal 780 cc (46 cu. in.)Leakage @ 210 Bar (3000 PSI)

Hysteresis @ 7%100 Hz PWM

Opening Point Standard21% of Nominal AmperageHigh Flow17% of Nominal Amperage

Variation of Standard ModelOpening Point Up To ±50% Of Amperage

Model “L”±20% Of Amperage

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .14 kg (.31 lbs.)

Cavity 3X(See BC Section for more details)

General Description3 Way, Normally Closed, Proportional Flow RegulatorValve. Pressure Compensated. For additional informa-tion see Technical Tips on pages PV1-PV6.

Features• Analog proportional pressure compensated flow control

valve regulates flow proportionally to the input solenoidcurrent

• One piece cartridge housing ensures internalconcentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• Nonmagnetic spool and housing assembly

• Factory-adjusted low variation option (Model “L”) isavailable for applications where low variation of flow fromvalve to valve is essential at a given current.

• All external parts zinc plated Performance Curves�PWM Current Regulator Recommended

(4) (2)

(3)

(1)

*

*Always connect Port (1) toPort (4) through .039" orifice.

Not Used(1)

Bypass(2)

Inlet(3)

Reg.(4)

*

0

Pre

ssu

re

100

13.9

20.7

6.9

200

300PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Pressure Drop vs. Flow at Coil Fully Energized

7.5

2

LPM

GPM

15.2

4

22.8

6

30.4

80

37.8

10

45.5

12Flow

Input Current (%)

25 50 750

100

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

0

2

22.8

38.0

7.6

6

10GPM LPM

Flo

w

Regulated Flow vs. Input Current Stabilized

Pressure

140

2000

140

2000

210

3000

Bar

PSI

70

1000

0

0

70

1000

210

3000

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Regulated Load HigherThan By-Pass

By-Pass Load HigherThan Regulated0

6

8

2

4

22.7

30.4

7.6

15.2

10 38.0GPM LPM

Flo

wPressure Compensation of Regulated Flow (Port 4)

Page 58: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Flow Regulator ValveSeries JP04C 31

PV56

Technical Information

FilterScreen

OverrideOption

CoilType

CoilTermination

Code Filter Screen0 Not Available

CoilVoltage

JP04C10 Size

ProportionalValve

Style

Code Override Option0 Not Required5 Detented M.O.

(Infinite Control)

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style (MaximumRegulated Flow)

31 Standard (‘SS’ Coil)26 LPM (7 GPM)

31 High Flow (‘SP’ Coil)30 LPM (8 GPM)

Code Porting562 1/2″ SAE563 3/8″ BSP

Body MaterialPorting

Code Body MaterialA AluminumS Steel

Line Body

LB10

Order Bodies Separately

Code Seals / Kit No.N Nitrile / Buna-N (Std.)

(SK30082N-1)V Fluorocarbon /

(SK30082V-1)

Seals FlowVariation

Code Flow VariationOmit Standard Up to ±50%

of Opening AmpsL Low Variation (±20%

of Opening Amps)

31

66.5(2.62) 22.0

(0.86)

36.0(1.43)

XX

VD

C X

XW

CA

X X

XX

H

PAT.XX

XX

XX

XM

AD

EIN

U.S.A

.

15.9(0.62)

(1)

Ext. Pilot

Reg. (4)

In (3)

Byp. (2)

7/8-14 UNF

Manual Override(Infinite Control)

13.21(0.52)

8.38(0.33)

50.0(1.97)

133.4(5.25) 5.59

(0.22)

3/4 Hex.4.1 Nm(3 lb. ft.)Torque

1 Hex.30 Nm (22 lb. ft.)Torque

See Super Coil5/8" I.D.Information ForTerminal Connectors

Code Coil TypeOmit Without CoilSS Super Coil - 18 WattsSP Super Coil - 28 Watts

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 5/8″″″″″ I.D.*DC Only

NOTE: Requires 3X Cavity

Page 59: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV57

Proportional Directional Control ValveSeries GP02 51, 51L, 52Technical Information

Specifications

Operating Ports 2, 3 and 4Pressure 350 Bar (5000 PSI)

Port 1210 Bar (3000 PSI)

Hysteresis @ <6%100 Hz PWM

Cracking Flow 25% to 30% of Input Signal

Variation of Flow ±15% @ 75% of Nominal Currentand Constant ∆P Maintained byPressure Compensator

Port to Port 10 cu. in. @ 3000 PSILeakage

Step Response On 50 msTime at 75% of Off 40 msAmps

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .15 kg (.34 lbs.)

Cavity C08-4

General Description4 Way, 3 Position, Proportional Directional ControlValve. Closed Center Spool. For additional informationsee Technical Tips on pages PV1-PV6.

Features• One piece cartridge housing ensures internal

concentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• All external parts zinc plated

Performance Curves�PWM Current Regulator Recommended

Typical PerformanceRATED FLOW AT 75%

OF NOMINAL CURRENTLPM - (GPM)

‘b’SOLENOID

PULLP to B, A to T

‘a’SOLENOID

PUSHP to A, B to T

PUSH PULL

Compensator∆∆∆∆∆P

Bar (PSI)

SPOOLTYPE AND

FLOW

51LLow Flow

51Standard

52High Flow

SUPERCOIL TYPE

5.3 - (1.4) 5.3 - (1.4) SP SP 10 (150)

3.4 - (0.9) 3.4 - (0.9) SS SS 5 (75)

13.3 - (3.5) 17 - (4.5) SP SP 15 (220)

11.4 - (3.0) 15.2 - (4.0) SS SS 15 (220)

21 - (5.5) 17 - (4.5) SP SP 20 (290)

17.4 - (4.5) 13 - (3.5) SP SP 15 (220)

(3)

(2)

(4)

(1)

(1)

(2)

(3)

(4)

0

3

1

11.4

3.8

5 19.0GPM LPM

Flo

w

0CurrentAmps

.15

.3025%

.30

.6050%

.30

.6050%

.45

.9075%

.45

.9075%

.601.20

100%

.601.20

100%

24V12V

.15

.3025%

51L With 5 Bar, 75 PSI Compensator51 With 15 Bar, 220 PSI Compensator and SS Coil

51L

51

51L

51

PULL 'b'PUSH 'a'

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Pressure

70

1000

Bar

PSI

140

2000

210

30000

280

4000

350

5000

0

Flo

w

1

7.6

11.4

15.2

3.8

2

3

4GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Flow vs. Load

P to A, B to T

P to B, A to T P to B, A to T

P to A, B to T

Pressure Not CompensatedCompensated With Hydrostat P =� 250 psi

0

Flo

w

2

15.2

22.8

7.6

4

6GPM LPM

52 With 20 Bar, 290 PSI Compensator and SP Coil

0CurrentAmps

.20

.4025%

.20

.4025%

.40

.8050%

.40

.8050%

.601.2075%

.601.2075%

.801.60

100%

.801.60

100%

24V12V

52 52

PUSH 'a' PULL 'b'

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Page 60: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Directional Control ValveSeries GP02 51, 51L, 52

PV58

Technical Information

SealsOverrideOption

CoilType

CoilTermination

CoilVoltage

GP0208 Size

ProportionalValve

Style

Code Override OptionOmit Not Required

1 Manual Override2 Detented M.O.

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style - Closed Center(Flow Pressure andPerformance)

51 Standard51L Low Flow52 High Flow

Code Seals / Kit No.N Nitrile / Buna-N (Std.)

(SK30078N-1)V Fluorocarbon /

(SK30078V-1)

M.O. Option(Unlatch andPull or Push)

LatchingSleeve

27.0(1.08)

6.0(.25) Stroke

62.7(2.47)

19.8(0.78)

33.8(1.33)

12.7(0.50)

53.0(2.10)

(1)

(2)

(3)

(4)

39.6(1.56)

39.6(1.56)

94.0(3.71)

XX

VD

C X

XW

CC

X X

XX

H

MA

DE

INU

.S.A

.PAT.X

XX

XX

XX

b

a

3/4 Hex.4.1 Nm(3 lb. ft.)Torque

7/8 Hex.30 Nm (22 lb. ft.)Torque

See Super Coil1/2" I.D.Information ForTerminal Connectors

SampleApplication Circuit(Closed Center)

3(P)

2(A)

1(T)

4(B)

13

2

32

1

Compensator(R04H3)

PortSize

BodyMaterial

* Add “A” for aluminum, omit for steel.

Code Port Size Body Part No.Omit Cartridge Only4T SAE-4 (B08-4-*4T)6T SAE-6 (B08-4-*6T)6B 3/8″ BSPG (B08-4-*6B)

Code Body MaterialOmit Steel

A Aluminum

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Coil TypeOmit Without CoilSS Super Coil - 14 WattsSP Super Coil - 19 Watts

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 1/2″″″″″ I.D.*DC Only

Page 61: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV59

Proportional Directional Control ValveSeries GP04 51, 51HL, 51HLHTechnical Information

Specifications

Operating Ports 2, 3 and 4Pressure 350 Bar (5000 PSI)

Port 1210 Bar (3000 PSI)

Hysteresis @ <6%100 Hz PWM

Cracking Flow 25% to 30% of Input Signal

Variation of Flow ±15% @ 75% of Nominal Currentand Constant ∆P Maintained byPressure Compensator

Port to Port 10 cu. in. @ 3000 PSILeakage

Step Response On 50 msTime at 75% of Off 40 msAmps

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscostiy of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .28 kg (.57 lbs.)

Cavity C10-4

General Description4 Way, 3 Position, Proportional Directional ControlValve. Closed Center Spool. For additional informationsee Technical Tips on pages PV1-PV6.

Features• One piece cartridge housing ensures internal

concentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• All external parts zinc plated

Performance Curves�PWM Current Regulator Recommended

RATED FLOW AT 75%OF NOMINAL CURRENT

LPM - (GPM)

‘b’SOLENOID

PULLP to B, A to T

‘a’SOLENOID

PUSHP to A, B to T

PUSH PULL

Compensator∆∆∆∆∆P

Bar (PSI)

SPOOLTYPE AND

FLOW

51

51HLHigh - LowStandard

51HLHHigh - LowHigh Flow

SUPERCOIL TYPE

32 - (8.5) 44 - (11.5) SP SP 15 (220)

28 - (7.5) 38 - (10.0) SS SS 15 (220)

15 - (4.0) 30 - (8.0) SP SP 10 (150)

13 - (3.5) 26 - (7.0) SS SS 10 (150)

19 - (5.0) 38 - (10.0) SP SP 15 (220)

15 - (4.0) 34 - (9.0) SS SS 15 (220)

Typical Performance

(3)

(2)

(4)

(1)

(1)

(2)

(3)

(4)

0CurrentAmps

.19

.3825%

.38

.7550%

.38

.7550%

.571.1375%

.571.1375%

.751.50

100%

.751.50

100%

24V12V

.19

.3825%

51 and 51HLH With 15 Bar, 220 PSI Compensatorand SS Coil

0

2

4

6

8

7.6

15.2

22.8

30.4

10 38.0GPM LPM

Flo

w

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

5151HLH

51

51HLH

PULL 'b'

PUSH 'a'

0CurrentAmps

.30

.6025%

.30

.6025%

.601.2050%

.601.2050%

.901.8075%

.901.8075%

1.202.40

100%

1.202.40

100%

24V12V

51 With 15 Bar, 220 PSI Compensator and SP Coil

0

Flo

w

30.4

38.0

15.2

7.6

22.8

8

10

4

2

6

12 45.5GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt)

51

51PUSH 'a' PULL 'b'

Page 62: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Directional Control ValveSeries GP04 51, 51HL, 51HLH

PV60

Technical Information

SealsOverrideOption

CoilType

CoilTermination

CoilVoltage

GP0410 Size

ProportionalValve

Style

Code Override OptionOmit Not Required

1 Manual Override2 Detented M.O.

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style - Closed Center(Flow Pressure andPerformance)

51 Standard51HL High - Low

51HLH High - Low, High Flow

Code Seals / Kit No.N Nitrile / Buna-N (Std.)

(SK30506N-1)V Fluorocarbon /

(SK30506V-1)

M.O. Option(Unlatch andPull or Push)

LatchingSleeve

28.0(1.10)

4.8(.19) Stroke

36.0(1.43)

22.0(0.86)

66.5(2.62)

50.0(1.97)

50.0(1.97)

15.9(0.63)

63.0(2.47)

(1)

(2)

(3)

(4)

118.0(4.66)

b

a

XX

VD

C X

XW

CA

X X

XX

H

PAT.XX

XX

XX

XM

AD

EIN

U.S

.A.

3/4 Hex.4.1 Nm(3 lb. ft.)Torque

1 Hex.34 Nm (25 lb. ft.)Torque

See Super Coil5/8" I.D.Information ForTerminal Connectors

SampleApplication Circuit(Closed Center)

3(P)

2(A)

1(T)

4(B)

13

2

32

1

Compensator(R06H3)

PortSize

BodyMaterial

* Add “A” for aluminum, omit for steel.† Steel body only.

Code Port Size Body Part No.Omit Cartridge Only6P 3/8″ NPTF (B10-4-*6P)6T SAE-6 (B10-4-*6T)8T SAE-8 (B10-4-*8T)6B 3/8″ BSPG (B10-4-6B)†

Code Body MaterialOmit Steel

A Aluminum

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Coil TypeOmit Without CoilSS Super Coil - 18 WattsSP Super Coil - 28 Watts

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 5/8″″″″″ I.D.*DC Only

Page 63: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV61

Proportional Directional Control ValveSeries GP02 53, 53L, 54Technical Information

Specifications

Operating Ports 2, 3 and 4Pressure 350 Bar (5000 PSI)

Port 1210 Bar (3000 PSI)

Hysteresis @ <6%100 Hz PWM

Cracking Flow 25% to 30% of Input Signal

Variation of Flow ±15% @ 75% of Nominal Currentand Constant ∆P Maintained byPressure Compensator

Port to Port 10 cu. in. @ 3000 PSILeakage

Step Response On 50 msTime at 75% of Off 40 msAmps

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility/ lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .15 kg (.34 lbs.)

Cavity C08-4

General Description4 Way, 3 Position, Proportional Directional ControlValve. Floating Center Spool. For additional informationsee Technical Tips on pages PV1-PV6.

Features• One piece cartridge housing ensures internal

concentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• All external parts zinc plated

Performance Curves�PWM Current Regulator Recommended

Typical PerformanceRATED FLOW AT 75%

OF NOMINAL CURRENTLPM - (GPM)

‘b’SOLENOID

PULLP to B, A to T

‘a’SOLENOID

PUSHP to A, B to T

PUSH PULL

Compensator∆∆∆∆∆P

Bar (PSI)

SPOOLTYPE AND

FLOW

53LLow Flow

53Standard

54High Flow

SUPERCOIL TYPE

5.3 - (1.4) 5 - (1.4) SP SP 10 (150)

4 - (1.0) 4 - (1.0) SS SS 5 (75)

14 - (3.8) 15 - (4.0) SP SP 10 (150)

9 - (2.5) 10 - (2.7) SS SS 5 (75)

17 - (4.5) 19 - (5.0) SP SP 20 (290)

15 - (4.0) 15 - (4.0) SS SS 15 (220)

(3)

(2)

(4)

(1)

(1)

(2)

(3)

(4)

53L

53

53L

53

PULL 'b'PUSH 'a'

0

3

1

11.4

3.8

5 19.0GPM LPM

Flo

w

0CurrentAmps

.15

.3025%

.30

.6050%

.30

.6050%

.45

.9075%

.45

.9075%

.601.20

100%

.601.20

100%

24V12V

.15

.3025%

53 and 53L With 5 Bar, 75 PSICompensator and SS Coil

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

54 54

PUSH 'a' PULL 'b'

0

Flo

w

2

15.2

22.8

7.6

4

6GPM LPM

54 With 20 Bar, 290 PSI Compensator and SP Coil

0CurrentAmps

.20

.4025%

.20

.4025%

.40

.8050%

.40

.8050%

.601.2075%

.601.2075%

.801.60

100%

.801.60

100%

24V12V

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Pressure

70

1000

Bar

PSI

140

2000

210

30000

280

4000

350

5000

0

Flo

w

1

7.6

11.4

15.2

3.8

2

3

4GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Flow vs. Load

P to A, B to T

P to B, A to T P to B, A to T

P to A, B to T

Pressure Not CompensatedCompensated With Hydrostat P =� 250 psi

Page 64: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Directional Control ValveSeries GP02 53, 53L, 54

PV62

Technical Information

SealsOverrideOption

CoilType

CoilTermination

CoilVoltage

GP0208 Size

ProportionalValve

Style

Code Override OptionOmit Not Required

1 Manual Override2 Detented M.O.

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style - Floating Center(Flow Pressure andPerformance)

53 Standard53L Low Flow54 High Flow

Code Seals / Kit No.N Nitrile / Buna-N (Std.)

(SK30078N-1)V Fluorocarbon /

(SK30078V-1)

M.O. Option(Unlatch andPull or Push)

LatchingSleeve

27.0(1.08)

6.0(.25) Stroke

62.7(2.47)

19.8(0.78)

33.8(1.33)

12.7(0.50)

53.0(2.10)

(1)

(2)

(3)

(4)

39.6(1.56)

39.6(1.56)

94.0(3.71)

XX

VD

C X

XW

CC

X X

XX

H

MA

DE

INU

.S.A

.PAT.X

XX

XX

XX

b

a

3/4 Hex.4.1 Nm(3 lb. ft.)Torque

7/8 Hex.30 Nm (22 lb. ft.)Torque

See Super Coil1/2" I.D.Information ForTerminal Connectors

SampleApplication Circuit(Floating Center)

3(P)

2(A)

1(T)

4(B)

13

2

32

1

Compensator(R04H3)

PortSize

BodyMaterial

* Add “A” for aluminum, omit for steel.

Code Port Size Body Part No.Omit Cartridge Only4T SAE-4 (B08-4-*4T)6T SAE-6 (B08-4-*6T)6B 3/8″ BSPG (B08-4-*6B)

Code Body MaterialOmit Steel

A Aluminum

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Coil TypeOmit Without CoilSS Super Coil - 14 WattsSP Super Coil - 19 Watts

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 1/2″″″″″ I.D.*DC Only

Page 65: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

CheckValves

ShuttleValves

Load/Motor

ControlsFlow

ControlsPressureControls

LogicElem

entsDirectional

ControlsM

anualValves

SolenoidValves

ProportionalValves

Coils &Electronics

Bodies &Cavities

TechnicalData

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

PV63

Proportional Directional Control ValveSeries GP04 53, 53HL, 53HLHTechnical Information

Specifications

Operating Ports 2, 3 and 4 -Pressure 350 Bar (5000 PSI)

Port 1 - 210 Bar (3000 PSI)

Hysteresis @ <6% @ 100 Hz PWM

Cracking Flow 25% to 30% of Input Signal

Variation of Flow ±15% @ 75% of Nominal Currentand Constant ∆P Maintained byPressure Compensator

Port to Port 10 cu. in. @ 3000 PSILeakage

Step Response On 50 msTime at 75% of Off 40 msAmps

Cartridge Material All parts steel. All operatingparts hardened steel.

Operating Temp. -40°C to +93.3°C (Nitrile)Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)

Fluid Mineral-based or synthetic withCompatibility lubricating properties at viscositiesViscosity of 45 to 2000 SSU (6 to 420 cSt)

Filtration ISO Code 16/13,SAE Class 4 or better

Approx. Weight .28 kg (.57 lbs.)

Cavity C10-4

General Description4 Way, 3 Position, Proportional Directional ControlValve. Floating Center Spool. For additional informationsee Technical Tips on pages PV1-PV6.

Features• One piece cartridge housing ensures internal

concentricity

• Coil: Waterproof, hermetically sealed, requires noO’Rings; Symmetrical coil can be reversed withoutaffecting performance.

• All external parts zinc plated

Performance Curves�PWM Current Regulator Recommended

RATED FLOW AT 75%OF NOMINAL CURRENT

LPM - (GPM)

‘b’SOLENOID

PULLP to B, A to T

‘a’SOLENOID

PUSHP to A, B to T

PUSH PULL

Compensator∆∆∆∆∆P

Bar (PSI)

SPOOLTYPE AND

FLOW

53

53HLHigh - LowStandard

53HLHHigh - LowHigh Flow

SUPERCOIL TYPE

45 - (12.0) 45 - (12.0) SP SP 15 (220)

38 - (10.0) 32 - (8.5) SS SS 15 (220)

32 - (8.5) 36 - (9.5) SP SP 10 (150)

26 - (7.0) 34 - (9.0) SS SS 10 (150)

13 - (3.5) 30 - (8.0) SP SP 10 (150)

- - - - -

15 - (4.0) 38 - (10.0) SP SP 15 (220)

- - - - -

Typical Performance

(1)

(2)

(3)

(4)

(3)

(2)

(4)

(1)

5353

PUSH 'a' PULL 'b'

0CurrentAmps

.19

.3825%

.38

.7550%

.38

.7550%

.571.1375%

.571.1375%

.751.50

100%

.751.50

100%

24V12V

.19

.3825%

53 With 15 Bar, 220 PSI Compensator and SS Coil

0

2

4

6

8

7.6

15.2

22.8

30.4

10 38.0GPM LPM

Flo

w

Hydraulic Oil 150 SSU @ 100°F (32 cSt)

5353

PULL 'b'PUSH 'a'

0CurrentAmps

.30

.6025%

.30

.6025%

.601.2050%

.601.2050%

.901.8075%

.901.8075%

1.202.40

100%

1.202.40

100%

24V12V

53 With 15 Bar, 220 PSI Compensator and SP Coil

0

Flo

w

30.4

38.0

15.2

7.6

22.8

8

10

4

2

6

12 45.5GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Page 66: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

Catalog HY15-3501/US

Parker Hannifin CorporationHydraulic Cartridge Systems

Chec

kVa

lves

Shut

tleVa

lves

Load

/Mot

orCo

ntro

lsFl

owCo

ntro

lsPr

essu

reCo

ntro

lsLo

gic

Elem

ents

Dire

ctio

nal

Cont

rols

Man

ual

Valv

esPr

opor

tiona

lVa

lves

Coils

&El

ectro

nics

Tech

nica

lDa

ta

SH

CV

LM

FC

PC

LE

DC

MV

SV

PV

CE

BC

TD

Bodi

es &

Cavi

ties

Sole

noid

Valv

es

Proportional Directional Control ValveSeries GP04 53, 53HL, 53HLH

PV64

Technical Information

SealsOverrideOption

CoilType

CoilTermination

CoilVoltage

GP0410 Size

ProportionalValve

Style

Code Override OptionOmit Not Required

1 Manual Override2 Detented M.O.

Dimensions Millimeters (Inches)

Ordering Information

THIRD-ANGLEPROJECTION

Code Style - Floating Center(Flow Pressure andPerformance)

53 Standard53HL High - Low

53HLH High - Low, High Flow

Code Seals / Kit No.N Nitrile / Buna-N (Std.)

(SK30506N-1)V Fluorocarbon /

(SK30506V-1)

M.O. Option(Unlatch andPull or Push)

LatchingSleeve

28.0(1.10)

4.8(.19) Stroke

36.0(1.43)

22.0(0.86)

66.5(2.62)

50.0(1.97)

50.0(1.97)

15.9(0.63)

63.0(2.47)

(1)

(2)

(3)

(4)

118.0(4.66)

b

a

XX

VD

C X

XW

CA

X X

XX

H

PAT.XX

XX

XX

XM

AD

EIN

U.S

.A.

3/4 Hex.4.1 Nm(3 lb. ft.)Torque

1 Hex.34 Nm (25 lb. ft.)Torque

See Super Coil5/8" I.D.Information ForTerminal Connectors

SampleApplication Circuit(Floating Center)

3(P)

2(A)

1(T)

4(B)

13

2

32

1

Compensator(R06H3)

PortSize

BodyMaterial

* Add “A” for aluminum, omit for steel.† Steel body only.

Code Port Size Body Part No.Omit Cartridge Only6P 3/8″ NPTF (B10-4-*6P)6T SAE-6 (B10-4-*6T)8T SAE-8 (B10-4-*8T)6B 3/8″ BSPG (B10-4-6B)†

Code Body MaterialOmit Steel

A Aluminum

Code Coil VoltageOmit Without CoilD012 12 VDCD024 24 VDC

Code Coil TypeOmit Without CoilSS Super Coil - 18 WattsSP Super Coil - 28 Watts

Code Coil TerminationOmit Without Coil

D DIN Plug FaceA Amp Jr. Timer*L Dual Lead Wire*H Molded Deutsch*

See Super Coil 5/8″″″″″ I.D.*DC Only

Page 67: Catalog HY15-3501/US Contents Proportional Valves ·  · 2010-07-27Catalog HY15-3501/US Contents Proportional Valves Parker Hannifin Corporation Hydraulic Cartridge Systems Check

BLANKPAGE