cat-cmp cable gland
TRANSCRIPT
-
8/17/2019 Cat-CMP Cable Gland
1/64
-
8/17/2019 Cat-CMP Cable Gland
2/64
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
cmp
ATEX 95
• Cable Gland & Accessories• Meeting The Atex Hazardous
Area Directive
TRITON CDS• Cable Gland & Accessories• Cable Gland Selection Programme• Unique Design Features
ontheweb
-
8/17/2019 Cat-CMP Cable Gland
3/64
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
As a leading manufacturer of metallic cable glands and
electrical mining products for global applications CMP
Products is committed to ensuring it remains the
number one choice in its markets.
CMP will retain status as the number one supplier by
continually striving to achieve standards of excellence
in our company through the continuous improvement
of our processes and functions. It is only by achieving
this that CMP will continue to offer unrivaled customer
service throughout the globe.
In order to reach these goals CMP Products has set
itself the following targets for the medium term;
To broaden, re-design and enhance its product
range to bring to the market an upgraded product
offering which will position CMP as the first
choice of Clients, and to continue this develop-ment process over the next five years.
To incur substantial investment in manufacturing
techniques, IT systems and training in order to
ensure CMP Products can offer unparalleled levels
of quality and customer service.
To develop strategic alliances with distributors and
end-users across the globe in order to provide
our products with access to a world class global
distribution network.
CMP ONLINEAs a leading manufacturer of metallic cable
glands and electrical mining products for
global applications CMP Products is
committed to ensuring it remains the
number one choice in its markets.
w w w. c m p - p r o d u c t s . c o m
MISSION STATEMENT
INVESTOR IN PEOPLE
VISION STATEMENT
To elevate the customer to the Centre of our activities and to employ
our endeavour to bring about a positive experience for everyone
-
8/17/2019 Cat-CMP Cable Gland
4/64
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
Introduction
Gland Selection Guideline
CMP Displacement Seal Concept
Guide To Hazardous Area Cable Selection
Introduction To ATEX Directives
Ingress Protection
IndustrialIntroduction to CMP Industrial Cable Glands
A2 Unarmoured Cable Glands
SS2K (GP) Sureseal 2000 Unarmoured
A2RC Unarmoured - Conduit Connection
V-TEC (A2P) Industrial
A4 Armoured - S.T.A (Tape Armour) Outer Seal
BW Armoured Cable Glands
BWL Armoured Cable Glands
CW Armoured - S.W.A Outer Seal
CX/ Z Armoured - Braided or S.T.A (Tape Armour) Outer Seal
E1W Armoured - S.W.A Inner/ Outer Seal
E2W Armoured - S.W.A -L.C. (Lead Sheathed) Inner/Outer Seal
E1X/Z Armoured - Braided or S.T.A (Tape Armour) Inner/Outer Seal
CWAL Armoured - A.W.A Outer Seal
Hazardous Area
Introduction to CMP Hazardous Area Cable Glands
A2F Unarmoured Outer Seal
SS2K Sureseal 2000 Unarmoured
A2FRC Unarmoured - Conduit Connection Outer Seal
V-TEC (A2Pe)- Hazardous Area
A4e Armoured - S.T.A (Tape Armour)
C2K Armoured - Multiple Armour Outer Seal
CWe Armoured - S.W.A Outer Seal
Cxe Armoured - Braided or S.T.A (Tape Armour) Outer Seal
TRITON (T3CDS) - Multiple Armour Inner/Outer Seal
E1FW Armoured - S.W.A Inner/ Outer SealE2FW Armoured - S.W.A - L.C. (Lead Sheathed) Inner/ Outer Seal
E1FX/Z Armoured - Braided or S.T.A (Tape Armour) Inner/Outer Seal
E2FX/Z Armoured - Braided or S.T.A (Tape Armour) Lead Sheathed Inner/Outer Seal
PX2K PROTEX 2000 - Armoured - Braided, S.W.A or S.T.A Outer Seal/Comp Barrier
Protex WR Armoured - S.W.A Outer Seal/Comp Barrier
Protex X/ZR Armoured - Braided Outer Seal/Comp Barrier
Protex SS2K Protex Sureseal 2000 Unarmoured Outer Seal/Comp Barrier
North America Specification Cable Connectors
Introduction to CMP North American Glands
PXSS2K Unarmoured Cable
C2KX Armoured & Jacketed - Wet Locations Outer Seal
PXB2KX Armoured CablePX2KX Armoured & Jacketed - Class 1 Div 1 Compound Barrier/ Outer Seal
MCRA
MCXA
Cable Gland Options & Accessories
Cable Gland Options
Accessories And Tools
Standard Selection Table For Adaptors & Reducers
Stopper Plugs & Insulated Adaptors
Cable Selector Charts
XLPE / EPR / SWA / PVC Cables BS5467
PVC / SWA / PVC Cables BS6346Unarmoured XLPE / PVC Cable To BS6883:9X (DRAFT)
3
4
5
6 - 7
8
9
10
11
12
13
14
15
16
17
18
19
20
2122
23
24
25
26
27
28
29
30
31
32
3334
35
36
37
38
39
40
41
42
43
4445
46
47
48 - 49
50 - 51
52 - 53
54 - 55
56
5758 - 59
-
8/17/2019 Cat-CMP Cable Gland
5/64
3
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
CableNPT or NPS M P.G. PF / BSP(JIS) Imperial
Gland ISO Metric(E.T.)
Size Preferred Option Preferred Option Preferred Option
16 M16 1/2” 3/4” 11 9, 13.5 - - -
20/16 M20 1/2” 3/4” 11 9, 13.5 1/2” - 3/4”
20S M20 1/2” 3/4” 13.5 11, 16 1/2” - 3/4”
20 M20 1/2” 3/4” 16 11, 13.5, 21 1/2” 3/4” 3/4”25 M25 3/4” 1” 21 - 3/4” 1” 1”
32 M32 1” 1-1/4” 29 - 1” 1-1/4” 1-1/4”
40 M40 1-1/4” 1-1/2” 36 29 1-1/4” 1-1.2” 1-1/2”
50S M50 1-1/2” 2” 36 42 1-1/2” - 2”
50 M50 2” 2-1/2” 42 48 2” - 2”
63S M63 2” 2-1/2” 48 - 2” - 2-1/2”
63 M63 2-1/2” 3” - - 2-1/2” - 2-1/2”
75S M75 2-1/2” 3” - - 2-1/2” - 3”
75 M75 3” 3-1/2” - - 3” 3-1/2” 3”
90 M90 3” 3-1/2” - - 3” 3-1/2” 3-1/2”
ENTRY THREAD OPTIONS
GLAND SELECTION GUIDELINES
The following is an extract from BS6121:Part 1, with edited additions to assist in gland selection :-
• Select the type of cable and identify a corresponding cable gland type from this catalogue.
• Check the type, size & voltage rating of the cable. Note for cables of 3.3kV & above the CMP-CIEL Gland is recommended.
• Check ACTUAL size of cable over the inner sheath / lead sheath against this catalogue.
• Check ACTUAL size of overall cable diameter against this catalogue.
• Check the size and type of armour or braiding, if any, against this catalogue.
• Check any special environment conditions including enclosure material in relation to corrosion.
• Check whether installation is in Hazardous Areas, & consider an environmental seal on the cable sheath for indoor/outdoor use.
• Check whether an entry thread seal is required for IP66 (or IP67/IP68) conditions.
• Check whether accessories, (ie. shrouds, slip on earth tags, locknuts etc) are required.
KEY to Hazardous Area Cable Glands = Increased Safety Type ‘e’ Dual Certified Type ‘d’ & ‘e’ Flameproof Type ‘d’■ ◆ ▲
NOTE :The table above details Standard (Preferred) and Optional Thread sizes which are available on all CMP ‘Double Seal’ Cable Gland types andSingle Seal Cable Glands for unarmoured cables (e.g.A2,A2F,A2RC,A2FRC). Please consult CMP for any requirements not covered by this table.
G L A N D S
E L E C T I O N G
U I D E L I N E S
BW
BWL
CW
Braided Unarmoured
CABLETYPECable Gland
Type SWA STASWA Lead
Sheathed
APPLICATIONSEALING CONFIGURATION
No Seal Inner SealDouble Outer
SealOuter Seal Outdoor Indoor Hazardous
●
●
● ●●
●
●●
●
●
C2KX
CWAL
E1W
E2W
CX
E1X/Z
A4
A2
SS2K GP
CWe
CXe
C2K
A4e
A2F
SS2K
E1FW
E2FW
E1FX/Z
WR
XR
PXB2KX
PX2K
PX2KXPXSS2K
●
●
●
●
●
●
●
●
●
●
●
●
● ● ● ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
● ● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
● ●● ●
● ●● ●
●
●
●
●
●
●
● ●
● ●
● ●
● ●
● ●
● ●
● ●
●
●
●
■
■
■
■
◆
● ●● ● ◆
● ●● ●
●
■
◆
● ● ◆
◆
◆
◆
▲
▲
▲
▲
▲
▲
Areas
A2RC
A2FRC
A2Pe
T3CDS
A2P
-
8/17/2019 Cat-CMP Cable Gland
6/64
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
C M P D I S P L A C M E N T S E A
L C O N C E P T
As it will be seen from the detailed technical datacontained within this catalogue the method of cablesealing in the CMP range of cable glands is fundamentally
different from that of it’s competitors. CMP has pioneeredthe use of displacement type seals which afford a largedegree of control in the tightening of the seals onto thecable sheath as opposed to conventional compressionseals which usually require the cable gland to be fullytightened on installation.The information below sets outto demonstrate the difference between the different sealtypes adopted and the reasons why CMP utilise thedisplacement seal very effectively in its Cable Gland range.
It has long been recognised that the difference in reactionpressure between the inner seal of a cable gland and thepolymeric material of the cable sheath can result in‘cold flow’ under load cycling. Soft bedded cables areparticularly prone to cold flow’. The latest EuropeanStandard EN60079 requires the user to install CableGlands which do not cause an adverse ‘cold flow’ reactionto the inner cable bedding,which would otherwise breachthe integrity of the form of the hazardous area protectionof the electrical apparatus. This is a particular problemwhen using cable glands fitted with conventionalcompression seals.To overcome this problem, the CMP cable gland design
incorporates a unique seal arrangement whereby the sealis displaced as the gland is tightened, virtually eliminatingany damage to the cable sheath. Additionally the CMP
design enables the user to control the level of displacement of the seal, and this level of control is afeature not found in other traditional cable glands.Duringdevelopment, tests were carried out on soft beddedcables, comparing these ‘displacement’ seals with thetraditional, ‘compression’ type seals. Significantly lessdistortion or damage to the cable sheath of soft beddedcables occurred when displacement seals were used.Obviously in hazardous area installations, the ongoingeffectiveness of the inner seal of the cable gland representsa critical link in the chain of safety. In recognition of this,the CMP cable glands enable the effectiveness of thecritical inner seal to be easily checked on an ongoing basisin a way that no other cable gland types allow.
The CMP displacement seal concept has been proven overmany years in service and has been endorsed by majorusers globally as the preferred solution for explosionproof and industrial installations
(See also TRITON CDS - compensating DisplacementSeal System on Pg 32)
DISPLACEMENT SEALS COMPRESSION SEALS
Relaxed Compressed With Controlled Compression
Inner Outer
RELATIVE EFFECTS ON CABLE SHEATH
Note : Cable performance can be affected by Compression Type Seals employed on either the Inner Sheath or the Outer Sheath
With Displacement Seal With Compression Seal
CRUCIAL CABLE CARE - THE DISPLACEMENT SEAL CONCEPTYET ANOTHER ORIGINAL FROM CMP
4
-
8/17/2019 Cat-CMP Cable Gland
7/64
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
G
U I D E T O H
A Z A R D O U S A R E A G
L A N D
S E L E C T I O N
INTERPRETATION OF HAZARDOUS AREA CODE OF PRACTICE FOR
SELECTION OF COMPOUND BARRIER TYPE CABLE GLANDS
Direct entry into
Flameproof
Type ‘d’ enclosure
Indirect entry into
Flameproof
Type ‘d’ enclosure
For cables entering FlameproofType ‘d’ enclosures indirectly,
a Compound BarrierCable Gland need not be used.
Ex ‘d’ TerminalCompartment
Conventional CableGland with Sealing
Rings (e.g. P2K)Line
Barriers
For cables entering directly intoFlameproof Type ‘d’ enclosures, a
Compound Barrier Cable Glandis sometimes required.
✝ If in doubt consult with the
cable supplier or cable manufacturer.
Compound BarrierGland (e.g. PX2K) 5
Selection process for cables directly
entering Ex ‘d’ enclosures.
-
8/17/2019 Cat-CMP Cable Gland
8/64
Directive 99/92/EC requires employers to protect workers from the risk of explosive atmospheres. An explosive atmosphere is definedas a mixture with air, under atmospheric conditions, of dangerous substances in the form of gases, vapours,mist or dust in which afterignition has occurred, combustion spreads to the entire unburned mixture. ATEX 137 implemented in the UK as DSEAR:
Dangerous Substances and Explosive Atmosphere Regulations 2002Statutory Instrument 2002 No.2776 (Mandatory from 9th December 2002)
SurfaceIndustries
Risk Assessment
Risk Assessment
Risk assessment does not include:a) Likelyhood that an explosive
atmosphere will occur,b) Ignition source,c) Scale of explosion, andd) any places connected via
opening to the explosive atmosphere
Risk assessment does not include:a) Likelyhood that an explosive
atmosphere will occur,b) Ignition source,c) Scale of explosion, and
d) any places connected viaopening to the explosive atmosphere
Medical areasGas appliances
(domestic)Gas Fittings
Manufacture,handling,storage of explosives.
Borehole SiteMeans of transport bylandor seas (does not
include transportintended for use inhazardous)
MODEstablishment
No
Yes
Yes
No
ATEX 99/92/EC does not apply
Yes
No
Mines &Quarries
Reduce therisk fromdangerous
substances
Classification of workplaces intoHazardous/non-Hazardous Area
(mandatory1st July 2003)
Procedures onaccidents,incidents
emergencies
InformationInstruction and
Training
Procedures onaccidents,incidents
emergencies
InformationInstruction and
Training
Procedures on accidents, incidentsemergencies. 8(1)(d)-(In explosive
conditions audible and visual alarmsrequired) not applicable
InformationInstruction and
Training
DSEAR doesNOT apply
DSEAR doesNOT apply
Reduce therisk fromdangerous
substances
Offshore Oil &Gas platforms
Ships
Secretary of Statesissues certification
of exemption
ExemptionsGeneral Safety Measures• Workplace and Work ProcessessThe following do not apply:a) UPS backupb) manual override shutdown
buttonsc) energy to be dissipated after
operation of emergency shutdown
• Systems of Work a) need for written instructions
for carrying out the work;b) permits to work
HM Navy
Summary of the main requirement for DSEAR is given below:
• Carry out a risk assessment of any work activities involvingdangerous substances;
• Provide technical and organisational measures to eliminate or
reduce to, as far as is reasonably practical, the identified risks;• Provide equipment and procedures to deal with accidents and
emergencies;• Provide information and training to employees;
• Classify places where explosive atmospheres may occur into zones,and mark the zones where necessary.
Other than for certain maritime activities, DSEAR applies whenever the
following conditions have been satisfied:
1) There is work being carried out by an employer or self-employed person;
2) A dangerous substance is present or liable to be present at the workplace;
3) The dangerous substance presents a risk to the safety of persons
(as opposed to a risk to health).
The requirements of DSEAR concerning zoning and co-ordination of safety
measures in shared workplaces (Regulation 7 & 11 of DSEAR) do not apply to
all workplaces where other legislation is in place.
Typical Cable Gland Marking for ATEXCable Glands carrying ATEX approval will typically be marked thus:
Cable Gland MarkingExample of additional Cable Gland marking according to Form of Protection
CertificateHolder
ATEXGeneration
ApparatusGroup
Form of
Protection 1
Form of
Protection 2
ApprovedGas Group
Ex StatusG=GasD=Dust
Postcode SignifiesAddress of
ManufacturerSpecial Condition
Temperature RatingQA Notified
Body Number
‘X’ - Denotes thatSpecial ConditionsFor Safe Use Exit
Year of 1stApproval
SpecificApproval No.
EquipmentCategory
Country of Manufacture
CE Mark Signifies Full Compliancewith EN Standards
SIRA 00 ATEX 1148 X II 2 GD
EEx d IIC EEx e II Type 4X Oil Res II
NE6 1BS UK -60˚C + -130˚C 0518
Additional
Approval Mark
Oil Resistance
Rating
ApprovedGas Group
AdditionalNEMA Rating
99/92/EC
Doc Ref : TPC 164 issue 04 2005
I N T R O D U C T I O N T O A T E
X
D I R E C T I V E S
6
-
8/17/2019 Cat-CMP Cable Gland
9/64
A T E X D
I R E C T
I V E
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
Directive 94/9/EC (ATEX 95) Equipment and Protective Systems for use in potentially explosive atmospheres.Covers electrical andnon-electrical products intended for use in hazardous areas (gas, vapours or dust atmospheres).ATEX 95 implemented in the UK as :
The Equipment and Protective Systems Intended for USE in PotentiallyExplosive Atmosphere Regulations 1996 Statutory instrument 1996 No. 192
Zoning Definitions
94/9/EC
Zones
EN60079-10 EN50281-3
Definitions
Zone IP RatingATEX Category
BSEN 50281-1-1/2
Gas
0 20
A place in which an explosive atmosphere is likely to occur innormal operation occasionally.
Type of Protection
Intrinsic Safety
Increased Safety
Flameproof
Pressurisation
Powder Filling
Encapsulation
Oil Immersion
Type n
EEx is & ib
EEx e
EEx d
EEx p
EEx q
EEx m
EEx o
EEx n
EN 50020
EN 50019
EN 50018
EN 50016
EN 50017
EN 50028
EN 50015
EN 50021
Dusts
20
21
22
IP6X
IP6X
IP5X
Requires 1D equipment
Requires 1D or 2D equipment
Requires 3D, 2D, 1D equipment
*Must be IP6X if dust is electrically conductive
A place in which an explosive atmosphere is not likely to occurin normal operation, but if it does only occurs for short periods.
1 21
2 22
Dust
Zoning Definitions
ATEX
Cat.
Typical Zone
Suitability
1G1D
2G2D
2G2D
Equip. suitable for zones 0Equip. suitbale for zones 20
Equip. suitable for zones 1Equip. suitbale for zones 21
Equip. suitable for zones 2Equip. suitbale for zones 22
A place in which an explosive atmosphere is continuily present.
Type of Protection
CENELECCode
ENStandard
Non-electrical equipment (concepts)
EN 13463-1
EN 13463-2
EN 13463-3
EN 13463-4
EN 13463-5
EN 13463-6
EN 13463-7
EN 13463-8
Basic methods & requirements
Flow restricting enclosure
Flame-proof enclosure
Inherent safety
Constructional Safety
Control of ignition sources
Pressurisation
Liquid immersion
fr
d
g
c
b
p
k
Conformity Assessment ‘Quality Modules’
Design Phase
EC-Type Examination
Internal Control of Production
Unit Vertification
Production Phase
Production Quality Assurance
Product Quality Assurance
Product Verification
Conformity to Type
Internal Control of Production
Unit Verification
*Notes:1 “Global Approach” OJEC No. L220, 19932 ATEX Directive 94/9/EC3 Suffix (E) refers to electrical equipment and internal combustion engines
Suffix (N) refers to non-electrical equipment4 Technical Files to be deposited with a notified body
KEY= mandatory unless Unit Verification is used= optional as an alternative to other modules
Y = one of two production phase modules for the equipment category tobe chosen by the manufacturer
Module
*1
B
A
G IX
D IV
E VII
F V
C VI
A VIII
G IX
VIII
III
Y
Y
Y
Y Y Y
Y
Y
Y Y
O OOOOOO O
O OOOOOO O
O
AnnexM1 M2
(E)M2(N)
1 2(E)
2(N)
3Prodective
System
Equipment Category *3
*2
Enclosed break device CNon-incendive component CHermetically sealed device CSealed device CEncapsulated device CEnergy limited apparatus and circuits LRestricted breathing enclosure RSimplified pressurisation PNon sparking A
T1
T2
T3
T4
T5
T6
450
300
200
135
100
85
Type n equipmentcontaining:
Additionalcode letter TClass
Maxsurface
temp in˚C
*4 *4
7
-
8/17/2019 Cat-CMP Cable Gland
10/64
I N G R E S S
P R O T E
C T I O N
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
DEGREE OF INGRESS PROTECTION (IP CODE) IN ACCORDANCE WITH EN 60529 : 1991
CMP cable glands comply with the requirements of EN60529:1991 (IEC 529) in respect of I.P. ratings. Some cable glandtypes have been tested to IP66, whilst other types have been tested to IP66, IP67 & IP68, to a depth of 10 metres. *
Protected against access
to hazardous parts with
the back of a hand
0 0 Non-protected
1 1Protected against
drops of water
falling vertically
2 2Protected againstdrops of water
falling at up to 15º
from the vertical
3 3
Protected against
spraying water at
up to 60º from
the vertical
4 4Protected againstsplashing water
from all directions
5 5
Protected against
jet of water from
all directions
Protected against
jet of water of
similar force to
heavy seas
Protected against
the effects of
immersion
Protected against
prolonged effects
of immersion
under pressure toa specified depth
6 6
50mm
12mm
2.5mm
1mm
Protected against solid
foreign objects of
50mm diameter
and greater
PROTECTION AGAINST SOLID FOREIGN OBJECTSAND ACCESS TO HAZARDOUS PARTS
PROTECTION AGAINSTLIQUIDS
Protected against solidforeign objects of
12.5mm diameter
and greater
Protected against solid
foreign objects of
2.5mm diameter
and greater
Protected against solidforeign objects of
1.0mm diameter
and greater
Dust-protected
Non-protected
F i r s t D
i g i t
S e c o n d D i g i t
Non-protected
Dust-tight
Protected against accessto hazardous parts with
a finger
Protected against access
to hazardous parts with
a tool
Protected against accessto hazardous parts with
a wire
Protected against access
to hazardous parts with
a wire
Protected against accessto hazardous parts with
a wire
1m
m
7
8
1 5 c m
( m i n )
* Please refer to appropriate catalogue pages for specific ratingsaccording to their design and construction.
In addition to the Ingress Protection tests carried out as standard on theCMP range of Cable Glands, selected products have additionally beentested to meet the requirements of NEMA 4X in accordance with NorthAmerican standards. Please refer to catalogue pages for specific productcompliance.
8
-
8/17/2019 Cat-CMP Cable Gland
11/64
APPL ICAT ION
The CMP range of Industrial Cable Glands embraces products used in a
wide and diverse variety of market sectors, in conjunction with virtually
every kind of industrial cable. With a wealth of experience in terminating
all types of armoured and unarmoured cables CMP have discovered that
when it comes to such critical installations, quality really does count.
PRODUCTS
Cable Gland options for all types of cable
SPECIFICATIONS & APPROVALS
Largely based around the BS6121 & BS7394 standards CMP deliver
product produced strictly under ISO9001 controls.CMP Cable glands also conform to BSEN50262.
R A N G E
CMP PRODUCTS
© BP Amoco p.l.c. 1997
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
-
8/17/2019 Cat-CMP Cable Gland
12/64
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
10
U N A R M O U R E D
C A B L E
A
B
C
D
A2 GLAND
Minimum Across Ordering PVC
Gland SizeStandard Entry Threads ‘B’
ThreadCable Dia ‘A’
Corners Reference Shroud
Metric NPT PG Length ‘C’ Min Max Dia ‘D’ Max (Metric) Ref.
16 16 1/2” PG11 10 3.1 8.6 24.4 16A2 PVC02
20/16 20 1/2” PG11 15 3.1 8.6 24.4 20/16A2 PVC02
20S 20 1/2” PG13.5 10 6.1 11.6 26.5 20SA2 PVC04
20 20 1/2” PG16 10 6.5 13.9 30.0 20A2 PVC05
25 25 3/4” PG21 10 11.1 19.9 39.9 25A2 PVC09
32 32 1” PG29 10 17.0 26.2 45.5 32A2 PVC10
40 40 1-1/4” PG36 15 22.0 32.1 55.4 40A2 PVC13
50S 50 1-1/2” PG36 15 29.5 38.1 61.0 50SA2 PVC14
50 50 2” PG42 15 35.6 44.0 66.5 50A2 PVC17
63S 63 2” PG48 15 40.1 49.9 77.6 63SA2 PVC20
63 63 2-1/2” - 15 47.2 55.9 83.2 63A2 PVC22
75S 75 2-1/2” - 15 52.8 61.9 88.7 75SA2 PVC24
75 75 3” - 15 59.1 67.9 94.2 75A2 PVC2690 90 3” - 15 66.6 79.3 120.7 90A2 PVC31
All Dimensions in Millimetres
A2 Industrial Cable Gland
Brass indoor and outdoor cable gland for all types of unarmoured cable
providing a seal on the outer sheath.
TECHNICAL DATA
TYPE A2
DESIGN SPECIFICATION BSEN50262
INGRESS PROTECTION IP66, I P67 & IP68 (10M DEPTH)
GLAND MATERIAL BRASS
SEAL MATERIAL CMP SOLO LSF
CABLE TYPE UNARMOURED
SEALING TECHNIQUE CMP DISPLACEMENT SEAL CONCEPT
SEALING AREA OUTER SHEATH
* SOLO Option with LSF Seals & LSF Shrouds also AvailableIntegral Entry Thread Seal Option also available, For this Option prefixgland type with ‘R’, e.g. 25RA2Also available in Brass with Nickel Plated Finish
ADDITIONAL APPROVALS
MARINE APPROVALS LLOYDS,ABS
GOST CERTIFICATE OF CONFORMITY 5318856
OPTIONAL ACCESSORIES SHROUD, LOCKNUT, SERRATED WASHER
ENTRY THREAD SEAL, ADAPTOR/REDUCER
-
8/17/2019 Cat-CMP Cable Gland
13/64
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
TYPE SS2K GP (SS2KPB GP FOR LEAD
SHEATHED CABLES).
DESIGN SPECIFICATION BSEN50262
INGRESS PROTECTION IP66, IP67 & IP68 (10M DEPTH )
GLAND MATERIAL BRASS
SEAL MATERIAL THERMOPLASTIC ELASTOMER
CABLE TYPE UNARMOURED
SEALING TECHNIQUE CMP DISPLACEMENT SEAL CONCEPT
SEALING AREA(S) OUTER SHEATH (DOUBLE SEAL)
OPTIONAL ACCESSORIES LOCKNUT, E ARTH TAG, SERRATED WASHER
ENTRY THREAD SEAL, ADAPTOR/REDUCER
* SOLO Option with LSF Seals also AvailableIntegral Entry Thread Seal Option Available(for this option pre-fix gland type with ‘R’, e.g. 25RSS2KGP)
Standard Entry Minimum Cable Dia ‘A’ / ‘B’ Across Ordering
Gland Size Threads ‘C’ Thread Millimetres Corners Reference
Metric NPT PG Length ‘D’ Min Max Dia ‘E’ Max (Metric)
16 16 1/2” PG11 10 3.1 8.6 24.4 16SS2KGP
20/16 20 1/2” PG11 15 3.1 8.6 24.4 20/16SS2KGP
20S 20 1/2” PG13.5 10 6.1 11.6 26.5 20SSS2KGP
20 20 1/2” PG16 10 6.5 13.9 30.0 20SS2KGP
25 25 3/4” PG21 10 11.1 19.9 39.9 25SS2KGP
32 32 1” PG29 10 17.0 26.2 45.5 32SS2KGP
40 40 1-1/4” PG36 15 22.0 32.1 55.4 40SS2KGP
50S 50 1-1/2” PG36 15 29.5 38.1 61.0 50SSS2KGP
50 50 2” PG42 15 35.6 44.0 66.5 50SS2KGP
63S 63 2” PG48 15 40.1 49.9 77.6 63SSS2KGP
63 63 2-1/2” - 15 47.2 55.9 83.2 63SS2KGP
75S 75 2-1/2” - 15 52.8 61.9 88.7 75SSS2KGP
75 75 3” - 15 59.1 67.9 94.2 75SS2KGP90 90 3” - 15 66.6 79.3 120.7 90SS2KGP
All Dimensions in Millimetres
A
B
C
D
E
SS2K (GP) GLANDSURESEAL 2000 GP Industrial Cable Gland
Indoor and Outdoor Brass Cable Gland for all types of Unarmored Cables,
providing an environmental seal on the cable inner and outer sheaths, or a
double seal to the cable outer sheath. Suitable for applications where superior
cable pull out resistance and stability is required.Type SS2KPB GP available for
unarmoured cables with lead sheath.
TECHNICAL DATA
U N A R M O U R E D
C A B L E
11
-
8/17/2019 Cat-CMP Cable Gland
14/64
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
TECHNICAL DATA
TYPE A2RC
DESIGN SPECIFICATION BSEN50262
INGRESS PROTECTION IP66, IP67 & IP68 (10M DEPTH)
GLAND MATERIAL BRASS
SEAL MATERIAL THERMOPLASTIC ELASTOMER
CABLE TYPE UNARMOURED
SEALING TECHNIQUE CMP DISPLACEMENT SEAL CONCEPT
SEALING AREA (S) OUTER SHEATH
OPTIONAL ACCESSORIES LOCKNUT, E ARTH TAG, S ERRATED
WASHER ENTRY THREAD SEAL,
ADAPTOR/REDUCER
* SOLO Option with LSF Seals also Available
A2RC Industrial Cable Gland for Conduit Connection
Standard Male Entry Minimum ✝ Standard AcrossOrdering
Gland Size Connection Threads ‘B’ Thread Female NPTCable Dia ‘A’
CornersReference
Metric NPT PG Length ‘C’ Threads Min Max Dia ‘D’ Max
20/16 20 1/2” PG11 15 1/2” 3.1 8.6 30.0 20/16A2RC20S 20 1/2” PG13.5 10 1/2” 6.1 11.6 30.0 20SA2RC
20 20 1/2” PG16 10 1/2” 6.5 13.9 30.0 20A2RC
25 25 3/4” PG21 10 3/4” 11.1 19.9 39.9 25A2RC
32 32 1” PG29 10 1” 17.0 26.2 45.5 32A2RC
40 40 1-1/4” PG36 15 1-1/4” 22.0 32.1 55.4 40A2RC
50S 50 1-1/2” PG36 15 1-1/2” 29.5 38.1 61.0 50SA2RC
50 50 2” PG42 15 2” 35.6 44.0 72.1 50A2RC
63S 63 2” PG48 15 2” 40.1 49.9 77.6 63SA2RC
63 63 2-1/2” - 15 2-1/2” 47.2 55.9 88.7 63A2RC
75S 75 2-1/2” - 15 2-1/2” 52.8 61.9 88.7 75SA2RC
75 75 3” - 15 3” 59.1 67.9 105.3 75A2RC
90 90 3” - 15 3” 66.6 79.3 120.7 90A2RC
All Dimensions in Millimetres
✝ Female connection threads in NPT, other thread forms manufactured to order. When ordering please confirm Male & Female Threads required.
Brass indoor and outdoor conduit connection cable gland for all types of
unarmoured cables housed in rigid or flexible conduit systems.The gland
is equipped with a rotating male or female connection for ease of conduit
installation.
12
U N A R M O U R E D C A B L E S
I N C O N D U I T
A
B
C
D
A2RC GLAND
Female Connection
Threads Illustrated
-
8/17/2019 Cat-CMP Cable Gland
15/64
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
U N A R M O U R E D
C A B L E
13
V-Tec (A2P) Industrial
*Sealing range based upon strain relief & twist protection to VDE 0619 - Available colours: Black, Light Grey (RAL 7001) & Silver Grey (RAL 7035).For colour options please add the folowing suffix to the ordering codes above: B= Black. G= Light Grey. S= Silver GreyOther colours and other non-metallic products in the V-TEC range are also available, please consult CMP Products for further information.
TYPE DESIGNATION V-TEC, L & M (A2P)
CABLE GLAND MATERIAL POLYAMIDESEAL MATERIAL CMP SOLO LSF
FLAME RETARDANCY SPECIFICATION VDE 0471/IEC 695 PART 2-1
WITHSTAND TEMPERATURE TESTED +750˚C
CERTIFIED CONTINUOUS OPERATING -20˚C TO +70˚C
TEMPERATURE RANGE
INGRESS PROTECTION IP68(AT 5 BAR) TO VDE 0619 / IEC529 ETS
CABLE TYPE UNARMOURED
SEALING AREA OUTER SHEATH
SEALING TECHNIQUE CONTROLLED SEAL WITH STRAIN RELIEF
OPTIONAL ACCESSORIES LOCKNUT
TECHNICAL DATA
CMP V-TEC - & L Cable Glands (A2P) - General Purpose Industrial Type
A2P1 / A2LP1 Pg 7 8.0 15.0 2.5 6.5 3.0 6.5 18.0 23.0 15.0 16.5 0.41 50
A2P2 / A2LP2 Pg 9 8.0 15.0 2.5 8.0 3.5 8.0 21.0 27.0 19.0 21.0 0.67 50
A2P3 / A2LP3 Pg 11 8.0 15.0 3.5 10.0 4.5 10.0 22.0 29.0 22.0 25.0 0.93 50
A2P4 / A2LP4 Pg 13.5 9.0 15.0 5.0 12.0 6.0 12.0 23.0 30.0 24.0 27.0 1.09 50
A2P5 / A2LP5 Pg 16 10.0 15.0 7.0 14.0 7.0 14.0 25.0 33.0 27.0 30.0 1.49 25
A2P6 / A2LP6 Pg 21 11.0 15.0 9.0 18.0 12.0 18.0 28.0 38.0 33.0 37.5 2.33 25
A2P7 / A2LP7 Pg 29 11.0 15.0 14.0 25.0 17.0 25.0 32.0 43.0 42.0 47.5 3.86 20
A2P8 / A2LP8 Pg 36 13.0 18.0 18.0 32.0 20.0 32.0 39.0 54.0 53.0 60.0 7.75 10
A2P9 / A2LP9 Pg 42 13.0 18.0 24.0 38.0 26.0 38.0 42.0 57.0 60.0 68.5 10.07 5
A2P10 / A2LP10 Pg 48 14.0 18.0 30.0 44.0 30.0 44.0 42.0 58.0 65.0 74.0 10.73 5
Size Ref.Thread
Size ‘A’
Cable Acceptance Range ‘C’
Min MaxSTD L
Across
FlatsAcross
CornersWeight
(KG/100)
Pack QTY.
Thread
Length ‘B’
Min Max
Standard Reduced*Overall Length ‘D’
Min Max
CMP V-TEC M Cable Glands (A2P) - General Purpose Industrial Type
A2MP1 M12 8.0 2.5 6.5 3.0 6.5 18.0 23.0 15.0 16.5 0.36 50
A2MP2 M16 8.0 2.5 8.0 3.5 8.0 21.0 27.0 19.0 21.0 0.63 50
A2MP3 M20 9.0 5.0 12.0 6.0 12.0 23.0 30.0 24.0 27.0 1.00 50
A2MP4 M25 11.0 9.0 18.0 12.0 18.0 28.0 38.0 33.0 37.5 2.35 25
A2MP5 M32 11.0 14.0 25.0 17.0 25.0 32.0 43.0 42.0 47.5 3.90 20
A2MP6 M40 13.0 18.0 32.0 20.0 32.0 39.0 54.0 53.0 60.0 7.50 10
A2MP7 M50 13.0 24.0 38.0 26.0 38.0 42.0 57.0 60.0 68.5 9.20 5
A2MP8 M63 14.0 30.0 44.0 30.0 44.0 42.0 58.0 65.0 74.0 9.66 5
Size Ref.Thread
Size ‘A’
Cable Acceptance Range ‘C’
Min Max
Across
FlatsAcross
Corners
Weight
(KG/100)
Pack QTY.
Thread
Length ‘B’Min Max
Standard Reduced*Overall Length ‘D’
Min Max
Plastic gland for use with unarmoured cables
V-Tec Ordering References
-
8/17/2019 Cat-CMP Cable Gland
16/64
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
14
A R M O U R E D C A B L E S T A
A
B
C
D
E
A4 GLAND
Brass indoor and outdoor cable gland for all types of Steel Tape Armour
Cable providing a seal on the cable outer sheath and a continuity seal on
the Tape Armour.
TECHNICAL DATA
TYPE A4
DESIGN SPECIFICATION BSEN50262
INGRESS PROTECTION IP66
GLAND MATERIAL BRASS
SEAL MATERIAL CMP SOLO LSF
CABLE TYPE STEEL TAPE ARMOUR
ARMOUR TERMINATION METALLIC CONTINUITY SEAL
SEALING TECHNIQUE CMP DISPLACEMENT SEAL CONCEPT
SEALING AREA OUTER SHEATH
OPTIONAL ACCESSORIES SHROUD, LOCKNUT, EARTH TAG,
SERRATED WASHER, ENTRY THREAD SEAL,
ADAPTOR/REDUCER
A4 Industrial Cable Gland
Minimum Across Ordering PVC
Gland SizeStandard Entry Threads ‘C’
ThreadCable Dia ‘A’ Cable Dia ‘B’
Corners Reference Shroud
Metric NPT PG Length ‘D’ Min Max Min Max Dia ‘E’ Max (Metric) Ref.
20S 20 1/2” PG13.5 10 6.5 11.6 6.1 11.6 26.5 20SA4 PVC0420 20 1/2” PG16 10 10.0 13.9 6.5 13.9 30.0 20A4 PVC05
25 25 3/4” PG21 10 11.6 19.9 11.1 19.9 39.9 25A4 PVC09
32 32 1” PG29 10 19.0 26.2 17.0 26.2 45.5 32A4 PVC10
40 40 1-1/4” PG36 15 25.0 32.1 22.0 32.1 55.4 40A4 PVC13
50S 50 1-1/2” PG36 15 27.5 38.1 29.5 38.1 61.0 50SA4 PVC15
50 50 2” PG42 15 33.1 44.0 35.6 44.0 66.5 50A4 PVC18
63S 63 2” PG48 15 40.1 49.9 40.1 49.9 77.6 63SA4 PVC21
63 63 2-1/2” - 15 47.2 55.9 47.2 55.9 83.2 63A4 PVC23
75S 75 2-1/2” - 15 43.5 61.9 52.8 61.9 88.7 75SA4 PVC24
75 75 2-1/2” - 15 49.8 67.9 59.1 67.9 94.2 75A4 PVC26
90 90 3” - 15 64.0 79.3 66.6 79.3 120.7 90A4 PVC31
All Dimensions in Millimetres
-
8/17/2019 Cat-CMP Cable Gland
17/64
A R M O U R E D C A B
L E S W A
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
15
BW GLAND / PACK
A
B
C
D
E
BW Industrial Cable Gland
BW Industrial Gland Kits
Brass indoor gland for use with all types of SWA cable, providing mechanicalcable retention and electrical continuity via armour wire termination.
TECHNICAL DATA
TYPE BW
DESIGN SPECIFICATION BS6121 : PART 1 : 1989
INGRESS PROTECTION IP2X
GLAND MATERIAL BRASS
CABLE TYPE STEEL WIRE ARMOUR
ARMOUR CLAMPING TWO PART ARMOUR LOCK
OPTIONAL ACCESSORIES SHROUD, LOCKNUT, EARTH TAG,
SERRATED WASHER,ADAPTOR/REDUCER
ADDITIONAL APPROVALS
MARINE APPROVALS LLOYDS,ABS
* SOLO Option with LSF Shrouds also Available
Also available in Brass with Nickel Plated Finish
Gland kit for use with all types of SWA cable, including 2 Brass Glands, 2 SteelLocknuts, 2 Brass Earth Tags and 2 PVC Shrouds for sizes up to and including32mm. For sizes 40mm and above each kit includes 1 off each component
✝ For Gland Packs change the ordering code reference above accordingly. eg. 20SBWKIT
Gland SizeMetric Minimum Cable Cable Armour Across Ordering PVC
Entry Thread Dia ‘A’ Dia ‘B’ Wire Corners Reference Shroud
Thread ‘C’ Length ‘D’ Max Max Dia Dia ‘E’ Max (Gland Only) Ref.
20S 20 10 11.6 16.1 0.9/1.25 24.0 20SBW PVC02
20 20 10 13.9 21.1 0.9/1.25 30.0 20BW PVC05
25 25 10 19.9 27.4 1.25/1.6 36.0 25BW PVC07
32 32 10 26.2 34.4 1.6/2.0 44.5 32BW PVC10
40 40 15 32.1 42.4 1.6/2.0 56.3 40BW PVC13
50S 50 15 38.1 50.1 2.0/2.5 63.4 50SBW PVC16
50 50 15 44.0 55.7 2.0/2.5 72.1 50BW PVC19
63S 63 15 50.0 62.4 2.5 83.0 63SBW PVC22
63 63 15 55.9 68.2 2.5 88.7 63BW PVC24
75S 75 15 61.9 76.8 2.5 99.8 75SBW PVC27
75 75 15 67.9 82.9 2.5/3.15 105.3 75BW PVC29
Dimensions in Millimetres
-
8/17/2019 Cat-CMP Cable Gland
18/64
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
A R M O U R E D C A B
L E S W A
A
B
C
D
E
BWL GLAND
16
Brass indoor gland for use with all types of SWA cable providing mechanical
cable retention and electrical continuity via armour wire termination.
BWL Heavy Duty Industrial Cable Gland
TECHNICAL DATA
TYPE BWL
DESIGN SPECIFICATION BS6121 : PART 1 : 1989
INGRESS PROTECTION IP2X
MATERIAL BRASS
CABLE TYPE STEEL WIRE ARMOUR
ARMOUR CLAMPING TWO PART ARMOUR LOCK
OPTIONAL ACCESSORIES LOCKNUT, EARTH TAG, SHROUD,
ENTRY THREAD SEAL, SERRATED WASHER
* SOLO Option with LSF Shrouds also Available
Also available in Brass with Nickel Plated Finish
ADDITIONAL APPROVALS
MARINE APPROVALS LLOYDS,ABS
Gland SizeMetric Minimum Cable Cable Armour Across
OrderingPVC
Entry Thread Dia ‘A’ Dia ‘B’ Wire CornersReference
Shroud
Thread ‘C’ Length ‘D’ Max Max Dia Dia ‘E’ Max Ref.
20/16 20 15 8.6 13.4 0.9 24.4 20/16BWL PVC02
20S 20 10 11.6 15.9 0.9/1.25 26.6 20SBWL PVC04
20 20 10 13.9 20.9 0.9/1.25 33.3 20BWL PVC06
25 25 10 19.9 27.4 1.25/1.6 39.9 25BWL PVC09
32 32 10 26.2 33.9 1.6/2.0 51.0 32BWL PVC11
40 40 15 32.1 40.4 1.6/2.0 56.3 40BWL PVC13
50S 50 15 38.1 46.7 2.0/2.5 66.5 50SBWL PVC17
50 50 15 44.0 53.1 2.0/2.5 77.6 50BWL PVC20
63S 63 15 50.0 62.4 2.5 83.0 63SBWL PVC22
63 63 15 55.9 68.2 2.5 88.7 63BWL PVC25
75S 75 15 61.9 72.1 2.5 99.8 75SBWL PVC28
75 75 15 67.9 78.5 2.5/3.15 111.1 75BWL PVC30
90 90 15 79.3 90.4 3.15 128.6 90BWL PVC32
Dimensions in Millimetres
-
8/17/2019 Cat-CMP Cable Gland
19/64
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
A R M O U R E D C A B
L E S W A
D
A
B
C
E
CW GLAND
17
CW Industrial Cable Gland
CW Industrial Gland Kits
Brass indoor and outdoor gland for all types of SWA cable, providingenvironmental seal on the cable outer sheath.The gland also providesmechanical cable retention and electrical continuity via armour wiretermination.
TECHNICAL DATA
TYPE CW
DESIGN SPECIFICATION BSEN50262
INGRESS PROTECTION IP66
GLAND MATERIAL BRASS
SEAL MATERIAL CMP SOLO LSF
CABLE TYPE STEEL WIRE ARMOUR
ARMOUR CLAMPING TWO PART ARMOUR LOCK
(THREE PART OPTION AVAILABLE)
SEALING TECHNIQUE CMP DISPLACEMENT SEAL CONCEPT
SEALING AREA OUTER SHEATH
OPTIONAL ACCESSORIES SHROUD, LOCKNUT, EARTH TAG,
ENTRY THREAD SEAL, SERRATED WASHER
ADAPTOR/REDUCER
ADDITIONAL APPROVALS
MARINE APPROVALS ABS
* SOLO Option with LSF Shrouds also Available
Also available in Brass with Nickel Plated Finish
Gland kit for use with all types of SWA cable, including 2 Brass Glands, 2 SteelLocknuts, 2 Brass Earth Tags and 2 PVC Shrouds for sizes up to and including32mm. For sizes 40mm and above each kit includes 1 off each component
Gland SizeMetric Minimum Cable Cable Armour Across Ordering PVC
Entry Thread Dia ‘A’ Dia ‘B’ Wire Corners Reference Shroud
Thread ‘C’ Length ‘D’ Max Min Max Dia Dia ‘E’ Max (Gland Only) Ref.
20/16 20 15 8.6 6.0 13.4 0.9 24.4 20/16CW PVC02
20S 20 10 11.6 9.5 15.9 0.9/1.25 26.6 20SCW PVC04
20 20 10 13.9 12.5 20.9 0.9/1.25 33.3 20CW PVC06
25 25 10 19.9 17.0 26.2 1.25/1.6 40.5 25CW PVC09
32 32 10 26.2 22.9 33.9 1.6/2.0 51.0 32CW PVC11
40 40 15 32.1 26.0 40.4 1.6/2.0 61.0 40CW PVC15
50S 50 15 38.1 35.0 46.7 2.0/2.5 66.5 50SCW PVC18
50 50 15 44.0 38.0 53.1 2.0/2.5 77.7 50CW PVC21
63S 63 15 50.0 45.6 59.4 2.5 83.2 63SCW PVC23
63 63 15 55.9 54.6 65.9 2.5 88.7 63CW PVC25
75S 75 15 61.9 57.0 72.1 2.5 101.6 75SCW PVC28
75 75 15 67.9 60.4 78.5 2.5/3.15 111.1 75CW PVC30
90 90 15 79.3 69.2 90.4 3.15 128.6 90CW PVC32
All Dimensions in Millimetres
✝ For Gland Kits change the ordering code reference above accordingly. eg. 20SCWKIT
-
8/17/2019 Cat-CMP Cable Gland
20/64
18
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
B R A I D E D O R S T A C A B L E
CX/Z GLAND CX / Z Industrial Cable Gland
* SOLO Option with LSF Shrouds also Available
Also available in Brass with Nickel Plated Finish
ADDITIONAL APPROVALS
MARINE APPROVALS LLOYDS,ABS
GOST CERTIFICATE OF CONFORMITY 5318856
Brass indoor and outdoor cable gland for all types of braided or steel tape
armour (S.T.A.) cables providing environmental seal on the cable outer sheath.
The gland also provides mechanical cable retention and electrical continuity via
wire braid or steel tape armour termination.
TECHNICAL DATA
TYPE CX/Z
DESIGN SPECIFICATION BSEN50262
INGRESS PROTECTION IP66
GLAND MATERIAL BRASS
SEAL MATERIAL CMP SOLO LSF
CABLE TYPE WIRE BRAID OR STEEL TAPE ARMOUR
ARMOUR CLAMPING THREE PART ARMOUR LOCK
SEALING TECHNIQUE CMP DISPLACEMENT SEAL CONCEPT
SEALING AREA OUTER SHEATH
OPTIONAL ACCESSORIES SHROUD, LOCKNUT, EARTH TAG,
ENTRY THREAD SEAL, SERRATED WASHER,
ADAPTOR/REDUCER
✝ Note : Gland size 20/16 suitable for Wire Braid Armour only.
Gland SizeMetric Minimum Cable Cable Braid/STA Across
OrderingPVC
Entry Thread Dia ‘A’ Dia ‘B’ Thickness CornersReference
Shroud
Thread ‘C’ Length ‘D’ Max Min Max Max Dia ‘E’ Max Ref.
20/16 * 20 15 8.6 6.0 13.4 0.85 24.4 20/16CX/Z PVC02
20S 20 10 11.6 9.5 15.9 0.85 26.6 20SCX/Z PVC04
20 20 10 13.9 12.5 20.9 0.9 33.3 20CX/Z PVC06
25 25 10 19.9 17.0 26.2 1.25 40.5 25CX/Z PVC09
32 32 10 26.2 22.9 33.9 1.4 51.0 32CX/Z PVC11
40 40 15 32.1 26.0 40.4 1.4 61.0 40CX/Z PVC15
50S 50 15 38.1 35.0 46.7 1.4 66.5 50SCX/Z PVC18
50 50 15 44.0 38.0 53.1 1.4 77.7 50CX/Z PVC21
63S 63 15 50.0 45.6 59.4 1.5 83.2 63SCX/Z PVC23
63 63 15 55.9 54.6 65.9 1.5 88.7 63CX/Z PVC25
75S 75 15 61.9 57.0 72.1 1.5 101.6 75SCX/Z PVC28
75 75 15 67.9 60.4 78.5 1.5 111.1 75CX/Z PVC30
90 90 15 79.3 69.2 90.4 1.6 128.6 90CX/Z PVC32
All Dimensions in Millimetres
A
B
C
D
E
-
8/17/2019 Cat-CMP Cable Gland
21/64
E1W GLAND
A R M O U R E D C A B
L E S W A
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
19
Brass indoor and outdoor cable gland for all types of SWA cable, providing
environmental seal on both the cable inner and outer sheaths.The gland also
provides mechanical cable retention and electrical continuity via armour wire
termination.
TECHNICAL DATA
TYPE E1W
DESIGN SPECIFICATION BSEN50262
INGRESS PROTECTION IP66
GLAND MATERIAL BRASS
SEAL MATERIAL CMP SOLO LSF
CABLE TYPE STEEL WIRE ARMOUR
ARMOUR CLAMPING TWO PART ARMOUR LOCK
(THREE PART OPTION AVAILABLE)
SEALING TECHNIQUE CMP DISPLACEMENT SEAL CONCEPT
SEALING AREA (S) INNER & OUTER SHEATH
OPTIONAL ACCESSORIES SHROUD, LOCKNUT, EARTH TAG
ENTRY THREAD SEAL, SERRATED WASHER
ADAPTOR/REDUCER
* Integral Entry Thread Seal Option Available
(for this option pre-fix gland type with ‘R’, e.g. 25RE1W)Also available in Brass with Nickel Plated finish.
Minimum Armour Across Ordering PVCGland Standard Entry Threads ‘C’
ThreadCable Dia ‘A’ Cable Dia ‘B’
Wire Corners Reference ShroudSize
Metric NPT PG Length ‘D’ Min Max Min Max Dia Dia ‘E’ Max (Metric) Ref.
20/16 20 1/2” PG11 15 3.1 8.6 6.0 13.4 0.9 24.4 20/16E1W PVC0220S 20 1/2” PG13.5 10 6.1 11.6 9.5 15.9 0.9/1.25 26.6 20SE1W PVC04
20 20 1/2” PG16 10 6.5 13.9 12.5 20.9 0.9/1.25 33.3 20E1W PVC06
25 25 3/4” PG21 10 11.1 19.9 17.0 26.2 1.25/1.6 40.5 25E1W PVC09
32 32 1” PG29 10 17.0 26.2 22.9 33.9 1.6/2.0 51.0 32E1W PVC11
40 40 1-1/4” PG36 15 22.0 32.1 26.0 40.4 1.6/2.0 61.0 40E1W PVC15
50S 50 1-1/2” PG36 15 29.5 38.1 35.0 46.7 2.0/2.5 66.5 50SE1W PVC18
50 50 2” PG42 15 35.6 44.0 38.0 53.1 2.0/2.5 77.7 50E1W PVC21
63S 63 2” PG48 15 40.1 49.9 45.6 59.4 2.5 83.2 63SE1W PVC23
63 63 2-1/2” - 15 47.2 55.9 54.6 65.9 2.5 88.7 63E1W PVC25
75S 75 2-1/2” - 15 52.8 61.9 57.0 72.1 2.5 101.6 75SE1W PVC28
75 75 3” - 15 59.1 67.9 60.4 78.5 2.5/3.15 111.1 75E1W PVC30
90 90 3” - 15 66.6 79.3 69.2 90.4 3.15 128.6 90E1W PVC32
All Dimensions in Millimetres
E1W Industrial Cable Gland
ADDITIONAL APPROVALS
MARINE APPROVALS LLOYDS,ABS
GOST CERTIFICATE OF CONFORMITY 5318856 REIW version colour coded with red
ferrule for ease of identification
A
B
C
D
E
-
8/17/2019 Cat-CMP Cable Gland
22/64
20
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
L E A D C O V E R E D A R M O U R E D C A B L E S W A
RE2W version colour coded with redferrule for ease of identification
E2W GLAND
Brass indoor and outdoor cable gland for all types of Lead Covered SWA
cable providing environmental seal on both the cable inner and outer sheaths.
The gland also provides mechanical cable retention, and electrical continuity
via armour wire termination and earth bonding of Lead Sheath.
TECHNICAL DATA
TYPE E2W
DESIGN SPECIFICATION BSEN50262
INGRESS PROTECTION IP66
GLAND MATERIAL BRASS
SEAL MATERIAL CMP SOLO LSF
CABLE TYPE LEAD COVERED STEEL WIRE ARMOUR
ARMOUR CLAMPING TWO PART ARMOUR LOCK
(THREE PART OPTION AVAILABLE)
SEALING TECHNIQUE CMP DISPLACEMENT SEAL CONCEPT
SEALING AREA (S) INNER & OUTER SHEATH
OPTIONAL ACCESSORIES SHROUD, LOCKNUT, EARTH TAG
ENTRY THREAD SEAL, SERRATED WASHER
ADAPTOR/REDUCER
* Integral Entry Thread Seal Option Available(for this option pre-fix gland type with ‘R’, e.g. 25RE2W)
Minimum Armour Across Ordering PVCGland Standard Entry Threads ‘C’
ThreadCable Dia ‘A’ Cable Dia ‘B’
Wire Corners Reference ShroudSize
Metric NPT PG Length ‘D’ Min Max Min Max Dia Dia ‘E’ Max (Metric) Ref.
20S 20 1/2” PG13.5 10 6.1 11.6 9.5 15.9 0.9/1.25 26.6 20SE2W PVC0420 20 1/2” PG16 10 6.5 13.9 12.5 20.9 0.9/1.25 33.3 20E2W PVC06
25 25 3/4” PG21 10 11.1 19.9 17.0 26.2 1.25/1.6 40.5 25E2W PVC09
32 32 1” PG29 10 17.0 26.2 22.9 33.9 1.6/2.0 51.0 32E2W PVC11
40 40 1-1/4” PG36 15 22.0 32.1 26.0 40.4 1.6/2.0 61.0 40E2W PVC15
50S 50 1-1/2” PG36 15 29.5 38.1 35.0 46.7 2.0/2.5 66.5 50SE2W PVC18
50 50 2” PG42 15 35.6 44.0 38.0 53.1 2.0/2.5 77.7 50E2W PVC21
63S 63 2” PG48 15 40.1 49.9 45.6 59.4 2.5 83.2 63SE2W PVC23
63 63 2-1/2” - 15 47.2 55.9 54.6 65.9 2.5 88.7 63E2W PVC25
75S 75 2-1/2” - 15 52.8 61.9 57.0 72.1 2.5 101.6 75SE2W PVC28
75 75 3” - 15 59.1 67.9 60.4 78.5 2.5/3.15 111.1 75E2W PVC30
90 90 3” - 15 66.6 79.3 69.2 90.4 3.15 128.6 90E2W PVC32
All Dimensions in Millimetres
E2W Industrial Cable Gland
ADDITIONAL APPROVALS
MARINE APPROVALS LLOYDS,ABS
GOST CERTIFICATE OF CONFORMITY 5318856
A
B
C
D
E
-
8/17/2019 Cat-CMP Cable Gland
23/64
B R A I D E D O R S T A
C A B L E
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
21
RE1X/Z version colour coded with redferrule for ease of identification
E1X/Z GLAND
Brass indoor and outdoor cable gland for all types of braided or steel tape
armour (S.T.A.) cables, providing environmental seal on both the cable inner
and outer sheaths.The gland also provides mechanical cable retention and
electrical continuity via wire braid or tape armour termination.
TECHNICAL DATA
TYPE E1X / Z
DESIGN SPECIFICATION BSEN50262
INGRESS PROTECTION IP66
GLAND MATERIAL BRASS
SEAL MATERIAL CMP SOLO LSF
CABLE TYPE WIRE BRAID OR STEEL TAPE ARMOUR
ARMOUR CLAMPING THREE PART ARMOUR LOCK
SEALING TECHNIQUE CMP DISPLACEMENT SEAL CONCEPT
SEALING AREA (S) INNER & OUTER SHEATH
OPTIONAL ACCESSORIES SHROUD, LOCKNUT, EARTH TAG
ENTRY THREAD SEAL, SERRATED WASHER
ADAPTOR/REDUCER
Minimum Braid Across Ordering PVCGland Standard Entry Threads ‘C’
ThreadCable Dia ‘A’ Cable Dia ‘B’
Thickness Corners Reference ShroudSize
Metric NPT PG Length ‘D’ Min Max Min Max Max Dia ‘E’ Max (Metric) Ref.
✝ 20/16 20 1/2” PG11 15 3.1 8.6 6.0 13.4 0.85 24.4 20/16E1X/Z PVC0220S 20 1/2” PG13.5 10 6.1 11.6 9.5 15.9 0.85 26.6 20SE1X/Z PVC04
20 20 1/2” PG16 10 6.5 13.9 12.5 20.9 0.9 33.3 20E1X/Z PVC06
25 25 3/4” PG21 10 11.1 19.9 17.0 26.2 1.25 40.5 25E1X/Z PVC09
32 32 1” PG29 10 17.0 26.2 22.9 33.9 1.4 51.0 32E1X/Z PVC11
40 40 1-1/4” PG36 15 22.0 32.1 26.0 40.4 1.4 61.0 40E1X/Z PVC15
50S 50 1-1/2” PG36 15 29.5 38.1 35.0 46.7 1.4 66.5 50SE1X/Z PVC18
50 50 2” PG42 15 35.6 44.0 38.0 53.1 1.4 77.7 50E1X/Z PVC21
63S 63 2” PG48 15 40.1 49.9 45.6 59.4 1.5 83.2 63SE1X/Z PVC23
63 63 2-1/2” - 15 47.2 55.9 54.6 65.9 1.5 88.7 63E1X/Z PVC25
75S 75 2-1/2” - 15 52.8 61.9 57.0 72.1 1.5 101.6 75SE1X/Z PVC28
75 75 3” - 15 59.1 67.9 60.4 78.5 1.5 111.1 75E1X/Z PVC30
90 90 3” - 15 66.6 79.3 69.2 90.4 1.6 128.6 90E1X/Z PVC32
All Dimensions in Millimetres
* Integral Entry Thread Seal Option Available
(for this option pre-fix gland type with ‘R’, e.g. 25RE1X/Z)Also available in Brass with Nickel Plated finish & Aluminium
✝ Note size 20/16 suitable for braid armour only.
E1X / Z Industrial Cable Gland
ADDITIONAL APPROVALS
MARINE APPROVALS LLOYDS,ABS
GOST CERTIFICATE OF CONFORMITY 5318856
D
A
B
C
E
-
8/17/2019 Cat-CMP Cable Gland
24/64
22
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
A R M O U R E D C A B
L E A W A
D
A
B
C
E
CW AL GLAND
Aluminium indoor and outdoor cable gland for all types of AWA cable,
providing environmental seal on the cable outer sheath.The gland also
provides mechanical cable retention and electrical continuity via armour
wire termination.
TECHNICAL DATA
TYPE CW ALUMINIUM
DESIGN SPECIFICATION BSEN50262
INGRESS PROTECTION IP66
GLAND MATERIAL ALUMINIUM
SEAL MATERIAL CMP SOLO LSF
CABLE TYPE ALUMINIUM WIRE ARMOUR
ARMOUR CLAMPING TWO PART ARMOUR LOCK
SEALING TECHNIQUE CMP DISPLACEMENT SEAL CONCEPT
SEALING AREA (S) OUTER SHEATH
OPTIONAL ACCESSORIES SHROUD, LOCKNUT, EARTH TAG
ENTRY THREAD SEAL, SERRATED WASHER
ADAPTOR/REDUCER
Gland SizeMetric Minimum Cable Cable Armour Across Ordering PVC
Entry Thread Dia ‘A’ Dia ‘B’ Wire Corners Reference Shroud
Thread ‘C’ Length ‘D’ Max Min Max Dia Dia ‘E’ Max (Gland Only) Ref.
20S 20 10 11.6 9.5 15.9 0.9/1.25 26.6 20SCW AL PVC04
20 20 10 13.9 12.5 20.9 0.9/1.25 33.3 20CW AL PVC06
25 25 10 19.9 17.0 26.2 1.25/1.6 40.5 25CW AL PVC09
32 32 10 26.2 22.9 33.9 1.6/2.0 51.0 32CW AL PVC11
40 40 15 32.1 26.0 40.4 1.6/2.0 61.0 40CW AL PVC15
50S 50 15 38.1 35.0 46.7 2.0/2.5 66.5 50SCW AL PVC18
50 50 15 44.0 38.0 53.1 2.0/2.5 78.6 50CW AL PVC21
63S 63 15 50.0 45.6 59.4 2.5 83.2 63SCW AL PVC23
63 63 15 55.9 54.6 65.9 2.5 89.0 63CW AL PVC25
75S 75 15 61.9 57.0 72.1 2.5 101.6 75SCW AL PVC28
All Dimensions in Millimetres
CW Aluminium Industrial Cable Gland
ADDITIONAL APPROVALS
GOST CERTIFICATE OF CONFORMITY 5318856
-
8/17/2019 Cat-CMP Cable Gland
25/64
APPL ICAT ION
The CMP range of Hazardous Area Cable Glands offers the user solutions which are highly cost effective in their design, and installation process. The
CMP philosophy of delivering client and end user specific requirements can beseen from a number of significant developments in this range. Given the level
of experience gained in this field CMP are able to provide a high degree of technical support and advice on the use of cable Glands in Hazardous Area
applications
PRODUCTS
Cable Gland options for all types of cable.
SPECIFICATIONS & APPROVALS
Derived from the BS6121 standard which was the original ‘flameproof’standard for Cable Glands CMP Hazardous Area Cable Glands comply with
a number of international standards including CENELEC (EN50014 & EN60079), IEC (IEC 79) UL & CSA.
CMP PRODUCTS
RANGE FOR IEC TYPE CABLES
‘© BP Amoco p.l.c. 1997
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
-
8/17/2019 Cat-CMP Cable Gland
26/64
24
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
Dual Certified Flameproof (Type 'd') and Increased Safety (Type 'e') indoor and
outdoor cable gland for use in Zone 1,Zone 2, Zone 21 and Zone 22 Hazardous
Areas with all types of unarmoured cable, providing a Flameproof seal on the cable
outer sheath.
TECHNICAL DATA
TYPE A2F
CENELEC (ATEX) CERTIFICATION SIRA02ATEX1057X
CODE OF PROTECTION CATEGORY ATEX II 2 GD EEx d IIC & EEx e II,
EQUIPMENT ZONE 1,ZONE 2, ZONE 21, &
ZONE 22 - GAS GROUPS IIA, IIB, IIC
COMPLIANCE STANDARDS EN50014,EN50018,EN50019,EN50281-1-1
CONTINUOUS OPERATING TEMP.RANGE -60°C TO +130°C
INGRESS PROTECTION IP66, IP67 & IP68 (10M DEPTH)
DELUGE PROTECTION TO DTS 01:1991
GLAND MATERIAL BRASS
SEAL MATERIAL CMP SOLO LSFCABLE TYPE UNARMOURED
SEALING TECHNIQUE CMP DISPLACEMENT SEAL CONCEPT
SEALING AREA(S) OUTER SHEATH
OPTIONAL ACCESSORIES SHROUD, LOCKNUT, EARTH TAG,
ENTRY THREAD SEAL, SERRATED WASHER,
ADAPTOR/REDUCER
Minimum Across Ordering PVC
Gland SizeStandard Entry Threads ‘B’
ThreadCable Dia ‘A’
Corners Reference Shroud
Metric NPT PG Length ‘C’ Min Max Dia ‘D’ Max (Metric) Ref.
16 16 1/2” PG11 15 3.1 8.6 24.4 16A2F PVC0120/16 20 1/2” PG11 15 3.1 8.6 24.4 20/16A2F PVC01
20S 20 1/2” PG13.5 15 6.1 11.6 26.5 20SA2F PVC03
20 20 1/2” PG16 15 6.5 13.9 30.0 20A2F PVC05
25 25 3/4” PG21 15 11.1 19.9 39.9 25A2F PVC08
32 32 1” PG29 15 17.0 26.2 45.5 32A2F PVC10
40 40 1-1/4” PG36 15 22.0 32.1 55.4 40A2F PVC12
50S 50 1-1/2” PG36 15 29.5 38.1 61.0 50SA2F PVC14
50 50 2” PG42 15 35.6 44.0 66.5 50A2F PVC17
63S 63 2” PG48 15 40.1 49.9 77.6 63SA2F PVC20
63 63 2-1/2” - 15 47.2 55.9 83.2 63A2F PVC22
75S 75 2-1/2” - 15 52.8 61.9 88.7 75SA2F PVC24
75 75 3” - 15 59.1 67.9 94.2 75A2F PVC26
90 90 3” - 15 66.6 79.3 120.7 90A2F PVC31
All Dimensions in Millimetres
A
B
C
D
A2F Flameproof EEx d & Increased Safety EEx e Cable Gland A2F GLAND
ADDITIONAL APPROVALS
MARINE APPROVALS LLOYDS, DNV,ABS
CSA APPROVAL 1211841
CEPEL/INMENRD APPROVAL EX-023
SAQAS APPROVAL AUS EX764
GOST APPROVAL 2002 . C256
* Integral Entry Thread Seal Option Available(for this option pre-fix gland type with ‘R’, e.g. 25RA2F)Also available in Brass with Nickel Plated finish, Stainless Steel & Aluminium
U N A R M O U R E D
C A B L E
-
8/17/2019 Cat-CMP Cable Gland
27/64
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
25
U N A R M O U R E D
C A B L E
Sureseal 2000 (SS2K) EEx ‘d’ & EEx ‘e’ Cable Gland SS2K GLAND
Flameproof (Type ‘d’) and Increased Safety (Type ‘e’) Brass Cable Gland for all
types of Unarmored Cables.This Cable Gland provides an explosion proof seal on
the cable inner or outer sheath and a secondary environmental seal on the cable
outer sheath. Suitable for use in Zone 1 and 2 Hazardous Areas, this Cable Gland
design affords extra stability and superior resistance to cable pull out.Type SS2KPBavailable for unarmoured cables with lead sheath.
TECHNICAL DATA
A
B
C
D
E
TYPE SS2K (SS2KPB FOR LEAD SHEATHED CABLES)
CERTIFICATION DETAIL SIRA 02ATEX1057X
CODE OF PROTECTION CATEGORY ATEX II 2 GD EEx d IIC & EEx e II,
Equipment Zone 1, Zone 2, Zone 21,
& Zone 22 - Gas Groups IIA, IIB, IIC
COMPLIANCE CODE EN50014:1997, EN50018:2000,
EN50019:2000, EN50281-1-1:1998
TEMPERATURE RATING
(CONT. OPERATION) -60°C TO +130°C
INGRESS PROTECTION IP66, IP67 & IP68 (DEPTH OF 10M)
DELUGE PROTECTION TO DTS 01:91
GLAND MATERIAL BRASS
SEAL MATERIAL LSF THERMOPLASTIC ELASTOMER
CABLE TYPE UNARMOURED
SEALING TECHNIQUE CMP DISPLACEMENT SEAL CONCEPT
SEALING AREA(S) OUTER SHEATH (DOUBLE SEAL)
OPTIONAL ACCESSORIES LOCKNUT,EARTH TAG, SERRATED
WASHER, ENTRY THREAD SEAL,
ADAPTOR/REDUCER
Integral Entry Thread Seal Option Available (for this option pre-fix glandtype with ‘R’ e.g. 25RSS2K).
Standard Entry Minimum Cable Dia ‘A’ / ‘B’ Across OrderingGland Threads ‘C’ Thread Millimetres Corners ReferenceSize
Metric NPT PG Length ‘D’ Min Max Dia ‘E’ Max (Metric)
16 16 1/2” PG11 15 3.1 8.6 24.4 16SS2K20/16 20 1/2” PG11 15 3.1 8.6 24.4 20/16SS2K
20S 20 1/2” PG13.5 15 6.1 11.6 26.5 20SSS2K
20 20 1/2” PG16 15 6.5 13.9 30.0 20SS2K
25 25 3/4” PG21 15 11.1 19.9 39.9 25SS2K
32 32 1” PG29 15 17.0 26.2 45.5 32SS2K
40 40 1-1/4” PG36 15 22.0 32.1 55.4 40SS2K
50S 50 1-1/2” PG36 15 29.5 38.1 61.0 50SSS2K
50 50 2” PG42 15 35.6 44.0 66.5 50SS2K
63S 63 2” PG48 15 40.1 49.9 77.6 63SSS2K
63 63 2-1/2” - 15 47.2 55.9 83.2 63SS2K
75S 75 2-1/2” - 15 52.8 61.9 88.7 75SSS2K
75 75 3” - 15 59.1 67.9 94.2 75SS2K90 90 3” - 15 66.6 79.3 120.7 90SS2K
All Dimensions in Millimetres
-
8/17/2019 Cat-CMP Cable Gland
28/64
w w w . c m p – p r o d u c t s . c o m
U N A R M O U R E D C A B L E
( C O N D U I T )
Doc Ref : TPC 164 issue 04 2005
Minimum ✝ Standard AcrossOrderingGland Standard Entry Threads ‘B’
Thread FemaleCable Dia ‘A’
CornersReferenceSize
Metric NPT PG Length ‘C’ NPT Threads Min Max Dia ‘D’ Max
20/16 20 1/2” PG11 15 1/2” 3.1 8.6 30.0 20/16A2FRC20S 20 1/2” PG13.5 15 1/2” 6.1 11.6 30.0 20SA2FRC
20 20 1/2” PG16 15 1/2” 6.5 13.9 30.0 20A2FRC
25 25 3/4” PG21 15 3/4” 11.1 19.9 39.9 25A2FRC
32 32 1” PG29 15 1” 17.0 26.2 45.5 32A2FRC
40 40 1-1/4” PG36 15 1-1/4” 22.0 32.1 55.4 40A2FRC
50S 50 1-1/2” PG36 15 1-1/2” 29.5 38.1 61.0 50SA2FRC
50 50 2” PG42 15 2” 35.6 44.0 72.1 50A2FRC
63S 63 2” PG48 15 2” 40.1 49.9 77.6 63SA2FRC
63 63 2-1/2” - 15 2-1/2” 47.2 55.9 88.7 63A2FRC
75S 75 2-1/2” - 15 2-1/2” 52.8 61.9 88.7 75SA2FRC
75 75 3” - 15 3” 59.1 67.9 105.3 75A2FRC
90 90 3” - 15 3” 66.6 79.3 120.7 90A2FRC
All Dimensions in Millimetres
✝ Female connection threads in NPT, other thread forms manufactured to order. When ordering please confirm Male & Female Threads required.
A
B
C
D
A2FRC GLAND
3426
A2FRC Flameproof EEx d & Increased Safety EEx e Cable Gland
Also available in Brass with Nickel Plated finish
Dual Certified Flameproof (Type 'd') and Increased Safety (Type 'e') indoor and
outdoor cable gland for use in Zone 1,Zone 2, Zone 21 and Zone 22 Hazardous
Areas with all types unarmoured cable housed in rigid or flexible conduit system.
The cable gland provides a Flameproof Seal on the cable outer sheath and is
equipped with a rotating female connection for ease of conduit installation.
TECHNICAL DATA
TYPE A2FRC
DETAIL SIRA02ATEX1057X
CODE OF PROTECTION CATEGORY ATEX II 2 GD EEx d IIC & EEx e II,
EQUIPMENT ZONE 1,ZONE 2, ZONE 21,
& ZONE 22 - GAS GROUPS IIA, IIB, IIC
COMPLIANCE S TANDARDS EN50014, EN50018, EN50019, EN50281-1-1
CONTINUOUS OPERATING TEMP RANGE -60ºC TO +130ºC
INGRESS PROTECTION IP66, IP67 & IP68 (10M DEPTH)
GLAND MATERIAL BRASS
SEAL MATERIAL CMP SOLO LSF
CABLE TYPE UNARMOURED
SEALING TECHNIQUE CMP DISPLACEMENT SEAL CONCEPT
SEALING AREA(S) OUTER SHEATH
OPTIONAL ACCESSORIES LOCKNUT, EARTH TAG, SERRATED WASHER
ENTRY THREAD SEAL,ADAPTOR/REDUCER
ADDITIONAL APPROVALS
MARINE APPROVALS LLOYDS,ABS
GOST APPROVAL 2002 . C256
-
8/17/2019 Cat-CMP Cable Gland
29/64
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
V-Tec (A2Pe) For Hazazrdous Locations
CMP V-TEC EX M Cable Glands (A2Pe) - Code of protection EEx e II
*Sealing range based upon strain relief & twist protection to VDE 0619 - Available colours: Black, Light Grey (RAL 7001) & Silver Grey (RAL 7035).For colour options please add the folowing suffix to the ordering codes above:B= Black. G= Light Grey. S= Silver GreyOther colours and other non-metallic products in the V-TEC range are also available, please consult CMP Products for further information.
A2XPI / A2XLP1 PG 7 8.0 15.0 3.5 6.5 18.0 23.0 15.0 16.5 0.41 50
A2XP2 / A2XLP2 PG 9 8.0 15.0 5.0 8.0 21.0 27.0 19.0 21.0 0.67 50
A2XP3 / A2XLP3 PG 11 8.0 15.0 4.5 10.0 22.0 29.0 22.0 25.0 0.93 50
A2XP4 / A2XLP4 PG 13.5 9.0 15.0 6.5 12.0 22.0 30.0 24.0 27.0 1.09 50
A2XP5 / A2XLP5 PG 16 10.0 15.0 7.0 14.0 25.0 33.0 27.0 30.0 1.49 25
A2XP6 / A2XLP6 PG 21 11.0 15.0 12.0 18.0 28.0 38.0 33.0 37.5 2.33 25
A2XP7 / A2XLP7 PG 29 11.0 15.0 17.0 25.0 32.0 43.0 42.0 47.5 3.86 20
A2XP9 / A2XLP9 PG 42 13.0 18.0 24.0 38.0 42.0 57.0 60.0 68.5 10.07 5
A2XP10 / A2XLP10 PG 48 14.0 18.0 30.0 44.0 42.0 58.0 65.0 74.0 10.73 5
CMP V-TEC EX & EX L Cable Glands (A2Pe) - Code of protection EEx e II
Size Ref.ThreadSize ‘A’
Thread Length ‘B’
EX EX L
Cable AcceptanceRange ‘C’
Min Max
Overall Length ‘D’
Min Max
AcrossFlats
AcrossCorners
Weight(KG/100)
Pack QTY.
A2XMP1 M12 8.0 3.5 6.5 18.0 23.0 15.0 16.5 0.36 50
A2XMP2 M16 8.0 5.0 8.0 21.0 27.0 19.0 21.0 0.63 50
A2XMP3 M20 9.0 7.0 12.0 23.0 30.0 24.0 27.0 1.00 50
A2XMP4 M25 11.0 12.0 18.0 28.0 38.0 33.0 37.5 2.35 25
A2XMP5 M32 11.0 17.0 25.0 32.0 43.0 42.0 47.5 3.90 20
Size Ref.ThreadSize ‘A’
Cable AcceptanceRange ‘C’
Min Max
Overall Length ‘D’AcrossFlats
AcrossCorners
Weight(KG/100)
Pack QTY.
ThreadLength ‘B’
Min Max
TYPE DESIGNATION V-TEC, EX L & EX M (A2PE)
CLASSIFICATION,HAZARDOUS AREA II 2G EEX E II
COMPLIANCE CODE EN50014 & EN50019
CENELEC CERTIFICATION PTB 99 ATEX 3112X & ATEX 3113X
UL LISTING EI70293
CABLE GLAND MATERIAL PA POLYAMIDE, (COLOUR BLACK)
SEAL MATERIAL CMP SOLO LSF
FLAME RETARDANCY SPECIFICATION VDE 0471/IEC 695 PART 2-1
WITHSTAND TEMPERATURE TESTED +750˚C
CONTINUOUS OPERATING -20˚C TO +70˚CTEMPERATURE RANGE
INGRESS PROTECTION IP68(AT 5 BAR) TO VDE 0619 / IEC529
CABLE TYPE UNARMOURED
SEALING AREA OUTER SHEATH
SEALING TECHNIQUE CONTROLLED SEAL WITH STRAIN RELIEF
OPTIONAL ACCESSORIES LOCKNUT, ADAPTOR / REDUCER
TECHNICAL DATA
Plastic gland for use with unarmoured cables.
U N A R M O U R E D C A B L E S
27
-
8/17/2019 Cat-CMP Cable Gland
30/64
A4e Increased Safety EEx e Cable Gland
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
A R M O U R E D C A B
L E S T A
28
TYPE A4e
CERTIFICATION DETAIL SIRA02ATEX1057X
CODE OF PROTECTION CATEGORY ATEX II 2 GD EEx e II, Equipment
Zone 1, Zone 2, Zone 21,& Zone 22 - Gas
Groups IIA, IIB, IIC
COMPLIANCE CODE EN50014:1997, EN50019:2000,
EN50281-1-1:1998
CONTINUOUS OPERATING
TEMPERATURE RANGE -60°C TO +130°C
INGRESS PROTECTION IP66
GLAND MATERIAL BRASS
SEAL MATERIAL LSF THERMOPLASTIC ELASTOMER
CABLE TYPE STEEL TAPE ARMOUR
ARMOUR TERMINATION LEAD CONTINUITY SEAL
SEALING TECHNIQUE CMP DISPLACEMENT SEAL CONCEPT
SEALING AREA (S) OUTER SHEATH
OPTIONAL ACCESSORIES SHROUD, LOCKNUT, EARTH TAG,
ENTRY THREAD SEAL, SERRATED WASHER
ADAPTOR/REDUCER
* SOLO Option with LSF Shrouds also Available.
A
B
C
D
E
A4e GLAND
Brass indoor and outdoor cable gland for use in Zone 1 and Zone 2 Hazardous Areas
with all types of steel tape armour cable, providing a seal on the cable outer sheath,
and an electrical earth continuity seal on the Tape Armour.
TECHNICAL DATA
Minimum Across Ordering PVC
Gland SizeStandard Entry Threads ‘C’
ThreadCable Dia ‘A’ Cable Dia ‘B’
Corners Reference Shroud
Metric NPT PG Length ‘D’ Min Max Min Max Dia ‘E’ Max (Metric) Ref.
20S 20 1/2” PG13.5 15 6.5 11.6 6.1 11.6 26.5 20SA4e PVC0420 20 1/2” PG16 15 10.0 13.9 6.5 13.9 30.0 20A4e PVC05
25 25 3/4” PG21 15 11.6 19.9 11.1 19.9 39.9 25A4e PVC09
32 32 1” PG29 15 19.0 26.2 17.0 26.2 45.5 32A4e PVC10
40 40 1-1/4” PG36 15 25.0 32.1 22.0 32.1 55.4 40A4e PVC13
50S 50 1-1/2” PG36 15 27.5 38.1 29.5 38.1 61.0 50SA4e PVC15
50 50 2” PG42 15 33.1 44.0 35.6 44.0 66.5 50A4e PVC18
63S 63 2” PG48 15 40.1 50.0 40.1 49.9 77.6 63SA4e PVC21
63 63 2-1/2” - 15 47.2 55.9 47.2 55.9 83.2 63A4e PVC23
75S 75 2-1/2” - 15 43.5 61.9 52.8 61.9 88.7 75SA4e PVC24
75 75 3” - 15 49.8 67.9 59.1 67.9 94.2 75A4e PVC26
90 90 3” - 15 64.0 79.3 66.6 79.3 120.7 90A4e PVC31
All Dimensions are in Millimetres
-
8/17/2019 Cat-CMP Cable Gland
31/64
w w w . c m p – p r o d u c t s . c o m
3429
M U L T I P L E A R M O U
R C A B L E S
Doc Ref : TPC 164 issue 04 2005
Increased Safety (Type 'e') Deluge Proof cable gland for all types of armoured cables
including Single Wire Armour (SWA), Steel Tape Armour (STA) and Braided cables.This
cable gland provides an environmental seal on the cable outer sheath and incorporates
an enclosed 'O' ring seal for deluge protection which has been independently tested to
DTS 01:1991.The gland also provides mechanical cable retention and earth continuity
via armour termination. Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22
Hazardous Areas in Increased Safety (type 'e') apparatus or EEx de equipment which
has an increased safety terminal chamber.
TECHNICAL DATA
TYPE C2K
DETAIL SIRA01ATEX3283X
COMPLIANCE STANDARDS EN50014,EN50019, EN50281-1-1
COMPLIANCE STANDARDS ATEX II 2 GD EEx e II, EQUIPMENT ZONE 1,ZONE 2,
ZONE 21, & ZONE 22 - GAS GROUPS IIA, IIB, IIC
CONTINUOUS OPERATING
TEMPERATURE RATING -60°C TO +130°CINGRESS PROTECTION IP66, I P67, I P68 (10M DEPTH)
DELUGE PROTECTION TO DTS 01: 1991
GLAND MATERIAL BRASS
SEAL MATERIAL CMP SOLO LSF
CABLE TYPE STEEL WIRE, STEEL TAPE OR WIRE BRAID ARMOUR
ARMOUR CLAMPING REVERSIBLE ARMOUR CONE
SEALING TECHNIQUE CMP DISPLACEMENT SEAL CONCEPT
SEALING AREA (S) OUTER SHEATH
OPTIONAL ACCESSORIES LOCKNUT, EARTH TAG, ENTRY THREAD SEAL
SERRATED WASHER, ADAPTOR/REDUCER
✝ For IP67 & IP68 requirements the cable diameter ‘B’ (minimum value) shown above should be increased by 1.0mm to ensure compliance.
C2K Increased Safety EEx e Cable Gland
ADDITIONAL APPROVALS
MARINE APPROVALS LLOYDS, DNV,ABS
GOST APPROVAL 2002 . C256
C2K GLAND
Standard Entry Minimum Cable Dia ‘A’ ✝ Cable Dia ‘B’ Armour Range Across OrderingGland Threads ‘C’ Thread (mm) (mm) Grooved Cone Plain Cone Corners ReferenceSize
Metric NPT Length ‘D’ Max Min Max Min Max Min Max ‘E’ Max (Metric)
20/16 20 1/2” 15 8.6 6.0 13.4 0 1.0 0.9 1.0 24.4 20/16C2K20S 20 1/2” 15 11.6 9.5 15.9 0 1.0 0.9 1.25 26.6 20SC2K
20 20 1/2” 15 13.9 12.5 20.9 0 1.0 0.9 1.25 33.3 20C2K
25 25 3/4” 15 19.9 17.0 26.2 0 1.0 1.25 1.6 40.5 25C2K
32 32 1” 15 26.2 22.9 33.9 0 1.0 1.6 2.0 51.0 32C2K
40 40 1-1/4” 15 32.1 26.0 40.4 0 1.0 1.6 2.0 61.0 40C2K
50S 50 1-1/2” 15 38.1 35.0 46.7 0 1.0 2.0 2.5 66.5 50SC2K
50 50 2” 15 44.0 38.0 53.1 0 1.0 2.0 2.5 77.7 50C2K
63S 63 2” 15 50.0 45.6 59.4 0 1.0 2.5 2.5 83.2 63SC2K
63 63 2-1/2” 15 55.9 54.6 65.9 0 1.0 2.5 2.5 88.7 63C2K
75S 75 2-1/2” 15 61.9 57.0 72.1 0 1.0 2.5 2.5 101.6 75SC2K
75 75 3” 15 67.9 60.4 78.5 0 1.0 2.5 2.5 111.1 75C2K
90 90 3-1/2” 15 79.3 69.2 90.4 0 1.6 2.5 2.5 128.6 90C2K
All Dimensions are in Millimetres
D
A
B
C
E
-
8/17/2019 Cat-CMP Cable Gland
32/64
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
Increased Safety (Type 'e') indoor and outdoor cable gland for use in Zone 1, Zone 2,
Zone 21 and Zone 22 Hazardous Areas with all types of SWA cable providing an
environmental seal on the cable outer sheath.The cable gland also provides mechanical
cable retention and earth continuity via armour wire termination. Suitable for use in
conjunction with Increased Safety (type 'e') apparatus or EEx de equipment which has
an increased safety terminal chamber.
TECHNICAL DATA
TYPE CWe
DETAIL SIRA01ATEX3287X
CODE OF PROTECTION CATEGORY ATEX II 2 GD EEx e II, EQUIPMENTZONE 1, ZONE 2, ZONE 21,& ZONE 22 -GAS GROUPS IIA, IIB, IIC
COMPLIANCE STANDARDS EN50014, EN50019, EN50281-1-1
CONTINUOUS OPERATINGTEMPERATURE RANGE -60°C TO +130°C
INGRESS PROTECTION IP66
GLAND MATERIAL BRASS
SEAL MATERIAL CMP SOLO LSF
CABLE TYPE STEEL WIRE ARMOUR
ARMOUR CLAMPING TWO PART ARMOUR LOCK(THREE PART OPTION AVAILABLE).
SEALING TECHNIQUE CMP DISPLACEMENT SEAL CONCEPT
SEALING AREA (S) OUTER SHEATH
OPTIONAL ACCESSORIES SHROUD, LOCKNUT, EARTH TAG,ENTRY THREAD SEAL, SERRATED WASHERADAPTOR/REDUCER
* CMP SOLO Option with LSF Shrouds also Available.
Also available in Brass with Nickel Plated finish and Aluminium
CWe Increased Safety EEx e Cable GlandCWe GLAND
ADDITIONAL APPROVALS
MARINE APPROVALS LLOYDS,ABS
GOST APPROVAL 2002 . C256
ANZEX APPROVAL ANZEX 03. 3000-0
Gland SizeMetric Minimum Cable Cable Armour Across
OrderingPVC
Entry Thread Dia ‘A’ Dia ‘B’ Wire CornersReference
Shroud
Thread ‘C’ Length ‘D’ Max Min Max Dia Dia ‘E’ Max Ref.
20/16 20 15 8.6 6.0 13.4 0.9 24.4 20/16CWe PVC02
20S 20 15 11.6 9.5 15.9 0.9/1.25 26.6 20SCWe PVC04
20 20 15 13.9 12.5 20.9 0.9/1.25 33.3 20CWe PVC06
25 25 15 19.9 17.0 26.2 1.25/1.6 40.5 25CWe PVC09
32 32 15 26.2 22.9 33.9 1.6/2.0 51.0 32CWe PVC11
40 40 15 32.1 26.0 40.4 1.6/2.0 61.0 40CWe PVC15
50S 50 15 38.1 35.0 46.7 2.0/2.5 66.5 50SCWe PVC18
50 50 15 44.0 38.0 53.1 2.0/2.5 78.6 50CWe PVC21
63S 63 15 50.0 45.6 59.4 2.5 83.2 63SCWe PVC23
63 63 15 55.9 54.6 65.9 2.5 89.0 63CWe PVC25
75S 75 15 61.9 57.0 72.1 2.5 101.6 75SCWe PVC28
75 75 15 67.9 60.4 78.5 2.5/3.15 111.1 75CWe PVC30
All Dimensions in Millimetres
A R M O U R E D C A B L E S S W A
30
D
A
B
C
E
-
8/17/2019 Cat-CMP Cable Gland
33/64
w w w . c m p – p r o d u c t s . c o m
3431
Doc Ref : TPC 164 issue 04 2005
B R A I D E D
O R S T A
C A B L E
CXe GLAND
Increased Safety (Type 'e') indoor and outdoor cable gland for use in Zone 1, Zone 2,
Zone 21 and Zone 22 Hazardous Areas with all types of braided cable or STA cables
providing an environmental seal on the cable outer sheath.The gland also provides
mechanical cable retention and electrical continuity via armour termination. Suitable
for use in conjunction with Increased Safety (type 'e') apparatus or EEx de equipment
which has an increased safety terminal chamber.
TECHNICAL DATA
TYPE CXe
DETAIL SIRA01ATEX3287X
CODE OF PROTECTION CATEGORY ATEX II 2 GD EEx e II, EQUIPMENTZONE 1, ZONE 2, ZONE 21, & ZONE 22-GAS GROUPS IIA, IIB, IIC
COMPLIANCE STANDARDS EN50014, EN50019, EN50281-1-1
CONTINUOUS OPERATINGTEMPERATURE RANGE -60°C TO +130°C
INGRESS PROTECTION IP66
GLAND MATERIAL BRASS
SEAL MATERIAL CMP SOLO LSF
CABLE TYPE WIRE BRAID OR STA ARMOUR
ARMOUR CLAMPING THREE PART ARMOUR LOCK
SEALING TECHNIQUE CMP DISPLACEMENT SEAL CONCEPT
SEALING AREA OUTER SHEATH
OPTIONAL ACCESSORIES SHROUD, LOCKNUT, EARTH TAG,ENTRY THREAD SEAL, SERRATED WASHERADAPTOR/REDUCER
* CMP SOLO Option with LSF Shrouds also Available.
Also available in Brass with Nickel Plated finish
CXe Increased Safety EEx e Cable Gland
ADDITIONAL APPROVALS
MARINE APPROVALS LLOYDS,ABS
GOST APPROVAL 2002 . C256
ANZEX APPROVAL ANZEX 03. 3000-0
Gland SizeMetric Minimum Cable Cable Braid Across
OrderingPVC
Entry Thread Dia ‘A’ Dia ‘B’ Thickness CornersReference
Shroud
Thread ‘C’ Length ‘D’ Max Min Max Max Dia ‘E’ Max Ref.
20/16 20 15 8.6 6.0 13.4 0.85 24.4 20/16CXe PVC02
20S 20 15 11.6 9.5 15.9 0.85 26.6 20SCXe PVC04
20 20 15 13.9 12.5 20.9 0.9 33.3 20CXe PVC06
25 25 15 19.9 17.0 26.2 1.25 40.5 25CXe PVC09
32 32 15 26.2 22.9 33.9 1.4 51.0 32CXe PVC11
40 40 15 32.1 26.0 40.4 1.4 61.0 40CXe PVC15
50S 50 15 38.1 35.0 46.7 1.4 66.5 50SCXe PVC18
50 50 15 44.0 38.0 53.1 1.4 78.6 50CXe PVC21
63S 63 15 50.0 45.6 59.4 1.5 83.2 63SCXe PVC23
63 63 15 55.9 54.6 65.9 1.5 89.0 63CXe PVC25
75S 75 15 61.9 57.0 72.1 1.5 101.6 75SCXe PVC28
75 75 15 67.9 60.4 78.5 1.5 111.1 75CXe PVC30
All Dimensions in Millimetres
A
B
C
D
E
-
8/17/2019 Cat-CMP Cable Gland
34/64
w w w . c m p – p r o d u c t s . c o m
Doc Ref : TPC 164 issue 04 2005
T3CDS Cable Gland
* For IP67 & IP68 requirements the Cable Diameter ‘B’ (minimum value) shown should be increased by 1.0mm to ensure complete compliance
TRITON CDS (Compensating Displacement seal) T3CDS Flameproof EEx d andIncreased Safety EEx e brass cable gland for all types of armoured & braided cableincluding lead sheathed versions, providing a Flameproof seal on the cable inner sheathand an environmental seal on the cable outer sheath.Equipped with a unique ReversibleArmour Cone and Bi-Directional Armour Clamping Ring which can accommodate SWA,braided and STA cables. The Cable Gland provides mechanical cable retention, and
electrical continuity via armour termination. Suitable for use in Zone 1, Zone 2,Zone 21and Zone 22 Hazardous Areas.
20/16 M20 1/2” PG 11 15 3.1 8.6 6 13.4 0 1 0.9 1.25 24.4 22 74 20/16T3CDS POSPVC02
20S M20 1/2” PG13.5 15 6.1 11.6 9.5 15.9 0 1 0.9 1.25 26.6 24 70 20ST3CDS POSPVC04
20 M20 1/2” PG16 15 6.5 13.9 12.5 20.9 0 1 0.9 1.25 33.3 30.5 74 20T3CDS POSPVC06
25 M25 3/4” PG21 15 11.1 19.9 18 26.2 0 1 1.25 1.6 40.5 37.5 82 25T3CDS POSPVC09
25S M25 3/4” PG21 15 11.1 19.9 14 22 0 1 1.25 1.6 40.5 37.5 82 25ST3CDS POSPVC09
32 M32 1” PG29 15 17 26.2 22.9 33.9 0 1 1.6 2 51 46 82 32ST3CDS POSPVC11
40 M40 1-1/4” PG36 15 22 32.1 26 40.4 0 1 1.6 2 61 55 85 40T3CDS POSPVC15
50S M50 1-1/2” PG36 15 29.5 38.1 35 46.7 0 1 2 2.5 66.5 60 93 50ST3CDS POSPVC18
50 M50 2” PG42 15 35.6 44 38 53.1 0 1 2 2.5 78.6 70.1 98 50T3CDS POSPVC21
63S M63 2” PG48 15 40.1 49.9 45.6 59.4 0 1 2.5 2.5 83.2 75 100 63ST3CDS POSPVC23
63 M63 2-1/2” - 15 47.2 55.9 54.6 65.9 0 1 2.5 2.5 89 80 100 63T3CDS POSPVC25
75S M75 2-1/2” - 15 52.8 60.5 57 72.1 0 1 2.5 2.5 101.6 90 100 75ST3CDS POSPVC28
75 M75 3” - 15 59.1 67.9 60.4 78.5 0 1 2.5 2.5 111.1 100 110 75T3CDS POSPVC30
90 M90 3-1/2” - 15 66.6 79.3 69.2 90.4 0 1 2.5 2.5 127.5 115 135 90T3CDS POSPVC32
GlandSize
Min.ThreadLength
‘D’
AcrossCorners
‘E’
AcrossFlats‘F’
OrderingReference
PVCShround
Reference
InstalledLength
Protrusion‘G’
Entry Threads ‘C’
Standard Optional
Cable Dia‘A’
Cable Dia‘B’ Armour Range
Metric NPT PG Min Max Max Max MaxGrooved Cone Plain ConeMin Max
TRITON CDS (T3CDS)
Triton CDS delivers a unique concept in cable sealing techniques incorporatingthe patented Compensating Displacement Seal system, CDS
INNER FLAMEPROOF SEAL• Unique new Compensating Displacement Seal (CDS) system, compatible with all
types of cable (eliminates cable damage and cold flow)• At the critical cable sealing point the CDS system protects the cable inner sheath
from any excess force, which is transferred to and absorbed by the internalcompensator incorporated in the CDS system
• Allows the Cable Gland to be tightened face to face every time regardlessof cable diameter.
TECHNICAL DATA
TYPE DESIGNATION T3CDS (T3CDS PB FOR LEAD SHEATHED CABLES)
CODE OF PROTECTION CATEGORY ATEX II 2 GD EEx d IIC & EEx e II,
COMPLIANCE STANDARDS EN50014,EN50018, EN50019 & EN50281-1-1:1998
CONTINUOUS OPERATINGTEMPERATURE RANGE -60°C TO +130°C
INGRESS PROTECTION IP66, I P67, I P68 & DTS 01:1991
DELUGE PROTECTION TO DTS 01:1991
STANDARD CABLE GLAND BRASS
SEAL MATERIAL CMP SOLO LSF
CABLE TYPE S.W.A., S.T.A. & WIRE BRAID
ARMOUR CLAMPING REVERSIBLE ARMOUR CLAMPINGCONE & BI-DIRECTIONAL CLAMPING RING
SEALING TECHNIQUE CMP UNIQUE COMPENSATINGDISPLACEMENT SEAL (CDS) SYSTEM
SEALING AREA(S) INNER & OUTER SHEATH
ACCESSORIES SHROUD, LOCKNUT, EARTH TAG, SERRATEDWASHER,ADAPTOR / REDUCER,ENTRY THREAD SEAL
* Integral Entry Thread option Available (for this option pre-fixing / and type with ‘R’, e.g. RT3CDS or RT3CDSPB)
M U L T I P L E A R M O U
R C A B L E S
32
All Dimensions in Millimetres
-
8/17/2019 Cat-CMP Cable Gland
35/64
w w w . c m p – p r o d u c t s . c o m
34
Doc Ref : TPC 164 issue 04 2005
A R M O U R E D C A B
L E S W A
33
A
B
C
D
E
Dual Certified Flameproof (Type 'd') and Increased Safety (Type 'e') indoor and outdoor
cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with all
types of SWA cable providing a Flameproof seal on the cable inner sheath and an
environmental seal on the cable outer sheath.The gland also provides mechanical cable
retention and electrical continuity via armour wire termination.
TECHNICAL DATA
TYPE E1FW
CENELEC (ATEX) CERTIFICATION DETAIL SIRA01ATEX1286X, SIRA01ATEX3287X
CODE OF PROTECTION CATEGORY ATEX II 2 GD EEx d IIC & EEx e II,EQUIPMENT ZONE 1, ZONE 2, ZONE 21, &ZONE 22 - GAS GROUPS IIA, IIB, IIC
COMPLIANCE STANDARDS EN50014, EN50018, EN50019, EN50281-1-1
CONTINUOUS OPERATING TEMP. RANGE -60°C TO +130°C
INGRESS PROTECTION IP66
GLAND MATERIAL BRASS
SEAL MATERIAL CMP SOLO LSF
CABLE TYPE STEE