cassi® ii · cs2001-bh cassi® ii rotational core biopsy handle 1 cs2100-nt cassi® ii 10-gauge...

8
Cassi® II Rotational Core Ultrasound Breast Biopsy with Stick-Freeze Technology® Beacon™ Breast Tissue Marker with exceptional visualization Cassi® Star Breast Tissue Marker with exceptional visualisation Breast Biopsy Breast Tissue Markers

Upload: others

Post on 06-Aug-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Cassi® II · CS2001-BH Cassi® II Rotational Core Biopsy Handle 1 CS2100-NT Cassi® II 10-Gauge Needle with Sample Tray 10 CS2120-NT Cassi® II 12-Gauge Needle with Sample Tray 10

Cassi® II Rotational Core Ultrasound Breast Biopsy with Stick-Freeze Technology®

Beacon™ Breast Tissue Marker with exceptional visualization

Cassi® Star Breast Tissue Marker with exceptional visualisation

Breast Biopsy

Breast Tissue Markers

Page 2: Cassi® II · CS2001-BH Cassi® II Rotational Core Biopsy Handle 1 CS2100-NT Cassi® II 10-Gauge Needle with Sample Tray 10 CS2120-NT Cassi® II 12-Gauge Needle with Sample Tray 10

2

Cassi® II Rotational Core Ultrasound Breast BiopsyCassi® II is a hand-held, self-contained biopsy device that provides highly accurate, targeted tissue sampling while delivering more biopsy tissue in fewer passes.

Using ultrasound guidance, the Cassi® II 19-Gauge guide needle is easily maneuvered through breast tissue and positioned precisely through the targeted lesion.

Patented Stick-Freeze Technology® immobilizes the lesion as the 10-Gauge or 12-Gauge rotating cutting cannula advances into the secured tissue.

The result is a large, intact sample of contiguous tissue from the targeted area.

Cassi® II is a versatile device you can rely on for today’s breast

biopsy challenges.

Stick-FreezeTechnology®

No forward throw eliminates the risk of hitting critical structures behind the lesion, such as thorax wall, vessels, implants, etc. Patented Stick Freeze Technology® ensures the target lesion is immobilized and remains fixed to the 19-Gauge guiding needle during the sampling process 19-Gauge guiding needle allows for easy navigation of dense breast tissue Produces large 10-Gauge or 12-Gauge contiguous core samples Cassi® II enables you to biopsy patients with challenging breast lesions of varying tissue density and location

Cassi® II Rotational Core Ultrasound Breast Biopsy

Versatility Works across wide range of lesion types

and locations.

Cassi® II enables you to biopsy patients with challenging breast lesions such as those in dense

breast tissue, fibroadenomas, lesions located against the chest wall, in the axilla, in lymph nodes,

lesions close to breast implants and close to the skin surface.1

In these more challenging cases, Cassi® II’s “No forward-throw” feature helps you easily

and safely collect samples without impacting tissue and structures beyond the lesion.

Cassi® II allows you to navigate around vessels to reach lesions which may minimize bleeding

and tissue trauma.

The low-profile, 19-Gauge guide needle facilitates dense breast tissue navigation while

still producing large 10-Gauge or 12-Gauge cores.

References:1 Tomkovich K, McGinnis M. Outcomes of the Cassi “Stick Freeze” Breast Biopsy System in 69 Patients Using Ultrasound Guidance. Scientic Research Poster Presented at Society of Interventional Radiology Annual Meeting, 2008.

Page 3: Cassi® II · CS2001-BH Cassi® II Rotational Core Biopsy Handle 1 CS2100-NT Cassi® II 10-Gauge Needle with Sample Tray 10 CS2120-NT Cassi® II 12-Gauge Needle with Sample Tray 10

3

Significant Core Samples2

Cassi® II 12-gauge

Cassi® II 10-gauge

* NOTE: One (1) new C02

canister must be used with each

new needle.

Cassi® II 10-Gauge Needle Cassi® II C02 Canister/CapCassi® II 12-Gauge Needle Tray

Cassi® II secures the tissue sample you need every time. The core samples from Cassi®II 10-Gauge and 12-Gauge cannulas provide large amount of tissue, minimizing the number of samples needed for histological examination.

Accuracy Accesses targeted lesion with pinpoint

precision.

Cassi® II’s 19-Gauge guide needle can be precisely placed in the center of the targeted lesion and confirmed under

ultrasound guidance.

Real-time ultrasound confirmation of needle placement in the lesion

prior to sampling eliminates excision of non-targeted breast tissue.

2 Biopsy samples to scale, size not actual, picture magnified.

Item no. Specification Pcs/box

CS2001-BH Cassi® II Rotational Core Biopsy Handle 1

CS2100-NT Cassi® II 10-Gauge Needle with Sample Tray 10

CS2120-NT Cassi® II 12-Gauge Needle with Sample Tray 10

61302-01M Coaxial Needle 8-Gauge (matches CS2100-NT) 10

61303-01M Coaxial Needle 10-Gauge (matches CS2120-NT) 10

CS2001-CC-10 Cassi® II C02 Canister/Caps 10

1030SCI PullUp™ Instrument Cover 10

Cassi® II Rotational Core Ultrasound Breast Biopsy

• Streamlines practice productivity and improves patient’s biopsy experience• Cassi® II’s lightweight design delivers exceptional control for accurate navigation• No capital equipment purchases or service agreements are required• Elegant design, untethered handle and quiet performance of the Cassi® II device may minimize patient anxiety• The large intact and contiguous cores obtained by Cassi® II allow you to achieve concordance with a minimum number of passes

Cassi® II Rotational Core Ultrasound Breast Biopsy • User-Friendly

Cassi® II

Page 4: Cassi® II · CS2001-BH Cassi® II Rotational Core Biopsy Handle 1 CS2100-NT Cassi® II 10-Gauge Needle with Sample Tray 10 CS2120-NT Cassi® II 12-Gauge Needle with Sample Tray 10

4

Beacon™ Breast Tissue Marker The Beacon™ Breast Tissue Marker, due to its non-metal nature, has low MRI artifact compared to metal tissue markers and has low ring-down artifact in Tomosynthesis.

The Beacon™ Breast Tissue Marker is the first marker made of Polyetherketoneketone (PEKK) Polymers, which are used routinely in surgical implants and dental devices.

Proven biocompatibility allows for permanent placement in breast tissue.

The Beacon™ Breast Tissue Marker pairs well with Cassi® II device.

Beacon™ Breast Tissue Marker Permanently visible under - Ultrasound - X-Ray - Mammography - Tomosynthesis - MRI (up to 3.0 Tesla field strength) Designed for safe, reliable and precise placement during core biopsies Unique shape designed to prevent migration Biocompatible composition First marker made of Polyetherketoneketone (PEKK) Polymers

Item no. Marker Size Specification Pcs/box

BM1412-50 1.5 mm x 5 mm Beacon™ Breast Tissue Marker 10

Beacon™Breast Tissue Marker

Placement device: 14-Gauge Length: 12 cm

Page 5: Cassi® II · CS2001-BH Cassi® II Rotational Core Biopsy Handle 1 CS2100-NT Cassi® II 10-Gauge Needle with Sample Tray 10 CS2120-NT Cassi® II 12-Gauge Needle with Sample Tray 10

5

Ultrasound Mammography

MRI Tomosynthesis

The Beacon™ Marker is 1.5 mm x 5 mm

Page 6: Cassi® II · CS2001-BH Cassi® II Rotational Core Biopsy Handle 1 CS2100-NT Cassi® II 10-Gauge Needle with Sample Tray 10 CS2120-NT Cassi® II 12-Gauge Needle with Sample Tray 10

6

Cassi® Star Tissue MarkerThe Cassi® Star Tissue Marker has been developed for enhanced ultrasound visibility. Its star shape, with eight deep cut edges, secures bright reflection of ultrasound waves and is easily distinguished from other breast tissue markers under mammographic imaging.

Due to its non-metal nature, it has low MRI artifact compared to metal tissue markers and has low ring-down artifact in Tomosynthesis.

The Cassi® Star Tissue Marker is made of Polyetherketoneketone (PEKK) Polymers which are used routinely in surgical implants and dental devices.

PEKK provides permanent visibility in all imaging modalities and does not have additional materials that can cause the marker to expand or change form over time.

Proven biocompatibility allows for permanent placement in breast tissue.

Item no. Marker Size Specification Pcs/box

SM1412-50 1.5 mm x 5 mm Cassi® Star Tissue Marker 10

Cassi® Star Tissue Marker

Placement device: 14-Gauge Length: 12 cm

Cassi® Star Tissue Marker Permanent and clear visualization with: - Mammography - Ultrasound - MRI (up to 3.0 Tesla field strength) - Tomosynthesis • Precise placement in lesion since it is a naked marker• Unique star shape designed to prevent migration• Made of Polyetherketoneketone (PEKK) Polymers• Precise placement in lesion since it is a bare marker

Page 7: Cassi® II · CS2001-BH Cassi® II Rotational Core Biopsy Handle 1 CS2100-NT Cassi® II 10-Gauge Needle with Sample Tray 10 CS2120-NT Cassi® II 12-Gauge Needle with Sample Tray 10

7

Ultrasound Ultrasound

MRI Mammography

The Cassi® Star Tissue Marker is 1.5 mm x 5 mm

Page 8: Cassi® II · CS2001-BH Cassi® II Rotational Core Biopsy Handle 1 CS2100-NT Cassi® II 10-Gauge Needle with Sample Tray 10 CS2120-NT Cassi® II 12-Gauge Needle with Sample Tray 10

Mermaid Medical Inc. 7340 South Alton Way, Ste 11-H ∙ Centennial CO ∙ 80112 ∙ USA

[email protected] • www.mermaidmedical.comToll Free: (855) 427-6799 ∙ Ph: (720) 420-9999 ∙ Fax: (720) 920-9579

Denmark Tel: +45 47 10 85 70Fax: +45 47 10 85 71

[email protected]

FinlandTel: +358 923 11 32 38Fax: +358 923 11 32 39

[email protected]

Germany Tel: +49 40 8518665-0Fax: +49 40 8518665-1

[email protected]

ItalyTel: +39 010 868 16 13Fax: +39 010 863 07 33

[email protected]

NetherlandsTel: +31 314 63 2070Fax: +31 314 63 1685

[email protected]

Norway & Iceland Tel: +47 21 53 88 94Fax: +47 21 53 88 95

[email protected]

SwedenTel: +46 31 755 41 28Fax: +46 31 755 45 99

[email protected]

SpainTel: +34 925 717 378Fax: +34 925 049 112

[email protected]

United KingdomTel: +44 (0) 1704 560493Fax: +44 (0) 1704 551182

[email protected]

Breast Biopsy